SynGap Missense Server

Table of SynGAP1 Isoform α2 (UniProt Q96PV0-1) Missense Variants.

c.dna Variant SGM Consensus Domain and Structure information: based on WT protein Annotated databases Deep learning-based pathogenicity predictions Folding stability-based pathogenicity predictions Sequence/structure-based pathogenicity predictions Phase Separation Evolutionary/physical properties Molecular Dynamics-based analysis DOI
Domain IUPred2 ANCHOR2 AlphaFold MobiDB PhosphoSitePlus ClinVar gnomAD ESM1b AlphaMissense FoldX Rosetta Foldetta PremPS REVEL PROVEAN PolyPhen-2 HumDiv PolyPhen-2 HumVar FATHMM SIFT PSMutPred PAM Physical SASA Normalized B-factor backbone Normalized B-factor sidechain SynGAP Structural Annotation
Score Prediction Score Prediction pLDDT disorder disorder LTP HTP KL PTM Clinical Status Review Subm. ID Allele count Allele freq. LLR score Prediction Pathogenicity Class Optimized Average ΔΔG Prediction StdDev ΔΔG Prediction ΔΔG Prediction ΔΔG Prediction Score Prediction Score Prediction pph2_prob Prediction pph2_prob Prediction Nervous System Score Prediction Prediction Status Conservation Sequences IP RF SP RF Prediction PAM250 PAM120 Hydropathy Δ MW Δ Average Δ Δ StdDev Δ StdDev Secondary Tertiary bonds Inside out GAP-Ras interface At membrane No effect MD Alert Verdict Description
c.213C>G
D71E
2D
AIThe SynGAP1 missense variant D71E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic call comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign verdict. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are not available. Overall, the consensus of the available predictions points to a benign impact, and this is consistent with the lack of ClinVar evidence or population data. Thus, the variant is most likely benign, and this assessment does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.575842Disordered0.456046Uncertain0.3500.7990.375-3.276Likely Benign0.134Likely BenignLikely Benign0.079Likely Benign-0.28Neutral0.000Benign0.000Benign4.39Benign0.00Affected0.14900.5922320.014.03
c.2647C>G
L883V
2D
AIThe SynGAP1 missense variant L883V is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification—there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.716283Disordered0.641952Binding0.3340.8860.250-4.075Likely Benign0.079Likely BenignLikely Benign0.059Likely Benign-0.28Neutral0.451Benign0.157Benign2.67Benign0.28Tolerated0.16110.3744210.4-14.03
c.2828G>A
G943D
2D
AIThe SynGAP1 missense variant G943D is not reported in ClinVar and is absent from gnomAD. In silico predictors that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; ESM1b is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Taken together, the overwhelming majority of predictions indicate a benign effect, and this conclusion does not contradict any ClinVar status (none is assigned). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.973328Disordered0.860437Binding0.3720.9100.750-7.951In-Between0.304Likely BenignLikely Benign0.296Likely Benign-0.28Neutral0.224Benign0.113Benign2.85Benign0.11Tolerated0.19040.28261-1-3.158.04
c.2975T>G
V992G
2D
AIThe SynGAP1 missense variant V992G is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). All available in silico predictors classify the variant as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity, so the benign group includes every listed predictor, while the pathogenic group is empty. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign; the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields a benign verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence overwhelmingly supports a benign effect, and this conclusion does not contradict any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.754692Disordered0.921728Binding0.3310.9170.750-1.906Likely Benign0.080Likely BenignLikely Benign0.067Likely Benign-0.28Neutral0.056Benign0.086Benign4.21Benign0.16Tolerated0.21140.2612-1-3-4.6-42.08
c.3149G>A
G1050E
2D
AIThe SynGAP1 missense variant G1050E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect. There is no ClinVar entry to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.906802Binding0.3700.9280.875-8.175Likely Pathogenic0.266Likely BenignLikely Benign0.071Likely Benign-0.28Neutral0.411Benign0.171Benign2.50Benign0.08Tolerated0.14180.42580-2-3.172.06
c.3166G>A
G1056S
2D
AIThe SynGAP1 missense variant G1056S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.868632Binding0.4020.9350.875-5.252Likely Benign0.080Likely BenignLikely Benign0.339Likely Benign-0.28Neutral0.451Benign0.149Benign1.87Pathogenic0.55Tolerated0.24970.570210-0.430.03
c.3191A>G
Q1064R
2D
AIThe SynGAP1 missense variant Q1064R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and there is no conflict with ClinVar status because the variant is not yet classified there. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875-2.981Likely Benign0.202Likely BenignLikely Benign0.143Likely Benign-0.28Neutral0.586Possibly Damaging0.159Benign4.19Benign0.16Tolerated0.22570.365411-1.028.06
c.32G>C
G11A
2D
AIThe SynGAP1 missense variant G11A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.444081Structured0.501027Binding0.3480.9150.375-3.611Likely Benign0.106Likely BenignLikely Benign0.072Likely Benign-0.28Neutral0.105Benign0.007Benign4.00Benign0.00Affected0.40450.5440102.214.03
c.3376G>A
G1126S
2D
AIThe SynGAP1 missense variant G1126S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also predicts Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence points to a benign impact for G1126S, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.894241Disordered0.837209Binding0.3450.9180.875-5.004Likely Benign0.077Likely BenignLikely Benign0.268Likely Benign-0.28Neutral0.611Possibly Damaging0.171Benign4.78Benign0.74Tolerated0.25090.530010-0.430.03
c.3692G>A
S1231N
2D
AIThe SynGAP1 missense variant S1231N is predicted to be benign by all available in‑silico tools. Consensus predictors such as REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a “Likely Benign” status. No tool predicts pathogenicity, so the pathogenic‑prediction group is empty. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. ClinVar contains no entry for this variant, and it is not present in gnomAD. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.490133Structured0.519419Binding0.8760.5440.250-3.443Likely Benign0.151Likely BenignLikely Benign0.068Likely Benign-0.28Neutral0.002Benign0.005Benign2.67Benign0.19Tolerated0.09540.333011-2.727.03
c.3775A>G
I1259V
2D
AIThe SynGAP1 I1259V missense change is not reported in ClinVar and has no gnomAD entry. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as “Uncertain,” SGM‑Consensus as “Likely Benign,” and Foldetta (combining FoldX‑MD and Rosetta) has no available result. Overall, the balance of evidence leans toward a benign interpretation, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.494003Structured0.576405Binding0.8850.5740.250-3.670Likely Benign0.892Likely PathogenicAmbiguous0.171Likely Benign-0.28Neutral0.958Probably Damaging0.970Probably Damaging2.67Benign0.08Tolerated0.09570.290243-0.3-14.03
c.901G>T
A301S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A301S is not reported in ClinVar and is absent from gnomAD. Prediction tools that assess sequence conservation and functional impact uniformly indicate a benign effect: SGM‑Consensus (Likely Benign), REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only two tools, polyPhen‑2 HumDiv and HumVar, predict a pathogenic outcome. High‑accuracy methods corroborate the benign consensus: AlphaMissense‑Optimized scores benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) also reports benign. No evidence from these analyses suggests a deleterious effect. Therefore, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.429200Structured0.258424Uncertain0.6470.2720.375-2.488Likely Benign0.066Likely BenignLikely Benign0.20Likely Benign0.1-0.32Likely Benign-0.06Likely Benign0.22Likely Benign0.151Likely Benign-0.28Neutral0.992Probably Damaging0.983Probably Damaging4.21Benign0.13Tolerated0.27060.602211-2.616.00
c.153C>G
I51M
2D
AIThe SynGAP1 missense variant I51M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic call comes from SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as likely benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, SGM‑Consensus indicates likely benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Based on the collective predictions, the I51M substitution is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.291804Structured0.454181Uncertain0.6060.7100.000-4.732Likely Benign0.381AmbiguousLikely Benign0.093Likely Benign-0.27Neutral0.099Benign0.075Benign4.13Benign0.00Affected0.07640.328121-2.618.03
c.190A>C
I64L
2D
AIThe SynGAP1 missense variant I64L is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus indicates Likely Benign, and Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for I64L, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.422041Structured0.475481Uncertain0.4780.7470.125-2.498Likely Benign0.437AmbiguousLikely Benign0.087Likely Benign-0.27Neutral0.010Benign0.001Benign4.13Benign0.00Affected0.06280.303022-0.70.00
c.190A>T
I64L
2D
AIThe SynGAP1 missense variant I64L is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus indicates Likely Benign, and Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.422041Structured0.475481Uncertain0.4780.7470.125-2.498Likely Benign0.437AmbiguousLikely Benign0.087Likely Benign-0.27Neutral0.010Benign0.001Benign4.13Benign0.00Affected0.06280.303022-0.70.00
c.2221C>T
P741S
2D
AIThe SynGAP1 missense variant P741S is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33441686‑C‑T). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. Grouping by consensus, the benign‑predicting tools outnumber the pathogenic one. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” No Foldetta stability data are available, so it does not influence the conclusion. Overall, the computational evidence indicates that the variant is most likely benign, and this assessment does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.885302Disordered0.493550Uncertain0.3540.8590.875Uncertain 26-33441686-C-T31.86e-6-3.700Likely Benign0.063Likely BenignLikely Benign0.076Likely Benign-0.27Neutral0.270Benign0.136Benign2.92Benign0.00Affected4.3220.28880.42781-10.8-10.0410.1016/j.ajhg.2020.11.011
c.225G>C
E75D
2D
AIThe SynGAP1 missense variant E75D is reported in gnomAD (6‑33425833‑G‑C) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is “Likely Benign.” No Foldetta stability prediction is available. Overall, the preponderance of evidence indicates that E75D is most likely benign, and this conclusion is not contradicted by ClinVar status, which is currently absent.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.595080Disordered0.443881Uncertain0.3030.8220.5006-33425833-G-C16.20e-7-3.710Likely Benign0.073Likely BenignLikely Benign0.058Likely Benign-0.27Neutral0.001Benign0.000Benign4.25Benign0.00Affected4.3210.20260.3833230.0-14.03
c.225G>T
E75D
2D
AIThe SynGAP1 missense variant E75D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.595080Disordered0.443881Uncertain0.3030.8220.500-3.710Likely Benign0.073Likely BenignLikely Benign0.058Likely Benign-0.27Neutral0.001Benign0.000Benign4.25Benign0.00Affected4.3210.20260.3833230.0-14.03
c.2262G>C
E754D
2D
AIThe SynGAP1 missense variant E754D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.505461Disordered0.750531Binding0.3570.8720.500-2.360Likely Benign0.065Likely BenignLikely Benign0.076Likely Benign-0.27Neutral0.002Benign0.007Benign2.53Benign0.45Tolerated0.17250.3983320.0-14.03
c.2262G>T
E754D
2D
AIThe SynGAP1 missense variant E754D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this trend: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on current predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.505461Disordered0.750531Binding0.3570.8720.500-2.360Likely Benign0.065Likely BenignLikely Benign0.076Likely Benign-0.27Neutral0.002Benign0.007Benign2.53Benign0.45Tolerated0.17250.3983320.0-14.03
c.2398G>C
G800R
2D
AIThe SynGAP1 missense variant G800R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.852992Disordered0.588350Binding0.3030.8840.625-3.613Likely Benign0.405AmbiguousLikely Benign0.147Likely Benign-0.27Neutral0.003Benign0.004Benign2.84Benign0.17Tolerated0.08680.3835-3-2-4.199.14
c.241C>A
L81M
2D
AIThe SynGAP1 missense variant L81M is listed in ClinVar with no submitted interpretation and is present in gnomAD (variant ID 6‑33425849‑C‑A). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; no Foldetta stability result is available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which remains unclassified.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.632174Disordered0.502033Binding0.2910.8780.2506-33425849-C-A16.20e-7-5.351Likely Benign0.254Likely BenignLikely Benign0.039Likely Benign-0.27Neutral0.789Possibly Damaging0.165Benign3.95Benign0.00Affected4.3210.06920.243224-1.918.03
c.2636C>A
A879E
2D
AIThe SynGAP1 missense variant A879E is reported in gnomAD (variant ID 6‑33443188‑C‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. High‑accuracy predictions specifically show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta data is missing. Overall, the majority of evidence points to a benign effect, and this assessment does not contradict any ClinVar status because none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.608892Disordered0.622695Binding0.2770.8740.2506-33443188-C-A16.20e-7-3.786Likely Benign0.503AmbiguousLikely Benign0.070Likely Benign-0.27Neutral0.872Possibly Damaging0.659Possibly Damaging2.70Benign0.27Tolerated3.7750.11200.1903-10-5.358.04
c.2765G>A
R922Q
2D
AIThe SynGAP1 missense variant R922Q is listed in ClinVar as Benign (ClinVar ID 2917638.0) and is present in gnomAD (ID 6‑33443317‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (derived from the same set of high‑confidence predictors) also as benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, aligning with the ClinVar classification and indicating no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.549308Disordered0.955308Binding0.2770.8450.375Benign 16-33443317-G-A74.34e-6-3.295Likely Benign0.189Likely BenignLikely Benign0.085Likely Benign-0.27Neutral0.992Probably Damaging0.736Possibly Damaging2.57Benign0.20Tolerated3.7750.34440.2602111.0-28.06
c.2897A>C
H966P
2D
AIThe SynGAP1 missense variant H966P is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.750-5.831Likely Benign0.064Likely BenignLikely Benign0.279Likely Benign-0.27Neutral0.001Benign0.001Benign4.01Benign0.72Tolerated0.21680.43010-21.6-40.02
c.3233T>C
V1078A
2D
AIThe SynGAP1 missense variant V1078A is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools largely agree on a benign effect: SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict benign. Only two tools predict pathogenicity: SIFT and AlphaMissense‑Default. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign. No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the majority of predictions indicate that V1078A is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.986989Binding0.2940.8980.750-2.794Likely Benign0.690Likely PathogenicLikely Benign0.089Likely Benign-0.27Neutral0.011Benign0.006Benign3.94Benign0.02Affected0.26790.254600-2.4-28.05
c.3358G>A
G1120S
2D
AIThe SynGAP1 missense variant G1120S is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions strongly suggests that G1120S is most likely benign, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.871313Disordered0.804931Binding0.3350.9250.875-4.959Likely Benign0.073Likely BenignLikely Benign0.286Likely Benign-0.27Neutral0.451Benign0.209Benign3.69Benign0.77Tolerated0.25150.531110-0.430.03
c.3418A>T
T1140S
2D
AIThe SynGAP1 missense variant T1140S is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.708094Binding0.2930.8541.000-2.805Likely Benign0.105Likely BenignLikely Benign0.052Likely Benign-0.27Neutral0.025Benign0.010Benign3.25Benign0.91Tolerated0.34010.350411-0.1-14.03
c.3589G>A
E1197K
2D
AIThe SynGAP1 E1197K missense change is not reported in ClinVar and has no gnomAD entry. Functional prediction tools that agree on benign impact include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while pathogenic predictions come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, AlphaMissense‑Default, and AlphaMissense‑Optimized. The high‑accuracy consensus (SGM‑Consensus) classifies the variant as Likely Benign, whereas AlphaMissense‑Optimized predicts it to be Pathogenic; Foldetta stability analysis is unavailable. Overall, the majority of evidence points toward a benign effect, though the single high‑accuracy pathogenic prediction introduces uncertainty. The variant is most likely benign based on the current predictions, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.613573Disordered0.437361Uncertain0.8270.5990.250-5.048Likely Benign0.958Likely PathogenicLikely Pathogenic0.364Likely Benign-0.27Neutral0.999Probably Damaging0.995Probably Damaging5.45Benign0.45Tolerated0.15120.542401-0.4-0.94
c.3674C>G
S1225C
2D
AIThe SynGAP1 missense variant S1225C is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only two tools, polyPhen‑2 HumDiv and HumVar, predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is also benign. Foldetta results are not available for this variant. Overall, the preponderance of evidence indicates that S1225C is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.513880Disordered0.441915Uncertain0.8910.5440.500-6.494Likely Benign0.103Likely BenignLikely Benign0.306Likely Benign-0.27Neutral0.975Probably Damaging0.870Possibly Damaging5.35Benign0.15Tolerated0.06690.48420-13.316.06
c.3892C>A
Q1298K
2D
AIThe SynGAP1 missense variant Q1298K is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is not contradicted by any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.823549Disordered0.895297Binding0.4100.8210.750-3.415Likely Benign0.228Likely BenignLikely Benign0.138Likely Benign-0.27Neutral0.000Benign0.002Benign2.86Benign0.24Tolerated0.13600.290311-0.40.04
c.40C>A
P14T
2D
AIThe SynGAP1 missense variant P14T is reported in gnomAD (ID 6‑33420304‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus also reports likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign impact for P14T, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.433034Structured0.471596Uncertain0.3990.9090.3756-33420304-C-A-3.261Likely Benign0.150Likely BenignLikely Benign0.078Likely Benign-0.27Neutral0.212Benign0.014Benign4.20Benign0.00Affected4.3210.19120.6658-100.93.99
c.41C>A
P14H
2D
AIThe SynGAP1 missense variant P14H is listed in gnomAD (ID 6‑33420305‑C‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no reported result for this variant, so its status is unavailable. Overall, the majority of predictions—including the high‑accuracy tools—indicate that P14H is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.433034Structured0.471596Uncertain0.3990.9090.3756-33420305-C-A-3.747Likely Benign0.231Likely BenignLikely Benign0.171Likely Benign-0.27Neutral0.742Possibly Damaging0.091Benign4.15Benign0.00Affected4.3210.19990.5176-20-1.640.02
c.1130T>A
M377K
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M377K is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are Rosetta and Foldetta. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome, while premPS remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as pathogenic. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the absence of a ClinVar classification. Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.675549Disordered0.431183Uncertain0.3240.8840.625-3.718Likely Benign0.226Likely BenignLikely Benign0.20Likely Benign0.24.44Destabilizing2.32Destabilizing0.62Ambiguous0.440Likely Benign-0.26Neutral0.002Benign0.003Benign5.46Benign0.07Tolerated0.24230.16710-1-5.8-3.02
c.1153T>C
S385P
2D
3DClick to see structure in 3D Viewer
AISynGAP1 variant S385P is listed in ClinVar with an uncertain significance and is present in gnomAD (variant ID 6-33438058‑T‑C). Prediction tools that classify the variant as benign include REVEL, Foldetta, premPS, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict pathogenicity are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. Predictions from FoldX and Rosetta are inconclusive. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as benign. Overall, the majority of computational evidence supports a benign effect, which is consistent with the ClinVar uncertain status and does not contradict it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.733139Disordered0.425480Uncertain0.3410.9250.750Uncertain 16-33438058-T-C-5.431Likely Benign0.123Likely BenignLikely Benign0.91Ambiguous0.6-0.90Ambiguous0.01Likely Benign0.19Likely Benign0.385Likely Benign-0.26Neutral0.676Possibly Damaging0.693Possibly Damaging4.63Benign0.04Affected4.3230.29250.68051-1-0.810.04210.318.51.80.90.30.0UncertainSer385 is located in the Gly-rich Ω loop (res. Pro364-Pro398) between two anti-parallel β sheet strands (res. Thr359-Pro364, res. Ala399-Ile411). Because the Ω loop is assumed to directly interact with the membrane, it moves arbitrarily throughout the WT solvent simulations. The Ω loop potentially plays a crucial role in the SynGAP-membrane complex association, stability, and dynamics. However, this aspect cannot be fully addressed through solvent simulations alone.Ω loops are known to play major roles in protein functions that require flexibility, and so they are rich in glycine residues, prolines, and, to a lesser extent, small hydrophilic residues to ensure maximum flexibility. Thus, the variant’s Pro385 is potentially tolerated in the Ω loop. However, since the effects on Gly-rich Ω loop dynamics can only be well studied through the SynGAP-membrane complex, no definite conclusions can be drawn.
c.1165T>A
S389T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S389T is not reported in ClinVar and is present in gnomAD (variant ID 6‑33438070‑T‑A). Functional prediction tools that converge on a benign outcome include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 HumDiv, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 HumVar and SIFT predict a pathogenic effect. The high‑accuracy consensus methods reinforce the benign assessment: AlphaMissense‑Optimized is benign; the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also reports a benign outcome. Taken together, the majority of evidence supports a benign classification for S389T, and this conclusion is consistent with the absence of a ClinVar pathogenic report.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.703578Disordered0.417444Uncertain0.3060.8030.8756-33438070-T-A-5.403Likely Benign0.089Likely BenignLikely Benign0.36Likely Benign0.20.11Likely Benign0.24Likely Benign-0.04Likely Benign0.242Likely Benign-0.26Neutral0.140Benign0.481Possibly Damaging5.07Benign0.03Affected4.3280.23170.6656110.114.03
c.19T>A
S7T
2D
AIThe SynGAP1 missense variant S7T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.590140Disordered0.548467Binding0.3860.9220.750-4.182Likely Benign0.110Likely BenignLikely Benign0.101Likely Benign-0.26Neutral0.024Benign0.007Benign4.13Benign0.00Affected0.16880.5919110.114.03
c.2315T>C
F772S
2D
AIThe SynGAP1 missense variant F772S is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority of other predictors (polyPhen‑2 HumDiv and HumVar) suggest pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign and the SGM‑Consensus likewise indicates Likely Benign; Foldetta data are not available. Overall, the preponderance of evidence points to a benign effect for F772S, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.450668Structured0.922662Binding0.3290.8840.250-2.722Likely Benign0.442AmbiguousLikely Benign0.138Likely Benign-0.26Neutral0.845Possibly Damaging0.899Possibly Damaging4.21Benign0.56Tolerated0.41340.0558-3-2-3.6-60.10
c.2446T>C
S816P
2D
AIThe SynGAP1 missense variant S816P is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority of other predictors (polyPhen‑2 HumDiv and HumVar) suggest pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign and the SGM‑Consensus likewise indicates Likely Benign; Foldetta data are unavailable. Overall, the preponderance of evidence points to a benign effect for S816P, and this conclusion is not in conflict with ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.476583Structured0.747189Binding0.3470.8980.375-3.662Likely Benign0.510AmbiguousLikely Benign0.160Likely Benign-0.26Neutral0.999Probably Damaging0.966Probably Damaging2.66Benign0.45Tolerated0.22980.51021-1-0.810.04
c.2635G>T
A879S
2D
AIThe SynGAP1 missense variant A879S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also predicts Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence supports a benign classification, and this is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.608892Disordered0.622695Binding0.2770.8740.250-3.406Likely Benign0.086Likely BenignLikely Benign0.091Likely Benign-0.26Neutral0.580Possibly Damaging0.324Benign2.68Benign0.44Tolerated0.24690.526611-2.616.00
c.2647C>A
L883I
2D
AIThe SynGAP1 missense variant L883I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.716283Disordered0.641952Binding0.3340.8860.250-5.046Likely Benign0.102Likely BenignLikely Benign0.049Likely Benign-0.26Neutral0.802Possibly Damaging0.355Benign2.66Benign0.35Tolerated0.09700.4093220.70.00
c.2717T>G
L906R
2D
AIThe SynGAP1 missense variant L906R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. The SGM Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (2 benign vs 2 pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of standard predictors (5 vs 4) lean toward pathogenicity, while the high‑accuracy AlphaMissense‑Optimized predicts benign and the consensus remains unresolved. Thus, the variant is most likely pathogenic based on the current predictions, and this assessment does not contradict any ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.604312Disordered0.644316Binding0.3150.9200.250-3.440Likely Benign0.769Likely PathogenicLikely Benign0.160Likely Benign-0.26Neutral1.000Probably Damaging0.990Probably Damaging2.18Pathogenic0.04Affected0.12280.0947-3-2-8.343.03
c.2720G>A
S907N
2D
AIThe SynGAP1 missense variant S907N is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority‑vote SGM‑Consensus also reports a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy evaluations further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is likely benign, with no Foldetta data to contradict this. Overall, the preponderance of evidence points to a benign effect, and this assessment does not conflict with any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.637480Disordered0.661854Binding0.3360.9200.250-4.520Likely Benign0.430AmbiguousLikely Benign0.140Likely Benign-0.26Neutral0.951Possibly Damaging0.803Possibly Damaging2.66Benign0.08Tolerated0.13120.458511-2.727.03
c.2936T>A
F979Y
2D
AIThe SynGAP1 missense variant F979Y is not reported in ClinVar and is absent from gnomAD. All available in‑silico predictors classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence strongly supports a benign impact, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.977500Binding0.2740.8890.625-3.420Likely Benign0.277Likely BenignLikely Benign0.123Likely Benign-0.26Neutral0.451Benign0.285Benign4.18Benign0.06Tolerated0.14510.284373-4.116.00
c.3161G>A
G1054D
2D
AISynGAP1 missense variant G1054D is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized scores benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence indicates the variant is most likely benign, which does not contradict the current ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.983019Disordered0.878015Binding0.3890.9360.875Uncertain 1-10.385Likely Pathogenic0.351AmbiguousLikely Benign0.279Likely Benign-0.26Neutral0.818Possibly Damaging0.266Benign4.07Benign0.37Tolerated3.7750.18240.20351-1-3.158.04
c.3217T>A
S1073T
2D
AIThe SynGAP1 missense variant S1073T is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.916840Disordered0.985818Binding0.3130.9050.750-5.203Likely Benign0.169Likely BenignLikely Benign0.161Likely Benign-0.26Neutral0.025Benign0.026Benign4.06Benign0.55Tolerated0.16960.6509110.114.03
c.3383G>C
G1128A
2D
AIThe SynGAP1 missense variant G1128A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.896620Disordered0.865136Binding0.3090.9110.875-5.015Likely Benign0.081Likely BenignLikely Benign0.209Likely Benign-0.26Neutral0.009Benign0.008Benign4.47Benign0.46Tolerated0.35880.5252102.214.03
c.3397A>C
I1133L
2D
AIThe SynGAP1 missense variant I1133L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that I1133L is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.832785Binding0.3160.8920.750-1.147Likely Benign0.107Likely BenignLikely Benign0.202Likely Benign-0.26Neutral0.000Benign0.001Benign5.48Benign0.23Tolerated0.09110.430222-0.70.00
c.370G>A
A124T
2D
AIThe SynGAP1 missense variant A124T is reported in gnomAD (6-33432235‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv flags it as pathogenic, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus itself is benign; Foldetta results are unavailable. Taken together, the preponderance of evidence points to a benign impact. This conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.509769Disordered0.699139Binding0.3400.8830.7506-33432235-G-A16.20e-7-3.551Likely Benign0.101Likely BenignLikely Benign0.046Likely Benign-0.26Neutral0.734Possibly Damaging0.187Benign4.17Benign0.78Tolerated3.6150.18280.768001-2.530.03
c.3976C>A
P1326T
2D
AIThe SynGAP1 missense variant P1326T is reported in gnomAD (ID 6‑33451850‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports a benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT predict a pathogenic impact. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority of the same four high‑accuracy tools) is benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates that P1326T is most likely benign, and this assessment does not contradict any ClinVar classification because no ClinVar variant is listed.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.887377Binding0.3930.7820.8756-33451850-C-A-5.755Likely Benign0.117Likely BenignLikely Benign0.135Likely Benign-0.26Neutral0.999Probably Damaging0.992Probably Damaging3.71Benign0.00Affected3.7750.19550.5517-100.93.99
c.83C>G
S28C
2D
AIThe SynGAP1 missense variant S28C is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.545602Disordered0.438157Uncertain0.3540.8840.125-4.800Likely Benign0.107Likely BenignLikely Benign0.021Likely Benign-0.26Neutral0.022Benign0.004Benign4.13Benign0.11Tolerated0.13870.57410-13.316.06
c.158G>A
G53E
2D
AIThe SynGAP1 missense variant G53E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as “Uncertain” and the SGM‑Consensus as “Likely Benign”; Foldetta results are not available. Overall, the majority of evidence points toward a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign based on current predictive data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.268042Structured0.460894Uncertain0.3860.6660.000-2.061Likely Benign0.853Likely PathogenicAmbiguous0.198Likely Benign-0.25Neutral0.994Probably Damaging0.986Probably Damaging4.29Benign0.00Affected0.14130.43780-2-3.172.06
c.2149C>G
L717V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L717V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Two tools predict a damaging effect: polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Stability‑based methods (FoldX, Rosetta, Foldetta) return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as Likely Benign, and Foldetta as inconclusive. Taken together, the majority of evidence points to a benign impact. This conclusion is consistent with the absence of a ClinVar assertion, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.239899Structured0.429342Uncertain0.9690.3970.000-6.164Likely Benign0.308Likely BenignLikely Benign1.53Ambiguous0.01.25Ambiguous1.39Ambiguous0.09Likely Benign0.119Likely Benign-0.25Neutral0.995Probably Damaging0.970Probably Damaging3.38Benign0.51Tolerated0.12260.2489210.4-14.03
c.2696T>C
I899T
2D
AIThe SynGAP1 missense variant I899T is not reported in ClinVar (ClinVar ID None) but is present in gnomAD (ID 6‑33443248‑T‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.443727Uncertain0.2920.9280.3756-33443248-T-C21.24e-6-2.472Likely Benign0.521AmbiguousLikely Benign0.103Likely Benign-0.25Neutral0.245Benign0.096Benign2.75Benign0.01Affected4.3240.10060.1014-10-5.2-12.05
c.2860C>T
P954S
2D
AIThe SynGAP1 missense variant P954S is listed in ClinVar as Benign (ClinVar ID 833606.0) and is present in gnomAD (ID 6‑33443412‑C‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, which is consistent with the ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984159Disordered0.932268Binding0.4650.9260.750Likely Benign 16-33443412-C-T16.20e-7-3.525Likely Benign0.062Likely BenignLikely Benign0.143Likely Benign-0.25Neutral0.954Possibly Damaging0.812Possibly Damaging2.87Benign1.00Tolerated3.7750.30880.56191-10.8-10.04
c.3158G>C
S1053T
2D
AIThe SynGAP1 missense variant S1053T is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts it as pathogenic, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the preponderance of evidence points to a benign impact for S1053T, and this conclusion is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.875-6.209Likely Benign0.076Likely BenignLikely Benign0.223Likely Benign-0.25Neutral0.625Possibly Damaging0.249Benign5.32Benign0.70Tolerated0.20550.5976110.114.03
c.3167G>C
G1056A
2D
AIThe SynGAP1 missense variant G1056A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while ESM1b remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign consensus (2 benign vs. 1 pathogenic, with one uncertain). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988291Disordered0.868632Binding0.4020.9350.875-7.458In-Between0.086Likely BenignLikely Benign0.325Likely Benign-0.25Neutral0.264Benign0.097Benign1.85Pathogenic0.49Tolerated0.33250.4957102.214.03
c.3430T>A
L1144M
2D
AIThe SynGAP1 missense variant L1144M is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: **benign** – REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized; **pathogenic** – polyPhen‑2 (HumDiv and HumVar) and SIFT. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports Likely Benign. Foldetta predictions are unavailable. Overall, the majority of evidence points to a benign effect for L1144M, and this conclusion does not conflict with ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.726803Binding0.2770.8401.000-4.787Likely Benign0.199Likely BenignLikely Benign0.277Likely Benign-0.25Neutral0.999Probably Damaging0.979Probably Damaging5.38Benign0.05Affected0.08460.386342-1.918.03
c.361G>A
A121T
2D
AIThe SynGAP1 missense variant A121T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. The prediction is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.779859Disordered0.661304Binding0.3620.8880.750-3.955Likely Benign0.070Likely BenignLikely Benign0.059Likely Benign-0.25Neutral0.063Benign0.026Benign4.10Benign0.05Affected0.17920.730510-2.530.03
c.475A>G
I159V
2D
AIThe SynGAP1 I159V missense variant is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign consensus (2 benign vs. 1 pathogenic, with one uncertain). Foldetta results are unavailable. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.454136Structured0.529953Binding0.2780.7310.125-9.714Likely Pathogenic0.384AmbiguousLikely Benign0.113Likely Benign-0.25Neutral0.803Possibly Damaging0.847Possibly Damaging3.98Benign0.00Affected0.11110.273643-0.3-14.03
c.47T>G
M16R
2D
AIThe SynGAP1 missense variant M16R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic call comes from SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as likely benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus also indicates likely benign, and no Foldetta stability data are available. Taken together, the preponderance of evidence supports a benign classification for M16R, and this conclusion does not conflict with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.440853Structured0.459925Uncertain0.3460.9080.375-1.475Likely Benign0.485AmbiguousLikely Benign0.191Likely Benign-0.25Neutral0.014Benign0.003Benign4.21Benign0.00Affected0.19920.10930-1-6.424.99
c.58C>T
P20S
2D
AIThe SynGAP1 missense variant P20S is reported in gnomAD (ID 6‑33420322‑C‑T) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from the four benign‑oriented tools). Pathogenic predictions come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from both general and high‑accuracy predictors points to a benign effect for P20S, and this conclusion is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.529623Disordered0.442804Uncertain0.4480.8990.5006-33420322-C-T-3.054Likely Benign0.153Likely BenignLikely Benign0.076Likely Benign-0.25Neutral0.909Possibly Damaging0.641Possibly Damaging4.30Benign0.00Affected4.3210.37320.5920-110.8-10.04
c.70G>A
V24I
2D
AIThe SynGAP1 missense variant V24I is listed in ClinVar with an “Uncertain” status and is present in gnomAD (variant ID 6-33423479-G-A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Taken together, the overwhelming majority of computational evidence supports a benign impact for V24I, and this conclusion does not contradict the ClinVar designation, which remains uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.541878Disordered0.438970Uncertain0.3820.8900.500Uncertain 16-33423479-G-A95.58e-6-3.701Likely Benign0.137Likely BenignLikely Benign0.069Likely Benign-0.25Neutral0.043Benign0.031Benign3.96Benign0.00Affected4.3210.08440.4564340.314.03
c.901G>A
A301T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A301T is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33437806‑G‑A). Prediction tools that uniformly indicate a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, is benign. Overall, the majority of evidence points to a benign effect, and this is not in conflict with the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.429200Structured0.258424Uncertain0.6470.2720.375Uncertain 56-33437806-G-A21.24e-6-3.448Likely Benign0.070Likely BenignLikely Benign0.36Likely Benign0.2-0.33Likely Benign0.02Likely Benign0.03Likely Benign0.150Likely Benign-0.25Neutral0.997Probably Damaging0.989Probably Damaging4.15Benign0.22Tolerated4.32140.13620.720110-2.530.03219.8-42.8-0.10.0-0.50.2UncertainThe methyl group of Ala301, located in a β hairpin loop linking two anti-parallel β sheet strands (res. Met289-Pro298, res. Thr305-Asn315), points outward from the β hairpin loop, and its backbone atoms do not participate in the loop formation in the WT simulations. In the variant simulations, the hydroxyl group of the Thr301 side chain also mostly points outward; however, the guanidinium group of Arg299 is moved away from its central hairpin loop position.β hairpins are potential nucleation sites during the initial stages of protein folding, so even minor changes in them could be significant. Due to its location near the membrane surface, the residue swap could also affect the C2 loop dynamics and SynGAP-membrane association. However, this is beyond the scope of the solvent-only simulations to unravel.
c.148A>G
I50V
2D
AIThe SynGAP1 missense variant I50V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus methods also support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence indicates that I50V is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.295083Structured0.449965Uncertain0.5450.7080.000-1.051Likely Benign0.141Likely BenignLikely Benign0.082Likely Benign-0.24Neutral0.000Benign0.001Benign4.18Benign0.00Affected0.10910.315943-0.3-14.03
c.151A>G
I51V
2D
AIThe SynGAP1 missense variant I51V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. The variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.291804Structured0.454181Uncertain0.6060.7100.000-3.397Likely Benign0.195Likely BenignLikely Benign0.065Likely Benign-0.24Neutral0.004Benign0.007Benign4.26Benign0.00Affected0.13300.360243-0.3-14.03
c.20C>T
S7F
2D
AIThe SynGAP1 missense variant S7F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus, SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. AlphaMissense‑Optimized independently predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.590140Disordered0.548467Binding0.3860.9220.750-4.346Likely Benign0.250Likely BenignLikely Benign0.171Likely Benign-0.24Neutral0.296Benign0.032Benign4.06Benign0.00Affected0.06220.5177-3-23.660.10
c.2113A>C
K705Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 K705Q missense variant (ClinVar ID 3699560.0) is listed as “Uncertain” in ClinVar and is present in gnomAD (variant ID 6‑33441372‑A‑C). Prediction tools that uniformly indicate a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus—derived from a majority vote of AlphaMissense‑Default (uncertain), ESM1b (benign), FATHMM (benign), and PROVEAN (benign)—also yields a benign classification; Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, predicts benign. Overall, the preponderance of evidence supports a benign impact for K705Q, and this conclusion does not contradict the ClinVar “Uncertain” status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.134866Structured0.379324Uncertain0.9220.3640.000Uncertain 16-33441372-A-C16.20e-7-5.787Likely Benign0.436AmbiguousLikely Benign-0.10Likely Benign0.00.33Likely Benign0.12Likely Benign-0.02Likely Benign0.142Likely Benign-0.24Neutral0.997Probably Damaging0.969Probably Damaging3.42Benign0.78Tolerated3.47100.30630.1014110.4-0.04
c.268G>C
V90L
2D
AIThe SynGAP1 missense variant V90L is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while SIFT uniquely predicts it as pathogenic. The consensus from the SGM framework, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a Likely Benign verdict. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports a benign outcome, the SGM Consensus also indicates Likely Benign, and Foldetta data are unavailable. With the majority of evidence pointing to a benign effect and no conflicting ClinVar annotation, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.570702Disordered0.542047Binding0.3430.8730.500-3.676Likely Benign0.522AmbiguousLikely Benign0.056Likely Benign-0.24Neutral0.103Benign0.015Benign4.02Benign0.00Affected0.13340.448721-0.414.03
c.268G>T
V90L
2D
AIThe SynGAP1 missense variant V90L is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus indicates Likely Benign, and Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign effect for V90L, and this conclusion does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.570702Disordered0.542047Binding0.3430.8730.500-3.676Likely Benign0.522AmbiguousLikely Benign0.056Likely Benign-0.24Neutral0.103Benign0.015Benign4.02Benign0.00Affected0.13340.448721-0.414.03
c.2710A>C
M904L
2D
AIThe SynGAP1 missense variant M904L is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.589073Binding0.3500.9200.250-1.839Likely Benign0.074Likely BenignLikely Benign0.050Likely Benign-0.24Neutral0.000Benign0.001Benign2.86Benign0.17Tolerated0.19150.4584421.9-18.03
c.2710A>T
M904L
2D
AIThe SynGAP1 missense variant M904L is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.589073Binding0.3500.9200.250-1.839Likely Benign0.074Likely BenignLikely Benign0.050Likely Benign-0.24Neutral0.000Benign0.001Benign2.86Benign0.17Tolerated0.19150.4584421.9-18.03
c.2908G>A
E970K
2D
AIThe SynGAP1 missense variant E970K is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign interpretation, and this conclusion does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.951925Disordered0.953422Binding0.3420.9020.750-3.344Likely Benign0.303Likely BenignLikely Benign0.102Likely Benign-0.24Neutral0.078Benign0.042Benign4.18Benign0.17Tolerated0.33720.736101-0.4-0.94
c.3083T>G
L1028R
2D
AIThe SynGAP1 missense variant L1028R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign (three benign votes versus one pathogenic). High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.899122Disordered0.995137Binding0.3640.7300.500-2.204Likely Benign0.793Likely PathogenicAmbiguous0.167Likely Benign-0.24Neutral0.960Probably Damaging0.761Possibly Damaging2.75Benign0.84Tolerated0.13280.1603-3-2-8.343.03
c.3092T>C
M1031T
2D
AIThe SynGAP1 missense variant M1031T is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443644‑T‑C). In silico prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). No tool predicts a pathogenic outcome; the only inconclusive result is AlphaMissense‑Default, which is treated as unavailable. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus is “Likely Benign,” and Foldetta data are not available. **Thus, the variant is most likely benign, and this conclusion does not contradict the ClinVar “Uncertain” status.**

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.865454Disordered0.995959Binding0.3400.7360.500Uncertain 16-33443644-T-C21.24e-6-1.863Likely Benign0.540AmbiguousLikely Benign0.085Likely Benign-0.24Neutral0.002Benign0.005Benign2.67Benign1.00Tolerated3.7750.15870.2264-1-1-2.6-30.09
c.3167G>T
G1056V
2D
AIThe SynGAP1 missense variant G1056V is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are ESM1b and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (2 benign vs 2 pathogenic), and Foldetta results are unavailable. Overall, the majority of evidence (7 benign vs 2 pathogenic) supports a benign classification. This consensus does not contradict ClinVar status, which has no entry for this variant. Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988291Disordered0.868632Binding0.4020.9350.875-8.130Likely Pathogenic0.097Likely BenignLikely Benign0.448Likely Benign-0.24Neutral0.292Benign0.110Benign1.83Pathogenic0.08Tolerated0.14880.3507-1-34.642.08
c.3169A>C
S1057R
2D
AIThe SynGAP1 missense variant S1057R is catalogued in gnomAD (ID 6‑33443721‑A‑C) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.8756-33443721-A-C-6.648Likely Benign0.379AmbiguousLikely Benign0.221Likely Benign-0.24Neutral0.677Possibly Damaging0.168Benign5.30Benign0.21Tolerated3.7750.15840.3620-10-3.769.11
c.3171C>A
S1057R
2D
AIThe SynGAP1 missense variant S1057R is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign. Only polyPhen‑2 HumDiv flags it as pathogenic, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.875-6.648Likely Benign0.379AmbiguousLikely Benign0.272Likely Benign-0.24Neutral0.677Possibly Damaging0.168Benign5.30Benign0.21Tolerated3.7750.15840.3620-10-3.769.11
c.3171C>G
S1057R
2D
AIThe SynGAP1 missense variant S1057R is catalogued in gnomAD (ID 6‑33443723‑C‑G) but has no ClinVar submission. Functional prediction tools largely converge on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all report benign or tolerated. Only polyPhen‑2 HumDiv flags it as pathogenic, while AlphaMissense‑Default remains uncertain. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus confirms a benign likelihood; Foldetta data are unavailable, so no stability evidence is provided. Taken together, the preponderance of evidence indicates the variant is most likely benign, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.8756-33443723-C-G-6.648Likely Benign0.379AmbiguousLikely Benign0.272Likely Benign-0.24Neutral0.677Possibly Damaging0.168Benign5.30Benign0.21Tolerated3.7750.15840.3620-10-3.769.11
c.3347G>C
G1116A
2D
AIThe SynGAP1 missense variant G1116A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.873279Binding0.3200.9090.750-5.753Likely Benign0.079Likely BenignLikely Benign0.288Likely Benign-0.24Neutral0.010Benign0.022Benign4.08Benign0.24Tolerated0.34170.4944102.214.03
c.3383G>A
G1128E
2D
AIThe SynGAP1 missense variant G1128E is present in gnomAD (6‑33443935‑G‑A) and has no ClinVar entry. In silico predictors that agree on a benign effect include REVEL, PROVEAN, PolyPhen‑2 HumDiv, PolyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. The SGM‑Consensus, which is a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also classifies the variant as likely benign. High‑accuracy tools reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus itself is a high‑accuracy majority vote. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its stability impact remains unknown. Overall, the computational evidence overwhelmingly supports a benign classification, and this is consistent with the absence of a pathogenic ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.896620Disordered0.865136Binding0.3090.9110.8756-33443935-G-A16.70e-7-5.580Likely Benign0.452AmbiguousLikely Benign0.235Likely Benign-0.24Neutral0.002Benign0.008Benign4.43Benign1.00Tolerated4.3240.16100.4497-20-3.172.06
c.3511G>T
A1171S
2D
AIThe SynGAP1 missense variant A1171S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the lack of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.599170Disordered0.702689Binding0.4720.7750.500-2.875Likely Benign0.077Likely BenignLikely Benign0.156Likely Benign-0.24Neutral0.009Benign0.012Benign5.54Benign0.08Tolerated0.25360.467611-2.616.00
c.3802C>G
L1268V
2D
AIThe SynGAP1 missense variant L1268V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv flags the variant as pathogenic, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports likely benign. Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for the variant, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.458154Structured0.804315Binding0.8590.6290.000-4.137Likely Benign0.109Likely BenignLikely Benign0.056Likely Benign-0.24Neutral0.649Possibly Damaging0.157Benign2.73Benign0.25Tolerated0.13310.2289210.4-14.03
c.484C>A
R162S
2D
AIThe SynGAP1 missense variant R162S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign (three benign votes versus one pathogenic). AlphaMissense‑Optimized is currently Uncertain, and no Foldetta stability result is available. Overall, the majority of high‑accuracy and consensus predictions indicate a benign impact. Thus, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.501700Disordered0.516348Binding0.3150.6920.250-1.395Likely Benign0.894Likely PathogenicAmbiguous0.191Likely Benign-0.24Neutral0.487Possibly Damaging0.272Benign4.14Benign0.75Tolerated0.30800.49740-13.7-69.11
c.19T>C
S7P
2D
AIThe SynGAP1 missense variant S7P is reported in gnomAD (ID 6‑33420283‑T‑C) but has no ClinVar entry. In silico prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign status. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority‑vote) is benign; Foldetta results are unavailable. Overall, the consensus of the majority of tools, including the high‑accuracy methods, points to a benign effect. This prediction is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.590140Disordered0.548467Binding0.3860.9220.7506-33420283-T-C-3.798Likely Benign0.111Likely BenignLikely Benign0.210Likely Benign-0.23Neutral0.267Benign0.029Benign4.07Benign0.00Affected4.3210.24740.4925-11-0.810.04
c.2122C>G
L708V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L708V is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the only inconclusive results are from FoldX (uncertain) and Foldetta (uncertain). High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also predicts benign, while Foldetta remains uncertain. Overall, the evidence strongly indicates that the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.250310Structured0.365875Uncertain0.9310.3780.000-4.361Likely Benign0.097Likely BenignLikely Benign1.59Ambiguous0.00.12Likely Benign0.86Ambiguous-0.02Likely Benign0.122Likely Benign-0.23Neutral0.158Benign0.035Benign3.35Benign0.94Tolerated0.10940.2460210.4-14.03
c.2383C>T
P795S
2D
AIThe SynGAP1 missense variant P795S is catalogued in gnomAD (6‑33442935‑C‑T) but has no entry in ClinVar. Across the spectrum of in‑silico predictors, every tool listed—REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—consistently scores the variant as benign. No pathogenic predictions are reported. Grouping by agreement, all available tools fall into the benign category, with no tools indicating pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates likely benign. Foldetta results are not provided, so they are treated as unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.972450Disordered0.410339Uncertain0.4570.9030.8756-33442935-C-T16.20e-7-5.846Likely Benign0.067Likely BenignLikely Benign0.056Likely Benign-0.23Neutral0.001Benign0.002Benign4.30Benign0.24Tolerated4.3220.35170.5766-110.8-10.04
c.2908G>C
E970Q
2D
AIThe SynGAP1 missense variant E970Q is catalogued in gnomAD (6-33443460‑G‑C) and has no ClinVar entry. All available in silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool reports a pathogenic outcome. Grouping by consensus, the benign‑predicting tools comprise the entire set, while no pathogenic predictions are present. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are unavailable. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.951925Disordered0.953422Binding0.3420.9020.7506-33443460-G-C16.20e-7-2.662Likely Benign0.141Likely BenignLikely Benign0.053Likely Benign-0.23Neutral0.007Benign0.006Benign4.13Benign0.21Tolerated4.3220.25770.6899220.0-0.98
c.3034C>T
P1012S
2D
AIThe SynGAP1 missense variant P1012S is catalogued in gnomAD (ID 6‑33443586‑C‑T) but has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are unavailable. Overall, the evidence strongly supports a benign classification, and this conclusion is consistent with the absence of a ClinVar pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.894674Binding0.3190.8660.6256-33443586-C-T21.24e-6-3.342Likely Benign0.087Likely BenignLikely Benign0.044Likely Benign-0.23Neutral0.224Benign0.131Benign2.81Benign0.22Tolerated3.7750.32170.5300-110.8-10.04
c.310C>A
R104S
2D
AIThe SynGAP1 missense variant R104S has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; no Foldetta stability result is available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.678998Binding0.3390.8690.625-2.790Likely Benign0.771Likely PathogenicLikely Benign0.143Likely Benign-0.23Neutral0.625Possibly Damaging0.118Benign4.13Benign0.00Affected0.24900.38060-13.7-69.11
c.3296A>C
Y1099S
2D
AIThe SynGAP1 missense variant Y1099S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this trend: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on current predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.885302Disordered0.974267Binding0.4000.8621.000-1.775Likely Benign0.139Likely BenignLikely Benign0.156Likely Benign-0.23Neutral0.149Benign0.026Benign2.90Benign0.62Tolerated0.45640.2298-3-20.5-76.10
c.3362G>C
S1121T
2D
AIThe SynGAP1 missense variant S1121T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is provided).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.894241Disordered0.810024Binding0.3650.9350.875-6.442Likely Benign0.069Likely BenignLikely Benign0.105Likely Benign-0.23Neutral0.011Benign0.026Benign5.45Benign0.00Affected0.21080.5582110.114.03
c.3928A>T
T1310S
2D
AIThe SynGAP1 missense variant T1310S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.959076Binding0.3980.9040.750-2.809Likely Benign0.078Likely BenignLikely Benign0.069Likely Benign-0.23Neutral0.089Benign0.120Benign2.80Benign0.17Tolerated0.26290.341811-0.1-14.03
c.43G>C
A15P
2D
AIThe SynGAP1 missense variant A15P is listed in ClinVar (ID 3688743.0) with an *Uncertain* clinical significance and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as *Likely Benign*. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which remains uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.436924Structured0.466055Uncertain0.3300.9120.375Uncertain 1-3.436Likely Benign0.097Likely BenignLikely Benign0.146Likely Benign-0.23Neutral0.880Possibly Damaging0.123Benign4.09Benign0.00Affected0.25730.69881-1-3.426.04
c.62T>A
F21Y
2D
AIThe SynGAP1 missense variant F21Y is listed in gnomAD (ID 6‑33420326‑T‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus also indicates a likely benign classification. No Foldetta (FoldX‑MD/Rosetta stability) result is available, so it does not influence the assessment. Overall, the preponderance of evidence points to a benign effect for F21Y, and this conclusion is not contradicted by any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.443284Uncertain0.3690.8970.5006-33420326-T-A-3.712Likely Benign0.352AmbiguousLikely Benign0.088Likely Benign-0.23Neutral0.273Benign0.153Benign4.15Benign0.00Affected4.3210.16980.260837-4.116.00
c.121C>A
R41S
2D
AIThe SynGAP1 missense variant R41S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for R41S, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.311707Structured0.431757Uncertain0.3440.7650.375-3.367Likely Benign0.393AmbiguousLikely Benign0.130Likely Benign-0.22Neutral0.686Possibly Damaging0.735Possibly Damaging4.24Benign0.00Affected0.31900.50130-13.7-69.11
c.178G>A
D60N
2D
AIThe SynGAP1 D60N missense variant has no ClinVar record and is not listed in gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.284882Structured0.480942Uncertain0.5210.6760.000-3.610Likely Benign0.577Likely PathogenicLikely Benign0.128Likely Benign-0.22Neutral0.805Possibly Damaging0.857Possibly Damaging4.13Benign0.00Affected0.12190.8168210.0-0.98
c.181G>A
E61K
2D
AIThe SynGAP1 E61K missense variant has no ClinVar entry and is not reported in gnomAD. Functional prediction tools cluster into two consensus groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the aggregate evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.352862Structured0.477329Uncertain0.5180.6990.125-4.953Likely Benign0.425AmbiguousLikely Benign0.120Likely Benign-0.22Neutral0.458Possibly Damaging0.678Possibly Damaging4.34Benign0.00Affected0.27360.569101-0.4-0.94
c.2230C>A
Q744K
2D
AIThe SynGAP1 missense variant Q744K is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Based on the collective predictions, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.540428Binding0.3160.8660.875-3.929Likely Benign0.099Likely BenignLikely Benign0.045Likely Benign-0.22Neutral0.001Benign0.002Benign2.79Benign0.07Tolerated0.17840.375711-0.40.04
c.2809G>A
D937N
2D
AIThe SynGAP1 missense variant D937N is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools largely support a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while only polyPhen‑2 HumDiv predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign outcome. High‑accuracy assessments further corroborate this view: AlphaMissense‑Optimized indicates benign, SGM‑Consensus is likely benign, and Foldetta results are unavailable. Taken together, the preponderance of evidence points to a benign impact for D937N, and this conclusion does not conflict with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.819762Disordered0.963385Binding0.3480.8830.625-4.259Likely Benign0.348AmbiguousLikely Benign0.095Likely Benign-0.22Neutral0.561Possibly Damaging0.139Benign2.72Benign0.81Tolerated0.24300.7825210.0-0.98
c.3161G>T
G1054V
2D
AIThe SynGAP1 missense variant G1054V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as likely benign. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts benign and the SGM‑Consensus also reports likely benign; Foldetta results are unavailable. Overall, the consensus of the available predictions points to a benign impact, and this is consistent with the lack of ClinVar evidence; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.878015Binding0.3890.9360.875-6.994Likely Benign0.110Likely BenignLikely Benign0.171Likely Benign-0.22Neutral0.818Possibly Damaging0.221Benign4.01Benign0.18Tolerated0.15780.3694-1-34.642.08
c.3202T>A
L1068M
2D
AIThe SynGAP1 missense variant L1068M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of predictions (six benign vs. four pathogenic) lean toward a benign impact. There is no ClinVar entry to contradict this assessment, so the variant is most likely benign based on current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.947281Disordered0.981041Binding0.3620.9070.875-5.739Likely Benign0.120Likely BenignLikely Benign0.043Likely Benign-0.22Neutral0.977Probably Damaging0.721Possibly Damaging2.49Pathogenic0.00Affected0.09300.458242-1.918.03
c.3539T>A
L1180H
2D
AIThe SynGAP1 missense variant L1180H is not reported in ClinVar and has no gnomAD allele, so its population frequency is unknown. Functional prediction tools show a split: benign calls come from REVEL, PROVEAN, ESM1b, and FATHMM, whereas pathogenic calls come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign outcome. High‑accuracy assessments highlight AlphaMissense‑Optimized as pathogenic, while the SGM‑Consensus leans benign; Foldetta results are not available. Overall, five of nine individual predictors favor pathogenicity, four favor benign, and the consensus tool suggests benign. Thus, the variant is most likely pathogenic based on the preponderance of high‑confidence predictions, and this assessment is not contradicted by ClinVar, which contains no entry for this change.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.626927Disordered0.559845Binding0.5910.6720.250-5.621Likely Benign0.976Likely PathogenicLikely Pathogenic0.213Likely Benign-0.22Neutral0.987Probably Damaging0.865Possibly Damaging2.65Benign0.00Affected0.09910.0860-2-3-7.023.98
c.3841G>T
A1281S
2D
AIThe SynGAP1 missense variant A1281S is reported in gnomAD (6‑33447889‑G‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv flags it as pathogenic, creating a single discordant call. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status, as none is currently assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.823549Disordered0.821556Binding0.4340.7210.8756-33447889-G-T-4.175Likely Benign0.080Likely BenignLikely Benign0.081Likely Benign-0.22Neutral0.649Possibly Damaging0.266Benign2.69Benign0.33Tolerated4.3240.28150.435611-2.616.00
c.3859C>A
P1287T
2D
AIThe SynGAP1 missense variant P1287T is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33447907‑C‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.827927Disordered0.813701Binding0.5380.7770.750Uncertain 16-33447907-C-A-3.940Likely Benign0.077Likely BenignLikely Benign0.044Likely Benign-0.22Neutral0.126Benign0.041Benign2.78Benign0.04Affected3.7750.11890.3995-100.93.99
c.62T>C
F21S
2D
AIThe SynGAP1 missense variant F21S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.443284Uncertain0.3690.8970.500-2.396Likely Benign0.745Likely PathogenicLikely Benign0.182Likely Benign-0.22Neutral0.462Possibly Damaging0.307Benign4.15Benign0.00Affected0.47930.1133-3-2-3.6-60.10
c.120T>A
D40E
2D
AIThe SynGAP1 missense variant D40E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic call comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign consensus. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion is consistent with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.384043Structured0.432002Uncertain0.3190.7690.375-3.520Likely Benign0.096Likely BenignLikely Benign0.050Likely Benign-0.21Neutral0.000Benign0.000Benign4.20Benign0.00Affected0.27640.8141320.014.03
c.120T>G
D40E
2D
AIThe SynGAP1 missense variant D40E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic call comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign consensus. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation. Thus, the variant is most likely benign, and this assessment does not contradict the ClinVar record, which contains no pathogenic claim.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.384043Structured0.432002Uncertain0.3190.7690.375-3.520Likely Benign0.096Likely BenignLikely Benign0.050Likely Benign-0.21Neutral0.000Benign0.000Benign4.20Benign0.00Affected0.27640.8141320.014.03
c.1585A>G
I529V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I529V is not reported in ClinVar (ClinVar status: not listed) but is present in gnomAD (gnomAD ID 6‑33438828‑A‑G). Prediction tools that uniformly indicate a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, the SGM Consensus is Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts Benign. Based on the collective predictions, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.318242Structured0.019545Uncertain0.9010.4030.0006-33438828-A-G16.20e-7-2.342Likely Benign0.068Likely BenignLikely Benign0.18Likely Benign0.00.03Likely Benign0.11Likely Benign0.36Likely Benign0.230Likely Benign-0.21Neutral0.019Benign0.014Benign-1.24Pathogenic1.00Tolerated3.37350.10430.352634-0.3-14.03
c.2380C>T
P794S
2D
AIThe SynGAP1 missense variant P794S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are not available, so they do not influence the assessment. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.979741Disordered0.408951Uncertain0.5500.8980.875-5.086Likely Benign0.079Likely BenignLikely Benign0.041Likely Benign-0.21Neutral0.025Benign0.010Benign4.29Benign0.13Tolerated0.36660.56041-10.8-10.04
c.2587C>A
L863M
2D
AIThe SynGAP1 missense variant L863M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). In contrast, the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic effect. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. Foldetta results are not available, so they do not influence the overall assessment. Based on the collective predictions, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.525368Disordered0.594839Binding0.2670.7950.250-5.137Likely Benign0.135Likely BenignLikely Benign0.111Likely Benign-0.21Neutral0.999Probably Damaging0.990Probably Damaging4.04Benign0.28Tolerated0.08110.392242-1.918.03
c.2689T>C
S897P
2D
AIThe SynGAP1 missense variant S897P is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized returns Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability prediction is available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.699094Disordered0.418474Uncertain0.2920.9280.500-4.088Likely Benign0.216Likely BenignLikely Benign0.097Likely Benign-0.21Neutral0.990Probably Damaging0.856Possibly Damaging2.64Benign0.04Affected0.20140.59331-1-0.810.04
c.2860C>G
P954A
2D
AIThe SynGAP1 missense variant P954A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. There is no ClinVar classification to contradict this conclusion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984159Disordered0.932268Binding0.4650.9260.750-4.985Likely Benign0.051Likely BenignLikely Benign0.072Likely Benign-0.21Neutral0.856Possibly Damaging0.652Possibly Damaging2.91Benign0.90Tolerated0.31030.55501-13.4-26.04
c.2887C>A
H963N
2D
AIThe SynGAP1 missense variant H963N is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical databases.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.983973Binding0.3250.8860.750-8.274Likely Pathogenic0.099Likely BenignLikely Benign0.089Likely Benign-0.21Neutral0.369Benign0.120Benign4.18Benign0.16Tolerated0.20940.359621-0.3-23.04
c.3399C>G
I1133M
2D
AIThe SynGAP1 missense variant I1133M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is benign, and this conclusion does not contradict any ClinVar annotation (none present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.832785Binding0.3160.8920.750-3.409Likely Benign0.096Likely BenignLikely Benign0.223Likely Benign-0.21Neutral0.016Benign0.009Benign5.45Benign0.06Tolerated0.07640.368521-2.618.03
c.3928A>G
T1310A
2D
AIThe SynGAP1 missense variant T1310A is not reported in ClinVar and is absent from gnomAD. All evaluated in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. The high‑accuracy consensus methods likewise support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.959076Binding0.3980.9040.750-2.883Likely Benign0.070Likely BenignLikely Benign0.084Likely Benign-0.21Neutral0.041Benign0.039Benign2.83Benign0.13Tolerated0.32380.3177102.5-30.03
c.55G>T
A19S
2D
AIThe SynGAP1 missense variant A19S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.529623Disordered0.443393Uncertain0.3780.9060.500-2.905Likely Benign0.107Likely BenignLikely Benign0.029Likely Benign-0.21Neutral0.225Benign0.027Benign4.17Benign0.00Affected0.32730.626011-2.616.00
c.65G>C
R22T
2D
AIThe SynGAP1 missense variant R22T is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools show a split: benign calls from REVEL, PROVEAN, polyPhen2_HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic calls come from polyPhen2_HumDiv and SIFT. The majority‑vote SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, indicates a likely benign effect. High‑accuracy predictors further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus itself is benign; Foldetta predictions are not available. Given the preponderance of benign predictions and the lack of pathogenic evidence, the variant is most likely benign. This assessment aligns with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.538167Disordered0.441505Uncertain0.3770.8910.500-4.079Likely Benign0.510AmbiguousLikely Benign0.146Likely Benign-0.21Neutral0.462Possibly Damaging0.227Benign4.23Benign0.00Affected0.21400.5599-1-13.8-55.08
c.82T>A
S28T
2D
AIThe SynGAP1 missense variant S28T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.545602Disordered0.438157Uncertain0.3540.8840.125-3.810Likely Benign0.081Likely BenignLikely Benign0.054Likely Benign-0.21Neutral0.000Benign0.000Benign4.20Benign0.64Tolerated0.18740.6140110.114.03
c.958G>A
V320I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V320I is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Prediction tools that uniformly indicate a benign effect include REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while Rosetta remains inconclusive. High‑accuracy assessments corroborate the benign trend: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta outputs, also predicts benign. Overall, the preponderance of evidence points to a benign effect for V320I, and this conclusion does not conflict with the current ClinVar designation of uncertainty.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.185198Structured0.419626Uncertain0.9050.2660.125Uncertain 1-5.220Likely Benign0.111Likely BenignLikely Benign-0.27Likely Benign0.20.66Ambiguous0.20Likely Benign0.01Likely Benign0.027Likely Benign-0.21Neutral0.198Benign0.114Benign1.77Pathogenic0.45Tolerated3.38230.05140.3207340.314.03
c.143T>A
F48Y
2D
AIThe SynGAP1 missense variant F48Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign. Foldetta results are unavailable. Overall, the majority of evidence indicates that F48Y is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.298791Structured0.440452Uncertain0.5580.7070.125-1.983Likely Benign0.124Likely BenignLikely Benign0.113Likely Benign-0.20Neutral0.000Benign0.001Benign4.26Benign0.00Affected0.16570.277873-4.116.00
c.2657C>T
A886V
2D
AIThe SynGAP1 missense variant A886V is listed in ClinVar with an “Uncertain” status and is present in the gnomAD database (gnomAD ID 6‑33443209‑C‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus call (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign, while Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.716283Disordered0.619166Binding0.3590.9220.500Uncertain 16-33443209-C-T181.12e-5-4.478Likely Benign0.078Likely BenignLikely Benign0.061Likely Benign-0.20Neutral0.888Possibly Damaging0.314Benign2.17Pathogenic0.00Affected4.3240.11310.5471002.428.05
c.2855G>C
G952A
2D
AIThe SynGAP1 missense variant G952A is predicted to be benign by every evaluated in‑silico tool. Benign predictions are reported by REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method, has no available result for this variant. ClinVar contains no entry for G952A, so there is no conflicting clinical annotation. Overall, the computational evidence indicates the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.910621Binding0.3410.9260.750-5.796Likely Benign0.075Likely BenignLikely Benign0.273Likely Benign-0.20Neutral0.000Benign0.000Benign3.26Benign0.08Tolerated0.33090.4957102.214.03
c.2998A>G
I1000V
2D
AIThe SynGAP1 missense variant I1000V is listed in ClinVar (ID 2572013.0) with an “Uncertain” clinical significance and is not reported in gnomAD. Functional prediction tools that assess evolutionary conservation and structural impact (REVEL, SIFT, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, PROVEAN, AlphaMissense‑Default) all converge on a benign outcome. No tool in the dataset predicts pathogenicity. High‑accuracy predictors reinforce this consensus: AlphaMissense‑Optimized reports a benign effect, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign classification. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict the ClinVar status, which remains uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.957020Binding0.2930.9040.625Uncertain 2-4.102Likely Benign0.098Likely BenignLikely Benign0.086Likely Benign-0.20Neutral0.437Benign0.170Benign2.76Benign0.81Tolerated4.3240.12200.340434-0.3-14.03
c.3001C>G
L1001V
2D
AIThe SynGAP1 missense variant L1001V is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized scores the variant as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the available predictions points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.958507Binding0.2690.9020.375-3.865Likely Benign0.075Likely BenignLikely Benign0.035Likely Benign-0.20Neutral0.022Benign0.008Benign2.71Benign0.00Affected0.15690.2714210.4-14.03
c.3052A>T
T1018S
2D
AIThe SynGAP1 missense variant T1018S is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently contains no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.959985Binding0.3480.8010.500-2.897Likely Benign0.074Likely BenignLikely Benign0.090Likely Benign-0.20Neutral0.004Benign0.008Benign2.48Pathogenic0.06Tolerated0.34260.340411-0.1-14.03
c.3053C>G
T1018S
2D
AIThe SynGAP1 missense variant T1018S is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently contains no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.959985Binding0.3480.8010.500-2.897Likely Benign0.074Likely BenignLikely Benign0.026Likely Benign-0.20Neutral0.004Benign0.008Benign2.48Pathogenic0.06Tolerated0.34260.340411-0.1-14.03
c.3116T>G
I1039S
2D
AIThe SynGAP1 missense variant I1039S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM all classify the substitution as benign. In contrast, SIFT and AlphaMissense‑Default predict a pathogenic impact. The high‑accuracy AlphaMissense‑Optimized score is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. No Foldetta stability assessment is available. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.979204Binding0.2920.8060.625-1.688Likely Benign0.829Likely PathogenicAmbiguous0.171Likely Benign-0.20Neutral0.032Benign0.008Benign2.76Benign0.03Affected0.29170.1294-1-2-5.3-26.08
c.3472G>A
V1158I
2D
AIThe SynGAP1 missense variant V1158I is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a 2‑vs‑2 split, and Foldetta results are unavailable. Overall, the balance of evidence leans toward a benign impact, and this conclusion does not contradict any ClinVar annotation because no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.599170Disordered0.877504Binding0.3690.8470.250-3.504Likely Benign0.597Likely PathogenicLikely Benign0.129Likely Benign-0.20Neutral0.992Probably Damaging0.989Probably Damaging2.49Pathogenic0.07Tolerated0.08630.4180430.314.03
c.3941C>T
P1314L
2D
AIThe SynGAP1 missense variant P1314L is listed in ClinVar as a benign alteration (ClinVar ID 646689.0) and is present in the gnomAD database (gnomAD ID 6‑33451815‑C‑T). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, which is consistent with the ClinVar classification. Thus, the variant is most likely benign and does not contradict the ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.971592Binding0.4670.9030.750Likely Benign 16-33451815-C-T21.24e-6-4.040Likely Benign0.118Likely BenignLikely Benign0.049Likely Benign-0.20Neutral0.421Benign0.066Benign4.19Benign0.05Affected3.7750.23100.5967-3-35.416.04
c.7A>G
R3G
2D
AIThe SynGAP1 missense variant R3G is reported in gnomAD (ID 6‑33420271‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it as pathogenic, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign; Foldetta results are unavailable. Taken together, the preponderance of evidence points to a benign impact. This conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.538167Disordered0.550331Binding0.3580.9200.8756-33420271-A-G-3.093Likely Benign0.160Likely BenignLikely Benign0.099Likely Benign-0.20Neutral0.115Benign0.018Benign3.99Benign0.00Affected4.3210.35590.4114-2-34.1-99.14
c.186T>A
D62E
2D
AIThe SynGAP1 missense variant D62E is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the consensus of the majority of tools and the high‑accuracy predictions point to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.425610Structured0.476010Uncertain0.5750.7200.125-2.653Likely Benign0.095Likely BenignLikely Benign0.065Likely Benign-0.19Neutral0.000Benign0.000Benign4.49Benign0.00Affected0.18840.5800320.014.03
c.186T>G
D62E
2D
AIThe SynGAP1 missense variant D62E is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic call comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the consensus of the majority of tools and the high‑accuracy predictions point to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.425610Structured0.476010Uncertain0.5750.7200.125-2.653Likely Benign0.095Likely BenignLikely Benign0.065Likely Benign-0.19Neutral0.000Benign0.000Benign4.49Benign0.00Affected0.18840.5800320.014.03
c.1909T>A
S637T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S637T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the only inconclusive result is from Rosetta, which is treated as unavailable. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts benign. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.076542Structured0.083482Uncertain0.9200.2530.000-4.116Likely Benign0.092Likely BenignLikely Benign0.36Likely Benign0.1-0.91Ambiguous-0.28Likely Benign-0.39Likely Benign0.067Likely Benign-0.19Neutral0.086Benign0.019Benign3.45Benign0.19Tolerated0.16750.4572110.114.03
c.2225G>A
R742Q
2D
AIThe SynGAP1 missense variant R742Q is listed in ClinVar (ID 928481.0) with an uncertain significance annotation and is observed in gnomAD (variant ID 6‑33441690‑G‑A). Consensus from multiple in‑silico predictors—REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—uniformly classify the change as benign. No tool in the dataset reports a pathogenic prediction. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. A protein‑folding stability analysis via Foldetta is not available for this variant. Overall, the computational evidence strongly favors a benign interpretation, which is consistent with the ClinVar uncertain status rather than contradicting it. The variant is most likely benign, and this assessment does not contradict its ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.871313Disordered0.509587Binding0.3090.8560.875Uncertain 26-33441690-G-A241.49e-5-4.090Likely Benign0.068Likely BenignLikely Benign0.054Likely Benign-0.19Neutral0.032Benign0.007Benign2.73Benign0.07Tolerated4.3220.36600.1530111.0-28.06
c.3083T>A
L1028Q
2D
AIThe SynGAP1 missense variant L1028Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation because no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.899122Disordered0.995137Binding0.3640.7300.500-2.718Likely Benign0.612Likely PathogenicLikely Benign0.179Likely Benign-0.19Neutral0.986Probably Damaging0.825Possibly Damaging2.80Benign0.38Tolerated0.11100.1403-2-2-7.314.97
c.3172G>T
G1058C
2D
AIThe SynGAP1 missense variant G1058C is reported in gnomAD (ID 6‑33443724‑G‑T) but has no ClinVar entry. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are polyPhen‑2 HumDiv, SIFT, and ESM1b. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of computational evidence points to a benign effect, and this is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.980739Disordered0.885724Binding0.4070.9290.8756-33443724-G-T16.21e-7-9.384Likely Pathogenic0.132Likely BenignLikely Benign0.264Likely Benign-0.19Neutral0.600Possibly Damaging0.433Benign5.19Benign0.01Affected3.7750.14560.4627-3-32.946.09
c.3238G>A
A1080T
2D
AIThe SynGAP1 missense variant A1080T (ClinVar ID 1473274.0) is listed as “Uncertain” in ClinVar and is present in gnomAD (ID 6‑33443790‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool in the dataset predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence strongly suggests the variant is most likely benign, which does not contradict the current ClinVar status of uncertainty.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.912647Disordered0.981457Binding0.3030.9000.750Conflicting 26-33443790-G-A171.06e-5-3.928Likely Benign0.133Likely BenignLikely Benign0.144Likely Benign-0.19Neutral0.253Benign0.042Benign4.10Benign0.60Tolerated3.7750.15640.710310-2.530.03
c.3522G>C
E1174D
2D
AIThe SynGAP1 missense variant E1174D is reported in gnomAD (variant ID 6-33444557-G-C) and has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No tool predicts pathogenicity. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is likely benign; Foldetta results are not available. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.483068Structured0.618958Binding0.5230.7340.3756-33444557-G-C16.20e-7-4.257Likely Benign0.253Likely BenignLikely Benign0.234Likely Benign-0.19Neutral0.002Benign0.006Benign5.45Benign0.36Tolerated4.3220.15570.4226230.0-14.03
c.3522G>T
E1174D
2D
AIThe SynGAP1 missense change E1174D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools that assess sequence conservation and structural impact (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized) all classify the variant as benign. No tool predicts pathogenicity. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a “Likely Benign” verdict, while AlphaMissense‑Optimized also reports benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, every available prediction supports a benign effect, and this conclusion is consistent with the lack of a ClinVar classification. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.483068Structured0.618958Binding0.5230.7340.375-4.257Likely Benign0.253Likely BenignLikely Benign0.234Likely Benign-0.19Neutral0.002Benign0.006Benign5.45Benign0.36Tolerated4.3220.15570.4226230.0-14.03
c.3865A>G
K1289E
2D
AIThe SynGAP1 missense variant K1289E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Based on the overall consensus of the majority of tools and the high‑accuracy predictions, the variant is most likely benign. This assessment does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.828700Binding0.5480.7870.625-3.088Likely Benign0.265Likely BenignLikely Benign0.138Likely Benign-0.19Neutral0.001Benign0.002Benign2.62Benign0.04Affected0.35590.0514010.40.94
c.3907G>A
G1303S
2D
AIThe SynGAP1 missense variant G1303S is listed in ClinVar (ID 1736068.0) with an “Uncertain” clinical significance and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Only polyPhen‑2 HumDiv predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; a Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this is consistent with the ClinVar “Uncertain” status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.871313Disordered0.886612Binding0.4290.8540.875Uncertain 1-2.271Likely Benign0.125Likely BenignLikely Benign0.155Likely Benign-0.19Neutral0.649Possibly Damaging0.433Benign2.84Benign0.18Tolerated0.26050.419710-0.430.03
c.53A>T
Y18F
2D
AIThe SynGAP1 missense variant Y18F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.483068Structured0.446314Uncertain0.3450.9080.375-2.371Likely Benign0.160Likely BenignLikely Benign0.059Likely Benign-0.19Neutral0.115Benign0.018Benign4.18Benign0.00Affected0.26750.3322734.1-16.00
c.2401G>C
G801R
2D
AIThe SynGAP1 missense variant G801R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The high‑accuracy AlphaMissense‑Optimized score is benign, and the SGM‑Consensus also indicates a benign outcome; Foldetta data are not available. Overall, the majority of evidence points to a benign effect, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.874069Disordered0.636323Binding0.3200.8920.625-4.226Likely Benign0.424AmbiguousLikely Benign0.045Likely Benign-0.18Neutral0.846Possibly Damaging0.624Possibly Damaging2.73Benign0.64Tolerated0.08500.3793-3-2-4.199.14
c.2572A>G
S858G
2D
AIThe SynGAP1 missense variant S858G is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumDiv, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only polyPhen‑2 HumVar indicates a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also predicts benign. The Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.482724Uncertain0.3050.8330.375-2.181Likely Benign0.068Likely BenignLikely Benign0.143Likely Benign-0.18Neutral0.259Benign0.786Possibly Damaging4.13Benign0.11Tolerated0.30840.5116100.4-30.03
c.2747T>C
V916A
2D
AIThe SynGAP1 missense variant V916A is not reported in ClinVar and is absent from gnomAD. Prediction tools that assess pathogenicity all converge on a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. No tool in the dataset indicates a pathogenic effect, so the pathogenic‑prediction group is empty. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign,” and the Foldetta stability analysis is not available. Based on the collective predictions, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.642678Disordered0.835395Binding0.3080.8790.250-2.524Likely Benign0.108Likely BenignLikely Benign0.116Likely Benign-0.18Neutral0.244Benign0.171Benign2.91Benign1.00Tolerated0.34550.284100-2.4-28.05
c.2833C>G
H945D
2D
AIThe SynGAP1 missense variant H945D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Pathogenic predictions come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for H945D, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.750-6.572Likely Benign0.191Likely BenignLikely Benign0.396Likely Benign-0.18Neutral0.982Probably Damaging0.870Possibly Damaging5.02Benign0.04Affected0.28030.22751-1-0.3-22.05
c.2854G>T
G952C
2D
AIThe SynGAP1 missense variant G952C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. Thus, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.910621Binding0.3410.9260.750-8.599Likely Pathogenic0.088Likely BenignLikely Benign0.272Likely Benign-0.18Neutral0.371Benign0.169Benign3.20Benign0.01Affected0.14580.4439-3-32.946.09
c.3170G>C
S1057T
2D
AIThe SynGAP1 missense variant S1057T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods indicates that the variant is most likely benign, and this assessment is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.875-6.375Likely Benign0.079Likely BenignLikely Benign0.241Likely Benign-0.18Neutral0.625Possibly Damaging0.170Benign5.26Benign0.60Tolerated0.22890.5976110.114.03
c.3293G>C
S1098T
2D
AIThe SynGAP1 missense variant S1098T is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.973030Binding0.3370.8551.000-4.144Likely Benign0.073Likely BenignLikely Benign0.051Likely Benign-0.18Neutral0.224Benign0.120Benign2.76Benign0.88Tolerated0.17060.6653110.114.03
c.3509G>A
S1170N
2D
AIThe SynGAP1 missense variant S1170N is reported in gnomAD (6‑33444544‑G‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. AlphaMissense‑Default is uncertain, and no Foldetta stability assessment is available. High‑accuracy predictions from AlphaMissense‑Optimized and the SGM‑Consensus both indicate a benign outcome, while the absence of a Foldetta result leaves that aspect unresolved. Overall, the majority of evidence points to a benign effect for S1170N, and this conclusion is not contradicted by any ClinVar classification (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.622677Disordered0.719138Binding0.4170.7670.5006-33444544-G-A16.20e-7-3.705Likely Benign0.413AmbiguousLikely Benign0.342Likely Benign-0.18Neutral0.992Probably Damaging0.925Probably Damaging5.39Benign0.86Tolerated4.3240.11320.423811-2.727.03
c.386C>T
S129L
2D
AIThe SynGAP1 missense variant S129L is catalogued in gnomAD (ID 6‑33432251‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) all report benign or likely benign. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors benign. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the preponderance of evidence indicates that S129L is most likely benign, and this assessment does not contradict any ClinVar status, as none is reported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.517562Disordered0.713635Binding0.3110.8800.6256-33432251-C-T16.20e-7-4.487Likely Benign0.456AmbiguousLikely Benign0.256Likely Benign-0.18Neutral0.000Benign0.000Benign4.14Benign0.05Affected3.7440.08850.5249-2-34.626.08
c.11C>T
S4F
2D
AIThe SynGAP1 missense variant S4F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for S4F, and this conclusion is consistent with the lack of any ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.608892Disordered0.547364Binding0.3900.9240.750-4.880Likely Benign0.317Likely BenignLikely Benign0.082Likely Benign-0.17Neutral0.676Possibly Damaging0.485Possibly Damaging4.13Benign0.00Affected0.06860.6270-3-23.660.10
c.161A>G
N54S
2D
AIThe SynGAP1 missense variant N54S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for the variant, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.196879Structured0.464669Uncertain0.5040.6590.000-5.358Likely Benign0.125Likely BenignLikely Benign0.121Likely Benign-0.17Neutral0.458Possibly Damaging0.678Possibly Damaging4.31Benign0.00Affected0.37400.7048112.7-27.03
c.2554G>A
G852S
2D
AIThe SynGAP1 missense variant G852S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.506063Binding0.2760.8160.625-4.786Likely Benign0.071Likely BenignLikely Benign0.091Likely Benign-0.17Neutral0.393Benign0.197Benign4.21Benign0.07Tolerated0.26960.512910-0.430.03
c.2698A>T
T900S
2D
AIThe SynGAP1 missense variant T900S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.465347Uncertain0.2890.9240.375-2.031Likely Benign0.098Likely BenignLikely Benign0.056Likely Benign-0.17Neutral0.224Benign0.171Benign2.70Benign0.71Tolerated0.33110.430111-0.1-14.03
c.2701G>C
A901P
2D
AIThe SynGAP1 missense variant A901P is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in silico predictors indicates a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy tools reinforce this view: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta stability analysis is not available. Overall, the majority of evidence supports a benign interpretation, and there is no conflict with ClinVar status, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.595080Disordered0.489838Uncertain0.3060.9170.375-4.035Likely Benign0.175Likely BenignLikely Benign0.124Likely Benign-0.17Neutral0.918Possibly Damaging0.500Possibly Damaging2.65Benign0.19Tolerated0.19300.59411-1-3.426.04
c.3001C>A
L1001I
2D
AIThe SynGAP1 missense variant L1001I is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. High‑accuracy consensus methods reinforce the benign assessment: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” No Foldetta stability prediction is available for this variant. Overall, the preponderance of evidence from both general and high‑accuracy tools points to a benign effect, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.958507Binding0.2690.9020.375-4.486Likely Benign0.076Likely BenignLikely Benign0.034Likely Benign-0.17Neutral0.022Benign0.018Benign2.69Benign0.00Affected0.09940.3264220.70.00
c.3112A>T
T1038S
2D
AIThe SynGAP1 missense variant T1038S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence supports a benign classification, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.982911Binding0.2790.7940.625-2.693Likely Benign0.198Likely BenignLikely Benign0.101Likely Benign-0.17Neutral0.649Possibly Damaging0.209Benign2.98Benign0.74Tolerated0.28790.403511-0.1-14.03
c.3113C>G
T1038S
2D
AIThe SynGAP1 missense variant T1038S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence supports a benign classification, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.982911Binding0.2790.7940.625-2.693Likely Benign0.198Likely BenignLikely Benign0.102Likely Benign-0.17Neutral0.649Possibly Damaging0.209Benign2.98Benign0.74Tolerated0.28790.403511-0.1-14.03
c.3176G>C
G1059A
2D
AIThe SynGAP1 missense variant G1059A is listed in ClinVar (ID 1420036.0) with an “Uncertain” clinical significance and is present in gnomAD (variant ID 6‑33443728‑G‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of computational evidence supports a benign impact for G1059A, which does not contradict the ClinVar “Uncertain” status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.898939Binding0.3990.9260.875Uncertain 16-33443728-G-C42.49e-6-6.754Likely Benign0.081Likely BenignLikely Benign0.329Likely Benign-0.17Neutral0.001Benign0.002Benign2.56Benign0.00Affected4.3220.32950.4944102.214.03
c.3181G>C
G1061R
2D
AIThe SynGAP1 missense variant G1061R is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while ESM1b and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because it contains two benign and two uncertain calls, and Foldetta results are unavailable. Overall, the balance of evidence favors a benign classification. This conclusion does not contradict ClinVar status, as the variant has not been reported there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.978672Disordered0.926729Binding0.3940.9230.875-7.721In-Between0.343AmbiguousLikely Benign0.315Likely Benign-0.17Neutral0.411Benign0.132Benign3.99Benign0.00Affected0.10370.4332-3-2-4.199.14
c.3956C>T
A1319V
2D
AIThe SynGAP1 missense variant A1319V is reported in gnomAD (ID 6‑33451830‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT predict pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority of the same four tools) is benign. Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for A1319V, and this conclusion is not contradicted by any ClinVar classification (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.842060Disordered0.960481Binding0.4540.8510.7506-33451830-C-T17.16e-7-5.015Likely Benign0.082Likely BenignLikely Benign0.167Likely Benign-0.17Neutral0.971Probably Damaging0.757Possibly Damaging4.14Benign0.02Affected3.7750.15830.6127002.428.05
c.3G>A
M1I
2D
AIThe SynGAP1 missense variant M1I is listed in ClinVar (ID 833646.0) with an uncertain significance annotation and is not reported in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM all classify the substitution as benign, while SIFT uniquely predicts it to be pathogenic. The consensus score from the SGM framework, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign outcome. High‑accuracy predictors are incomplete: AlphaMissense‑Optimized and the Foldetta stability assessment are unavailable for this variant. Taking the collective evidence into account, the variant is most likely benign, and this assessment does not conflict with the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.642678Disordered0.540766Binding0.3540.9240.875Conflicting 3-5.397Likely Benign0.227Likely Benign-0.17Neutral0.001Benign0.000Benign4.25Benign0.00Affected4.3210.16550.4008212.6-18.03
c.916G>A
V306I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V306I is not reported in ClinVar (no ClinVar ID) but is present in gnomAD (variant ID 6-33437821‑G‑A). Functional prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as likely benign, while Foldetta (combining FoldX‑MD and Rosetta outputs) yields an uncertain result. No prediction or stability assessment is missing; all available data are considered. Based on the preponderance of benign predictions and the lack of ClinVar evidence to the contrary, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.363090Structured0.315026Uncertain0.8960.2870.1256-33437821-G-A116.82e-6-5.989Likely Benign0.121Likely BenignLikely Benign1.13Ambiguous0.20.38Likely Benign0.76Ambiguous0.19Likely Benign0.154Likely Benign-0.17Neutral0.999Probably Damaging0.993Probably Damaging1.75Pathogenic0.36Tolerated3.38190.06030.3461340.314.03
c.108T>A
H36Q
2D
AIThe SynGAP1 missense variant H36Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.637480Disordered0.433974Uncertain0.3340.8340.375-3.642Likely Benign0.135Likely BenignLikely Benign0.044Likely Benign-0.16Neutral0.182Benign0.046Benign4.34Benign0.00Affected0.20420.457230-0.3-9.01
c.108T>G
H36Q
2D
AIThe SynGAP1 missense variant H36Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.637480Disordered0.433974Uncertain0.3340.8340.375-3.642Likely Benign0.135Likely BenignLikely Benign0.044Likely Benign-0.16Neutral0.182Benign0.046Benign4.34Benign0.00Affected0.20420.457230-0.3-9.01
c.13C>G
R5G
2D
AIThe SynGAP1 missense variant R5G is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Prediction tools that indicate a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.595080Disordered0.547847Binding0.3630.9200.750Uncertain 1-3.639Likely Benign0.150Likely BenignLikely Benign0.169Likely Benign-0.16Neutral0.013Benign0.003Benign4.12Benign0.00Affected4.3210.37600.4332-2-34.1-99.14
c.2008C>A
L670M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense change L670M occurs in the GAP domain. ClinVar contains no entry for this variant, but it is present in gnomAD (ID 6‑33441267‑C‑A). Prediction tools that classify the variant as benign include REVEL, FoldX, premPS, PROVEAN, SIFT, AlphaMissense‑Default, AlphaMissense‑Optimized, FATHMM, Foldetta, and the SGM‑Consensus score (Likely Benign). Tools that predict pathogenicity are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b; Rosetta gives an uncertain result. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as benign. Overall, the majority of evidence points to a benign effect, and this is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.161087Structured0.090855Uncertain0.8120.3850.0006-33441267-C-A21.24e-6-9.438Likely Pathogenic0.125Likely BenignLikely Benign-0.11Likely Benign0.00.70Ambiguous0.30Likely Benign0.06Likely Benign0.038Likely Benign-0.16Neutral0.970Probably Damaging0.777Possibly Damaging3.40Benign0.25Tolerated3.39270.08260.384924-1.918.03
c.2300T>A
I767N
2D
AIThe SynGAP1 missense variant I767N is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) predict a pathogenic outcome. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.321458Structured0.927771Binding0.3690.8720.125-5.117Likely Benign0.541AmbiguousLikely Benign0.122Likely Benign-0.16Neutral0.977Probably Damaging0.632Possibly Damaging4.04Benign0.06Tolerated0.10390.1012-2-3-8.00.94
c.26A>C
H9P
2D
AIThe SynGAP1 missense variant H9P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. The prediction is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.486429Structured0.528099Binding0.3940.9160.750-2.838Likely Benign0.061Likely BenignLikely Benign0.224Likely Benign-0.16Neutral0.107Benign0.006Benign4.19Benign0.00Affected0.26440.51690-21.6-40.02
c.3232G>A
V1078I
2D
AIThe SynGAP1 missense variant V1078I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic outcome, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as likely benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign. The Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the preponderance of evidence from multiple prediction algorithms and consensus methods suggests that V1078I is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.986989Binding0.2940.8980.750-3.652Likely Benign0.200Likely BenignLikely Benign0.120Likely Benign-0.16Neutral0.625Possibly Damaging0.266Benign3.98Benign0.07Tolerated0.07710.4693430.314.03
c.3232G>C
V1078L
2D
AIThe SynGAP1 missense variant V1078L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign classification. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is likely benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the collective evidence strongly suggests that V1078L is most likely benign, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.986989Binding0.2940.8980.750-2.547Likely Benign0.523AmbiguousLikely Benign0.091Likely Benign-0.16Neutral0.451Benign0.209Benign4.13Benign0.56Tolerated0.08890.534921-0.414.03
c.3517A>G
I1173V
2D
AIThe SynGAP1 missense variant I1173V is observed in gnomAD (ID 6‑33444552‑A‑G) and has no ClinVar entry. Consensus from multiple in‑silico predictors classifies the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report a benign effect, while no tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is Likely Benign, and Foldetta results are unavailable. Thus, based on current predictions, the variant is most likely benign and does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.501700Disordered0.653145Binding0.5210.7560.3756-33444552-A-G16.20e-7-3.564Likely Benign0.160Likely BenignLikely Benign0.143Likely Benign-0.16Neutral0.011Benign0.006Benign5.55Benign0.36Tolerated4.3240.10230.243934-0.3-14.03
c.35G>C
S12T
2D
AIThe SynGAP1 missense variant S12T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus, SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a benign effect. AlphaMissense‑Optimized independently scores the variant as benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.490599Uncertain0.3550.9160.500-4.304Likely Benign0.117Likely BenignLikely Benign0.075Likely Benign-0.16Neutral0.208Benign0.024Benign4.14Benign0.00Affected0.14870.6303110.114.03
c.3673T>G
S1225A
2D
AIThe SynGAP1 missense variant S1225A is not reported in ClinVar and is absent from gnomAD, indicating no known clinical annotation or population frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. The high‑accuracy consensus, SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly supports a benign classification, and this assessment does not contradict any ClinVar status, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.513880Disordered0.441915Uncertain0.8910.5440.500-3.157Likely Benign0.089Likely BenignLikely Benign0.257Likely Benign-0.16Neutral0.139Benign0.089Benign5.51Benign1.00Tolerated0.38040.3823112.6-16.00
c.38T>A
I13N
2D
AIThe SynGAP1 missense variant I13N is reported in gnomAD (ID 6‑33420302‑T‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) labels it “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign; Foldetta results are not available. Overall, the consensus of the majority of tools, including the high‑accuracy methods, indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.486429Structured0.482657Uncertain0.3180.9160.3756-33420302-T-A-3.725Likely Benign0.237Likely BenignLikely Benign0.096Likely Benign-0.16Neutral0.056Benign0.005Benign4.02Benign0.00Affected4.3210.12200.1100-3-2-8.00.94
c.1270G>A
V424I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V424I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, premPS, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as tolerated or benign. The only inconclusive results come from FoldX (uncertain) and Foldetta (uncertain). When high‑accuracy methods are considered separately, AlphaMissense‑Optimized predicts benign, the SGM Consensus—derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also predicts benign, while Foldetta remains uncertain. No tool predicts pathogenicity. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.050641Structured0.411431Uncertain0.9730.2480.000-3.814Likely Benign0.095Likely BenignLikely Benign-1.04Ambiguous0.1-0.48Likely Benign-0.76Ambiguous0.02Likely Benign0.084Likely Benign-0.15Neutral0.013Benign0.006Benign3.50Benign0.63Tolerated0.08740.2609430.314.03
c.2305C>A
L769I
2D
AIThe SynGAP1 missense variant L769I is listed in gnomAD (ID 6‑33442463‑C‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. No Foldetta stability result is available. Overall, the majority of evidence points to a benign impact, and this is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.411940Structured0.928432Binding0.3670.8830.2506-33442463-C-A-3.993Likely Benign0.110Likely BenignLikely Benign0.099Likely Benign-0.15Neutral0.836Possibly Damaging0.329Benign4.09Benign0.04Affected3.6460.08000.3108220.70.00
c.2387C>A
P796Q
2D
AIThe SynGAP1 missense variant P796Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign, while the only tool predicting a deleterious outcome is SIFT, which labels it pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) indicates likely benign; no Foldetta stability data are available. Overall, the consensus of the majority of predictors and the high‑accuracy tools points to a benign effect for P796Q, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation. Thus, the variant is most likely benign, and this assessment does not contradict any ClinVar classification, as no pathogenic claim is present.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.936162Disordered0.426363Uncertain0.4270.9000.875-6.575Likely Benign0.084Likely BenignLikely Benign0.074Likely Benign-0.15Neutral0.325Benign0.103Benign4.27Benign0.01Affected0.15620.41170-1-1.931.01
c.2389C>A
P797T
2D
AIThe SynGAP1 missense variant P797T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.926919Disordered0.449970Uncertain0.5610.9020.875-6.554Likely Benign0.064Likely BenignLikely Benign0.030Likely Benign-0.15Neutral0.901Possibly Damaging0.708Possibly Damaging4.23Benign0.24Tolerated0.17330.58300-10.93.99
c.268G>A
V90M
2D
AIThe SynGAP1 missense variant V90M is listed in gnomAD (6‑33425876‑G‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status, as none is reported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.570702Disordered0.542047Binding0.3430.8730.5006-33425876-G-A16.20e-7-5.017Likely Benign0.463AmbiguousLikely Benign0.053Likely Benign-0.15Neutral0.872Possibly Damaging0.162Benign3.98Benign0.00Affected4.3210.12210.439312-2.332.06
c.2697C>G
I899M
2D
AIThe SynGAP1 missense variant I899M is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of computational predictors and the high‑accuracy tools points to a benign impact for I899M. This conclusion is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.443727Uncertain0.2920.9280.375-3.407Likely Benign0.090Likely BenignLikely Benign0.067Likely Benign-0.15Neutral0.971Probably Damaging0.690Possibly Damaging2.70Benign0.01Affected0.06870.248921-2.618.03
c.3043A>C
T1015P
2D
AIThe SynGAP1 missense variant T1015P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence points to a benign impact for T1015P, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.928486Binding0.2950.8230.625-1.796Likely Benign0.077Likely BenignLikely Benign0.154Likely Benign-0.15Neutral0.586Possibly Damaging0.223Benign2.53Benign0.18Tolerated0.21760.45040-1-0.9-3.99
c.3215A>G
K1072R
2D
AIThe SynGAP1 missense variant K1072R is reported in gnomAD (ID 6‑33443767‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict it to be pathogenic. When predictions are grouped by consensus, the benign group contains seven tools, whereas the pathogenic group contains two. High‑accuracy assessments reinforce the benign view: AlphaMissense‑Optimized reports a benign outcome, and the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign effect. No Foldetta stability data are available, so folding‑stability evidence is unavailable. Overall, the majority of evidence points to a benign impact, and this is not in conflict with ClinVar status, which currently has no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.984675Binding0.3070.9070.7506-33443767-A-G16.23e-7-2.458Likely Benign0.100Likely BenignLikely Benign0.116Likely Benign-0.15Neutral0.997Probably Damaging0.989Probably Damaging4.16Benign0.88Tolerated3.7750.46550.206123-0.628.01
c.3274T>A
L1092M
2D
AIThe SynGAP1 missense variant L1092M is not reported in ClinVar and has no entries in gnomAD, indicating it has not been catalogued in these databases. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the substitution as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default tool remains uncertain, and no Foldetta stability assessment is available. High‑accuracy predictions from AlphaMissense‑Optimized and the SGM‑Consensus both support a benign outcome, whereas the absence of a Foldetta result precludes a stability‑based conclusion. Overall, the majority of evidence points to a benign effect for the variant, and this assessment does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.924947Disordered0.985431Binding0.3850.8901.000-5.348Likely Benign0.383AmbiguousLikely Benign0.083Likely Benign-0.15Neutral0.986Probably Damaging0.875Possibly Damaging2.66Benign0.21Tolerated0.09190.447942-1.918.03
c.48G>A
M16I
2D
AIThe SynGAP1 missense variant M16I is listed in ClinVar with an “Uncertain” status (ClinVar ID 1424213.0) and is present in gnomAD (6‑33420312‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this is consistent with the ClinVar “Uncertain” designation rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.440853Structured0.459925Uncertain0.3460.9080.375Uncertain 16-33420312-G-A16.49e-7-2.198Likely Benign0.722Likely PathogenicLikely Benign0.057Likely Benign-0.15Neutral0.000Benign0.000Benign4.28Benign0.00Affected4.3210.16060.3877212.6-18.03
c.48G>C
M16I
2D
AIThe SynGAP1 missense variant M16I is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational predictions and the high‑accuracy consensus suggest that M16I is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.440853Structured0.459925Uncertain0.3460.9080.375-2.198Likely Benign0.722Likely PathogenicLikely Benign0.057Likely Benign-0.15Neutral0.000Benign0.000Benign4.28Benign0.00Affected4.3210.16060.3877212.6-18.03
c.48G>T
M16I
2D
AIThe SynGAP1 missense variant M16I is not reported in ClinVar (ClinVar ID = None) but is present in gnomAD (ID = 6‑33420312‑G‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence points to a benign impact, and this is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.440853Structured0.459925Uncertain0.3460.9080.3756-33420312-G-T-2.198Likely Benign0.722Likely PathogenicLikely Benign0.057Likely Benign-0.15Neutral0.000Benign0.000Benign4.28Benign0.00Affected4.3210.16060.3877212.6-18.03
c.59C>G
P20R
2D
AIThe SynGAP1 missense variant P20R is listed in ClinVar (ID 566521.0) with an “Uncertain” status and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the current ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.529623Disordered0.442804Uncertain0.4480.8990.500Uncertain 1-3.548Likely Benign0.434AmbiguousLikely Benign0.146Likely Benign-0.15Neutral0.972Probably Damaging0.804Possibly Damaging4.33Benign0.00Affected4.3210.15090.32720-2-2.959.07
c.1027G>A
V343I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V343I is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33437932‑G‑A). Prediction tools that uniformly indicate a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, resolves to “Likely Benign” (3 benign vs. 1 pathogenic). High‑accuracy assessments are consistent: AlphaMissense‑Optimized is benign; the SGM‑Consensus is likely benign; and Foldetta, combining FoldX‑MD and Rosetta outputs, is benign. Overall, the collective evidence strongly supports a benign classification, and this does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.291804Structured0.383911Uncertain0.8820.4970.250Uncertain 26-33437932-G-A16.20e-7-6.020Likely Benign0.117Likely BenignLikely Benign-0.27Likely Benign0.0-0.04Likely Benign-0.16Likely Benign-0.39Likely Benign0.020Likely Benign-0.14Neutral0.159Benign0.084Benign1.98Pathogenic0.27Tolerated3.37250.10950.4536430.314.03240.2-26.9-0.20.2-0.20.2XPotentially BenignThe iso-propyl side chain of Val343, located in an anti-parallel β sheet strand (res. Gly341-Pro349), is packing against multiple hydrophobic residues of the C2 domain (e.g., Leu327, Leu274, Val365). In the variant simulations, the sec-butyl side chain of Ile343 is basically able to form the same interactions as valine due to its similar hydrophobic profile. The residue swap also does not seem to cause negative effects on the protein structure based on the simulations.
c.169C>G
L57V
2D
AIThe SynGAP1 missense variant L57V is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized returns Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability prediction is available. Overall, the majority of evidence points to a benign effect for the variant, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.254060Structured0.481044Uncertain0.5540.6420.000-3.598Likely Benign0.256Likely BenignLikely Benign0.051Likely Benign-0.14Neutral0.458Possibly Damaging0.745Possibly Damaging4.17Benign0.00Affected0.15330.4006210.4-14.03
c.2017C>A
L673I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L673I is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, premPS, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The remaining tools (FoldX, Rosetta, Foldetta, ESM1b) return uncertain or inconclusive results and are treated as unavailable evidence. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as likely benign, and Foldetta as uncertain. Taken together, the majority of reliable predictors indicate a benign effect, and there is no conflict with ClinVar status (which has no entry). Therefore, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.060549Structured0.104692Uncertain0.5450.3690.000-7.823In-Between0.099Likely BenignLikely Benign1.51Ambiguous0.21.89Ambiguous1.70Ambiguous-0.02Likely Benign0.036Likely Benign-0.14Neutral0.535Possibly Damaging0.112Benign3.37Benign0.47Tolerated0.09100.3689220.70.00
c.203T>A
L68Q
2D
AIThe SynGAP1 missense variant L68Q is listed in gnomAD (6‑33425811‑T‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions from REVEL, PROVEAN, ESM1b, and FATHMM; pathogenic predictions from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign outcome, reflecting the majority of benign calls. High‑accuracy assessments are limited: AlphaMissense‑Optimized is uncertain, and Foldetta results are not available. Based on the available evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.470567Uncertain0.4050.7680.2506-33425811-T-A53.10e-6-3.436Likely Benign0.826Likely PathogenicAmbiguous0.119Likely Benign-0.14Neutral0.943Possibly Damaging0.766Possibly Damaging4.15Benign0.00Affected4.3210.08640.0919-2-2-7.314.97
c.2188A>G
I730V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I730V is reported as “Likely Benign” in ClinVar and is not present in gnomAD. All available in‑silico predictors classify the change as benign: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also predicts benign. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.420109Uncertain0.5910.6190.750-3.960Likely Benign0.091Likely BenignLikely Benign0.25Likely Benign0.10.04Likely Benign0.15Likely Benign0.03Likely Benign0.028Likely Benign-0.14Neutral0.112Benign0.033Benign3.48Benign0.39Tolerated0.10100.230343-0.3-14.03
c.2389C>T
P797S
2D
AIThe SynGAP1 missense variant P797S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as tolerated or benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports it as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect for P797S, and this conclusion is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign, and this assessment does not contradict ClinVar.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.926919Disordered0.449970Uncertain0.5610.9020.875-6.232Likely Benign0.068Likely BenignLikely Benign0.029Likely Benign-0.14Neutral0.901Possibly Damaging0.637Possibly Damaging4.25Benign0.38Tolerated0.36340.52281-10.8-10.04
c.2441C>T
A814V
2D
AIThe SynGAP1 missense variant A814V is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority of high‑accuracy predictors (AlphaMissense‑Optimized and the SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also support a benign classification. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact, but these are the only tools in disagreement. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available, so these do not influence the overall inference. Overall, the preponderance of evidence points to a benign effect for A814V, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.411940Structured0.814830Binding0.3680.9020.250-4.147Likely Benign0.374AmbiguousLikely Benign0.119Likely Benign-0.14Neutral0.811Possibly Damaging0.489Possibly Damaging2.71Benign0.83Tolerated0.10880.6197002.428.05
c.25C>T
H9Y
2D
AIThe SynGAP1 missense variant H9Y is reported in gnomAD (ID 6‑33420289‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus itself is likely benign. Foldetta results are not available, so they do not influence the assessment. Overall, the preponderance of evidence points to the variant being most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.486429Structured0.528099Binding0.3940.9160.7506-33420289-C-T-3.833Likely Benign0.136Likely BenignLikely Benign0.082Likely Benign-0.14Neutral0.047Benign0.006Benign4.24Benign0.00Affected4.3210.12270.5024201.926.03
c.2639C>G
A880G
2D
AIThe SynGAP1 missense variant A880G is catalogued in gnomAD (ID 6‑33443191‑C‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all indicate a benign or likely benign outcome. Only SIFT classifies the change as pathogenic, representing a single discordant signal. High‑accuracy assessments confirm the benign prediction: AlphaMissense‑Optimized scores benign, and the SGM‑Consensus likewise reports likely benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the consensus of the majority of tools, including the high‑accuracy methods, points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.621441Binding0.3090.8740.2506-33443191-C-G21.24e-6-3.283Likely Benign0.071Likely BenignLikely Benign0.049Likely Benign-0.14Neutral0.002Benign0.007Benign2.62Benign0.04Affected3.7750.21360.384101-2.2-14.03
c.2769C>G
I923M
2D
AIThe SynGAP1 missense variant I923M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). In contrast, the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic effect. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is also likely benign. No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the majority of evidence indicates that I923M is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.562014Disordered0.964857Binding0.2920.8520.250-2.711Likely Benign0.195Likely BenignLikely Benign0.106Likely Benign-0.14Neutral0.973Probably Damaging0.721Possibly Damaging2.70Benign0.16Tolerated0.09490.387421-2.618.03
c.2845G>C
G949R
2D
AIThe SynGAP1 missense variant G949R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Consensus from standard in silico predictors shows a split: benign calls come from REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized, while pathogenic calls come from polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; ESM1b is uncertain. High‑accuracy assessment further supports a benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign outcome, and Foldetta data are unavailable. Overall, the preponderance of evidence indicates the variant is most likely benign, and this conclusion does not conflict with any ClinVar annotation because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988861Disordered0.874971Binding0.3650.9230.750-7.650In-Between0.301Likely BenignLikely Benign0.317Likely Benign-0.14Neutral0.997Probably Damaging0.934Probably Damaging2.21Pathogenic0.01Affected0.10950.4569-3-2-4.199.14
c.299A>C
Y100S
2D
AIThe SynGAP1 missense variant Y100S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.699094Disordered0.675421Binding0.3410.8800.625-1.217Likely Benign0.129Likely BenignLikely Benign0.182Likely Benign-0.14Neutral0.675Possibly Damaging0.175Benign4.31Benign0.00Affected0.50660.1600Weaken-3-20.5-76.10
c.3115A>C
I1039L
2D
AIThe SynGAP1 missense variant I1039L is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, is not available for this variant. Overall, the consensus of all available predictions strongly supports a benign classification, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.979204Binding0.2920.8060.625-2.035Likely Benign0.269Likely BenignLikely Benign0.083Likely Benign-0.14Neutral0.264Benign0.048Benign2.82Benign0.98Tolerated0.10570.460522-0.70.00
c.3143G>C
G1048A
2D
AISynGAP1 missense variant G1048A is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only polyPhen‑2 HumDiv predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” status. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that G1048A is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.923876Binding0.3460.9160.750-4.821Likely Benign0.079Likely BenignLikely Benign0.456Likely Benign-0.14Neutral0.573Possibly Damaging0.358Benign2.57Benign0.64Tolerated0.33010.5138102.214.03
c.3152G>C
G1051A
2D
AIThe SynGAP1 missense variant G1051A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence indicates a benign effect, and this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.900141Binding0.3580.9360.875-6.406Likely Benign0.081Likely BenignLikely Benign0.406Likely Benign-0.14Neutral0.009Benign0.004Benign-0.74Pathogenic1.00Tolerated0.33530.4944102.214.03
c.3155G>C
G1052A
2D
AIThe SynGAP1 missense variant G1052A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic outcome, creating a single discordant signal. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence supports a benign classification, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984420Disordered0.892068Binding0.3670.9380.875-6.945Likely Benign0.086Likely BenignLikely Benign0.382Likely Benign-0.14Neutral0.649Possibly Damaging0.287Benign3.93Benign1.00Tolerated0.32590.4949102.214.03
c.3310C>A
P1104T
2D
AIThe SynGAP1 missense variant P1104T is reported in gnomAD (variant ID 6‑33443862‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. No Foldetta stability analysis is available, so it does not influence the conclusion. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar classification (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.936162Disordered0.954801Binding0.4400.8630.8756-33443862-C-A-3.995Likely Benign0.070Likely BenignLikely Benign0.094Likely Benign-0.14Neutral0.770Possibly Damaging0.481Possibly Damaging2.76Benign0.09Tolerated3.7750.15490.6700-100.93.99
c.346T>G
Y116D
2D
AIThe SynGAP1 missense variant Y116D is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions strongly suggests that Y116D is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.661982Disordered0.670235Binding0.3810.8780.6250.542Likely Benign0.524AmbiguousLikely Benign0.302Likely Benign-0.14Neutral0.000Benign0.001Benign4.24Benign0.83Tolerated0.46030.0545-4-3-2.2-48.09
c.3502A>G
I1168V
2D
AIThe SynGAP1 missense variant I1168V is listed in ClinVar (ID 936001.0) with an “Uncertain” status and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports a “Likely Benign” outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this consensus does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.642678Disordered0.763262Binding0.4230.7960.500Uncertain 1-3.263Likely Benign0.524AmbiguousLikely Benign0.363Likely Benign-0.14Neutral0.876Possibly Damaging0.643Possibly Damaging5.47Benign0.84Tolerated3.8830.13390.437443-0.3-14.03
c.3874C>G
L1292V
2D
AIThe SynGAP1 missense variant L1292V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is benign, and this conclusion does not contradict any ClinVar annotation (none present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.779859Disordered0.882643Binding0.5860.8000.625-4.943Likely Benign0.121Likely BenignLikely Benign0.049Likely Benign-0.14Neutral0.058Benign0.038Benign2.67Benign0.07Tolerated0.17690.2605210.4-14.03
c.3973C>A
P1325T
2D
AIThe SynGAP1 missense variant P1325T is reported in gnomAD (ID 6‑33451847‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign effect for P1325T, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.893621Binding0.4390.7910.8756-33451847-C-A-5.880Likely Benign0.083Likely BenignLikely Benign0.135Likely Benign-0.14Neutral0.000Benign0.001Benign4.07Benign0.00Affected4.3210.18140.5150-100.93.99
c.502C>A
H168N
2D
AIThe SynGAP1 missense variant H168N is not reported in ClinVar and is absent from gnomAD. All evaluated in‑silico predictors classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. No tools predict pathogenicity. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.433034Structured0.502450Binding0.4020.6780.125-4.764Likely Benign0.089Likely BenignLikely Benign0.081Likely Benign-0.14Neutral0.016Benign0.015Benign4.29Benign0.60Tolerated0.15160.258921-0.3-23.04
c.16G>A
A6T
2D
AIThe SynGAP1 missense variant A6T is reported in gnomAD (variant ID 6-33420280‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus also reports likely benign; Foldetta results are not available. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods points to a benign impact. This conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.566480Disordered0.549054Binding0.3770.9200.8756-33420280-G-A-3.711Likely Benign0.130Likely BenignLikely Benign0.089Likely Benign-0.13Neutral0.027Benign0.004Benign4.11Benign0.00Affected4.3210.15210.683601-2.530.03
c.1953G>C
E651D
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant E651D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: SGM‑Consensus, REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen2_HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen2_HumDiv predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores the variant as benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign effect; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also reports a benign prediction. No prediction tool or stability analysis is inconclusive. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.088832Structured0.365409Uncertain0.9550.3400.000-3.220Likely Benign0.231Likely BenignLikely Benign0.16Likely Benign0.10.33Likely Benign0.25Likely Benign-0.29Likely Benign0.153Likely Benign-0.13Neutral0.906Possibly Damaging0.429Benign3.48Benign0.53Tolerated0.18130.3762320.0-14.03
c.1953G>T
E651D
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant E651D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: SGM‑Consensus, REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen2_HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only polyPhen2_HumDiv predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores the variant as benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign effect; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also reports a benign prediction. No prediction tool or stability analysis is inconclusive or missing. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.088832Structured0.365409Uncertain0.9550.3400.000-3.220Likely Benign0.231Likely BenignLikely Benign0.16Likely Benign0.10.33Likely Benign0.25Likely Benign-0.29Likely Benign0.153Likely Benign-0.13Neutral0.906Possibly Damaging0.429Benign3.48Benign0.53Tolerated0.18130.3762320.0-14.03
c.202C>A
L68M
2D
AIThe SynGAP1 missense variant L68M is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in‑silico predictors shows a split: benign calls come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic calls arise from polyPhen‑2 (HumDiv and HumVar) and SIFT. The AlphaMissense‑Default tool remains uncertain. High‑accuracy assessments reinforce the benign trend: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports Likely Benign, and no Foldetta stability data are available. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the lack of ClinVar annotation and gnomAD presence, so there is no contradiction with existing clinical databases.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.470567Uncertain0.4050.7680.250-5.580Likely Benign0.442AmbiguousLikely Benign0.094Likely Benign-0.13Neutral0.824Possibly Damaging0.665Possibly Damaging4.09Benign0.00Affected0.05650.276242-1.918.03
c.215G>A
R72Q
2D
AIThe SynGAP1 missense variant R72Q is reported in gnomAD (variant ID 6-33425823‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. In contrast, polyPhen‑2 HumDiv and SIFT predict a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for R72Q, and this conclusion is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.497853Structured0.455349Uncertain0.3550.8190.3756-33425823-G-A-4.413Likely Benign0.135Likely BenignLikely Benign0.100Likely Benign-0.13Neutral0.829Possibly Damaging0.238Benign4.20Benign0.00Affected4.3210.35700.2380111.0-28.06
c.2458T>C
Y820H
2D
AIThe SynGAP1 missense variant Y820H is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33443010‑T‑C). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, and FATHMM, while those that agree on a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. Uncertain predictions come from ESM1b and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) leaning toward benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict ClinVar status, as the variant is not yet classified in that database.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.733139Disordered0.695550Binding0.2930.8830.6256-33443010-T-C53.10e-6-7.432In-Between0.928Likely PathogenicAmbiguous0.129Likely Benign-0.13Neutral0.999Probably Damaging0.989Probably Damaging2.70Benign0.24Tolerated3.7750.24980.070420-1.9-26.03
c.2849G>C
G950A
2D
AIThe SynGAP1 missense variant G950A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only FATHMM predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict, reflecting the majority of benign calls. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.888649Binding0.3680.9230.750-6.557Likely Benign0.081Likely BenignLikely Benign0.339Likely Benign-0.13Neutral0.059Benign0.061Benign2.28Pathogenic0.08Tolerated0.33430.4957102.214.03
c.2977C>T
P993S
2D
AIThe SynGAP1 missense variant P993S is reported in gnomAD (ID 6‑33443529‑C‑T) and has no ClinVar entry. All evaluated in silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are unavailable. Based on the unanimous benign predictions and lack of ClinVar pathogenicity, the variant is most likely benign and does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.923979Binding0.3190.9080.7506-33443529-C-T31.86e-6-3.665Likely Benign0.068Likely BenignLikely Benign0.054Likely Benign-0.13Neutral0.011Benign0.023Benign4.26Benign0.59Tolerated4.3220.34210.5465-110.8-10.04
c.3451T>G
S1151A
2D
AIThe SynGAP1 missense variant S1151A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.741537Disordered0.805072Binding0.3940.8390.625-3.311Likely Benign0.077Likely BenignLikely Benign0.084Likely Benign-0.13Neutral0.889Possibly Damaging0.535Possibly Damaging2.75Benign0.42Tolerated0.47110.5087112.6-16.00
c.892C>A
P298T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant P298T is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are polyPhen‑2 (HumDiv and HumVar) and FATHMM. The remaining tools—FoldX, Rosetta, Foldetta, and ESM1b—return uncertain results and are treated as unavailable for pathogenicity inference. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction, while Foldetta remains uncertain. Overall, the preponderance of evidence points to a benign effect for P298T, and this conclusion does not contradict any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.328603Structured0.268765Uncertain0.8600.2830.500-7.366In-Between0.104Likely BenignLikely Benign1.44Ambiguous0.21.03Ambiguous1.24Ambiguous0.04Likely Benign0.209Likely Benign-0.13Neutral0.939Possibly Damaging0.739Possibly Damaging1.96Pathogenic1.00Tolerated0.15950.63490-10.93.99
c.97C>G
Q33E
2D
AIThe SynGAP1 missense variant Q33E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign status: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.436712Uncertain0.3420.8600.3750.191Likely Benign0.110Likely BenignLikely Benign0.024Likely Benign-0.13Neutral0.017Benign0.014Benign4.25Benign0.00Affected0.17730.3326220.00.98
c.1159G>A
G387S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 G387S missense variant is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (variant ID 6‑33438064‑G‑A). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are FoldX and FATHMM; Rosetta is uncertain. The high‑accuracy consensus (SGM‑Consensus) is derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN and is therefore likely benign. AlphaMissense‑Optimized itself predicts benign. Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, predicts a pathogenic effect. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar classification (none available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.642678Disordered0.422910Uncertain0.2930.8610.7506-33438064-G-A-4.674Likely Benign0.089Likely BenignLikely Benign2.37Destabilizing0.51.94Ambiguous2.16Destabilizing0.12Likely Benign0.359Likely Benign-0.12Neutral0.000Benign0.002Benign1.33Pathogenic0.13Tolerated4.3230.30510.472401-0.430.03
c.16G>C
A6P
2D
AIThe SynGAP1 missense variant A6P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.566480Disordered0.549054Binding0.3770.9200.875-3.440Likely Benign0.090Likely BenignLikely Benign0.148Likely Benign-0.12Neutral0.000Benign0.000Benign4.06Benign0.00Affected0.20930.50071-1-3.426.04
c.1758C>A
D586E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 D586E missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Optimized, and Foldetta. Those that predict a pathogenic outcome are polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Default; Rosetta is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a 2‑vs‑2 split. Overall, the majority of evidence points to a benign effect. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.060549Structured0.066018Uncertain0.8660.2410.000-3.233Likely Benign0.683Likely PathogenicLikely Benign-0.42Likely Benign0.10.88Ambiguous0.23Likely Benign0.38Likely Benign0.367Likely Benign-0.12Neutral0.929Possibly Damaging0.969Probably Damaging-1.20Pathogenic1.00Tolerated0.13040.5126320.014.03
c.1758C>G
D586E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 D586E missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Default; Rosetta is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a 2‑to‑2 split. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.060549Structured0.066018Uncertain0.8660.2410.000-3.233Likely Benign0.683Likely PathogenicLikely Benign-0.42Likely Benign0.10.88Ambiguous0.23Likely Benign0.38Likely Benign0.367Likely Benign-0.12Neutral0.929Possibly Damaging0.969Probably Damaging-1.20Pathogenic1.00Tolerated0.13040.5126320.014.03
c.2207G>A
R736H
2D
AIThe SynGAP1 missense variant R736H is listed in ClinVar (ID 1351080.0) with an “Uncertain” status and is present in gnomAD (variant ID 6‑33441672‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign. Foldetta results are not available. Overall, the majority of computational evidence indicates a benign impact, and this does not contradict the ClinVar “Uncertain” classification. Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.415259Uncertain0.3050.7710.875Uncertain 16-33441672-G-A63.72e-6-5.409Likely Benign0.067Likely BenignLikely Benign0.029Likely Benign-0.12Neutral0.004Benign0.001Benign2.50Benign0.00Affected4.0730.28460.0921201.3-19.05
c.2242C>A
L748M
2D
AIThe SynGAP1 missense variant L748M is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for the variant, and this is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.611637Binding0.3390.8630.750-3.935Likely Benign0.089Likely BenignLikely Benign0.060Likely Benign-0.12Neutral0.991Probably Damaging0.852Possibly Damaging2.70Benign0.05Affected0.09090.386342-1.918.03
c.2590G>C
A864P
2D
AIThe SynGAP1 missense variant A864P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only polyPhen‑2 HumDiv indicates a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as likely benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign and the SGM‑Consensus also reports likely benign; Foldetta results are unavailable. Overall, the consensus of the available predictions points to a benign effect, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.549308Disordered0.611966Binding0.2690.7880.250-3.665Likely Benign0.093Likely BenignLikely Benign0.067Likely Benign-0.12Neutral0.586Possibly Damaging0.211Benign2.60Benign0.09Tolerated0.19410.57461-1-3.426.04
c.3155G>T
G1052V
2D
AIThe SynGAP1 missense variant G1052V is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate benign, while the high‑accuracy AlphaMissense‑Optimized score is benign and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign. In contrast, polyPhen‑2 HumDiv and HumVar both predict pathogenic, and ESM1b remains uncertain. No Foldetta stability assessment is available, so it does not influence the overall interpretation. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984420Disordered0.892068Binding0.3670.9380.875-7.717In-Between0.094Likely BenignLikely Benign0.452Likely Benign-0.12Neutral0.901Possibly Damaging0.619Possibly Damaging3.90Benign0.19Tolerated0.13290.3499-1-34.642.08
c.3173G>T
G1058V
2D
AIThe SynGAP1 missense variant G1058V is reported in gnomAD (variant ID 6‑33443725‑G‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.980739Disordered0.885724Binding0.4070.9290.8756-33443725-G-T16.21e-7-6.877Likely Benign0.114Likely BenignLikely Benign0.152Likely Benign-0.12Neutral0.000Benign0.001Benign5.22Benign0.01Affected3.7750.15610.3694-3-14.642.08
c.3222G>C
Q1074H
2D
AIThe SynGAP1 missense variant Q1074H is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools uniformly favor a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity, and the only uncertain call comes from AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports the variant as “Likely Benign.” High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.987006Binding0.3390.8970.750-5.051Likely Benign0.381AmbiguousLikely Benign0.053Likely Benign-0.12Neutral0.006Benign0.008Benign2.67Benign0.07Tolerated0.14360.4407300.39.01
c.3222G>T
Q1074H
2D
AIThe SynGAP1 missense variant Q1074H is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools uniformly favor a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity, and the only uncertain call comes from AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports the variant as “Likely Benign.” High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.987006Binding0.3390.8970.750-5.051Likely Benign0.381AmbiguousLikely Benign0.053Likely Benign-0.12Neutral0.006Benign0.008Benign2.67Benign0.07Tolerated0.14360.4407300.39.01
c.3362G>A
S1121N
2D
AIThe SynGAP1 missense variant S1121N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and SIFT—suggest a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable. Overall, the consensus of the majority of predictors and the high‑accuracy tools points to a benign classification, with no conflict with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.894241Disordered0.810024Binding0.3650.9350.875-6.564Likely Benign0.105Likely BenignLikely Benign0.221Likely Benign-0.12Neutral0.802Possibly Damaging0.266Benign5.50Benign0.00Affected0.19800.421111-2.727.03
c.65G>A
R22K
2D
AIThe SynGAP1 missense variant R22K is reported in gnomAD (variant ID 6‑33420329‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign effect for R22K, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.538167Disordered0.441505Uncertain0.3770.8910.5006-33420329-G-A-4.736Likely Benign0.268Likely BenignLikely Benign0.032Likely Benign-0.12Neutral0.140Benign0.067Benign4.27Benign0.00Affected4.3210.64130.5384Strenghten230.6-28.01
c.1022G>A
G341D
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant G341D is not reported in ClinVar (ClinVar ID: None) but is present in gnomAD (ID: 6-33437927‑G‑A). Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, SIFT, and polyPhen‑2 HumVar. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, FATHMM, and AlphaMissense‑Default. The remaining tools—Foldetta, AlphaMissense‑Optimized, ESM1b, and Rosetta—return uncertain or inconclusive results and are treated as unavailable for pathogenicity inference. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Considering the majority of standard tools lean benign but the high‑accuracy consensus indicates pathogenicity, the variant is most likely pathogenic based on current predictions, and this assessment does not contradict ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.356642Structured0.431164Uncertain0.7450.4790.2506-33437927-G-A63.72e-6-7.402In-Between0.871Likely PathogenicAmbiguous0.28Likely Benign0.1-1.32Ambiguous-0.52Ambiguous-0.04Likely Benign0.295Likely Benign-0.11Neutral0.454Possibly Damaging0.192Benign0.34Pathogenic0.25Tolerated3.42130.17270.2241-11-3.158.04
c.172A>C
M58L
2D
AIThe SynGAP1 missense variant M58L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as tolerated or benign. Only SIFT predicts a deleterious impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized scores benign, and the SGM‑Consensus result is benign; Foldetta data are not available. Consequently, the aggregate evidence points to a benign effect for M58L, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.188120Structured0.484415Uncertain0.5150.6650.000-0.661Likely Benign0.240Likely BenignLikely Benign0.208Likely Benign-0.11Neutral0.006Benign0.039Benign4.77Benign0.00Affected0.15140.4621421.9-18.03
c.172A>T
M58L
2D
AIThe SynGAP1 missense variant M58L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar annotation—there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.188120Structured0.484415Uncertain0.5150.6650.000-0.661Likely Benign0.240Likely BenignLikely Benign0.208Likely Benign-0.11Neutral0.006Benign0.039Benign4.77Benign0.00Affected0.15140.4621421.9-18.03
c.25C>G
H9D
2D
AIThe SynGAP1 missense variant H9D has no ClinVar entry and is not reported in gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign, while only SIFT predicts it to be pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, the SGM‑Consensus (majority of the high‑accuracy tools) is benign, and the Foldetta stability analysis is unavailable. Overall, the consensus of available predictions indicates that the variant is most likely benign, with no conflict with ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.486429Structured0.528099Binding0.3940.9160.750-2.912Likely Benign0.168Likely BenignLikely Benign0.217Likely Benign-0.11Neutral0.024Benign0.002Benign4.24Benign0.00Affected0.28230.28931-1-0.3-22.05
c.2639C>T
A880V
2D
AIThe SynGAP1 missense variant A880V is reported in gnomAD (variant ID 6‑33443191‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv flags the change as pathogenic, creating a single discordant prediction. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the preponderance of evidence points to a benign impact for A880V, and this conclusion is not contradicted by any ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.621441Binding0.3090.8740.2506-33443191-C-T16.20e-7-5.440Likely Benign0.121Likely BenignLikely Benign0.095Likely Benign-0.11Neutral0.761Possibly Damaging0.399Benign2.58Benign1.00Tolerated3.7750.09470.5362002.428.05
c.3133G>T
A1045S
2D
AIThe SynGAP1 missense variant A1045S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975609Disordered0.948874Binding0.3520.8820.750-3.724Likely Benign0.073Likely BenignLikely Benign0.055Likely Benign-0.11Neutral0.011Benign0.010Benign2.66Benign0.46Tolerated0.26480.549311-2.616.00
c.542A>G
H181R
2D
AIThe SynGAP1 missense variant H181R is not reported in ClinVar (ClinVar ID None) and has no entries in gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus likewise indicates Likely Benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.505461Disordered0.439530Uncertain0.2940.6160.500-3.668Likely Benign0.521AmbiguousLikely Benign0.174Likely Benign-0.11Neutral0.818Possibly Damaging0.188Benign4.35Benign1.00Tolerated0.15850.178220-1.319.05
c.613A>G
I205V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I205V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools uniformly indicate a benign effect: REVEL, FoldX, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all classify the variant as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, the SGM Consensus predicts likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) also predicts benign. Based on the consensus of all available predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.264545Structured0.409933Uncertain0.8210.4140.125-2.232Likely Benign0.063Likely BenignLikely Benign0.45Likely Benign0.0-0.18Likely Benign0.14Likely Benign0.11Likely Benign0.113Likely Benign-0.11Neutral0.001Benign0.007Benign4.20Benign0.84Tolerated0.08970.279143-0.3-14.03
c.19T>G
S7A
2D
AIThe SynGAP1 missense variant S7A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus, SGM‑Consensus, is derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, all of which are benign, so the consensus is benign. AlphaMissense‑Optimized also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the available predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.590140Disordered0.548467Binding0.3860.9220.750-3.613Likely Benign0.072Likely BenignLikely Benign0.137Likely Benign-0.10Neutral0.002Benign0.001Benign4.18Benign0.00Affected0.54850.4355Weaken112.6-16.00
c.23T>C
I8T
2D
AIThe SynGAP1 missense variant I8T is reported in gnomAD (variant ID 6‑33420287‑T‑C) but has no ClinVar entry. In silico prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.490133Structured0.543080Binding0.3410.9160.6256-33420287-T-C-3.149Likely Benign0.239Likely BenignLikely Benign0.108Likely Benign-0.10Neutral0.047Benign0.006Benign4.03Benign0.00Affected4.3210.09490.1019-10-5.2-12.05
c.2629C>G
L877V
2D
AIThe SynGAP1 missense variant L877V is not reported in ClinVar and is absent from gnomAD. All evaluated in‑silico predictors classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence strongly supports a benign classification, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.653063Disordered0.634010Binding0.2650.8750.250-5.063Likely Benign0.097Likely BenignLikely Benign0.022Likely Benign-0.10Neutral0.232Benign0.109Benign2.71Benign0.26Tolerated0.17260.3178210.4-14.03
c.2875C>A
H959N
2D
AIThe SynGAP1 missense variant H959N is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only ESM1b predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from multiple independent predictors and high‑accuracy tools indicates that H959N is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.980566Binding0.3330.9050.750-8.811Likely Pathogenic0.104Likely BenignLikely Benign0.115Likely Benign-0.10Neutral0.144Benign0.058Benign4.15Benign0.21Tolerated0.22980.383821-0.3-23.04
c.2906G>A
G969E
2D
AIThe SynGAP1 missense variant G969E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.956572Binding0.4050.8980.750-4.721Likely Benign0.167Likely BenignLikely Benign0.118Likely Benign-0.10Neutral0.611Possibly Damaging0.171Benign4.28Benign0.01Affected0.16630.53990-2-3.172.06
c.308G>A
G103D
2D
AIThe SynGAP1 missense variant G103D is not reported in ClinVar and has no entry in gnomAD. Consensus from multiple in‑silico predictors shows a predominance of benign calls: REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict a benign effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT each predict a pathogenic impact. The AlphaMissense‑Default tool remains uncertain, and no Foldetta stability assessment is available. High‑accuracy tools specifically highlight benign predictions: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and Foldetta data are missing. Overall, the balance of evidence points to a benign effect for G103D, and this assessment does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.687376Binding0.3810.8770.625-3.523Likely Benign0.477AmbiguousLikely Benign0.110Likely Benign-0.10Neutral0.949Possibly Damaging0.617Possibly Damaging4.26Benign0.00Affected0.22370.28961-1-3.158.04
c.328G>A
V110I
2D
AIThe SynGAP1 missense variant V110I is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.622677Disordered0.665934Binding0.3470.8600.750-4.409Likely Benign0.103Likely BenignLikely Benign0.058Likely Benign-0.10Neutral0.012Benign0.006Benign4.26Benign0.52Tolerated0.08750.4485430.314.03
c.389A>C
Q130P
2D
AIThe SynGAP1 missense variant Q130P is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. Foldetta results are not available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.509769Disordered0.718853Binding0.3060.8850.375-0.659Likely Benign0.068Likely BenignLikely Benign0.213Likely Benign-0.10Neutral0.990Probably Damaging0.954Probably Damaging4.15Benign0.03Affected0.24140.44660-11.9-31.01
c.2320G>T
A774S
2D
AIThe SynGAP1 missense variant A774S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on current predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.450668Structured0.905168Binding0.3360.8970.250-2.780Likely Benign0.079Likely BenignLikely Benign0.090Likely Benign-0.09Neutral0.071Benign0.115Benign4.27Benign0.43Tolerated0.27110.639911-2.616.00
c.2371A>C
K791Q
2D
AIThe SynGAP1 missense variant K791Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv flags the variant as pathogenic, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports it as Likely Benign. High‑accuracy assessments confirm this trend: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that K791Q is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.966441Disordered0.478670Uncertain0.3560.8960.875-3.418Likely Benign0.195Likely BenignLikely Benign0.081Likely Benign-0.09Neutral0.802Possibly Damaging0.335Benign4.17Benign0.46Tolerated0.53220.1159Weaken110.4-0.04
c.2605C>A
L869M
2D
AIThe SynGAP1 missense variant L869M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is benign, and this conclusion does not contradict any ClinVar annotation (none present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.501700Disordered0.688653Binding0.2720.8390.250-4.294Likely Benign0.119Likely BenignLikely Benign0.093Likely Benign-0.09Neutral0.149Benign0.058Benign2.61Benign0.11Tolerated0.07100.379542-1.918.03
c.2822C>A
P941H
2D
AIThe SynGAP1 missense variant P941H is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates a likely benign outcome. In contrast, two tools—polyPhen‑2 HumDiv and SIFT—classify the change as pathogenic. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; no Foldetta stability data are available. Overall, the majority of evidence points to a benign effect, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.874069Disordered0.900790Binding0.4030.9060.625-4.439Likely Benign0.098Likely BenignLikely Benign0.058Likely Benign-0.09Neutral0.589Possibly Damaging0.309Benign2.71Benign0.00Affected0.16210.48260-2-1.640.02
c.3094C>A
L1032M
2D
AIThe SynGAP1 missense variant L1032M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of any ClinVar pathogenic annotation. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.865454Disordered0.995318Binding0.3650.7350.500-4.353Likely Benign0.219Likely BenignLikely Benign0.064Likely Benign-0.09Neutral0.995Probably Damaging0.892Possibly Damaging2.66Benign0.10Tolerated0.09350.471942-1.918.03
c.3109A>G
I1037V
2D
AIThe SynGAP1 missense variant I1037V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that I1037V is most likely benign, and this conclusion is not contradicted by ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-2.326Likely Benign0.461AmbiguousLikely Benign0.085Likely Benign-0.09Neutral0.421Benign0.128Benign2.76Benign0.93Tolerated0.12290.398543-0.3-14.03
c.3163G>A
G1055R
2D
AIThe SynGAP1 missense variant G1055R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors benign, while Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.982235Disordered0.872113Binding0.3790.9350.875-8.778Likely Pathogenic0.375AmbiguousLikely Benign0.275Likely Benign-0.09Neutral0.970Probably Damaging0.728Possibly Damaging3.31Benign0.08Tolerated0.10130.4733-3-2-4.199.14
c.3163G>C
G1055R
2D
AIThe SynGAP1 missense variant G1055R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. AlphaMissense‑Default is uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign outcome (2 benign vs. 1 pathogenic, 1 uncertain). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence indicates the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.982235Disordered0.872113Binding0.3790.9350.875-8.778Likely Pathogenic0.375AmbiguousLikely Benign0.275Likely Benign-0.09Neutral0.970Probably Damaging0.728Possibly Damaging3.31Benign0.08Tolerated0.10130.4733-3-2-4.199.14
c.37A>T
I13F
2D
AIThe SynGAP1 missense variant I13F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.486429Structured0.482657Uncertain0.3180.9160.375-3.359Likely Benign0.126Likely BenignLikely Benign0.134Likely Benign-0.09Neutral0.107Benign0.010Benign4.04Benign0.00Affected0.06540.397210-1.734.02
c.385T>C
S129P
2D
AIThe SynGAP1 missense variant S129P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of tools, including the high‑accuracy predictors, indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.517562Disordered0.713635Binding0.3110.8800.625-2.469Likely Benign0.237Likely BenignLikely Benign0.220Likely Benign-0.09Neutral0.454Possibly Damaging0.133Benign4.11Benign0.32Tolerated0.19980.49891-1-0.810.04
c.2239G>A
V747I
2D
AIThe SynGAP1 missense variant V747I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.594069Binding0.3430.8730.750-3.981Likely Benign0.071Likely BenignLikely Benign0.038Likely Benign-0.08Neutral0.002Benign0.008Benign2.70Benign0.00Affected0.05600.3018430.314.03
c.2846G>C
G949A
2D
AIThe SynGAP1 missense variant G949A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is “Likely Benign” (3 benign vs. 1 pathogenic votes). High‑accuracy methods confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988861Disordered0.874971Binding0.3650.9230.750-6.838Likely Benign0.072Likely BenignLikely Benign0.274Likely Benign-0.08Neutral0.779Possibly Damaging0.425Benign2.28Pathogenic0.08Tolerated0.33850.4414102.214.03
c.2975T>C
V992A
2D
AIThe SynGAP1 missense variant V992A is not reported in ClinVar and is absent from gnomAD. Prediction tools that assess pathogenicity all converge on a benign outcome: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. No tool in the dataset indicates a pathogenic effect. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Based on the collective predictions, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.921728Binding0.3310.9170.750-2.607Likely Benign0.082Likely BenignLikely Benign0.069Likely Benign-0.08Neutral0.000Benign0.003Benign4.29Benign0.41Tolerated0.30410.266800-2.4-28.05
c.308G>C
G103A
2D
AIThe SynGAP1 missense variant G103A is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta results are not available, so they do not influence the assessment. Overall, the majority of evidence points to a benign impact, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.687376Binding0.3810.8770.625-3.549Likely Benign0.092Likely BenignLikely Benign0.118Likely Benign-0.08Neutral0.008Benign0.008Benign4.31Benign0.00Affected0.39410.3784102.214.03
c.3178G>A
G1060S
2D
AIThe SynGAP1 missense variant G1060S is listed in ClinVar with an uncertain significance (ClinVar ID 1512003.0) and is present in gnomAD (variant ID 6‑33443730‑G‑A). All evaluated in‑silico predictors classify the change as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this benign view: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the computational evidence overwhelmingly supports a benign effect, which is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979242Disordered0.913048Binding0.4070.9280.875Uncertain 16-33443730-G-A-4.759Likely Benign0.082Likely BenignLikely Benign0.376Likely Benign-0.08Neutral0.271Benign0.054Benign2.69Benign0.49Tolerated4.3220.24680.531110-0.430.03
c.3364G>A
G1122S
2D
AIThe SynGAP1 missense variant G1122S is listed in ClinVar (ID 643187) as Benign and is present in gnomAD (6‑33443916‑G‑A). Prediction tools that assess pathogenicity all converge on a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign. No tool predicts pathogenicity. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized indicates Benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports Likely Benign. The Foldetta stability analysis is unavailable for this variant. Overall, the computational evidence overwhelmingly supports a benign effect, aligning with the ClinVar classification and showing no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.896620Disordered0.814918Binding0.3570.9320.875Benign/Likely benign 36-33443916-G-A271.79e-5-4.880Likely Benign0.072Likely BenignLikely Benign0.189Likely Benign-0.08Neutral0.022Benign0.006Benign4.89Benign0.92Tolerated3.7750.25370.511110-0.430.03
c.3757G>A
A1253T
2D
AISynGAP1 missense variant A1253T is predicted to be benign by all evaluated in‑silico tools. The consensus group of predictors—REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—uniformly classify the change as benign, with no tool indicating pathogenicity. High‑accuracy methods corroborate this view: AlphaMissense‑Optimized reports a benign effect, and the SGM Consensus (a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also labels the variant as likely benign. Foldetta stability analysis is unavailable. ClinVar contains no entry for this variant, and it is not present in gnomAD. Overall, the predictive evidence strongly supports a benign classification, consistent with the lack of a ClinVar pathogenic report.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.661982Disordered0.391377Uncertain0.8810.5500.750-4.116Likely Benign0.077Likely BenignLikely Benign0.046Likely Benign-0.08Neutral0.042Benign0.061Benign2.79Benign0.41Tolerated0.10160.533910-2.530.03
c.385T>G
S129A
2D
AIThe SynGAP1 missense variant S129A is not reported in ClinVar and is absent from gnomAD. All evaluated in‑silico predictors—including REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—classify the change as benign. No tool predicts pathogenicity. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus itself is benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.517562Disordered0.713635Binding0.3110.8800.625-3.388Likely Benign0.134Likely BenignLikely Benign0.090Likely Benign-0.08Neutral0.007Benign0.007Benign4.21Benign0.15Tolerated0.50310.4619Weaken112.6-16.00
c.43G>A
A15T
2D
AIThe SynGAP1 missense variant A15T is listed in ClinVar (ID 1925632.0) with an “Uncertain” clinical significance and is present in gnomAD (6‑33420307‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as “Likely Benign”; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which remains uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.436924Structured0.466055Uncertain0.3300.9120.375Uncertain 16-33420307-G-A42.60e-6-3.720Likely Benign0.125Likely BenignLikely Benign0.086Likely Benign-0.08Neutral0.602Possibly Damaging0.017Benign4.16Benign0.00Affected4.3210.20530.742310-2.530.03
c.56C>A
A19D
2D
AIThe SynGAP1 missense variant A19D is listed in gnomAD (ID 6‑33420320‑C‑A) but has no ClinVar entry. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.529623Disordered0.443393Uncertain0.3780.9060.5006-33420320-C-A21.30e-6-3.746Likely Benign0.573Likely PathogenicLikely Benign0.055Likely Benign-0.08Neutral0.588Possibly Damaging0.054Benign4.07Benign0.00Affected4.3210.25080.2734-20-5.344.01
c.1210G>T
A404S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A404S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; no tool predicts a pathogenic outcome. The high‑accuracy assessments are consistent: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also predicts benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) indicates a benign effect. No inconclusive or missing predictions are present. Based on the unanimous benign predictions and the lack of ClinVar evidence, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.232838Structured0.415505Uncertain0.9650.3550.000-1.937Likely Benign0.194Likely BenignLikely Benign0.13Likely Benign0.00.83Ambiguous0.48Likely Benign0.28Likely Benign0.078Likely Benign-0.07Neutral0.000Benign0.001Benign4.18Benign0.22Tolerated0.29700.617811-2.616.00
c.169C>A
L57I
2D
AIThe SynGAP1 missense variant L57I is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized returns Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability prediction is available. Overall, the majority of evidence points to a benign effect for the L57I variant, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.254060Structured0.481044Uncertain0.5540.6420.000-3.681Likely Benign0.275Likely BenignLikely Benign0.024Likely Benign-0.07Neutral0.458Possibly Damaging0.745Possibly Damaging4.10Benign0.00Affected0.09730.4106220.70.00
c.24C>G
I8M
2D
AIThe SynGAP1 missense variant I8M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus, SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign status. Foldetta, a protein‑folding stability method that combines FoldX‑MD and Rosetta outputs, was not available for this variant. Overall, the majority of evidence points to a benign effect, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.490133Structured0.543080Binding0.3410.9160.625-3.957Likely Benign0.140Likely BenignLikely Benign0.085Likely Benign-0.07Neutral0.296Benign0.022Benign4.02Benign0.00Affected0.06260.303421-2.618.03
c.2548G>A
G850R
2D
AIThe SynGAP1 missense variant G850R is listed in ClinVar with an uncertain significance (ClinVar ID 2042462.0) and is not reported in gnomAD. Prediction tools that classify the variant as benign include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only SIFT predicts a pathogenic effect, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized labeling the variant as benign and the SGM‑Consensus indicating a likely benign outcome; Foldetta, a protein‑folding stability method, did not provide a result for this substitution. Overall, the preponderance of evidence points to a benign impact, which aligns with the ClinVar designation of uncertain significance rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.648219Disordered0.540897Binding0.3120.8200.500Uncertain 1-5.082Likely Benign0.398AmbiguousLikely Benign0.194Likely Benign-0.07Neutral0.010Benign0.010Benign4.30Benign0.01Affected3.7750.10110.4476-3-2-4.199.14
c.2548G>C
G850R
2D
AIThe SynGAP1 missense variant G850R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus (SGM‑Consensus) derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN is “Likely Benign.” AlphaMissense‑Optimized also reports a benign prediction. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.648219Disordered0.540897Binding0.3120.8200.500-5.082Likely Benign0.398AmbiguousLikely Benign0.194Likely Benign-0.07Neutral0.010Benign0.010Benign4.30Benign0.01Affected3.7750.10110.4476-3-2-4.199.14
c.2806G>T
A936S
2D
AIThe SynGAP1 missense variant A936S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are unavailable. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.973218Binding0.3190.8740.625-3.555Likely Benign0.065Likely BenignLikely Benign0.057Likely Benign-0.07Neutral0.022Benign0.008Benign2.53Benign0.11Tolerated0.26750.530011-2.616.00
c.2833C>T
H945Y
2D
AIThe SynGAP1 missense variant H945Y is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability result is available. Overall, the majority of evidence points to a benign effect for H945Y, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.750-6.036Likely Benign0.112Likely BenignLikely Benign0.335Likely Benign-0.07Neutral0.982Probably Damaging0.903Possibly Damaging5.27Benign0.05Affected0.21020.3912021.926.03
c.3043A>G
T1015A
2D
AIThe SynGAP1 missense variant T1015A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate a benign effect. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is benign, and this conclusion does not contradict any ClinVar status (none reported). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.928486Binding0.2950.8230.625-2.615Likely Benign0.065Likely BenignLikely Benign0.066Likely Benign-0.07Neutral0.001Benign0.002Benign2.73Benign0.54Tolerated0.39600.3949102.5-30.03
c.3082C>A
L1028M
2D
AIThe SynGAP1 missense variant L1028M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect for the variant, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.899122Disordered0.995137Binding0.3640.7300.500-4.591Likely Benign0.229Likely BenignLikely Benign0.082Likely Benign-0.07Neutral0.986Probably Damaging0.825Possibly Damaging2.70Benign0.18Tolerated0.07760.312442-1.918.03
c.3802C>A
L1268M
2D
AIThe SynGAP1 missense variant L1268M is reported in gnomAD (ID 6‑33447850‑C‑A) and has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; a Foldetta stability analysis is not available. Overall, the preponderance of evidence from multiple in silico predictors and consensus methods indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.458154Structured0.804315Binding0.8590.6290.0006-33447850-C-A-4.689Likely Benign0.140Likely BenignLikely Benign0.062Likely Benign-0.07Neutral0.990Probably Damaging0.796Possibly Damaging2.67Benign0.08Tolerated3.7750.06270.229724-1.918.03
c.46A>G
M16V
2D
AIThe SynGAP1 missense variant M16V is reported in gnomAD (ID 6‑33420310‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign status. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for M16V, and this conclusion does not contradict any ClinVar classification, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.440853Structured0.459925Uncertain0.3460.9080.3756-33420310-A-G161.05e-5-1.595Likely Benign0.128Likely BenignLikely Benign0.073Likely Benign-0.07Neutral0.000Benign0.000Benign4.30Benign0.00Affected4.3210.35610.3937122.3-32.06
c.1339G>A
V447I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V447I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) all indicate a benign or likely benign outcome. Only two tools, polyPhen‑2 HumDiv and HumVar, predict a pathogenic effect. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign, the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is likely benign, and Foldetta (combining FoldX‑MD and Rosetta) predicts benign stability. Thus, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.250310Structured0.283801Uncertain0.9700.2430.000-5.067Likely Benign0.167Likely BenignLikely Benign-0.33Likely Benign0.10.27Likely Benign-0.03Likely Benign-0.44Likely Benign0.117Likely Benign-0.06Neutral0.947Possibly Damaging0.851Possibly Damaging3.37Benign0.28Tolerated0.06250.3059430.314.03
c.14G>A
R5Q
2D
AIThe SynGAP1 missense variant R5Q is reported in gnomAD (variant ID 6‑33420278‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the consensus of the majority of tools, including the high‑accuracy methods, points to a benign impact. This prediction does not contradict any ClinVar status, as none is available.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.595080Disordered0.547847Binding0.3630.9200.7506-33420278-G-A21.30e-6-4.261Likely Benign0.223Likely BenignLikely Benign0.094Likely Benign-0.06Neutral0.403Benign0.007Benign4.15Benign0.00Affected4.3210.37400.3122111.0-28.06
c.14G>T
R5L
2D
AIThe SynGAP1 missense variant R5L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.595080Disordered0.547847Binding0.3630.9200.750-3.297Likely Benign0.274Likely BenignLikely Benign0.158Likely Benign-0.06Neutral0.030Benign0.003Benign4.14Benign0.00Affected0.22560.5914-3-28.3-43.03
c.2632A>T
T878S
2D
AIThe SynGAP1 missense variant T878S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.622677Disordered0.628767Binding0.2880.8780.250-2.493Likely Benign0.088Likely BenignLikely Benign0.073Likely Benign-0.06Neutral0.009Benign0.012Benign2.82Benign0.03Affected0.35570.486711-0.1-14.03
c.2852A>C
H951P
2D
AIThe SynGAP1 missense variant H951P is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign classification, and this conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-2.798Likely Benign0.051Likely BenignLikely Benign0.312Likely Benign-0.06Neutral0.000Benign0.001Benign5.43Benign0.14Tolerated0.27450.37070-21.6-40.02
c.2968T>A
S990T
2D
AIThe SynGAP1 missense variant S990T is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.902387Binding0.3010.9190.750-4.439Likely Benign0.073Likely BenignLikely Benign0.026Likely Benign-0.06Neutral0.001Benign0.007Benign2.89Benign1.00Tolerated0.15240.5598110.114.03
c.3451T>A
S1151T
2D
AIThe SynGAP1 missense variant S1151T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic effect. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.741537Disordered0.805072Binding0.3940.8390.625-3.874Likely Benign0.124Likely BenignLikely Benign0.080Likely Benign-0.06Neutral0.798Possibly Damaging0.535Possibly Damaging2.72Benign0.30Tolerated0.14500.5903110.114.03
c.361G>T
A121S
2D
AIThe SynGAP1 missense variant A121S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods also support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable. Overall, the collective predictions strongly suggest that the variant is most likely benign, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.779859Disordered0.661304Binding0.3620.8880.750-3.027Likely Benign0.078Likely BenignLikely Benign0.067Likely Benign-0.06Neutral0.002Benign0.002Benign4.18Benign0.40Tolerated0.28050.581711-2.616.00
c.104T>C
V35A
2D
AIThe SynGAP1 missense variant V35A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumDiv, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools, polyPhen‑2 HumVar and SIFT, predict pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.613573Disordered0.434838Uncertain0.3600.8510.375-3.552Likely Benign0.120Likely BenignLikely Benign0.098Likely Benign-0.05Neutral0.267Benign0.481Possibly Damaging4.25Benign0.00Affected0.23400.214400-2.4-28.05
c.1604G>A
S535N
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S535N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Across the broad panel of in‑silico predictors, 13 tools (REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus “Likely Benign”) uniformly predict a benign effect, whereas only FATHMM assigns a pathogenic label. High‑accuracy assessments corroborate the benign consensus: AlphaMissense‑Optimized is benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is “Likely Benign,” and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts benign stability. Thus, the variant is most likely benign based on the available predictions, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.236433Structured0.041365Uncertain0.9180.3430.000-4.957Likely Benign0.196Likely BenignLikely Benign-0.46Likely Benign0.2-0.26Likely Benign-0.36Likely Benign0.18Likely Benign0.176Likely Benign-0.05Neutral0.070Benign0.032Benign-1.25Pathogenic0.29Tolerated0.13900.478411-2.727.03
c.1852C>A
Q618K
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q618K is not reported in ClinVar (ClinVar ID None) but is present in gnomAD (ID 6‑33440904‑C‑A). Functional prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while ESM1b is uncertain. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign result; and Foldetta also predicts benign stability. No predictions or folding stability results are missing or inconclusive. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.175930Structured0.138725Uncertain0.9040.2400.0006-33440904-C-A241.49e-5-7.708In-Between0.229Likely BenignLikely Benign0.02Likely Benign0.00.16Likely Benign0.09Likely Benign-0.46Likely Benign0.281Likely Benign-0.05Neutral0.338Benign0.111Benign-1.21Pathogenic0.29Tolerated3.37350.14130.275011-0.40.04
c.192A>G
I64M
2D
AIThe SynGAP1 missense variant I64M is listed in gnomAD (ID 6‑33425800‑A‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.422041Structured0.475481Uncertain0.4780.7470.1256-33425800-A-G21.24e-6-4.327Likely Benign0.523AmbiguousLikely Benign0.047Likely Benign-0.05Neutral0.637Possibly Damaging0.047Benign4.04Benign0.00Affected4.3210.05680.231012-2.618.03
c.2257G>C
A753P
2D
AIThe SynGAP1 missense variant A753P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this is consistent with the lack of ClinVar annotation—there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.521092Disordered0.722781Binding0.3810.8730.625-2.486Likely Benign0.105Likely BenignLikely Benign0.113Likely Benign-0.05Neutral0.966Probably Damaging0.575Possibly Damaging2.59Benign0.30Tolerated0.21430.54421-1-3.426.04
c.2746G>A
V916I
2D
AIThe SynGAP1 missense variant V916I is reported in gnomAD (variant ID 6-33443298‑G‑A) but has no ClinVar entry. Functional prediction tools uniformly classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate a benign effect. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the evidence strongly supports a benign classification, and this assessment is consistent with the absence of a ClinVar pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.642678Disordered0.835395Binding0.3080.8790.2506-33443298-G-A251.55e-5-4.336Likely Benign0.074Likely BenignLikely Benign0.062Likely Benign-0.05Neutral0.010Benign0.015Benign2.71Benign0.09Tolerated3.7750.09050.4463340.314.03
c.27T>A
H9Q
2D
AIThe SynGAP1 missense variant H9Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and AlphaMissense‑Optimized also reports a benign prediction. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. The variant is most likely benign, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.486429Structured0.528099Binding0.3940.9160.750-3.477Likely Benign0.117Likely BenignLikely Benign0.069Likely Benign-0.05Neutral0.000Benign0.000Benign4.24Benign0.00Affected0.20740.429730-0.3-9.01
c.27T>G
H9Q
2D
AIThe SynGAP1 missense variant H9Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and AlphaMissense‑Optimized also reports a benign prediction. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. The variant is most likely benign, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.486429Structured0.528099Binding0.3940.9160.750-3.477Likely Benign0.117Likely BenignLikely Benign0.071Likely Benign-0.05Neutral0.000Benign0.000Benign4.24Benign0.00Affected0.20740.429730-0.3-9.01
c.2936T>C
F979S
2D
AIThe SynGAP1 missense variant F979S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and the AlphaMissense‑Optimized score also indicates a benign outcome. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation because no ClinVar entry exists for F979S.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.977500Binding0.2740.8890.625-2.350Likely Benign0.718Likely PathogenicLikely Benign0.211Likely Benign-0.05Neutral0.451Benign0.220Benign4.23Benign0.01Affected0.43970.0384-3-2-3.6-60.10
c.29G>C
R10P
2D
AIThe SynGAP1 missense variant R10P is listed in ClinVar with an uncertain significance and is present in gnomAD (ID 6‑33420293‑G‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority of the four high‑accuracy tools) is benign; Foldetta results are unavailable. Overall, the collective evidence points to a benign effect for R10P, which does not contradict the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.513657Binding0.3300.9150.625Uncertain 26-33420293-G-C21.30e-6-3.772Likely Benign0.162Likely BenignLikely Benign0.220Likely Benign-0.05Neutral0.233Benign0.026Benign4.13Benign0.00Affected4.3210.22610.52450-22.9-59.07
c.3097T>A
S1033T
2D
AIThe SynGAP1 missense variant S1033T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.910643Disordered0.993473Binding0.2940.7370.625-3.702Likely Benign0.140Likely BenignLikely Benign0.029Likely Benign-0.05Neutral0.568Possibly Damaging0.171Benign2.73Benign0.58Tolerated0.13790.6089110.114.03
c.3161G>C
G1054A
2D
AIThe SynGAP1 missense variant G1054A is catalogued in gnomAD (ID 6‑33443713‑G‑C) but has no ClinVar entry. Across a broad panel of in‑silico predictors, every tool reports a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity, so the pathogenic‑prediction group is empty. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no reported result for this variant, so its status is unavailable. Based on the unanimous benign predictions and the lack of any ClinVar pathogenic classification, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.878015Binding0.3890.9360.8756-33443713-G-C-6.786Likely Benign0.078Likely BenignLikely Benign0.243Likely Benign-0.05Neutral0.288Benign0.071Benign4.03Benign1.00Tolerated3.7750.33050.5144012.214.03
c.3364G>C
G1122R
2D
AIThe SynGAP1 missense variant G1122R is not reported in ClinVar (ClinVar status: not listed) and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, polyPhen‑2 HumVar, and FATHMM, while pathogenic predictions arise from polyPhen‑2 HumDiv, SIFT, and ESM1b; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence (six benign versus three pathogenic predictions, plus a benign consensus) indicates that the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.896620Disordered0.814918Binding0.3570.9320.875-9.063Likely Pathogenic0.507AmbiguousLikely Benign0.319Likely Benign-0.05Neutral0.639Possibly Damaging0.351Benign4.64Benign0.05Affected0.09760.4342-3-2-4.199.14
c.347A>C
Y116S
2D
AIThe SynGAP1 missense variant Y116S is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions strongly suggests that Y116S is most likely benign, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.661982Disordered0.670235Binding0.3810.8780.625-0.249Likely Benign0.269Likely BenignLikely Benign0.178Likely Benign-0.05Neutral0.033Benign0.013Benign4.31Benign0.58Tolerated0.51110.1694Weaken-3-20.5-76.10
c.3931C>G
L1311V
2D
AIThe SynGAP1 missense variant L1311V is catalogued in gnomAD (ID 6‑33451805‑C‑G) but has no ClinVar entry. Across a broad panel of in silico predictors, every tool reports a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool in the set predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized returns a benign prediction, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—labels the variant as Likely Benign. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status remains unavailable. Overall, the computational evidence overwhelmingly supports a benign impact, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.968153Binding0.3930.9070.7506-33451805-C-G16.20e-7-3.645Likely Benign0.066Likely BenignLikely Benign0.025Likely Benign-0.05Neutral0.362Benign0.193Benign2.89Benign0.32Tolerated3.7750.16660.3518120.4-14.03
c.209G>A
R70Q
2D
AIThe SynGAP1 missense variant R70Q is reported in gnomAD (variant ID 6-33425817‑G‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: the majority (REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized) indicate a benign effect, while a minority (polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT) predict pathogenicity. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized classifies the variant as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports it as Likely Benign. No Foldetta stability data are available, so it does not influence the conclusion. Overall, the preponderance of evidence from both general and high‑accuracy predictors points to a benign impact. This assessment is not in conflict with ClinVar, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.458981Uncertain0.3920.7930.3756-33425817-G-A16.20e-7-3.399Likely Benign0.180Likely BenignLikely Benign0.109Likely Benign-0.04Neutral0.983Probably Damaging0.602Possibly Damaging4.25Benign0.00Affected4.3210.25120.2506111.0-28.06
c.2269G>C
G757R
2D
AIThe SynGAP1 missense variant G757R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic outcome. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports likely benign; Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.436924Structured0.830995Binding0.3100.8690.375-2.254Likely Benign0.534AmbiguousLikely Benign0.158Likely Benign-0.04Neutral0.801Possibly Damaging0.494Possibly Damaging2.79Benign0.05Affected0.09030.3481-3-2-4.199.14
c.2390C>A
P797Q
2D
AIThe SynGAP1 missense variant P797Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. Thus, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.926919Disordered0.449970Uncertain0.5610.9020.875-6.201Likely Benign0.081Likely BenignLikely Benign0.066Likely Benign-0.04Neutral0.940Possibly Damaging0.801Possibly Damaging4.23Benign0.15Tolerated0.16360.47870-1-1.931.01
c.26A>G
H9R
2D
AIThe SynGAP1 missense variant H9R is reported in gnomAD (variant ID 6‑33420290‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that H9R is most likely benign, and this conclusion does not contradict any ClinVar status (none is provided).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.486429Structured0.528099Binding0.3940.9160.7506-33420290-A-G-1.736Likely Benign0.112Likely BenignLikely Benign0.113Likely Benign-0.04Neutral0.012Benign0.002Benign4.25Benign0.00Affected4.3210.23300.326602-1.319.05
c.2732T>G
V911G
2D
AIThe SynGAP1 missense variant V911G is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). All available in silico predictors classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity, so the benign group includes every listed predictor, while the pathogenic group is empty. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign; the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields a benign verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, is not available for this variant. Overall, the computational evidence overwhelmingly supports a benign effect, and this conclusion does not contradict any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.685117Disordered0.724137Binding0.3270.9140.375-2.754Likely Benign0.222Likely BenignLikely Benign0.124Likely Benign-0.04Neutral0.004Benign0.003Benign2.74Benign0.16Tolerated0.23070.3360-1-3-4.6-42.08
c.2752G>T
A918S
2D
AIThe SynGAP1 missense variant A918S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). In contrast, the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is also likely benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence indicates that A918S is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.632174Disordered0.891459Binding0.3170.8600.250-3.279Likely Benign0.070Likely BenignLikely Benign0.058Likely Benign-0.04Neutral0.910Possibly Damaging0.554Possibly Damaging2.66Benign0.07Tolerated0.28240.544211-2.616.00
c.3032G>C
G1011A
2D
AIThe SynGAP1 missense variant G1011A is catalogued in gnomAD (ID 6‑33443584‑G‑C) and has no ClinVar entry. All evaluated in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool reports a pathogenic outcome. High‑accuracy assessments concur: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.898380Binding0.3320.8690.6256-33443584-G-C-4.349Likely Benign0.097Likely BenignLikely Benign0.077Likely Benign-0.04Neutral0.139Benign0.089Benign2.89Benign0.64Tolerated3.7750.36410.4571012.214.03
c.3344T>C
I1115T
2D
AIThe SynGAP1 missense variant I1115T is listed in ClinVar (ID 130530) as Benign and is present in gnomAD (variant ID 6‑33443896‑T‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool in the dataset predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts Benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence strongly favors a benign impact, consistent with the ClinVar designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.892339Binding0.3080.9120.750Benign 106-33443896-T-C205361.36e-2-2.670Likely Benign0.068Likely BenignLikely Benign0.100Likely Benign-0.04Neutral0.000Benign0.001Benign2.76Benign0.23Tolerated4.3220.13970.22520-1-5.2-12.05
c.3430T>G
L1144V
2D
AIThe SynGAP1 missense variant L1144V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools, polyPhen‑2 HumDiv and HumVar, predict pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy methods reinforce this view: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.726803Binding0.2770.8401.000-4.025Likely Benign0.151Likely BenignLikely Benign0.227Likely Benign-0.04Neutral0.952Possibly Damaging0.770Possibly Damaging5.43Benign0.70Tolerated0.15530.3297210.4-14.03
c.44C>G
A15G
2D
AIThe SynGAP1 missense variant A15G is reported in gnomAD (ID 6‑33420308‑C‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus also reports likely benign; Foldetta results are not available. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods points to a benign impact. This conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.436924Structured0.466055Uncertain0.3300.9120.3756-33420308-C-G31.95e-6-3.261Likely Benign0.104Likely BenignLikely Benign0.084Likely Benign-0.04Neutral0.000Benign0.000Benign4.12Benign0.00Affected4.3210.27530.519601-2.2-14.03
c.230G>C
S77T
2D
AIThe SynGAP1 missense variant S77T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. Foldetta results are not available, so they do not influence the assessment. Overall, the majority of computational evidence points to a benign effect, and this is consistent with the lack of any ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.490133Structured0.446124Uncertain0.3100.8550.375-4.204Likely Benign0.068Likely BenignLikely Benign0.058Likely Benign-0.03Neutral0.092Benign0.007Benign4.19Benign0.00Affected0.11800.5003110.114.03
c.2767A>C
I923L
2D
AIThe SynGAP1 missense variant I923L is not reported in ClinVar and is absent from gnomAD. All evaluated in‑silico predictors—including REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods likewise support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.562014Disordered0.964857Binding0.2920.8520.250-1.637Likely Benign0.157Likely BenignLikely Benign0.069Likely Benign-0.03Neutral0.166Benign0.101Benign2.82Benign0.56Tolerated0.11330.452822-0.70.00
c.307G>A
G103S
2D
AIThe SynGAP1 missense variant G103S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.687376Binding0.3810.8770.625-3.177Likely Benign0.079Likely BenignLikely Benign0.072Likely Benign-0.03Neutral0.565Possibly Damaging0.207Benign4.32Benign0.00Affected0.28160.486710-0.430.03
c.3164G>A
G1055E
2D
AIThe SynGAP1 missense variant G1055E is catalogued in gnomAD (variant ID 6‑33443716‑G‑A) but has no ClinVar entry. In silico prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a benign effect. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.872113Binding0.3790.9350.8756-33443716-G-A16.21e-7-10.951Likely Pathogenic0.290Likely BenignLikely Benign0.320Likely Benign-0.03Neutral0.901Possibly Damaging0.456Possibly Damaging3.30Benign0.10Tolerated3.7750.15250.4459-20-3.172.06
c.367G>T
A123S
2D
AIThe SynGAP1 missense variant A123S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions strongly supports a benign classification, and this conclusion does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.521092Disordered0.689505Binding0.3240.8860.750-3.309Likely Benign0.088Likely BenignLikely Benign0.081Likely Benign-0.03Neutral0.131Benign0.039Benign4.21Benign0.28Tolerated0.29790.601111-2.616.00
c.3932T>A
L1311Q
2D
AIThe SynGAP1 missense variant L1311Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.968153Binding0.3930.9070.750-4.009Likely Benign0.100Likely BenignLikely Benign0.074Likely Benign-0.03Neutral0.579Possibly Damaging0.413Benign2.74Benign0.12Tolerated0.14760.1677-2-2-7.314.97
c.3937C>T
P1313S
2D
AIThe SynGAP1 missense variant P1313S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools that assess sequence conservation and structural impact (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized) all classify the change as benign. No tool in the dataset predicts pathogenicity. The high‑accuracy consensus methods likewise support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates “Likely Benign.” Foldetta results are not available, so they do not influence the assessment. Overall, the collective evidence strongly suggests that the variant is most likely benign, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.970301Binding0.4520.9020.750-4.279Likely Benign0.071Likely BenignLikely Benign0.067Likely Benign-0.03Neutral0.047Benign0.066Benign4.33Benign0.13Tolerated0.35200.61531-10.8-10.04
c.2662G>C
A888P
2D
AIThe SynGAP1 missense variant A888P is reported in gnomAD (variant ID 6‑33443214‑G‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence supports a benign classification for A888P, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.575860Binding0.3520.9280.6256-33443214-G-C53.10e-6-2.368Likely Benign0.083Likely BenignLikely Benign0.050Likely Benign-0.02Neutral0.000Benign0.000Benign2.56Benign0.00Affected4.3240.18590.5764-11-3.426.04
c.3586A>G
K1196E
2D
AIThe SynGAP1 missense variant K1196E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools are divided: benign predictions come from REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the absence of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.599170Disordered0.435699Uncertain0.8510.5950.250-6.382Likely Benign0.734Likely PathogenicLikely Benign0.358Likely Benign-0.02Neutral0.961Probably Damaging0.764Possibly Damaging5.38Benign0.42Tolerated0.32720.0720010.40.94
c.3895C>G
L1299V
2D
AIThe SynGAP1 missense variant L1299V is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification—there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.771762Disordered0.896323Binding0.3980.8320.750-4.502Likely Benign0.121Likely BenignLikely Benign0.385Likely Benign-0.02Neutral0.124Benign0.025Benign2.89Benign0.09Tolerated0.17260.3544210.4-14.03
c.38T>C
I13T
2D
AIThe SynGAP1 missense variant I13T is listed in gnomAD (ID 6‑33420302‑T‑C) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign and the SGM‑Consensus is “Likely Benign.” No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.486429Structured0.482657Uncertain0.3180.9160.3756-33420302-T-C-2.856Likely Benign0.385AmbiguousLikely Benign0.132Likely Benign-0.02Neutral0.024Benign0.003Benign4.07Benign0.00Affected4.3210.14010.1778-10-5.2-12.05
c.40C>T
P14S
2D
AIThe SynGAP1 missense variant P14S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.433034Structured0.471596Uncertain0.3990.9090.375-2.352Likely Benign0.123Likely BenignLikely Benign0.068Likely Benign-0.02Neutral0.212Benign0.014Benign4.23Benign0.00Affected0.39350.59381-10.8-10.04
c.55G>A
A19T
2D
AIThe SynGAP1 missense variant A19T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. The variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.529623Disordered0.443393Uncertain0.3780.9060.500-3.422Likely Benign0.131Likely BenignLikely Benign0.030Likely Benign-0.02Neutral0.371Benign0.036Benign4.14Benign0.00Affected0.23570.724810-2.530.03
c.10T>A
S4T
2D
AIThe SynGAP1 missense variant S4T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus, SGM‑Consensus, is derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, all of which are benign, and therefore SGM‑Consensus also predicts benign. AlphaMissense‑Optimized independently predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from both general and high‑accuracy tools indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.608892Disordered0.547364Binding0.3900.9240.750-4.598Likely Benign0.130Likely BenignLikely Benign0.041Likely Benign-0.01Neutral0.140Benign0.153Benign4.18Benign0.00Affected0.13830.6572110.114.03
c.1189T>A
C397S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant C397S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, FoldX, premPS, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign, while Rosetta remains uncertain. When predictions are grouped, the benign category contains all available evidence and the pathogenic category is empty. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, reports a benign effect. Consequently, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.429200Structured0.395774Uncertain0.7780.5510.250-2.324Likely Benign0.178Likely BenignLikely Benign0.37Likely Benign0.10.59Ambiguous0.48Likely Benign0.43Likely Benign0.174Likely Benign-0.01Neutral0.276Benign0.066Benign4.68Benign0.53Tolerated0.52210.2474Weaken0-1-3.3-16.06
c.1190G>C
C397S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant C397S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). In silico prediction tools that assess pathogenicity largely agree on a benign outcome: REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. No tool predicts pathogenicity; Rosetta’s assessment is uncertain and therefore treated as unavailable. High‑accuracy methods reinforce this consensus: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is benign; and Foldetta, which integrates FoldX‑MD and Rosetta outputs, is benign. Consequently, the variant is most likely benign based on the collective predictions, and this conclusion does not contradict any ClinVar status (none is assigned).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.429200Structured0.395774Uncertain0.7780.5510.250-2.324Likely Benign0.178Likely BenignLikely Benign0.37Likely Benign0.10.59Ambiguous0.48Likely Benign0.43Likely Benign0.253Likely Benign-0.01Neutral0.276Benign0.066Benign4.68Benign0.53Tolerated0.52210.2474Weaken0-1-3.3-16.06
c.1851G>C
E617D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense change E617D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that classify the variant as benign include REVEL, FoldX, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized scores the variant as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict; and Foldetta, which integrates FoldX‑MD and Rosetta stability predictions, also reports a benign effect. Based on the preponderance of evidence from both general and high‑accuracy predictors, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.111485Structured0.155123Uncertain0.8770.2400.000-1.349Likely Benign0.241Likely BenignLikely Benign0.12Likely Benign0.10.80Ambiguous0.46Likely Benign0.07Likely Benign0.322Likely Benign-0.01Neutral0.994Probably Damaging0.979Probably Damaging-1.35Pathogenic0.88Tolerated3.37350.18540.3386230.0-14.03
c.1851G>T
E617D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant E617D is listed in ClinVar with an uncertain significance (ID 2584916.0) and is not reported in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, FoldX, Foldetta, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score all indicate benign or likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and FATHMM predict a pathogenic impact, while Rosetta remains inconclusive. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign; the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is likely benign; and Foldetta, which integrates FoldX‑MD and Rosetta outputs, also predicts benign. Overall, the preponderance of evidence supports a benign classification, which does not contradict the current ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.111485Structured0.155123Uncertain0.8770.2400.000Uncertain 1-1.349Likely Benign0.241Likely BenignLikely Benign0.12Likely Benign0.10.80Ambiguous0.46Likely Benign0.07Likely Benign0.322Likely Benign-0.01Neutral0.994Probably Damaging0.979Probably Damaging-1.35Pathogenic0.88Tolerated3.37350.18540.3386230.0-14.03
c.2118A>C
E706D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant E706D is not reported in ClinVar and is absent from gnomAD. All available in‑silico predictors classify it as benign: REVEL, FoldX, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the consensus SGM score (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all indicate a benign effect. No tool predicts pathogenicity. High‑accuracy assessments likewise support a benign outcome: AlphaMissense‑Optimized is benign, the SGM Consensus is “Likely Benign,” and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts benign stability. **Thus, the variant is most likely benign, and this prediction does not contradict any ClinVar status (none is available).**

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.200174Structured0.377033Uncertain0.9290.3630.000-4.216Likely Benign0.087Likely BenignLikely Benign0.22Likely Benign0.00.02Likely Benign0.12Likely Benign-0.16Likely Benign0.182Likely Benign-0.01Neutral0.000Benign0.000Benign4.17Benign0.41Tolerated0.16810.2726320.0-14.03
c.2118A>T
E706D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant E706D is not reported in ClinVar and is absent from gnomAD. All available in‑silico predictors classify it as benign: REVEL, FoldX, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the consensus SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). No tool predicts pathogenicity. High‑accuracy assessments further support a benign effect: AlphaMissense‑Optimized predicts benign, the SGM Consensus indicates “Likely Benign,” and Foldetta (combining FoldX‑MD and Rosetta outputs) also predicts benign. With all evidence pointing to a neutral impact and no conflicting ClinVar annotation, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.200174Structured0.377033Uncertain0.9290.3630.000-4.216Likely Benign0.087Likely BenignLikely Benign0.22Likely Benign0.00.02Likely Benign0.12Likely Benign-0.16Likely Benign0.182Likely Benign-0.01Neutral0.000Benign0.000Benign4.17Benign0.41Tolerated0.16810.2726320.0-14.03
c.22A>G
I8V
2D
AIThe SynGAP1 missense variant I8V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.490133Structured0.543080Binding0.3410.9160.625-2.723Likely Benign0.081Likely BenignLikely Benign0.122Likely Benign-0.01Neutral0.005Benign0.001Benign4.22Benign0.00Affected0.10310.347043-0.3-14.03
c.2386C>A
P796T
2D
AIThe SynGAP1 P796T missense variant is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. In contrast, polyPhen‑2 HumDiv and SIFT predict pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.936162Disordered0.426363Uncertain0.4270.9000.875-5.399Likely Benign0.062Likely BenignLikely Benign0.082Likely Benign-0.01Neutral0.494Possibly Damaging0.236Benign4.26Benign0.04Affected0.17050.49610-10.93.99
c.2521G>C
V841L
2D
AIThe SynGAP1 missense variant V841L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Two tools—ESM1b and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict ClinVar status, as the variant has no ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.622677Disordered0.616495Binding0.2610.8730.125-7.924In-Between0.514AmbiguousLikely Benign0.157Likely Benign-0.01Neutral0.992Probably Damaging0.989Probably Damaging2.85Benign0.56Tolerated0.08500.423321-0.414.03
c.2521G>T
V841L
2D
AIThe SynGAP1 missense variant V841L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Two tools—ESM1b and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive, and Foldetta results are unavailable. Overall, the balance of evidence favors a benign classification, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.622677Disordered0.616495Binding0.2610.8730.125-7.924In-Between0.514AmbiguousLikely Benign0.157Likely Benign-0.01Neutral0.992Probably Damaging0.989Probably Damaging2.85Benign0.56Tolerated0.08500.423321-0.414.03
c.2900G>A
R967Q
2D
AIThe SynGAP1 missense variant R967Q is listed in ClinVar as Benign (ClinVar ID 536992.0) and is present in gnomAD (6‑33443452‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, aligning with the ClinVar classification and not contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.974374Disordered0.969686Binding0.3400.8880.750Benign/Likely benign 26-33443452-G-A311.92e-5-3.057Likely Benign0.080Likely BenignLikely Benign0.104Likely Benign-0.01Neutral0.994Probably Damaging0.626Possibly Damaging4.21Benign0.36Tolerated4.3220.31410.3446111.0-28.06
c.3697A>C
I1233L
2D
AIThe SynGAP1 missense variant I1233L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all score the substitution as benign, and AlphaMissense‑Optimized also predicts a benign outcome. No tool predicts pathogenicity; AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as likely benign. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus also indicates likely benign; Foldetta data are not available. Overall, the consensus of available predictions points to a benign effect, and this is consistent with the lack of ClinVar evidence or gnomAD observation. Thus, the variant is most likely benign, and this conclusion does not contradict ClinVar status, which has no entry for it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.525368Disordered0.564054Binding0.8810.5310.125-3.031Likely Benign0.382AmbiguousLikely Benign0.113Likely Benign-0.01Neutral0.211Benign0.108Benign2.95Benign1.00Tolerated0.06310.324622-0.70.00
c.3775A>C
I1259L
2D
AIThe SynGAP1 missense variant I1259L is not reported in ClinVar and has no entries in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and AlphaMissense‑Default predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign effect for I1259L, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.494003Structured0.576405Binding0.8850.5740.250-5.822Likely Benign0.770Likely PathogenicLikely Benign0.152Likely Benign-0.01Neutral0.981Probably Damaging0.970Probably Damaging2.80Benign0.18Tolerated0.06390.307822-0.70.00
c.40C>G
P14A
2D
AIThe SynGAP1 missense variant P14A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign status: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign. Foldetta results are unavailable. Overall, the majority of computational evidence indicates that P14A is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.433034Structured0.471596Uncertain0.3990.9090.375-2.919Likely Benign0.096Likely BenignLikely Benign0.078Likely Benign-0.01Neutral0.100Benign0.007Benign4.24Benign0.00Affected0.39280.55431-13.4-26.04
c.1096A>T
T366S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T366S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while Rosetta and Foldetta are inconclusive. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Benign, and Foldetta as uncertain. Overall, the majority of evidence points to a benign effect. There is no conflict with ClinVar status, as the variant is not yet classified in that database.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.414856Structured0.441902Uncertain0.8970.6420.250-3.273Likely Benign0.085Likely BenignLikely Benign0.13Likely Benign0.10.92Ambiguous0.53Ambiguous0.27Likely Benign0.058Likely Benign0.00Neutral0.005Benign0.001Benign1.73Pathogenic0.78Tolerated0.35490.487811-0.1-14.03
c.1097C>G
T366S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T366S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while Rosetta and Foldetta are inconclusive. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Benign, and Foldetta as uncertain. Overall, the majority of evidence points to a benign effect. There is no conflict with ClinVar status, as the variant is not yet classified in that database.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.414856Structured0.441902Uncertain0.8970.6420.250-3.273Likely Benign0.085Likely BenignLikely Benign0.13Likely Benign0.10.92Ambiguous0.53Ambiguous0.27Likely Benign0.051Likely Benign0.00Neutral0.005Benign0.001Benign1.73Pathogenic0.78Tolerated0.35490.487811-0.1-14.03
c.1585A>C
I529L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I529L is listed in gnomAD (variant ID 6‑33438828‑A‑C) but has no ClinVar entry. Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support benignity: AlphaMissense‑Optimized is benign; the SGM‑Consensus (majority vote) is benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, is benign. No prediction or folding result is missing or inconclusive. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.318242Structured0.019545Uncertain0.9010.4030.0006-33438828-A-C16.20e-70.920Likely Benign0.066Likely BenignLikely Benign-0.13Likely Benign0.0-0.11Likely Benign-0.12Likely Benign-0.21Likely Benign0.309Likely Benign0.00Neutral0.001Benign0.022Benign-1.24Pathogenic0.48Tolerated3.37350.08190.378922-0.70.00
c.2341A>G
M781V
2D
AIThe SynGAP1 missense variant M781V is catalogued in gnomAD (ID 6‑33442893‑A‑G) but has no ClinVar entry. Across the spectrum of in‑silico predictors, every tool examined—REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—consistently classifies the substitution as benign. No pathogenic predictions are reported. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Overall, the evidence overwhelmingly supports a benign effect, and this conclusion does not contradict any ClinVar status, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.580690Disordered0.792850Binding0.3420.8890.6256-33442893-A-G42.48e-6-2.624Likely Benign0.068Likely BenignLikely Benign0.174Likely Benign0.00Neutral0.000Benign0.001Benign3.03Benign0.90Tolerated3.6460.30810.2705122.3-32.06
c.2390C>G
P797R
2D
AIThe SynGAP1 missense variant P797R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate a benign effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports “Likely Benign.” No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome; Foldetta results are not available. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.926919Disordered0.449970Uncertain0.5610.9020.875-5.642Likely Benign0.179Likely BenignLikely Benign0.045Likely Benign0.00Neutral0.006Benign0.026Benign4.28Benign0.20Tolerated0.15490.30850-2-2.959.07
c.307G>C
G103R
2D
AIThe SynGAP1 missense variant G103R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.687376Binding0.3810.8770.625-3.384Likely Benign0.710Likely PathogenicLikely Benign0.100Likely Benign0.00Neutral0.949Possibly Damaging0.708Possibly Damaging4.27Benign0.00Affected0.11980.4362-3-2-4.199.14
c.34A>T
S12C
2D
AIThe SynGAP1 missense variant S12C is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools largely support a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. In contrast, two tools—polyPhen‑2 HumDiv and SIFT—predict a pathogenic impact. High‑accuracy methods give a consistent benign signal: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this is not in conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.490599Uncertain0.3550.9160.500-5.413Likely Benign0.119Likely BenignLikely Benign0.101Likely Benign0.00Neutral0.872Possibly Damaging0.206Benign4.05Benign0.00Affected0.10250.60920-13.316.06
c.8G>T
R3M
2D
AIThe SynGAP1 missense variant R3M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. The high‑accuracy consensus methods give a consistent benign signal: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign,” and Foldetta data are unavailable. Overall, the majority of evidence supports a benign classification, and this conclusion does not contradict the ClinVar status, which is currently unreported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.538167Disordered0.550331Binding0.3580.9200.875-4.655Likely Benign0.618Likely PathogenicLikely Benign0.097Likely Benign0.00Neutral0.872Possibly Damaging0.162Benign3.96Benign0.00Affected0.19060.47950-16.4-24.99
c.3090C>A
H1030Q
2D
AIThe SynGAP1 missense variant H1030Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.995856Binding0.3750.7350.500-2.548Likely Benign0.185Likely BenignLikely Benign0.033Likely Benign0.01Neutral0.004Benign0.004Benign2.88Benign0.53Tolerated0.15380.400130-0.3-9.01
c.3090C>G
H1030Q
2D
AIThe SynGAP1 missense variant H1030Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.995856Binding0.3750.7350.500-2.548Likely Benign0.185Likely BenignLikely Benign0.033Likely Benign0.01Neutral0.004Benign0.004Benign2.88Benign0.53Tolerated0.15380.400130-0.3-9.01
c.3238G>T
A1080S
2D
AIThe SynGAP1 missense variant A1080S is listed in ClinVar (ID 2703014.0) with an “Uncertain” status and is present in gnomAD (variant ID 6‑33443790‑G‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign effect, and this conclusion does not contradict the ClinVar designation, which remains uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.912647Disordered0.981457Binding0.3030.9000.750Uncertain 16-33443790-G-T16.26e-7-3.277Likely Benign0.108Likely BenignLikely Benign0.103Likely Benign0.01Neutral0.702Possibly Damaging0.346Benign4.16Benign0.08Tolerated3.7750.24980.591511-2.616.00
c.37A>G
I13V
2D
AIThe SynGAP1 I13V missense variant is listed in ClinVar (ID 3364831.0) with an “Uncertain” status and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for I13V, and this conclusion does not conflict with the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.486429Structured0.482657Uncertain0.3180.9160.375Uncertain 1-2.497Likely Benign0.105Likely BenignLikely Benign0.110Likely Benign0.01Neutral0.000Benign0.000Benign4.25Benign0.00Affected0.15480.431543-0.3-14.03
c.3941C>G
P1314R
2D
AIThe SynGAP1 missense variant P1314R is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign likelihood. Foldetta results are not available, so they do not influence the overall assessment. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.971592Binding0.4670.9030.750-4.234Likely Benign0.168Likely BenignLikely Benign0.036Likely Benign0.01Neutral0.618Possibly Damaging0.206Benign4.25Benign0.09Tolerated0.16340.34050-2-2.959.07
c.66A>C
R22S
2D
AIThe SynGAP1 missense variant R22S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; a Foldetta stability prediction is unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.538167Disordered0.441505Uncertain0.3770.8910.500-3.419Likely Benign0.602Likely PathogenicLikely Benign0.190Likely Benign0.01Neutral0.462Possibly Damaging0.227Benign4.28Benign0.00Affected4.3210.32520.5187-103.7-69.11
c.66A>T
R22S
2D
AIThe SynGAP1 missense variant R22S is listed in gnomAD (ID 6‑33420330‑A‑T) but has no ClinVar entry. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no reported result for this variant, so its stability impact is unavailable. Overall, the majority of evidence points to a benign effect, and this is not in conflict with ClinVar, which has no classification for R22S.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.538167Disordered0.441505Uncertain0.3770.8910.5006-33420330-A-T-3.419Likely Benign0.602Likely PathogenicLikely Benign0.190Likely Benign0.01Neutral0.462Possibly Damaging0.227Benign4.28Benign0.00Affected4.3210.32520.5187-103.7-69.11
c.10T>G
S4A
2D
AIThe SynGAP1 missense variant S4A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for S4A, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.608892Disordered0.547364Binding0.3900.9240.750-4.245Likely Benign0.111Likely BenignLikely Benign0.050Likely Benign0.02Neutral0.140Benign0.097Benign4.22Benign0.00Affected0.48710.5755112.6-16.00
c.2122C>A
L708I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L708I is not reported in ClinVar and is absent from gnomAD. All available in‑silico predictors classify the substitution as benign: SIFT, PolyPhen‑2 (HumDiv and HumVar), REVEL, PROVEAN, premPS, FoldX, Rosetta, AlphaMissense‑Default, AlphaMissense‑Optimized, ESM1b, and FATHMM. No tool predicts pathogenicity. High‑accuracy assessments concur: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also reports a benign effect. Consequently, the variant is most likely benign based on current predictions, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.250310Structured0.365875Uncertain0.9310.3780.000-4.406Likely Benign0.116Likely BenignLikely Benign0.42Likely Benign0.0-0.21Likely Benign0.11Likely Benign-0.05Likely Benign0.108Likely Benign0.02Neutral0.022Benign0.021Benign3.34Benign0.20Tolerated0.07490.2729220.70.00
c.2818G>C
G940R
2D
AIThe SynGAP1 missense variant G940R is listed in ClinVar (ID 1923639.0) as Benign and is present in gnomAD (6‑33443370‑G‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and Foldetta (FoldX‑MD/Rosetta stability assessment) has no available result for this variant. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as likely benign, and Foldetta data is unavailable. Overall, the majority of evidence points to a benign impact, which is consistent with the ClinVar classification and does not contradict it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.920635Binding0.3830.9020.625Benign 16-33443370-G-C53.10e-6-6.169Likely Benign0.480AmbiguousLikely Benign0.060Likely Benign0.02Neutral0.922Possibly Damaging0.543Possibly Damaging2.73Benign0.15Tolerated3.7750.09220.4024-3-2-4.199.14
c.2981A>G
K994R
2D
AIThe SynGAP1 missense variant K994R is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.930054Binding0.2890.9120.750-1.990Likely Benign0.076Likely BenignLikely Benign0.071Likely Benign0.02Neutral0.001Benign0.001Benign4.21Benign0.47Tolerated0.50640.1657Weaken32-0.628.01
c.3226T>A
L1076M
2D
AIThe SynGAP1 missense variant L1076M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of predictions (six benign vs. four pathogenic) lean toward a benign interpretation. Thus, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.989617Binding0.3010.8920.750-5.047Likely Benign0.320Likely BenignLikely Benign0.087Likely Benign0.02Neutral0.999Probably Damaging0.995Probably Damaging2.42Pathogenic0.04Affected0.08860.414742-1.918.03
c.474G>C
Q158H
2D
AIThe SynGAP1 missense variant Q158H is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.527565Binding0.2860.7500.375-2.990Likely Benign0.114Likely BenignLikely Benign0.084Likely Benign0.02Neutral0.000Benign0.001Benign4.19Benign0.51Tolerated0.14030.3774300.39.01
c.474G>T
Q158H
2D
AIThe SynGAP1 missense variant Q158H is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.527565Binding0.2860.7500.375-2.990Likely Benign0.114Likely BenignLikely Benign0.084Likely Benign0.02Neutral0.000Benign0.001Benign4.19Benign0.51Tolerated0.14030.3774300.39.01
c.769A>T
S257C
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S257C is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions (premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, Foldetta, Rosetta) and pathogenic predictions (REVEL, polyPhen‑2 HumDiv, polyPhen‑2 HumVar). The high‑accuracy consensus methods—AlphaMissense‑Optimized, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), and Foldetta—each indicate a benign effect. No folding‑stability assessment is available beyond the benign Foldetta result. Overall, the majority of evidence points to a benign impact, and this conclusion is consistent with the absence of a ClinVar assertion. Thus, the variant is most likely benign, and this is not contradicted by ClinVar status, which has no entry for it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.384043Structured0.258293Uncertain0.8470.2720.250-3.553Likely Benign0.189Likely BenignLikely Benign0.50Ambiguous0.4-0.33Likely Benign0.09Likely Benign-0.46Likely Benign0.611Likely Pathogenic0.02Neutral0.999Probably Damaging0.993Probably Damaging5.76Benign0.18Tolerated0.08800.51510-13.316.06
c.1109G>T
G370V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G370V is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster into two groups: benign (REVEL, premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score of Likely Benign) and pathogenic (FoldX, Rosetta, Foldetta, and FATHMM). High‑accuracy assessments further refine this picture: AlphaMissense‑Optimized predicts a benign effect, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign, whereas Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, reports a pathogenic outcome. Overall, the majority of evidence points toward a benign impact, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.461924Structured0.434325Uncertain0.3590.7200.500-5.328Likely Benign0.094Likely BenignLikely Benign4.98Destabilizing3.85.61Destabilizing5.30Destabilizing-0.43Likely Benign0.427Likely Benign0.03Neutral0.000Benign0.000Benign1.32Pathogenic0.29Tolerated0.13060.4198-1-34.642.08
c.2125C>A
L709M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L709M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate benign or likely benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is “Likely Benign,” and Foldetta (combining FoldX‑MD and Rosetta outputs) also predicts benign. No predictions are missing or inconclusive. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.243554Structured0.365830Uncertain0.9340.3790.000-5.242Likely Benign0.108Likely BenignLikely Benign0.18Likely Benign0.00.40Likely Benign0.29Likely Benign-0.10Likely Benign0.065Likely Benign0.03Neutral0.688Possibly Damaging0.235Benign3.41Benign0.17Tolerated0.06290.240942-1.918.03
c.2263A>C
M755L
2D
AIThe SynGAP1 missense variant M755L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is benign, and this conclusion does not contradict any ClinVar annotation (none present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.490133Structured0.783855Binding0.3360.8730.375-1.298Likely Benign0.084Likely BenignLikely Benign0.067Likely Benign0.03Neutral0.000Benign0.001Benign3.39Benign0.22Tolerated0.11670.3311421.9-18.03
c.2263A>T
M755L
2D
AIThe SynGAP1 missense variant M755L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a neutral effect. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign effect, and the SGM‑Consensus (majority vote) yields a likely benign classification. Foldetta results are not available, so they do not influence the assessment. Overall, the computational evidence strongly supports a benign interpretation of M755L, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.490133Structured0.783855Binding0.3360.8730.375-1.298Likely Benign0.084Likely BenignLikely Benign0.067Likely Benign0.03Neutral0.000Benign0.001Benign3.39Benign0.22Tolerated0.11670.3311421.9-18.03
c.2303A>G
D768G
2D
AIThe SynGAP1 D768G missense variant is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in‑silico predictors shows a predominance of benign calls: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Optimized all predict benign, whereas AlphaMissense‑Default predicts pathogenic. The high‑accuracy AlphaMissense‑Optimized result is benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields a benign classification (2 benign vs. 1 pathogenic, with one uncertain). Foldetta, which would provide a protein‑folding stability assessment, has no available output for this variant. Overall, the preponderance of evidence points to a benign effect, and this assessment does not conflict with the absence of a ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.332115Structured0.928237Binding0.3140.8770.250-7.150In-Between0.697Likely PathogenicLikely Benign0.184Likely Benign0.03Neutral0.393Benign0.131Benign4.09Benign0.72Tolerated0.41300.74761-13.1-58.04
c.2504T>C
L835P
2D
AIThe SynGAP1 missense variant L835P is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the overall assessment. Overall, the majority of evidence points to the variant being most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.608892Disordered0.642742Binding0.3190.8630.125-3.024Likely Benign0.139Likely BenignLikely Benign0.144Likely Benign0.03Neutral0.999Probably Damaging0.977Probably Damaging2.78Benign0.04Affected0.34550.1079-3-3-5.4-16.04
c.29G>A
R10Q
2D
AIThe SynGAP1 missense variant R10Q is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33420293‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that R10Q is most likely benign, which does not contradict the current ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.513657Binding0.3300.9150.625Uncertain 26-33420293-G-A201.30e-5-4.438Likely Benign0.185Likely BenignLikely Benign0.084Likely Benign0.03Neutral0.121Benign0.004Benign4.17Benign0.00Affected4.3210.36790.3554111.0-28.06
c.3133G>A
A1045T
2D
AIThe SynGAP1 missense variant A1045T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly supports a benign classification, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975609Disordered0.948874Binding0.3520.8820.750-4.531Likely Benign0.074Likely BenignLikely Benign0.059Likely Benign0.03Neutral0.004Benign0.010Benign2.68Benign0.52Tolerated0.18570.668210-2.530.03
c.313T>C
S105P
2D
AIThe SynGAP1 missense variant S105P is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only two tools—polyPhen‑2 HumDiv and SIFT—predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as likely benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates likely benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence points to a benign effect, which is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.669201Binding0.3640.8700.625Uncertain 1-3.631Likely Benign0.166Likely BenignLikely Benign0.204Likely Benign0.03Neutral0.808Possibly Damaging0.212Benign4.00Benign0.00Affected4.3210.22360.4584-11-0.810.04
c.3937C>A
P1313T
2D
AIThe SynGAP1 missense variant P1313T is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.970301Binding0.4520.9020.750-4.666Likely Benign0.071Likely BenignLikely Benign0.149Likely Benign0.03Neutral0.000Benign0.002Benign4.26Benign0.14Tolerated0.18890.70400-10.93.99
c.3964G>C
A1322P
2D
AIThe SynGAP1 missense variant A1322P is reported in ClinVar (ID 1169945.0) as benign and is present in gnomAD (variant ID 6‑33451838‑G‑C). Across the available in‑silico predictors, all tools uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign predictions. No tool in the dataset indicates a pathogenic effect. High‑accuracy assessments corroborate this consensus: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. The Foldetta protein‑folding stability analysis is not available for this variant. Overall, the computational evidence strongly supports a benign classification, which is consistent with the ClinVar status and does not contradict it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.921040Binding0.4660.8250.875Benign 16-33451838-G-C-1.153Likely Benign0.063Likely BenignLikely Benign0.090Likely Benign0.03Neutral0.000Benign0.000Benign4.15Benign0.23Tolerated3.7750.22550.60941-1-3.426.04
c.2843G>C
G948A
2D
AIThe SynGAP1 missense variant G948A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.862121Binding0.3650.9190.750-5.627Likely Benign0.078Likely BenignLikely Benign0.189Likely Benign0.04Neutral0.288Benign0.103Benign4.64Benign0.39Tolerated0.33500.4957102.214.03
c.2343G>A
M781I
2D
AIThe SynGAP1 missense variant M781I is listed in ClinVar (ID 2802065.0) as Benign and is not reported in gnomAD. All available in‑silico predictors classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the predictions strongly support a benign effect, consistent with the ClinVar designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.580690Disordered0.792850Binding0.3420.8890.625Benign 1-2.484Likely Benign0.323Likely BenignLikely Benign0.101Likely Benign0.05Neutral0.000Benign0.001Benign2.89Benign1.00Tolerated3.6460.14050.2793122.6-18.03
c.2343G>C
M781I
2D
AIThe SynGAP1 missense variant M781I is catalogued in gnomAD (ID 6‑33442895‑G‑C) but has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no reported result for this variant, so its status is unavailable. Overall, the consensus of all available predictions is benign, and this is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.580690Disordered0.792850Binding0.3420.8890.6256-33442895-G-C16.21e-7-2.484Likely Benign0.323Likely BenignLikely Benign0.101Likely Benign0.05Neutral0.000Benign0.001Benign2.89Benign1.00Tolerated3.6460.14050.2793122.6-18.03
c.2343G>T
M781I
2D
AIThe SynGAP1 missense variant M781I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; no tool predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the evidence strongly suggests that M781I is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.580690Disordered0.792850Binding0.3420.8890.625-2.484Likely Benign0.323Likely BenignLikely Benign0.101Likely Benign0.05Neutral0.000Benign0.001Benign2.89Benign1.00Tolerated3.6460.14050.2793122.6-18.03
c.2386C>T
P796S
2D
AIThe SynGAP1 missense variant P796S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) reports likely benign. Foldetta results are not available for this variant. Based on the collective evidence, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.936162Disordered0.426363Uncertain0.4270.9000.875-5.382Likely Benign0.067Likely BenignLikely Benign0.055Likely Benign0.05Neutral0.174Benign0.091Benign4.28Benign0.48Tolerated0.35600.41711-10.8-10.04
c.23T>A
I8N
2D
AIThe SynGAP1 missense variant I8N is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools (polyPhen‑2 HumDiv and SIFT) predict pathogenicity, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the consensus of the majority of predictors, including the high‑accuracy methods, points to a benign impact. This conclusion is consistent with the absence of any ClinVar classification, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.490133Structured0.543080Binding0.3410.9160.625-3.979Likely Benign0.163Likely BenignLikely Benign0.120Likely Benign0.05Neutral0.561Possibly Damaging0.032Benign3.99Benign0.00Affected0.08030.0540-2-3-8.00.94
c.2479A>G
I827V
2D
AIThe SynGAP1 missense variant I827V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). In contrast, the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is also likely benign. No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the majority of evidence indicates that the I827V variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.590140Disordered0.636272Binding0.3830.8840.625-3.590Likely Benign0.249Likely BenignLikely Benign0.129Likely Benign0.05Neutral0.958Probably Damaging0.970Probably Damaging2.70Benign1.00Tolerated0.10110.253643-0.3-14.03
c.2767A>G
I923V
2D
AIThe SynGAP1 missense variant I923V is reported in gnomAD (ID 6‑33443319‑A‑G) and has no ClinVar entry. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate a benign effect. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the consensus of all available predictions is benign, and this is consistent with the absence of a ClinVar pathogenic classification. Therefore, the variant is most likely benign, with no conflict with ClinVar.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.562014Disordered0.964857Binding0.2920.8520.2506-33443319-A-G16.20e-7-2.010Likely Benign0.113Likely BenignLikely Benign0.059Likely Benign0.05Neutral0.028Benign0.009Benign2.76Benign1.00Tolerated3.7750.15890.406034-0.3-14.03
c.3097T>C
S1033P
2D
AIThe SynGAP1 missense variant S1033P is not reported in ClinVar and is absent from gnomAD, indicating no documented population frequency. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are not available, so they do not influence the overall assessment. Based on the consensus of all available predictions, the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.910643Disordered0.993473Binding0.2940.7370.625-2.046Likely Benign0.268Likely BenignLikely Benign0.068Likely Benign0.05Neutral0.002Benign0.005Benign2.68Benign0.27Tolerated0.18890.54861-1-0.810.04
c.3304G>T
A1102S
2D
AIThe SynGAP1 missense variant A1102S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign classification, and this conclusion does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.915074Disordered0.962659Binding0.3880.8590.875-2.900Likely Benign0.067Likely BenignLikely Benign0.041Likely Benign0.05Neutral0.019Benign0.032Benign2.57Benign0.59Tolerated0.26660.650111-2.616.00
c.35G>T
S12I
2D
AIThe SynGAP1 missense variant S12I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and SIFT—suggest a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.490599Uncertain0.3550.9160.500-4.838Likely Benign0.299Likely BenignLikely Benign0.121Likely Benign0.05Neutral0.659Possibly Damaging0.072Benign4.09Benign0.00Affected0.09640.6082-1-25.326.08
c.3757G>T
A1253S
2D
AIThe SynGAP1 missense variant A1253S is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign status. Foldetta results are unavailable. Based on the consensus of all available predictions, the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.661982Disordered0.391377Uncertain0.8810.5500.750-3.639Likely Benign0.090Likely BenignLikely Benign0.041Likely Benign0.05Neutral0.081Benign0.111Benign2.81Benign0.33Tolerated0.20030.415911-2.616.00
c.154T>A
S52T
2D
AIThe SynGAP1 missense variant S52T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumVar and SIFT. The high‑accuracy consensus (SGM‑Consensus, derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. No Foldetta stability result is available. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.291804Structured0.457753Uncertain0.4990.6770.000-5.731Likely Benign0.224Likely BenignLikely Benign0.070Likely Benign0.06Neutral0.140Benign0.481Possibly Damaging4.33Benign0.00Affected0.15050.6751110.114.03
c.16G>T
A6S
2D
AIThe SynGAP1 missense variant A6S is reported in gnomAD (variant ID 6-33420280‑G‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods points to a benign impact. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.566480Disordered0.549054Binding0.3770.9200.8756-33420280-G-T-2.485Likely Benign0.082Likely BenignLikely Benign0.097Likely Benign0.06Neutral0.001Benign0.001Benign4.17Benign0.00Affected4.3210.27200.545711-2.616.00
c.205A>G
I69V
2D
AIThe SynGAP1 missense variant I69V is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic call comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” status. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates benign; Foldetta results are not available. Overall, the consensus of the available predictions indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.575842Disordered0.466129Uncertain0.4370.7860.375-2.809Likely Benign0.176Likely BenignLikely Benign0.080Likely Benign0.06Neutral0.267Benign0.141Benign4.24Benign0.00Affected0.09720.314243-0.3-14.03
c.3097T>G
S1033A
2D
AIThe SynGAP1 missense variant S1033A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable. Overall, the consensus of all available predictions indicates that the variant is most likely benign, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.910643Disordered0.993473Binding0.2940.7370.625-3.107Likely Benign0.121Likely BenignLikely Benign0.033Likely Benign0.06Neutral0.220Benign0.085Benign2.81Benign1.00Tolerated0.43870.5282112.6-16.00
c.3343A>G
I1115V
2D
AIThe SynGAP1 missense variant I1115V is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.892339Binding0.3080.9120.750-2.512Likely Benign0.060Likely BenignLikely Benign0.104Likely Benign0.06Neutral0.002Benign0.007Benign2.76Benign0.68Tolerated0.15610.387143-0.3-14.03
c.3397A>G
I1133V
2D
AIThe SynGAP1 missense variant I1133V is listed in ClinVar as Benign (ClinVar ID 999690.0) and is present in the gnomAD database (gnomAD ID 6‑33443949‑A‑G). All evaluated in‑silico predictors classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is Likely Benign. Foldetta results are unavailable. Consequently, the variant is most likely benign, and this prediction aligns with its ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.832785Binding0.3160.8920.750Benign 16-33443949-A-G221.48e-5-3.362Likely Benign0.067Likely BenignLikely Benign0.180Likely Benign0.06Neutral0.007Benign0.007Benign5.47Benign0.58Tolerated4.3230.11900.398543-0.3-14.0310.1016/j.ajhg.2020.11.011
c.3847C>T
P1283S
2D
AIThe SynGAP1 missense variant P1283S is catalogued in gnomAD (ID 6‑33447895‑C‑T) but has no ClinVar entry. Across a broad panel of in silico predictors, every tool reports a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool in the set predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized returns a benign prediction, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, was not available for this variant. Overall, the computational evidence overwhelmingly supports a benign effect, and this is consistent with the absence of a ClinVar pathogenic classification. Therefore, the variant is most likely benign, and this assessment does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.762850Disordered0.819686Binding0.4840.7320.8756-33447895-C-T-4.289Likely Benign0.072Likely BenignLikely Benign0.040Likely Benign0.06Neutral0.292Benign0.110Benign2.86Benign0.30Tolerated3.7750.28370.3719-110.8-10.04
c.3854C>T
P1285L
2D
AIThe SynGAP1 missense variant P1285L is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign classification for P1285L, and this conclusion is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.821643Binding0.5570.7590.750-3.663Likely Benign0.091Likely BenignLikely Benign0.072Likely Benign0.06Neutral0.072Benign0.029Benign4.31Benign1.00Tolerated0.21590.4539-3-35.416.04
c.65G>T
R22I
2D
AIThe SynGAP1 missense variant R22I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the balance of evidence favors a benign interpretation, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.538167Disordered0.441505Uncertain0.3770.8910.500-4.849Likely Benign0.692Likely PathogenicLikely Benign0.118Likely Benign0.06Neutral0.676Possibly Damaging0.308Benign4.20Benign0.00Affected0.21200.5048-2-39.0-43.03
c.2542G>A
G848S
2D
AIThe SynGAP1 missense variant G848S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). In contrast, the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is also likely benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence indicates that G848S is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.563942Binding0.2870.8160.500-4.077Likely Benign0.104Likely BenignLikely Benign0.134Likely Benign0.07Neutral0.856Possibly Damaging0.476Possibly Damaging2.62Benign0.11Tolerated0.28090.473410-0.430.03
c.357G>C
E119D
2D
AIThe SynGAP1 missense variant E119D is not reported in ClinVar and is absent from gnomAD. All evaluated in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. No tool predicts pathogenicity. The high‑accuracy consensus methods likewise support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.690604Disordered0.661946Binding0.3460.8810.750-3.258Likely Benign0.108Likely BenignLikely Benign0.033Likely Benign0.07Neutral0.000Benign0.001Benign4.08Benign0.32Tolerated3.6150.21800.5759230.0-14.0310.1016/j.ajhg.2020.11.011
c.357G>T
E119D
2D
AIThe SynGAP1 missense variant E119D is reported in gnomAD (variant ID 6‑33432222‑G‑T) but has no ClinVar entry. All available in silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments concur: AlphaMissense‑Optimized indicates a benign effect, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the evidence strongly supports a benign classification, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.690604Disordered0.661946Binding0.3460.8810.7506-33432222-G-T31.86e-6-3.258Likely Benign0.108Likely BenignLikely Benign0.033Likely Benign0.07Neutral0.000Benign0.001Benign4.08Benign0.32Tolerated3.6150.21800.5759230.0-14.0310.1016/j.ajhg.2020.11.011
c.358G>A
G120S
2D
AIThe SynGAP1 missense variant G120S is reported in gnomAD (variant ID 6-33432223‑G‑A) but has no ClinVar entry. Functional prediction tools uniformly classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability predictor, was not available for this variant. Overall, the evidence strongly supports a benign classification, and there is no conflict with ClinVar status because no ClinVar assertion exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.659993Binding0.3590.8870.7506-33432223-G-A16.20e-7-3.558Likely Benign0.082Likely BenignLikely Benign0.034Likely Benign0.07Neutral0.020Benign0.012Benign4.29Benign0.91Tolerated3.6150.28410.471301-0.430.03
c.37A>C
I13L
2D
AIThe SynGAP1 missense variant I13L is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta results are not available, so they do not influence the assessment. Overall, the majority of evidence points to a benign impact, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.486429Structured0.482657Uncertain0.3180.9160.375-2.144Likely Benign0.100Likely BenignLikely Benign0.095Likely Benign0.07Neutral0.002Benign0.001Benign4.19Benign0.00Affected0.10550.492322-0.70.00
c.22A>C
I8L
2D
AIThe SynGAP1 missense variant I8L is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote from the four high‑accuracy tools) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that the I8L variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.490133Structured0.543080Binding0.3410.9160.625-1.752Likely Benign0.083Likely BenignLikely Benign0.124Likely Benign0.08Neutral0.002Benign0.000Benign4.20Benign0.00Affected0.07070.377622-0.70.00
c.2590G>T
A864S
2D
AIThe SynGAP1 missense variant A864S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly supports a benign classification, and there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.549308Disordered0.611966Binding0.2690.7880.250-3.169Likely Benign0.068Likely BenignLikely Benign0.035Likely Benign0.08Neutral0.112Benign0.039Benign2.50Benign0.16Tolerated0.27920.619611-2.616.00
c.2717T>C
L906P
2D
AIThe SynGAP1 missense variant L906P is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors a benign outcome. Foldetta, which would provide a protein‑folding stability estimate, is unavailable for this variant. Overall, the preponderance of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, which contains no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.604312Disordered0.644316Binding0.3150.9200.250-3.662Likely Benign0.478AmbiguousLikely Benign0.150Likely Benign0.08Neutral1.000Probably Damaging0.993Probably Damaging2.18Pathogenic0.10Tolerated0.34300.1458-3-3-5.4-16.04
c.2732T>C
V911A
2D
AIThe SynGAP1 missense variant V911A is not reported in ClinVar and is absent from gnomAD. All evaluated in silico predictors classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta results are unavailable. Based on the consensus of all predictions, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.685117Disordered0.724137Binding0.3270.9140.375-3.030Likely Benign0.249Likely BenignLikely Benign0.118Likely Benign0.08Neutral0.264Benign0.102Benign2.77Benign0.41Tolerated0.30690.333600-2.4-28.05
c.2840G>A
G947E
2D
AIThe SynGAP1 missense variant G947E is reported in ClinVar as “Not submitted” and is present in gnomAD (variant ID 6-33443392-G-A). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome, creating a single discordant signal. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that G947E is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988695Disordered0.850554Binding0.3580.9190.7506-33443392-G-A16.20e-7-9.574Likely Pathogenic0.243Likely BenignLikely Benign0.302Likely Benign0.08Neutral0.126Benign0.096Benign4.92Benign0.10Tolerated4.3240.15550.4259-20-3.172.06
c.7A>T
R3W
2D
AIThe SynGAP1 missense variant R3W is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also resolves to benign. Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for R3W, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.538167Disordered0.550331Binding0.3580.9200.875-5.023Likely Benign0.591Likely PathogenicLikely Benign0.122Likely Benign0.08Neutral0.962Probably Damaging0.363Benign3.94Benign0.00Affected0.14070.46342-33.630.03
c.2695A>G
I899V
2D
AIThe SynGAP1 missense variant I899V is listed in ClinVar as a benign alteration (ClinVar ID 1003653.0) and is present in the gnomAD database (gnomAD ID 6‑33443247‑A‑G). All evaluated in‑silico predictors classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity, so the pathogenic‑prediction group is empty. High‑accuracy assessments further support a benign effect: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the computational evidence strongly suggests the variant is benign, consistent with its ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.443727Uncertain0.2920.9280.375Benign 16-33443247-A-G63.72e-6-2.569Likely Benign0.074Likely BenignLikely Benign0.040Likely Benign0.09Neutral0.220Benign0.078Benign2.75Benign0.92Tolerated4.3240.11690.286443-0.3-14.03
c.2704G>C
A902P
2D
AIThe SynGAP1 missense variant A902P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for A902P, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.517703Binding0.3190.9190.375-4.509Likely Benign0.154Likely BenignLikely Benign0.146Likely Benign0.09Neutral0.995Probably Damaging0.846Possibly Damaging2.56Benign0.01Affected0.16940.53041-1-3.426.04
c.29G>T
R10L
2D
AIThe SynGAP1 missense variant R10L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta results are not available for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.513657Binding0.3300.9150.625-3.269Likely Benign0.244Likely BenignLikely Benign0.143Likely Benign0.09Neutral0.058Benign0.009Benign4.21Benign0.00Affected0.22550.5261-3-28.3-43.03
c.3167G>A
G1056D
2D
AIThe SynGAP1 missense variant G1056D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, ESM1b, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (2 benign vs. 2 pathogenic), and Foldetta results are unavailable. Overall, the majority of evidence (six benign vs. three pathogenic) supports a benign classification. This conclusion does not contradict ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988291Disordered0.868632Binding0.4020.9350.875-10.352Likely Pathogenic0.328Likely BenignLikely Benign0.380Likely Benign0.09Neutral0.666Possibly Damaging0.193Benign1.83Pathogenic0.92Tolerated0.19120.26261-1-3.158.04
c.32G>A
G11E
2D
AIThe SynGAP1 missense variant G11E is reported in gnomAD (variant ID 6-33420296‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus itself is likely benign. Foldetta results are not available, so they do not influence the assessment. Overall, the preponderance of evidence points to a benign variant, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.444081Structured0.501027Binding0.3480.9150.3756-33420296-G-A53.24e-6-4.206Likely Benign0.219Likely BenignLikely Benign0.109Likely Benign0.09Neutral0.000Benign0.000Benign3.95Benign0.00Affected4.3210.14440.4628-20-3.172.06
c.55G>C
A19P
2D
AIThe SynGAP1 missense variant A19P is reported in gnomAD (variant ID 6‑33420319‑G‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the consensus of the available predictions points to a benign impact, and this is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.529623Disordered0.443393Uncertain0.3780.9060.5006-33420319-G-C-3.579Likely Benign0.184Likely BenignLikely Benign0.033Likely Benign0.09Neutral0.001Benign0.000Benign4.07Benign0.00Affected4.3210.26090.6018-11-3.426.04
c.596A>G
N199S
2D
AIThe SynGAP1 missense variant N199S is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). All available in‑silico predictors classify the variant as benign: REVEL, FoldX, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). No tool predicts pathogenicity. High‑accuracy assessments are consistent: AlphaMissense‑Optimized predicts benign; the SGM‑Consensus (majority vote) indicates likely benign; Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also predicts benign. Overall, the variant is most likely benign, and this prediction does not contradict the ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.390993Structured0.431347Uncertain0.5710.4730.125-0.268Likely Benign0.079Likely BenignLikely Benign0.08Likely Benign0.4-0.08Likely Benign0.00Likely Benign-0.44Likely Benign0.040Likely Benign0.09Neutral0.160Benign0.045Benign4.36Benign0.57Tolerated0.26010.6023112.7-27.03
c.82T>G
S28A
2D
AIThe SynGAP1 missense variant S28A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.545602Disordered0.438157Uncertain0.3540.8840.125-3.517Likely Benign0.063Likely BenignLikely Benign0.039Likely Benign0.09Neutral0.000Benign0.000Benign4.27Benign1.00Tolerated0.51940.4958Weaken112.6-16.00
c.2299A>G
I767V
2D
AIThe SynGAP1 missense variant I767V is listed in ClinVar (ID 1402700.0) with an “Uncertain” clinical significance and is not reported in gnomAD. All evaluated in‑silico predictors classify the substitution as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a “Likely Benign” outcome. No tool predicts pathogenicity. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, while Foldetta (combining FoldX‑MD and Rosetta stability predictions) has no available result for this variant. Overall, the computational evidence strongly supports a benign effect, and this conclusion does not contradict the current ClinVar status of uncertainty.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.321458Structured0.927771Binding0.3690.8720.125Uncertain 1-2.791Likely Benign0.064Likely BenignLikely Benign0.096Likely Benign0.10Neutral0.072Benign0.029Benign4.21Benign1.00Tolerated3.6460.14180.422743-0.3-14.03
c.2591C>A
A864E
2D
AIThe SynGAP1 missense variant A864E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors a benign outcome. Foldetta, which evaluates protein‑folding stability, has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing clinical database.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.549308Disordered0.611966Binding0.2690.7880.250-5.508Likely Benign0.350AmbiguousLikely Benign0.153Likely Benign0.10Neutral0.138Benign0.070Benign2.45Pathogenic0.04Affected0.12040.20370-1-5.358.04
c.2821C>G
P941A
2D
AIThe SynGAP1 missense variant P941A is reported in gnomAD (variant ID 6-33443373-C-G) but has no ClinVar entry. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate a benign effect. No tool predicts pathogenicity. The high‑accuracy consensus, SGM‑Consensus, also reports the variant as Likely Benign, and AlphaMissense‑Optimized concurs with a benign prediction. Foldetta, a protein‑folding stability method, did not provide a result for this variant, so its status remains unavailable. Overall, the collective evidence strongly supports a benign classification, and this assessment is consistent with the absence of a ClinVar pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.874069Disordered0.900790Binding0.4030.9060.6256-33443373-C-G21.24e-6-4.313Likely Benign0.054Likely BenignLikely Benign0.046Likely Benign0.10Neutral0.000Benign0.002Benign2.80Benign0.10Tolerated4.3240.28440.5190-113.4-26.04
c.2828G>C
G943A
2D
AIThe SynGAP1 missense variant G943A is reported in gnomAD (ID 6‑33443380‑G‑C) but has no ClinVar entry. All available in silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Based on the unanimous benign predictions and lack of ClinVar pathogenicity, the variant is most likely benign and does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.973328Disordered0.860437Binding0.3720.9100.7506-33443380-G-C31.86e-6-6.684Likely Benign0.070Likely BenignLikely Benign0.274Likely Benign0.10Neutral0.001Benign0.002Benign2.87Benign0.89Tolerated4.3240.34150.4957012.214.03
c.3151G>A
G1051S
2D
AIThe SynGAP1 missense variant G1051S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only FATHMM predicts a pathogenic outcome. When the predictions are grouped, the benign consensus includes eight tools, whereas the pathogenic consensus contains a single tool. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports a benign effect, and the SGM‑Consensus—derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also indicates a likely benign outcome. Foldetta data are unavailable, so no stability inference can be drawn. Overall, the computational evidence overwhelmingly supports a benign classification for G1051S, and this conclusion is consistent with the absence of any ClinVar annotation. Thus, the variant is most likely benign, and this assessment does not contradict ClinVar status, which is currently unreported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.900141Binding0.3580.9360.875-4.742Likely Benign0.079Likely BenignLikely Benign0.445Likely Benign0.10Neutral0.245Benign0.096Benign-0.74Pathogenic0.61Tolerated0.24460.491110-0.430.03
c.3355G>A
G1119R
2D
AIThe SynGAP1 missense variant G1119R is listed in ClinVar as benign and is present in gnomAD (ID 6‑33443907‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and ESM1b predict a pathogenic impact. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, aligning with the ClinVar classification; there is no contradiction between the predictions and the reported ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.827927Disordered0.818538Binding0.3390.9280.875Benign 16-33443907-G-A644.23e-5-8.489Likely Pathogenic0.473AmbiguousLikely Benign0.303Likely Benign0.10Neutral0.969Probably Damaging0.462Possibly Damaging4.03Benign0.10Tolerated4.3220.11120.4733-3-2-4.199.14
c.3355G>C
G1119R
2D
AIThe SynGAP1 missense variant G1119R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. AlphaMissense‑Default is uncertain. High‑accuracy assessment shows AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also resolves to benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence points to a benign effect. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.827927Disordered0.818538Binding0.3390.9280.875-8.489Likely Pathogenic0.473AmbiguousLikely Benign0.289Likely Benign0.10Neutral0.969Probably Damaging0.462Possibly Damaging4.03Benign0.10Tolerated4.3220.11120.4733-3-2-4.199.14
c.3974C>A
P1325H
2D
AIThe SynGAP1 missense variant P1325H is reported in gnomAD (variant ID 6‑33451848‑C‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; pathogenic predictions come from polyPhen‑2 HumDiv and SIFT. The high‑accuracy consensus methods reinforce the benign assessment: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” No result is available from the Foldetta stability analysis. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.893621Binding0.4390.7910.8756-33451848-C-A-6.970Likely Benign0.136Likely BenignLikely Benign0.056Likely Benign0.10Neutral0.704Possibly Damaging0.187Benign4.04Benign0.00Affected4.3210.21030.4364-20-1.640.02
c.239A>G
K80R
2D
AIThe SynGAP1 missense variant K80R is reported in gnomAD (ID 6‑33425847‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.637480Disordered0.477530Uncertain0.3310.8730.5006-33425847-A-G16.20e-7-2.919Likely Benign0.146Likely BenignLikely Benign0.077Likely Benign0.11Neutral0.001Benign0.001Benign4.33Benign0.00Affected4.3210.44810.085823-0.628.01
c.346T>C
Y116H
2D
AIThe SynGAP1 missense variant Y116H is listed in gnomAD (ID 6‑33432211‑T‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all indicate benign or likely benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments confirm the benign trend: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus also reports it as likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status, as none is currently assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.661982Disordered0.670235Binding0.3810.8780.6256-33432211-T-C74.34e-6-1.512Likely Benign0.378AmbiguousLikely Benign0.080Likely Benign0.11Neutral0.539Possibly Damaging0.085Benign4.21Benign0.40Tolerated3.6150.26910.048520-1.9-26.03
c.3940C>T
P1314S
2D
AIThe SynGAP1 missense variant P1314S has no ClinVar entry and is not reported in gnomAD. All evaluated in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports a benign effect, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the computational evidence strongly supports a benign classification, and this is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.971592Binding0.4670.9030.750-3.838Likely Benign0.081Likely BenignLikely Benign0.046Likely Benign0.11Neutral0.005Benign0.003Benign4.22Benign0.72Tolerated0.35220.47511-10.8-10.04
c.43G>T
A15S
2D
AIThe SynGAP1 missense variant A15S is reported in ClinVar as “Not submitted” and is present in gnomAD (variant ID 6-33420307‑G‑T). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign status. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign effect for A15S, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.436924Structured0.466055Uncertain0.3300.9120.3756-33420307-G-T-2.925Likely Benign0.084Likely BenignLikely Benign0.074Likely Benign0.11Neutral0.122Benign0.010Benign4.17Benign0.00Affected4.3210.31150.583011-2.616.00
c.955G>C
A319P
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A319P is catalogued in gnomAD (ID 6‑33437860‑G‑C) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. Predictions that are inconclusive are Rosetta, ESM1b, and Foldetta. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also resolves to benign, while Foldetta remains uncertain. Overall, the majority of evidence points to a benign effect, and this is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.179055Structured0.410405Uncertain0.8790.2540.1256-33437860-G-C31.86e-6-7.213In-Between0.109Likely BenignLikely Benign-0.02Likely Benign0.9-1.18Ambiguous-0.60Ambiguous0.22Likely Benign0.286Likely Benign0.11Neutral0.999Probably Damaging0.977Probably Damaging1.97Pathogenic1.00Tolerated3.38230.18390.5067-11-3.426.04
c.1099C>A
L367M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 L367M variant is not reported in ClinVar and is absent from gnomAD. Prediction tools that uniformly indicate a benign effect include REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv and FATHMM. The remaining predictions are uncertain: Rosetta and Foldetta. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is also likely benign; Foldetta remains inconclusive. Overall, the majority of evidence supports a benign classification, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.370445Structured0.441805Uncertain0.7900.6570.250-4.968Likely Benign0.111Likely BenignLikely Benign0.22Likely Benign0.10.92Ambiguous0.57Ambiguous-0.04Likely Benign0.078Likely Benign0.12Neutral0.947Possibly Damaging0.360Benign1.63Pathogenic0.13Tolerated0.14020.394742-1.918.03
c.190A>G
I64V
2D
AIThe SynGAP1 missense variant I64V is reported as “Likely Benign” in ClinVar and is not listed in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence supports a benign classification, and this is consistent with the ClinVar status (no conflicting pathogenic annotation).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.422041Structured0.475481Uncertain0.4780.7470.125-2.616Likely Benign0.154Likely BenignLikely Benign0.086Likely Benign0.12Neutral0.000Benign0.000Benign4.24Benign0.00Affected0.09940.330243-0.3-14.03
c.304T>A
L102M
2D
AIThe SynGAP1 missense variant L102M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for the variant, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.696014Binding0.3570.8850.625-5.033Likely Benign0.085Likely BenignLikely Benign0.129Likely Benign0.12Neutral0.984Probably Damaging0.969Probably Damaging4.14Benign0.00Affected0.10910.417642-1.918.03
c.3166G>C
G1056R
2D
AIThe SynGAP1 missense variant G1056R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are ESM1b and FATHMM, while AlphaMissense‑Default remains uncertain. High‑accuracy assessment shows AlphaMissense‑Optimized as benign, the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) favors a pathogenic outcome, and Foldetta data are unavailable. Overall, the majority of conventional predictors indicate a benign impact, whereas the SGM Consensus suggests pathogenicity. Given the preponderance of benign predictions and the lack of ClinVar evidence, the variant is most likely benign, and this assessment does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988291Disordered0.868632Binding0.4020.9350.875-9.358Likely Pathogenic0.390AmbiguousLikely Benign0.410Likely Benign0.12Neutral0.011Benign0.010Benign1.83Pathogenic0.13Tolerated0.11270.4533-3-2-4.199.14
c.385T>A
S129T
2D
AIThe SynGAP1 missense variant S129T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.517562Disordered0.713635Binding0.3110.8800.625-4.296Likely Benign0.171Likely BenignLikely Benign0.134Likely Benign0.12Neutral0.016Benign0.021Benign4.14Benign0.85Tolerated0.12510.5794110.114.03
c.41C>G
P14R
2D
AIThe SynGAP1 missense variant P14R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The high‑accuracy consensus methods give a benign verdict: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” No result is available from Foldetta, so its folding‑stability assessment is not considered. Overall, the majority of evidence points to a benign impact, and this is consistent with the lack of any ClinVar classification. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.433034Structured0.471596Uncertain0.3990.9090.375-2.794Likely Benign0.253Likely BenignLikely Benign0.183Likely Benign0.13Neutral0.486Possibly Damaging0.032Benign4.20Benign0.00Affected0.15970.35360-2-2.959.07
c.151A>C
I51L
2D
AIThe SynGAP1 missense variant I51L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the consensus of the majority of tools and the high‑accuracy predictions point to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.291804Structured0.454181Uncertain0.6060.7100.0000.408Likely Benign0.147Likely BenignLikely Benign0.080Likely Benign0.14Neutral0.000Benign0.001Benign4.35Benign0.00Affected0.09240.399322-0.70.00
c.2392C>T
P798S
2D
AIThe SynGAP1 missense variant P798S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and SIFT—suggest a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta results are not available, so they do not influence the assessment. Overall, the majority of evidence points to a benign effect, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.871313Disordered0.492709Uncertain0.4260.8990.875-5.382Likely Benign0.065Likely BenignLikely Benign0.058Likely Benign0.14Neutral0.818Possibly Damaging0.353Benign4.28Benign0.00Affected0.29500.44251-10.8-10.04
c.2420A>T
Y807F
2D
AIThe SynGAP1 missense variant Y807F is listed in ClinVar (ID 1491782.0) with an “Uncertain” status and is not reported in gnomAD. All evaluated in‑silico predictors classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign effect. No tool in the set predicts pathogenicity. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (derived from the four high‑accuracy predictors) is benign. Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, has no available result for this variant. Overall, the computational evidence strongly supports a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.699094Disordered0.853760Binding0.3360.9010.500Uncertain 1-3.667Likely Benign0.073Likely BenignLikely Benign0.057Likely Benign0.14Neutral0.012Benign0.022Benign2.92Benign0.98Tolerated3.7750.24850.2500734.1-16.00
c.2557G>A
G853S
2D
AIThe SynGAP1 missense variant G853S is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that G853S is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.657645Disordered0.496246Uncertain0.2840.8150.625-3.878Likely Benign0.067Likely BenignLikely Benign0.155Likely Benign0.14Neutral0.003Benign0.008Benign4.31Benign0.02Affected0.27830.520610-0.430.03
c.2753C>G
A918G
2D
AIThe SynGAP1 missense variant A918G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic outcome. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are not available for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.632174Disordered0.891459Binding0.3170.8600.250-2.906Likely Benign0.081Likely BenignLikely Benign0.099Likely Benign0.14Neutral0.954Possibly Damaging0.630Possibly Damaging2.72Benign0.70Tolerated0.21250.437610-2.2-14.03
c.2918G>C
G973A
2D
AIThe SynGAP1 missense variant G973A is reported in gnomAD (ID 6‑33443470‑G‑C) but has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. The high‑accuracy consensus (SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly supports a benign classification, and this assessment is consistent with the absence of a ClinVar pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.959498Binding0.3900.8970.6256-33443470-G-C16.20e-7-3.847Likely Benign0.075Likely BenignLikely Benign0.091Likely Benign0.14Neutral0.112Benign0.028Benign4.30Benign0.62Tolerated4.3220.34050.5133012.214.03
c.3445C>T
P1149S
2D
AIThe SynGAP1 missense variant P1149S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.762850Disordered0.786938Binding0.4240.8370.625-2.650Likely Benign0.184Likely BenignLikely Benign0.067Likely Benign0.14Neutral0.068Benign0.065Benign3.18Benign0.48Tolerated0.34600.48261-10.8-10.04
c.3598G>C
E1200Q
2D
AIThe SynGAP1 missense variant E1200Q is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available, so these do not influence the overall interpretation. High‑accuracy assessments—AlphaMissense‑Optimized (benign) and SGM‑Consensus (likely benign)—support a benign classification. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.545602Disordered0.458056Uncertain0.8890.5960.250-4.411Likely Benign0.464AmbiguousLikely Benign0.183Likely Benign0.14Neutral0.994Probably Damaging0.946Probably Damaging2.84Benign0.30Tolerated0.07670.4012220.0-0.98
c.2843G>A
G948D
2D
AIThe SynGAP1 missense variant G948D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.862121Binding0.3650.9190.750-8.423Likely Pathogenic0.267Likely BenignLikely Benign0.279Likely Benign0.15Neutral0.818Possibly Damaging0.266Benign4.55Benign0.11Tolerated0.18710.28261-1-3.158.04
c.3164G>C
G1055A
2D
AIThe SynGAP1 missense variant G1055A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only polyPhen‑2 HumDiv indicates a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign and the SGM‑Consensus also reports Likely Benign; Foldetta results are unavailable. Overall, the consensus of the available predictions points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.872113Binding0.3790.9350.875-6.835Likely Benign0.083Likely BenignLikely Benign0.244Likely Benign0.15Neutral0.649Possibly Damaging0.148Benign3.30Benign1.00Tolerated0.33500.5144102.214.03
c.3334G>A
E1112K
2D
AIThe SynGAP1 missense variant E1112K is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools largely agree on a benign effect: SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict benign. Only two tools predict pathogenicity: SIFT and AlphaMissense‑Default. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the conclusion. Overall, the majority of predictions, including the high‑accuracy tools, suggest the variant is most likely benign, and this is consistent with the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.894241Disordered0.909381Binding0.3350.9020.875-3.772Likely Benign0.684Likely PathogenicLikely Benign0.210Likely Benign0.15Neutral0.245Benign0.096Benign2.82Benign0.02Affected0.30020.770401-0.4-0.94
c.61T>C
F21L
2D
AIThe SynGAP1 missense variant F21L is reported in gnomAD (ID 6‑33420325‑T‑C) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized uncertain, SGM‑Consensus Likely Benign, and no Foldetta stability data is available. Overall, the balance of evidence favors a benign classification, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.443284Uncertain0.3690.8970.5006-33420325-T-C-2.480Likely Benign0.940Likely PathogenicAmbiguous0.140Likely Benign0.15Neutral0.140Benign0.153Benign4.34Benign0.00Affected4.3210.26800.3250021.0-34.02
c.63C>A
F21L
2D
AIThe SynGAP1 missense variant F21L is reported in gnomAD (ID 6‑33420327‑C‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, SGM‑Consensus as Likely Benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.443284Uncertain0.3690.8970.5006-33420327-C-A-2.480Likely Benign0.940Likely PathogenicAmbiguous0.103Likely Benign0.15Neutral0.140Benign0.153Benign4.34Benign0.00Affected4.3210.26800.3250021.0-34.02
c.63C>G
F21L
2D
AIThe SynGAP1 missense variant F21L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain, and no Foldetta stability assessment is available. The high‑accuracy consensus (SGM‑Consensus) classifies the variant as Likely Benign, while AlphaMissense‑Optimized remains uncertain and Foldetta is unavailable. Overall, the majority of evidence points to a benign impact. The predictions do not contradict the ClinVar status, which is currently unreported. Thus, based on the available computational predictions, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.443284Uncertain0.3690.8970.500-2.480Likely Benign0.940Likely PathogenicAmbiguous0.104Likely Benign0.15Neutral0.140Benign0.153Benign4.34Benign0.00Affected4.3210.26800.3250021.0-34.02
c.2327G>A
G776D
2D
AIThe SynGAP1 missense variant G776D is catalogued in gnomAD (ID 6‑33442485‑G‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions come from AlphaMissense‑Default, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is “Likely Benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized scores benign, and the SGM‑Consensus (majority of the four high‑accuracy tools) also indicates benign. Foldetta stability analysis is unavailable, so it does not influence the assessment. Overall, the preponderance of evidence points to a benign effect for G776D, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.377384Structured0.886983Binding0.2960.8880.2506-33442485-G-A0.388Likely Benign0.566Likely PathogenicLikely Benign0.188Likely Benign0.16Neutral0.999Probably Damaging0.996Probably Damaging4.30Benign0.10Tolerated3.6460.18350.2971-11-3.158.04
c.2834A>T
H945L
2D
AIThe SynGAP1 missense variant H945L is reported in gnomAD (ID 6‑33443386‑A‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict the variant to be pathogenic. High‑accuracy assessments reinforce the benign view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this is consistent with the absence of a pathogenic ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.7506-33443386-A-T21.24e-6-4.741Likely Benign0.088Likely BenignLikely Benign0.399Likely Benign0.16Neutral0.948Possibly Damaging0.863Possibly Damaging5.05Benign1.00Tolerated4.3240.20850.4526-3-27.0-23.98
c.3094C>G
L1032V
2D
AIThe SynGAP1 missense variant L1032V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools, polyPhen‑2 HumDiv and polyPhen‑2 HumVar, predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for the variant, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.865454Disordered0.995318Binding0.3650.7350.500-4.123Likely Benign0.176Likely BenignLikely Benign0.075Likely Benign0.16Neutral0.889Possibly Damaging0.514Possibly Damaging2.78Benign0.78Tolerated0.16370.4353210.4-14.03
c.39C>G
I13M
2D
AIThe SynGAP1 missense variant I13M is reported in gnomAD (ID 6‑33420303‑C‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus itself is likely benign. Foldetta results are not available, so they do not influence the assessment. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar status (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.486429Structured0.482657Uncertain0.3180.9160.3756-33420303-C-G16.49e-7-4.097Likely Benign0.170Likely BenignLikely Benign0.093Likely Benign0.16Neutral0.296Benign0.022Benign4.04Benign0.00Affected4.3210.08830.380612-2.618.03
c.4A>T
S2C
2D
AIThe SynGAP1 missense variant S2C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.543646Binding0.3820.9220.750-5.328Likely Benign0.187Likely BenignLikely Benign0.067Likely Benign0.16Neutral0.916Possibly Damaging0.091Benign4.01Benign0.00Affected0.11450.64620-13.316.06
c.973C>G
L325V
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant L325V is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are FoldX, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. Rosetta and Foldetta give uncertain results. The high‑accuracy consensus from AlphaMissense‑Optimized is benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is likely benign, and Foldetta remains uncertain. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.352862Structured0.424577Uncertain0.9550.4360.000-3.104Likely Benign0.162Likely BenignLikely Benign2.26Destabilizing0.11.27Ambiguous1.77Ambiguous-0.39Likely Benign0.183Likely Benign0.16Neutral0.898Possibly Damaging0.472Possibly Damaging1.68Pathogenic1.00Tolerated0.15710.3957210.4-14.03
c.50C>G
S17C
2D
AIThe SynGAP1 missense variant S17C is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools (polyPhen‑2 HumDiv and SIFT) predict pathogenicity, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.483068Structured0.452228Uncertain0.3410.9100.375-4.364Likely Benign0.279Likely BenignLikely Benign0.044Likely Benign0.17Neutral0.486Possibly Damaging0.048Benign3.99Benign0.00Affected0.12260.67210-13.316.06
c.1204C>G
L402V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L402V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, premPS, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign; the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports a benign outcome. Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, yields an uncertain result and is therefore not considered evidence for pathogenicity. In summary, all available predictions support a benign classification for the L402V variant, and this conclusion does not contradict the absence of a ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.243554Structured0.431978Uncertain0.9610.3830.000-3.467Likely Benign0.105Likely BenignLikely Benign1.91Ambiguous0.10.78Ambiguous1.35Ambiguous-0.11Likely Benign0.203Likely Benign0.18Neutral0.004Benign0.004Benign4.01Benign0.29Tolerated0.18070.3657210.4-14.03
c.23T>G
I8S
2D
AIThe SynGAP1 missense variant I8S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments further support a benign prediction: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.490133Structured0.543080Binding0.3410.9160.625-1.577Likely Benign0.122Likely BenignLikely Benign0.266Likely Benign0.18Neutral0.107Benign0.006Benign4.02Benign0.00Affected0.27260.0910-1-2-5.3-26.08
c.3149G>C
G1050A
2D
AIThe SynGAP1 missense variant G1050A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.906802Binding0.3700.9280.875-5.514Likely Benign0.074Likely BenignLikely Benign0.047Likely Benign0.18Neutral0.000Benign0.004Benign2.68Benign1.00Tolerated0.33490.5133102.214.03
c.3925G>A
V1309M
2D
AIThe SynGAP1 missense variant V1309M is listed in ClinVar with no submitted interpretation and is present in gnomAD (variant ID 6-33451799-G-A). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; no Foldetta stability data are available. Overall, the majority of evidence points to a benign impact for V1309M, and this conclusion does not contradict ClinVar status, which currently has no pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.712013Disordered0.948596Binding0.4020.9070.7506-33451799-G-A16.20e-7-4.653Likely Benign0.183Likely BenignLikely Benign0.072Likely Benign0.18Neutral0.651Possibly Damaging0.346Benign2.44Pathogenic0.04Affected3.7750.08200.411612-2.332.06
c.3931C>A
L1311M
2D
AIThe SynGAP1 missense variant L1311M is reported in gnomAD (ID 6‑33451805‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates “Likely Benign.” In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. High‑accuracy assessments reinforce the benign view: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence supports a benign classification for L1311M, and this conclusion is not contradicted by any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.968153Binding0.3930.9070.7506-33451805-C-A31.86e-6-4.817Likely Benign0.099Likely BenignLikely Benign0.060Likely Benign0.18Neutral0.936Possibly Damaging0.632Possibly Damaging2.73Benign0.23Tolerated3.7750.10680.427924-1.918.03
c.1099C>G
L367V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L367V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only FATHMM predicts a pathogenic outcome. Stability‑based methods (FoldX, Rosetta, Foldetta) are inconclusive, so they provide no evidence for or against pathogenicity. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as likely benign, and Foldetta as uncertain. Overall, the preponderance of evidence points to a benign effect for L367V, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.370445Structured0.441805Uncertain0.7900.6570.250-2.383Likely Benign0.066Likely BenignLikely Benign1.48Ambiguous0.21.72Ambiguous1.60Ambiguous0.15Likely Benign0.040Likely Benign0.19Neutral0.410Benign0.104Benign1.67Pathogenic0.13Tolerated0.23210.3285210.4-14.03
c.1402A>C
M468L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M468L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 HumDiv, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumVar and FATHMM. The SGM‑Consensus, which is a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments—all available—show benign predictions: AlphaMissense‑Optimized (Benign), SGM‑Consensus (Likely Benign), and Foldetta (Benign). Based on the overall consensus of the majority of tools and the high‑accuracy predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.284882Structured0.339253Uncertain0.9320.2570.000-6.886Likely Benign0.290Likely BenignLikely Benign0.43Likely Benign0.1-0.38Likely Benign0.03Likely Benign-0.35Likely Benign0.412Likely Benign0.19Neutral0.359Benign0.654Possibly Damaging-0.73Pathogenic1.00Tolerated0.15640.4408421.9-18.03
c.1402A>T
M468L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M468L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 HumDiv, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumVar and FATHMM. The SGM‑Consensus, which is a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments—AlphaMissense‑Optimized, the SGM‑Consensus, and Foldetta (combining FoldX‑MD and Rosetta outputs)—all indicate a benign outcome. No prediction or folding‑stability result is missing or inconclusive. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.284882Structured0.339253Uncertain0.9320.2570.000-6.886Likely Benign0.290Likely BenignLikely Benign0.43Likely Benign0.1-0.38Likely Benign0.03Likely Benign-0.35Likely Benign0.412Likely Benign0.19Neutral0.359Benign0.654Possibly Damaging-0.73Pathogenic1.00Tolerated0.15640.4408421.9-18.03
c.2552C>A
P851H
2D
AIThe SynGAP1 missense variant P851H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.648219Disordered0.526893Binding0.3470.8190.625-4.730Likely Benign0.102Likely BenignLikely Benign0.184Likely Benign0.19Neutral1.000Probably Damaging0.998Probably Damaging4.18Benign0.15Tolerated0.15770.53780-2-1.640.02
c.2821C>A
P941T
2D
AIThe SynGAP1 missense variant P941T is listed in gnomAD (ID 6‑33443373‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status, as none is currently assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.874069Disordered0.900790Binding0.4030.9060.6256-33443373-C-A21.24e-6-6.193Likely Benign0.065Likely BenignLikely Benign0.033Likely Benign0.19Neutral0.144Benign0.085Benign2.77Benign0.05Affected4.3240.16120.5607-100.93.99
c.2854G>A
G952S
2D
AIThe SynGAP1 missense variant G952S is listed in ClinVar (ID 1325573.0) with an “Uncertain” clinical significance and is present in gnomAD (variant ID 6‑33443406‑G‑A). All evaluated in‑silico predictors agree on a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. No tool predicts pathogenicity. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status is unavailable. Overall, the computational evidence strongly supports a benign classification, which is consistent with the ClinVar “Uncertain” status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.910621Binding0.3410.9260.750Conflicting 26-33443406-G-A21.24e-6-6.190Likely Benign0.077Likely BenignLikely Benign0.167Likely Benign0.19Neutral0.000Benign0.002Benign3.31Benign0.07Tolerated3.7750.25090.550210-0.430.03
c.967C>G
L323V
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant L323V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions (REVEL, premPS, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized) and pathogenic predictions (FoldX, Rosetta, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM). The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is labeled Likely Benign. High‑accuracy assessments further refine the picture: AlphaMissense‑Optimized predicts benign; the SGM‑Consensus (majority of the four high‑accuracy tools) also indicates Likely Benign; Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, predicts pathogenic. Overall, the majority of evidence points to a benign effect, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.268042Structured0.428564Uncertain0.9560.3690.000-3.483Likely Benign0.107Likely BenignLikely Benign2.18Destabilizing0.32.22Destabilizing2.20Destabilizing0.17Likely Benign0.227Likely Benign0.19Neutral0.898Possibly Damaging0.472Possibly Damaging0.80Pathogenic0.80Tolerated0.12770.2656210.4-14.03
c.1501A>G
I501V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I501V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Predictions from FoldX, Rosetta, and Foldetta are uncertain and are treated as unavailable. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as likely benign, and Foldetta as uncertain. Overall, the majority of evidence points to a benign impact for I501V, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.079919Structured0.366596Uncertain0.8860.1530.000-2.326Likely Benign0.083Likely BenignLikely Benign0.94Ambiguous0.00.56Ambiguous0.75Ambiguous0.06Likely Benign0.200Likely Benign0.20Neutral0.951Possibly Damaging0.960Probably Damaging3.52Benign1.00Tolerated0.09850.249143-0.3-14.03
c.2530C>G
L844V
2D
AIThe SynGAP1 missense variant L844V is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.595080Disordered0.611301Binding0.3040.8350.3750.094Likely Benign0.240Likely BenignLikely Benign0.043Likely Benign0.20Neutral0.409Benign0.253Benign2.87Benign0.62Tolerated0.16920.3744210.4-14.03
c.2593G>T
A865S
2D
AIThe SynGAP1 missense variant A865S is reported as “Likely Benign” in SGM‑Consensus and has no ClinVar entry or gnomAD allele. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool in the dataset predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is also benign. Foldetta results are not available. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.521092Disordered0.626222Binding0.2710.7880.250-3.102Likely Benign0.073Likely BenignLikely Benign0.050Likely Benign0.20Neutral0.009Benign0.019Benign2.78Benign0.52Tolerated0.23140.487611-2.616.00
c.3151G>C
G1051R
2D
AIThe SynGAP1 missense variant G1051R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and FATHMM. Two tools (ESM1b and AlphaMissense‑Default) are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because it contains one pathogenic, one benign, and two uncertain calls, and Foldetta results are unavailable. Overall, the balance of evidence favors a benign classification. This conclusion does not contradict ClinVar status, as the variant has no ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.900141Binding0.3580.9360.875-7.907In-Between0.346AmbiguousLikely Benign0.438Likely Benign0.20Neutral0.761Possibly Damaging0.305Benign-0.74Pathogenic0.20Tolerated0.09560.4342-3-2-4.199.14
c.3185G>C
G1062A
2D
AIThe SynGAP1 missense variant G1062A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is benign, and this conclusion does not contradict any ClinVar annotation (none present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.936972Binding0.3680.9170.875-6.124Likely Benign0.079Likely BenignLikely Benign0.350Likely Benign0.20Neutral0.059Benign0.028Benign4.20Benign0.51Tolerated0.33050.5144102.214.03
c.3187G>A
G1063S
2D
AIThe SynGAP1 missense variant G1063S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign. Foldetta results are unavailable, so they do not influence the overall assessment. Consequently, the variant is most likely benign based on the collective predictions, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975134Disordered0.945784Binding0.3940.9130.875-4.707Likely Benign0.067Likely BenignLikely Benign0.052Likely Benign0.20Neutral0.004Benign0.003Benign4.33Benign0.09Tolerated0.24910.570210-0.430.03
c.3758C>T
A1253V
2D
AIThe SynGAP1 missense variant A1253V is predicted to be benign by every evaluated in‑silico tool. Benign predictions are reported by REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments confirm this: AlphaMissense‑Optimized classifies the variant as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. ClinVar contains no entry for A1253V, and the variant is absent from gnomAD. Based on the unanimous benign predictions and lack of conflicting evidence, the variant is most likely benign, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.661982Disordered0.391377Uncertain0.8810.5500.750-4.706Likely Benign0.060Likely BenignLikely Benign0.057Likely Benign0.20Neutral0.000Benign0.001Benign2.85Benign1.00Tolerated0.07840.4473002.428.05
c.38T>G
I13S
2D
AIThe SynGAP1 missense variant I13S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus methods also support a benign classification: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for I13S, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.486429Structured0.482657Uncertain0.3180.9160.375-1.756Likely Benign0.187Likely BenignLikely Benign0.264Likely Benign0.20Neutral0.024Benign0.002Benign4.06Benign0.00Affected0.32920.1682-1-2-5.3-26.08
c.3913A>T
T1305S
2D
AIThe SynGAP1 missense variant T1305S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on current predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.791621Disordered0.894658Binding0.3900.8730.875-2.813Likely Benign0.074Likely BenignLikely Benign0.053Likely Benign0.20Neutral0.003Benign0.026Benign2.83Benign0.08Tolerated0.36830.498811-0.1-14.03
c.3919C>A
P1307T
2D
AIThe SynGAP1 missense variant P1307T is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset predicts pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, is not available for this variant. Overall, the consensus of all available predictions strongly suggests that P1307T is most likely benign, and this conclusion is consistent with the lack of ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.798249Disordered0.913511Binding0.4910.9010.875-4.262Likely Benign0.093Likely BenignLikely Benign0.072Likely Benign0.20Neutral0.386Benign0.266Benign3.07Benign0.60Tolerated0.17320.54360-10.93.99
c.44C>T
A15V
2D
AIThe SynGAP1 missense variant A15V is listed in ClinVar (ID 1801174.0) with an “Uncertain” status and is present in gnomAD (6‑33420308‑C‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized, while polyPhen‑2 HumDiv and SIFT predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this does not contradict the ClinVar designation, which remains uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.436924Structured0.466055Uncertain0.3300.9120.375Uncertain 16-33420308-C-T16.49e-7-3.560Likely Benign0.161Likely BenignLikely Benign0.105Likely Benign0.20Neutral0.602Possibly Damaging0.015Benign4.19Benign0.00Affected4.3210.18090.7669002.428.05
c.783C>A
D261E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant D261E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The high‑accuracy consensus from AlphaMissense‑Optimized and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) both indicate a benign outcome, while Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, is inconclusive. Overall, the majority of evidence points to a benign impact. This assessment is consistent with the absence of ClinVar annotation and does not contradict any existing database status. Based on the predictions, the variant is most likely benign, and this does not contradict the ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.284882Structured0.422514Uncertain0.8830.2640.125-2.646Likely Benign0.268Likely BenignLikely Benign1.44Ambiguous0.80.79Ambiguous1.12Ambiguous-0.03Likely Benign0.377Likely Benign0.20Neutral0.994Probably Damaging0.978Probably Damaging5.88Benign1.00Tolerated0.09630.4359320.014.03
c.783C>G
D261E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant D261E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) is inconclusive. Protein‑stability calculations from FoldX and Rosetta are uncertain. Overall, the majority of evidence points to a benign impact, which is consistent with the absence of a ClinVar claim and gnomAD observation. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.284882Structured0.422514Uncertain0.8830.2640.125-2.646Likely Benign0.268Likely BenignLikely Benign1.44Ambiguous0.80.79Ambiguous1.12Ambiguous-0.03Likely Benign0.377Likely Benign0.20Neutral0.994Probably Damaging0.978Probably Damaging5.88Benign1.00Tolerated0.09630.4359320.014.03
c.964G>A
A322T
2D
AIThe SynGAP1 missense variant A322T is not reported in ClinVar and is absent from gnomAD. Consensus from most in silico predictors classifies the change as benign: SGM‑Consensus (Likely Benign), REVEL, Rosetta, Foldetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a neutral effect. Only FATHMM indicates a pathogenic signal, while FoldX and premPS are inconclusive. High‑accuracy assessments reinforce the benign interpretation: AlphaMissense‑Optimized scores benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts a benign impact on protein stability. Overall, the majority of evidence supports a benign effect for A322T, and this is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.175930Structured0.425745Uncertain0.9380.3340.000-2.252Likely Benign0.064Likely BenignLikely Benign0.58Ambiguous0.90.22Likely Benign0.40Likely Benign-0.52Ambiguous0.112Likely Benign0.20Neutral0.010Benign0.005Benign1.95Pathogenic0.73Tolerated0.13670.643210-2.530.03
c.3115A>G
I1039V
2D
AIThe SynGAP1 missense variant I1039V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.979204Binding0.2920.8060.625-2.455Likely Benign0.164Likely BenignLikely Benign0.060Likely Benign0.21Neutral0.264Benign0.048Benign2.76Benign0.41Tolerated0.14050.411243-0.3-14.03
c.3160G>A
G1054S
2D
AIThe SynGAP1 missense variant G1054S is listed in ClinVar (ID 699126.0) as Benign and is present in gnomAD (variant ID 6‑33443712‑G‑A). All evaluated in‑silico predictors classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool reports a pathogenic or likely pathogenic outcome. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts Benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the computational evidence strongly supports a benign effect, consistent with the ClinVar designation and not contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.878015Binding0.3890.9360.875Benign 16-33443712-G-A321.99e-5-5.294Likely Benign0.075Likely BenignLikely Benign0.160Likely Benign0.21Neutral0.121Benign0.013Benign4.04Benign0.63Tolerated3.7750.25060.531110-0.430.03
c.3173G>C
G1058A
2D
AIThe SynGAP1 missense variant G1058A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.980739Disordered0.885724Binding0.4070.9290.875-6.823Likely Benign0.082Likely BenignLikely Benign0.159Likely Benign0.21Neutral0.000Benign0.002Benign5.29Benign0.55Tolerated0.32880.5144102.214.03
c.346T>A
Y116N
2D
AIThe SynGAP1 missense variant Y116N is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.661982Disordered0.670235Binding0.3810.8780.625-1.706Likely Benign0.260Likely BenignLikely Benign0.108Likely Benign0.21Neutral0.137Benign0.021Benign4.27Benign1.00Tolerated0.25920.0545-2-2-2.2-49.07
c.1519A>C
K507Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant K507Q is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, PROVEAN, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. Uncertain results come from Rosetta, premPS, and ESM1b. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, is benign. Taken together, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.019401Structured0.262601Uncertain0.8850.2220.000-7.698In-Between0.180Likely BenignLikely Benign0.28Likely Benign0.0-0.70Ambiguous-0.21Likely Benign-0.52Ambiguous0.443Likely Benign0.22Neutral0.999Probably Damaging0.999Probably Damaging-1.52Pathogenic0.86Tolerated0.29520.0713110.4-0.04
c.34A>G
S12G
2D
AIThe SynGAP1 missense variant S12G is reported in gnomAD (ID 6‑33420298‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign status. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign effect for S12G, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.490599Uncertain0.3550.9160.5006-33420298-A-G-4.229Likely Benign0.093Likely BenignLikely Benign0.079Likely Benign0.22Neutral0.103Benign0.015Benign4.11Benign0.00Affected4.3210.28760.5080010.4-30.03
c.3139T>A
S1047T
2D
AIThe SynGAP1 missense variant S1047T is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign status. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.963420Disordered0.933764Binding0.4090.9090.750-4.222Likely Benign0.070Likely BenignLikely Benign0.029Likely Benign0.23Neutral0.069Benign0.049Benign2.63Benign0.63Tolerated0.17960.6265110.114.03
c.1586T>C
I529T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I529T is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus “Likely Benign” call. Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, predicts benign. Overall, the majority of evidence points to a benign effect, and this is consistent with the ClinVar “Uncertain” classification—there is no contradiction between the predictions and the current ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.318242Structured0.019545Uncertain0.9010.4030.000Uncertain 1-0.539Likely Benign0.336Likely BenignLikely Benign0.22Likely Benign0.20.16Likely Benign0.19Likely Benign0.17Likely Benign0.343Likely Benign0.24Neutral0.872Possibly Damaging0.820Possibly Damaging-1.23Pathogenic0.55Tolerated3.37350.08970.09890-1-5.2-12.05207.229.80.20.00.20.1XPotentially BenignIle529 is located on an α-α loop between the two α-helices (res. Gly502-Tyr518 and Ala533-Val560). In the WT simulations, the sec-butyl side chain of Ile529 faces the membrane interface and shows no specific interactions. In the variant simulations, the hydroxyl group of Thr529 forms a hydrogen bond with the carboxylate side chain of Asp527, but no negative structural changes are observed. However, due to its location near the SynGAP-membrane interface, the effect of the residue swap cannot be fully addressed using the SynGAP solvent-only simulations.
c.2570G>A
S857N
2D
AIThe SynGAP1 missense variant S857N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only two tools, polyPhen‑2 HumDiv and HumVar, predict a pathogenic outcome. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the consensus of the available predictions indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.728858Disordered0.475747Uncertain0.2880.8260.375-5.065Likely Benign0.137Likely BenignLikely Benign0.128Likely Benign0.24Neutral0.991Probably Damaging0.982Probably Damaging4.09Benign1.00Tolerated0.15150.503411-2.727.03
c.529T>C
F177L
2D
AIThe SynGAP1 missense variant F177L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. Tools that predict a pathogenic effect are AlphaMissense‑Default and AlphaMissense‑Optimized. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Pathogenic, while the SGM‑Consensus remains Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence (seven benign predictions versus two pathogenic) supports a benign classification. This conclusion does not contradict ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.505461Disordered0.461817Uncertain0.3570.5980.500-5.564Likely Benign0.994Likely PathogenicLikely Pathogenic0.184Likely Benign0.24Neutral0.022Benign0.022Benign4.41Benign1.00Tolerated0.23760.4280201.0-34.02
c.531T>A
F177L
2D
AIThe SynGAP1 missense variant F177L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. Tools that predict a pathogenic effect are AlphaMissense‑Default and AlphaMissense‑Optimized. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Pathogenic, while the SGM‑Consensus remains Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence (seven benign predictions versus two pathogenic) supports a benign classification. This conclusion does not contradict ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.505461Disordered0.461817Uncertain0.3570.5980.500-5.564Likely Benign0.994Likely PathogenicLikely Pathogenic0.173Likely Benign0.24Neutral0.022Benign0.022Benign4.41Benign1.00Tolerated0.23760.4280201.0-34.02
c.531T>G
F177L
2D
AIThe SynGAP1 missense variant F177L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. Tools that predict a pathogenic effect are AlphaMissense‑Default and AlphaMissense‑Optimized. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Pathogenic, while the SGM‑Consensus remains Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence (seven benign predictions versus two pathogenic) supports a benign classification. This conclusion does not contradict ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.505461Disordered0.461817Uncertain0.3570.5980.500-5.564Likely Benign0.994Likely PathogenicLikely Pathogenic0.173Likely Benign0.24Neutral0.022Benign0.022Benign4.41Benign1.00Tolerated0.23760.4280201.0-34.02
c.2257G>T
A753S
2D
AIThe SynGAP1 missense variant A753S is reported as “Likely Benign” in ClinVar and is not present in gnomAD. Prediction tools that assess functional impact all converge on a benign outcome: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool in the dataset predicts pathogenicity. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign effect. Foldetta results are unavailable. Overall, the variant is most likely benign, and this assessment does not contradict the ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.521092Disordered0.722781Binding0.3810.8730.625-3.656Likely Benign0.069Likely BenignLikely Benign0.105Likely Benign0.25Neutral0.062Benign0.015Benign3.03Benign0.59Tolerated0.29050.589911-2.616.00
c.2846G>A
G949D
2D
AIThe SynGAP1 missense variant G949D is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. The SGM Consensus, which takes a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (2 benign vs. 2 pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of high‑confidence predictors (5 pathogenic vs. 4 benign) indicate a pathogenic impact. This conclusion is not contradicted by ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988861Disordered0.874971Binding0.3650.9230.750-8.692Likely Pathogenic0.239Likely BenignLikely Benign0.316Likely Benign0.25Neutral0.945Possibly Damaging0.753Possibly Damaging2.21Pathogenic0.02Affected0.19270.28261-1-3.158.04
c.1406C>T
A469V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 A469V missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect comprise FoldX, Rosetta, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and Foldetta; premPS and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic, and Foldetta predicts pathogenic. With seven tools supporting pathogenicity versus four supporting benignity, the variant is most likely pathogenic, and this assessment does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.278302Structured0.343926Uncertain0.9100.2760.000-8.858Likely Pathogenic0.459AmbiguousLikely Benign2.30Destabilizing0.42.66Destabilizing2.48Destabilizing-0.77Ambiguous0.426Likely Benign0.26Neutral0.997Probably Damaging0.976Probably Damaging-1.20Pathogenic0.60Tolerated0.08270.5421002.428.05
c.2650C>T
R884W
2D
AIThe SynGAP1 missense variant R884W is listed in ClinVar with an “Uncertain” status and is present in the gnomAD database (gnomAD ID 6‑33443202‑C‑T). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. No Foldetta (protein‑folding stability) result is available for this variant. Overall, the majority of computational predictions, including the high‑accuracy tools, indicate that R884W is most likely benign, which is consistent with the ClinVar “Uncertain” status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.720929Disordered0.641526Binding0.3050.8980.250Uncertain 16-33443202-C-T53.10e-6-3.785Likely Benign0.332Likely BenignLikely Benign0.151Likely Benign0.26Neutral0.995Probably Damaging0.812Possibly Damaging2.56Benign0.05Affected4.3240.12230.3304-323.630.03
c.3164G>T
G1055V
2D
AIThe SynGAP1 missense variant G1055V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while ESM1b remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.872113Binding0.3790.9350.875-7.434In-Between0.114Likely BenignLikely Benign0.399Likely Benign0.26Neutral0.818Possibly Damaging0.222Benign3.28Benign0.17Tolerated0.13990.3694-1-34.642.08
c.3172G>A
G1058S
2D
AIThe SynGAP1 missense variant G1058S is listed in ClinVar with an “Uncertain” status and is present in gnomAD (variant ID 6-33443724-G-A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is also benign. Foldetta results are unavailable. Overall, the majority of computational evidence indicates that the variant is most likely benign, and this conclusion does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.980739Disordered0.885724Binding0.4070.9290.875Conflicting 36-33443724-G-A1147.08e-5-5.178Likely Benign0.081Likely BenignLikely Benign0.108Likely Benign0.26Neutral0.001Benign0.001Benign5.38Benign0.04Affected3.7750.24880.551110-0.430.03
c.269T>C
V90A
2D
AIThe SynGAP1 missense variant V90A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates that V90A is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.570702Disordered0.542047Binding0.3430.8730.500-0.984Likely Benign0.288Likely BenignLikely Benign0.055Likely Benign0.27Neutral0.053Benign0.008Benign4.11Benign0.00Affected0.31290.315400-2.4-28.05
c.3386T>C
L1129P
2D
AIThe SynGAP1 missense variant L1129P is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. The Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence—including high‑accuracy tools—points to a benign effect, and this conclusion does not contradict the current ClinVar “Uncertain” status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.903857Disordered0.876543Binding0.3390.9090.875Uncertain 2-2.991Likely Benign0.154Likely BenignLikely Benign0.432Likely Benign0.27Neutral0.971Probably Damaging0.773Possibly Damaging5.44Benign0.00Affected4.3240.30170.2231-3-3-5.4-16.04
c.1060G>T
A354S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A354S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: SGM‑Consensus (Likely Benign), REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign; the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also reports a benign effect. Taken together, the overwhelming majority of evidence indicates that A354S is most likely benign, and this conclusion is consistent with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.203355Structured0.381329Uncertain0.8820.3350.125-3.005Likely Benign0.081Likely BenignLikely Benign0.02Likely Benign0.10.27Likely Benign0.15Likely Benign-0.10Likely Benign0.071Likely Benign0.28Neutral0.005Benign0.001Benign1.76Pathogenic0.21Tolerated0.28290.511711-2.616.00
c.3044C>A
T1015N
2D
AIThe SynGAP1 missense variant T1015N is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification—there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.928486Binding0.2950.8230.625-4.353Likely Benign0.110Likely BenignLikely Benign0.027Likely Benign0.28Neutral0.004Benign0.002Benign2.54Benign0.24Tolerated0.16880.423300-2.813.00
c.3832C>T
P1278S
2D
AIThe SynGAP1 missense variant P1278S is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.806955Binding0.5320.7220.750-4.383Likely Benign0.098Likely BenignLikely Benign0.077Likely Benign0.28Neutral0.004Benign0.003Benign2.96Benign0.35Tolerated0.36160.36971-10.8-10.04
c.3871C>G
L1291V
2D
AIThe SynGAP1 missense variant L1291V is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity, so the pathogenic prediction group is empty. High‑accuracy assessments corroborate this benign consensus: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this prediction aligns with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.827927Disordered0.863458Binding0.5790.7970.625-4.583Likely Benign0.103Likely BenignLikely Benign0.028Likely Benign0.28Neutral0.149Benign0.064Benign2.61Benign0.07Tolerated0.14350.2946210.4-14.03
c.3979C>T
P1327S
2D
AIThe SynGAP1 missense variant P1327S is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33451853‑C‑T). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.896620Disordered0.900145Binding0.3690.7770.875Uncertain 16-33451853-C-T-4.744Likely Benign0.131Likely BenignLikely Benign0.092Likely Benign0.28Neutral0.980Probably Damaging0.857Possibly Damaging4.25Benign0.71Tolerated3.7750.30980.40251-10.8-10.04
c.3160G>C
G1054R
2D
AIThe SynGAP1 missense variant G1054R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for G1054R, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.878015Binding0.3890.9360.875-8.863Likely Pathogenic0.326Likely BenignLikely Benign0.234Likely Benign0.29Neutral0.988Probably Damaging0.589Possibly Damaging4.05Benign0.42Tolerated0.11640.4342-3-2-4.199.14
c.359G>C
G120A
2D
AIThe SynGAP1 missense variant G120A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.659993Binding0.3590.8870.750-3.477Likely Benign0.062Likely BenignLikely Benign0.027Likely Benign0.29Neutral0.000Benign0.000Benign4.37Benign1.00Tolerated0.40030.4565102.214.03
c.3973C>T
P1325S
2D
AIThe SynGAP1 missense variant P1325S is reported in gnomAD (ID 6‑33451847‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.893621Binding0.4390.7910.8756-33451847-C-T16.43e-7-5.273Likely Benign0.083Likely BenignLikely Benign0.053Likely Benign0.29Neutral0.010Benign0.007Benign4.10Benign0.00Affected4.3210.36570.4360-110.8-10.04
c.4024G>A
D1342N
2D
AIThe SynGAP1 missense variant D1342N is catalogued in gnomAD (ID 6‑33451898‑G‑A) but has no ClinVar submission. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the substitution as tolerated or benign. Grouping by consensus, all listed predictors fall into the benign category, with no tool reporting pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta stability analysis is unavailable for this variant. Consequently, the aggregate evidence strongly supports a benign classification, and this assessment does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.921076Disordered0.981682Binding0.3160.6780.8756-33451898-G-A-3.459Likely Benign0.140Likely BenignLikely Benign0.058Likely Benign0.29Neutral0.000Benign0.002Benign4.07Benign0.93Tolerated4.3240.18680.6022120.0-0.98
c.1721T>G
L574R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L574R is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, SIFT, polyPhen‑2 HumVar, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, ESM1b, and FATHMM. Two tools remain inconclusive: Rosetta (Uncertain) and AlphaMissense‑Default (Uncertain). High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic. Overall, the majority of individual predictors (seven benign vs. three pathogenic) support a benign classification, and this conclusion does not contradict the ClinVar status, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.083462Structured0.026427Uncertain0.9270.2460.000-8.702Likely Pathogenic0.563AmbiguousLikely Benign0.04Likely Benign0.20.88Ambiguous0.46Likely Benign-0.12Likely Benign0.322Likely Benign0.30Neutral0.907Possibly Damaging0.292Benign-1.22Pathogenic0.52Tolerated0.14190.0530-3-2-8.343.03
c.2845G>A
G949S
2D
AIThe SynGAP1 missense variant G949S is listed in ClinVar as a benign alteration (ClinVar ID 212352.0) and is present in the gnomAD database (6‑33443397‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as likely benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, aligning with the ClinVar classification and indicating no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988861Disordered0.874971Binding0.3650.9230.750Benign/Likely benign 46-33443397-G-A1227.56e-5-5.693Likely Benign0.072Likely BenignLikely Benign0.321Likely Benign0.30Neutral0.611Possibly Damaging0.102Benign2.23Pathogenic0.00Affected4.3240.25280.515910-0.430.0310.1016/j.ajhg.2020.11.011
c.3179G>C
G1060A
2D
AIThe SynGAP1 missense variant G1060A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic outcome, creating a single discordant signal. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979242Disordered0.913048Binding0.4070.9280.875-6.539Likely Benign0.082Likely BenignLikely Benign0.341Likely Benign0.30Neutral0.664Possibly Damaging0.283Benign2.69Benign0.98Tolerated0.33350.4944102.214.03
c.17C>G
A6G
2D
AIThe SynGAP1 missense variant A6G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.566480Disordered0.549054Binding0.3770.9200.875-2.786Likely Benign0.097Likely BenignLikely Benign0.107Likely Benign0.31Neutral0.052Benign0.004Benign4.08Benign0.00Affected0.21390.436910-2.2-14.03
c.2746G>C
V916L
2D
AIThe SynGAP1 missense variant V916L is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.642678Disordered0.835395Binding0.3080.8790.250-2.645Likely Benign0.086Likely BenignLikely Benign0.064Likely Benign0.31Neutral0.001Benign0.002Benign2.73Benign0.09Tolerated0.11900.532321-0.414.03
c.17C>T
A6V
2D
AIThe SynGAP1 A6V missense variant is reported in gnomAD (ID 6‑33420281‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) labels it “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign; Foldetta results are not available. Overall, the preponderance of evidence indicates the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.566480Disordered0.549054Binding0.3770.9200.8756-33420281-C-T-3.781Likely Benign0.191Likely BenignLikely Benign0.123Likely Benign0.32Neutral0.117Benign0.007Benign4.09Benign0.00Affected4.3210.09870.5799002.428.05
c.2404G>A
G802S
2D
AIThe SynGAP1 missense variant G802S is catalogued in gnomAD (allele ID 6‑33442956‑G‑A) but has no entry in ClinVar. Functional prediction tools that assess evolutionary conservation and structural impact (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized) all uniformly predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments further support this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no reported result for this variant, so it does not influence the assessment. **Overall, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.**

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.894241Disordered0.681966Binding0.2940.8980.6256-33442956-G-A16.20e-7-2.663Likely Benign0.078Likely BenignLikely Benign0.098Likely Benign0.32Neutral0.001Benign0.006Benign2.83Benign0.06Tolerated3.7750.26820.520801-0.430.03
c.304T>G
L102V
2D
AIThe SynGAP1 missense variant L102V is listed in ClinVar (ID 1925749.0) with an “Uncertain” status and is present in gnomAD (6‑33432169‑T‑G). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This consensus does not contradict the ClinVar “Uncertain” classification, which remains inconclusive.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.696014Binding0.3570.8850.625Uncertain 16-33432169-T-G16.20e-7-4.316Likely Benign0.068Likely BenignLikely Benign0.102Likely Benign0.32Neutral0.880Possibly Damaging0.899Possibly Damaging4.21Benign0.00Affected4.3210.16830.3671210.4-14.03
c.1597G>T
A533S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A533S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only FATHMM predicts a pathogenic outcome. When predictions are grouped by consensus, the benign group contains all tools except FATHMM, which stands alone in the pathogenic group. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized reports benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields “Likely Benign,” and Foldetta (combining FoldX‑MD and Rosetta outputs) also indicates a benign effect. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.179055Structured0.026324Uncertain0.8430.3930.000-3.740Likely Benign0.075Likely BenignLikely Benign0.24Likely Benign0.0-0.05Likely Benign0.10Likely Benign-0.14Likely Benign0.193Likely Benign0.33Neutral0.009Benign0.039Benign-1.14Pathogenic0.45Tolerated0.26120.533411-2.616.00
c.2837G>C
G946A
2D
AIThe SynGAP1 missense variant G946A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for G946A, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985417Disordered0.845792Binding0.3570.9200.750-7.004In-Between0.079Likely BenignLikely Benign0.191Likely Benign0.33Neutral0.649Possibly Damaging0.209Benign4.77Benign0.00Affected0.33780.4957102.214.03
c.3188G>C
G1063A
2D
AIThe SynGAP1 missense variant G1063A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975134Disordered0.945784Binding0.3940.9130.875-5.373Likely Benign0.079Likely BenignLikely Benign0.045Likely Benign0.33Neutral0.000Benign0.002Benign4.30Benign0.12Tolerated0.33480.4957102.214.03
c.17C>A
A6D
2D
AIThe SynGAP1 missense variant A6D is reported in gnomAD (ID 6‑33420281‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) labels it “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign; Foldetta results are not available. Overall, the consensus of the majority of tools, including the high‑accuracy methods, indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.566480Disordered0.549054Binding0.3770.9200.8756-33420281-C-A-3.340Likely Benign0.210Likely BenignLikely Benign0.211Likely Benign0.34Neutral0.117Benign0.010Benign4.07Benign0.00Affected4.3210.19450.2530-20-5.344.01
c.2699C>G
T900R
2D
AIThe SynGAP1 missense variant T900R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and AlphaMissense‑Default predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the majority of computational evidence points to a benign effect, and this is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.465347Uncertain0.2890.9240.375-3.340Likely Benign0.617Likely PathogenicLikely Benign0.109Likely Benign0.34Neutral0.782Possibly Damaging0.530Possibly Damaging2.68Benign0.83Tolerated0.10270.2851-1-1-3.855.08
c.2827G>A
G943S
2D
AIThe SynGAP1 missense variant G943S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign. Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.973328Disordered0.860437Binding0.3720.9100.750-5.785Likely Benign0.079Likely BenignLikely Benign0.295Likely Benign0.34Neutral0.059Benign0.039Benign2.88Benign0.51Tolerated0.24820.550210-0.430.03
c.3172G>C
G1058R
2D
AIThe SynGAP1 missense variant G1058R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only two predictors—SIFT and ESM1b—suggest a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign consensus. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not conflict with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.980739Disordered0.885724Binding0.4070.9290.875-8.967Likely Pathogenic0.339Likely BenignLikely Benign0.138Likely Benign0.34Neutral0.174Benign0.140Benign5.29Benign0.00Affected0.11450.4342-3-2-4.199.14
c.3901C>A
P1301T
2D
AIThe SynGAP1 missense variant P1301T is reported in gnomAD (ID 6‑33451775‑C‑A) and has no ClinVar entry. All evaluated in silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this benign prediction: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are unavailable. Based on the consensus of all available predictions, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.728858Disordered0.885064Binding0.4470.8410.8756-33451775-C-A16.20e-7-4.945Likely Benign0.075Likely BenignLikely Benign0.090Likely Benign0.34Neutral0.000Benign0.001Benign2.87Benign0.47Tolerated3.7750.12550.3312-100.93.99
c.1297G>T
A433S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A433S is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate benign or likely benign. Only polyPhen‑2 (HumDiv) predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized reports benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a likely benign classification; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also predicts benign. Overall, the preponderance of evidence points to a benign impact for A433S, and this conclusion is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.098513Structured0.352258Uncertain0.9380.3020.000-3.861Likely Benign0.077Likely BenignLikely Benign-0.04Likely Benign0.00.41Likely Benign0.19Likely Benign-0.21Likely Benign0.077Likely Benign0.35Neutral0.597Possibly Damaging0.391Benign3.46Benign0.28Tolerated0.19380.397511-2.616.00
c.370G>T
A124S
2D
AIThe SynGAP1 missense variant A124 S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.509769Disordered0.699139Binding0.3400.8830.750-1.933Likely Benign0.101Likely BenignLikely Benign0.053Likely Benign0.35Neutral0.849Possibly Damaging0.303Benign4.22Benign0.65Tolerated0.30180.619211-2.616.00
c.3970C>T
P1324S
2D
AIThe SynGAP1 missense variant P1324S is listed in ClinVar as Benign (ClinVar ID 1137951.0) and is present in gnomAD (ID 6‑33451844‑C‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote) also benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, which is consistent with its ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.891961Disordered0.899181Binding0.4320.7930.875Likely Benign 16-33451844-C-T53.26e-6-5.451Likely Benign0.068Likely BenignLikely Benign0.049Likely Benign0.35Neutral0.225Benign0.092Benign4.33Benign0.00Affected4.3210.35050.44501-10.8-10.04
c.2819G>T
G940V
2D
AIThe SynGAP1 missense variant G940V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Overall, the consensus of available predictions points to a benign impact, and this is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.920635Binding0.3830.9020.625-6.252Likely Benign0.078Likely BenignLikely Benign0.110Likely Benign0.36Neutral0.626Possibly Damaging0.419Benign2.92Benign0.31Tolerated0.12220.3822-1-34.642.08
c.3910C>T
P1304S
2D
AIThe SynGAP1 missense variant P1304S is reported in gnomAD (ID 6‑33451784‑C‑T) but has no ClinVar entry. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is provided).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.885302Disordered0.886417Binding0.4750.8660.8756-33451784-C-T16.20e-7-4.103Likely Benign0.077Likely BenignLikely Benign0.039Likely Benign0.36Neutral0.059Benign0.041Benign3.03Benign0.58Tolerated3.7750.29000.4442-110.8-10.04
c.2098C>G
L700V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L700V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates a likely benign outcome. In contrast, protein‑stability methods predict a deleterious impact: FoldX and Rosetta both score the variant as pathogenic, and the combined Foldetta analysis (FoldX‑MD + Rosetta) also reports a pathogenic effect. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as likely benign, while Foldetta remains pathogenic. Overall, the majority of predictions support a benign classification, and this is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.113710Structured0.416255Uncertain0.9270.3310.000-3.703Likely Benign0.192Likely BenignLikely Benign2.52Destabilizing0.03.16Destabilizing2.84Destabilizing0.13Likely Benign0.056Likely Benign0.37Neutral0.003Benign0.005Benign3.46Benign0.76Tolerated0.14240.2460210.4-14.03
c.323A>G
K108R
2D
AIThe SynGAP1 missense variant K108R is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33432188‑A‑G). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments further support benignity: AlphaMissense‑Optimized is benign, and the SGM‑Consensus itself is benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.626927Disordered0.673331Binding0.3380.8580.875Uncertain 16-33432188-A-G63.72e-6-2.892Likely Benign0.148Likely BenignLikely Benign0.184Likely Benign0.37Neutral0.993Probably Damaging0.956Probably Damaging4.22Benign1.00Tolerated3.6150.52860.1229Weaken32-0.628.01
c.3835G>T
A1279S
2D
AIThe SynGAP1 missense variant A1279S is catalogued in gnomAD (ID 6‑33447883‑G‑T) but has no ClinVar entry. Across the spectrum of in‑silico predictors, every tool listed—REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—consistently scores the substitution as benign. No pathogenic predictions are reported. Grouping by agreement, the benign‑predicting tools comprise the entire set, while the pathogenic group is empty. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status is unavailable. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.842060Disordered0.814139Binding0.4850.7240.7506-33447883-G-T-4.281Likely Benign0.073Likely BenignLikely Benign0.134Likely Benign0.37Neutral0.019Benign0.019Benign2.74Benign0.16Tolerated3.7750.21660.458311-2.616.00
c.1100T>A
L367Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L367Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that indicate a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, AlphaMissense‑Default, AlphaMissense‑Optimized, and ESM1b. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus also as benign, while Foldetta (combining FoldX‑MD and Rosetta outputs) yields an uncertain result. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation; there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.370445Structured0.441805Uncertain0.7900.6570.250-3.432Likely Benign0.150Likely BenignLikely Benign1.09Ambiguous0.31.63Ambiguous1.36Ambiguous0.31Likely Benign0.061Likely Benign0.38Neutral0.002Benign0.002Benign1.65Pathogenic0.02Affected0.16150.0973-2-2-7.314.97
c.2335A>G
S779G
2D
AIThe SynGAP1 missense variant S779G is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly supports a benign classification, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.509769Disordered0.834974Binding0.3210.8900.375-4.304Likely Benign0.111Likely BenignLikely Benign0.103Likely Benign0.38Neutral0.393Benign0.324Benign2.65Benign0.53Tolerated0.28940.5087100.4-30.03
c.3394T>C
S1132P
2D
AIThe SynGAP1 missense variant S1132P is listed in ClinVar with an uncertain significance (ClinVar ID 1341927.0) and is present in the gnomAD database (gnomAD ID 6‑33443946‑T‑C). All available in‑silico predictors uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign or likely benign outcomes. No tool in the dataset predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status is unavailable. Overall, the computational evidence strongly supports a benign effect, which is consistent with the ClinVar uncertain classification rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.845506Binding0.2890.8940.750Conflicting 36-33443946-T-C16.74e-7-1.423Likely Benign0.144Likely BenignLikely Benign0.301Likely Benign0.38Neutral0.003Benign0.006Benign5.40Benign0.28Tolerated4.3240.20810.57001-1-0.810.04
c.137C>G
P46R
2D
AIThe SynGAP1 missense variant P46R is catalogued in gnomAD (ID 6‑33423546‑C‑G) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions come from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default is uncertain, and Foldetta (FoldX‑MD/Rosetta stability assessment) has no available result. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta data is missing. Overall, the majority of evidence points to a benign effect. There is no ClinVar status to contradict this conclusion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.390993Structured0.433588Uncertain0.5490.7410.3756-33423546-C-G16.20e-7-0.520Likely Benign0.385AmbiguousLikely Benign0.155Likely Benign0.39Neutral0.972Probably Damaging0.954Probably Damaging4.39Benign0.00Affected4.3210.16690.4543-20-2.959.07
c.1753G>T
A585S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A585S is not reported in ClinVar (no entry) and is absent from gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. FoldX, Rosetta, and Foldetta are inconclusive. High‑accuracy methods give a benign consensus: AlphaMissense‑Optimized predicts benign, SGM‑Consensus predicts Likely Benign, while Foldetta remains uncertain. Overall, the majority of evidence supports a benign classification, and this assessment does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.060549Structured0.055884Uncertain0.8800.2440.000-6.332Likely Benign0.246Likely BenignLikely Benign0.91Ambiguous0.21.44Ambiguous1.18Ambiguous0.02Likely Benign0.326Likely Benign0.39Neutral0.993Probably Damaging0.996Probably Damaging-1.27Pathogenic0.98Tolerated0.21210.338811-2.616.00
c.3305C>G
A1102G
2D
AIThe SynGAP1 A1102G missense variant is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome. The high‑accuracy consensus (SGM‑Consensus) classifies the variant as “Likely Benign,” and AlphaMissense‑Optimized also reports a benign prediction. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.915074Disordered0.962659Binding0.3880.8590.875-3.070Likely Benign0.078Likely BenignLikely Benign0.060Likely Benign0.39Neutral0.000Benign0.001Benign2.30Pathogenic0.14Tolerated0.19470.495810-2.2-14.03
c.1327G>A
G443S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G443S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree that the substitution is benign: REVEL, FoldX, PROVEAN, polyPhen‑2 (both HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify it as benign. Only Rosetta and premPS yield uncertain results, which are treated as unavailable. Grouping by consensus, the benign‑predicting tools outnumber any pathogenic calls (none). High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) also reports benign. Therefore, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.250310Structured0.258623Uncertain0.9350.2060.000-1.258Likely Benign0.086Likely BenignLikely Benign0.25Likely Benign0.1-0.72Ambiguous-0.24Likely Benign-0.65Ambiguous0.087Likely Benign0.40Neutral0.000Benign0.001Benign3.51Benign0.34Tolerated0.24090.341610-0.430.03
c.3110T>C
I1037T
2D
AIThe SynGAP1 missense variant I1037T is not reported in ClinVar (ClinVar ID None) but is present in gnomAD (ID 6‑33443662‑T‑C). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. Tools that predict a pathogenic effect are AlphaMissense‑Default and AlphaMissense‑Optimized. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic, while the SGM‑Consensus remains Likely Benign; Foldetta results are unavailable. Overall, the majority of predictions (seven benign vs. two pathogenic) indicate that the variant is most likely benign, and this assessment does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.6256-33443662-T-C16.21e-7-2.565Likely Benign0.973Likely PathogenicLikely Pathogenic0.066Likely Benign0.40Neutral0.292Benign0.110Benign2.79Benign0.34Tolerated3.7750.10710.2175-10-5.2-12.05
c.511G>T
A171S
2D
AIThe SynGAP1 missense variant A171S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.562014Disordered0.492272Uncertain0.3580.6520.375-0.011Likely Benign0.115Likely BenignLikely Benign0.054Likely Benign0.40Neutral0.002Benign0.001Benign4.33Benign0.91Tolerated0.22210.438311-2.616.00
c.11C>G
S4C
2D
AIThe SynGAP1 missense variant S4C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for S4C, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.608892Disordered0.547364Binding0.3900.9240.750-5.210Likely Benign0.124Likely BenignLikely Benign0.106Likely Benign0.41Neutral0.880Possibly Damaging0.700Possibly Damaging4.11Benign0.00Affected0.09760.61290-13.316.06
c.20C>G
S7C
2D
AIThe SynGAP1 missense variant S7C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus, SGM‑Consensus, is derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, all of which are benign, and therefore SGM‑Consensus also predicts benign. AlphaMissense‑Optimized independently predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from both general and high‑accuracy tools indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.590140Disordered0.548467Binding0.3860.9220.750-5.066Likely Benign0.125Likely BenignLikely Benign0.111Likely Benign0.41Neutral0.000Benign0.000Benign4.05Benign0.00Affected0.12310.56720-13.316.06
c.2350G>T
A784S
2D
AIThe SynGAP1 missense variant A784S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools that assess sequence conservation and structural impact uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the collective evidence strongly supports a benign classification, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.801317Disordered0.708872Binding0.3140.8960.625-2.233Likely Benign0.094Likely BenignLikely Benign0.027Likely Benign0.41Neutral0.004Benign0.010Benign2.72Benign0.67Tolerated0.26240.517111-2.616.00
c.2530C>A
L844M
2D
AIThe SynGAP1 missense variant L844M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.595080Disordered0.611301Binding0.3040.8350.3751.261Likely Benign0.213Likely BenignLikely Benign0.027Likely Benign0.42Neutral0.052Benign0.046Benign2.72Benign0.38Tolerated0.08720.412242-1.918.03
c.2791C>A
L931I
2D
AIThe SynGAP1 missense variant L931I is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 HumDiv and polyPhen‑2 HumVar both predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from multiple prediction algorithms indicates that the variant is most likely benign, and this conclusion does not contradict the lack of ClinVar reporting.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.549308Disordered0.989212Binding0.3350.8560.375-3.813Likely Benign0.296Likely BenignLikely Benign0.120Likely Benign0.42Neutral0.999Probably Damaging0.994Probably Damaging2.58Benign0.14Tolerated0.10760.3540220.70.00
c.3965C>G
A1322G
2D
AIThe SynGAP1 missense variant A1322G is catalogued in gnomAD (ID 6‑33451839‑C‑G) but has no ClinVar entry. Across a broad panel of in silico predictors, every tool reports a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool in the set predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized indicates a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports a likely benign status. Foldetta results are not available for this variant. Consequently, the variant is most likely benign, and this prediction does not contradict any ClinVar classification (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.921040Binding0.4660.8250.8756-33451839-C-G-4.159Likely Benign0.086Likely BenignLikely Benign0.053Likely Benign0.42Neutral0.005Benign0.002Benign4.16Benign0.62Tolerated3.7750.21600.474101-2.2-14.03
c.56C>T
A19V
2D
AIThe SynGAP1 missense variant A19V is reported in gnomAD (ID 6‑33420320‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is likely benign; Foldetta results are unavailable. Overall, the consensus of available predictions points to a benign impact for A19V, and this conclusion is not contradicted by ClinVar status, which currently lacks an entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.529623Disordered0.443393Uncertain0.3780.9060.5006-33420320-C-T-3.157Likely Benign0.095Likely BenignLikely Benign0.063Likely Benign0.42Neutral0.371Benign0.036Benign4.27Benign0.00Affected4.3210.18040.6942002.428.05
c.3110T>G
I1037S
2D
AIThe SynGAP1 missense variant I1037S is not reported in ClinVar and has no entries in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), which classifies the variant as Likely Benign. Only AlphaMissense‑Default predicts a pathogenic outcome, while AlphaMissense‑Optimized is uncertain and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta) has no available result for this variant. Based on the overall consensus of the majority of tools, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-2.247Likely Benign0.935Likely PathogenicAmbiguous0.120Likely Benign0.43Neutral0.032Benign0.017Benign2.83Benign0.27Tolerated0.26340.1110-1-2-5.3-26.08
c.3157A>C
S1053R
2D
AIThe SynGAP1 missense variant S1053R is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority‑vote SGM‑Consensus also reports a likely benign outcome. In contrast, the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy analyses reinforce the benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is likely benign, with no contradictory Foldetta data. Overall, the preponderance of evidence points to a benign effect for S1053R, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.875-6.421Likely Benign0.359AmbiguousLikely Benign0.225Likely Benign0.43Neutral0.969Probably Damaging0.581Possibly Damaging5.33Benign0.59Tolerated3.7750.13210.3820-10-3.769.11
c.3159C>A
S1053R
2D
AIThe SynGAP1 missense variant S1053R is reported in gnomAD (variant ID 6‑33443711‑C‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. Overall, the majority of high‑accuracy predictors and consensus analyses indicate a benign impact. Thus, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.8756-33443711-C-A11.10e-6-6.421Likely Benign0.359AmbiguousLikely Benign0.303Likely Benign0.43Neutral0.969Probably Damaging0.581Possibly Damaging5.33Benign0.59Tolerated3.7750.13210.3820-10-3.769.11
c.3159C>G
S1053R
2D
AIThe SynGAP1 missense variant S1053R is reported in gnomAD (ID 6‑33443711‑C‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and the high‑accuracy consensus methods give a benign verdict: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports “Likely Benign.” Foldetta, a protein‑folding stability predictor combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact. The predictions do not contradict any ClinVar status, as none is currently assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.8756-33443711-C-G-6.421Likely Benign0.359AmbiguousLikely Benign0.304Likely Benign0.43Neutral0.969Probably Damaging0.581Possibly Damaging5.33Benign0.59Tolerated3.7750.13210.3820-10-3.769.11
c.2692T>C
S898P
2D
AIThe SynGAP1 missense variant S898P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are not available. Overall, the majority of predictions (six benign vs. four pathogenic) support a benign classification. There is no ClinVar entry to contradict this assessment, so the variant is most likely benign based on current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.690604Disordered0.426070Uncertain0.3050.9220.500-4.192Likely Benign0.307Likely BenignLikely Benign0.149Likely Benign0.44Neutral0.998Probably Damaging0.939Probably Damaging2.45Pathogenic0.01Affected0.24000.65551-1-0.810.04
c.1663G>A
V555I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V555I is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Prediction tools that uniformly indicate a benign effect include REVEL, Rosetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Only FATHMM predicts a pathogenic outcome, while FoldX, Foldetta, and premPS are inconclusive. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Benign, and Foldetta as uncertain. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.013265Structured0.008218Uncertain0.9430.2250.000Uncertain 1-4.544Likely Benign0.084Likely BenignLikely Benign-0.82Ambiguous0.0-0.41Likely Benign-0.62Ambiguous-0.55Ambiguous0.253Likely Benign0.45Neutral0.002Benign0.002Benign-1.26Pathogenic1.00Tolerated0.08440.2590430.314.03
c.2818G>A
G940S
2D
AIThe SynGAP1 missense variant G940S is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443370‑G‑A). All available in silico predictors agree on a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” High‑accuracy tools reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no reported result for this variant, so its status is unavailable. Overall, the computational evidence strongly supports a benign classification, which does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.920635Binding0.3830.9020.625Uncertain 16-33443370-G-A16.20e-7-5.451Likely Benign0.084Likely BenignLikely Benign0.135Likely Benign0.45Neutral0.409Benign0.253Benign2.77Benign0.44Tolerated3.7750.25900.490710-0.430.03
c.3116T>C
I1039T
2D
AIThe SynGAP1 missense variant I1039T is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443668‑T‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM; the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports a likely benign outcome. Only AlphaMissense‑Default predicts a pathogenic effect. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign, while a Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this is consistent with the ClinVar “Uncertain” classification rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.979204Binding0.2920.8060.625Uncertain 26-33443668-T-C127.43e-6-2.465Likely Benign0.645Likely PathogenicLikely Benign0.193Likely Benign0.45Neutral0.004Benign0.008Benign2.75Benign0.10Tolerated3.7750.12480.2293-10-5.2-12.05
c.3919C>T
P1307S
2D
AIThe SynGAP1 missense variant P1307S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.798249Disordered0.913511Binding0.4910.9010.875-3.700Likely Benign0.093Likely BenignLikely Benign0.049Likely Benign0.45Neutral0.239Benign0.157Benign3.09Benign0.48Tolerated0.36520.48461-10.8-10.04
c.1964T>G
L655R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L655R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools uniformly indicate a benign effect: SIFT, PolyPhen‑2 (HumDiv and HumVar), REVEL, PROVEAN, premPS, FoldX, and the majority of consensus methods (AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all score the variant as benign. The only inconclusive result comes from Rosetta, which is treated as unavailable. High‑accuracy assessments reinforce this benign prediction: AlphaMissense‑Optimized reports benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is “Likely Benign,” and Foldetta (combining FoldX‑MD and Rosetta outputs) also predicts benign. Thus, based on the available predictions, the variant is most likely benign, with no conflict with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.015344Structured0.268808Uncertain0.9610.2740.000-4.848Likely Benign0.284Likely BenignLikely Benign-0.40Likely Benign0.00.54Ambiguous0.07Likely Benign-0.09Likely Benign0.160Likely Benign0.46Neutral0.006Benign0.001Benign3.50Benign0.60Tolerated0.15890.0615-3-2-8.343.03
c.2848G>A
G950S
2D
AIThe SynGAP1 missense variant G950S is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; the Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.888649Binding0.3680.9230.750-5.286Likely Benign0.071Likely BenignLikely Benign0.288Likely Benign0.46Neutral0.004Benign0.008Benign2.32Pathogenic0.52Tolerated0.24590.550210-0.430.03
c.44C>A
A15E
2D
AIThe SynGAP1 missense variant A15E is reported in gnomAD (ID 6‑33420308‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is provided).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.436924Structured0.466055Uncertain0.3300.9120.3756-33420308-C-A-3.423Likely Benign0.277Likely BenignLikely Benign0.169Likely Benign0.46Neutral0.406Benign0.040Benign4.13Benign0.00Affected4.3210.15630.1908-10-5.358.04
c.1108G>A
G370S
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant G370S is listed in ClinVar with an uncertain significance and is present in gnomAD (variant ID 6‑33438013‑G‑A). Consensus predictions from standard in silico tools cluster into two groups: benign (REVEL, premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized) and pathogenic (FoldX, FATHMM). Two tools report uncertainty: Rosetta and Foldetta. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is Likely Benign; Foldetta remains uncertain. Overall, the preponderance of evidence points to a benign effect, which does not contradict the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.461924Structured0.434325Uncertain0.3590.7200.500Uncertain 16-33438013-G-A159.31e-6-3.533Likely Benign0.081Likely BenignLikely Benign2.83Destabilizing2.01.05Ambiguous1.94Ambiguous-0.02Likely Benign0.282Likely Benign0.47Neutral0.000Benign0.000Benign1.33Pathogenic0.77Tolerated3.42190.26640.508610-0.430.03196.6-49.60.92.2-0.10.4UncertainGly370 is located in the Gly-rich Ω loop (res. Pro364- Pro398) between two anti-parallel β sheet strands (res. Thr359-Pro364, res. Ala399-Ile411). Because, the Ω loop is assumed to be directly interacting with the membrane, it is only seen to move arbitrarily throughout the WT solvent simulations. The Ω loop is potentially playing a crucial loop in the SynGAP-membrane complex association, stability and dynamics, regardless, this aspect cannot be addressed through the solvent simulations only. The Ω-loops are known to have a major role in protein functions that requires flexibility and thus, they are rich in glycines, prolines and to a lesser extent, hydrophilic residues to ensure maximum flexibility. Thus, Ser370 in the variant is potentially tolerated in the Ω loop. However, since the effect on the Gly-rich Ω loop dynamics can only be well-studied through the SynGAP-membrane complex, no definite conclusions can be withdrawn.
c.2020A>T
T674S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T674S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools uniformly indicate a benign effect: SIFT, PolyPhen‑2 (HumDiv and HumVar), REVEL, PROVEAN, premPS, FoldX, Rosetta, and AlphaMissense‑Default all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also reports a benign effect. With all available evidence pointing to a benign outcome and no conflicting ClinVar annotation, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.129801Structured0.109297Uncertain0.5210.3490.000-5.320Likely Benign0.082Likely BenignLikely Benign-0.23Likely Benign0.00.44Likely Benign0.11Likely Benign-0.14Likely Benign0.084Likely Benign0.47Neutral0.107Benign0.033Benign3.47Benign1.00Tolerated0.33290.493811-0.1-14.03
c.2021C>G
T674S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T674S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools uniformly indicate a benign effect: SIFT, PolyPhen‑2 (HumDiv and HumVar), REVEL, PROVEAN, premPS, FoldX, Rosetta, and AlphaMissense‑Default all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also reports a benign effect. With all available evidence pointing to a benign outcome and no conflicting ClinVar annotation, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.129801Structured0.109297Uncertain0.5210.3490.000-5.320Likely Benign0.082Likely BenignLikely Benign-0.23Likely Benign0.00.44Likely Benign0.11Likely Benign-0.14Likely Benign0.088Likely Benign0.47Neutral0.107Benign0.033Benign3.47Benign1.00Tolerated0.33290.493811-0.1-14.03
c.2269G>A
G757S
2D
AIThe SynGAP1 missense variant G757S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools that assess pathogenicity uniformly predict a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate benign. No tool in the dataset predicts pathogenicity. The high‑accuracy consensus methods likewise support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Overall, the collective predictions strongly suggest that the variant is most likely benign, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.436924Structured0.830995Binding0.3100.8690.375-1.492Likely Benign0.071Likely BenignLikely Benign0.058Likely Benign0.47Neutral0.007Benign0.008Benign2.73Benign0.29Tolerated0.25950.387710-0.430.03
c.598T>A
L200M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L200M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all indicate a benign outcome. Only two tools, polyPhen‑2 HumDiv and HumVar, predict pathogenicity. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign; the SGM‑Consensus, derived from the four high‑confidence predictors, is benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also reports a benign effect. Taken together, the overwhelming majority of evidence supports a benign classification for L200M, and this conclusion is consistent with the absence of a ClinVar entry. Thus, the variant is most likely benign, and this assessment does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.366687Structured0.428168Uncertain0.6870.4530.125-4.107Likely Benign0.215Likely BenignLikely Benign0.08Likely Benign0.10.41Likely Benign0.25Likely Benign-0.25Likely Benign0.139Likely Benign0.47Neutral0.997Probably Damaging0.960Probably Damaging4.11Benign0.31Tolerated0.07510.351142-1.918.03
c.1345A>T
S449C
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S449C is not reported in ClinVar and is absent from gnomAD. All evaluated in‑silico predictors classify the substitution as benign: REVEL, FoldX, Rosetta, premPS (uncertain), PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments concur: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates likely benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also reports a benign effect. Based on the unanimous benign predictions and lack of ClinVar evidence, the variant is most likely benign, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.254060Structured0.301437Uncertain0.9580.2510.000-2.207Likely Benign0.050Likely BenignLikely Benign0.48Likely Benign0.0-0.31Likely Benign0.09Likely Benign-0.57Ambiguous0.067Likely Benign0.48Neutral0.000Benign0.000Benign3.32Benign0.21Tolerated0.08640.50120-13.316.06
c.1940G>C
G647A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G647A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, FoldX, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome. Predictions that are inconclusive are Rosetta, Foldetta, and premPS. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Benign, and Foldetta as Uncertain. Taken together, the overwhelming majority of evidence indicates a benign effect for G647A, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.048328Structured0.325524Uncertain0.9360.3560.000-0.266Likely Benign0.078Likely BenignLikely Benign-0.18Likely Benign0.0-0.99Ambiguous-0.59Ambiguous-0.69Ambiguous0.037Likely Benign0.48Neutral0.000Benign0.002Benign3.55Benign0.81Tolerated0.35580.4136102.214.03
c.26A>T
H9L
2D
AIThe SynGAP1 missense variant H9L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.486429Structured0.528099Binding0.3940.9160.750-2.603Likely Benign0.135Likely BenignLikely Benign0.151Likely Benign0.48Neutral0.024Benign0.002Benign4.25Benign0.00Affected0.12550.6285-2-37.0-23.98
c.28C>G
R10G
2D
AIThe SynGAP1 missense variant R10G is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized scores the variant as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” No Foldetta stability prediction is available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.513657Binding0.3300.9150.625-3.931Likely Benign0.124Likely BenignLikely Benign0.175Likely Benign0.48Neutral0.058Benign0.009Benign4.15Benign0.00Affected0.37960.4015-3-24.1-99.14
c.1985A>G
Q662R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q662R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that assess sequence conservation, structural impact, or functional effect all converge on a benign outcome: SIFT, PolyPhen‑2 (HumDiv and HumVar), REVEL, PROVEAN, FATHMM, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, premPS, FoldX, and Rosetta all predict benign. No tool in the dataset indicates pathogenicity. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also predicts benign. Thus, based on the available predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.046336Structured0.103446Uncertain0.9320.3230.000-6.678Likely Benign0.300Likely BenignLikely Benign-0.41Likely Benign0.00.10Likely Benign-0.16Likely Benign-0.42Likely Benign0.159Likely Benign0.49Neutral0.428Benign0.095Benign3.48Benign1.00Tolerated0.20230.139111-1.028.06
c.3919C>G
P1307A
2D
AIThe SynGAP1 missense variant P1307A is catalogued in gnomAD (ID 6‑33451793‑C‑G) but has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the substitution as tolerated or benign. No tool in the dataset predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as likely benign. Foldetta, a protein‑folding stability predictor, was not available for this variant. Overall, the consensus of all available predictions is benign, and this is consistent with the absence of a ClinVar pathogenic classification. Based on the consensus of all predictions, the variant is most likely benign, and this does not contradict ClinVar status, which has no pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.798249Disordered0.913511Binding0.4910.9010.8756-33451793-C-G16.20e-7-4.042Likely Benign0.078Likely BenignLikely Benign0.064Likely Benign0.49Neutral0.003Benign0.006Benign3.11Benign1.00Tolerated3.7750.37470.4451-113.4-26.04
c.898T>A
S300T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S300T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only FATHMM indicates a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign; the SGM‑Consensus (3 benign vs. 1 pathogenic) is benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also predicts benign. No prediction or stability result is inconclusive. Overall, the evidence overwhelmingly supports a benign classification, and this conclusion does not contradict the absence of a ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.356642Structured0.256848Uncertain0.7420.2800.375-4.648Likely Benign0.069Likely BenignLikely Benign0.85Ambiguous0.1-0.30Likely Benign0.28Likely Benign-0.33Likely Benign0.056Likely Benign0.50Neutral0.003Benign0.002Benign1.94Pathogenic0.85Tolerated0.14090.6428110.114.03
c.1918A>G
T640A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T640A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN, REVEL, FoldX, premPS, polyPhen‑2 (HumDiv and HumVar), and SIFT all score the substitution as benign. No tool predicts pathogenicity; only Rosetta yields an uncertain result. High‑accuracy assessments corroborate this benign trend: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is labeled likely benign, while Foldetta (combining FoldX‑MD and Rosetta outputs) remains uncertain. Taken together, the evidence overwhelmingly supports a benign classification for T640A, and this conclusion does not contradict any ClinVar annotation (none).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.066181Structured0.137043Uncertain0.8930.2840.000-3.068Likely Benign0.074Likely BenignLikely Benign0.14Likely Benign0.10.93Ambiguous0.54Ambiguous-0.17Likely Benign0.078Likely Benign0.51Neutral0.009Benign0.001Benign3.51Benign0.42Tolerated0.38340.3202102.5-30.03
c.1919C>A
T640N
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T640N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, premPS, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as tolerated or benign. Only the protein‑stability predictors FoldX and Rosetta returned uncertain results, which are treated as unavailable evidence. High‑accuracy assessments corroborate the benign prediction: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is benign; and Foldetta, which integrates FoldX‑MD and Rosetta outputs, also reports a benign effect. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.066181Structured0.137043Uncertain0.8930.2840.000-4.258Likely Benign0.107Likely BenignLikely Benign-0.50Ambiguous0.20.53Ambiguous0.02Likely Benign0.03Likely Benign0.097Likely Benign0.51Neutral0.229Benign0.084Benign3.45Benign0.25Tolerated0.15180.407900-2.813.00
c.3131C>A
P1044Q
2D
AIThe SynGAP1 missense variant P1044Q is not reported in ClinVar and is absent from gnomAD. All evaluated in‑silico predictors—REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods likewise support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.952126Binding0.3310.8550.750-4.439Likely Benign0.091Likely BenignLikely Benign0.338Likely Benign0.51Neutral0.004Benign0.015Benign5.43Benign0.45Tolerated0.15440.55910-1-1.931.01
c.3859C>G
P1287A
2D
AIThe SynGAP1 missense variant P1287A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign classification, and this conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.827927Disordered0.813701Binding0.5380.7770.750-3.064Likely Benign0.065Likely BenignLikely Benign0.090Likely Benign0.51Neutral0.001Benign0.002Benign2.91Benign0.57Tolerated0.28850.32221-13.4-26.04
c.3964G>A
A1322T
2D
AIThe SynGAP1 missense variant A1322T is catalogued in gnomAD (ID 6‑33451838‑G‑A) but has no ClinVar entry. All available in silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool reports a pathogenic outcome. High‑accuracy assessments concur: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method, has no reported result for this variant. Overall, the evidence strongly supports a benign classification, and this is consistent with the absence of a ClinVar pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.921040Binding0.4660.8250.8756-33451838-G-A-4.940Likely Benign0.077Likely BenignLikely Benign0.079Likely Benign0.51Neutral0.000Benign0.000Benign4.20Benign0.27Tolerated3.7750.19720.758201-2.530.03
c.2952G>C
K984N
2D
AIThe SynGAP1 missense variant K984N is catalogued in gnomAD (6‑33443504‑G‑C) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, and FATHMM, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. High‑accuracy assessments are mixed: AlphaMissense‑Optimized rates the variant as uncertain, SGM‑Consensus (a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) labels it “Likely Benign,” and Foldetta (which integrates FoldX‑MD and Rosetta outputs) has no available result for this residue. Overall, the balance of evidence leans toward a benign effect, with no pathogenic ClinVar classification to contradict this inference.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.951648Binding0.2880.8950.7506-33443504-G-C16.20e-7-3.020Likely Benign0.955Likely PathogenicAmbiguous0.091Likely Benign0.52Neutral0.951Possibly Damaging0.637Possibly Damaging2.89Benign0.00Affected4.3210.41380.1677010.4-14.07
c.2952G>T
K984N
2D
AISynGAP1 missense variant K984N has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict pathogenicity are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments are mixed: AlphaMissense‑Optimized is Uncertain, SGM‑Consensus is Likely Benign, and Foldetta results are unavailable. Overall, the balance of evidence leans toward a benign interpretation, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.951648Binding0.2880.8950.750-3.020Likely Benign0.955Likely PathogenicAmbiguous0.091Likely Benign0.52Neutral0.951Possibly Damaging0.637Possibly Damaging2.89Benign0.00Affected4.3210.41380.1677010.4-14.07
c.3139T>C
S1047P
2D
AIThe SynGAP1 missense variant S1047P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only SIFT indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also classifies the variant as likely benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions points to a benign impact, and this is consistent with the lack of any ClinVar pathogenic annotation. Thus, the variant is most likely benign, and this does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.963420Disordered0.933764Binding0.4090.9090.750-2.415Likely Benign0.076Likely BenignLikely Benign0.064Likely Benign0.52Neutral0.001Benign0.001Benign2.62Benign0.03Affected0.23730.56561-1-0.810.04
c.3221A>C
Q1074P
2D
AIThe SynGAP1 missense variant Q1074P is listed in gnomAD (ID 6‑33443773‑A‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign or tolerated. Only polyPhen‑2 HumDiv flags it as pathogenic, creating a single outlier. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.987006Binding0.3390.8970.7506-33443773-A-C16.23e-7-4.259Likely Benign0.083Likely BenignLikely Benign0.188Likely Benign0.52Neutral0.925Possibly Damaging0.432Benign2.66Benign0.13Tolerated3.7750.20460.5784-101.9-31.01
c.3845A>C
E1282A
2D
AIThe SynGAP1 missense variant E1282A is not reported in ClinVar and is absent from gnomAD. Across the available in‑silico predictors, every tool examined—REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—consistently classifies the substitution as benign. No pathogenic predictions are present. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts a benign effect, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Overall, the computational evidence overwhelmingly supports a benign impact, and this conclusion does not contradict any ClinVar status, as none exists for E1282A.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.817364Binding0.4650.7250.875-1.980Likely Benign0.097Likely BenignLikely Benign0.118Likely Benign0.52Neutral0.026Benign0.018Benign2.94Benign0.38Tolerated0.34110.53580-15.3-58.04
c.3869G>A
R1290K
2D
AIThe SynGAP1 missense variant R1290K is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective predictions strongly suggest that the variant is most likely benign, and this conclusion is consistent with the lack of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.844138Binding0.5670.7950.625-3.749Likely Benign0.145Likely BenignLikely Benign0.037Likely Benign0.52Neutral0.004Benign0.006Benign3.09Benign1.00Tolerated0.33420.3113320.6-28.01
c.578C>T
A193V
2D
AIThe SynGAP1 A193V missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign (three benign votes versus one pathogenic). High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.429200Structured0.428386Uncertain0.3100.5770.125-3.548Likely Benign0.744Likely PathogenicLikely Benign0.177Likely Benign0.52Neutral0.767Possibly Damaging0.344Benign4.30Benign1.00Tolerated0.11690.6775002.428.05
c.1594A>T
T532S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T532S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only FATHMM predicts a pathogenic outcome. When high‑accuracy methods are considered separately, AlphaMissense‑Optimized remains benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is “Likely Benign,” and Foldetta (combining FoldX‑MD and Rosetta outputs) also reports a benign effect. No prediction or stability result is missing or inconclusive. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.275179Structured0.021478Uncertain0.8890.3850.0000.616Likely Benign0.062Likely BenignLikely Benign0.15Likely Benign0.1-0.23Likely Benign-0.04Likely Benign-0.10Likely Benign0.160Likely Benign0.53Neutral0.005Benign0.013Benign-1.22Pathogenic1.00Tolerated0.29880.286611-0.1-14.03
c.1109G>C
G370A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G370A is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Pathogenic predictions come from FoldX, Foldetta, and FATHMM, while Rosetta remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus also indicating a likely benign outcome, and Foldetta suggesting a pathogenic impact via combined FoldX‑MD and Rosetta stability analysis. Overall, the majority of evidence points to a benign effect, with only a minority of tools predicting pathogenicity. There is no ClinVar entry to contradict this assessment, so the variant is most likely benign based on current computational predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.461924Structured0.434325Uncertain0.3590.7200.500-3.334Likely Benign0.080Likely BenignLikely Benign2.44Destabilizing1.31.62Ambiguous2.03Destabilizing-0.14Likely Benign0.304Likely Benign0.54Neutral0.000Benign0.000Benign1.33Pathogenic0.79Tolerated0.38830.5247102.214.03
c.305T>C
L102S
2D
AIThe SynGAP1 missense variant L102S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus likewise indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign impact for the L102S variant, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.696014Binding0.3570.8850.625-3.260Likely Benign0.105Likely BenignLikely Benign0.174Likely Benign0.54Neutral0.984Probably Damaging0.969Probably Damaging4.18Benign0.00Affected0.27850.1752-3-2-4.6-26.08
c.694G>T
A232S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A232S is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Across the evaluated in‑silico predictors, all tools except AlphaMissense‑Default converge on a benign interpretation: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all predict benign. AlphaMissense‑Default is uncertain, while AlphaMissense‑Optimized predicts benign. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign; and Foldetta (combining FoldX‑MD and Rosetta outputs) is benign. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.254060Structured0.307228Uncertain0.8780.3050.000-3.264Likely Benign0.344AmbiguousLikely Benign0.23Likely Benign0.1-0.23Likely Benign0.00Likely Benign-0.20Likely Benign0.378Likely Benign0.54Neutral0.057Benign0.025Benign5.95Benign1.00Tolerated0.27770.530011-2.616.00
c.1434A>C
E478D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant E478D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). No tool predicts a pathogenic outcome; the only inconclusive result is from Rosetta, which is treated as unavailable. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, SGM‑Consensus (majority vote) indicates likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts benign. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.264545Structured0.414660Uncertain0.7870.2490.000-1.004Likely Benign0.085Likely BenignLikely Benign-0.04Likely Benign0.0-0.65Ambiguous-0.35Likely Benign-0.28Likely Benign0.175Likely Benign0.55Neutral0.000Benign0.001Benign3.53Benign0.70Tolerated0.17680.3315320.0-14.03
c.1434A>T
E478D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant E478D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). No tool predicts a pathogenic outcome; the only inconclusive result is from Rosetta, which is treated as unavailable. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, SGM‑Consensus is “Likely Benign,” and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts benign. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.264545Structured0.414660Uncertain0.7870.2490.000-1.004Likely Benign0.085Likely BenignLikely Benign-0.04Likely Benign0.0-0.65Ambiguous-0.35Likely Benign-0.28Likely Benign0.175Likely Benign0.55Neutral0.000Benign0.001Benign3.53Benign0.70Tolerated0.17680.3315320.0-14.03
c.1672C>T
H558Y
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 H558Y missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, Rosetta, Foldetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while FoldX, premPS, and ESM1b are uncertain. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign result; and Foldetta also predicts benign. No prediction or folding stability result is missing or inconclusive. Overall, the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.033407Structured0.011039Uncertain0.8970.2000.000-7.208In-Between0.187Likely BenignLikely Benign-0.58Ambiguous0.0-0.36Likely Benign-0.47Likely Benign-0.56Ambiguous0.359Likely Benign0.55Neutral0.019Benign0.013Benign-1.24Pathogenic1.00Tolerated0.09380.2363021.926.03
c.3187G>C
G1063R
2D
AIThe SynGAP1 missense variant G1063R is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the collective evidence strongly supports a benign classification, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975134Disordered0.945784Binding0.3940.9130.875-5.711Likely Benign0.391AmbiguousLikely Benign0.078Likely Benign0.55Neutral0.411Benign0.114Benign4.28Benign0.09Tolerated0.10370.5133-3-2-4.199.14
c.3227T>C
L1076S
2D
AIThe SynGAP1 missense variant L1076S is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, and ESM1b, whereas polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Default all predict a pathogenic outcome. High‑accuracy assessments are less decisive: AlphaMissense‑Optimized is uncertain; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (two benign vs. two pathogenic votes); and Foldetta results are unavailable. Consequently, the evidence is evenly split between benign and pathogenic predictions. The variant is therefore most likely of uncertain significance, and this assessment does not contradict the absence of a ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.922952Disordered0.989617Binding0.3010.8920.750-2.975Likely Benign0.913Likely PathogenicAmbiguous0.225Likely Benign0.55Neutral0.999Probably Damaging0.983Probably Damaging2.43Pathogenic0.75Tolerated0.30450.1178-3-2-4.6-26.08
c.3890G>A
R1297K
2D
AIThe SynGAP1 missense variant R1297K is catalogued in gnomAD (ID 6‑33451764‑G‑A) but has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the substitution as tolerated or benign. Grouping by consensus, all listed predictors fall into the benign category, with no tool reporting a pathogenic outcome. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign classification. Foldetta stability analysis is unavailable for this variant. Consequently, the aggregate evidence strongly supports a benign interpretation, and this assessment does not conflict with the absence of a ClinVar pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.859585Disordered0.895222Binding0.5110.8170.6256-33451764-G-A16.20e-7-3.780Likely Benign0.114Likely BenignLikely Benign0.074Likely Benign0.55Neutral0.000Benign0.004Benign2.80Benign1.00Tolerated3.7750.41090.2801230.6-28.01
c.3898C>G
P1300A
2D
AIThe SynGAP1 missense variant P1300A is reported in gnomAD (ID 6‑33451772‑C‑G) and has no ClinVar entry. Across the evaluated in‑silico tools, every predictor classifies the substitution as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. No tool predicts pathogenicity, so the pathogenic‑prediction group is empty. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized indicates a benign effect, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Based on the unanimous benign predictions and the absence of any pathogenic signal, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.885826Binding0.4000.8340.8756-33451772-C-G21.24e-6-3.802Likely Benign0.073Likely BenignLikely Benign0.065Likely Benign0.55Neutral0.008Benign0.006Benign3.23Benign1.00Tolerated3.7750.33420.3744-113.4-26.04
c.610T>A
S204T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S204T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all indicate benign or likely benign. Only polyPhen‑2 HumDiv predicts a pathogenic effect. Stability‑based methods (FoldX, Rosetta, Foldetta, premPS) are inconclusive, providing no definitive evidence. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as likely benign, and Foldetta as uncertain. Taken together, the majority of reliable predictors classify S204T as benign, and this conclusion does not contradict the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.268042Structured0.420667Uncertain0.8160.4050.125-4.164Likely Benign0.167Likely BenignLikely Benign0.75Ambiguous0.11.19Ambiguous0.97Ambiguous-0.52Ambiguous0.104Likely Benign0.55Neutral0.462Possibly Damaging0.173Benign4.19Benign1.00Tolerated0.08570.5063110.114.03
c.751A>C
K251Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant K251Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that uniformly indicate a benign effect include REVEL, FoldX, Rosetta, Foldetta, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv and polyPhen‑2 HumVar, while premPS and AlphaMissense‑Default are inconclusive. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as benign. Taken together, the majority of evidence supports a benign classification for K251Q, and this conclusion does not contradict the absence of a ClinVar entry. Based on the aggregate predictions, K251Q is most likely benign, and this is consistent with its absence from ClinVar.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.447574Structured0.226632Uncertain0.7580.3120.125-5.869Likely Benign0.362AmbiguousLikely Benign0.36Likely Benign0.10.42Likely Benign0.39Likely Benign-0.62Ambiguous0.465Likely Benign0.55Neutral0.997Probably Damaging0.879Possibly Damaging5.86Benign0.63Tolerated0.44660.1085110.4-0.04
c.61T>A
F21I
2D
AIThe SynGAP1 missense variant F21I is listed in gnomAD (ID 6‑33420325‑T‑A) but has no ClinVar entry. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also benign; Foldetta results are unavailable. Taken together, the majority of evidence points to a benign effect. Thus, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.443284Uncertain0.3690.8970.5006-33420325-T-A-3.678Likely Benign0.678Likely PathogenicLikely Benign0.141Likely Benign0.56Neutral0.462Possibly Damaging0.307Benign4.29Benign0.00Affected4.3210.27030.2469011.7-34.02
c.1054A>T
T352S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T352S is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools largely agree on a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only FATHMM predicts a pathogenic outcome. The high‑accuracy consensus methods reinforce the benign assessment: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also reports a benign effect. No predictions or stability results are missing or inconclusive. Based on the overwhelming agreement among the majority of tools and the high‑accuracy methods, the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.137348Structured0.367886Uncertain0.9260.3290.000-1.670Likely Benign0.062Likely BenignLikely Benign-0.09Likely Benign0.00.26Likely Benign0.09Likely Benign-0.01Likely Benign0.098Likely Benign0.57Neutral0.002Benign0.002Benign1.81Pathogenic1.00Tolerated0.35830.488011-0.1-14.03
c.1055C>G
T352S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T352S is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools largely agree on a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only FATHMM predicts a pathogenic outcome. The high‑accuracy consensus methods reinforce the benign assessment: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also reports a benign effect. No predictions or stability results are missing or inconclusive. Based on the overwhelming agreement among the majority of tools and the high‑accuracy methods, the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.137348Structured0.367886Uncertain0.9260.3290.000-1.670Likely Benign0.062Likely BenignLikely Benign-0.09Likely Benign0.00.26Likely Benign0.09Likely Benign-0.01Likely Benign0.104Likely Benign0.57Neutral0.002Benign0.002Benign1.81Pathogenic1.00Tolerated0.35830.488011-0.1-14.03
c.1963C>A
L655M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L655M is not reported in ClinVar and is absent from gnomAD. All available in‑silico predictors classify the change as benign: REVEL, FoldX, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). No tool predicts pathogenicity. High‑accuracy assessments are consistent: AlphaMissense‑Optimized predicts benign; the SGM Consensus indicates “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also predicts benign. Based on the unanimous benign predictions and the absence of any pathogenic calls, the variant is most likely benign, and this conclusion does not contradict the ClinVar status (which has no entry).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.015344Structured0.268808Uncertain0.9610.2740.000-3.077Likely Benign0.083Likely BenignLikely Benign0.21Likely Benign0.00.25Likely Benign0.23Likely Benign-0.22Likely Benign0.076Likely Benign0.58Neutral0.048Benign0.037Benign3.43Benign0.18Tolerated0.09790.325242-1.918.03
c.2821C>T
P941S
2D
AIThe SynGAP1 missense variant P941S is reported in gnomAD (ID 6‑33443373‑C‑T) but has no ClinVar entry. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, which evaluates protein‑folding stability via FoldX‑MD and Rosetta, has no available result for this variant. Overall, the consensus of all available predictions indicates that P941S is most likely benign, and this assessment does not contradict any ClinVar status (none).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.874069Disordered0.900790Binding0.4030.9060.6256-33443373-C-T16.20e-7-5.099Likely Benign0.062Likely BenignLikely Benign0.039Likely Benign0.58Neutral0.036Benign0.039Benign3.05Benign0.95Tolerated4.3240.27590.5576-110.8-10.04
c.729T>G
I243M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I243M has no ClinVar entry (ClinVar status: not reported) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign”; and Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, also predicts a benign effect. Overall, the consensus of the majority of tools, including the high‑accuracy methods, indicates that the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.363090Structured0.344471Uncertain0.8420.3470.000-4.305Likely Benign0.175Likely BenignLikely Benign0.09Likely Benign0.10.16Likely Benign0.13Likely Benign-0.01Likely Benign0.474Likely Benign0.58Neutral0.985Probably Damaging0.798Possibly Damaging5.61Benign0.94Tolerated0.05530.220021-2.618.03
c.367G>A
A123T
2D
AIThe SynGAP1 missense variant A123T is reported as “Likely Benign” in ClinVar and is not present in gnomAD. Prediction tools that assess functional impact all converge on a benign outcome: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool in the dataset predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign effect. Foldetta results are unavailable. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.521092Disordered0.689505Binding0.3240.8860.750-3.999Likely Benign0.077Likely BenignLikely Benign0.117Likely Benign0.59Neutral0.004Benign0.001Benign4.29Benign0.52Tolerated0.19120.710910-2.530.03
c.2149C>A
L717I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L717I is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Only two tools—polyPhen‑2 HumDiv and HumVar—predict a pathogenic outcome, while premPS is inconclusive. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts Benign; the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign; and Foldetta (combining FoldX‑MD and Rosetta outputs) reports Benign. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.239899Structured0.429342Uncertain0.9690.3970.000-4.836Likely Benign0.168Likely BenignLikely Benign0.27Likely Benign0.00.33Likely Benign0.30Likely Benign-0.73Ambiguous0.182Likely Benign0.60Neutral0.997Probably Damaging0.989Probably Damaging3.43Benign1.00Tolerated0.07120.2570220.70.00
c.1964T>A
L655Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L655Q is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, FoldX, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all indicate benign or likely benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity, while Rosetta remains inconclusive. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign, the SGM‑Consensus is likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts benign stability. Overall, the majority of evidence supports a benign impact for L655Q, which does not contradict the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.015344Structured0.268808Uncertain0.9610.2740.000Uncertain 1-5.278Likely Benign0.144Likely BenignLikely Benign-0.01Likely Benign0.00.69Ambiguous0.34Likely Benign-0.15Likely Benign0.139Likely Benign0.61Neutral0.955Possibly Damaging0.602Possibly Damaging3.59Benign0.65Tolerated3.39240.12480.0972-2-2-7.314.97229.9-8.60.00.00.40.0XPotentially BenignThe iso-butyl side chain of Leu655, located on the surface of an α helix (res. Ser641-Glu666), is not involved in any interactions in the WT simulations. In the variant simulations, the carboxamide side chain of Gln655 dynamically interacts with neighboring residues (e.g., Glu651, Glu656, Arg544) on the protein surface, with no negative structural effects.
c.3043A>T
T1015S
2D
AIThe SynGAP1 missense variant T1015S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.928486Binding0.2950.8230.625-2.561Likely Benign0.066Likely BenignLikely Benign0.090Likely Benign0.61Neutral0.001Benign0.002Benign2.70Benign0.86Tolerated0.35450.423211-0.1-14.03
c.3044C>G
T1015S
2D
AIThe SynGAP1 missense variant T1015S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.928486Binding0.2950.8230.625-2.561Likely Benign0.066Likely BenignLikely Benign0.040Likely Benign0.61Neutral0.001Benign0.002Benign2.70Benign0.86Tolerated0.35450.423211-0.1-14.03
c.1018G>A
A340T
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant A340T is reported in gnomAD (ID 6‑33437923‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus all classify the change as benign or likely benign. Only two tools predict pathogenicity—polyPhen‑2 HumDiv and FATHMM—while stability‑based methods (FoldX, Rosetta, premPS, Foldetta) return uncertain or inconclusive results. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates likely benign, and Foldetta provides no definitive stability change. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.390993Structured0.410781Uncertain0.5580.4850.2506-33437923-G-A-3.286Likely Benign0.086Likely BenignLikely Benign0.84Ambiguous0.20.96Ambiguous0.90Ambiguous-0.54Ambiguous0.105Likely Benign0.62Neutral0.454Possibly Damaging0.192Benign1.93Pathogenic0.47Tolerated3.42130.17400.729701-2.530.03
c.1492A>C
M498L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M498L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, FoldX, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Only FATHMM predicts a pathogenic outcome, while Rosetta, Foldetta, and premPS are inconclusive. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, the SGM‑Consensus as Likely Benign, and Foldetta as Uncertain. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation and gnomAD presence, so there is no contradiction with existing clinical databases.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.092881Structured0.399612Uncertain0.9320.1580.0002.556Likely Benign0.072Likely BenignLikely Benign-0.23Likely Benign0.1-0.89Ambiguous-0.56Ambiguous-0.53Ambiguous0.271Likely Benign0.62Neutral0.000Benign0.000Benign-1.24Pathogenic0.92Tolerated0.13190.3551421.9-18.03
c.1492A>T
M498L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M498L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, FoldX, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) all predict benign or likely benign. Only FATHMM predicts a pathogenic outcome, while Rosetta, Foldetta, and premPS are inconclusive. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as likely benign, and Foldetta as uncertain. Overall, the majority of evidence supports a benign classification, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.092881Structured0.399612Uncertain0.9320.1580.0002.556Likely Benign0.072Likely BenignLikely Benign-0.23Likely Benign0.1-0.89Ambiguous-0.56Ambiguous-0.53Ambiguous0.271Likely Benign0.62Neutral0.000Benign0.000Benign-1.24Pathogenic0.92Tolerated0.13190.3551421.9-18.03
c.4018A>T
T1340S
2D
AIThe SynGAP1 missense variant T1340S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Overall, the variant is most likely benign based on the available predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.977899Binding0.4440.6970.750-2.698Likely Benign0.091Likely BenignLikely Benign0.116Likely Benign0.62Neutral0.000Benign0.001Benign4.87Benign1.00Tolerated0.34360.452111-0.1-14.03
c.4019C>G
T1340S
2D
AIThe SynGAP1 missense variant T1340S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Overall, the variant is most likely benign based on the available predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.977899Binding0.4440.6970.750-2.698Likely Benign0.091Likely BenignLikely Benign0.083Likely Benign0.62Neutral0.000Benign0.001Benign4.87Benign1.00Tolerated0.34360.452111-0.1-14.03
c.1039A>T
T347S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T347S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only FATHMM predicts a pathogenic outcome. Stability‑based methods (FoldX, Rosetta, Foldetta) are inconclusive, so they provide no evidence for or against pathogenicity. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as likely benign, and Foldetta as uncertain. Overall, the majority of reliable predictors indicate a benign effect, and there is no ClinVar annotation to contradict this assessment. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.268042Structured0.349915Uncertain0.9510.4340.000-3.342Likely Benign0.090Likely BenignLikely Benign0.65Ambiguous0.10.82Ambiguous0.74Ambiguous-0.10Likely Benign0.104Likely Benign0.63Neutral0.002Benign0.001Benign1.75Pathogenic0.86Tolerated0.32050.470711-0.1-14.03
c.1040C>G
T347S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T347S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only FATHMM predicts a pathogenic outcome. Stability‑based methods (FoldX, Rosetta, Foldetta) are inconclusive, so they provide no evidence for or against pathogenicity. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as likely benign, and Foldetta as uncertain. Overall, the majority of reliable predictors indicate a benign effect, and there is no ClinVar annotation to contradict this assessment. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.268042Structured0.349915Uncertain0.9510.4340.000-3.342Likely Benign0.090Likely BenignLikely Benign0.65Ambiguous0.10.82Ambiguous0.74Ambiguous-0.10Likely Benign0.054Likely Benign0.63Neutral0.002Benign0.001Benign1.75Pathogenic0.86Tolerated0.32050.470711-0.1-14.03
c.653T>A
F218Y
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant F218Y is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). All available in silico predictors classify the substitution as benign: REVEL, FoldX, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all indicate a benign effect. The high‑accuracy folding‑stability tool Foldetta, which integrates FoldX‑MD and Rosetta outputs, also predicts a benign impact. No tool predicts pathogenicity, and no contradictory evidence exists in ClinVar. **Based on the consensus of all predictions, the variant is most likely benign, and this assessment does not conflict with ClinVar status.**

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.281712Structured0.408725Uncertain0.8480.2720.000-3.596Likely Benign0.104Likely BenignLikely Benign0.26Likely Benign0.1-0.40Likely Benign-0.07Likely Benign-0.44Likely Benign0.229Likely Benign0.63Neutral0.001Benign0.002Benign5.95Benign0.52Tolerated0.15320.272573-4.116.00
c.2819G>C
G940A
2D
AIThe SynGAP1 missense variant G940A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.920635Binding0.3830.9020.625-5.356Likely Benign0.077Likely BenignLikely Benign0.163Likely Benign0.64Neutral0.004Benign0.012Benign2.85Benign0.89Tolerated0.36270.4831102.214.03
c.61T>G
F21V
2D
AIThe SynGAP1 missense variant F21V is listed in gnomAD (ID 6‑33420325‑T‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.443284Uncertain0.3690.8970.5006-33420325-T-G-2.823Likely Benign0.563AmbiguousLikely Benign0.224Likely Benign0.64Neutral0.462Possibly Damaging0.307Benign4.44Benign0.00Affected4.3210.25360.2497-1-11.4-48.04
c.1939G>A
G647S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G647S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, FoldX, Foldetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the only inconclusive results come from Rosetta and premPS, which are treated as unavailable. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts benign stability. Overall, the evidence strongly favors a benign classification, and this is consistent with its absence from ClinVar. The variant is most likely benign, and this is consistent with its absence from ClinVar.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.048328Structured0.325524Uncertain0.9360.3560.000-2.175Likely Benign0.082Likely BenignLikely Benign0.05Likely Benign0.1-0.75Ambiguous-0.35Likely Benign-0.56Ambiguous0.037Likely Benign0.65Neutral0.002Benign0.004Benign3.48Benign0.89Tolerated0.24090.395910-0.430.03
c.610T>G
S204A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S204A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the only inconclusive results come from Rosetta, Foldetta, and premPS, which are treated as unavailable evidence. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Benign, and Foldetta as Uncertain. Overall, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.268042Structured0.420667Uncertain0.8160.4050.125-3.330Likely Benign0.084Likely BenignLikely Benign-0.09Likely Benign0.0-1.17Ambiguous-0.63Ambiguous-0.83Ambiguous0.091Likely Benign0.65Neutral0.004Benign0.004Benign4.28Benign0.27Tolerated0.37060.3495112.6-16.00
c.104T>G
V35G
2D
AIThe SynGAP1 missense variant V35G is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is benign. High‑accuracy methods give the following results: AlphaMissense‑Optimized predicts benign; the SGM Consensus also predicts benign; Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status because the variant is not currently catalogued in ClinVar.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.613573Disordered0.434838Uncertain0.3600.8510.375-3.614Likely Benign0.109Likely BenignLikely Benign0.143Likely Benign0.66Neutral0.693Possibly Damaging0.824Possibly Damaging4.41Benign0.00Affected0.15140.2618-1-3-4.6-42.08
c.3706C>G
Q1236E
2D
AIThe SynGAP1 missense variant Q1236E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence supports a benign classification for Q1236E, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.680603Disordered0.567914Binding0.8830.5370.125-0.371Likely Benign0.146Likely BenignLikely Benign0.263Likely Benign0.66Neutral0.985Probably Damaging0.981Probably Damaging3.18Benign1.00Tolerated0.09850.1130220.00.98
c.3901C>G
P1301A
2D
AIThe SynGAP1 missense variant P1301A is catalogued in gnomAD (ID 6‑33451775‑C‑G) but has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the substitution as tolerated or benign. No tool in the dataset predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as likely benign. Foldetta, a protein‑folding stability predictor, was not available for this residue. Overall, the consensus of all available predictions is benign, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.728858Disordered0.885064Binding0.4470.8410.8756-33451775-C-G16.20e-7-4.290Likely Benign0.055Likely BenignLikely Benign0.088Likely Benign0.66Neutral0.003Benign0.012Benign3.05Benign0.88Tolerated3.7750.28500.3087-113.4-26.04
c.651G>C
E217D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant E217D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all classify the change as benign. The only inconclusive result comes from AlphaMissense‑Default, which is listed as uncertain. High‑accuracy assessments corroborate this benign profile: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign,” and Foldetta (combining FoldX‑MD and Rosetta outputs) also reports a benign outcome. No pathogenic predictions are present. Therefore, based on the available computational evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.278302Structured0.404912Uncertain0.8230.2840.000-2.268Likely Benign0.453AmbiguousLikely Benign0.24Likely Benign0.3-0.07Likely Benign0.09Likely Benign-0.34Likely Benign0.276Likely Benign0.66Neutral0.014Benign0.007Benign5.85Benign0.85Tolerated3.41130.20660.5976230.0-14.03
c.651G>T
E217D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant E217D is present in gnomAD (6‑33435293‑G‑T) but has no ClinVar entry. Functional prediction tools uniformly classify it as benign: REVEL, FoldX, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and Foldetta all report benign or benign‑like outcomes. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized indicates benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also reports benign. AlphaMissense‑Default remains uncertain and is treated as unavailable. Overall, the evidence strongly supports a benign effect for E217D, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.278302Structured0.404912Uncertain0.8230.2840.0006-33435293-G-T16.20e-7-2.268Likely Benign0.453AmbiguousLikely Benign0.24Likely Benign0.3-0.07Likely Benign0.09Likely Benign-0.34Likely Benign0.276Likely Benign0.66Neutral0.014Benign0.007Benign5.85Benign0.85Tolerated3.41130.20660.5976230.0-14.03
c.1609G>C
A537P
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A537P is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are FATHMM and Rosetta; FoldX and Foldetta are inconclusive. The high‑accuracy consensus (SGM‑Consensus) derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN indicates a likely benign outcome, while AlphaMissense‑Optimized also predicts benign. Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, is uncertain. Overall, the majority of evidence points to a benign impact for A537P, and this assessment does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.116183Structured0.037313Uncertain0.9280.3620.0000.404Likely Benign0.102Likely BenignLikely Benign-0.61Ambiguous0.62.43Destabilizing0.91Ambiguous-0.18Likely Benign0.218Likely Benign0.67Neutral0.020Benign0.022Benign-1.29Pathogenic0.35Tolerated0.21520.38071-1-3.426.04
c.2555G>A
G852D
2D
AIThe SynGAP1 missense variant G852D is catalogued in gnomAD (ID 6‑33443107‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign or tolerated outcomes, while the single pathogenic signal comes from SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign likelihood; Foldetta results are not available. Overall, the preponderance of evidence points to a benign impact for G852D, and this conclusion is not contradicted by any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.506063Binding0.2760.8160.6256-33443107-G-A16.20e-7-5.588Likely Benign0.203Likely BenignLikely Benign0.154Likely Benign0.67Neutral0.001Benign0.005Benign4.18Benign0.01Affected3.7750.18550.2175-11-3.158.04
c.3344T>G
I1115S
2D
AIThe SynGAP1 missense variant I1115S is catalogued in gnomAD (ID 6‑33443896‑T‑G) but has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the variant as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are unavailable. Overall, the consensus of all available predictions is benign, and this is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.892339Binding0.3080.9120.7506-33443896-T-G-0.579Likely Benign0.073Likely BenignLikely Benign0.128Likely Benign0.67Neutral0.000Benign0.001Benign2.88Benign0.14Tolerated4.3220.29860.1453-2-1-5.3-26.08
c.2426G>C
S809T
2D
AIThe SynGAP1 missense variant S809T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports a likely benign outcome. Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.626927Disordered0.853218Binding0.3300.9070.500-3.865Likely Benign0.091Likely BenignLikely Benign0.076Likely Benign0.68Neutral0.003Benign0.010Benign2.95Benign0.82Tolerated0.14300.6617110.114.03
c.3961C>T
P1321S
2D
AIThe SynGAP1 missense variant P1321S is listed in ClinVar (ID 1806027.0) with an “Uncertain” clinical significance and is present in the gnomAD database (gnomAD ID 6‑33451835‑C‑T). All evaluated in‑silico predictors classify the substitution as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool reports a pathogenic prediction. High‑accuracy assessments corroborate this benign trend: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status is unavailable. Overall, the computational evidence strongly supports a benign effect, which is consistent with the ClinVar “Uncertain” designation rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.827927Disordered0.933505Binding0.4630.8280.875Uncertain 26-33451835-C-T106.46e-6-4.897Likely Benign0.077Likely BenignLikely Benign0.049Likely Benign0.68Neutral0.028Benign0.004Benign4.27Benign0.71Tolerated3.7750.36100.51901-10.8-10.0410.1016/j.ajhg.2020.11.011
c.1528A>C
I510L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I510L is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments—AlphaMissense‑Optimized, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), and Foldetta (combining FoldX‑MD and Rosetta)—all indicate a benign effect. No prediction or folding‑stability result is missing or inconclusive. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.025762Structured0.250630Uncertain0.9450.2730.000-2.362Likely Benign0.116Likely BenignLikely Benign0.31Likely Benign0.2-0.05Likely Benign0.13Likely Benign-1.01Stabilizing0.338Likely Benign0.69Neutral0.016Benign0.130Benign-0.74Pathogenic1.00Tolerated0.08190.246122-0.70.00
c.2611C>A
H871N
2D
AIThe SynGAP1 missense variant H871N is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification—there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.679301Binding0.2790.8580.250-3.303Likely Benign0.046Likely BenignLikely Benign0.100Likely Benign0.69Neutral0.000Benign0.001Benign2.69Benign0.40Tolerated0.16260.250721-0.3-23.04
c.2080G>T
A694S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A694S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree that the substitution is benign: REVEL, FoldX, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. The only inconclusive results come from Rosetta and premPS, which are listed as uncertain and do not influence the overall assessment. High‑accuracy predictors reinforce this view: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) also reports benign. Consequently, the variant is most likely benign, and this prediction is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.127496Structured0.352199Uncertain0.9380.2690.000-0.326Likely Benign0.076Likely BenignLikely Benign0.22Likely Benign0.10.59Ambiguous0.41Likely Benign-0.53Ambiguous0.092Likely Benign0.70Neutral0.013Benign0.021Benign3.57Benign1.00Tolerated0.27250.423111-2.616.00
c.3859C>T
P1287S
2D
AIThe SynGAP1 missense variant P1287S is catalogued in gnomAD (ID 6‑33447907‑C‑T) but has no ClinVar entry. Across the spectrum of in‑silico predictors, every tool listed—REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—consistently scores the variant as benign. No pathogenic predictions are reported. Grouping by agreement, the benign‑predicting tools comprise the entire set, while the pathogenic group is empty. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is assigned).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.827927Disordered0.813701Binding0.5380.7770.7506-33447907-C-T-3.258Likely Benign0.090Likely BenignLikely Benign0.055Likely Benign0.70Neutral0.004Benign0.004Benign2.96Benign0.96Tolerated3.7750.28200.3566-110.8-10.04
c.3965C>A
A1322D
2D
AIThe SynGAP1 missense variant A1322D is catalogued in gnomAD (ID 6‑33451839‑C‑A) but has no ClinVar entry. Across the spectrum of in‑silico predictors, every tool listed—REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—consistently classifies the substitution as benign. No pathogenic predictions are reported. Grouping by consensus, all available tools fall into the benign category, with no tools indicating pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no result for this variant, so its status is unavailable. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.921040Binding0.4660.8250.8756-33451839-C-A-5.744Likely Benign0.284Likely BenignLikely Benign0.092Likely Benign0.70Neutral0.013Benign0.004Benign4.17Benign0.45Tolerated3.7750.22460.3134-20-5.344.01
c.1587C>G
I529M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I529M is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, FoldX, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome; Rosetta is uncertain and therefore treated as unavailable. High‑accuracy assessments—AlphaMissense‑Optimized, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), and Foldetta (combining FoldX‑MD and Rosetta outputs)—all uniformly indicate a benign effect. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.318242Structured0.019545Uncertain0.9010.4030.0001.489Likely Benign0.063Likely BenignLikely Benign0.10Likely Benign0.10.68Ambiguous0.39Likely Benign-0.17Likely Benign0.215Likely Benign0.71Neutral0.035Benign0.063Benign-1.27Pathogenic0.15Tolerated0.06730.287621-2.618.03
c.2791C>G
L931V
2D
AIThe SynGAP1 missense variant L931V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic effect. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for the L931V variant, and this conclusion does not contradict any ClinVar annotation, as none exists for this change.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.549308Disordered0.989212Binding0.3350.8560.375-1.512Likely Benign0.234Likely BenignLikely Benign0.182Likely Benign0.71Neutral0.999Probably Damaging0.994Probably Damaging3.03Benign0.70Tolerated0.16900.3164210.4-14.03
c.3874C>A
L1292I
2D
AIThe SynGAP1 missense variant L1292I is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the evidence strongly supports a benign classification, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.779859Disordered0.882643Binding0.5860.8000.625-5.480Likely Benign0.135Likely BenignLikely Benign0.050Likely Benign0.71Neutral0.002Benign0.006Benign3.23Benign1.00Tolerated0.11010.3323220.70.00
c.3895C>A
L1299I
2D
AIThe SynGAP1 missense variant L1299I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.771762Disordered0.896323Binding0.3980.8320.750-5.264Likely Benign0.116Likely BenignLikely Benign0.396Likely Benign0.71Neutral0.003Benign0.004Benign3.20Benign1.00Tolerated0.10140.3893220.70.00
c.914C>A
T305N
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T305N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as tolerated or benign, and the SGM‑Consensus score is “Likely Benign.” Only FATHMM predicts a pathogenic outcome. Stability‑based methods (FoldX, Rosetta, and the combined Foldetta) return uncertain or inconclusive results. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is also benign, and Foldetta remains uncertain. Overall, the majority of evidence supports a benign impact for T305N, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.359901Structured0.299706Uncertain0.8720.2740.125-3.261Likely Benign0.158Likely BenignLikely Benign1.18Ambiguous0.21.65Ambiguous1.42Ambiguous0.09Likely Benign0.098Likely Benign0.71Neutral0.046Benign0.040Benign2.34Pathogenic0.67Tolerated0.13270.435200-2.813.00
c.1021G>A
G341S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G341S is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, polyPhen‑2 HumVar, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and FATHMM. Predictions that are inconclusive or uncertain are Rosetta, Foldetta, and premPS. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, the SGM‑Consensus as Likely Benign, and Foldetta as Uncertain. Overall, the majority of evidence points to a benign impact for G341S, and this conclusion does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.356642Structured0.431164Uncertain0.7450.4790.250-3.206Likely Benign0.090Likely BenignLikely Benign0.41Likely Benign0.3-1.46Ambiguous-0.53Ambiguous-0.67Ambiguous0.343Likely Benign0.73Neutral0.454Possibly Damaging0.192Benign0.37Pathogenic0.72Tolerated0.24160.421510-0.430.03
c.2507G>A
S836N
2D
AIThe SynGAP1 missense variant S836N is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. The only tools that predict a pathogenic outcome are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this conclusion is consistent with the lack of ClinVar annotation. Thus, the variant is most likely benign and does not contradict any existing ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.525368Disordered0.634582Binding0.2690.8590.250-3.881Likely Benign0.269Likely BenignLikely Benign0.116Likely Benign0.75Neutral0.901Possibly Damaging0.636Possibly Damaging2.89Benign0.85Tolerated0.10530.383111-2.727.03
c.3206A>C
Q1069P
2D
AIThe SynGAP1 missense variant Q1069P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign consensus. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.981477Binding0.3330.9060.875-3.458Likely Benign0.056Likely BenignLikely Benign0.211Likely Benign0.75Neutral0.977Probably Damaging0.722Possibly Damaging2.73Benign1.00Tolerated0.21790.59440-11.9-31.01
c.3749A>G
Q1250R
2D
AIThe SynGAP1 missense variant Q1250R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.759478Disordered0.360484Uncertain0.8810.5540.750-5.183Likely Benign0.230Likely BenignLikely Benign0.148Likely Benign0.76Neutral0.994Probably Damaging0.988Probably Damaging3.09Benign1.00Tolerated0.13300.087411-1.028.06
c.1076C>T
T359I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T359I is reported in gnomAD (variant ID 6‑33437981‑C‑T) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome. Uncertain results are reported for FoldX, Rosetta, Foldetta, and premPS. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Benign, and Foldetta as Uncertain. Overall, the majority of evidence points to a benign effect. There is no ClinVar status to contradict this conclusion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.281712Structured0.414952Uncertain0.9390.4800.2506-33437981-C-T16.22e-7-2.594Likely Benign0.181Likely BenignLikely Benign-0.66Ambiguous0.1-0.64Ambiguous-0.65Ambiguous-0.63Ambiguous0.085Likely Benign0.77Neutral0.070Benign0.006Benign1.80Pathogenic0.23Tolerated3.38240.11230.5921-105.212.05
c.3464T>C
V1155A
2D
AIThe SynGAP1 missense variant V1155A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, SGM‑Consensus as Likely Benign, and Foldetta results are unavailable. Overall, the balance of evidence leans toward a benign interpretation, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.750527Disordered0.855718Binding0.3350.8570.500-2.019Likely Benign0.941Likely PathogenicAmbiguous0.224Likely Benign0.77Neutral0.992Probably Damaging0.989Probably Damaging3.15Benign1.00Tolerated0.30700.185900-2.4-28.05
c.2101C>T
P701S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant P701S (ClinVar ID 2995856.0) is listed as “Uncertain” in ClinVar and is present in gnomAD (ID 6‑33441360‑C‑T). Prediction tools that agree on a benign effect include REVEL, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). No tool in the dataset predicts a pathogenic outcome; all remaining predictions are either benign or uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, the SGM‑Consensus as Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as Uncertain. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which remains uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.074921Structured0.404318Uncertain0.9180.3450.000Uncertain 16-33441360-C-T31.86e-6-4.375Likely Benign0.221Likely BenignLikely Benign1.33Ambiguous0.00.12Likely Benign0.73Ambiguous-0.36Likely Benign0.132Likely Benign0.78Neutral0.044Benign0.025Benign3.48Benign1.00Tolerated3.47100.31490.3782-110.8-10.0410.1016/j.ajhg.2020.11.011
c.3224A>C
Q1075P
2D
AIThe SynGAP1 missense variant Q1075P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only two tools, polyPhen‑2 HumDiv and HumVar, predict a pathogenic outcome. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy methods corroborate this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the consensus of the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.988305Binding0.3540.8940.750-1.854Likely Benign0.086Likely BenignLikely Benign0.175Likely Benign0.78Neutral0.996Probably Damaging0.988Probably Damaging2.68Benign0.28Tolerated0.22880.57410-11.9-31.01
c.3131C>G
P1044R
2D
AIThe SynGAP1 missense variant P1044R is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign classification, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.952126Binding0.3310.8550.750-3.969Likely Benign0.242Likely BenignLikely Benign0.368Likely Benign0.79Neutral0.259Benign0.140Benign5.45Benign1.00Tolerated0.14510.42700-2-2.959.07
c.3955G>T
A1319S
2D
AIThe SynGAP1 missense variant A1319S is catalogued in gnomAD (ID 6‑33451829‑G‑T) but has no ClinVar entry. Functional prediction tools uniformly classify it as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign effects. No tool predicts pathogenicity. Grouping by consensus, all listed predictors fall into the benign category, with no pathogenic predictions to counterbalance. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized indicates benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports a likely benign outcome. Foldetta results are not available for this variant. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.842060Disordered0.960481Binding0.4540.8510.7506-33451829-G-T-4.557Likely Benign0.075Likely BenignLikely Benign0.094Likely Benign0.79Neutral0.174Benign0.112Benign4.17Benign1.00Tolerated3.7750.29570.567611-2.616.00
c.3427A>C
T1143P
2D
AIThe SynGAP1 missense variant T1143P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic effect. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.722918Binding0.2750.8371.000-2.307Likely Benign0.155Likely BenignLikely Benign0.183Likely Benign0.80Neutral0.999Probably Damaging0.966Probably Damaging2.69Benign0.24Tolerated0.18180.41080-1-0.9-3.99
c.3736A>G
K1246E
2D
AIThe SynGAP1 missense variant K1246E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion is consistent with the lack of any ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.750527Disordered0.375382Uncertain0.8870.5640.625-2.052Likely Benign0.305Likely BenignLikely Benign0.127Likely Benign0.80Neutral0.910Possibly Damaging0.630Possibly Damaging2.89Benign1.00Tolerated0.33280.0514010.40.94
c.4021G>T
A1341S
2D
AIThe SynGAP1 missense variant A1341S is listed in ClinVar with an “Uncertain” status and is present in gnomAD (variant ID 6-33451895-G-T). All available in silico predictors agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is benign; Foldetta results are not available. Based on the collective predictions, the variant is most likely benign, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.823549Disordered0.980111Binding0.3830.6961.000Uncertain 16-33451895-G-T-2.867Likely Benign0.078Likely BenignLikely Benign0.099Likely Benign0.80Neutral0.000Benign0.001Benign4.40Benign1.00Tolerated3.7750.27840.588411-2.616.00
c.1195G>T
A399S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A399S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly classify the variant as benign: REVEL, premPS, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect, while FoldX, Rosetta, and Foldetta are inconclusive. Grouping by agreement, all available predictors fall into the benign category; none predict pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also predicts benign, whereas Foldetta’s stability analysis remains uncertain. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.394753Structured0.407674Uncertain0.9390.4900.125-4.256Likely Benign0.100Likely BenignLikely Benign0.65Ambiguous0.11.13Ambiguous0.89Ambiguous-0.33Likely Benign0.161Likely Benign0.81Neutral0.001Benign0.001Benign5.65Benign0.86Tolerated0.24940.489711-2.616.00
c.3790G>A
G1264S
2D
AIThe SynGAP1 missense variant G1264S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: benign predictions are made by REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized classifies the variant as benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. Foldetta results are unavailable. Overall, the evidence strongly supports a benign classification, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.429200Structured0.762385Binding0.8970.5790.000-0.797Likely Benign0.096Likely BenignLikely Benign0.147Likely Benign0.82Neutral0.062Benign0.033Benign2.94Benign1.00Tolerated0.23760.425610-0.430.03
c.2765G>T
R922L
2D
AIThe SynGAP1 missense variant R922L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the substitution as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports it as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy methods that are available—AlphaMissense‑Optimized and the SGM‑Consensus—both support a benign interpretation. Therefore, the variant is most likely benign according to the consensus of predictive tools, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.549308Disordered0.955308Binding0.2770.8450.375-3.714Likely Benign0.546AmbiguousLikely Benign0.150Likely Benign0.84Neutral0.983Probably Damaging0.828Possibly Damaging3.04Benign1.00Tolerated0.20330.5022-3-28.3-43.03
c.1720C>A
L574M
2D
AIThe SynGAP1 missense variant L574M is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and FATHMM; ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta as benign. No predictions or stability results are missing or inconclusive. Based on the overall consensus, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.083462Structured0.026427Uncertain0.9270.2460.000-7.195In-Between0.098Likely BenignLikely Benign0.14Likely Benign0.20.34Likely Benign0.24Likely Benign-0.09Likely Benign0.113Likely Benign0.85Neutral0.691Possibly Damaging0.278Benign-1.29Pathogenic0.11Tolerated0.08940.308742-1.918.03
c.101A>G
Y34C
2D
AIThe SynGAP1 missense variant Y34C is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized reports Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability prediction is available. Overall, the majority of evidence points to a benign effect for Y34C, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.529623Disordered0.435847Uncertain0.3030.8550.375-3.730Likely Benign0.171Likely BenignLikely Benign0.196Likely Benign0.87Neutral0.943Possibly Damaging0.941Probably Damaging4.32Benign0.00Affected0.30100.27190-23.8-60.04
c.3727C>G
Q1243E
2D
AIThe SynGAP1 missense variant Q1243E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate a benign effect, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports “Likely Benign.” No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome; Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.545602Disordered0.433693Uncertain0.8870.5510.500-1.439Likely Benign0.090Likely BenignLikely Benign0.068Likely Benign0.88Neutral0.166Benign0.146Benign2.94Benign1.00Tolerated0.10670.0930220.00.98
c.458C>A
T153N
2D
AIThe SynGAP1 missense variant T153N is listed in ClinVar (ID 984906.0) with an “Uncertain” status and is not reported in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) predict pathogenic. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence supports a benign classification, and this is consistent with the ClinVar “Uncertain” designation rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.501700Disordered0.502105Binding0.2970.8180.625Conflicting 3-0.739Likely Benign0.226Likely BenignLikely Benign0.161Likely Benign0.88Neutral0.888Possibly Damaging0.537Possibly Damaging4.23Benign0.81Tolerated3.6150.13130.336300-2.813.00
c.302A>C
H101P
2D
AIThe SynGAP1 H101P missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.791621Disordered0.688356Binding0.3700.8840.625-2.042Likely Benign0.069Likely BenignLikely Benign0.170Likely Benign0.89Neutral0.943Possibly Damaging0.924Probably Damaging4.17Benign0.00Affected0.17770.35890-21.6-40.02
c.3629A>G
H1210R
2D
AIThe SynGAP1 missense variant H1210R is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity, so the pathogenic‑prediction group is empty. High‑accuracy assessments corroborate this benign consensus: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields “Likely Benign.” Foldetta results are not available, so they do not influence the interpretation. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.599170Disordered0.587579Binding0.9000.5670.3750.860Likely Benign0.173Likely BenignLikely Benign0.088Likely Benign0.89Neutral0.178Benign0.089Benign3.25Benign1.00Tolerated0.15350.238420-1.319.05
c.3832C>G
P1278A
2D
AIThe SynGAP1 missense variant P1278A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.806955Binding0.5320.7220.750-4.187Likely Benign0.067Likely BenignLikely Benign0.100Likely Benign0.89Neutral0.001Benign0.002Benign3.15Benign1.00Tolerated0.35970.33531-13.4-26.04
c.3850C>G
L1284V
2D
AIThe SynGAP1 missense variant L1284V is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.824557Binding0.4410.7480.875-4.329Likely Benign0.068Likely BenignLikely Benign0.064Likely Benign0.90Neutral0.008Benign0.006Benign2.92Benign1.00Tolerated0.14190.1883210.4-14.03
c.2027G>C
S676T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S676T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and Rosetta. No tool predicts a pathogenic outcome; the only inconclusive results are from FoldX (Uncertain) and Foldetta (Uncertain). High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign, and Foldetta remains Uncertain. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.209395Structured0.113632Uncertain0.5510.3380.125-5.621Likely Benign0.092Likely BenignLikely Benign0.79Ambiguous0.10.34Likely Benign0.57Ambiguous-0.36Likely Benign0.098Likely Benign0.91Neutral0.050Benign0.017Benign3.52Benign1.00Tolerated0.15750.6286110.114.03
c.1918A>T
T640S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T640S is listed in ClinVar as Benign (ClinVar ID 2980241.0) and is present in the gnomAD database (gnomAD ID 6‑33441177‑A‑T). Prediction tools that agree on a benign effect include REVEL, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the only inconclusive result is from FoldX, which is treated as unavailable. High‑accuracy assessments confirm benignity: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is benign; and Foldetta, which integrates FoldX‑MD and Rosetta outputs, is benign. Overall, the variant is most likely benign, and this conclusion is consistent with its ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.066181Structured0.137043Uncertain0.8930.2840.000Benign 16-33441177-A-T16.20e-7-2.371Likely Benign0.062Likely BenignLikely Benign-0.78Ambiguous0.10.43Likely Benign-0.18Likely Benign-0.30Likely Benign0.088Likely Benign0.92Neutral0.000Benign0.001Benign3.60Benign0.33Tolerated3.37300.34060.348411-0.1-14.03
c.1919C>G
T640S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T640S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: AlphaMissense‑Default, AlphaMissense‑Optimized, ESM1b, FATHMM, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, premPS, Foldetta, Rosetta, REVEL, and the SGM‑Consensus score (Likely Benign) all classify the change as tolerated. No tool predicts pathogenicity; the only inconclusive result is from FoldX, which is listed as Uncertain. High‑accuracy methods corroborate the benign assessment: AlphaMissense‑Optimized predicts Benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) reports Benign. Consequently, the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which has no entry for this change.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.066181Structured0.137043Uncertain0.8930.2840.000-2.371Likely Benign0.062Likely BenignLikely Benign-0.78Ambiguous0.10.43Likely Benign-0.18Likely Benign-0.30Likely Benign0.109Likely Benign0.92Neutral0.000Benign0.001Benign3.60Benign0.33Tolerated3.37300.34060.348411-0.1-14.03
c.2510T>G
V837G
2D
AIThe SynGAP1 missense variant V837G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic impact. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are not available, so they do not influence the overall assessment. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.525368Disordered0.626284Binding0.3180.8710.125-2.599Likely Benign0.315Likely BenignLikely Benign0.187Likely Benign0.93Neutral0.997Probably Damaging0.999Probably Damaging3.18Benign1.00Tolerated0.22600.2422-1-3-4.6-42.08
c.3191A>C
Q1064P
2D
AIThe SynGAP1 missense variant Q1064P is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875-2.032Likely Benign0.058Likely BenignLikely Benign0.270Likely Benign0.93Neutral0.001Benign0.001Benign4.23Benign0.20Tolerated0.28190.47660-11.9-31.01
c.526A>C
S176R
2D
AIThe SynGAP1 missense variant S176R is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM, whereas polyPhen‑2 HumDiv, AlphaMissense‑Default, and AlphaMissense‑Optimized predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic, while the SGM‑Consensus remains likely benign; Foldetta results are unavailable. Overall, the balance of evidence favors a benign interpretation, and this assessment does not conflict with the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.562014Disordered0.466016Uncertain0.3800.5970.375Uncertain 1-6.492Likely Benign0.987Likely PathogenicLikely Pathogenic0.247Likely Benign0.94Neutral0.718Possibly Damaging0.168Benign4.16Benign0.87Tolerated0.06970.31600-1-3.769.11
c.528C>A
S176R
2D
AIThe SynGAP1 missense variant S176R has no ClinVar record and is not present in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and the SGM‑Consensus (majority vote) all classify the change as benign or likely benign. In contrast, polyPhen‑2 HumDiv, AlphaMissense‑Default, and AlphaMissense‑Optimized predict a pathogenic impact. High‑accuracy assessments are mixed: AlphaMissense‑Optimized reports a pathogenic outcome, whereas the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect; Foldetta data are unavailable. Overall, the majority of predictions support a benign interpretation, and there is no ClinVar entry to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.562014Disordered0.466016Uncertain0.3800.5970.375-6.492Likely Benign0.987Likely PathogenicLikely Pathogenic0.230Likely Benign0.94Neutral0.718Possibly Damaging0.168Benign4.16Benign0.87Tolerated0.06970.31600-1-3.769.11
c.528C>G
S176R
2D
AIThe SynGAP1 missense variant S176R has no ClinVar record and is not present in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and the SGM‑Consensus (majority vote) all classify the change as benign or likely benign. In contrast, polyPhen‑2 HumDiv, AlphaMissense‑Default, and AlphaMissense‑Optimized predict a pathogenic impact. High‑accuracy assessments are mixed: AlphaMissense‑Optimized reports a pathogenic outcome, whereas the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect; Foldetta data are unavailable. Overall, the majority of predictions support a benign interpretation, and there is no ClinVar entry to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.562014Disordered0.466016Uncertain0.3800.5970.375-6.492Likely Benign0.987Likely PathogenicLikely Pathogenic0.230Likely Benign0.94Neutral0.718Possibly Damaging0.168Benign4.16Benign0.87Tolerated0.06970.31600-1-3.769.11
c.361G>C
A121P
2D
AIThe SynGAP1 missense variant A121P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that A121P is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.779859Disordered0.661304Binding0.3620.8880.750-3.210Likely Benign0.077Likely BenignLikely Benign0.062Likely Benign0.95Neutral0.000Benign0.001Benign4.18Benign0.03Affected0.21970.61961-1-3.426.04
c.3970C>A
P1324T
2D
AIThe SynGAP1 missense variant P1324T is listed in gnomAD (ID 6‑33451844‑C‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; pathogenic predictions come from polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the available predictions points to a benign effect, and this conclusion does not contradict any ClinVar status, as no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.891961Disordered0.899181Binding0.4320.7930.8756-33451844-C-A-5.289Likely Benign0.077Likely BenignLikely Benign0.072Likely Benign0.95Neutral0.588Possibly Damaging0.175Benign4.43Benign0.00Affected4.3210.18630.4761-100.93.99
c.3938C>A
P1313Q
2D
AIThe SynGAP1 missense variant P1313Q is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, is not available for this variant. Overall, the consensus of all available predictions strongly supports a benign classification, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.970301Binding0.4520.9020.750-4.533Likely Benign0.077Likely BenignLikely Benign0.063Likely Benign0.99Neutral0.324Benign0.287Benign4.31Benign0.15Tolerated0.17480.56510-1-1.931.01
c.2827G>C
G943R
2D
AIThe SynGAP1 missense variant G943R is reported in gnomAD (variant ID 6-33443379‑G‑C) but has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity; only ESM1b is uncertain. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions strongly supports a benign classification, and this is consistent with the absence of a ClinVar pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.973328Disordered0.860437Binding0.3720.9100.7506-33443379-G-C16.20e-7-7.159In-Between0.335Likely BenignLikely Benign0.308Likely Benign1.00Neutral0.411Benign0.062Benign2.86Benign0.94Tolerated4.3240.09760.4933-2-3-4.199.14
c.3858A>C
E1286D
2D
AIThe SynGAP1 missense variant E1286D is not reported in ClinVar and is absent from gnomAD. All available in silico predictors classify it as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta results are not available. Based on the unanimous benign predictions and lack of ClinVar evidence, the variant is most likely benign and does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.817022Binding0.5440.7650.750-4.010Likely Benign0.081Likely BenignLikely Benign0.036Likely Benign1.02Neutral0.001Benign0.004Benign2.96Benign1.00Tolerated3.7750.21140.3141320.0-14.0310.1016/j.ajhg.2020.11.011
c.3858A>T
E1286D
2D
AIThe SynGAP1 missense variant E1286D is listed in ClinVar (ID 469159.0) with an “Uncertain” clinical significance and is present in gnomAD (variant ID 6‑33447906‑A‑T). All evaluated in‑silico predictors classify the substitution as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. No tool in the set predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status is unavailable. Overall, the computational evidence strongly supports a benign effect, and this conclusion does not contradict the current ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.817022Binding0.5440.7650.750Conflicting 46-33447906-A-T1439.22e-5-4.010Likely Benign0.081Likely BenignLikely Benign0.036Likely Benign1.02Neutral0.001Benign0.004Benign2.96Benign1.00Tolerated3.7750.21140.3141320.0-14.0310.1016/j.ajhg.2020.11.011
c.1313C>T
A438V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A438V is not reported in ClinVar (ClinVar ID None) but is present in gnomAD (gnomAD ID 6‑33438218‑C‑T). Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates “Likely Benign”; Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, is inconclusive (Uncertain). Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.147574Structured0.290154Uncertain0.9290.2930.0006-33438218-C-T31.86e-61.405Likely Benign0.073Likely BenignLikely Benign-0.36Likely Benign0.0-0.70Ambiguous-0.53Ambiguous-1.21Stabilizing0.046Likely Benign1.03Neutral0.000Benign0.000Benign4.45Benign0.97Tolerated3.38260.09040.5292002.428.0510.1016/j.ajhg.2020.11.011
c.1396T>A
S466T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S466T is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Foldetta, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. Uncertain results come from Rosetta and premPS. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, the SGM‑Consensus as Likely Benign, and Foldetta as Benign. Taken together, the majority of evidence points to a benign impact. Therefore, the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.311707Structured0.322353Uncertain0.9330.2270.000-5.488Likely Benign0.314Likely BenignLikely Benign0.30Likely Benign0.2-1.02Ambiguous-0.36Likely Benign-0.65Ambiguous0.414Likely Benign1.05Neutral0.740Possibly Damaging0.872Possibly Damaging-1.51Pathogenic1.00Tolerated0.09280.5152110.114.03
c.3844G>C
E1282Q
2D
AIThe SynGAP1 missense variant E1282Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.817364Binding0.4650.7250.875-2.785Likely Benign0.106Likely BenignLikely Benign0.079Likely Benign1.05Neutral0.004Benign0.003Benign2.70Benign0.31Tolerated0.09650.5651220.0-0.98
c.1563G>C
E521D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense change E521D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Only two tools, polyPhen‑2 HumDiv and HumVar, predict a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as Benign; the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields Likely Benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, reports a Benign effect. No prediction or stability result is missing or inconclusive. Based on the collective evidence, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.086953Structured0.062387Uncertain0.8650.3490.000-4.963Likely Benign0.372AmbiguousLikely Benign0.13Likely Benign0.00.17Likely Benign0.15Likely Benign-0.29Likely Benign0.227Likely Benign1.07Neutral0.986Probably Damaging0.989Probably Damaging3.40Benign0.92Tolerated0.20260.3721320.0-14.03
c.1563G>T
E521D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 E521D missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) all indicate benign or likely benign. Only two tools—polyPhen‑2 HumDiv and HumVar—predict a pathogenic outcome. The high‑accuracy methods give a consistent benign signal: AlphaMissense‑Optimized is benign, the SGM‑Consensus is likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) is benign. No prediction or folding stability result is missing or inconclusive. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.086953Structured0.062387Uncertain0.8650.3490.000-4.963Likely Benign0.372AmbiguousLikely Benign0.13Likely Benign0.00.17Likely Benign0.15Likely Benign-0.29Likely Benign0.227Likely Benign1.07Neutral0.986Probably Damaging0.989Probably Damaging3.40Benign0.92Tolerated0.20260.3721320.0-14.03
c.3104C>G
P1035R
2D
AIThe SynGAP1 missense variant P1035R is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and there is no ClinVar entry to contradict this assessment. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.945666Disordered0.989572Binding0.3000.7560.625-4.534Likely Benign0.604Likely PathogenicLikely Benign0.119Likely Benign1.07Neutral0.970Probably Damaging0.728Possibly Damaging2.89Benign0.93Tolerated0.14240.42010-2-2.959.07
c.3961C>A
P1321T
2D
AIThe SynGAP1 missense variant P1321T is catalogued in gnomAD (ID 6‑33451835‑C‑A) but has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the variant as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the evidence strongly supports a benign classification, and this conclusion is consistent with the absence of a ClinVar pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.827927Disordered0.933505Binding0.4630.8280.8756-33451835-C-A-4.946Likely Benign0.074Likely BenignLikely Benign0.058Likely Benign1.07Neutral0.115Benign0.012Benign4.25Benign1.00Tolerated3.7750.20160.5901-100.93.99
c.2842G>A
G948S
2D
AIThe SynGAP1 missense variant G948S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools that assess sequence conservation and structural impact uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this benign assessment: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the collective evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.862121Binding0.3650.9190.750-4.760Likely Benign0.080Likely BenignLikely Benign0.177Likely Benign1.09Neutral0.068Benign0.026Benign4.57Benign1.00Tolerated0.24660.550210-0.430.03
c.3133G>C
A1045P
2D
AIThe SynGAP1 missense variant A1045P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also predicts Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975609Disordered0.948874Binding0.3520.8820.750-2.260Likely Benign0.078Likely BenignLikely Benign0.099Likely Benign1.09Neutral0.586Possibly Damaging0.223Benign2.64Benign0.24Tolerated0.21300.53321-1-3.426.04
c.964G>T
A322S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A322S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only FATHMM predicts a pathogenic outcome. Grouping by consensus, the benign‑predicting tools outnumber the single pathogenic prediction. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also indicates a benign effect. No prediction or stability result is missing or inconclusive. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.175930Structured0.425745Uncertain0.9380.3340.000-1.424Likely Benign0.058Likely BenignLikely Benign0.41Likely Benign0.20.38Likely Benign0.40Likely Benign-0.44Likely Benign0.127Likely Benign1.09Neutral0.010Benign0.010Benign2.00Pathogenic0.67Tolerated0.26960.525311-2.616.00
c.991T>A
S331T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S331T is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, Rosetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while FoldX and premPS are inconclusive (Uncertain). High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign; and Foldetta (combining FoldX‑MD and Rosetta outputs) is benign. Taken together, the majority of evidence indicates that S331T is most likely benign, and this conclusion does not contradict the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.433034Structured0.346458Uncertain0.6580.4750.250-2.474Likely Benign0.071Likely BenignLikely Benign0.60Ambiguous0.2-0.10Likely Benign0.25Likely Benign-0.72Ambiguous0.095Likely Benign1.13Neutral0.003Benign0.002Benign1.86Pathogenic0.98Tolerated0.15050.4552110.114.03
c.1319A>G
N440S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant N440S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: SGM‑Consensus, REVEL, Rosetta, Foldetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign or likely benign. Only FoldX and premPS returned uncertain results, which are treated as unavailable. High‑accuracy methods corroborate this: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is likely benign; and Foldetta, which integrates FoldX‑MD and Rosetta outputs, is benign. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.191378Structured0.267204Uncertain0.9290.2450.000-1.753Likely Benign0.058Likely BenignLikely Benign0.52Ambiguous0.10.08Likely Benign0.30Likely Benign-0.50Ambiguous0.104Likely Benign1.15Neutral0.001Benign0.000Benign3.53Benign0.92Tolerated0.20240.3556112.7-27.03
c.2379G>C
K793N
2D
AIThe SynGAP1 missense variant K793N is catalogued in gnomAD (6‑33442931‑G‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all classify it as benign, and the SGM‑Consensus score (Likely Benign) supports this view. Only AlphaMissense‑Default predicts pathogenicity. High‑accuracy assessments further reinforce the benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields a benign classification. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that K793N is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.971072Disordered0.426071Uncertain0.3440.9010.8756-33442931-G-C42.48e-6-5.162Likely Benign0.632Likely PathogenicLikely Benign0.040Likely Benign1.18Neutral0.174Benign0.135Benign4.13Benign0.47Tolerated4.0730.44290.1976010.4-14.07
c.2379G>T
K793N
2D
AIThe SynGAP1 missense variant K793N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. Only AlphaMissense‑Default predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is also benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.971072Disordered0.426071Uncertain0.3440.9010.875-5.162Likely Benign0.632Likely PathogenicLikely Benign0.040Likely Benign1.18Neutral0.174Benign0.135Benign4.13Benign0.47Tolerated4.0730.44290.1976010.4-14.07
c.3979C>A
P1327T
2D
AIThe SynGAP1 missense variant P1327T is reported in gnomAD (ID 6‑33451853‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign; Foldetta results are not available. Taken together, the majority of evidence points to a benign impact. There is no ClinVar classification to contradict this conclusion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.896620Disordered0.900145Binding0.3690.7770.8756-33451853-C-A-5.263Likely Benign0.150Likely BenignLikely Benign0.144Likely Benign1.20Neutral0.994Probably Damaging0.908Possibly Damaging4.51Benign1.00Tolerated3.7750.13860.4779-100.93.99
c.1853A>G
Q618R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q618R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus, REVEL, FoldX, Foldetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while Rosetta and premPS are inconclusive. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is likely benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also predicts benign. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.175930Structured0.138725Uncertain0.9040.2400.000-2.513Likely Benign0.207Likely BenignLikely Benign-0.43Likely Benign0.10.60Ambiguous0.09Likely Benign-0.66Ambiguous0.285Likely Benign1.22Neutral0.005Benign0.009Benign-1.24Pathogenic1.00Tolerated0.12180.116311-1.028.06
c.740A>G
Q247R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q247R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Uncertain predictions come from premPS and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as benign. No prediction or folding stability result is missing or inconclusive. Based on the overall consensus of the majority of tools and the high‑accuracy methods, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.490133Structured0.283012Uncertain0.8220.3390.250-4.022Likely Benign0.442AmbiguousLikely Benign-0.38Likely Benign0.00.21Likely Benign-0.09Likely Benign-0.91Ambiguous0.471Likely Benign1.22Neutral0.948Possibly Damaging0.533Possibly Damaging5.91Benign1.00Tolerated0.11960.132411-1.028.06
c.2350G>A
A784T
2D
AIThe SynGAP1 missense variant A784T is listed in ClinVar (ID 962668.0) as Benign and is not reported in gnomAD. Across the available in‑silico predictors, every tool examined—REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—consistently classifies the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized reports a benign effect, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. A Foldetta stability analysis is unavailable, so it does not influence the overall interpretation. Based on the unanimous benign predictions and the ClinVar designation, the variant is most likely benign, with no contradiction to the ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.801317Disordered0.708872Binding0.3140.8960.625Benign 1-3.579Likely Benign0.089Likely BenignLikely Benign0.046Likely Benign1.23Neutral0.001Benign0.006Benign2.92Benign1.00Tolerated3.6460.14930.665910-2.530.03
c.2493G>C
E831D
2D
AIThe SynGAP1 missense variant E831D is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443045‑G‑C). All available in‑silico predictors classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool reports a pathogenic or likely‑pathogenic outcome. Grouping by agreement, the benign‑predicting tools comprise the entire set, while no pathogenic predictions are present. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields a benign classification. Foldetta results are unavailable. Overall, the computational evidence strongly supports a benign effect, and this conclusion does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.626927Disordered0.617732Binding0.3190.8740.375Uncertain 16-33443045-G-C16.19e-7-3.055Likely Benign0.063Likely BenignLikely Benign0.073Likely Benign1.23Neutral0.002Benign0.002Benign2.64Benign0.77Tolerated3.7750.15370.4530320.0-14.03
c.2493G>T
E831D
2D
AIThe SynGAP1 missense variant E831D is not reported in ClinVar and is absent from gnomAD. All available in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are not available. Based on the consensus of all predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.626927Disordered0.617732Binding0.3190.8740.375-3.055Likely Benign0.063Likely BenignLikely Benign0.073Likely Benign1.23Neutral0.002Benign0.002Benign2.64Benign0.77Tolerated3.7750.15370.4530320.0-14.03
c.3035C>G
P1012R
2D
AIThe SynGAP1 missense variant P1012R is not reported in ClinVar and is absent from gnomAD, indicating no documented population frequency. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, is not available for this variant. Overall, the consensus of all available predictions strongly supports a benign classification, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.894674Binding0.3190.8660.625-4.413Likely Benign0.104Likely BenignLikely Benign0.034Likely Benign1.24Neutral0.000Benign0.002Benign2.89Benign0.88Tolerated0.13390.30830-2-2.959.07
c.3940C>A
P1314T
2D
AIThe SynGAP1 missense variant P1314T is present in gnomAD (ID 6‑33451814‑C‑A) but has no ClinVar entry. Across a broad panel of in silico predictors, every tool reports a benign effect. Benign predictions come from REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; no tool in the set predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized returns a benign prediction, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—labels the variant as Likely Benign. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status remains unavailable. Overall, the computational evidence overwhelmingly supports a benign impact, and this is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign, and this is consistent with the lack of a ClinVar pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.971592Binding0.4670.9030.7506-33451814-C-A-4.083Likely Benign0.096Likely BenignLikely Benign0.066Likely Benign1.26Neutral0.061Benign0.045Benign4.32Benign0.97Tolerated3.7750.17910.5626-100.93.99
c.1081C>A
Q361K
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q361K is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in‑silico predictors indicates a benign effect: REVEL, FoldX, Rosetta, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the substitution as tolerated, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also classifies it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and FATHMM predict a pathogenic outcome. High‑accuracy tools that integrate structural and evolutionary information—AlphaMissense‑Optimized, the SGM‑Consensus, and Foldetta (combining FoldX‑MD and Rosetta outputs)—all return benign predictions. No prediction or folding‑stability result is missing or inconclusive. Based on the aggregate evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.305330Structured0.427593Uncertain0.9450.5340.250-5.147Likely Benign0.286Likely BenignLikely Benign0.17Likely Benign0.00.36Likely Benign0.27Likely Benign-0.44Likely Benign0.217Likely Benign1.29Neutral0.969Probably Damaging0.930Probably Damaging1.73Pathogenic1.00Tolerated0.17390.470111-0.40.04
c.415A>G
S139G
2D
AIThe SynGAP1 missense variant S139G is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool predicts pathogenicity. The high‑accuracy consensus, SGM‑Consensus, also reports the variant as Likely Benign, and AlphaMissense‑Optimized confirms a benign prediction. Foldetta, a protein‑folding stability method, has no available result for this variant. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.553315Disordered0.600637Binding0.3530.9000.2501.647Likely Benign0.159Likely BenignLikely Benign0.116Likely Benign1.29Neutral0.000Benign0.000Benign4.29Benign1.00Tolerated0.27120.3414100.4-30.03
c.1932C>A
D644E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant D644E is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). No tool predicts a pathogenic outcome; the only inconclusive result is from Rosetta, which is treated as unavailable. High‑accuracy assessments confirm a benign impact: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) is benign. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.066181Structured0.248888Uncertain0.8830.3200.000-1.778Likely Benign0.178Likely BenignLikely Benign-0.17Likely Benign0.1-0.51Ambiguous-0.34Likely Benign-0.47Likely Benign0.132Likely Benign1.31Neutral0.000Benign0.000Benign3.55Benign1.00Tolerated0.15280.6186320.014.03
c.1932C>G
D644E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant D644E is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). No tool predicts a pathogenic outcome; the only inconclusive result is from Rosetta, which is treated as unavailable. High‑accuracy assessments confirm a benign impact: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) is benign. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.066181Structured0.248888Uncertain0.8830.3200.000-1.778Likely Benign0.178Likely BenignLikely Benign-0.17Likely Benign0.1-0.51Ambiguous-0.34Likely Benign-0.47Likely Benign0.132Likely Benign1.31Neutral0.000Benign0.000Benign3.55Benign1.00Tolerated0.15280.6186320.014.03
c.3943T>A
W1315R
2D
AIThe SynGAP1 missense variant W1315R is not reported in ClinVar and has no entry in gnomAD, indicating it is not catalogued in these databases. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all classify the change as benign or likely benign. Only AlphaMissense‑Default predicts a pathogenic outcome, representing the sole discordant signal. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign. The Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the preponderance of evidence from multiple prediction algorithms and high‑accuracy tools points to a benign effect, and this conclusion does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.885302Disordered0.973142Binding0.4030.8890.7500.205Likely Benign0.660Likely PathogenicLikely Benign0.114Likely Benign1.31Neutral0.000Benign0.001Benign4.37Benign0.91Tolerated3.7750.43170.03842-3-3.6-30.03
c.3943T>C
W1315R
2D
AIThe SynGAP1 missense variant W1315R is listed in ClinVar (ID 1029092.0) with an “Uncertain” clinical significance and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score (which is a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only AlphaMissense‑Default predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as benign; Foldetta results are not available for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.885302Disordered0.973142Binding0.4030.8890.750Uncertain 10.205Likely Benign0.660Likely PathogenicLikely Benign0.114Likely Benign1.31Neutral0.000Benign0.001Benign4.37Benign0.91Tolerated3.7750.43170.03842-3-3.6-30.03
c.3777C>G
I1259M
2D
AIThe SynGAP1 missense variant I1259M is catalogued in gnomAD (ID 6‑33446769‑C‑G) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score, whereas PolyPhen‑2 (HumDiv and HumVar) classify the change as pathogenic. The high‑accuracy AlphaMissense‑Optimized tool reports a benign effect, and the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates benign. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.494003Structured0.576405Binding0.8850.5740.2506-33446769-C-G21.24e-6-5.177Likely Benign0.447AmbiguousLikely Benign0.227Likely Benign1.35Neutral0.999Probably Damaging0.998Probably Damaging2.87Benign1.00Tolerated3.7750.05760.235812-2.618.03
c.3910C>G
P1304A
2D
AIThe SynGAP1 missense variant P1304A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on current predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.885302Disordered0.886417Binding0.4750.8660.875-4.072Likely Benign0.058Likely BenignLikely Benign0.069Likely Benign1.35Neutral0.001Benign0.002Benign3.09Benign1.00Tolerated0.29230.41171-13.4-26.04
c.82T>C
S28P
2D
AIThe SynGAP1 missense variant S28P is listed in ClinVar (ID 1500161.0) with an uncertain significance designation and is not reported in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only SIFT indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta stability analysis is unavailable. Overall, the collective evidence points to a benign classification for S28P, which is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.545602Disordered0.438157Uncertain0.3540.8840.125Uncertain 1-3.309Likely Benign0.051Likely BenignLikely Benign0.047Likely Benign1.37Neutral0.000Benign0.000Benign4.53Benign0.00Affected4.3210.24320.54991-1-0.810.04
c.3836C>A
A1279D
2D
AIThe SynGAP1 missense variant A1279D is catalogued in gnomAD (ID 6‑33447884‑C‑A) but has no ClinVar entry. Across the spectrum of in‑silico predictors, every tool listed—REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—consistently classifies the substitution as benign. No pathogenic predictions are reported. Grouping by agreement, all available tools fall into the benign category, with no tools indicating pathogenicity. High‑accuracy assessments further support this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no result for this variant and is therefore considered unavailable. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.842060Disordered0.814139Binding0.4850.7240.7506-33447884-C-A-3.914Likely Benign0.172Likely BenignLikely Benign0.087Likely Benign1.38Neutral0.000Benign0.000Benign2.89Benign0.35Tolerated3.7750.15050.2062-20-5.344.01
c.3893A>G
Q1298R
2D
AIThe SynGAP1 missense variant Q1298R is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are unavailable. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.823549Disordered0.895297Binding0.4100.8210.750-2.643Likely Benign0.174Likely BenignLikely Benign0.112Likely Benign1.38Neutral0.000Benign0.001Benign3.15Benign1.00Tolerated0.11420.162811-1.028.06
c.3964G>T
A1322S
2D
AIThe SynGAP1 missense variant A1322S is catalogued in gnomAD (ID 6‑33451838‑G‑T) but has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the variant as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Overall, the evidence strongly supports a benign classification, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.921040Binding0.4660.8250.8756-33451838-G-T-4.570Likely Benign0.073Likely BenignLikely Benign0.086Likely Benign1.38Neutral0.003Benign0.001Benign4.48Benign0.57Tolerated3.7750.29540.608411-2.616.00
c.3925G>C
V1309L
2D
AIThe SynGAP1 missense variant V1309L is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this trend: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on current predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.712013Disordered0.948596Binding0.4020.9070.750-2.543Likely Benign0.102Likely BenignLikely Benign0.108Likely Benign1.41Neutral0.000Benign0.002Benign2.99Benign1.00Tolerated0.09440.421221-0.414.03
c.3925G>T
V1309L
2D
AIThe SynGAP1 missense variant V1309L is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, is not available for this variant. Overall, the computational evidence strongly supports a benign impact, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.712013Disordered0.948596Binding0.4020.9070.750-2.543Likely Benign0.102Likely BenignLikely Benign0.108Likely Benign1.41Neutral0.000Benign0.002Benign2.99Benign1.00Tolerated0.09440.421221-0.414.03
c.1071C>A
H357Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant H357Q is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that assess sequence conservation, structural impact, or functional effect all converge on a benign outcome: REVEL, FoldX, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate benign. No tool predicts pathogenicity. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also reports a benign effect. Based on the uniform predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.203355Structured0.399052Uncertain0.8610.4130.250-4.370Likely Benign0.163Likely BenignLikely Benign0.06Likely Benign0.2-0.03Likely Benign0.02Likely Benign-0.35Likely Benign0.025Likely Benign1.42Neutral0.013Benign0.007Benign4.49Benign1.00Tolerated0.17160.385030-0.3-9.01
c.1071C>G
H357Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant H357Q is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that assess sequence conservation, structural impact, or functional effect all converge on a benign outcome: REVEL, FoldX, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate benign. No tool predicts pathogenicity. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also reports a benign effect. Based on the uniform predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.203355Structured0.399052Uncertain0.8610.4130.250-4.370Likely Benign0.163Likely BenignLikely Benign0.06Likely Benign0.2-0.03Likely Benign0.02Likely Benign-0.35Likely Benign0.025Likely Benign1.42Neutral0.013Benign0.007Benign4.49Benign1.00Tolerated0.17160.385030-0.3-9.01
c.3847C>G
P1283A
2D
AIThe SynGAP1 missense variant P1283A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign. Foldetta results are unavailable, so they do not influence the overall assessment. Consequently, the variant is most likely benign based on the collective predictions, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.762850Disordered0.819686Binding0.4840.7320.875-3.656Likely Benign0.055Likely BenignLikely Benign0.070Likely Benign1.42Neutral0.004Benign0.004Benign2.79Benign1.00Tolerated0.28740.33701-13.4-26.04
c.1189T>G
C397G
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant C397G is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that reach consensus all indicate a benign effect: REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the variant as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also classifies it as “Likely Benign.” No tool predicts pathogenicity. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, while Foldetta (combining FoldX‑MD and Rosetta outputs) is inconclusive. No pathogenic predictions are present. Therefore, based on the available computational evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.429200Structured0.395774Uncertain0.7780.5510.2501.244Likely Benign0.096Likely BenignLikely Benign0.68Ambiguous0.21.42Ambiguous1.05Ambiguous0.04Likely Benign0.272Likely Benign1.51Neutral0.276Benign0.066Benign5.93Benign0.60Tolerated0.36780.3729-3-3-2.9-46.09
c.1057C>G
L353V
2D
AISynGAP1 missense variant L353V is not reported in ClinVar and is absent from gnomAD. Prediction tools that classify the variant as benign include REVEL, premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools predicting pathogenicity are FoldX and FATHMM, while Rosetta gives an uncertain result. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as likely benign. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as pathogenic. Overall, the balance of evidence favors a benign effect; this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.137348Structured0.373584Uncertain0.9260.3150.000-2.100Likely Benign0.078Likely BenignLikely Benign3.08Destabilizing0.91.48Ambiguous2.28Destabilizing-0.45Likely Benign0.074Likely Benign1.54Neutral0.002Benign0.002Benign1.46Pathogenic0.89Tolerated0.15670.3829210.4-14.03
c.3865A>C
K1289Q
2D
AIThe SynGAP1 missense variant K1289Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the evidence strongly supports a benign classification, and this conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.828700Binding0.5480.7870.625-2.940Likely Benign0.096Likely BenignLikely Benign0.066Likely Benign1.55Neutral0.004Benign0.004Benign3.09Benign1.00Tolerated0.40020.0590110.4-0.04
c.524A>C
Q175P
2D
AIThe SynGAP1 missense variant Q175P is reported in gnomAD (ID 6‑33435166‑A‑C) but has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all score the substitution as benign. The consensus from the SGM framework, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also classifies the variant as likely benign. High‑accuracy predictors corroborate this assessment: AlphaMissense‑Optimized predicts a benign outcome, and the SGM‑Consensus (majority vote) confirms a likely benign status. No high‑accuracy folding‑stability analysis (Foldetta) is available for this residue, so stability effects remain unassessed. Overall, the collective evidence points to a benign impact for Q175P, and this conclusion is consistent with the absence of a pathogenic ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.653063Disordered0.474689Uncertain0.3670.6180.3756-33435166-A-C16.20e-7-6.995Likely Benign0.432AmbiguousLikely Benign0.211Likely Benign1.55Neutral0.396Benign0.188Benign4.20Benign1.00Tolerated3.6150.20750.4584-101.9-31.01
c.3110T>A
I1037N
2D
AIThe SynGAP1 missense variant I1037N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a Likely Benign classification, while AlphaMissense‑Optimized remains uncertain. Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-3.955Likely Benign0.832Likely PathogenicAmbiguous0.131Likely Benign1.56Neutral0.666Possibly Damaging0.211Benign2.81Benign0.34Tolerated0.10220.1140-2-3-8.00.94
c.2795T>A
F932Y
2D
AIThe SynGAP1 missense variant F932Y is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority of other predictors (polyPhen‑2 HumDiv and HumVar) suggest pathogenic. When predictions are grouped by agreement, the benign‑predicating tools outnumber the pathogenic ones, and the single uncertain call from AlphaMissense‑Default does not alter this balance. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized classifies the variant as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports it as Likely Benign. Foldetta data are unavailable. Overall, the computational evidence overwhelmingly supports a benign classification, and this is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.989197Binding0.2930.8580.500-5.248Likely Benign0.540AmbiguousLikely Benign0.180Likely Benign1.58Neutral0.997Probably Damaging0.987Probably Damaging3.13Benign0.74Tolerated0.14730.200373-4.116.00
c.1018G>T
A340S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A340S is reported in gnomAD (variant ID 6‑33437923‑G‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only FATHMM predicts pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a benign majority (3 benign vs. 1 pathogenic). High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign; the SGM‑Consensus is benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also predicts benign. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.390993Structured0.410781Uncertain0.5580.4850.2506-33437923-G-T16.20e-7-0.705Likely Benign0.083Likely BenignLikely Benign0.15Likely Benign0.00.27Likely Benign0.21Likely Benign-0.46Likely Benign0.083Likely Benign1.62Neutral0.007Benign0.008Benign1.93Pathogenic0.51Tolerated3.42130.28520.630911-2.616.00
c.1586T>G
I529S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I529S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, FoldX, Foldetta, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) all indicate benign or likely benign. In contrast, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM predict pathogenicity, while Rosetta remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign, the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts benign stability. Overall, the majority of evidence supports a benign classification and is consistent with the absence of a ClinVar assertion. Therefore, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.318242Structured0.019545Uncertain0.9010.4030.000-0.171Likely Benign0.197Likely BenignLikely Benign0.13Likely Benign0.3-0.53Ambiguous-0.20Likely Benign0.00Likely Benign0.383Likely Benign1.62Neutral0.979Probably Damaging0.820Possibly Damaging-1.14Pathogenic0.40Tolerated0.24020.0887-1-2-5.3-26.08
c.1279C>A
H427N
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant H427N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: SIFT, PolyPhen‑2 (HumDiv and HumVar), REVEL, PROVEAN, premPS, FoldX, Rosetta, and AlphaMissense‑Default all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields “Likely Benign,” and Foldetta (combining FoldX‑MD and Rosetta outputs) also reports a benign outcome. With all available evidence pointing to a neutral effect and no conflicting ClinVar annotation, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.081712Structured0.394261Uncertain0.9620.2870.0001.162Likely Benign0.045Likely BenignLikely Benign-0.11Likely Benign0.10.39Likely Benign0.14Likely Benign-0.48Likely Benign0.100Likely Benign1.63Neutral0.010Benign0.006Benign3.62Benign0.46Tolerated0.15070.241821-0.3-23.04
c.1060G>A
A354T
2D
AIThe SynGAP1 missense variant A354T is not reported in ClinVar and is absent from gnomAD. Prediction tools that classify the variant as benign include REVEL, FoldX, Rosetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Only FATHMM predicts a pathogenic effect. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is Likely Benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also reports a benign result. No predictions or folding‑stability analyses are missing or inconclusive. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.203355Structured0.381329Uncertain0.8820.3350.125-2.812Likely Benign0.070Likely BenignLikely Benign0.37Likely Benign0.70.11Likely Benign0.24Likely Benign-0.52Ambiguous0.097Likely Benign1.72Neutral0.002Benign0.001Benign1.75Pathogenic0.45Tolerated0.17310.649610-2.530.03
c.3913A>G
T1305A
2D
AIThe SynGAP1 missense variant T1305A is listed in ClinVar (ID 411587.0) with an “Uncertain” clinical significance and is present in the gnomAD database (variant ID 6‑33451787‑A‑G). All evaluated in‑silico predictors classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool reports a pathogenic or likely pathogenic outcome. High‑accuracy assessments reinforce this benign prediction: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are unavailable. Overall, the computational evidence overwhelmingly supports a benign effect, and this conclusion does not contradict the ClinVar “Uncertain” status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.791621Disordered0.894658Binding0.3900.8730.875Conflicting 46-33451787-A-G301.86e-5-2.692Likely Benign0.055Likely BenignLikely Benign0.069Likely Benign1.74Neutral0.000Benign0.001Benign3.24Benign1.00Tolerated3.7750.45330.4746102.5-30.03
c.591G>C
E197D
2D
AIThe SynGAP1 missense variant E197D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable. Overall, the consensus of all available predictions strongly supports a benign classification, and this is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.349426Structured0.431896Uncertain0.4520.4920.1250.784Likely Benign0.130Likely BenignLikely Benign0.066Likely Benign1.81Neutral0.000Benign0.000Benign4.66Benign1.00Tolerated0.15790.3345320.0-14.03
c.591G>T
E197D
2D
AIThe SynGAP1 missense variant E197D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions strongly supports a benign classification, and this is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.349426Structured0.431896Uncertain0.4520.4920.1250.784Likely Benign0.130Likely BenignLikely Benign0.066Likely Benign1.81Neutral0.000Benign0.000Benign4.66Benign1.00Tolerated0.15790.3345320.0-14.03
c.3901C>T
P1301S
2D
AIThe SynGAP1 missense variant P1301S is not reported in ClinVar and is absent from gnomAD. All available in‑silico predictors classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence strongly supports a benign effect, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.728858Disordered0.885064Binding0.4470.8410.875-4.537Likely Benign0.071Likely BenignLikely Benign0.087Likely Benign1.84Neutral0.000Benign0.001Benign3.29Benign0.95Tolerated0.27990.34361-10.8-10.04
c.1936C>A
L646M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L646M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome. Predictions that are inconclusive are FoldX, Rosetta, and Foldetta. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as likely benign, while Foldetta’s stability analysis remains uncertain. Overall, the evidence overwhelmingly supports a benign classification for this variant, and this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.048328Structured0.303751Uncertain0.9410.3440.000-1.911Likely Benign0.152Likely BenignLikely Benign0.70Ambiguous0.11.66Ambiguous1.18Ambiguous-1.10Stabilizing0.106Likely Benign1.86Neutral0.211Benign0.055Benign3.57Benign1.00Tolerated0.20410.342742-1.918.03
c.2032A>G
S678G
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S678G is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include AlphaMissense‑Default, AlphaMissense‑Optimized, ESM1b, FATHMM, PROVEAN, PolyPhen‑2 HumDiv, PolyPhen‑2 HumVar, SIFT, REVEL, FoldX, premPS, and Foldetta. No tool predicts a pathogenic outcome; the only inconclusive result is from Rosetta, which is listed as “Uncertain.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is “Likely Benign,” and Foldetta (combining FoldX‑MD and Rosetta outputs) is benign. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.301917Structured0.123585Uncertain0.6600.3210.000-4.379Likely Benign0.069Likely BenignLikely Benign0.24Likely Benign0.20.55Ambiguous0.40Likely Benign-0.24Likely Benign0.082Likely Benign1.90Neutral0.000Benign0.001Benign3.43Benign1.00Tolerated0.28070.4961100.4-30.03
c.3938C>T
P1313L
2D
AIThe SynGAP1 missense variant P1313L is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign status. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.970301Binding0.4520.9020.750-4.588Likely Benign0.097Likely BenignLikely Benign0.082Likely Benign1.90Neutral0.000Benign0.001Benign4.30Benign1.00Tolerated0.24890.6948-3-35.416.04
c.1496G>A
R499K
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant R499K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Only FATHMM predicts a pathogenic outcome. Stability‑based methods (FoldX, Rosetta, Foldetta, premPS) are inconclusive, providing no evidence for either direction. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also yields a benign prediction; Foldetta remains uncertain. Overall, the preponderance of evidence points to a benign effect for R499K, and this conclusion is consistent with the absence of any ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.071867Structured0.386723Uncertain0.8990.1460.0004.366Likely Benign0.091Likely BenignLikely Benign1.37Ambiguous0.10.53Ambiguous0.95Ambiguous-0.77Ambiguous0.248Likely Benign1.94Neutral0.001Benign0.008Benign-1.03Pathogenic1.00Tolerated0.35310.1881320.6-28.01
c.1040C>A
T347N
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T347N is listed in ClinVar with an uncertain significance (ClinVar ID 3672484.0) and is present in the gnomAD database (gnomAD ID 6‑33437945‑C‑A). Prediction tools that uniformly indicate a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, resolves to “Likely Benign” (3 benign vs. 1 pathogenic). High‑accuracy assessments are consistent: AlphaMissense‑Optimized is benign, the SGM‑Consensus is likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) is benign. Overall, the collective evidence points to a benign effect, aligning with the ClinVar designation of uncertain significance.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.268042Structured0.349915Uncertain0.9510.4340.000Uncertain 16-33437945-C-A95.58e-6-5.545Likely Benign0.165Likely BenignLikely Benign0.41Likely Benign0.10.46Likely Benign0.44Likely Benign-0.06Likely Benign0.059Likely Benign1.96Neutral0.001Benign0.001Benign1.67Pathogenic0.60Tolerated3.37250.10700.435900-2.813.00
c.819G>C
E273D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 E273D missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Prediction tools largely agree on a benign effect: SGM‑Consensus, REVEL, FoldX, Rosetta, Foldetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate benign or likely benign. Only FATHMM predicts a pathogenic outcome, while premPS remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts benign stability. Overall, the majority of evidence supports a benign impact for E273D, and this conclusion does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.071867Structured0.398918Uncertain0.8630.1960.125-1.811Likely Benign0.058Likely BenignLikely Benign0.26Likely Benign0.1-0.48Likely Benign-0.11Likely Benign-0.63Ambiguous0.094Likely Benign1.99Neutral0.004Benign0.010Benign2.00Pathogenic1.00Tolerated3.38180.17110.1859320.0-14.03223.122.10.20.00.00.1XPotentially BenignThe negatively charged residue Glu273, located in a β hairpin loop (res. Glu273-Lys278) that connects two anti-parallel β sheet strands, is replaced with another negatively charged residue, aspartate. Because the C2 domain loop faces the membrane surface, the potentially crucial role of the carboxylate group of Glu273 or Asp273 on SynGAP-membrane association cannot be fully explored via solvent-only simulations.As a minor note, the neighboring residue Arg272, which stacks with the indole ring of the Trp362 side chain and directly faces RasGTPase, forms a salt bridge more often with Asp273 than with the non-mutated Glu273 in the simulations. Regardless, due to the similar physicochemical properties of the WT and variant residues at the membrane interface, the residue swap is likely to be well tolerated.
c.819G>T
E273D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant E273D is listed in ClinVar as Benign (ClinVar ID 1471608.0) and is present in gnomAD (variant ID 6‑33437724‑G‑T). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while premPS is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is Likely Benign. High‑accuracy assessments are consistent: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus (majority vote) is benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) also predicts benign. No prediction contradicts the ClinVar benign status; overall, the evidence strongly supports that E273D is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.071867Structured0.398918Uncertain0.8630.1960.125Benign 16-33437724-G-T21.24e-6-1.811Likely Benign0.058Likely BenignLikely Benign0.26Likely Benign0.1-0.48Likely Benign-0.11Likely Benign-0.63Ambiguous0.092Likely Benign1.99Neutral0.004Benign0.010Benign2.00Pathogenic1.00Tolerated3.38180.17110.1859320.0-14.03223.122.10.20.00.00.1XPotentially BenignThe negatively charged residue Glu273, located in a β hairpin loop (res. Glu273-Lys278) that connects two anti-parallel β sheet strands, is replaced with another negatively charged residue, aspartate. Because the C2 domain loop faces the membrane surface, the potentially crucial role of the carboxylate group of Glu273 or Asp273 on SynGAP-membrane association cannot be fully explored via solvent-only simulations.As a minor note, the neighboring residue Arg272, which stacks with the indole ring of the Trp362 side chain and directly faces RasGTPase, forms a salt bridge more often with Asp273 than with the non-mutated Glu273 in the simulations. Regardless, due to the similar physicochemical properties of the WT and variant residues at the membrane interface, the residue swap is likely to be well tolerated.
c.3758C>A
A1253E
2D
AIThe SynGAP1 missense variant A1253E is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset predicts pathogenicity. High‑accuracy assessments corroborate this benign classification: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.661982Disordered0.391377Uncertain0.8810.5500.750-1.744Likely Benign0.166Likely BenignLikely Benign0.059Likely Benign2.03Neutral0.301Benign0.209Benign3.03Benign0.98Tolerated0.09480.17040-1-5.358.04
c.3929C>T
T1310M
2D
AIThe SynGAP1 missense variant T1310M is listed in ClinVar (ID 2160201.0) as Benign and is present in gnomAD (gnomAD ID 6‑33451803‑C‑T). All evaluated in‑silico predictors report a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence overwhelmingly supports a benign classification, which aligns with the ClinVar status and does not contradict it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.959076Binding0.3980.9040.750Benign 16-33451803-C-T171.05e-5-4.822Likely Benign0.117Likely BenignLikely Benign0.069Likely Benign2.19Neutral0.021Benign0.005Benign2.98Benign0.93Tolerated3.7750.11440.5397-1-12.630.09
c.1934T>A
F645Y
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant F645Y is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Functional prediction tools that agree on a benign effect include REVEL, Rosetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools with inconclusive results are FoldX (Uncertain) and premPS (Uncertain). High‑accuracy assessments show AlphaMissense‑Optimized predicting Benign, the SGM‑Consensus indicating Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) also predicting Benign. No tool predicts pathogenicity. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as the variant is not currently classified in ClinVar.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.046336Structured0.276445Uncertain0.9210.3250.000-3.544Likely Benign0.131Likely BenignLikely Benign0.52Ambiguous0.20.21Likely Benign0.37Likely Benign-0.61Ambiguous0.141Likely Benign2.40Neutral0.000Benign0.000Benign3.61Benign1.00Tolerated0.15060.218973-4.116.00
c.2009T>C
L670P
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L670P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all indicate benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. Stability‑based methods are inconclusive: FoldX, Rosetta, and the combined Foldetta output are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as likely benign, and Foldetta as uncertain. Overall, the majority of evidence supports a benign classification, and this is consistent with the absence of a ClinVar assertion; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.161087Structured0.090855Uncertain0.8120.3850.000-4.916Likely Benign0.237Likely BenignLikely Benign0.56Ambiguous0.31.83Ambiguous1.20Ambiguous-0.25Likely Benign0.211Likely Benign2.42Neutral1.000Probably Damaging0.996Probably Damaging3.41Benign0.26Tolerated0.35900.1474-3-3-5.4-16.04
c.1721T>A
L574Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L574Q resides in the GAP domain. ClinVar contains no entry for this variant, and it is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, Foldetta, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM; Rosetta’s assessment is uncertain. High‑accuracy methods give a consistent benign signal: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts benign. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.083462Structured0.026427Uncertain0.9270.2460.000-3.015Likely Benign0.196Likely BenignLikely Benign0.26Likely Benign0.20.52Ambiguous0.39Likely Benign-0.18Likely Benign0.327Likely Benign2.53Neutral0.998Probably Damaging0.937Probably Damaging-1.17Pathogenic0.65Tolerated0.11070.0888-2-2-7.314.97
c.3908G>A
G1303D
2D
AIThe SynGAP1 missense variant G1303D is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.871313Disordered0.886612Binding0.4290.8540.875-3.825Likely Benign0.329Likely BenignLikely Benign0.103Likely Benign2.64Neutral0.002Benign0.008Benign3.22Benign1.00Tolerated0.17840.14521-1-3.158.04
c.1427T>G
F476C
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant F476C is catalogued in gnomAD (ID 6‑33438459‑T‑G) but has no ClinVar entry. Functional prediction tools split in two groups: benign predictions come from REVEL, premPS, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions come from FoldX, Rosetta, Foldetta, polyPhen‑2 (HumDiv and HumVar), ESM1b, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as pathogenic, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a 2‑to‑2 split. Overall, seven tools predict pathogenicity versus six predicting benign, with no ClinVar evidence to contradict this assessment. Thus, the variant is most likely pathogenic based on the current computational predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.257454Structured0.397815Uncertain0.8210.2500.0006-33438459-T-G-9.270Likely Pathogenic0.745Likely PathogenicLikely Benign2.05Destabilizing0.12.62Destabilizing2.34Destabilizing-0.30Likely Benign0.280Likely Benign2.69Neutral1.000Probably Damaging0.999Probably Damaging3.46Benign0.83Tolerated3.40220.20510.1251-2-4-0.3-44.04
c.2543G>A
G848D
2D
AIThe SynGAP1 missense variant G848D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the evidence strongly supports a benign classification, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.563942Binding0.2870.8160.500-0.059Likely Benign0.318Likely BenignLikely Benign0.121Likely Benign2.94Neutral0.008Benign0.019Benign2.95Benign0.81Tolerated0.17020.13921-1-3.158.04

Found 8751 rows. Show 800 rows per page. Page 11/11 « Previous | Next »