SynGap Missense Server

Table of SynGAP1 Isoform α2 (UniProt Q96PV0-1) Missense Variants.

c.dna Variant SGM Consensus Domain and Structure information: based on WT protein Annotated databases Deep learning-based pathogenicity predictions Folding stability-based pathogenicity predictions Sequence/structure-based pathogenicity predictions Phase Separation Evolutionary/physical properties Molecular Dynamics-based analysis DOI
Domain IUPred2 ANCHOR2 AlphaFold MobiDB PhosphoSitePlus ClinVar gnomAD ESM1b AlphaMissense FoldX Rosetta Foldetta PremPS REVEL PROVEAN PolyPhen-2 HumDiv PolyPhen-2 HumVar FATHMM SIFT PSMutPred PAM Physical SASA Normalized B-factor backbone Normalized B-factor sidechain SynGAP Structural Annotation
Score Prediction Score Prediction pLDDT disorder disorder LTP HTP KL PTM Clinical Status Review Subm. ID Allele count Allele freq. LLR score Prediction Pathogenicity Class Optimized Average ΔΔG Prediction StdDev ΔΔG Prediction ΔΔG Prediction ΔΔG Prediction Score Prediction Score Prediction pph2_prob Prediction pph2_prob Prediction Nervous System Score Prediction Prediction Status Conservation Sequences IP RF SP RF Prediction PAM250 PAM120 Hydropathy Δ MW Δ Average Δ Δ StdDev Δ StdDev Secondary Tertiary bonds Inside out GAP-Ras interface At membrane No effect MD Alert Verdict Description
c.637A>G
I213V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 I213V missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). No tool predicts a pathogenic outcome. Predictions that are inconclusive are FoldX, Rosetta, Foldetta, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, while Foldetta’s stability analysis is uncertain. Overall, the evidence strongly favors a benign classification, and this is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.158265Structured0.372201Uncertain0.8500.2950.125-6.133Likely Benign0.364AmbiguousLikely Benign0.67Ambiguous0.20.58Ambiguous0.63Ambiguous0.47Likely Benign0.413Likely Benign-0.69Neutral0.128Benign0.048Benign5.82Benign0.10Tolerated0.10080.295943-0.3-14.03
c.1154C>T
S385L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S385L is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33438059‑C‑T). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) classifies the variant as “Likely Benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign; the SGM‑Consensus itself is benign; and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts benign. Overall, the majority of computational evidence indicates the variant is most likely benign, which does not contradict the current ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.733139Disordered0.425480Uncertain0.3410.9250.750Uncertain 26-33438059-C-T94.60e-5-6.018Likely Benign0.167Likely BenignLikely Benign0.16Likely Benign0.10.08Likely Benign0.12Likely Benign-0.26Likely Benign0.304Likely Benign-0.68Neutral0.829Possibly Damaging0.706Possibly Damaging4.63Benign0.01Affected4.3230.18970.6244-3-24.626.08244.6-50.10.00.6-0.10.1UncertainSer385 is located in the Gly-rich Ω loop (res. Pro364-Pro398) between two anti-parallel β sheet strands (res. Thr359-Pro364, res. Ala399-Ile411). Because the Ω loop is assumed to directly interact with the membrane, it moves arbitrarily throughout the WT solvent simulations. The Ω loop potentially plays a crucial role in the SynGAP-membrane complex association, stability, and dynamics. However, this aspect cannot be fully addressed through solvent simulations alone.Ω loops are known to play major roles in protein functions that require flexibility, and thus hydrophobic residues like leucine are rarely tolerated. Although no negative structural effects are observed in the variant simulations, Leu385 may exert drastic effects on the SynGAP-membrane complex dynamics and stability. However, since the effects on Gly-rich Ω loop dynamics can only be studied through the SynGAP-membrane complex, no definite conclusions can be drawn.
c.136C>A
P46T
2D
AIThe SynGAP1 missense variant P46T is reported in ClinVar as “Not submitted” and is not present in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, all of which classify the change as benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT uniformly predict a pathogenic impact. AlphaMissense‑Default remains uncertain, and no Foldetta stability assessment is available. High‑accuracy methods give a consistent benign signal: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports “Likely Benign,” and Foldetta data are missing. Overall, the majority of reliable predictors and the consensus analysis indicate that P46T is most likely benign, and this conclusion does not contradict the ClinVar status, which contains no pathogenic assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.390993Structured0.433588Uncertain0.5490.7410.375-4.329Likely Benign0.383AmbiguousLikely Benign0.092Likely Benign-0.68Neutral0.909Possibly Damaging0.901Possibly Damaging4.13Benign0.00Affected0.21940.64000-10.93.99
c.136C>G
P46A
2D
AIThe SynGAP1 missense variant P46A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for P46A, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.390993Structured0.433588Uncertain0.5490.7410.375-4.811Likely Benign0.270Likely BenignLikely Benign0.077Likely Benign-0.68Neutral0.805Possibly Damaging0.857Possibly Damaging4.16Benign0.00Affected0.39870.56961-13.4-26.04
c.1520A>G
K507R
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant K507R is not listed in ClinVar (ClinVar status: not reported) but is present in gnomAD (gnomAD ID 6-33438552-A-G). Prediction tools that agree on a benign effect include FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are REVEL, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. The high‑accuracy AlphaMissense‑Optimized score is benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) is benign. No prediction or folding stability result is missing or inconclusive. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which has no pathogenic annotation for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.019401Structured0.262601Uncertain0.8850.2220.0006-33438552-A-G16.20e-7-7.363In-Between0.085Likely BenignLikely Benign-0.08Likely Benign0.10.38Likely Benign0.15Likely Benign0.36Likely Benign0.503Likely Pathogenic-0.68Neutral0.992Probably Damaging0.980Probably Damaging-1.48Pathogenic0.27Tolerated3.37350.31550.057923-0.628.01
c.2204G>A
S735N
2D
AIThe SynGAP1 missense variant S735N is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.916840Disordered0.412174Uncertain0.2900.7520.875-6.697Likely Benign0.142Likely BenignLikely Benign0.068Likely Benign-0.68Neutral0.400Benign0.138Benign2.65Benign0.18Tolerated0.13750.382711-2.727.03
c.2213G>C
S738T
2D
AIThe SynGAP1 missense variant S738T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the variant as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.441162Uncertain0.2840.8270.875-3.926Likely Benign0.062Likely BenignLikely Benign0.039Likely Benign-0.68Neutral0.010Benign0.010Benign2.73Benign0.51Tolerated0.13360.4227110.114.03
c.2236G>C
V746L
2D
AIThe SynGAP1 missense variant V746L is catalogued in gnomAD (ID 6‑33441701‑G‑C) but has no ClinVar entry. Across a broad panel of in silico predictors, every tool reports a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool in the set predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available for this variant. Taken together, the computational evidence overwhelmingly supports a benign effect, and this conclusion does not conflict with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.808535Disordered0.576597Binding0.3360.8670.8756-33441701-G-C16.19e-7-3.260Likely Benign0.086Likely BenignLikely Benign0.015Likely Benign-0.68Neutral0.002Benign0.003Benign2.82Benign0.08Tolerated4.3220.08960.506512-0.414.03
c.2236G>T
V746L
2D
AIThe SynGAP1 missense variant V746L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized scores the variant as benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports it as Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that V746L is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.808535Disordered0.576597Binding0.3360.8670.875-3.260Likely Benign0.086Likely BenignLikely Benign0.015Likely Benign-0.68Neutral0.002Benign0.003Benign2.82Benign0.08Tolerated4.3220.08960.506512-0.414.03
c.2278A>C
M760L
2D
AIThe SynGAP1 missense variant M760L is not reported in ClinVar and is absent from gnomAD. Prediction tools that assess pathogenicity uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts a pathogenic outcome. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign effect, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.541878Disordered0.893402Binding0.3460.8650.375-2.260Likely Benign0.134Likely BenignLikely Benign0.145Likely Benign-0.68Neutral0.065Benign0.033Benign2.69Benign0.15Tolerated0.18020.4805421.9-18.03
c.2278A>T
M760L
2D
AIThe SynGAP1 missense variant M760L is not reported in ClinVar and is absent from gnomAD. Prediction tools that assess pathogenicity uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts a pathogenic outcome. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign effect, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.541878Disordered0.893402Binding0.3460.8650.375-2.260Likely Benign0.134Likely BenignLikely Benign0.145Likely Benign-0.68Neutral0.065Benign0.033Benign2.69Benign0.15Tolerated0.18020.4805421.9-18.03
c.2321C>G
A774G
2D
AIThe SynGAP1 missense variant A774G is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.450668Structured0.905168Binding0.3360.8970.250-3.129Likely Benign0.099Likely BenignLikely Benign0.056Likely Benign-0.68Neutral0.135Benign0.152Benign4.16Benign0.22Tolerated0.23920.543610-2.2-14.03
c.244C>A
L82M
2D
AIThe SynGAP1 missense variant L82M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), which collectively classify the variant as likely benign. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. The high‑accuracy AlphaMissense‑Optimized prediction is uncertain, and no Foldetta stability result is available. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of a ClinVar assertion; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.637480Disordered0.517720Binding0.2840.8900.375-4.608Likely Benign0.888Likely PathogenicAmbiguous0.082Likely Benign-0.68Neutral0.939Possibly Damaging0.114Benign3.67Benign0.00Affected0.07440.327842-1.918.03
c.2588T>A
L863Q
2D
AIThe SynGAP1 missense variant L863Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic effect. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence from multiple independent predictors points to a benign classification for L863Q, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.525368Disordered0.594839Binding0.2670.7950.250-6.334Likely Benign0.279Likely BenignLikely Benign0.135Likely Benign-0.68Neutral0.999Probably Damaging0.977Probably Damaging4.02Benign0.23Tolerated0.11000.1305-2-2-7.314.97
c.2696T>A
I899N
2D
AIThe SynGAP1 missense variant I899N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions come from polyPhen‑2 HumDiv and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, SGM‑Consensus is likely benign, and Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign effect for I899N, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.443727Uncertain0.2920.9280.375-3.328Likely Benign0.469AmbiguousLikely Benign0.058Likely Benign-0.68Neutral0.611Possibly Damaging0.140Benign2.76Benign0.00Affected0.09330.0470-2-3-8.00.94
c.2819G>A
G940D
2D
AIThe SynGAP1 missense variant G940D is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33443371‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Two tools, AlphaMissense‑Default and ESM1b, return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because it receives two benign and two uncertain votes, and Foldetta’s protein‑folding stability analysis is unavailable. Overall, the balance of evidence favors a benign classification, and this conclusion does not contradict the ClinVar status, which is currently unreported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.889439Disordered0.920635Binding0.3830.9020.6256-33443371-G-A63.72e-6-7.311In-Between0.397AmbiguousLikely Benign0.076Likely Benign-0.68Neutral0.770Possibly Damaging0.583Possibly Damaging2.72Benign0.17Tolerated3.7750.18370.2252-11-3.158.04
c.2891A>G
H964R
2D
AIThe SynGAP1 missense variant H964R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b. The SGM‑Consensus, which is a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign (3 benign vs. 1 pathogenic). High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-8.275Likely Pathogenic0.163Likely BenignLikely Benign0.129Likely Benign-0.68Neutral0.000Benign0.000Benign4.19Benign0.05Affected0.22370.346720-1.319.05
c.3082C>G
L1028V
2D
AIThe SynGAP1 missense variant L1028V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign. Foldetta results are not available, so they do not influence the assessment. Overall, the majority of computational evidence indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.899122Disordered0.995137Binding0.3640.7300.500-3.992Likely Benign0.217Likely BenignLikely Benign0.042Likely Benign-0.68Neutral0.737Possibly Damaging0.376Benign2.74Benign0.26Tolerated0.13280.2715210.4-14.03
c.3148G>A
G1050R
2D
AIThe SynGAP1 missense variant G1050R is catalogued in gnomAD (ID 6‑33443700‑G‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. Only FATHMM predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields a benign verdict, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.906802Binding0.3700.9280.8756-33443700-G-A31.86e-6-6.637Likely Benign0.349AmbiguousLikely Benign0.045Likely Benign-0.68Neutral0.009Benign0.008Benign2.48Pathogenic0.06Tolerated3.7750.09390.4532-2-3-4.199.14
c.3148G>C
G1050R
2D
AIThe SynGAP1 missense variant G1050R is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. Only FATHMM predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, and the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign majority vote. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact; this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.906802Binding0.3700.9280.875-6.637Likely Benign0.349AmbiguousLikely Benign0.045Likely Benign-0.68Neutral0.009Benign0.008Benign2.48Pathogenic0.06Tolerated3.7750.09390.4532-2-3-4.199.14
c.3181G>A
G1061S
2D
AIThe SynGAP1 missense variant G1061S is listed in ClinVar (ID 3571724.0) with an uncertain significance designation and is not reported in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only SIFT indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta stability analysis is unavailable. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods supports a benign classification for G1061S, which is consistent with its ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.926729Binding0.3940.9230.875Uncertain 1-4.891Likely Benign0.079Likely BenignLikely Benign0.283Likely Benign-0.68Neutral0.004Benign0.004Benign4.00Benign0.00Affected0.24040.530010-0.430.03
c.3205C>G
Q1069E
2D
AIThe SynGAP1 missense variant Q1069E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.981477Binding0.3330.9060.875-5.165Likely Benign0.322Likely BenignLikely Benign0.107Likely Benign-0.68Neutral0.451Benign0.266Benign2.76Benign0.33Tolerated0.14600.3127220.00.98
c.3349G>C
G1117R
2D
AIThe SynGAP1 missense variant G1117R is not reported in ClinVar and is absent from gnomAD. Consensus among most in silico predictors is benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Optimized all classify the change as tolerated or benign. No tool predicts pathogenicity. Two predictors (ESM1b and AlphaMissense‑Default) return uncertain results, but these do not alter the overall benign consensus. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive due to a 2‑to‑2 split, and Foldetta data are unavailable. Consequently, the variant is most likely benign, and this assessment does not contradict the absence of a ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.882776Disordered0.853192Binding0.3230.9140.750-7.132In-Between0.519AmbiguousLikely Benign0.253Likely Benign-0.68Neutral0.006Benign0.008Benign4.62Benign0.08Tolerated0.09370.4542-3-2-4.199.14
c.359G>T
G120V
2D
AIThe SynGAP1 missense variant G120V is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is not contradicted by any ClinVar status (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.659993Binding0.3590.8870.750-4.571Likely Benign0.107Likely BenignLikely Benign0.036Likely Benign-0.68Neutral0.000Benign0.000Benign4.28Benign0.19Tolerated0.13210.3883-1-34.642.08
c.3835G>C
A1279P
2D
AIThe SynGAP1 missense variant A1279P is not reported in ClinVar and is absent from gnomAD. In silico prediction tools that assess sequence conservation and structural impact (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized) all classify the change as benign. No tool in the dataset predicts pathogenicity. High‑accuracy consensus methods reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability predictor, was not available for this variant. Overall, the collective evidence strongly suggests the variant is most likely benign, and this conclusion is consistent with the lack of a ClinVar classification—there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.842060Disordered0.814139Binding0.4850.7240.750-3.999Likely Benign0.076Likely BenignLikely Benign0.167Likely Benign-0.68Neutral0.299Benign0.087Benign2.67Benign0.15Tolerated0.15890.39381-1-3.426.04
c.3841G>A
A1281T
2D
AIThe SynGAP1 missense variant A1281T is reported in gnomAD (6‑33447889‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only polyPhen‑2 HumDiv predicts it as pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the available predictions points to a benign effect, and this is not in conflict with the ClinVar status, which is currently unclassified.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.823549Disordered0.821556Binding0.4340.7210.8756-33447889-G-A16.44e-7-4.366Likely Benign0.074Likely BenignLikely Benign0.090Likely Benign-0.68Neutral0.818Possibly Damaging0.355Benign2.67Benign0.16Tolerated4.3240.14790.564401-2.530.03
c.523C>G
Q175E
2D
AIThe SynGAP1 missense variant Q175E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Consensus from multiple in‑silico predictors shows a benign bias: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, whereas ESM1b predicts it to be pathogenic. AlphaMissense‑Default remains uncertain. High‑accuracy assessment further supports a benign outcome: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign, and Foldetta stability analysis is unavailable. Consequently, the overall evidence points to a benign effect for Q175E. This conclusion is consistent with the absence of a ClinVar assertion, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.653063Disordered0.474689Uncertain0.3670.6180.375-11.035Likely Pathogenic0.502AmbiguousLikely Benign0.149Likely Benign-0.68Neutral0.118Benign0.039Benign4.17Benign0.40Tolerated0.13510.2028220.00.98
c.1150G>A
G384S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G384S (gnomAD ID 6-33438055‑G‑A) is listed in ClinVar with an uncertain significance. Functional prediction tools cluster into two groups: benign predictions from REVEL, premPS, PROVEAN, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized; pathogenic predictions from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign outcome. High‑accuracy assessments further support benignity: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus (majority vote) is likely benign, and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, is inconclusive. No evidence from FoldX or Rosetta alone is available. Overall, the preponderance of evidence points to a benign effect, which does not contradict the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.728858Disordered0.427831Uncertain0.3230.9340.750Uncertain 16-33438055-G-A16.22e-7-5.243Likely Benign0.090Likely BenignLikely Benign1.92Ambiguous0.21.66Ambiguous1.79Ambiguous0.19Likely Benign0.315Likely Benign-0.67Neutral0.980Probably Damaging0.968Probably Damaging1.33Pathogenic0.04Affected4.3220.29050.492410-0.430.03202.4-49.80.51.0-0.20.0UncertainGly384 is located in the Gly-rich Ω loop (res. Pro364-Pro398) between two anti-parallel β sheet strands (res. Thr359-Pro364, res. Ala399-Ile411). Because the Ω loop is assumed to directly interact with the membrane, it moves arbitrarily throughout the WT solvent simulations. The Ω loop potentially plays a crucial role in the SynGAP-membrane complex association, stability, and dynamics. However, this aspect cannot be fully addressed through solvent simulations alone.Ω loops are known to play major roles in protein functions that require flexibility, and so they are rich in glycines, prolines, and, to a lesser extent, small hydrophilic residues to ensure maximum flexibility. Thus, the variant’s Ser384 is potentially tolerated in the Ω loop, although the hydroxyl group of Ser384 forms various hydrogen bonds with several other loop residues in the variant simulations. However, since the effects on Gly-rich Ω loop dynamics can only be studied through the SynGAP-membrane complex, no definite conclusions can be drawn.
c.1163G>A
G388D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G388D is reported in gnomAD (variant ID 6-33438068‑G‑A) but has no entry in ClinVar. Functional prediction tools cluster into two groups: benign predictions come from premPS, PROVEAN, and AlphaMissense‑Optimized; pathogenic predictions arise from SGM‑Consensus, REVEL, FoldX, Rosetta, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments reinforce this split: AlphaMissense‑Optimized indicates a benign effect, whereas the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—labels the variant as likely pathogenic; Foldetta, integrating FoldX‑MD and Rosetta outputs, also predicts a pathogenic impact on protein stability. Taken together, the preponderance of evidence from both general and high‑accuracy predictors points to a pathogenic effect for G388D, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicC20.736850Disordered0.420316Uncertain0.3190.8270.7506-33438068-G-A-8.416Likely Pathogenic0.574Likely PathogenicLikely Benign5.56Destabilizing7.33.08Destabilizing4.32Destabilizing0.42Likely Benign0.618Likely Pathogenic-0.67Neutral0.994Probably Damaging0.986Probably Damaging1.32Pathogenic0.04Affected4.3230.19230.1624-11-3.158.04
c.2219G>A
R740Q
2D
AIThe SynGAP1 missense variant R740Q is listed in ClinVar with an “Uncertain” status and is present in gnomAD (variant ID 6‑33441684‑G‑A). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no reported result for this variant, so it does not influence the assessment. Overall, the majority of predictions indicate that R740Q is most likely benign, which is consistent with the ClinVar “Uncertain” classification and does not contradict it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.771762Disordered0.475392Uncertain0.2690.8490.875Uncertain 16-33441684-G-A42.48e-6-5.195Likely Benign0.078Likely BenignLikely Benign0.102Likely Benign-0.67Neutral0.999Probably Damaging0.881Possibly Damaging2.60Benign0.08Tolerated4.3220.34540.2203111.0-28.06
c.2243T>G
L748R
2D
AIThe SynGAP1 missense variant L748R is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33441708‑T‑G). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, SGM‑Consensus is likely benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict the current ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.611637Binding0.3390.8630.750Conflicting 26-33441708-T-G31.86e-6-3.331Likely Benign0.245Likely BenignLikely Benign0.055Likely Benign-0.67Neutral0.912Possibly Damaging0.448Possibly Damaging2.73Benign0.02Affected4.3220.13420.0888-3-2-8.343.03
c.2413C>A
L805M
2D
AIThe SynGAP1 missense variant L805M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and no Foldetta stability data are available. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical databases.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.775545Disordered0.827669Binding0.3410.9030.625-4.229Likely Benign0.133Likely BenignLikely Benign0.034Likely Benign-0.67Neutral0.029Benign0.033Benign2.39Pathogenic0.00Affected0.09110.386742-1.918.03
c.2422G>A
V808I
2D
AIThe SynGAP1 missense variant V808I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Pathogenic predictions come from polyPhen‑2 HumDiv, SIFT, and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign and the SGM‑Consensus (majority vote) is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.699094Disordered0.856438Binding0.2890.9030.500-4.190Likely Benign0.151Likely BenignLikely Benign0.051Likely Benign-0.67Neutral0.659Possibly Damaging0.191Benign2.33Pathogenic0.00Affected0.09350.4282430.314.03
c.2573G>A
S858N
2D
AIThe SynGAP1 missense variant S858N is listed in ClinVar with an “Uncertain” status and is present in gnomAD (variant ID 6‑33443125‑G‑A). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumDiv, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all indicate benign. In contrast, polyPhen‑2 HumVar and SIFT predict pathogenicity, but these two tools are in the minority. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.482724Uncertain0.3050.8330.375Uncertain 16-33443125-G-A21.24e-6-4.311Likely Benign0.121Likely BenignLikely Benign0.107Likely Benign-0.67Neutral0.448Benign0.846Possibly Damaging4.13Benign0.02Affected3.7750.15270.477211-2.727.03
c.2613C>A
H871Q
2D
AIThe SynGAP1 missense variant H871Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign classification, and this conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.679301Binding0.2790.8580.250-4.049Likely Benign0.140Likely BenignLikely Benign0.061Likely Benign-0.67Neutral0.255Benign0.113Benign2.69Benign0.17Tolerated3.8830.13840.335703-0.3-9.01
c.2613C>G
H871Q
2D
AIThe SynGAP1 missense variant H871Q is reported in gnomAD (ID 6‑33443165‑C‑G) and has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability predictor, was not available for this variant. Overall, the evidence strongly supports a benign impact. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.679301Binding0.2790.8580.2506-33443165-C-G16.20e-7-4.049Likely Benign0.140Likely BenignLikely Benign0.061Likely Benign-0.67Neutral0.255Benign0.113Benign2.69Benign0.17Tolerated3.8830.13840.335703-0.3-9.01
c.2632A>G
T878A
2D
AIThe SynGAP1 missense variant T878A is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). No tool in the dataset predicts a pathogenic outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign,” and a Foldetta stability analysis is unavailable. Overall, the evidence strongly supports a benign classification, and this does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.622677Disordered0.628767Binding0.2880.8780.250Uncertain 2-2.154Likely Benign0.081Likely BenignLikely Benign0.088Likely Benign-0.67Neutral0.003Benign0.006Benign2.73Benign0.18Tolerated3.7750.43120.4625102.5-30.03
c.2677C>G
Q893E
2D
AIThe SynGAP1 missense variant Q893E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that assess sequence conservation and structural impact all converge on a benign interpretation: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. No tool in the dataset indicates pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is labeled “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence strongly supports a benign effect, and this conclusion is consistent with the absence of any ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.447267Uncertain0.3100.9250.750-3.888Likely Benign0.296Likely BenignLikely Benign0.088Likely Benign-0.67Neutral0.421Benign0.181Benign2.76Benign0.06Tolerated0.15350.2555220.00.98
c.2950A>C
K984Q
2D
AIThe SynGAP1 missense variant K984Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.951648Binding0.2880.8950.750-2.932Likely Benign0.612Likely PathogenicLikely Benign0.083Likely Benign-0.67Neutral0.905Possibly Damaging0.637Possibly Damaging2.66Benign0.00Affected0.50540.1240Weaken110.4-0.04
c.313T>G
S105A
2D
AIThe SynGAP1 missense variant S105A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect. The predictions do not contradict ClinVar status, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.669201Binding0.3640.8700.625-3.779Likely Benign0.115Likely BenignLikely Benign0.046Likely Benign-0.67Neutral0.012Benign0.002Benign4.11Benign0.00Affected0.52990.4214Weaken112.6-16.00
c.31G>T
G11W
2D
AIThe SynGAP1 missense variant G11W is catalogued in gnomAD (ID 6‑33420295‑G‑T) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions come from polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.444081Structured0.501027Binding0.3480.9150.3756-33420295-G-T-5.819Likely Benign0.403AmbiguousLikely Benign0.096Likely Benign-0.67Neutral0.959Probably Damaging0.318Benign3.87Benign0.00Affected4.3210.07470.4731-2-7-0.5129.16
c.3223C>A
Q1075K
2D
AIThe SynGAP1 missense variant Q1075K (ClinVar ID 2762879.0) is listed as “Uncertain” in ClinVar and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is “Likely Benign” because three of the four contributing tools predict benign. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote) as benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.988305Binding0.3540.8940.750Uncertain 1-5.135Likely Benign0.728Likely PathogenicLikely Benign0.134Likely Benign-0.67Neutral0.963Probably Damaging0.959Probably Damaging2.75Benign1.00Tolerated3.7750.18980.441111-0.40.04
c.3353G>C
S1118T
2D
AIThe SynGAP1 missense variant S1118T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.828802Binding0.3100.9190.750-6.063Likely Benign0.067Likely BenignLikely Benign0.196Likely Benign-0.67Neutral0.790Possibly Damaging0.433Benign5.18Benign0.10Tolerated0.20660.5587110.114.03
c.3538C>A
L1180I
2D
AIThe SynGAP1 missense variant L1180I is not reported in ClinVar and has no gnomAD entry. Prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions come from polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, indicates a likely benign effect. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for the variant, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.626927Disordered0.559845Binding0.5910.6720.250-4.553Likely Benign0.697Likely PathogenicLikely Benign0.086Likely Benign-0.67Neutral0.856Possibly Damaging0.578Possibly Damaging2.69Benign0.00Affected0.08250.2708220.70.00
c.3968C>G
P1323R
2D
AIThe SynGAP1 missense variant P1323R is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that P1323R is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.901269Disordered0.907659Binding0.4890.8140.875-5.785Likely Benign0.159Likely BenignLikely Benign0.074Likely Benign-0.67Neutral0.002Benign0.003Benign3.82Benign0.00Affected0.17250.30150-2-2.959.07
c.1127G>T
G376V
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant G376V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools show a split assessment: benign predictions come from premPS, PROVEAN, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized, while pathogenic predictions arise from REVEL, FoldX, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. The consensus score from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign, matching the majority of individual benign calls. High‑accuracy methods give mixed results: AlphaMissense‑Optimized predicts benign, SGM Consensus predicts benign, whereas Foldetta (integrating FoldX‑MD and Rosetta) predicts pathogenic. No prediction is missing or inconclusive. Overall, the balance of evidence leans toward a benign effect; this is consistent with the lack of ClinVar annotation and gnomAD presence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.680603Disordered0.428979Uncertain0.3260.8690.625-6.242Likely Benign0.120Likely BenignLikely Benign4.84Destabilizing0.8-0.81Ambiguous2.02Destabilizing-0.18Likely Benign0.541Likely Pathogenic-0.66Neutral1.000Probably Damaging0.998Probably Damaging1.32Pathogenic0.01Affected0.15940.3525-1-34.642.08
c.1609G>T
A537S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A537S is reported in gnomAD (6-33438852-G-T) and has no ClinVar entry. Consensus from multiple in silico predictors indicates a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all score benign, while polyPhen‑2 (HumDiv and HumVar) and FATHMM predict pathogenicity. When predictions are grouped, the majority of tools (ten) support benign, whereas three tools support pathogenic. High‑accuracy assessments further reinforce the benign interpretation: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also predicts benign. Consequently, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.116183Structured0.037313Uncertain0.9280.3620.0006-33438852-G-T16.20e-7-3.602Likely Benign0.095Likely BenignLikely Benign0.28Likely Benign0.00.46Likely Benign0.37Likely Benign0.28Likely Benign0.206Likely Benign-0.66Neutral0.528Possibly Damaging0.592Possibly Damaging-1.25Pathogenic0.60Tolerated3.37350.27290.443111-2.616.00
c.200T>A
L67Q
2D
AIThe SynGAP1 missense variant L67Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.458154Structured0.473668Uncertain0.4280.7610.125-3.948Likely Benign0.687Likely PathogenicLikely Benign0.115Likely Benign-0.66Neutral0.943Possibly Damaging0.766Possibly Damaging4.10Benign0.00Affected0.08610.0719-2-2-7.314.97
c.2390C>T
P797L
2D
AIThe SynGAP1 missense variant P797L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.926919Disordered0.449970Uncertain0.5610.9020.875-5.631Likely Benign0.072Likely BenignLikely Benign0.033Likely Benign-0.66Neutral0.818Possibly Damaging0.637Possibly Damaging4.23Benign0.40Tolerated0.25500.6538-3-35.416.04
c.2478C>A
D826E
2D
AIThe SynGAP1 missense variant D826E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, SGM‑Consensus as Likely Benign, and Foldetta results are unavailable. Overall, the balance of evidence leans toward a benign interpretation, with no conflict with ClinVar status because no ClinVar assertion exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.666105Disordered0.627309Binding0.3270.8860.625-4.172Likely Benign0.859Likely PathogenicAmbiguous0.164Likely Benign-0.66Neutral0.997Probably Damaging0.994Probably Damaging2.92Benign0.56Tolerated0.17950.7687320.014.03
c.2478C>G
D826E
2D
AIThe SynGAP1 missense variant D826E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, SGM‑Consensus as likely benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.666105Disordered0.627309Binding0.3270.8860.625-4.172Likely Benign0.859Likely PathogenicAmbiguous0.164Likely Benign-0.66Neutral0.997Probably Damaging0.994Probably Damaging2.92Benign0.56Tolerated0.17950.7687320.014.03
c.2593G>C
A865P
2D
AIThe SynGAP1 missense variant A865P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.521092Disordered0.626222Binding0.2710.7880.250-4.178Likely Benign0.139Likely BenignLikely Benign0.077Likely Benign-0.66Neutral0.918Possibly Damaging0.697Possibly Damaging2.67Benign0.27Tolerated0.17070.46901-1-3.426.04
c.2662G>T
A888S
2D
AIThe SynGAP1 missense variant A888S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect. The variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.575860Binding0.3520.9280.625-3.580Likely Benign0.082Likely BenignLikely Benign0.034Likely Benign-0.66Neutral0.017Benign0.025Benign2.64Benign0.00Affected0.26610.562611-2.616.00
c.2898C>A
H966Q
2D
AIThe SynGAP1 missense variant H966Q is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that H966Q is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.750-5.662Likely Benign0.100Likely BenignLikely Benign0.113Likely Benign-0.66Neutral0.748Possibly Damaging0.232Benign4.06Benign0.45Tolerated0.20580.391430-0.3-9.01
c.2898C>G
H966Q
2D
AIThe SynGAP1 missense variant H966Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.750-5.662Likely Benign0.100Likely BenignLikely Benign0.113Likely Benign-0.66Neutral0.748Possibly Damaging0.232Benign4.06Benign0.45Tolerated0.20580.391430-0.3-9.01
c.298T>A
Y100N
2D
AIThe SynGAP1 missense variant Y100N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.699094Disordered0.675421Binding0.3410.8800.625-2.579Likely Benign0.109Likely BenignLikely Benign0.183Likely Benign-0.66Neutral0.675Possibly Damaging0.099Benign4.23Benign0.00Affected0.24870.0373-2-2-2.2-49.07
c.3192G>C
Q1064H
2D
AIThe SynGAP1 missense variant Q1064H is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. The Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence—including high‑accuracy tools—points to a benign effect, and this conclusion does not contradict the current ClinVar “Uncertain” status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875Uncertain 1-4.576Likely Benign0.162Likely BenignLikely Benign0.063Likely Benign-0.66Neutral0.938Possibly Damaging0.596Possibly Damaging4.15Benign0.05Affected0.24670.4243300.39.01
c.3192G>T
Q1064H
2D
AIThe SynGAP1 missense variant Q1064H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for Q1064H, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875-4.576Likely Benign0.162Likely BenignLikely Benign0.063Likely Benign-0.66Neutral0.938Possibly Damaging0.596Possibly Damaging4.15Benign0.05Affected0.24670.4243300.39.01
c.3271C>A
L1091I
2D
AIThe SynGAP1 missense variant L1091I is reported in gnomAD (ID 6‑33443823‑C‑A) but has no ClinVar entry. Across the available in‑silico predictors, every tool classified the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all returned benign scores. No tool predicted pathogenicity, so the pathogenic‑prediction group is empty. High‑accuracy assessments reinforce this benign view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available for this variant. Overall, the computational evidence strongly supports a benign effect, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.924947Disordered0.984454Binding0.3760.8891.0006-33443823-C-A-4.304Likely Benign0.273Likely BenignLikely Benign0.057Likely Benign-0.66Neutral0.186Benign0.055Benign2.55Benign0.13Tolerated3.7750.10730.3911220.70.00
c.3403A>C
K1135Q
2D
AIThe SynGAP1 missense variant K1135Q has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only AlphaMissense‑Default predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as Likely Benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.790969Binding0.3030.8890.875-4.622Likely Benign0.566Likely PathogenicLikely Benign0.171Likely Benign-0.66Neutral0.099Benign0.150Benign5.43Benign0.07Tolerated0.50160.1356Weaken110.4-0.04
c.1112G>C
S371T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S371T is not reported in ClinVar and is absent from gnomAD. All available in silico predictors classify the substitution as benign: REVEL, FoldX, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). No tool predicts pathogenicity. High‑accuracy assessments concur: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields Likely Benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also reports a benign effect. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.444081Structured0.432086Uncertain0.2940.7460.375-4.512Likely Benign0.072Likely BenignLikely Benign0.38Likely Benign0.1-0.27Likely Benign0.06Likely Benign0.05Likely Benign0.173Likely Benign-0.65Neutral0.213Benign0.067Benign4.64Benign0.22Tolerated0.22450.6462110.114.03
c.1130T>C
M377T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M377T is reported in gnomAD (variant ID 6‑33438035‑T‑C) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. Uncertain results are reported for FoldX, Rosetta, Foldetta, and premPS. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as Likely Benign, and Foldetta as Uncertain. Overall, the majority of evidence points to a benign effect for M377T, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.675549Disordered0.431183Uncertain0.3240.8840.6256-33438035-T-C51.17e-5-1.881Likely Benign0.090Likely BenignLikely Benign0.90Ambiguous0.41.95Ambiguous1.43Ambiguous0.59Ambiguous0.245Likely Benign-0.65Neutral0.000Benign0.002Benign5.47Benign0.05Affected4.32120.30640.3267-1-1-2.6-30.09
c.175C>A
L59M
2D
AIThe SynGAP1 missense variant L59M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evaluated predictors lean toward a benign interpretation. Consequently, the variant is most likely benign based on current computational evidence, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.212910Structured0.484882Uncertain0.5100.6680.000-3.394Likely Benign0.618Likely PathogenicLikely Benign0.088Likely Benign-0.65Neutral0.824Possibly Damaging0.910Probably Damaging3.30Benign0.00Affected0.07720.331142-1.918.03
c.2671C>G
L891V
2D
AIThe SynGAP1 missense variant L891V is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are unavailable, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.712013Disordered0.505861Binding0.3050.9230.750-4.992Likely Benign0.094Likely BenignLikely Benign0.044Likely Benign-0.65Neutral0.057Benign0.032Benign2.72Benign0.70Tolerated0.16140.2945210.4-14.03
c.2705C>G
A902G
2D
AIThe SynGAP1 missense variant A902G is not listed in ClinVar and has no entry in gnomAD, indicating no reported clinical classification or population frequency data. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only SIFT predicts a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, SGM‑Consensus is benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) is unavailable for this variant. Overall, the consensus of available predictions points to a benign impact, with no conflict with ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.517703Binding0.3190.9190.375-4.046Likely Benign0.104Likely BenignLikely Benign0.020Likely Benign-0.65Neutral0.004Benign0.008Benign2.69Benign0.03Affected0.21770.446110-2.2-14.03
c.2977C>A
P993T
2D
AIThe SynGAP1 missense variant P993T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.923979Binding0.3190.9080.750-4.444Likely Benign0.061Likely BenignLikely Benign0.053Likely Benign-0.65Neutral0.001Benign0.010Benign4.32Benign0.04Affected0.16030.57890-10.93.99
c.3298G>A
G1100S
2D
AIThe SynGAP1 missense variant G1100S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign; no Foldetta stability result is available. Overall, the majority of evidence points to a benign impact for G1100S, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.972009Binding0.3600.8650.875-2.898Likely Benign0.100Likely BenignLikely Benign0.114Likely Benign-0.65Neutral0.943Possibly Damaging0.595Possibly Damaging2.10Pathogenic0.28Tolerated0.25010.569910-0.430.03
c.3377G>A
G1126D
2D
AISynGAP1 missense variant G1126D is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Functional prediction tools show a split opinion: benign predictions come from REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized, whereas pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. The AlphaMissense‑Default result is uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields benign. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign effect, which is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.894241Disordered0.837209Binding0.3450.9180.875Uncertain 1-8.888Likely Pathogenic0.432AmbiguousLikely Benign0.376Likely Benign-0.65Neutral0.906Possibly Damaging0.473Possibly Damaging4.82Benign0.02Affected3.7750.17250.22241-1-3.158.04
c.3586A>C
K1196Q
2D
AIThe SynGAP1 missense variant K1196Q is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Based on the preponderance of benign predictions and the lack of pathogenic evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.599170Disordered0.435699Uncertain0.8510.5950.250-5.222Likely Benign0.346AmbiguousLikely Benign0.342Likely Benign-0.65Neutral0.989Probably Damaging0.819Possibly Damaging5.38Benign0.07Tolerated0.38140.0945110.4-0.04
c.3934G>A
A1312T
2D
AISynGAP1 missense variant A1312T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.767246Disordered0.971112Binding0.3920.9020.750-4.137Likely Benign0.083Likely BenignLikely Benign0.155Likely Benign-0.65Neutral0.991Probably Damaging0.989Probably Damaging3.17Benign0.00Affected0.18650.760010-2.530.03
c.3944G>T
W1315L
2D
AIThe SynGAP1 missense variant W1315L is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.885302Disordered0.973142Binding0.4030.8890.7500.369Likely Benign0.304Likely BenignLikely Benign0.066Likely Benign-0.65Neutral0.115Benign0.057Benign4.29Benign0.16Tolerated0.22560.3338-2-24.7-73.05
c.49T>C
S17P
2D
AIThe SynGAP1 missense variant S17P is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus, SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a benign effect. AlphaMissense‑Optimized independently scores the variant as benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation; there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.483068Structured0.452228Uncertain0.3410.9100.375-3.251Likely Benign0.256Likely BenignLikely Benign0.210Likely Benign-0.65Neutral0.212Benign0.010Benign4.01Benign0.00Affected0.24060.64731-1-0.810.04
c.1117G>A
G373R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G373R is not reported in ClinVar (ClinVar ID None) but is present in gnomAD (ID 6‑33438022‑G‑A). Prediction tools that classify the variant as benign include PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Optimized, and premPS. Those that predict pathogenicity are REVEL, FoldX, Foldetta, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta as pathogenic. No prediction or folding result is missing or inconclusive. Overall, the majority of tools (six versus five) and the consensus of high‑accuracy methods lean toward a benign effect. This conclusion does not contradict ClinVar status, as the variant has no ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.529623Disordered0.429267Uncertain0.2950.7990.6256-33438022-G-A16.28e-7-7.878In-Between0.653Likely PathogenicLikely Benign4.28Destabilizing3.50.14Likely Benign2.21Destabilizing0.21Likely Benign0.510Likely Pathogenic-0.64Neutral0.001Benign0.000Benign3.90Benign0.01Affected3.53160.10890.4524-2-3-4.199.14
c.1117G>C
G373R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G373R is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include Rosetta, premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are REVEL, FoldX, Foldetta, SIFT, and AlphaMissense‑Default; ESM1b remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta as pathogenic. Overall, the majority of tools (seven benign vs five pathogenic) lean toward a benign interpretation, and this does not contradict the ClinVar status, which has no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.529623Disordered0.429267Uncertain0.2950.7990.625-7.878In-Between0.653Likely PathogenicLikely Benign4.28Destabilizing3.50.14Likely Benign2.21Destabilizing0.21Likely Benign0.522Likely Pathogenic-0.64Neutral0.001Benign0.000Benign3.90Benign0.01Affected3.53160.10890.4524-2-3-4.199.14
c.1130T>G
M377R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M377R is present in gnomAD (6‑33438035‑T‑G) and has no ClinVar entry. Prediction tools that report a benign effect include REVEL, FoldX, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are Rosetta and Foldetta. The high‑accuracy consensus (SGM‑Consensus) is “Likely Benign,” derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—all of which are benign. AlphaMissense‑Optimized also predicts benign, whereas Foldetta predicts pathogenic. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict the ClinVar status (which is currently absent).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.675549Disordered0.431183Uncertain0.3240.8840.6256-33438035-T-G-3.150Likely Benign0.219Likely BenignLikely Benign0.49Likely Benign0.44.81Destabilizing2.65Destabilizing0.69Ambiguous0.471Likely Benign-0.64Neutral0.004Benign0.009Benign5.46Benign0.18Tolerated4.32120.23690.1918-10-6.424.99
c.1148G>C
G383A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G383A is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are FoldX, Rosetta, and Foldetta. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as likely benign, and Foldetta as pathogenic. Thus, the majority of evidence points to a benign impact, with only a minority of high‑accuracy tools suggesting pathogenicity. The variant is most likely benign based on the overall predictions, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.728858Disordered0.429104Uncertain0.2960.9490.750-6.205Likely Benign0.105Likely BenignLikely Benign3.17Destabilizing1.23.47Destabilizing3.32Destabilizing0.04Likely Benign0.178Likely Benign-0.64Neutral0.055Benign0.037Benign4.20Benign0.11Tolerated0.38800.4361102.214.03
c.1157G>T
G386V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G386V is reported in gnomAD (6-33438062‑G‑T) but has no ClinVar entry. Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized, while those that predict a pathogenic outcome are FoldX, Rosetta, polyPhen‑2 (HumDiv and HumVar), and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as pathogenic. Overall, the majority of tools, including the high‑accuracy methods, lean toward a benign classification, and this assessment does not contradict any ClinVar status because none is available.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.733139Disordered0.424156Uncertain0.3340.8980.7506-33438062-G-T-6.405Likely Benign0.187Likely BenignLikely Benign4.88Destabilizing3.05.09Destabilizing4.99Destabilizing-0.17Likely Benign0.458Likely Benign-0.64Neutral0.985Probably Damaging0.720Possibly Damaging3.91Benign0.01Affected4.3230.16850.4189-3-14.642.08
c.1909T>G
S637A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S637A is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include AlphaMissense‑Default, AlphaMissense‑Optimized, ESM1b, FATHMM, PROVEAN, SIFT, polyPhen‑2 (HumDiv and HumVar), REVEL, FoldX, and premPS. No tool predicts a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is “Likely Benign,” and Foldetta, which integrates FoldX‑MD and Rosetta stability predictions, is inconclusive (Uncertain). Taken together, the overwhelming majority of evidence indicates a benign effect. The variant’s status is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.076542Structured0.083482Uncertain0.9200.2530.000-4.186Likely Benign0.137Likely BenignLikely Benign0.31Likely Benign0.10.99Ambiguous0.65Ambiguous0.22Likely Benign0.078Likely Benign-0.64Neutral0.120Benign0.182Benign3.41Benign1.00Tolerated0.48530.2996112.6-16.00
c.2040G>C
E680D
2D
AIThe SynGAP1 missense variant E680D is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: SGM‑Consensus, REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify it as benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) is benign. No prediction or folding stability result is missing or inconclusive. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.209395Structured0.136843Uncertain0.6360.3200.000-5.019Likely Benign0.289Likely BenignLikely Benign0.21Likely Benign0.80.27Likely Benign0.24Likely Benign-0.10Likely Benign0.121Likely Benign-0.64Neutral0.906Possibly Damaging0.295Benign3.66Benign0.32Tolerated0.21990.5208320.0-14.03
c.2040G>T
E680D
2D
AIThe SynGAP1 missense variant E680D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign or likely benign. Only polyPhen‑2 HumDiv flags the variant as pathogenic, representing the sole discordant prediction. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign; and Foldetta (combining FoldX‑MD and Rosetta outputs) is benign. No prediction or folding‑stability result is missing or inconclusive. **Based on the aggregate predictions, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status.**

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.209395Structured0.136843Uncertain0.6360.3200.000-5.019Likely Benign0.289Likely BenignLikely Benign0.21Likely Benign0.80.27Likely Benign0.24Likely Benign-0.10Likely Benign0.121Likely Benign-0.64Neutral0.906Possibly Damaging0.295Benign3.66Benign0.32Tolerated0.21990.5208320.0-14.03
c.2300T>G
I767S
2D
AIThe SynGAP1 missense variant I767S is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign. Only polyPhen‑2 HumDiv flags it as pathogenic, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign outcome. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are not available. Taken together, the preponderance of evidence points to a benign classification for I767S, and this assessment does not conflict with the absence of a ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.321458Structured0.927771Binding0.3690.8720.125-3.030Likely Benign0.388AmbiguousLikely Benign0.126Likely Benign-0.64Neutral0.925Possibly Damaging0.329Benign4.13Benign0.25Tolerated0.32420.1782-1-2-5.3-26.08
c.2479A>C
I827L
2D
AIThe SynGAP1 missense variant I827L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). In contrast, the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is also likely benign. No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the majority of evidence indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.590140Disordered0.636272Binding0.3830.8840.625-2.535Likely Benign0.179Likely BenignLikely Benign0.120Likely Benign-0.64Neutral0.981Probably Damaging0.970Probably Damaging2.71Benign0.43Tolerated0.07110.290122-0.70.00
c.2699C>A
T900K
2D
AISynGAP1 missense variant T900K has no ClinVar entry and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign), whereas pathogenic predictions come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized reports Benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign effect for T900K, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.465347Uncertain0.2890.9240.375-4.566Likely Benign0.721Likely PathogenicLikely Benign0.080Likely Benign-0.64Neutral0.782Possibly Damaging0.447Possibly Damaging2.69Benign0.92Tolerated0.11890.30380-1-3.227.07
c.2716C>G
L906V
2D
AIThe SynGAP1 missense variant L906V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as tolerated or benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and FATHMM predict a damaging or pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a Likely Benign consensus. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not conflict with ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.604312Disordered0.644316Binding0.3150.9200.250-5.105Likely Benign0.206Likely BenignLikely Benign0.105Likely Benign-0.64Neutral0.981Probably Damaging0.832Possibly Damaging2.46Pathogenic0.21Tolerated0.16320.3744210.4-14.03
c.3081C>A
N1027K
2D
AIThe SynGAP1 missense variant N1027K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, and the SGM‑Consensus result is benign; Foldetta predictions are unavailable. Overall, the balance of evidence favors a benign interpretation, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.831250Disordered0.994357Binding0.3470.7450.500-3.177Likely Benign0.841Likely PathogenicAmbiguous0.063Likely Benign-0.64Neutral0.481Possibly Damaging0.220Benign2.81Benign0.65Tolerated0.18080.607910-0.414.07
c.3081C>G
N1027K
2D
AIThe SynGAP1 missense variant N1027K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign, and AlphaMissense‑Optimized is uncertain. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.831250Disordered0.994357Binding0.3470.7450.500-3.177Likely Benign0.841Likely PathogenicAmbiguous0.063Likely Benign-0.64Neutral0.481Possibly Damaging0.220Benign2.81Benign0.65Tolerated0.18080.607910-0.414.07
c.3155G>A
G1052E
2D
AIThe SynGAP1 missense variant G1052E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a neutral impact. In contrast, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b predict a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates a likely benign effect. Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign classification, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984420Disordered0.892068Binding0.3670.9380.875-9.869Likely Pathogenic0.287Likely BenignLikely Benign0.448Likely Benign-0.64Neutral0.901Possibly Damaging0.537Possibly Damaging3.90Benign0.12Tolerated0.14050.38730-2-3.172.06
c.3169A>T
S1057C
2D
AIThe SynGAP1 missense variant S1057C is reported in gnomAD (ID 6‑33443721‑A‑T) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Two tools, polyPhen‑2 HumDiv and polyPhen‑2 HumVar, predict a pathogenic impact, while ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar classification (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.8756-33443721-A-T-7.529In-Between0.100Likely BenignLikely Benign0.258Likely Benign-0.64Neutral0.977Probably Damaging0.683Possibly Damaging5.23Benign0.10Tolerated3.7750.18560.6106-103.316.06
c.3283C>T
P1095S
2D
AIThe SynGAP1 missense variant P1095S is reported in gnomAD (ID 6‑33443835‑C‑T) and has no ClinVar entry. All evaluated in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Based on the unanimous benign predictions and the absence of any pathogenic signal, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.979251Binding0.3870.8701.0006-33443835-C-T74.51e-6-3.819Likely Benign0.182Likely BenignLikely Benign0.128Likely Benign-0.64Neutral0.207Benign0.072Benign2.80Benign1.00Tolerated3.7750.31500.5963-110.8-10.04
c.3311C>A
P1104Q
2D
AIThe SynGAP1 missense variant P1104Q is reported in gnomAD (ID 6‑33443863‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign likelihood. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is assigned).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.936162Disordered0.954801Binding0.4400.8630.8756-33443863-C-A-3.161Likely Benign0.104Likely BenignLikely Benign0.114Likely Benign-0.64Neutral0.986Probably Damaging0.825Possibly Damaging2.68Benign0.06Tolerated3.7750.14980.5063-10-1.931.01
c.3311C>G
P1104R
2D
AIThe SynGAP1 missense variant P1104R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus likewise indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.936162Disordered0.954801Binding0.4400.8630.875-3.864Likely Benign0.328Likely BenignLikely Benign0.099Likely Benign-0.64Neutral0.986Probably Damaging0.761Possibly Damaging2.68Benign0.06Tolerated0.13870.37030-2-2.959.07
c.3533A>T
Y1178F
2D
AIThe SynGAP1 missense variant Y1178F is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. Foldetta results are unavailable. Based on the consensus of all available predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.541878Disordered0.568433Binding0.5540.6880.250-3.081Likely Benign0.131Likely BenignLikely Benign0.162Likely Benign-0.64Neutral0.012Benign0.017Benign5.44Benign0.24Tolerated0.18930.2758734.1-16.00
c.382C>G
P128A
2D
AIThe SynGAP1 missense variant P128A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic outcome, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence supports a benign classification for P128A, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.497853Structured0.713069Binding0.3760.8780.625-3.677Likely Benign0.185Likely BenignLikely Benign0.068Likely Benign-0.64Neutral0.580Possibly Damaging0.140Benign4.21Benign0.75Tolerated0.38900.33531-13.4-26.04
c.3898C>A
P1300T
2D
AIThe SynGAP1 missense variant P1300T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence supports a benign classification, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.885826Binding0.4000.8340.875-4.522Likely Benign0.093Likely BenignLikely Benign0.070Likely Benign-0.64Neutral0.649Possibly Damaging0.266Benign2.87Benign0.21Tolerated0.15460.47290-10.93.99
c.3929C>A
T1310K
2D
AIThe SynGAP1 missense variant T1310K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.959076Binding0.3980.9040.750-4.388Likely Benign0.318Likely BenignLikely Benign0.101Likely Benign-0.64Neutral0.111Benign0.116Benign2.80Benign0.04Affected0.09920.29780-1-3.227.07
c.611C>G
S204C
2D
3DClick to see structure in 3D Viewer
AISynGAP1 S204C is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Prediction tools that classify the variant as benign include REVEL, Foldetta, premPS, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict pathogenicity are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus, derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates benign; and Foldetta, which integrates FoldX‑MD and Rosetta outputs, predicts a benign effect. FoldX and Rosetta individually report uncertain stability changes. Overall, the majority of computational evidence supports a benign effect, which is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.268042Structured0.420667Uncertain0.8160.4050.125Uncertain 1-6.613Likely Benign0.127Likely BenignLikely Benign0.65Ambiguous0.4-1.13Ambiguous-0.24Likely Benign0.10Likely Benign0.148Likely Benign-0.64Neutral0.978Probably Damaging0.753Possibly Damaging4.13Benign0.05Affected3.44100.06650.52370-13.316.06223.6-13.80.60.30.00.2XUncertainThe hydroxyl-containing Ser204, located in the N-terminal loop before the first anti-parallel β sheet strand (res. Ile205-Pro208), is replaced by the thiol-containing cysteine. In the WT simulations, Ser204 simultaneously forms hydrogen bonds with the backbone carbonyl of Asp201 and the hydroxyl group of Thr224, helping to stabilize the two anti-parallel β strands (res. Ile205-Lys207 and Cys219-Thr223) at the end of the β sheet. Since the thiol group of cysteine forms weaker hydrogen bonds than the hydroxyl group of serine, Cys204 does not maintain the hydrogen bond network as stably as Ser204 in the variant simulations. However, because the model ends abruptly at the N-terminus, no definite conclusions can be drawn from the simulations.
c.1132G>A
G378S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G378S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are REVEL, FoldX, Rosetta, Foldetta, polyPhen‑2 (HumDiv and HumVar), and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as likely benign, and Foldetta as pathogenic, giving a mixed outcome. Because the predictions are evenly split and the high‑accuracy methods are contradictory, the variant’s functional impact is uncertain. Based on the available evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.767246Disordered0.432858Uncertain0.3410.9150.625-5.331Likely Benign0.115Likely BenignLikely Benign6.75Destabilizing2.27.81Destabilizing7.28Destabilizing0.12Likely Benign0.565Likely Pathogenic-0.63Neutral1.000Probably Damaging0.986Probably Damaging1.33Pathogenic0.08Tolerated0.30130.472410-0.430.03
c.1133G>A
G378D
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant G378D is not reported in ClinVar (ClinVar ID: None) but is present in gnomAD (ID 6‑33438038‑G‑A). Prediction tools that classify the variant as benign include premPS, PROVEAN, SIFT, and AlphaMissense‑Optimized. Tools that predict pathogenicity are REVEL, FoldX, Rosetta, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Default. High‑accuracy methods give the following results: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic; and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts pathogenic. ESM1b is uncertain, and no other high‑accuracy predictions are available. Overall, the majority of evidence supports a pathogenic effect, and this conclusion does not contradict any ClinVar annotation because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.767246Disordered0.432858Uncertain0.3410.9150.6256-33438038-G-A16.97e-7-7.767In-Between0.576Likely PathogenicLikely Benign11.41Destabilizing5.011.84Destabilizing11.63Destabilizing0.50Likely Benign0.619Likely Pathogenic-0.63Neutral1.000Probably Damaging0.992Probably Damaging1.32Pathogenic0.08Tolerated4.32120.21300.2035-11-3.158.04
c.1142G>C
G381A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G381A is reported in gnomAD (variant ID 6-33438047‑G‑C) but has no ClinVar entry. Functional prediction tools fall into two groups: benign predictions come from premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and polyPhen‑2 HumVar; pathogenic predictions come from REVEL, FoldX, Rosetta, polyPhen‑2 HumDiv, FATHMM, and the SGM‑Consensus score. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as likely benign, while Foldetta (combining FoldX‑MD and Rosetta stability outputs) indicates a pathogenic effect. No prediction or stability result is missing or inconclusive. Overall, the majority of tools suggest a benign effect, and the high‑accuracy consensus leans toward benign, though Foldetta’s pathogenic signal introduces uncertainty. The variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status because none is available.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.724957Disordered0.431692Uncertain0.3010.9510.7506-33438047-G-C16.23e-7-6.266Likely Benign0.103Likely BenignLikely Benign3.97Destabilizing0.72.05Destabilizing3.01Destabilizing0.06Likely Benign0.507Likely Pathogenic-0.63Neutral0.718Possibly Damaging0.332Benign1.33Pathogenic0.52Tolerated4.3290.38090.4770012.214.03
c.2033G>A
S678N
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S678N is not reported in ClinVar (ClinVar status: not listed) but is present in gnomAD (gnomAD ID 6‑33441292‑G‑A). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome. High‑accuracy assessments are consistent: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates Likely Benign; and Foldetta (combining FoldX‑MD and Rosetta outputs) also predicts benign. Overall, the variant is most likely benign, and this conclusion does not contradict ClinVar status, which has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.301917Structured0.123585Uncertain0.6600.3210.0006-33441292-G-A16.20e-7-3.355Likely Benign0.139Likely BenignLikely Benign-0.10Likely Benign0.1-0.47Likely Benign-0.29Likely Benign0.38Likely Benign0.067Likely Benign-0.63Neutral0.001Benign0.002Benign3.43Benign0.14Tolerated3.43190.14350.486311-2.727.03
c.2177G>A
R726K
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant R726K is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only two tools—polyPhen‑2 HumDiv and polyPhen‑2 HumVar—predict a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates “Likely Benign”; and Foldetta (combining FoldX‑MD and Rosetta outputs) also predicts benign. No prediction or folding‑stability result is missing or inconclusive. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.521092Disordered0.449098Uncertain0.8880.5130.625-5.344Likely Benign0.231Likely BenignLikely Benign0.28Likely Benign0.0-0.02Likely Benign0.13Likely Benign0.20Likely Benign0.154Likely Benign-0.63Neutral0.990Probably Damaging0.998Probably Damaging2.67Benign0.16Tolerated0.49200.4042320.6-28.01
c.2188A>C
I730L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I730L is reported as “Likely Benign” in ClinVar and is not present in gnomAD. All available in‑silico predictors classify the change as benign: REVEL, FoldX, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments concur: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) also reports a benign effect. Consequently, the variant is most likely benign based on current predictions, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.420109Uncertain0.5910.6190.750-1.681Likely Benign0.069Likely BenignLikely Benign-0.05Likely Benign0.0-0.31Likely Benign-0.18Likely Benign-0.17Likely Benign0.028Likely Benign-0.63Neutral0.000Benign0.005Benign3.53Benign0.47Tolerated0.07390.286922-0.70.00
c.2222C>T
P741L
2D
AIThe SynGAP1 missense variant P741L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.885302Disordered0.493550Uncertain0.3540.8590.875-4.850Likely Benign0.058Likely BenignLikely Benign0.109Likely Benign-0.63Neutral0.001Benign0.003Benign2.84Benign0.03Affected0.19780.5780-3-35.416.04
c.2282G>A
R761Q
2D
AIThe SynGAP1 missense variant R761Q is listed in ClinVar (ID 2882770.0) with an “Uncertain” status and is present in gnomAD (6‑33441747‑G‑A). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.538167Disordered0.900613Binding0.3530.8650.250Uncertain 16-33441747-G-A116.81e-6-4.187Likely Benign0.202Likely BenignLikely Benign0.191Likely Benign-0.63Neutral0.996Probably Damaging0.878Possibly Damaging2.75Benign0.40Tolerated3.9950.26400.2329111.0-28.06
c.2324G>A
R775Q
2D
AIThe SynGAP1 missense variant R775Q is listed in ClinVar with an “Uncertain” status and is present in gnomAD (variant ID 6‑33442482‑G‑A). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores benign, and the SGM‑Consensus (derived from the same set of high‑confidence predictors) is “Likely Benign.” No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.444081Structured0.895337Binding0.3200.8960.250Conflicting 36-33442482-G-A111.41e-5-4.476Likely Benign0.229Likely BenignLikely Benign0.085Likely Benign-0.63Neutral0.969Probably Damaging0.863Possibly Damaging4.17Benign0.16Tolerated3.6460.28440.2863111.0-28.0610.1016/j.ajhg.2020.11.011
c.2338T>A
S780T
2D
AIThe SynGAP1 missense variant S780T is reported in ClinVar as “Not submitted” and is not present in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, while Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta) has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.599170Disordered0.812415Binding0.2830.8830.500-4.911Likely Benign0.157Likely BenignLikely Benign0.048Likely Benign-0.63Neutral0.951Possibly Damaging0.614Possibly Damaging2.66Benign0.84Tolerated0.14450.6631110.114.03
c.2380C>G
P794A
2D
AIThe SynGAP1 missense variant P794A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). All evaluated in‑silico predictors classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta results are unavailable, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.979741Disordered0.408951Uncertain0.5500.8980.875-3.766Likely Benign0.056Likely BenignLikely Benign0.038Likely Benign-0.63Neutral0.124Benign0.089Benign4.27Benign0.09Tolerated0.36920.52091-13.4-26.04
c.2383C>A
P795T
2D
AIThe SynGAP1 missense variant P795T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity, and the only uncertain result comes from ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign; Foldetta results are not available. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.972450Disordered0.410339Uncertain0.4570.9030.875-7.030In-Between0.060Likely BenignLikely Benign0.068Likely Benign-0.63Neutral0.036Benign0.026Benign4.26Benign0.09Tolerated0.17130.63810-10.93.99
c.2563C>A
L855I
2D
AIThe SynGAP1 missense variant L855I is not reported in ClinVar and is absent from gnomAD. In silico prediction tools that assess functional impact all converge on a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. No tool in the dataset indicates pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.485558Uncertain0.2850.8230.625-4.721Likely Benign0.093Likely BenignLikely Benign0.071Likely Benign-0.63Neutral0.004Benign0.008Benign4.08Benign0.35Tolerated0.09810.3893220.70.00
c.2686G>A
G896S
2D
AIThe SynGAP1 missense variant G896S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence supports a benign impact, and there is no conflict with ClinVar status (which has no entry). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.412816Uncertain0.3140.9230.625-2.712Likely Benign0.119Likely BenignLikely Benign0.103Likely Benign-0.63Neutral0.896Possibly Damaging0.334Benign2.59Benign0.41Tolerated0.26840.491110-0.430.03
c.2747T>G
V916G
2D
AIThe SynGAP1 missense variant V916G is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.642678Disordered0.835395Binding0.3080.8790.250-1.950Likely Benign0.091Likely BenignLikely Benign0.093Likely Benign-0.63Neutral0.666Possibly Damaging0.917Probably Damaging2.69Benign0.05Affected0.24200.2681-1-3-4.6-42.08
c.2902G>C
G968R
2D
AIThe SynGAP1 missense variant G968R is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the evidence strongly supports a benign classification, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.961360Binding0.3270.8960.750-4.492Likely Benign0.332Likely BenignLikely Benign0.140Likely Benign-0.63Neutral0.005Benign0.012Benign4.19Benign0.08Tolerated0.09720.5017-3-2-4.199.14
c.2922C>A
D974E
2D
AIThe SynGAP1 missense variant D974E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. The variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.964377Binding0.3890.8970.625-3.617Likely Benign0.109Likely BenignLikely Benign0.078Likely Benign-0.63Neutral0.036Benign0.026Benign4.26Benign0.05Affected0.21190.7516320.014.03
c.2922C>G
D974E
2D
AIThe SynGAP1 missense variant D974E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. The variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.964377Binding0.3890.8970.625-3.617Likely Benign0.109Likely BenignLikely Benign0.078Likely Benign-0.63Neutral0.036Benign0.026Benign4.26Benign0.05Affected0.21190.7516320.014.03
c.2944T>C
Y982H
2D
AIThe SynGAP1 missense variant Y982H has no ClinVar record and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, and the SGM‑Consensus result is benign; Foldetta predictions are unavailable. Overall, the evidence is mixed, but the majority of consensus‑based and high‑accuracy tools lean toward a benign interpretation. Thus, the variant is most likely benign, and this assessment does not contradict any ClinVar status, as none is currently assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.966717Binding0.2720.8950.625-2.675Likely Benign0.893Likely PathogenicAmbiguous0.093Likely Benign-0.63Neutral0.990Probably Damaging0.900Possibly Damaging3.92Benign0.00Affected0.23520.054502-1.9-26.03
c.2989G>T
A997S
2D
AIThe SynGAP1 missense variant A997S is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic call comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.948624Binding0.2730.9010.500-3.362Likely Benign0.080Likely BenignLikely Benign0.097Likely Benign-0.63Neutral0.224Benign0.066Benign4.18Benign0.00Affected0.26610.569411-2.616.00
c.3140C>T
S1047L
2D
AIThe SynGAP1 missense variant S1047L is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443692‑C‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores benign, and the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates benign. Foldetta stability analysis is not available for this variant. Overall, the preponderance of computational evidence points to a benign effect, which does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.963420Disordered0.933764Binding0.4090.9090.750Uncertain 16-33443692-C-T16.20e-7-4.062Likely Benign0.132Likely BenignLikely Benign0.032Likely Benign-0.63Neutral0.144Benign0.058Benign2.60Benign0.02Affected3.7750.15750.5555-2-34.626.08
c.3214A>C
K1072Q
2D
AIThe SynGAP1 missense variant K1072Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation because no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.984675Binding0.3070.9070.750-1.631Likely Benign0.589Likely PathogenicLikely Benign0.081Likely Benign-0.63Neutral0.999Probably Damaging0.995Probably Damaging3.95Benign0.12Tolerated0.44650.1804110.4-0.04
c.3377G>C
G1126A
2D
AIThe SynGAP1 missense variant G1126A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.894241Disordered0.837209Binding0.3450.9180.875-6.402Likely Benign0.080Likely BenignLikely Benign0.228Likely Benign-0.63Neutral0.124Benign0.061Benign4.83Benign0.56Tolerated0.35050.5333102.214.03
c.3757G>C
A1253P
2D
AIThe SynGAP1 missense variant A1253P is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, and FATHMM. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. The SGM Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (two pathogenic, two benign votes). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. High‑accuracy AlphaMissense‑Optimized predicts pathogenic, while AlphaMissense‑Default also predicts pathogenic; however, the majority of tools (five benign vs. four pathogenic) lean toward a benign classification. Thus, based on the current predictions, the variant is most likely benign, and this assessment does not contradict the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.661982Disordered0.391377Uncertain0.8810.5500.750-11.381Likely Pathogenic0.969Likely PathogenicLikely Pathogenic0.062Likely Benign-0.63Neutral0.568Possibly Damaging0.352Benign2.74Benign0.26Tolerated0.15650.35141-1-3.426.04
c.94A>G
T32A
2D
AIThe SynGAP1 missense variant T32A is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the consensus of the majority of tools and the high‑accuracy predictions point to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.437154Uncertain0.3490.8790.375-3.330Likely Benign0.072Likely BenignLikely Benign0.047Likely Benign-0.63Neutral0.043Benign0.016Benign4.21Benign0.00Affected0.41740.4742102.5-30.03
c.133A>C
N45H
2D
AIThe SynGAP1 missense variant N45H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized returns Benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for the variant, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.401658Structured0.431853Uncertain0.4980.7410.375-2.620Likely Benign0.285Likely BenignLikely Benign0.089Likely Benign-0.62Neutral0.943Possibly Damaging0.924Probably Damaging4.05Benign0.00Affected0.20090.8046210.323.04
c.1963C>G
L655V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L655V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, premPS, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, SGM‑Consensus indicates likely benign, while Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, yields an uncertain result. No tools predict pathogenicity, and the uncertain stability assessment does not alter the overall benign inference. Therefore, based on the available predictions, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.015344Structured0.268808Uncertain0.9610.2740.000-6.743Likely Benign0.127Likely BenignLikely Benign0.78Ambiguous0.00.58Ambiguous0.68Ambiguous0.38Likely Benign0.058Likely Benign-0.62Neutral0.008Benign0.003Benign3.45Benign0.44Tolerated0.15510.3190210.4-14.03
c.2434C>T
P812S
2D
AIThe SynGAP1 missense variant P812S is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33442986‑C‑T). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default remains uncertain, and no Foldetta stability result is available. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta data are missing. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.414856Structured0.842442Binding0.3880.9010.125Uncertain 16-33442986-C-T16.20e-7-5.689Likely Benign0.456AmbiguousLikely Benign0.162Likely Benign-0.62Neutral0.999Probably Damaging0.966Probably Damaging2.89Benign0.95Tolerated4.3240.34170.56991-10.8-10.04
c.2576G>A
S859N
2D
AIThe SynGAP1 missense variant S859N is reported in ClinVar as “None” and is not present in gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which contains no pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.648219Disordered0.497075Uncertain0.2880.8190.375-8.184Likely Pathogenic0.225Likely BenignLikely Benign0.142Likely Benign-0.62Neutral0.991Probably Damaging0.988Probably Damaging3.99Benign0.29Tolerated0.12210.522611-2.727.03
c.2701G>T
A901S
2D
AIThe SynGAP1 missense variant A901S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools that assess pathogenicity uniformly predict a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate benign. No tool in the dataset predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Overall, the collective predictions strongly suggest that the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.595080Disordered0.489838Uncertain0.3060.9170.375-3.284Likely Benign0.097Likely BenignLikely Benign0.043Likely Benign-0.62Neutral0.009Benign0.015Benign2.73Benign0.35Tolerated0.26950.658211-2.616.00
c.2762T>A
L921Q
2D
AIThe SynGAP1 missense variant L921Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of predictions (six benign vs. four pathogenic) lean toward a benign interpretation. Thus, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.608892Disordered0.943282Binding0.3110.8450.375-2.389Likely Benign0.311Likely BenignLikely Benign0.132Likely Benign-0.62Neutral0.994Probably Damaging0.940Probably Damaging2.41Pathogenic0.00Affected0.10970.1119-2-2-7.314.97
c.2989G>A
A997T
2D
AIThe SynGAP1 missense variant A997T is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (derived from the four high‑accuracy predictors) is benign; Foldetta results are unavailable. Taken together, the majority of computational evidence indicates a benign effect, which is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.948624Binding0.2730.9010.500Uncertain 1-4.102Likely Benign0.071Likely BenignLikely Benign0.085Likely Benign-0.62Neutral0.224Benign0.120Benign4.17Benign0.00Affected4.3240.15820.718210-2.530.03
c.3143G>A
G1048E
2D
AIThe SynGAP1 missense variant G1048E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only REVEL predicts a pathogenic outcome, while ESM1b is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect. The variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.923876Binding0.3460.9160.750-7.028In-Between0.331Likely BenignLikely Benign0.529Likely Pathogenic-0.62Neutral0.018Benign0.030Benign2.54Benign0.10Tolerated0.14440.40630-2-3.172.06
c.3152G>T
G1051V
2D
AIThe SynGAP1 missense variant G1051V is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33443704‑G‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields a benign prediction (2 benign vs. 1 pathogenic, 1 uncertain). Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign effect for G1051V, and this conclusion does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.900141Binding0.3580.9360.8756-33443704-G-T16.20e-7-7.098In-Between0.102Likely BenignLikely Benign0.460Likely Benign-0.62Neutral0.245Benign0.096Benign-0.74Pathogenic0.17Tolerated3.7750.12740.3680-3-14.642.08
c.3271C>G
L1091V
2D
AIThe SynGAP1 missense variant L1091V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only polyPhen‑2 HumDiv indicates a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign and the SGM‑Consensus also reports Likely Benign; Foldetta results are not available. Overall, the consensus of the available predictions points to a benign effect, and this conclusion is consistent with the lack of ClinVar evidence, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.924947Disordered0.984454Binding0.3760.8891.000-4.587Likely Benign0.328Likely BenignLikely Benign0.048Likely Benign-0.62Neutral0.779Possibly Damaging0.211Benign2.57Benign0.08Tolerated0.15600.3561210.4-14.03
c.3866A>G
K1289R
2D
AIThe SynGAP1 missense variant K1289R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; no tool predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta results are unavailable. Overall, the computational evidence strongly suggests the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.828700Binding0.5480.7870.625-2.127Likely Benign0.076Likely BenignLikely Benign0.090Likely Benign-0.62Neutral0.001Benign0.003Benign2.66Benign0.11Tolerated0.40460.071532-0.628.01
c.3952C>A
L1318M
2D
AIThe SynGAP1 missense variant L1318M is listed in gnomAD (ID 6‑33451826‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. In contrast, polyPhen‑2 HumDiv and SIFT predict pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar classification (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.968271Binding0.3990.8650.7506-33451826-C-A-4.625Likely Benign0.117Likely BenignLikely Benign0.039Likely Benign-0.62Neutral0.939Possibly Damaging0.396Benign4.01Benign0.03Affected3.7750.10830.402724-1.918.03
c.70G>C
V24L
2D
AIThe SynGAP1 missense variant V24L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect for V24L, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.541878Disordered0.438970Uncertain0.3820.8900.500-2.590Likely Benign0.320Likely BenignLikely Benign0.053Likely Benign-0.62Neutral0.043Benign0.011Benign3.94Benign0.00Affected0.11020.522621-0.414.03
c.70G>T
V24L
2D
AIThe SynGAP1 missense variant V24L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect for V24L, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.541878Disordered0.438970Uncertain0.3820.8900.500-2.590Likely Benign0.320Likely BenignLikely Benign0.053Likely Benign-0.62Neutral0.043Benign0.011Benign3.94Benign0.00Affected0.11020.522621-0.414.03
c.1114G>A
G372R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G372R is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are REVEL, Rosetta, Foldetta, SIFT, FATHMM, and AlphaMissense‑Default. Two tools, FoldX and ESM1b, returned uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized predicting benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicting pathogenic, and Foldetta predicting pathogenic. Overall, the majority of predictions (seven pathogenic vs. five benign) and the consensus of high‑accuracy methods indicate a pathogenic effect. This conclusion is not contradicted by ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.433034Structured0.430335Uncertain0.3220.7740.375-7.344In-Between0.617Likely PathogenicLikely Benign1.49Ambiguous0.32.87Destabilizing2.18Destabilizing0.20Likely Benign0.572Likely Pathogenic-0.61Neutral0.001Benign0.001Benign-0.74Pathogenic0.02Affected0.13230.4313-3-2-4.199.14
c.1114G>C
G372R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G372R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are REVEL, Rosetta, Foldetta, SIFT, FATHMM, and AlphaMissense‑Default. Two tools (FoldX and ESM1b) give uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as pathogenic. Overall, the majority of predictions (seven pathogenic vs five benign) indicate that the variant is most likely pathogenic, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.433034Structured0.430335Uncertain0.3220.7740.375-7.344In-Between0.617Likely PathogenicLikely Benign1.49Ambiguous0.32.87Destabilizing2.18Destabilizing0.20Likely Benign0.572Likely Pathogenic-0.61Neutral0.001Benign0.001Benign-0.74Pathogenic0.02Affected0.13230.4313-3-2-4.199.14
c.1124G>C
G375A
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant G375A is not reported in ClinVar and is absent from gnomAD. Prediction tools that classify the variant as benign include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are FoldX, Rosetta, and FATHMM. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is labeled “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as likely benign, while Foldetta (combining FoldX‑MD and Rosetta outputs) predicts a pathogenic impact. Overall, the majority of evidence points to a benign effect; this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.604312Disordered0.428340Uncertain0.3010.8360.625-5.986Likely Benign0.096Likely BenignLikely Benign2.52Destabilizing1.03.16Destabilizing2.84Destabilizing-0.09Likely Benign0.419Likely Benign-0.61Neutral0.020Benign0.008Benign1.33Pathogenic0.27Tolerated0.39910.5242102.214.03
c.1744G>C
E582Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 E582Q missense variant has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which is a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments—AlphaMissense‑Optimized, SGM‑Consensus, and Foldetta—all predict a benign impact, with Foldetta combining FoldX‑MD and Rosetta stability outputs. In contrast, the two polyPhen‑2 scores and AlphaMissense‑Default suggest pathogenicity, but these are outnumbered by benign predictions. Overall, the consensus of the majority of tools, including the high‑accuracy methods, indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar status (none available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.102787Structured0.033838Uncertain0.8450.2350.000-3.700Likely Benign0.605Likely PathogenicLikely Benign0.17Likely Benign0.10.21Likely Benign0.19Likely Benign-0.24Likely Benign0.138Likely Benign-0.61Neutral0.992Probably Damaging0.993Probably Damaging3.22Benign0.57Tolerated0.09790.3402220.0-0.98
c.203T>G
L68R
2D
AIThe SynGAP1 missense variant L68R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), which collectively suggest a likely benign impact. In contrast, polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default predict a pathogenic effect. The high‑accuracy AlphaMissense‑Optimized result is uncertain, and Foldetta stability analysis is unavailable. Overall, the balance of evidence leans toward a benign interpretation, and this assessment does not contradict any ClinVar annotation because no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.470567Uncertain0.4050.7680.250-3.427Likely Benign0.865Likely PathogenicAmbiguous0.147Likely Benign-0.61Neutral0.943Possibly Damaging0.766Possibly Damaging4.13Benign0.00Affected0.11780.0519-3-2-8.343.03
c.208C>G
R70G
2D
AIThe SynGAP1 missense variant R70G is listed in gnomAD (ID 6‑33425816‑C‑G) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions come from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default is uncertain, and Foldetta (FoldX‑MD/Rosetta stability assessment) has no result for this variant. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also indicates a likely benign outcome; Foldetta data are unavailable. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.458981Uncertain0.3920.7930.3756-33425816-C-G16.20e-7-3.555Likely Benign0.430AmbiguousLikely Benign0.095Likely Benign-0.61Neutral0.962Probably Damaging0.726Possibly Damaging4.11Benign0.00Affected4.3210.30780.3194-2-34.1-99.14
c.2333A>G
N778S
2D
AIThe SynGAP1 missense variant N778S is reported in gnomAD (ID 6‑33442491‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and HumVar—predict pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.494003Structured0.853922Binding0.2880.8870.5006-33442491-A-G11.28e-6-2.711Likely Benign0.097Likely BenignLikely Benign0.137Likely Benign-0.61Neutral0.843Possibly Damaging0.893Possibly Damaging4.32Benign0.86Tolerated3.6460.42850.6890112.7-27.03
c.236A>C
N79T
2D
AIThe SynGAP1 missense variant N79T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.618285Disordered0.457064Uncertain0.2900.8760.375-3.752Likely Benign0.102Likely BenignLikely Benign0.022Likely Benign-0.61Neutral0.371Benign0.018Benign4.21Benign0.00Affected0.11330.4890002.8-13.00
c.2384C>A
P795H
2D
AIThe SynGAP1 missense variant P795H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT predict a pathogenic outcome. ESM1b is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.972450Disordered0.410339Uncertain0.4570.9030.875-7.717In-Between0.121Likely BenignLikely Benign0.069Likely Benign-0.61Neutral0.898Possibly Damaging0.477Possibly Damaging4.24Benign0.05Affected0.19470.51840-2-1.640.02
c.2402G>C
G801A
2D
AIThe SynGAP1 missense variant G801A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). All evaluated in‑silico predictors classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. No tool predicts pathogenicity. The high‑accuracy consensus methods likewise support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are not available, so they do not influence the assessment. **Overall, the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.**

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.874069Disordered0.636323Binding0.3200.8920.625-3.747Likely Benign0.091Likely BenignLikely Benign0.025Likely Benign-0.61Neutral0.025Benign0.034Benign2.83Benign0.50Tolerated0.34580.4681102.214.03
c.2481C>G
I827M
2D
AIThe SynGAP1 missense variant I827M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). In contrast, the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is also likely benign. No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the majority of evidence indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.590140Disordered0.636272Binding0.3830.8840.625-4.910Likely Benign0.282Likely BenignLikely Benign0.143Likely Benign-0.61Neutral0.999Probably Damaging0.998Probably Damaging2.65Benign0.13Tolerated0.06420.256021-2.618.03
c.2768T>G
I923S
2D
AIThe SynGAP1 missense variant I923S is not reported in ClinVar and has no entry in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for I923S. This conclusion is not contradicted by ClinVar status, which has no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.562014Disordered0.964857Binding0.2920.8520.250-0.002Likely Benign0.760Likely PathogenicLikely Benign0.094Likely Benign-0.61Neutral0.912Possibly Damaging0.529Possibly Damaging2.73Benign0.33Tolerated0.33000.1455-1-2-5.3-26.08
c.2831G>C
G944A
2D
AIThe SynGAP1 missense variant G944A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.852408Binding0.3600.9230.750-6.397Likely Benign0.089Likely BenignLikely Benign0.314Likely Benign-0.61Neutral0.059Benign0.042Benign3.81Benign0.00Affected0.33520.4957102.214.03
c.2849G>A
G950D
2D
AIThe SynGAP1 missense variant G950D is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM, while ESM1b remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign outcome. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.888649Binding0.3680.9230.750-7.515In-Between0.245Likely BenignLikely Benign0.402Likely Benign-0.61Neutral0.411Benign0.131Benign2.26Pathogenic0.02Affected0.18740.28261-1-3.158.04
c.2870A>C
H957P
2D
AIThe SynGAP1 H957P missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and FATHMM. The high‑accuracy consensus (SGM‑Consensus) is derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yielding a Likely Benign classification (3 benign vs. 1 pathogenic). AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.968874Binding0.3620.9150.750-6.347Likely Benign0.061Likely BenignLikely Benign0.244Likely Benign-0.61Neutral0.453Possibly Damaging0.105Benign2.42Pathogenic0.13Tolerated0.23000.47010-21.6-40.02
c.2876A>C
H959P
2D
AIThe SynGAP1 missense variant H959P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.980566Binding0.3330.9050.750-8.902Likely Pathogenic0.070Likely BenignLikely Benign0.232Likely Benign-0.61Neutral0.453Possibly Damaging0.105Benign4.14Benign0.38Tolerated0.22840.49010-21.6-40.02
c.2884C>A
H962N
2D
AIThe SynGAP1 missense variant H962N is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.984483Binding0.3690.8860.750-8.481Likely Pathogenic0.098Likely BenignLikely Benign0.058Likely Benign-0.61Neutral0.174Benign0.045Benign4.18Benign0.24Tolerated0.19570.321621-0.3-23.04
c.3157A>T
S1053C
2D
AIThe SynGAP1 missense variant S1053C is catalogued in gnomAD (ID 6‑33443709‑A‑T) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The ESM1b score is uncertain, providing no clear direction. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no reported result for this variant. Overall, the majority of reliable predictors classify S1053C as benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.8756-33443709-A-T-7.574In-Between0.095Likely BenignLikely Benign0.220Likely Benign-0.61Neutral0.977Probably Damaging0.777Possibly Damaging5.30Benign0.11Tolerated3.7750.16750.5895-103.316.06
c.3352A>G
S1118G
2D
AIThe SynGAP1 missense variant S1118G is reported in gnomAD (ID 6‑33443904‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta) has no available result for this variant. Overall, the preponderance of evidence indicates that S1118G is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.828802Binding0.3100.9190.7506-33443904-A-G16.98e-7-1.615Likely Benign0.057Likely BenignLikely Benign0.146Likely Benign-0.61Neutral0.790Possibly Damaging0.433Benign5.82Benign0.08Tolerated4.3220.27370.4657010.4-30.03
c.338G>C
G113A
2D
AIThe SynGAP1 missense variant G113A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign. Foldetta results are not available for this variant. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.639486Binding0.3500.8700.750-3.552Likely Benign0.162Likely BenignLikely Benign0.045Likely Benign-0.61Neutral0.131Benign0.039Benign4.20Benign0.22Tolerated0.40590.4684102.214.03
c.3519C>G
I1173M
2D
AIThe SynGAP1 missense variant I1173M is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable, so they do not influence the overall assessment. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.501700Disordered0.653145Binding0.5210.7560.375-3.301Likely Benign0.196Likely BenignLikely Benign0.327Likely Benign-0.61Neutral0.973Probably Damaging0.830Possibly Damaging5.37Benign0.15Tolerated0.06760.229521-2.618.03
c.517C>A
L173M
2D
AIThe SynGAP1 missense variant L173M is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Two tools—AlphaMissense‑Default and ESM1b—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because it yields two benign and two uncertain calls, and Foldetta data are unavailable. Overall, the balance of evidence favors a benign classification, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.534167Disordered0.491566Uncertain0.3900.6310.375-7.149In-Between0.534AmbiguousLikely Benign0.129Likely Benign-0.61Neutral0.940Possibly Damaging0.564Possibly Damaging3.96Benign0.20Tolerated0.06480.312342-1.918.03
c.752A>G
K251R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant K251R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include FoldX, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are REVEL, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. Rosetta and Foldetta give uncertain results. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, SGM‑Consensus as Likely Benign, and Foldetta as Uncertain. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.447574Structured0.226632Uncertain0.7580.3120.125-4.355Likely Benign0.123Likely BenignLikely Benign-0.37Likely Benign0.0-0.64Ambiguous-0.51Ambiguous0.14Likely Benign0.531Likely Pathogenic-0.61Neutral0.970Probably Damaging0.681Possibly Damaging5.92Benign0.34Tolerated0.47560.104932-0.628.01
c.101A>C
Y34S
2D
AIThe SynGAP1 missense variant Y34S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for Y34S, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.529623Disordered0.435847Uncertain0.3030.8550.375-0.994Likely Benign0.237Likely BenignLikely Benign0.178Likely Benign-0.60Neutral0.824Possibly Damaging0.775Possibly Damaging4.19Benign0.00Affected0.47600.2884-3-20.5-76.10
c.109T>A
S37T
2D
AIThe SynGAP1 missense variant S37T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumVar and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.642678Disordered0.433492Uncertain0.3170.8060.500-3.854Likely Benign0.134Likely BenignLikely Benign0.062Likely Benign-0.60Neutral0.140Benign0.481Possibly Damaging3.95Benign0.00Affected0.20930.5974110.114.03
c.1198G>C
V400L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V400L is listed in ClinVar as Benign (ClinVar ID 1166313.0) and is present in gnomAD (variant ID 6‑33438103‑G‑C). Prediction tools that agree on a benign effect include REVEL, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the only inconclusive result is from FoldX, which is treated as unavailable. High‑accuracy assessments confirm benignity: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is benign; and Foldetta, which integrates FoldX‑MD and Rosetta outputs, is benign. Overall, the computational evidence strongly supports a benign classification, consistent with the ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.398279Structured0.415488Uncertain0.9510.4510.000Benign 16-33438103-G-C221.36e-5-1.000Likely Benign0.137Likely BenignLikely Benign-0.71Ambiguous0.20.39Likely Benign-0.16Likely Benign-0.29Likely Benign0.325Likely Benign-0.60Neutral0.001Benign0.001Benign5.33Benign0.64Tolerated3.38270.10060.524221-0.414.03251.0-30.10.00.00.70.1XPotentially BenignThe iso-propyl side chain of Val400, located in an anti-parallel β sheet strand (res. Ala399-Ile411), hydrophobically packs against hydrophobic residues within the anti-parallel β sheet of the C2 domain (e.g., Ile268, Ala404, Leu325, Leu402). Val400 is swapped for another hydrophobic residue, leucine, whose branched hydrocarbon side chain is of a comparable size and thus packs favorably within the C2 domain. In short, the residue swap has no apparent negative effect on the structure based on the variant simulations.10.1016/j.ajhg.2020.11.011
c.1198G>T
V400L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V400L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Functional prediction tools that agree on a benign effect include REVEL, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, PROVEAN, premPS, AlphaMissense‑Default, AlphaMissense‑Optimized, and Rosetta. No tool predicts a pathogenic outcome; the only inconclusive result is from FoldX (Uncertain). High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts Benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields Likely Benign; and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts Benign. Based on the collective evidence, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.398279Structured0.415488Uncertain0.9510.4510.000-1.000Likely Benign0.137Likely BenignLikely Benign-0.71Ambiguous0.20.39Likely Benign-0.16Likely Benign-0.29Likely Benign0.325Likely Benign-0.60Neutral0.001Benign0.001Benign5.33Benign0.64Tolerated3.38270.10060.524221-0.414.03251.0-30.10.00.00.70.1XPotentially BenignThe iso-propyl side chain of Val400, located in an anti-parallel β sheet strand (res. Ala399-Ile411), hydrophobically packs against hydrophobic residues within the anti-parallel β sheet of the C2 domain (e.g., Ile268, Ala404, Leu325, Leu402). Val400 is swapped for another hydrophobic residue, leucine, whose branched hydrocarbon side chain is of a comparable size and thus packs favorably within the C2 domain. In short, the residue swap has no apparent negative effect on the structure based on the variant simulations.10.1016/j.ajhg.2020.11.011
c.136C>T
P46S
2D
AIThe SynGAP1 missense variant P46S is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. The Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence—including high‑accuracy tools—points to a benign effect, and this conclusion does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.390993Structured0.433588Uncertain0.5490.7410.375Uncertain 1-3.338Likely Benign0.302Likely BenignLikely Benign0.066Likely Benign-0.60Neutral0.909Possibly Damaging0.901Possibly Damaging4.15Benign0.00Affected0.39040.57711-10.8-10.04
c.2008C>G
L670V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense change L670V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score all indicate benign. Only ESM1b predicts pathogenicity, while FoldX, Rosetta, and Foldetta provide uncertain or inconclusive stability results. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign; the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is benign; and Foldetta remains uncertain. Taken together, the overwhelming majority of evidence supports a benign interpretation, and this conclusion does not conflict with the absence of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.161087Structured0.090855Uncertain0.8120.3850.000-9.829Likely Pathogenic0.113Likely BenignLikely Benign1.45Ambiguous0.11.05Ambiguous1.25Ambiguous0.15Likely Benign0.025Likely Benign-0.60Neutral0.127Benign0.023Benign3.67Benign0.74Tolerated0.15580.4108210.4-14.03
c.2301C>G
I767M
2D
AIThe SynGAP1 missense variant I767M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic effect. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence supports a benign classification for I767M, and this conclusion does not contradict any ClinVar annotation, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.321458Structured0.927771Binding0.3690.8720.125-2.384Likely Benign0.084Likely BenignLikely Benign0.089Likely Benign-0.60Neutral0.835Possibly Damaging0.486Possibly Damaging4.05Benign0.11Tolerated0.07880.337721-2.618.03
c.2549G>A
G850E
2D
AIThe SynGAP1 missense variant G850E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. In contrast, polyPhen‑2 HumDiv and SIFT predict a pathogenic outcome. When predictions are grouped by consensus, the benign group contains seven tools, whereas the pathogenic group contains two. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized reports a benign effect, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. Foldetta results are unavailable. Overall, the majority of evidence supports a benign classification, and this is consistent with the lack of ClinVar annotation. The variant is most likely benign based on predictions, and there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.648219Disordered0.540897Binding0.3120.8200.500-4.052Likely Benign0.247Likely BenignLikely Benign0.217Likely Benign-0.60Neutral0.770Possibly Damaging0.327Benign4.28Benign0.02Affected0.16120.42320-2-3.172.06
c.2549G>C
G850A
2D
AIThe SynGAP1 missense variant G850A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also predicts Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.648219Disordered0.540897Binding0.3120.8200.500-4.731Likely Benign0.087Likely BenignLikely Benign0.164Likely Benign-0.60Neutral0.580Possibly Damaging0.303Benign4.27Benign0.09Tolerated0.39910.4837102.214.03
c.2752G>C
A918P
2D
AIThe SynGAP1 missense variant A918P is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.632174Disordered0.891459Binding0.3170.8600.250-2.087Likely Benign0.087Likely BenignLikely Benign0.136Likely Benign-0.60Neutral0.998Probably Damaging0.924Probably Damaging2.59Benign0.04Affected0.20520.49851-1-3.426.04
c.2803G>T
A935S
2D
AIThe SynGAP1 missense variant A935S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the overall assessment. Overall, the majority of evidence points to a benign effect for A935S, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.736850Disordered0.980490Binding0.2860.8650.625-3.361Likely Benign0.139Likely BenignLikely Benign0.167Likely Benign-0.60Neutral0.999Probably Damaging0.996Probably Damaging2.53Benign0.00Affected0.27190.549611-2.616.00
c.2839G>A
G947R
2D
AIThe SynGAP1 missense variant G947R is listed in gnomAD (6-33443391-G-A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Optimized) and pathogenic (SIFT). Two tools remain uncertain (ESM1b, AlphaMissense‑Default). High‑accuracy assessments show AlphaMissense‑Optimized predicts a benign effect, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—does not reach a definitive conclusion (two benign, two uncertain). Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no reported result for this variant. Overall, the preponderance of evidence points to a benign impact, and this assessment does not contradict any ClinVar status, as none is available.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988695Disordered0.850554Binding0.3580.9190.7506-33443391-G-A63.72e-6-7.481In-Between0.343AmbiguousLikely Benign0.273Likely Benign-0.60Neutral0.411Benign0.140Benign4.94Benign0.04Affected4.3240.10340.4733-2-3-4.199.14
c.2839G>C
G947R
2D
AIThe SynGAP1 missense variant G947R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while ESM1b and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive, and Foldetta stability analysis is unavailable. Overall, the balance of evidence favors a benign classification, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988695Disordered0.850554Binding0.3580.9190.750-7.481In-Between0.343AmbiguousLikely Benign0.273Likely Benign-0.60Neutral0.411Benign0.140Benign4.94Benign0.04Affected4.3240.10340.4733-2-3-4.199.14
c.2842G>C
G948R
2D
AIThe SynGAP1 missense variant G948R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and SIFT—suggest a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.862121Binding0.3650.9190.750-6.782Likely Benign0.315Likely BenignLikely Benign0.266Likely Benign-0.60Neutral0.818Possibly Damaging0.435Benign4.58Benign0.04Affected0.10690.4933-3-2-4.199.14
c.3040G>A
G1014S
2D
AIThe SynGAP1 missense variant G1014S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.771762Disordered0.914808Binding0.2930.8350.625-3.219Likely Benign0.085Likely BenignLikely Benign0.026Likely Benign-0.60Neutral0.068Benign0.039Benign2.95Benign0.50Tolerated0.26770.540810-0.430.03
c.3073C>G
Q1025E
2D
AIThe SynGAP1 missense variant Q1025E is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only polyPhen‑2 HumDiv predicts it as pathogenic. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.993410Binding0.3630.7460.500-3.010Likely Benign0.254Likely BenignLikely Benign0.077Likely Benign-0.60Neutral0.649Possibly Damaging0.353Benign2.79Benign1.00Tolerated0.13910.2269220.00.98
c.3178G>T
G1060C
2D
AIThe SynGAP1 missense variant G1060C is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for G1060C, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979242Disordered0.913048Binding0.4070.9280.875-9.630Likely Pathogenic0.116Likely BenignLikely Benign0.363Likely Benign-0.60Neutral0.999Probably Damaging0.917Probably Damaging2.63Benign0.12Tolerated0.13400.4227-3-32.946.09
c.3229A>G
T1077A
2D
AIThe SynGAP1 missense variant T1077A is catalogued in gnomAD (ID 6‑33443781‑A‑G) but has no ClinVar entry. Across a broad panel of in silico predictors, every tool reports a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool in the set predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized returns a benign prediction, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence overwhelmingly supports a benign effect, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.903857Disordered0.988141Binding0.3290.8920.7506-33443781-A-G-3.303Likely Benign0.280Likely BenignLikely Benign0.153Likely Benign-0.60Neutral0.288Benign0.194Benign4.25Benign0.10Tolerated3.7750.33730.4393012.5-30.03
c.3344T>A
I1115N
2D
AIThe SynGAP1 missense variant I1115N is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on current predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.892339Binding0.3080.9120.750-4.018Likely Benign0.118Likely BenignLikely Benign0.095Likely Benign-0.60Neutral0.009Benign0.011Benign2.77Benign0.08Tolerated0.12990.1270-2-3-8.00.94
c.3346G>A
G1116R
2D
AIThe SynGAP1 missense variant G1116R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the majority of computational evidence points to a benign effect for G1116R, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.873279Binding0.3200.9090.750-6.379Likely Benign0.495AmbiguousLikely Benign0.368Likely Benign-0.60Neutral0.922Possibly Damaging0.657Possibly Damaging4.18Benign0.04Affected0.09250.4342-3-2-4.199.14
c.3346G>C
G1116R
2D
AIThe SynGAP1 missense variant G1116R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the majority of computational evidence points to a benign effect for G1116R, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.873279Binding0.3200.9090.750-6.379Likely Benign0.495AmbiguousLikely Benign0.368Likely Benign-0.60Neutral0.922Possibly Damaging0.657Possibly Damaging4.18Benign0.04Affected0.09250.4342-3-2-4.199.14
c.3374G>C
G1125A
2D
AIThe SynGAP1 missense variant G1125A is listed in ClinVar with an “Uncertain” status and is present in gnomAD (6‑33443926‑G‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic effect. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM‑Consensus (derived from the four high‑accuracy tools) is benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.835839Binding0.3390.9230.875Uncertain 16-33443926-G-C16.68e-7-6.569Likely Benign0.083Likely BenignLikely Benign0.232Likely Benign-0.60Neutral0.999Probably Damaging0.995Probably Damaging4.60Benign0.11Tolerated3.7750.33950.5138102.214.03
c.3394T>G
S1132A
2D
AIThe SynGAP1 missense variant S1132A is not reported in ClinVar and is absent from gnomAD, indicating no documented population frequency. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign status. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.845506Binding0.2890.8940.750-3.401Likely Benign0.078Likely BenignLikely Benign0.213Likely Benign-0.60Neutral0.061Benign0.013Benign5.47Benign0.55Tolerated0.44160.5683112.6-16.00
c.3398T>G
I1133S
2D
AIThe SynGAP1 missense variant I1133S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is likely benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the collective evidence strongly supports a benign impact for I1133S, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.832785Binding0.3160.8920.750-4.034Likely Benign0.492AmbiguousLikely Benign0.186Likely Benign-0.60Neutral0.007Benign0.016Benign5.70Benign0.08Tolerated0.27620.1110-1-2-5.3-26.08
c.3452C>T
S1151F
2D
AIThe SynGAP1 missense variant S1151F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. There is no ClinVar entry to contradict this assessment, so the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.741537Disordered0.805072Binding0.3940.8390.625-4.433Likely Benign0.661Likely PathogenicLikely Benign0.170Likely Benign-0.60Neutral0.995Probably Damaging0.925Probably Damaging2.70Benign0.19Tolerated0.07490.5370-3-23.660.10
c.3502A>C
I1168L
2D
AIThe SynGAP1 missense variant I1168L is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in‑silico predictors indicates a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all score the substitution as tolerated, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also classifies it as likely benign. Only AlphaMissense‑Default predicts a pathogenic outcome, but this is an outlier relative to the other tools. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized reports a benign effect, and the SGM‑Consensus (majority vote) concurs. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so it does not influence the overall assessment. Overall, the computational evidence overwhelmingly favors a benign classification, and this is consistent with the absence of a ClinVar pathogenic report.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.642678Disordered0.763262Binding0.4230.7960.500-1.855Likely Benign0.604Likely PathogenicLikely Benign0.361Likely Benign-0.60Neutral0.241Benign0.286Benign5.48Benign0.20Tolerated0.09560.446522-0.70.00
c.3512C>G
A1171G
2D
AIThe SynGAP1 missense variant A1171G (Ala→Gly at residue 1171) is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate a benign effect, and no tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome, while Foldetta results are unavailable. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.599170Disordered0.702689Binding0.4720.7750.500-3.487Likely Benign0.286Likely BenignLikely Benign0.141Likely Benign-0.60Neutral0.245Benign0.138Benign5.38Benign0.08Tolerated0.19570.320110-2.2-14.03
c.3589G>C
E1197Q
2D
AIThe SynGAP1 missense variant E1197Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which is a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as benign, and no Foldetta stability data are available. Overall, the balance of evidence favors a benign interpretation, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.613573Disordered0.437361Uncertain0.8270.5990.250-2.771Likely Benign0.692Likely PathogenicLikely Benign0.304Likely Benign-0.60Neutral0.999Probably Damaging0.996Probably Damaging5.44Benign0.29Tolerated0.06900.5265220.0-0.98
c.3748C>A
Q1250K
2D
AIThe SynGAP1 missense variant Q1250K is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. Only two tools, polyPhen‑2 HumDiv and HumVar, predict a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.759478Disordered0.360484Uncertain0.8810.5540.750-6.804Likely Benign0.258Likely BenignLikely Benign0.083Likely Benign-0.60Neutral0.985Probably Damaging0.981Probably Damaging2.81Benign0.13Tolerated0.14640.248411-0.40.04
c.3832C>A
P1278T
2D
AIThe SynGAP1 missense variant P1278T is catalogued in gnomAD (ID 6‑33447880‑C‑A) but has no ClinVar entry. Across a broad panel of in silico predictors, every tool reports a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool in the set predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized returns a benign prediction, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status remains unavailable. Overall, the computational evidence overwhelmingly supports a benign effect, and this assessment does not contradict any ClinVar classification. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.806955Binding0.5320.7220.7506-33447880-C-A-5.505Likely Benign0.095Likely BenignLikely Benign0.064Likely Benign-0.60Neutral0.059Benign0.026Benign2.73Benign0.11Tolerated3.7750.18250.4053-100.93.99
c.529T>A
F177I
2D
AIThe SynGAP1 missense variant F177I is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. Tools that predict a pathogenic effect are ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 vs 2), and Foldetta results are unavailable. Overall, the majority of predictions (six benign vs. three pathogenic) suggest a benign impact, though the presence of pathogenic signals from high‑accuracy tools introduces uncertainty. The variant is most likely benign based on the current evidence, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.505461Disordered0.461817Uncertain0.3570.5980.500-10.208Likely Pathogenic0.980Likely PathogenicLikely Pathogenic0.148Likely Benign-0.60Neutral0.131Benign0.058Benign4.18Benign0.11Tolerated0.22820.3299101.7-34.02
c.913A>T
T305S
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant T305S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, FoldX, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. Predictions that are inconclusive or uncertain are provided by Rosetta, Foldetta, and premPS. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates “Likely Benign,” and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, yields an uncertain result. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.359901Structured0.299706Uncertain0.8720.2740.125-2.899Likely Benign0.107Likely BenignLikely Benign0.45Likely Benign0.41.21Ambiguous0.83Ambiguous0.55Ambiguous0.135Likely Benign-0.60Neutral0.760Possibly Damaging0.484Possibly Damaging1.86Pathogenic0.54Tolerated0.35790.449611-0.1-14.03
c.914C>G
T305S
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant T305S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, FoldX, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. Predictions that are inconclusive or uncertain are provided by Rosetta, Foldetta, and premPS. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates “Likely Benign,” and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, yields an uncertain result. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.359901Structured0.299706Uncertain0.8720.2740.125-2.899Likely Benign0.107Likely BenignLikely Benign0.45Likely Benign0.41.21Ambiguous0.83Ambiguous0.55Ambiguous0.104Likely Benign-0.60Neutral0.760Possibly Damaging0.484Possibly Damaging1.86Pathogenic0.54Tolerated0.35790.449611-0.1-14.03
c.1145G>C
G382A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G382A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are FoldX, Rosetta, polyPhen‑2 (HumDiv and HumVar), and FATHMM. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, SGM‑Consensus as Likely Benign, while Foldetta (combining FoldX‑MD and Rosetta outputs) predicts a pathogenic impact. Overall, the majority of predictions lean toward a benign effect, and this consensus does not contradict any ClinVar status (none available). Thus, based on the available computational evidence, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.728858Disordered0.429690Uncertain0.3150.9510.750-6.323Likely Benign0.109Likely BenignLikely Benign2.90Destabilizing0.63.00Destabilizing2.95Destabilizing-0.03Likely Benign0.495Likely Benign-0.59Neutral0.953Possibly Damaging0.952Probably Damaging1.33Pathogenic0.12Tolerated0.40480.4576102.214.03
c.2723A>C
Q908P
2D
AIThe SynGAP1 missense variant Q908P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools, polyPhen‑2 HumDiv and HumVar, predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect for Q908P, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.608892Disordered0.678728Binding0.2750.9170.250-4.446Likely Benign0.151Likely BenignLikely Benign0.196Likely Benign-0.59Neutral0.996Probably Damaging0.992Probably Damaging2.51Benign0.11Tolerated0.23790.51210-11.9-31.01
c.2834A>G
H945R
2D
AIThe SynGAP1 missense variant H945R is reported in gnomAD (variant ID 6‑33443386‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.7506-33443386-A-G16.20e-7-5.186Likely Benign0.118Likely BenignLikely Benign0.333Likely Benign-0.59Neutral0.982Probably Damaging0.903Possibly Damaging5.05Benign0.08Tolerated4.3240.27640.302002-1.319.05
c.3143G>T
G1048V
2D
AIThe SynGAP1 missense variant G1048V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are REVEL, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. Thus, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.923876Binding0.3460.9160.750-6.108Likely Benign0.079Likely BenignLikely Benign0.520Likely Pathogenic-0.59Neutral0.958Probably Damaging0.787Possibly Damaging2.54Benign0.11Tolerated0.13120.3688-1-34.642.08
c.3160G>T
G1054C
2D
AIThe SynGAP1 missense variant G1054C is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.878015Binding0.3890.9360.875-9.548Likely Pathogenic0.118Likely BenignLikely Benign0.297Likely Benign-0.59Neutral0.999Probably Damaging0.907Possibly Damaging4.00Benign0.10Tolerated0.14130.4427-3-32.946.09
c.3277C>G
Q1093E
2D
AIThe SynGAP1 missense change Q1093E is not reported in ClinVar and is absent from gnomAD. In silico assessment shows unanimous benign predictions: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign. No tool predicts pathogenicity. High‑accuracy consensus methods reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” The protein‑folding stability predictor Foldetta was not available for this variant. Overall, the evidence strongly supports a benign effect, and this conclusion is consistent with the lack of ClinVar annotation. Thus, the variant is most likely benign and does not contradict existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983312Binding0.3510.8861.000-3.104Likely Benign0.265Likely BenignLikely Benign0.047Likely Benign-0.59Neutral0.112Benign0.041Benign2.78Benign0.07Tolerated0.15140.3717220.00.98
c.3385C>A
L1129M
2D
AIThe SynGAP1 missense variant L1129M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect for L1129M, and this conclusion does not conflict with ClinVar, which contains no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.903857Disordered0.876543Binding0.3390.9090.875-4.233Likely Benign0.086Likely BenignLikely Benign0.295Likely Benign-0.59Neutral0.918Possibly Damaging0.697Possibly Damaging5.43Benign0.00Affected0.11000.423642-1.918.03
c.3475T>A
S1159T
2D
AIThe SynGAP1 missense variant S1159T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. The variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.626927Disordered0.867068Binding0.3430.8460.375-4.057Likely Benign0.207Likely BenignLikely Benign0.076Likely Benign-0.59Neutral0.979Probably Damaging0.982Probably Damaging2.68Benign0.28Tolerated0.11140.5715110.114.03
c.3496G>T
A1166S
2D
AIThe SynGAP1 missense variant A1166S is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy methods that are available—AlphaMissense‑Optimized and the SGM‑Consensus—both support a benign classification. Consequently, the variant is most likely benign according to the majority of predictive evidence, and this assessment does not contradict any ClinVar annotation because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.575842Disordered0.811691Binding0.3810.8030.375-2.587Likely Benign0.396AmbiguousLikely Benign0.308Likely Benign-0.59Neutral0.995Probably Damaging0.949Probably Damaging5.41Benign0.35Tolerated0.25680.523911-2.616.00
c.3691A>C
S1231R
2D
AIThe SynGAP1 missense variant S1231R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as “Uncertain,” SGM‑Consensus as “Likely Benign,” and Foldetta (combining FoldX‑MD and Rosetta outputs) is unavailable. Overall, the balance of evidence favors a benign interpretation; this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.490133Structured0.519419Binding0.8760.5440.250-6.862Likely Benign0.847Likely PathogenicAmbiguous0.108Likely Benign-0.59Neutral0.801Possibly Damaging0.417Benign2.68Benign0.11Tolerated0.07090.29600-1-3.769.11
c.3693C>A
S1231R
2D
AIThe SynGAP1 missense variant S1231R is not reported in ClinVar (ClinVar status: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain, providing no clear direction. High‑accuracy assessments show the SGM‑Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as Likely Benign, while AlphaMissense‑Optimized remains uncertain; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.490133Structured0.519419Binding0.8760.5440.250-6.862Likely Benign0.847Likely PathogenicAmbiguous0.132Likely Benign-0.59Neutral0.801Possibly Damaging0.417Benign2.68Benign0.11Tolerated0.07090.29600-1-3.769.11
c.3693C>G
S1231R
2D
AIThe SynGAP1 missense variant S1231R is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign. Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict ClinVar status, which has no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.490133Structured0.519419Binding0.8760.5440.250-6.862Likely Benign0.847Likely PathogenicAmbiguous0.132Likely Benign-0.59Neutral0.801Possibly Damaging0.417Benign2.68Benign0.11Tolerated0.07090.29600-1-3.769.11
c.3697A>G
I1233V
2D
AIThe SynGAP1 missense change I1233V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only AlphaMissense‑Default predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign effect for I1233V, and this conclusion is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.525368Disordered0.564054Binding0.8810.5310.125-2.826Likely Benign0.615Likely PathogenicLikely Benign0.036Likely Benign-0.59Neutral0.437Benign0.170Benign2.79Benign0.06Tolerated0.09500.327043-0.3-14.03
c.3929C>G
T1310R
2D
AIThe SynGAP1 missense variant T1310R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as tolerated or benign. Only SIFT predicts a damaging outcome, labeling it pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign status. High‑accuracy assessments further support this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus itself is benign; Foldetta results are unavailable. Consequently, the aggregate evidence indicates that T1310R is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.959076Binding0.3980.9040.750-3.632Likely Benign0.226Likely BenignLikely Benign0.231Likely Benign-0.59Neutral0.001Benign0.006Benign2.78Benign0.03Affected0.08440.2501-1-1-3.855.08
c.5G>T
S2I
2D
AIThe SynGAP1 missense variant S2I is catalogued in gnomAD (6‑33420269‑G‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all report benign or likely benign. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments confirm the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus, derived from the majority of the high‑confidence predictors, is benign. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that S2I is most likely benign, and this assessment does not contradict any ClinVar status, as none is reported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.543646Binding0.3820.9220.7506-33420269-G-T-4.947Likely Benign0.439AmbiguousLikely Benign0.031Likely Benign-0.59Neutral0.212Benign0.020Benign4.04Benign0.00Affected4.3210.10210.5980-2-15.326.08
c.103G>C
V35L
2D
AIThe SynGAP1 missense variant V35L is reported in gnomAD (variant ID 6-33423512‑G‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence, including the high‑accuracy tools, points to a benign effect. This conclusion is not contradicted by ClinVar, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.613573Disordered0.434838Uncertain0.3600.8510.3756-33423512-G-C42.48e-6-2.893Likely Benign0.108Likely BenignLikely Benign0.039Likely Benign-0.58Neutral0.481Possibly Damaging0.506Possibly Damaging4.18Benign0.00Affected4.3210.10260.402512-0.414.03
c.1159G>T
G387C
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G387C is not reported in ClinVar (ClinVar ID None) but is present in gnomAD (ID 6‑33438064‑G‑T). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, AlphaMissense‑Default, AlphaMissense‑Optimized, and polyPhen‑2 HumVar. Those that predict a pathogenic effect are FoldX, Rosetta, Foldetta, polyPhen‑2 HumDiv, SIFT, and FATHMM; ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as pathogenic. Overall, the majority of high‑confidence tools lean toward a benign interpretation, and this does not contradict the ClinVar status, which has no pathogenic classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.642678Disordered0.422910Uncertain0.2930.8610.7506-33438064-G-T16.21e-7-7.609In-Between0.146Likely BenignLikely Benign2.88Destabilizing0.62.34Destabilizing2.61Destabilizing-0.03Likely Benign0.430Likely Benign-0.58Neutral0.859Possibly Damaging0.346Benign1.32Pathogenic0.01Affected4.3230.15890.4240-3-32.946.09
c.1227G>A
M409I
2D
AISynGAP1 missense variant M409I is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster into two groups: benign (REVEL, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score of Likely Benign) and pathogenic (polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default). High‑accuracy assessments reinforce the benign trend: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields benign, and Foldetta, which integrates FoldX‑MD and Rosetta outputs, reports a benign effect. FoldX and Rosetta individually give uncertain results and are treated as unavailable. Overall, the majority of reliable predictors indicate a benign impact for M409I. Thus, the variant is most likely benign, and this conclusion does not contradict the lack of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.150080Structured0.360643Uncertain0.8840.2190.000-3.735Likely Benign0.598Likely PathogenicLikely Benign0.59Ambiguous0.8-0.79Ambiguous-0.10Likely Benign0.36Likely Benign0.162Likely Benign-0.58Neutral0.579Possibly Damaging0.663Possibly Damaging4.22Benign0.92Tolerated0.11050.3358212.6-18.03
c.1227G>C
M409I
2D
AISynGAP1 missense variant M409I is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster into two groups: benign (REVEL, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score of Likely Benign) and pathogenic (polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default). High‑accuracy assessments reinforce the benign trend: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields benign, and Foldetta, which integrates FoldX‑MD and Rosetta outputs, reports a benign effect. FoldX and Rosetta individually give uncertain results and are treated as unavailable. Overall, the majority of reliable predictors indicate a benign impact for M409I, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.150080Structured0.360643Uncertain0.8840.2190.000-3.735Likely Benign0.598Likely PathogenicLikely Benign0.59Ambiguous0.8-0.79Ambiguous-0.10Likely Benign0.36Likely Benign0.162Likely Benign-0.58Neutral0.579Possibly Damaging0.663Possibly Damaging4.22Benign0.92Tolerated0.11050.3358212.6-18.03
c.1227G>T
M409I
2D
AISynGAP1 missense variant M409I is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster into two groups: benign (REVEL, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score of Likely Benign) and pathogenic (polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default). High‑accuracy assessments reinforce the benign trend: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields benign, and Foldetta, which integrates FoldX‑MD and Rosetta outputs, reports a benign effect. FoldX and Rosetta individually give uncertain results and are treated as unavailable. Overall, the majority of reliable predictors indicate a benign impact for M409I, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.150080Structured0.360643Uncertain0.8840.2190.000-3.735Likely Benign0.598Likely PathogenicLikely Benign0.59Ambiguous0.8-0.79Ambiguous-0.10Likely Benign0.36Likely Benign0.162Likely Benign-0.58Neutral0.579Possibly Damaging0.663Possibly Damaging4.22Benign0.92Tolerated0.11050.3358212.6-18.03
c.122G>T
R41L
2D
AIThe SynGAP1 missense variant R41L is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates likely benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for R41L, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.311707Structured0.431757Uncertain0.3440.7650.375-3.173Likely Benign0.261Likely BenignLikely Benign0.111Likely Benign-0.58Neutral0.686Possibly Damaging0.630Possibly Damaging4.18Benign0.00Affected0.21340.5868-3-28.3-43.03
c.135C>A
N45K
2D
AISynGAP1 missense variant N45K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM‑Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a benign outcome; Foldetta results are unavailable. Overall, the balance of evidence—five benign versus four pathogenic predictions, with two high‑accuracy tools supporting benign—suggests that the variant is most likely benign. This conclusion does not contradict ClinVar status, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.401658Structured0.431853Uncertain0.4980.7410.375-1.711Likely Benign0.697Likely PathogenicLikely Benign0.082Likely Benign-0.58Neutral0.659Possibly Damaging0.775Possibly Damaging4.13Benign0.00Affected0.24090.672410-0.414.07
c.135C>G
N45K
2D
AISynGAP1 missense variant N45K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM‑Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a benign outcome; Foldetta results are unavailable. Overall, the balance of evidence—five benign versus four pathogenic predictions, with two high‑accuracy tools supporting benign—suggests that the variant is most likely benign. This conclusion does not contradict ClinVar status, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.401658Structured0.431853Uncertain0.4980.7410.375-1.711Likely Benign0.697Likely PathogenicLikely Benign0.082Likely Benign-0.58Neutral0.659Possibly Damaging0.775Possibly Damaging4.13Benign0.00Affected0.24090.672410-0.414.07
c.2017C>G
L673V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L673V is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic outcome are FoldX, Rosetta, Foldetta, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as Likely Benign, and Foldetta as pathogenic, yielding one pathogenic versus two benign predictions. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.060549Structured0.104692Uncertain0.5450.3690.000-8.132Likely Pathogenic0.099Likely BenignLikely Benign2.18Destabilizing0.32.10Destabilizing2.14Destabilizing0.10Likely Benign0.017Likely Benign-0.58Neutral0.016Benign0.003Benign3.36Benign0.28Tolerated0.14480.3777210.4-14.03
c.2236G>A
V746M
2D
AIThe SynGAP1 missense variant V746M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool in the dataset predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Overall, the consensus of available predictions strongly suggests that V746M is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.808535Disordered0.576597Binding0.3360.8670.875-4.194Likely Benign0.087Likely BenignLikely Benign0.010Likely Benign-0.58Neutral0.065Benign0.037Benign2.79Benign0.60Tolerated0.07560.457621-2.332.06
c.2371A>G
K791E
2D
AIThe SynGAP1 missense variant K791E is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools uniformly favor a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) indicates likely benign; Foldetta results are unavailable. Taken together, the preponderance of evidence supports a benign impact for K791E, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.966441Disordered0.478670Uncertain0.3560.8960.875-3.823Likely Benign0.465AmbiguousLikely Benign0.053Likely Benign-0.58Neutral0.451Benign0.193Benign4.22Benign0.65Tolerated0.48290.0876010.40.94
c.2495A>T
Q832L
2D
AIThe SynGAP1 missense variant Q832L is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign. Foldetta results are unavailable. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.720929Disordered0.619913Binding0.2900.8770.375-2.299Likely Benign0.190Likely BenignLikely Benign0.090Likely Benign-0.58Neutral0.811Possibly Damaging0.424Benign2.84Benign1.00Tolerated0.06760.4852-2-27.3-14.97
c.2648T>C
L883P
2D
AIThe SynGAP1 missense variant L883P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic effect. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence supports a benign classification for this variant, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.716283Disordered0.641952Binding0.3340.8860.250-2.572Likely Benign0.105Likely BenignLikely Benign0.074Likely Benign-0.58Neutral0.934Possibly Damaging0.516Possibly Damaging2.62Benign0.21Tolerated0.34620.1658-3-3-5.4-16.04
c.2650C>G
R884G
2D
AIThe SynGAP1 missense variant R884G is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign status. Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.720929Disordered0.641526Binding0.3050.8980.250-1.332Likely Benign0.183Likely BenignLikely Benign0.030Likely Benign-0.58Neutral0.000Benign0.002Benign2.64Benign0.27Tolerated0.35020.3655-3-24.1-99.14
c.2882A>C
H961P
2D
AIThe SynGAP1 missense variant H961P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign, while only SIFT and ESM1b predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a Likely Benign verdict (3 benign vs. 1 pathogenic). High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Consequently, the collective evidence indicates that H961P is most likely benign, and this conclusion is not in conflict with ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750-8.434Likely Pathogenic0.071Likely BenignLikely Benign0.210Likely Benign-0.58Neutral0.000Benign0.000Benign4.15Benign0.02Affected0.20610.47010-21.6-40.02
c.290A>C
E97A
2D
AIThe SynGAP1 missense variant E97A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain. High‑accuracy assessments reinforce the benign prediction: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is also likely benign. Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for E97A, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.609018Binding0.3400.8670.625-3.091Likely Benign0.374AmbiguousLikely Benign0.098Likely Benign-0.58Neutral0.880Possibly Damaging0.636Possibly Damaging4.16Benign0.00Affected0.45050.77280-15.3-58.04
c.2924C>A
T975N
2D
AIThe SynGAP1 missense variant T975N is listed in ClinVar (ID 942242.0) with an “Uncertain” clinical significance and is present in gnomAD (variant ID 6‑33443476‑C‑A). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign or tolerated outcomes. Only polyPhen‑2 HumDiv predicts a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, which is consistent with the ClinVar “Uncertain” status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.871313Disordered0.969331Binding0.3320.8900.625Uncertain 16-33443476-C-A16.20e-7-4.671Likely Benign0.089Likely BenignLikely Benign0.100Likely Benign-0.58Neutral0.586Possibly Damaging0.302Benign4.13Benign0.07Tolerated4.3220.13790.477200-2.813.00
c.2980A>G
K994E
2D
AIThe SynGAP1 missense variant K994E is reported in gnomAD (variant ID 6‑33443532‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the consensus of the majority of tools, including the high‑accuracy methods, points to a benign impact. This prediction does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.930054Binding0.2890.9120.7506-33443532-A-G16.20e-7-2.587Likely Benign0.339Likely BenignLikely Benign0.057Likely Benign-0.58Neutral0.036Benign0.039Benign4.14Benign0.02Affected4.3220.41480.1699100.40.94
c.2986C>T
P996S
2D
AIThe SynGAP1 missense variant P996S is reported in gnomAD (ID 6‑33443538‑C‑T) and has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions is benign, and this is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.775545Disordered0.942262Binding0.3120.9000.7506-33443538-C-T42.48e-6-4.461Likely Benign0.063Likely BenignLikely Benign0.064Likely Benign-0.58Neutral0.002Benign0.004Benign4.30Benign0.09Tolerated4.3240.31710.5161-110.8-10.04
c.3017A>C
Y1006S
2D
AIThe SynGAP1 missense variant Y1006S has no ClinVar record and is not listed in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, which has no entry for Y1006S.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.801317Disordered0.930554Binding0.2640.8960.750-2.522Likely Benign0.582Likely PathogenicLikely Benign0.170Likely Benign-0.58Neutral1.000Probably Damaging0.998Probably Damaging2.83Benign0.90Tolerated0.44260.2274-3-20.5-76.10
c.3179G>A
G1060D
2D
AIThe SynGAP1 missense variant G1060D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also leans benign (2 benign vs 1 pathogenic). Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.979242Disordered0.913048Binding0.4070.9280.875-9.824Likely Pathogenic0.342AmbiguousLikely Benign0.391Likely Benign-0.58Neutral0.905Possibly Damaging0.538Possibly Damaging2.63Benign0.20Tolerated0.17030.20351-1-3.158.04
c.3202T>G
L1068V
2D
AIThe SynGAP1 missense variant L1068V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.947281Disordered0.981041Binding0.3620.9070.875-5.325Likely Benign0.078Likely BenignLikely Benign0.051Likely Benign-0.58Neutral0.451Benign0.110Benign2.54Benign0.00Affected0.16190.4404210.4-14.03
c.3293G>A
S1098N
2D
AIThe SynGAP1 missense variant S1098N is listed in ClinVar (ID 864704.0) with an “Uncertain” clinical significance and is present in gnomAD (variant ID 6‑33443845‑G‑A). All evaluated in‑silico predictors agree on a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. No tool predicts pathogenicity. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status is unavailable. Overall, the computational evidence strongly supports a benign classification, which is consistent with the ClinVar “Uncertain” status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.973030Binding0.3370.8551.000Conflicting 26-33443845-G-A63.89e-6-5.120Likely Benign0.156Likely BenignLikely Benign0.063Likely Benign-0.58Neutral0.369Benign0.120Benign2.76Benign0.36Tolerated3.7750.16650.514511-2.727.03
c.3370G>A
G1124R
2D
AISynGAP1 missense variant G1124R is listed in ClinVar with an uncertain significance and is present in gnomAD (ID 6‑33443922‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b, while AlphaMissense‑Default remains uncertain. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, resolves to benign. High‑accuracy methods give AlphaMissense‑Optimized as benign; the SGM Consensus also supports benign. Foldetta, a protein‑folding stability predictor combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the ensemble of predictions leans toward a benign impact, which does not contradict the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.837511Disordered0.833401Binding0.3410.9310.875Conflicting 36-33443922-G-A241.60e-5-8.918Likely Pathogenic0.534AmbiguousLikely Benign0.243Likely Benign-0.58Neutral0.002Benign0.002Benign4.81Benign0.01Affected3.7750.09350.4332-3-2-4.199.14
c.3370G>C
G1124R
2D
AIThe SynGAP1 missense variant G1124R is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in silico predictors shows a predominance of benign calls: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized all predict a benign effect, while SIFT and ESM1b predict pathogenicity. The AlphaMissense‑Default tool is uncertain. High‑accuracy assessments reinforce the benign trend: AlphaMissense‑Optimized is benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also returns benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the balance of evidence points to a benign impact for G1124R, and this conclusion is consistent with the absence of any ClinVar annotation or gnomAD observation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.837511Disordered0.833401Binding0.3410.9310.875-8.918Likely Pathogenic0.534AmbiguousLikely Benign0.239Likely Benign-0.58Neutral0.002Benign0.002Benign4.81Benign0.01Affected3.7750.09350.4332-3-2-4.199.14
c.3952C>G
L1318V
2D
AIThe SynGAP1 missense variant L1318V is catalogued in gnomAD (ID 6‑33451826‑C‑G) but has no ClinVar entry. Across a broad panel of in silico predictors, every tool reports a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool in the set predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized returns a benign prediction, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status is unavailable. Overall, the computational evidence overwhelmingly supports a benign effect, and this is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign, and this assessment does not contradict the ClinVar record, which contains no pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.968271Binding0.3990.8650.7506-33451826-C-G16.31e-7-3.938Likely Benign0.091Likely BenignLikely Benign0.038Likely Benign-0.58Neutral0.113Benign0.028Benign4.08Benign0.75Tolerated3.7750.18610.3027120.4-14.03
c.4021G>A
A1341T
2D
AIThe SynGAP1 missense variant A1341T is listed in ClinVar (ID 837815.0) with an “Uncertain” clinical significance and is present in gnomAD (variant ID 6‑33451895‑G‑A). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign or likely benign. Only SIFT predicts a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for A1341T, which is consistent with the ClinVar “Uncertain” status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.823549Disordered0.980111Binding0.3830.6961.000Conflicting 36-33451895-G-A453.44e-5-3.224Likely Benign0.081Likely BenignLikely Benign0.099Likely Benign-0.58Neutral0.000Benign0.000Benign4.09Benign0.03Affected3.7750.18350.739110-2.530.03
c.4025A>C
D1342A
2D
AIThe SynGAP1 missense variant D1342A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized reports a benign effect, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are unavailable. Overall, the preponderance of evidence supports a benign classification for D1342A, and this conclusion does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.921076Disordered0.981682Binding0.3160.6780.875-2.719Likely Benign0.145Likely BenignLikely Benign0.049Likely Benign-0.58Neutral0.371Benign0.084Benign4.06Benign0.02Affected0.42700.56760-25.3-44.01
c.421A>G
I141V
2D
AIThe SynGAP1 I141V missense variant is catalogued in gnomAD (ID 6‑33432718‑A‑G) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM) and pathogenic (SIFT, AlphaMissense‑Default). The high‑accuracy AlphaMissense‑Optimized score is uncertain, and the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, favors a benign outcome. Foldetta, a protein‑folding stability predictor that integrates FoldX‑MD and Rosetta outputs, has no reported result for this variant. Overall, the preponderance of evidence points to a benign effect, and this assessment aligns with the lack of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.465241Structured0.577021Binding0.3670.8770.5006-33432718-A-G16.42e-7-4.030Likely Benign0.785Likely PathogenicAmbiguous0.125Likely Benign-0.58Neutral0.016Benign0.021Benign3.74Benign0.03Affected3.6150.11010.346434-0.3-14.03
c.49T>A
S17T
2D
AIThe SynGAP1 missense variant S17T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect. The variant is most likely benign, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.483068Structured0.452228Uncertain0.3410.9100.375-3.782Likely Benign0.197Likely BenignLikely Benign0.061Likely Benign-0.58Neutral0.052Benign0.004Benign4.10Benign0.00Affected0.16670.6933110.114.03
c.52T>C
Y18H
2D
AIThe SynGAP1 missense variant Y18H is listed in gnomAD (ID 6‑33420316‑T‑C) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.483068Structured0.446314Uncertain0.3450.9080.3756-33420316-T-C-2.871Likely Benign0.542AmbiguousLikely Benign0.045Likely Benign-0.58Neutral0.872Possibly Damaging0.114Benign4.07Benign0.00Affected4.3210.28050.099320-1.9-26.03
c.955G>T
A319S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A319S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM; ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta as benign. No prediction or stability result is missing or inconclusive. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.179055Structured0.410405Uncertain0.8790.2540.125-7.109In-Between0.093Likely BenignLikely Benign0.16Likely Benign0.20.02Likely Benign0.09Likely Benign0.13Likely Benign0.165Likely Benign-0.58Neutral0.978Probably Damaging0.754Possibly Damaging2.02Pathogenic0.12Tolerated0.25370.470311-2.616.00
c.1163G>C
G388A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G388A is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, premPS, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic outcome are FoldX, Rosetta, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, SGM‑Consensus as Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta stability outputs) as Pathogenic. Overall, the predictions are mixed, but the two most reliable tools (AlphaMissense‑Optimized and SGM‑Consensus) favor a benign interpretation, while Foldetta suggests instability. Based on the available predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.736850Disordered0.420316Uncertain0.3190.8270.750-6.577Likely Benign0.110Likely BenignLikely Benign2.55Destabilizing1.93.57Destabilizing3.06Destabilizing-0.04Likely Benign0.457Likely Benign-0.57Neutral0.953Possibly Damaging0.952Probably Damaging1.33Pathogenic0.05Affected0.39690.4837102.214.03
c.140G>A
R47Q
2D
AIThe SynGAP1 missense variant R47Q is listed in ClinVar (ID 436920.0) as Benign and is present in gnomAD (6‑33423549‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and Foldetta results are unavailable. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, the SGM‑Consensus as Benign, and no Foldetta data to influence the conclusion. Overall, the majority of evidence points to a benign impact, consistent with the ClinVar classification; there is no contradiction with the reported ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.318242Structured0.436559Uncertain0.5200.7190.125Likely Benign 16-33423549-G-A42.48e-6-4.989Likely Benign0.347AmbiguousLikely Benign0.096Likely Benign-0.57Neutral0.829Possibly Damaging0.614Possibly Damaging4.12Benign0.00Affected4.3210.33260.2591111.0-28.0610.1016/j.ajhg.2020.11.011
c.203T>C
L68P
2D
AIThe SynGAP1 missense variant L68P is not reported in ClinVar and is absent from gnomAD. Prediction tools that classify the variant as benign include REVEL, PROVEAN, ESM1b, FATHMM, and the SGM‑Consensus (Likely Benign). Tools that predict pathogenicity are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of predictions lean toward pathogenic, but the consensus from SGM and the high‑accuracy AlphaMissense‑Optimized are contradictory, leaving the variant’s clinical significance uncertain. No conflict exists with ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.470567Uncertain0.4050.7680.250-2.122Likely Benign0.956Likely PathogenicLikely Pathogenic0.143Likely Benign-0.57Neutral0.943Possibly Damaging0.766Possibly Damaging4.09Benign0.00Affected0.28270.1382-3-3-5.4-16.04
c.2119G>A
A707T
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant A707T is reported in gnomAD (ID 6‑33441584‑G‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is also benign. The Foldetta stability prediction is inconclusive and therefore not considered evidence. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.203355Structured0.371229Uncertain0.9270.3650.0006-33441584-G-A16.20e-7-0.836Likely Benign0.175Likely BenignLikely Benign0.50Ambiguous0.02.36Destabilizing1.43Ambiguous0.10Likely Benign0.252Likely Benign-0.57Neutral0.980Probably Damaging0.947Probably Damaging3.52Benign0.44Tolerated3.5090.08800.433001-2.530.03
c.2165G>C
S722T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S722T is reported in gnomAD (6‑33441630‑G‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts it as pathogenic, while FoldX is uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is benign; and Foldetta, which integrates FoldX‑MD and Rosetta outputs, also predicts benign. No prediction or stability result is missing or inconclusive. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.468512Structured0.457186Uncertain0.9500.4310.3756-33441630-G-C16.20e-7-5.734Likely Benign0.202Likely BenignLikely Benign0.53Ambiguous0.0-0.32Likely Benign0.11Likely Benign-0.12Likely Benign0.118Likely Benign-0.57Neutral0.921Possibly Damaging0.414Benign2.57Benign1.00Tolerated3.5080.13570.4363110.114.03
c.2230C>G
Q744E
2D
AIThe SynGAP1 missense variant Q744E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign,” while Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.540428Binding0.3160.8660.875-4.053Likely Benign0.100Likely BenignLikely Benign0.060Likely Benign-0.57Neutral0.065Benign0.038Benign2.77Benign0.08Tolerated0.14530.1892220.00.98
c.2387C>G
P796R
2D
AIThe SynGAP1 P796R missense change is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports it as “Likely Benign.” Only SIFT predicts a pathogenic outcome, and ESM1b remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Taken together, the overwhelming majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.936162Disordered0.426363Uncertain0.4270.9000.875-7.053In-Between0.191Likely BenignLikely Benign0.063Likely Benign-0.57Neutral0.002Benign0.002Benign4.28Benign0.01Affected0.15580.29340-2-2.959.07
c.2392C>G
P798A
2D
AIThe SynGAP1 missense variant P798A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: benign predictions come from REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized, whereas only polyPhen‑2 HumDiv and SIFT predict pathogenicity. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports benign, and the SGM‑Consensus also indicates benign. Foldetta results are not available, so they do not influence the assessment. Overall, the consensus of available predictions indicates that P798A is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.871313Disordered0.492709Uncertain0.4260.8990.875-4.841Likely Benign0.050Likely BenignLikely Benign0.045Likely Benign-0.57Neutral0.790Possibly Damaging0.353Benign4.27Benign0.00Affected0.30600.40301-13.4-26.04
c.2405G>C
G802A
2D
AIThe SynGAP1 missense variant G802A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a “Likely Benign” status. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that G802A is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.894241Disordered0.681966Binding0.2940.8980.625-3.584Likely Benign0.105Likely BenignLikely Benign0.039Likely Benign-0.57Neutral0.059Benign0.089Benign2.74Benign0.02Affected0.37790.4554102.214.03
c.2569A>G
S857G
2D
AIThe SynGAP1 missense variant S857G is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect for S857G, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.728858Disordered0.475747Uncertain0.2880.8260.375-4.316Likely Benign0.067Likely BenignLikely Benign0.124Likely Benign-0.57Neutral0.979Probably Damaging0.973Probably Damaging4.10Benign0.85Tolerated0.29630.5644100.4-30.03
c.2594C>A
A865D
2D
AIThe SynGAP1 missense variant A865D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.521092Disordered0.626222Binding0.2710.7880.250-4.635Likely Benign0.515AmbiguousLikely Benign0.123Likely Benign-0.57Neutral0.611Possibly Damaging0.346Benign2.71Benign0.36Tolerated0.15630.15600-2-5.344.01
c.2606T>A
L869Q
2D
AIThe SynGAP1 missense variant L869Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default remains uncertain, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.501700Disordered0.688653Binding0.2720.8390.250-2.925Likely Benign0.368AmbiguousLikely Benign0.160Likely Benign-0.57Neutral0.970Probably Damaging0.801Possibly Damaging2.60Benign0.06Tolerated0.09770.1203-2-2-7.314.97
c.2878C>A
H960N
2D
AIThe SynGAP1 missense variant H960N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987911Disordered0.983385Binding0.3800.9010.750-8.822Likely Pathogenic0.101Likely BenignLikely Benign0.130Likely Benign-0.57Neutral0.494Possibly Damaging0.129Benign4.19Benign0.40Tolerated0.21370.369521-0.3-23.04
c.2923A>T
T975S
2D
AIThe SynGAP1 missense variant T975S is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, is not available for this variant. Overall, the predictions strongly suggest that T975S is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.871313Disordered0.969331Binding0.3320.8900.625-2.743Likely Benign0.068Likely BenignLikely Benign0.127Likely Benign-0.57Neutral0.059Benign0.061Benign4.16Benign0.20Tolerated0.32280.436611-0.1-14.03
c.2924C>G
T975S
2D
AIThe SynGAP1 missense variant T975S is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool in the dataset predicts a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the available predictions strongly suggest that T975S is most likely benign, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.871313Disordered0.969331Binding0.3320.8900.625Uncertain 1-2.743Likely Benign0.068Likely BenignLikely Benign0.109Likely Benign-0.57Neutral0.059Benign0.061Benign4.16Benign0.20Tolerated0.32280.436611-0.1-14.03
c.2941G>A
G981S
2D
AIThe SynGAP1 missense variant G981S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; the Foldetta stability analysis is not available for this variant. Overall, the majority of evidence—including the consensus and high‑accuracy tools—points to a benign effect. This conclusion is not contradicted by ClinVar, which contains no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.798249Disordered0.970320Binding0.2750.8970.625-2.749Likely Benign0.274Likely BenignLikely Benign0.130Likely Benign-0.57Neutral0.979Probably Damaging0.907Possibly Damaging3.87Benign0.00Affected0.25660.547010-0.430.03
c.3157A>G
S1053G
2D
AIThe SynGAP1 missense variant S1053G is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions strongly suggests that S1053G is most likely benign, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.875-1.016Likely Benign0.050Likely BenignLikely Benign0.220Likely Benign-0.57Neutral0.001Benign0.002Benign5.32Benign0.59Tolerated0.27240.5046100.4-30.03
c.3203T>C
L1068S
2D
AIThe SynGAP1 missense variant L1068S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.947281Disordered0.981041Binding0.3620.9070.875-6.297Likely Benign0.211Likely BenignLikely Benign0.175Likely Benign-0.57Neutral0.032Benign0.017Benign2.59Benign0.00Affected0.28100.1853-3-2-4.6-26.08
c.3280T>A
S1094T
2D
AIThe SynGAP1 missense variant S1094T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.981352Binding0.3580.8771.000-4.009Likely Benign0.194Likely BenignLikely Benign0.077Likely Benign-0.57Neutral0.790Possibly Damaging0.433Benign2.59Benign0.16Tolerated0.18740.6902110.114.03
c.3400A>C
T1134P
2D
AIThe SynGAP1 missense variant T1134P is not reported in ClinVar and is absent from gnomAD. All evaluated in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. No tool predicts pathogenicity. The high‑accuracy consensus methods likewise support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are unavailable. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.885302Disordered0.813034Binding0.3350.8850.875-2.993Likely Benign0.098Likely BenignLikely Benign0.164Likely Benign-0.57Neutral0.013Benign0.022Benign5.41Benign0.07Tolerated0.20010.51650-1-0.9-3.99
c.359G>A
G120D
2D
AIThe SynGAP1 missense variant G120D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence overwhelmingly supports a benign classification, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.659993Binding0.3590.8870.750-3.483Likely Benign0.465AmbiguousLikely Benign0.037Likely Benign-0.57Neutral0.165Benign0.034Benign4.25Benign0.21Tolerated0.18470.20241-1-3.158.04
c.3644A>G
K1215R
2D
AIThe SynGAP1 missense variant K1215R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the substitution as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy methods reinforce the benign prediction: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign, with no Foldetta data to contradict. Overall, the majority of evidence points to a benign effect, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.497853Structured0.503613Binding0.8880.5680.375-5.652Likely Benign0.360AmbiguousLikely Benign0.106Likely Benign-0.57Neutral0.999Probably Damaging0.995Probably Damaging2.85Benign0.28Tolerated0.40510.058232-0.628.01
c.3970C>G
P1324A
2D
AIThe SynGAP1 missense variant P1324A is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the consensus of the majority of tools and the high‑accuracy predictions point to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.891961Disordered0.899181Binding0.4320.7930.875-4.416Likely Benign0.056Likely BenignLikely Benign0.030Likely Benign-0.57Neutral0.011Benign0.017Benign4.30Benign0.00Affected0.34890.37761-13.4-26.04
c.95C>T
T32I
2D
AIThe SynGAP1 missense variant T32I is reported in gnomAD (ID 6‑33423504‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus also reports likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign impact for T32I, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.437154Uncertain0.3490.8790.3756-33423504-C-T16.20e-7-3.689Likely Benign0.213Likely BenignLikely Benign0.024Likely Benign-0.57Neutral0.049Benign0.026Benign4.26Benign0.00Affected4.3210.10810.6403-105.212.05
c.1082A>G
Q361R
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant Q361R has no ClinVar entry and is not reported in gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, SIFT, premPS, PROVEAN, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and Rosetta; pathogenic predictions come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign; the SGM‑Consensus itself is benign; and Foldetta, which integrates FoldX‑MD (Uncertain) and Rosetta (Benign), yields a benign prediction. Overall, the consensus of available computational evidence indicates that the variant is most likely benign, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.305330Structured0.427593Uncertain0.9450.5340.250-6.898Likely Benign0.289Likely BenignLikely Benign-0.88Ambiguous0.0-0.07Likely Benign-0.48Likely Benign-0.20Likely Benign0.296Likely Benign-0.56Neutral0.987Probably Damaging0.953Probably Damaging1.71Pathogenic0.41Tolerated0.13210.295511-1.028.06
c.1651C>A
L551M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L551M is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33438894‑C‑A). Prediction tools that classify the variant as benign include FoldX, Rosetta, Foldetta, PROVEAN, SIFT, and AlphaMissense‑Optimized, while those that predict pathogenicity are REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. Two tools report an uncertain outcome: premPS and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic. Overall, the majority of predictions lean toward a benign effect, and this does not contradict the ClinVar “Uncertain” classification. Thus, the variant is most likely benign based on the current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.009977Structured0.006653Uncertain0.9600.2540.000Uncertain 16-33438894-C-A74.34e-6-9.937Likely Pathogenic0.480AmbiguousLikely Benign-0.07Likely Benign0.10.13Likely Benign0.03Likely Benign0.71Ambiguous0.544Likely Pathogenic-0.56Neutral1.000Probably Damaging1.000Probably Damaging-1.48Pathogenic0.06Tolerated3.37350.08380.270142-1.918.03246.5-18.60.00.00.30.0XPotentially BenignL551 is located on an α-helix (res. Ala533-Val560). The iso-butyl side chain of Leu551 hydrophobically packs with nearby hydrophobic residues such as Cys547, Phe652, Leu633, and Ile630 in the inter-helix space. In the variant simulations, the thioether side chain of Met551 can maintain similar hydrophobic interactions as Leu551 in the WT, thus causing no negative effect on the protein structure during the simulations.
c.2552C>G
P851R
2D
AIThe SynGAP1 missense variant P851R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools, polyPhen‑2 HumDiv and HumVar, predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.648219Disordered0.526893Binding0.3470.8190.625-4.154Likely Benign0.179Likely BenignLikely Benign0.136Likely Benign-0.56Neutral0.999Probably Damaging0.997Probably Damaging4.22Benign0.09Tolerated0.12520.38730-2-2.959.07
c.2872C>A
H958N
2D
AIThe SynGAP1 missense variant H958N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.976011Binding0.3710.9130.750-8.644Likely Pathogenic0.097Likely BenignLikely Benign0.110Likely Benign-0.56Neutral0.836Possibly Damaging0.232Benign4.17Benign1.00Tolerated0.23580.363821-0.3-23.04
c.3034C>A
P1012T
2D
AIThe SynGAP1 missense variant P1012T is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.894674Binding0.3190.8660.625-4.788Likely Benign0.081Likely BenignLikely Benign0.052Likely Benign-0.56Neutral0.369Benign0.171Benign2.84Benign0.14Tolerated0.13990.57300-10.93.99
c.3226T>G
L1076V
2D
AIThe SynGAP1 missense variant L1076V is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign, while Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.989617Binding0.3010.8920.750-3.615Likely Benign0.344AmbiguousLikely Benign0.097Likely Benign-0.56Neutral0.995Probably Damaging0.982Probably Damaging2.53Benign0.11Tolerated0.16320.3781210.4-14.03
c.3326T>A
L1109H
2D
AIThe SynGAP1 missense variant L1109H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.856457Disordered0.948334Binding0.3430.8930.875-4.353Likely Benign0.237Likely BenignLikely Benign0.134Likely Benign-0.56Neutral0.832Possibly Damaging0.499Possibly Damaging2.70Benign0.04Affected0.12500.1845-2-3-7.023.98
c.3376G>C
G1126R
2D
AIThe SynGAP1 missense variant G1126R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. Two tools—ESM1b and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is uncertain due to a 2‑to‑2 split between benign and uncertain calls; Foldetta’s protein‑folding stability analysis is unavailable. Overall, the balance of evidence leans toward a benign interpretation, and this conclusion does not contradict any ClinVar annotation because no ClinVar record exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.894241Disordered0.837209Binding0.3450.9180.875-7.760In-Between0.522AmbiguousLikely Benign0.345Likely Benign-0.56Neutral0.971Probably Damaging0.597Possibly Damaging4.77Benign0.01Affected0.09460.4532-3-2-4.199.14
c.3380G>A
G1127E
2D
AIThe SynGAP1 missense variant G1127E is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the remaining tools (ESM1b and AlphaMissense‑Default) are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a tie between benign and uncertain calls. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the evidence strongly points to a benign effect, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.899122Disordered0.852422Binding0.3440.9150.875-7.359In-Between0.422AmbiguousLikely Benign0.314Likely Benign-0.56Neutral0.224Benign0.091Benign4.88Benign0.15Tolerated0.13950.42440-2-3.172.06
c.3638A>G
N1213S
2D
AIThe SynGAP1 missense variant N1213S is listed in ClinVar as Benign (ClinVar ID 708250.0) and is present in the gnomAD database (gnomAD ID 6‑33446630‑A‑G). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). In contrast, PolyPhen‑2 (HumDiv and HumVar) predict a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, aligning with the ClinVar classification and indicating no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.580690Disordered0.521638Binding0.8880.5610.500Benign 16-33446630-A-G138.05e-6-4.086Likely Benign0.081Likely BenignLikely Benign0.094Likely Benign-0.56Neutral0.906Possibly Damaging0.551Possibly Damaging2.82Benign0.68Tolerated3.7750.26070.4591112.7-27.0310.1016/j.ajhg.2020.11.011
c.4024G>C
D1342H
2D
AIThe SynGAP1 missense variant D1342H is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and SIFT—suggest a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Overall, the consensus of available predictions indicates that D1342H is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.921076Disordered0.981682Binding0.3160.6780.875-3.765Likely Benign0.310Likely BenignLikely Benign0.039Likely Benign-0.56Neutral0.834Possibly Damaging0.400Benign4.00Benign0.02Affected0.23650.61771-10.322.05
c.527G>A
S176N
2D
AIThe SynGAP1 missense variant S176N is catalogued in gnomAD (ID 6‑33435169‑G‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only AlphaMissense‑Default predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none reported). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.562014Disordered0.466016Uncertain0.3800.5970.3756-33435169-G-A16.20e-7-6.286Likely Benign0.594Likely PathogenicLikely Benign0.070Likely Benign-0.56Neutral0.421Benign0.080Benign4.10Benign0.22Tolerated3.5460.09960.393011-2.727.03
c.53A>G
Y18C
2D
AIThe SynGAP1 missense variant Y18C is listed in ClinVar (ID 1967233) with an “Uncertain” status and is present in gnomAD (variant ID 6‑33420317‑A‑G). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The high‑accuracy consensus (SGM‑Consensus, derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome, and AlphaMissense‑Optimized also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, which does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.483068Structured0.446314Uncertain0.3450.9080.375Uncertain 26-33420317-A-G442.88e-5-2.658Likely Benign0.251Likely BenignLikely Benign0.102Likely Benign-0.56Neutral0.872Possibly Damaging0.206Benign4.04Benign0.00Affected4.3210.32930.24730-23.8-60.04
c.802A>G
I268V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I268V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. Predictions that are inconclusive or unavailable are FoldX, Rosetta, Foldetta, and premPS. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign, while Foldetta’s stability analysis is uncertain. Overall, the majority of reliable predictors indicate a benign impact, and this is consistent with the lack of ClinVar evidence; there is no contradiction with ClinVar status. Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.216401Structured0.314336Uncertain0.9510.2640.000-4.553Likely Benign0.147Likely BenignLikely Benign1.46Ambiguous0.00.95Ambiguous1.21Ambiguous0.71Ambiguous0.139Likely Benign-0.56Neutral0.958Probably Damaging0.970Probably Damaging2.15Pathogenic0.71Tolerated0.08450.248943-0.3-14.03
c.1133G>C
G378A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G378A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized; pathogenic predictions arise from FoldX, Rosetta, polyPhen‑2 (HumDiv and HumVar), and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, labels the variant as “Likely Benign.” High‑accuracy assessments further refine the picture: AlphaMissense‑Optimized predicts benign, SGM‑Consensus confirms a benign likelihood, while Foldetta—combining FoldX‑MD and Rosetta outputs—predicts a pathogenic effect on protein folding stability. Overall, the majority of evidence points toward a benign impact, and this conclusion is consistent with the absence of ClinVar annotation and gnomAD data. Thus, the variant is most likely benign, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.767246Disordered0.432858Uncertain0.3410.9150.625-6.450Likely Benign0.111Likely BenignLikely Benign5.06Destabilizing1.36.00Destabilizing5.53Destabilizing-0.04Likely Benign0.497Likely Benign-0.55Neutral0.999Probably Damaging0.981Probably Damaging1.33Pathogenic0.18Tolerated0.40620.4576102.214.03
c.1157G>C
G386A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense change G386A has no ClinVar entry and is not reported in gnomAD. Consensus predictions from multiple in‑silico tools cluster into two groups: benign (SGM‑Consensus, REVEL, premPS, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, polyPhen‑2 HumVar) and pathogenic (FoldX, polyPhen‑2 HumDiv, SIFT). Two tools report uncertainty: Rosetta and Foldetta. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is likely benign, while Foldetta’s stability analysis is inconclusive. Overall, the majority of evidence points to a benign effect for G386A. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.733139Disordered0.424156Uncertain0.3340.8980.750-6.453Likely Benign0.112Likely BenignLikely Benign2.14Destabilizing0.71.05Ambiguous1.60Ambiguous0.14Likely Benign0.331Likely Benign-0.55Neutral0.718Possibly Damaging0.332Benign3.93Benign0.05Affected0.38150.4868102.214.03
c.1169G>C
G390A
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant G390A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, premPS, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT, FATHMM, and Rosetta. The high‑accuracy assessment shows AlphaMissense‑Optimized as benign, the SGM Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as likely benign, and Foldetta (combining FoldX‑MD and Rosetta stability outputs) as pathogenic. FoldX alone is inconclusive. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation because no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.626927Disordered0.413274Uncertain0.3040.7630.875-6.768Likely Benign0.100Likely BenignLikely Benign1.96Ambiguous0.42.03Destabilizing2.00Destabilizing0.02Likely Benign0.402Likely Benign-0.55Neutral0.143Benign0.028Benign1.33Pathogenic0.05Affected0.41300.5053102.214.03
c.174G>A
M58I
2D
AIThe SynGAP1 missense variant M58I is not reported in ClinVar (ClinVar ID = None) but is present in gnomAD (ID = 6‑33423583‑G‑A). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Tools that predict a pathogenic effect are SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic, while the SGM‑Consensus remains likely benign; Foldetta results are unavailable. Overall, the majority of predictions lean toward a benign impact, and this is not contradicted by ClinVar status. Thus, based on the available evidence, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.188120Structured0.484415Uncertain0.5150.6650.0006-33423583-G-A16.20e-7-2.153Likely Benign0.971Likely PathogenicLikely Pathogenic0.078Likely Benign-0.55Neutral0.006Benign0.091Benign4.21Benign0.00Affected4.3210.13970.3848122.6-18.03
c.174G>C
M58I
2D
AIThe SynGAP1 missense variant M58I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Tools that predict a pathogenic effect are SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict ClinVar status, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.188120Structured0.484415Uncertain0.5150.6650.000-2.153Likely Benign0.971Likely PathogenicLikely Pathogenic0.078Likely Benign-0.55Neutral0.006Benign0.091Benign4.21Benign0.00Affected4.3210.13970.3848122.6-18.03
c.174G>T
M58I
2D
AIThe SynGAP1 missense variant M58I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Tools that predict a pathogenic effect are SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome; Foldetta results are unavailable. Overall, the majority of predictions (seven benign vs. three pathogenic) suggest the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.188120Structured0.484415Uncertain0.5150.6650.000-2.153Likely Benign0.971Likely PathogenicLikely Pathogenic0.078Likely Benign-0.55Neutral0.006Benign0.091Benign4.21Benign0.00Affected4.3210.13970.3848122.6-18.03
c.2101C>G
P701A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant P701A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; all of these classify the substitution as benign. No tool predicts a pathogenic outcome. Predictions that are inconclusive are FoldX (uncertain) and Foldetta (uncertain). High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also predicts benign, while Foldetta remains uncertain. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.074921Structured0.404318Uncertain0.9180.3450.000-6.836Likely Benign0.217Likely BenignLikely Benign1.35Ambiguous0.00.23Likely Benign0.79Ambiguous-0.16Likely Benign0.058Likely Benign-0.55Neutral0.002Benign0.011Benign3.50Benign0.82Tolerated0.31430.37651-13.4-26.04
c.2203A>G
S735G
2D
AIThe SynGAP1 missense variant S735G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Based on the majority of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.916840Disordered0.412174Uncertain0.2900.7520.875-5.986Likely Benign0.083Likely BenignLikely Benign0.097Likely Benign-0.55Neutral0.953Possibly Damaging0.744Possibly Damaging2.68Benign0.23Tolerated0.27770.4089100.4-30.03
c.2265G>A
M755I
2D
AIThe SynGAP1 missense variant M755I is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.490133Structured0.783855Binding0.3360.8730.375-3.856Likely Benign0.240Likely BenignLikely Benign0.030Likely Benign-0.55Neutral0.039Benign0.014Benign2.81Benign0.14Tolerated0.10590.2403212.6-18.03
c.2265G>C
M755I
2D
AIThe SynGAP1 missense variant M755I is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.490133Structured0.783855Binding0.3360.8730.375-3.856Likely Benign0.240Likely BenignLikely Benign0.031Likely Benign-0.55Neutral0.039Benign0.014Benign2.81Benign0.14Tolerated0.10590.2403212.6-18.03
c.2265G>T
M755I
2D
AIThe SynGAP1 missense variant M755I is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.490133Structured0.783855Binding0.3360.8730.375-3.856Likely Benign0.240Likely BenignLikely Benign0.030Likely Benign-0.55Neutral0.039Benign0.014Benign2.81Benign0.14Tolerated0.10590.2403212.6-18.03
c.2287C>A
L763I
2D
AIThe SynGAP1 missense variant L763I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for this variant, and there is no conflict with ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.380708Structured0.918636Binding0.3510.8650.125-4.803Likely Benign0.150Likely BenignLikely Benign0.052Likely Benign-0.55Neutral0.877Possibly Damaging0.675Possibly Damaging2.48Pathogenic0.31Tolerated0.08700.3367220.70.00
c.2546A>G
D849G
2D
AISynGAP1 missense variant D849G is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) indicates likely benign. Foldetta results are unavailable. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.712013Disordered0.554191Binding0.3190.8130.500-2.124Likely Benign0.168Likely BenignLikely Benign0.154Likely Benign-0.55Neutral0.393Benign0.140Benign4.17Benign0.00Affected0.46220.75871-13.1-58.04
c.2547T>A
D849E
2D
AIThe SynGAP1 missense variant D849E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.712013Disordered0.554191Binding0.3190.8130.500-2.911Likely Benign0.089Likely BenignLikely Benign0.087Likely Benign-0.55Neutral0.393Benign0.187Benign4.25Benign0.00Affected0.19550.7819320.014.03
c.2547T>G
D849E
2D
AIThe SynGAP1 missense variant D849E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.712013Disordered0.554191Binding0.3190.8130.500-2.911Likely Benign0.089Likely BenignLikely Benign0.087Likely Benign-0.55Neutral0.393Benign0.187Benign4.25Benign0.00Affected0.19550.7819320.014.03
c.2591C>G
A864G
2D
AIThe SynGAP1 missense variant A864G is not reported in ClinVar and is absent from gnomAD. In silico prediction tools that assess sequence conservation and structural impact (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized) all classify the change as benign. No tool in the dataset predicts pathogenicity. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates “Likely Benign.” Foldetta results are not available. Overall, the consensus of all available predictions points to a benign effect, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.549308Disordered0.611966Binding0.2690.7880.250-3.662Likely Benign0.080Likely BenignLikely Benign0.024Likely Benign-0.55Neutral0.003Benign0.004Benign2.55Benign0.16Tolerated0.23830.538810-2.2-14.03
c.2629C>A
L877M
2D
AIThe SynGAP1 missense variant L877M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while the two polyPhen‑2 scores (HumDiv and HumVar) predict pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and the Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact for this variant, and this conclusion is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.653063Disordered0.634010Binding0.2650.8750.250-6.266Likely Benign0.134Likely BenignLikely Benign0.068Likely Benign-0.55Neutral0.922Possibly Damaging0.776Possibly Damaging2.58Benign0.15Tolerated0.08130.353242-1.918.03
c.2638G>C
A880P
2D
AIThe SynGAP1 missense variant A880P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools, polyPhen‑2 HumDiv and HumVar, predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.621441Binding0.3090.8740.250-3.671Likely Benign0.105Likely BenignLikely Benign0.098Likely Benign-0.55Neutral0.971Probably Damaging0.693Possibly Damaging2.61Benign0.11Tolerated0.17440.41061-1-3.426.04
c.269T>G
V90G
2D
AIThe SynGAP1 missense variant V90G is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields a benign verdict. Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.570702Disordered0.542047Binding0.3430.8730.500-2.617Likely Benign0.358AmbiguousLikely Benign0.094Likely Benign-0.55Neutral0.024Benign0.208Benign4.00Benign0.00Affected0.20470.2936-1-3-4.6-42.08
c.2846G>T
G949V
2D
AIThe SynGAP1 missense variant G949V is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors a benign outcome. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988861Disordered0.874971Binding0.3650.9230.750-7.364In-Between0.102Likely BenignLikely Benign0.328Likely Benign-0.55Neutral0.992Probably Damaging0.834Possibly Damaging2.21Pathogenic0.01Affected0.14930.3165-1-34.642.08
c.2866T>C
S956P
2D
AIThe SynGAP1 missense variant S956P is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.957345Binding0.3640.9170.750-3.526Likely Benign0.082Likely BenignLikely Benign0.157Likely Benign-0.55Neutral0.000Benign0.001Benign1.95Pathogenic0.05Affected0.26700.53371-1-0.810.04
c.2872C>G
H958D
2D
AIThe SynGAP1 missense variant H958D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and ESM1b—suggest a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.976011Binding0.3710.9130.750-11.494Likely Pathogenic0.227Likely BenignLikely Benign0.200Likely Benign-0.55Neutral0.925Possibly Damaging0.232Benign4.16Benign0.55Tolerated0.27320.28661-1-0.3-22.05
c.3034C>G
P1012A
2D
AIThe SynGAP1 missense variant P1012A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.894674Binding0.3190.8660.625-4.038Likely Benign0.069Likely BenignLikely Benign0.035Likely Benign-0.55Neutral0.112Benign0.084Benign2.81Benign0.26Tolerated0.32720.49001-13.4-26.04
c.3052A>G
T1018A
2D
AIThe SynGAP1 missense variant T1018A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the lack of ClinVar annotation. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.959985Binding0.3480.8010.500-3.289Likely Benign0.087Likely BenignLikely Benign0.082Likely Benign-0.55Neutral0.001Benign0.004Benign2.34Pathogenic0.53Tolerated0.38590.3362102.5-30.03
c.3175G>A
G1059R
2D
AIThe SynGAP1 missense variant G1059R is listed in ClinVar with an uncertain significance and is present in the gnomAD database (ID 6‑33443727‑G‑A). Consensus among most in silico predictors leans toward a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized all report benign. In contrast, SIFT and ESM1b predict pathogenicity, while AlphaMissense‑Default remains uncertain. High‑accuracy assessment consolidates this view: AlphaMissense‑Optimized is benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields a benign classification. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its influence is unavailable. Overall, the preponderance of computational evidence supports a benign interpretation, which is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.983019Disordered0.898939Binding0.3990.9260.875Conflicting 26-33443727-G-A684.23e-5-8.452Likely Pathogenic0.376AmbiguousLikely Benign0.333Likely Benign-0.55Neutral0.001Benign0.001Benign2.53Benign0.00Affected4.3220.10520.4342-3-2-4.199.14
c.3175G>C
G1059R
2D
AIThe SynGAP1 missense variant G1059R is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in silico predictors shows a predominance of benign calls: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized all predict a benign effect, whereas SIFT and ESM1b predict pathogenicity; AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce this trend: AlphaMissense‑Optimized is benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also returns a benign prediction. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the balance of evidence points to a benign impact for G1059R, and this conclusion is consistent with the absence of any ClinVar annotation or gnomAD observation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.983019Disordered0.898939Binding0.3990.9260.875-8.452Likely Pathogenic0.376AmbiguousLikely Benign0.333Likely Benign-0.55Neutral0.001Benign0.001Benign2.53Benign0.00Affected4.3220.10520.4342-3-2-4.199.14
c.3368G>C
G1123A
2D
AIThe SynGAP1 missense variant G1123A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated methods. High‑accuracy tools confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.837511Disordered0.827246Binding0.3460.9340.875-6.720Likely Benign0.082Likely BenignLikely Benign0.240Likely Benign-0.55Neutral0.264Benign0.103Benign4.38Benign1.00Tolerated0.35440.4944102.214.03
c.3670C>A
L1224M
2D
AIThe SynGAP1 missense variant L1224M is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign) all indicate a tolerated change. In contrast, polyPhen‑2 (HumDiv and HumVar) and FATHMM predict a pathogenic impact. When focusing on high‑accuracy predictors, AlphaMissense‑Optimized remains benign and the SGM‑Consensus also supports a benign outcome; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this assessment does not conflict with ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.525368Disordered0.441554Uncertain0.8710.5430.500-5.614Likely Benign0.098Likely BenignLikely Benign0.085Likely Benign-0.55Neutral0.994Probably Damaging0.925Probably Damaging2.38Pathogenic0.18Tolerated0.06600.248642-1.918.03
c.3941C>A
P1314Q
2D
AIThe SynGAP1 missense variant P1314Q is listed in gnomAD (ID 6‑33451815‑C‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; pathogenic predictions come from polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus itself is benign. No Foldetta stability data are available, so folding‑stability evidence is unavailable. Overall, the preponderance of computational evidence indicates that P1314Q is most likely benign, and this conclusion is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.971592Binding0.4670.9030.7506-33451815-C-A-4.222Likely Benign0.104Likely BenignLikely Benign0.039Likely Benign-0.55Neutral0.618Possibly Damaging0.333Benign4.24Benign0.04Affected3.7750.16120.4588-10-1.931.01
c.5G>C
S2T
2D
AIThe SynGAP1 missense variant S2T is reported in gnomAD (variant ID 6‑33420269‑G‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign impact for S2T, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.543646Binding0.3820.9220.7506-33420269-G-C-4.443Likely Benign0.144Likely BenignLikely Benign0.051Likely Benign-0.55Neutral0.052Benign0.004Benign4.09Benign0.00Affected4.3210.15750.6954110.114.03
c.8G>C
R3T
2D
AIThe SynGAP1 missense variant R3T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.538167Disordered0.550331Binding0.3580.9200.875-3.693Likely Benign0.285Likely BenignLikely Benign0.053Likely Benign-0.55Neutral0.208Benign0.018Benign4.01Benign0.00Affected0.18090.5145-1-13.8-55.08
c.904T>A
S302T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S302T is not reported in ClinVar and is absent from gnomAD. All available in silico predictors classify the substitution as benign: REVEL, FoldX, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). No tool predicts pathogenicity. High‑accuracy assessments concur: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields Likely Benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also indicates a benign effect. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.414856Structured0.263489Uncertain0.6160.2580.375-4.742Likely Benign0.072Likely BenignLikely Benign0.20Likely Benign0.10.10Likely Benign0.15Likely Benign-0.08Likely Benign0.043Likely Benign-0.55Neutral0.037Benign0.042Benign4.16Benign0.15Tolerated0.17150.6886110.114.03
c.1145G>T
G382V
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant G382V has no ClinVar entry and is not reported in gnomAD. Functional prediction tools show a split opinion: benign predictions come from PROVEAN, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions are returned by REVEL, FoldX, Rosetta, Foldetta, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM, while premPS is uncertain. High‑accuracy assessments give a mixed signal: AlphaMissense‑Optimized predicts benign, SGM‑Consensus indicates likely benign, but Foldetta (combining FoldX‑MD and Rosetta outputs) predicts pathogenic. Overall, the majority of tools lean toward pathogenicity, and the high‑accuracy Foldetta result supports this. Therefore, the variant is most likely pathogenic based on current predictions, and this assessment does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.728858Disordered0.429690Uncertain0.3150.9510.750-5.988Likely Benign0.155Likely BenignLikely Benign6.40Destabilizing1.69.28Destabilizing7.84Destabilizing-0.53Ambiguous0.571Likely Pathogenic-0.54Neutral0.994Probably Damaging0.990Probably Damaging1.32Pathogenic0.03Affected0.16310.3708-1-34.642.08
c.1159G>C
G387R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G387R is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that classify the variant as benign include premPS, PROVEAN, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. Tools that predict pathogenicity are SGM‑Consensus, REVEL, FoldX, Rosetta, Foldetta, SIFT, ESM1b, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized predicts a benign effect, SGM‑Consensus (a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) predicts likely pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts pathogenic. No predictions are missing or inconclusive. Overall, the majority of evidence (10 pathogenic vs. 4 benign) indicates the variant is most likely pathogenic, and this conclusion does not contradict the ClinVar status, which is currently unreported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicC20.642678Disordered0.422910Uncertain0.2930.8610.750-8.728Likely Pathogenic0.683Likely PathogenicLikely Benign4.13Destabilizing2.92.57Destabilizing3.35Destabilizing0.15Likely Benign0.516Likely Pathogenic-0.54Neutral0.003Benign0.004Benign1.32Pathogenic0.01Affected0.13090.4356-3-2-4.199.14
c.1160G>T
G387V
2D
3DClick to see structure in 3D Viewer
AISynGAP1 G387V is listed in ClinVar with an uncertain significance and is present in gnomAD (variant ID 6-33438065-G-T). Functional prediction tools that report a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are FoldX, Rosetta, SIFT, and FATHMM. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as likely benign, while the Foldetta stability assessment (combining FoldX‑MD and Rosetta) indicates a pathogenic change. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as likely benign, and Foldetta as pathogenic. Overall, the majority of predictions favor a benign impact, and this consensus does not contradict the ClinVar uncertain status; thus the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.642678Disordered0.422910Uncertain0.2930.8610.750Uncertain 16-33438065-G-T221.37e-5-6.199Likely Benign0.153Likely BenignLikely Benign5.13Destabilizing1.86.44Destabilizing5.79Destabilizing-0.33Likely Benign0.390Likely Benign-0.54Neutral0.069Benign0.077Benign1.32Pathogenic0.01Affected4.3230.15860.3708-1-34.642.08207.7-68.4-0.70.8-0.50.1UncertainGly387 is located in the Gly-rich Ω loop (res. Pro364-Pro398) between two anti-parallel β sheet strands (res. Thr359-Pro364 and res. Ala399-Ile411). The Ω loop is assumed to directly interact with the membrane, and it is observed to move arbitrarily throughout the WT solvent simulations. This loop potentially plays a crucial role in the SynGAP-membrane complex association, stability, and dynamics. However, this aspect cannot be fully addressed through solvent simulations alone.Ω loops are known to play significant roles in protein functions that require flexibility, and thus hydrophobic residues like valine are rarely tolerated. Although no negative structural effects are visualized in the variant’s simulations, Val387 may exert drastic effects on the SynGAP-membrane complex dynamics and stability. Since the effects on the Gly-rich Ω loop dynamics can only be well studied through the SynGAP-membrane complex, no definite conclusions can be drawn.
c.1171G>A
G391S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G391S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, and FoldX. Rosetta and Foldetta give uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus also as likely benign, while Foldetta remains uncertain. Overall, the majority of evidence points to a benign impact for G391S, and this conclusion does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.637480Disordered0.409509Uncertain0.2790.7410.750-5.531Likely Benign0.096Likely BenignLikely Benign2.14Destabilizing0.61.01Ambiguous1.58Ambiguous0.06Likely Benign0.462Likely Benign-0.54Neutral0.978Probably Damaging0.777Possibly Damaging1.33Pathogenic0.35Tolerated0.28200.509710-0.430.03
c.191T>G
I64R
2D
AIThe SynGAP1 missense variant I64R is not reported in ClinVar and has no entry in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), which classifies the variant as “Likely Benign.” Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. The high‑accuracy AlphaMissense‑Optimized score is uncertain, and the Foldetta protein‑folding stability assessment is unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the absence of a ClinVar assertion, so there is no contradiction with existing clinical database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.422041Structured0.475481Uncertain0.4780.7470.125-2.108Likely Benign0.936Likely PathogenicAmbiguous0.165Likely Benign-0.54Neutral0.842Possibly Damaging0.068Benign4.05Benign0.00Affected0.11030.0940-2-3-9.043.03
c.2221C>A
P741T
2D
AIThe SynGAP1 missense variant P741T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.885302Disordered0.493550Uncertain0.3540.8590.875-4.626Likely Benign0.061Likely BenignLikely Benign0.077Likely Benign-0.54Neutral0.010Benign0.022Benign2.86Benign0.05Affected0.12090.50800-10.93.99
c.2273A>C
Y758S
2D
AIThe SynGAP1 missense variant Y758S is reported in gnomAD (variant ID 6‑33441738‑A‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict it to be pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority‑vote) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Overall, the preponderance of evidence points to a benign impact, and this assessment does not contradict any ClinVar classification (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.517562Disordered0.856063Binding0.2890.8710.3756-33441738-A-C16.20e-7-1.912Likely Benign0.215Likely BenignLikely Benign0.110Likely Benign-0.54Neutral0.912Possibly Damaging0.629Possibly Damaging2.75Benign0.06Tolerated3.9950.53770.1663Weaken-2-30.5-76.10
c.2315T>A
F772Y
2D
AIThe SynGAP1 missense variant F772Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical databases.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.450668Structured0.922662Binding0.3290.8840.250-2.657Likely Benign0.117Likely BenignLikely Benign0.114Likely Benign-0.54Neutral0.705Possibly Damaging0.786Possibly Damaging4.17Benign0.35Tolerated0.10580.189273-4.116.00
c.2349G>A
M783I
2D
AIThe SynGAP1 missense variant M783I is listed in ClinVar as a benign alteration (ClinVar ID 3618151.0) and is present in the gnomAD database (gnomAD ID 6‑33442901‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). No tool in the dataset predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a likely benign effect. The Foldetta protein‑folding stability analysis is not available for this variant. Overall, the computational evidence strongly suggests that the variant is most likely benign, in agreement with its ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.736850Disordered0.738119Binding0.3310.8890.625Benign 16-33442901-G-A63.72e-6-3.560Likely Benign0.418AmbiguousLikely Benign0.042Likely Benign-0.54Neutral0.004Benign0.006Benign2.87Benign0.22Tolerated3.6460.15400.3710122.6-18.03
c.2349G>C
M783I
2D
AIThe SynGAP1 missense variant M783I is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Consensus from multiple in‑silico predictors classifies the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all return benign scores, and AlphaMissense‑Optimized also predicts a benign effect. No tool in the set indicates pathogenicity. The high‑accuracy assessments corroborate this view: AlphaMissense‑Optimized reports a benign outcome, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a Likely Benign classification, and Foldetta data are unavailable. Consequently, the aggregate evidence strongly supports a benign interpretation for M783I, and this conclusion does not conflict with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.736850Disordered0.738119Binding0.3310.8890.625-3.560Likely Benign0.418AmbiguousLikely Benign0.042Likely Benign-0.54Neutral0.004Benign0.006Benign2.87Benign0.22Tolerated3.6460.15400.3710122.6-18.03
c.2349G>T
M783I
2D
AIThe SynGAP1 missense variant M783I is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools uniformly indicate a benign effect. Benign calls are made by REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts pathogenicity; AlphaMissense‑Default remains uncertain. The high‑accuracy AlphaMissense‑Optimized score is benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports a likely benign outcome. Foldetta stability analysis is unavailable, so it does not influence the assessment. Overall, the computational evidence strongly supports a benign classification for M783I, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.736850Disordered0.738119Binding0.3310.8890.625-3.560Likely Benign0.418AmbiguousLikely Benign0.042Likely Benign-0.54Neutral0.004Benign0.006Benign2.87Benign0.22Tolerated3.6460.15400.3710122.6-18.03
c.2464A>T
T822S
2D
AIThe SynGAP1 missense variant T822S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for T822S, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.651624Binding0.2950.8810.750-1.710Likely Benign0.655Likely PathogenicLikely Benign0.107Likely Benign-0.54Neutral0.998Probably Damaging0.949Probably Damaging3.08Benign0.74Tolerated0.37940.454711-0.1-14.03
c.2749C>T
P917S
2D
AIThe SynGAP1 missense variant P917S is catalogued in gnomAD (ID 6‑33443301‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign. Only SIFT predicts pathogenicity. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, labels the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no reported result for this variant, so it provides no additional evidence. Overall, the preponderance of predictions indicates that P917S is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.599170Disordered0.863949Binding0.3140.8620.3756-33443301-C-T16.20e-7-3.562Likely Benign0.073Likely BenignLikely Benign0.056Likely Benign-0.54Neutral0.003Benign0.002Benign2.70Benign0.00Affected3.7750.34780.5121-110.8-10.04
c.313T>A
S105T
2D
AIThe SynGAP1 missense variant S105T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus, SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a benign effect. AlphaMissense‑Optimized independently scores the variant as benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.669201Binding0.3640.8700.625-4.166Likely Benign0.132Likely BenignLikely Benign0.055Likely Benign-0.54Neutral0.012Benign0.007Benign4.06Benign0.00Affected0.15830.5212110.114.03
c.3142G>A
G1048R
2D
AIThe SynGAP1 missense variant G1048R is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Functional prediction tools show a split: pathogenic calls come from REVEL, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar, whereas benign calls are made by PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus, derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a benign majority, and AlphaMissense‑Optimized itself predicts benign. The SGM‑Consensus, which aggregates these four predictors, reports a likely benign classification. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the absence of a ClinVar assertion; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.923876Binding0.3460.9160.750-4.305Likely Benign0.435AmbiguousLikely Benign0.503Likely Pathogenic-0.54Neutral0.919Possibly Damaging0.728Possibly Damaging2.54Benign0.10Tolerated3.7750.09560.4332-2-3-4.199.14
c.3142G>C
G1048R
2D
AIThe SynGAP1 missense variant G1048R is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Prediction tools that agree on a benign effect include PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are REVEL, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. The high‑accuracy AlphaMissense‑Optimized score is benign, and the SGM‑Consensus also indicates a likely benign outcome; the Foldetta protein‑folding stability assessment is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.923876Binding0.3460.9160.750Uncertain 1-4.305Likely Benign0.435AmbiguousLikely Benign0.503Likely Pathogenic-0.54Neutral0.919Possibly Damaging0.728Possibly Damaging2.54Benign0.10Tolerated3.7750.09560.4332-2-3-4.199.14
c.3158G>A
S1053N
2D
AIThe SynGAP1 missense variant S1053N is reported in gnomAD (variant ID 6‑33443710‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts it as pathogenic, while the consensus score from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus also indicates a likely benign outcome. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.8756-33443710-G-A16.21e-7-6.282Likely Benign0.120Likely BenignLikely Benign0.208Likely Benign-0.54Neutral0.625Possibly Damaging0.193Benign5.30Benign0.34Tolerated3.7750.19530.460511-2.727.03
c.3221A>G
Q1074R
2D
AIThe SynGAP1 missense variant Q1074R is listed in gnomAD (ID 6‑33443773‑A‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only AlphaMissense‑Default predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar status (none reported). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.987006Binding0.3390.8970.7506-33443773-A-G-5.710Likely Benign0.594Likely PathogenicLikely Benign0.124Likely Benign-0.54Neutral0.292Benign0.157Benign2.70Benign0.28Tolerated3.7750.15230.264311-1.028.06
c.3233T>G
V1078G
2D
AIThe SynGAP1 missense variant V1078G is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is benign (3 benign vs 1 pathogenic). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of evidence indicates a benign impact. This conclusion is not contradicted by ClinVar status, which has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.882776Disordered0.986989Binding0.2940.8980.750-3.270Likely Benign0.699Likely PathogenicLikely Benign0.168Likely Benign-0.54Neutral0.157Benign0.292Benign3.85Benign0.00Affected0.20410.2693-1-3-4.6-42.08
c.3310C>G
P1104A
2D
AIThe SynGAP1 missense variant P1104A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.936162Disordered0.954801Binding0.4400.8630.875-3.677Likely Benign0.059Likely BenignLikely Benign0.041Likely Benign-0.54Neutral0.409Benign0.184Benign2.74Benign0.22Tolerated0.32890.53151-13.4-26.04
c.3373G>A
G1125R
2D
AIThe SynGAP1 missense variant G1125R is catalogued in gnomAD (ID 6‑33443925‑G‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. AlphaMissense‑Default remains uncertain. A high‑accuracy consensus (SGM) that aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN yields a benign majority vote. AlphaMissense‑Optimized also reports benign. No Foldetta stability assessment is available. Collectively, the majority of evidence points to a benign effect, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.834292Disordered0.835839Binding0.3390.9230.8756-33443925-G-A-8.463Likely Pathogenic0.542AmbiguousLikely Benign0.291Likely Benign-0.54Neutral1.000Probably Damaging0.999Probably Damaging4.56Benign0.04Affected3.7750.09800.4332-2-3-4.199.14
c.3373G>C
G1125R
2D
AIThe SynGAP1 missense variant G1125R is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33443925‑G‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized, whereas polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b all predict a pathogenic outcome; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields benign, and Foldetta’s protein‑folding stability result is unavailable. Overall, the balance of evidence, particularly from the high‑accuracy tools, indicates that the variant is most likely benign. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.834292Disordered0.835839Binding0.3390.9230.8756-33443925-G-C16.68e-7-8.463Likely Pathogenic0.542AmbiguousLikely Benign0.290Likely Benign-0.54Neutral1.000Probably Damaging0.999Probably Damaging4.56Benign0.04Affected3.7750.09800.4332-2-3-4.199.14
c.472C>G
Q158E
2D
AIThe SynGAP1 missense variant Q158E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign consensus. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.527565Binding0.2860.7500.375-11.133Likely Pathogenic0.196Likely BenignLikely Benign0.063Likely Benign-0.54Neutral0.143Benign0.078Benign4.20Benign0.09Tolerated0.14200.2223220.00.98
c.751A>G
K251E
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant K251E is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include premPS, PROVEAN, SIFT, and FATHMM, while those that agree on a pathogenic effect are REVEL, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and AlphaMissense‑Default. The remaining tools (FoldX, Rosetta, Foldetta, AlphaMissense‑Optimized) give uncertain results. High‑accuracy methods are likewise inconclusive: AlphaMissense‑Optimized is uncertain, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is a tie, and Foldetta is uncertain. Overall, the majority of available predictions lean toward pathogenicity, with a small but notable benign signal. Therefore, the variant is most likely pathogenic based on current computational evidence, and this assessment does not contradict any ClinVar annotation because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
PH0.447574Structured0.226632Uncertain0.7580.3120.125-12.812Likely Pathogenic0.906Likely PathogenicAmbiguous0.88Ambiguous0.20.99Ambiguous0.94Ambiguous0.40Likely Benign0.571Likely Pathogenic-0.54Neutral0.970Probably Damaging0.584Possibly Damaging5.80Benign0.46Tolerated0.39290.0860010.40.94
c.100T>C
Y34H
2D
AIThe SynGAP1 missense variant Y34H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for Y34H, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.529623Disordered0.435847Uncertain0.3030.8550.375-2.929Likely Benign0.315Likely BenignLikely Benign0.102Likely Benign-0.53Neutral0.824Possibly Damaging0.775Possibly Damaging4.15Benign0.00Affected0.26300.106202-1.9-26.03
c.1120T>G
S374A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S374A is reported in gnomAD (6‑33438025‑T‑G) and has no ClinVar entry. Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments—AlphaMissense‑Optimized, SGM‑Consensus, and Foldetta (combining FoldX‑MD and Rosetta outputs)—all indicate a benign effect. Based on the collective predictions, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.642678Disordered0.428948Uncertain0.3330.8120.6256-33438025-T-G-4.245Likely Benign0.082Likely BenignLikely Benign-0.08Likely Benign0.10.41Likely Benign0.17Likely Benign0.10Likely Benign0.122Likely Benign-0.53Neutral0.012Benign0.011Benign5.32Benign0.04Affected4.32130.50910.5774Strenghten112.6-16.00
c.1139G>C
G380A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G380A is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only FoldX predicts a pathogenic outcome, while Rosetta and Foldetta are benign or uncertain, respectively. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as benign, and Foldetta as uncertain. Overall, the overwhelming majority of evidence points to a benign effect, with no conflict with ClinVar status (which has no entry for this variant). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.724957Disordered0.432982Uncertain0.3160.9390.750-6.433Likely Benign0.107Likely BenignLikely Benign3.11Destabilizing1.0-0.15Likely Benign1.48Ambiguous-0.06Likely Benign0.422Likely Benign-0.53Neutral0.056Benign0.010Benign2.56Benign0.17Tolerated0.39150.4576102.214.03
c.1734G>C
E578D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant E578D is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) leans toward benign (2 benign vs 1 pathogenic votes), and Foldetta also predicts benign stability. No prediction or folding result is missing or inconclusive. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.059222Structured0.020971Uncertain0.9020.2400.000-4.366Likely Benign0.447AmbiguousLikely Benign0.46Likely Benign0.10.15Likely Benign0.31Likely Benign-0.05Likely Benign0.318Likely Benign-0.53Neutral0.989Probably Damaging0.979Probably Damaging-1.43Pathogenic0.33Tolerated0.15610.3554320.0-14.03
c.1734G>T
E578D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 E578D missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) resolves to benign (2 benign vs 1 pathogenic votes), and Foldetta predicts a benign stability change. No prediction or stability result is missing or inconclusive. Overall, the majority of evidence indicates that the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.059222Structured0.020971Uncertain0.9020.2400.000-4.366Likely Benign0.447AmbiguousLikely Benign0.46Likely Benign0.10.15Likely Benign0.31Likely Benign-0.05Likely Benign0.318Likely Benign-0.53Neutral0.989Probably Damaging0.979Probably Damaging-1.43Pathogenic0.33Tolerated0.15610.3554320.0-14.03
c.2213G>A
S738N
2D
AIThe SynGAP1 missense variant S738N is reported in ClinVar as having no entry and is not present in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus, derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a benign majority vote, matching the SGM‑Consensus label of “Likely Benign.” Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this assessment is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.441162Uncertain0.2840.8270.875-5.005Likely Benign0.075Likely BenignLikely Benign0.059Likely Benign-0.53Neutral0.425Benign0.233Benign2.69Benign0.02Affected0.12840.325111-2.727.03
c.221G>C
S74T
2D
AIThe SynGAP1 missense variant S74T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and AlphaMissense‑Optimized also reports a benign prediction. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.505461Disordered0.450156Uncertain0.2940.8310.500-3.874Likely Benign0.072Likely BenignLikely Benign0.047Likely Benign-0.53Neutral0.000Benign0.000Benign4.22Benign0.00Affected0.15730.4704110.114.03
c.2275A>C
M759L
2D
AIThe SynGAP1 missense variant M759L is listed in ClinVar with an uncertain significance (ClinVar ID 942432.0) and is present in gnomAD (gnomAD ID 6‑33441740‑A‑C). All evaluated in‑silico predictors agree on a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign classifications. No tool predicts pathogenicity. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence strongly supports a benign impact, which is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.525368Disordered0.879389Binding0.2990.8640.375Uncertain 16-33441740-A-C21.24e-6-2.431Likely Benign0.093Likely BenignLikely Benign0.048Likely Benign-0.53Neutral0.002Benign0.005Benign2.84Benign1.00Tolerated3.9950.13080.4005421.9-18.03
c.2275A>T
M759L
2D
AIThe SynGAP1 missense variant M759L is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.525368Disordered0.879389Binding0.2990.8640.375-2.431Likely Benign0.093Likely BenignLikely Benign0.048Likely Benign-0.53Neutral0.002Benign0.005Benign2.84Benign1.00Tolerated3.9950.13080.4005421.9-18.03
c.2393C>A
P798Q
2D
AIThe SynGAP1 missense variant P798Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect for P798Q, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.871313Disordered0.492709Uncertain0.4260.8990.875-5.944Likely Benign0.074Likely BenignLikely Benign0.068Likely Benign-0.53Neutral0.988Probably Damaging0.780Possibly Damaging4.25Benign0.00Affected0.12900.38640-1-1.931.01
c.2437C>A
L813M
2D
AIThe SynGAP1 missense variant L813M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic effect. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus remains likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign impact for the variant, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.411940Structured0.838481Binding0.2920.9050.250-4.893Likely Benign0.299Likely BenignLikely Benign0.101Likely Benign-0.53Neutral0.999Probably Damaging0.985Probably Damaging2.58Benign0.23Tolerated0.08140.392242-1.918.03
c.2702C>A
A901E
2D
AIThe SynGAP1 missense variant A901E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, while Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.595080Disordered0.489838Uncertain0.3060.9170.375-4.350Likely Benign0.802Likely PathogenicAmbiguous0.082Likely Benign-0.53Neutral0.800Possibly Damaging0.300Benign2.64Benign0.12Tolerated0.14330.24240-1-5.358.04
c.2720G>C
S907T
2D
AIThe SynGAP1 missense variant S907T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. The only tools that predict a pathogenic outcome are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.637480Disordered0.661854Binding0.3360.9200.250-4.794Likely Benign0.220Likely BenignLikely Benign0.178Likely Benign-0.53Neutral0.992Probably Damaging0.846Possibly Damaging2.66Benign0.93Tolerated0.13240.6352110.114.03
c.2768T>C
I923T
2D
AIThe SynGAP1 missense variant I923T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as “Uncertain” and the SGM‑Consensus as “Likely Benign”; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.562014Disordered0.964857Binding0.2920.8520.250-1.180Likely Benign0.842Likely PathogenicAmbiguous0.097Likely Benign-0.53Neutral0.837Possibly Damaging0.348Benign2.73Benign0.41Tolerated0.13270.17860-1-5.2-12.05
c.3024T>A
D1008E
2D
AIThe SynGAP1 D1008E missense variant is catalogued in gnomAD (6‑33443576‑T‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). In contrast, polyPhen‑2 HumDiv and HumVar both predict a pathogenic outcome. AlphaMissense‑Default remains uncertain, providing no definitive signal. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus also reports it as likely benign. No Foldetta stability analysis is available, so it does not influence the overall assessment. Based on the preponderance of evidence from both general and high‑accuracy predictors, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.694846Disordered0.919416Binding0.2800.8990.6256-33443576-T-A16.20e-7-2.809Likely Benign0.428AmbiguousLikely Benign0.151Likely Benign-0.53Neutral0.997Probably Damaging0.994Probably Damaging2.93Benign1.00Tolerated3.7750.23150.6303230.014.03
c.3024T>G
D1008E
2D
AIThe SynGAP1 missense variant D1008E is listed in gnomAD (ID 6‑33443576‑T‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and Foldetta results are unavailable. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta provides no data. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.694846Disordered0.919416Binding0.2800.8990.6256-33443576-T-G-2.809Likely Benign0.428AmbiguousLikely Benign0.151Likely Benign-0.53Neutral0.997Probably Damaging0.994Probably Damaging2.93Benign1.00Tolerated3.7750.23150.6303230.014.03
c.3248A>G
K1083R
2D
AIThe SynGAP1 missense variant K1083R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. The variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.837511Disordered0.978906Binding0.3020.8931.000-2.212Likely Benign0.132Likely BenignLikely Benign0.119Likely Benign-0.53Neutral0.997Probably Damaging0.989Probably Damaging4.06Benign0.84Tolerated0.50530.1903Weaken32-0.628.01
c.3353G>A
S1118N
2D
AIThe SynGAP1 missense variant S1118N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods indicates that the variant is most likely benign, and this assessment is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.828802Binding0.3100.9190.750-6.551Likely Benign0.102Likely BenignLikely Benign0.223Likely Benign-0.53Neutral0.901Possibly Damaging0.433Benign5.26Benign0.06Tolerated0.19240.421511-2.727.03
c.3361A>G
S1121G
2D
AIThe SynGAP1 missense variant S1121G is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443913‑A‑G). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is also benign. Foldetta results are not available. Overall, the preponderance of evidence indicates that the variant is most likely benign, which does not contradict the current ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.894241Disordered0.810024Binding0.3650.9350.875Uncertain 16-33443913-A-G17.00e-7-1.220Likely Benign0.054Likely BenignLikely Benign0.067Likely Benign-0.53Neutral0.003Benign0.004Benign6.63Benign0.00Affected3.7750.27240.4657010.4-30.03
c.3610T>A
S1204T
2D
AIThe SynGAP1 missense variant S1204T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates “Likely Benign.” In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic impact. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is “Likely Benign.” Foldetta results are unavailable, so they do not influence the overall assessment. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar classification (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.595080Disordered0.541098Binding0.8870.5870.375-5.056Likely Benign0.176Likely BenignLikely Benign0.292Likely Benign-0.53Neutral0.826Possibly Damaging0.551Possibly Damaging5.42Benign0.94Tolerated0.14660.4510110.114.03
c.3610T>G
S1204A
2D
AIThe SynGAP1 missense variant S1204A is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a neutral effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.595080Disordered0.541098Binding0.8870.5870.375-5.134Likely Benign0.144Likely BenignLikely Benign0.213Likely Benign-0.53Neutral0.061Benign0.047Benign5.45Benign1.00Tolerated0.49430.3167112.6-16.00
c.41C>T
P14L
2D
AIThe SynGAP1 missense variant P14L is catalogued in gnomAD (ID 6‑33420305‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign or tolerated outcomes, while the single pathogenic call comes from SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign classification. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise favors benign; Foldetta results are unavailable. Overall, the consensus of available predictions points to a benign impact for P14L, and this conclusion is not contradicted by ClinVar status, which currently lacks an entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.433034Structured0.471596Uncertain0.3990.9090.3756-33420305-C-T-3.277Likely Benign0.332Likely BenignLikely Benign0.153Likely Benign-0.53Neutral0.062Benign0.004Benign4.19Benign0.00Affected4.3210.26180.7197-3-35.416.04
c.97C>A
Q33K
2D
AIThe SynGAP1 missense variant Q33K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the lack of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.436712Uncertain0.3420.8600.375-0.317Likely Benign0.217Likely BenignLikely Benign0.026Likely Benign-0.53Neutral0.019Benign0.021Benign4.24Benign0.00Affected0.23660.451411-0.40.04
c.9G>C
R3S
2D
AIThe SynGAP1 missense variant R3S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta results are not available for this variant. Overall, the majority of evidence points to a benign effect. The prediction is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.538167Disordered0.550331Binding0.3580.9200.875-2.296Likely Benign0.310Likely BenignLikely Benign0.111Likely Benign-0.53Neutral0.115Benign0.013Benign4.02Benign0.00Affected4.3210.31480.4732-103.7-69.11
c.9G>T
R3S
2D
AIThe SynGAP1 missense variant R3S is reported in gnomAD (ID 6‑33420273‑G‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus itself is benign; Foldetta results are not available. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods points to a benign effect. This conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.538167Disordered0.550331Binding0.3580.9200.8756-33420273-G-T16.50e-7-2.296Likely Benign0.310Likely BenignLikely Benign0.111Likely Benign-0.53Neutral0.115Benign0.013Benign4.02Benign0.00Affected4.3210.31480.4732-103.7-69.11
c.1162G>A
G388S
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant G388S is catalogued in gnomAD (ID 6‑33438067‑G‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that converge on a pathogenic interpretation are FoldX, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. The high‑accuracy AlphaMissense‑Optimized score is benign, while the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. In contrast, the protein‑folding stability predictor Foldetta, which integrates FoldX‑MD and Rosetta outputs, indicates a pathogenic effect. No prediction is available from Rosetta alone, and the SGM‑Consensus result aligns with the benign consensus. Overall, the majority of evidence points to a benign impact, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.736850Disordered0.420316Uncertain0.3190.8270.7506-33438067-G-A16.21e-7-5.036Likely Benign0.089Likely BenignLikely Benign3.42Destabilizing3.51.69Ambiguous2.56Destabilizing0.18Likely Benign0.446Likely Benign-0.52Neutral0.980Probably Damaging0.968Probably Damaging1.33Pathogenic0.05Affected4.3230.29010.498501-0.430.03
c.128G>C
G43A
2D
AIThe SynGAP1 missense variant G43A is reported in gnomAD (variant ID 6-33423537‑G‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus itself is likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign effect for G43A, and this conclusion does not contradict any ClinVar status, as none is currently assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.308712Structured0.431462Uncertain0.3960.7620.3756-33423537-G-C21.24e-6-3.925Likely Benign0.073Likely BenignLikely Benign0.026Likely Benign-0.52Neutral0.001Benign0.005Benign4.29Benign0.00Affected4.3210.36770.3450012.214.03
c.1858T>G
S620A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S620A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as likely benign. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as uncertain. No evidence from these analyses suggests a deleterious effect. Consequently, the variant is most likely benign based on the aggregate predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.139895Structured0.100377Uncertain0.9360.2190.000-4.637Likely Benign0.088Likely BenignLikely Benign-0.42Likely Benign0.0-0.90Ambiguous-0.66Ambiguous-0.19Likely Benign0.375Likely Benign-0.52Neutral0.968Probably Damaging0.994Probably Damaging-1.27Pathogenic0.66Tolerated0.49500.3636112.6-16.00
c.2186A>C
N729T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant N729T is not reported in ClinVar (ClinVar status: not listed) but is present in gnomAD (gnomAD ID 6‑33441651‑A‑C). Consensus among the majority of in‑silico predictors is benign: REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates “Likely Benign”; Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, yields an uncertain result. Overall, the evidence strongly supports a benign effect, and this conclusion does not contradict ClinVar status, which has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.750527Disordered0.426547Uncertain0.6510.5830.6256-33441651-A-C16.20e-7-1.952Likely Benign0.103Likely BenignLikely Benign0.52Ambiguous0.31.73Ambiguous1.13Ambiguous-0.34Likely Benign0.052Likely Benign-0.52Neutral0.123Benign0.042Benign3.33Benign1.00Tolerated3.5970.12010.4805002.8-13.00
c.2239G>C
V747L
2D
AIThe SynGAP1 missense variant V747L (ClinVar ID 1985039.0) is listed as ClinVar status Uncertain and is present in gnomAD (6‑33441704‑G‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta stability analysis is unavailable. Overall, the majority of computational evidence supports a benign classification, which is consistent with the ClinVar Uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.594069Binding0.3430.8730.750Uncertain 16-33441704-G-C21.24e-6-2.790Likely Benign0.096Likely BenignLikely Benign0.047Likely Benign-0.52Neutral0.065Benign0.033Benign2.67Benign0.00Affected4.3220.06990.367421-0.414.03
c.2239G>T
V747L
2D
AIThe SynGAP1 missense variant V747L is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Only SIFT predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.594069Binding0.3430.8730.750-2.790Likely Benign0.096Likely BenignLikely Benign0.046Likely Benign-0.52Neutral0.065Benign0.033Benign2.67Benign0.00Affected4.3220.06990.367421-0.414.03
c.2261A>G
E754G
2D
AIThe SynGAP1 missense variant E754G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.505461Disordered0.750531Binding0.3570.8720.500-5.029Likely Benign0.313Likely BenignLikely Benign0.080Likely Benign-0.52Neutral0.801Possibly Damaging0.339Benign2.94Benign0.13Tolerated0.26310.58200-23.1-72.06
c.2383C>G
P795A
2D
AIThe SynGAP1 missense variant P795A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; no tool predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly suggests that P795A is most likely benign, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.972450Disordered0.410339Uncertain0.4570.9030.875-5.348Likely Benign0.049Likely BenignLikely Benign0.053Likely Benign-0.52Neutral0.016Benign0.011Benign4.32Benign0.16Tolerated0.36720.53711-13.4-26.04
c.2545G>C
D849H
2D
AIThe SynGAP1 missense variant D849H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.712013Disordered0.554191Binding0.3190.8130.500-4.624Likely Benign0.345AmbiguousLikely Benign0.149Likely Benign-0.52Neutral0.918Possibly Damaging0.697Possibly Damaging4.14Benign0.00Affected0.19770.86731-10.322.05
c.3325C>G
L1109V
2D
AIThe SynGAP1 missense variant L1109V is catalogued in gnomAD (ID 6‑33443877‑C‑G) but has no ClinVar entry. Across a broad panel of in silico predictors, every tool reports a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool in the set predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a Likely Benign verdict. Foldetta results are not available for this variant. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar status, as none is reported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.856457Disordered0.948334Binding0.3430.8930.8756-33443877-C-G-5.490Likely Benign0.062Likely BenignLikely Benign0.091Likely Benign-0.52Neutral0.001Benign0.005Benign2.72Benign0.19Tolerated4.3220.16760.4353120.4-14.03
c.3326T>C
L1109P
2D
AIThe SynGAP1 missense variant L1109P is listed in ClinVar with an uncertain significance (ClinVar ID 1730257.0) and is not reported in gnomAD. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized indicates a benign effect, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability predictor combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence overwhelmingly supports a benign classification, which does not contradict the ClinVar uncertain status. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.856457Disordered0.948334Binding0.3430.8930.875Conflicting 2-5.313Likely Benign0.120Likely BenignLikely Benign0.151Likely Benign-0.52Neutral0.002Benign0.003Benign2.65Benign0.07Tolerated4.3220.31590.2330-3-3-5.4-16.04
c.3365G>C
G1122A
2D
AIThe SynGAP1 missense variant G1122A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly supports a benign classification, and there is no conflict with ClinVar status, which simply lacks an entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.896620Disordered0.814918Binding0.3570.9320.875-6.692Likely Benign0.076Likely BenignLikely Benign0.168Likely Benign-0.52Neutral0.001Benign0.002Benign4.52Benign0.62Tolerated0.34870.4944102.214.03
c.362C>G
A121G
2D
AIThe SynGAP1 missense variant A121G is catalogued in gnomAD (ID 6‑33432227‑C‑G) but has no ClinVar entry. Across the spectrum of in‑silico predictors, every tool examined—REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—consistently classifies the substitution as benign. No pathogenic predictions are reported. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status remains unavailable. Overall, the evidence strongly supports a benign effect for A121G, and this conclusion does not contradict any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.779859Disordered0.661304Binding0.3620.8880.7506-33432227-C-G42.48e-6-3.123Likely Benign0.099Likely BenignLikely Benign0.073Likely Benign-0.52Neutral0.118Benign0.026Benign4.06Benign0.07Tolerated3.6150.24070.527101-2.2-14.03
c.3853C>G
P1285A
2D
AIThe SynGAP1 missense variant P1285A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.821643Binding0.5570.7590.750-3.902Likely Benign0.060Likely BenignLikely Benign0.052Likely Benign-0.52Neutral0.264Benign0.070Benign4.27Benign0.71Tolerated0.29440.29741-13.4-26.04
c.3932T>C
L1311P
2D
AIThe SynGAP1 missense variant L1311P is listed in ClinVar (ID 833866.0) as Benign and is present in gnomAD (variant ID 6‑33451806‑T‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a Likely Benign classification, and AlphaMissense‑Optimized also reports Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, is not available for this variant. Overall, the majority of computational evidence supports a benign effect, which is consistent with the ClinVar benign annotation and does not contradict the database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.968153Binding0.3930.9070.750Likely Benign 16-33451806-T-C16.21e-7-1.831Likely Benign0.079Likely BenignLikely Benign0.123Likely Benign-0.52Neutral0.579Possibly Damaging0.335Benign2.72Benign0.18Tolerated3.7750.31810.1794-3-3-5.4-16.04
c.3938C>G
P1313R
2D
AIThe SynGAP1 missense variant P1313R is not reported in ClinVar and has no entry in gnomAD. Prediction tools that assess pathogenicity are unanimous: all listed algorithms (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized) predict a benign effect, while none predict pathogenicity. High‑accuracy methods reinforce this consensus: AlphaMissense‑Optimized scores the variant as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates “Likely Benign,” and the protein‑folding stability tool Foldetta provides no result, so it does not influence the assessment. Based on the collective predictions, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.970301Binding0.4520.9020.750-4.634Likely Benign0.161Likely BenignLikely Benign0.088Likely Benign-0.52Neutral0.324Benign0.172Benign4.25Benign0.22Tolerated0.16590.47420-2-2.959.07
c.3965C>T
A1322V
2D
AIThe SynGAP1 missense variant A1322V is catalogued in gnomAD (ID 6‑33451839‑C‑T) but has no ClinVar entry. Across a broad panel of in silico predictors, every tool reports a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool in the set predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized returns a benign prediction, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta results are not available for this variant. Taken together, the computational evidence overwhelmingly supports a benign effect, and this conclusion does not conflict with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.921040Binding0.4660.8250.8756-33451839-C-T-5.376Likely Benign0.076Likely BenignLikely Benign0.076Likely Benign-0.52Neutral0.001Benign0.001Benign4.17Benign0.15Tolerated3.7750.15070.6747002.428.05
c.3967C>T
P1323S
2D
AIThe SynGAP1 missense variant P1323S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.901269Disordered0.907659Binding0.4890.8140.875-6.007Likely Benign0.072Likely BenignLikely Benign0.077Likely Benign-0.52Neutral0.588Possibly Damaging0.122Benign3.88Benign0.00Affected0.37580.43711-10.8-10.04
c.166C>A
L56M
2D
AIThe SynGAP1 missense variant L56M is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. Two tools, ESM1b and AlphaMissense‑Default, return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because it contains two benign and two uncertain calls, and Foldetta data are unavailable. Overall, the balance of evidence (four benign versus three pathogenic predictions, with two uncertain) suggests the variant is most likely benign. This conclusion does not contradict ClinVar status, as the variant has not been reported there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.342579Structured0.476218Uncertain0.4950.6570.000-7.470In-Between0.345AmbiguousLikely Benign0.109Likely Benign-0.51Neutral0.824Possibly Damaging0.910Probably Damaging3.86Benign0.00Affected0.07970.357442-1.918.03
c.191T>C
I64T
2D
AIThe SynGAP1 missense variant I64T is not reported in ClinVar (ClinVar ID None) but is present in gnomAD (ID 6‑33425799‑T‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Those that predict a pathogenic effect are SIFT and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, SGM‑Consensus as Likely Benign, and the Foldetta protein‑folding stability analysis is unavailable. Based on the collective predictions, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.422041Structured0.475481Uncertain0.4780.7470.1256-33425799-T-C16.20e-7-3.183Likely Benign0.943Likely PathogenicAmbiguous0.075Likely Benign-0.51Neutral0.092Benign0.007Benign4.08Benign0.00Affected4.3210.09780.0851-10-5.2-12.05
c.2189T>G
I730S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I730S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar; AlphaMissense‑Default remains uncertain. High‑accuracy assessments—AlphaMissense‑Optimized, the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), and Foldetta (combining FoldX‑MD and Rosetta outputs)—all uniformly predict a benign impact. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.420109Uncertain0.5910.6190.750-6.220Likely Benign0.349AmbiguousLikely Benign0.25Likely Benign0.2-0.12Likely Benign0.07Likely Benign0.47Likely Benign0.123Likely Benign-0.51Neutral1.000Probably Damaging0.967Probably Damaging3.60Benign0.34Tolerated0.26460.0903-1-2-5.3-26.08
c.2225G>C
R742P
2D
AIThe SynGAP1 missense variant R742P is catalogued in gnomAD (6-33441690‑G‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all indicate a benign or likely benign outcome. Only SIFT classifies the change as pathogenic, representing the sole discordant prediction. High‑accuracy assessments further support benignity: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise reports likely benign. The Foldetta protein‑folding stability analysis is not available for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.871313Disordered0.509587Binding0.3090.8560.8756-33441690-G-C16.20e-7-2.920Likely Benign0.112Likely BenignLikely Benign0.081Likely Benign-0.51Neutral0.001Benign0.004Benign2.84Benign0.03Affected4.3220.25980.3637-202.9-59.07
c.241C>G
L81V
2D
AIThe SynGAP1 missense variant L81V is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign status. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence supports a benign classification for L81V, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.632174Disordered0.502033Binding0.2910.8780.250-5.207Likely Benign0.289Likely BenignLikely Benign0.038Likely Benign-0.51Neutral0.178Benign0.014Benign4.04Benign0.00Affected0.14230.2653210.4-14.03
c.2509G>A
V837I
2D
AIThe SynGAP1 missense variant V837I is reported in ClinVar as “Not submitted” and is present in gnomAD (variant ID 6-33443061‑G‑A). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict it to be pathogenic. When predictions are grouped by consensus, the benign group contains seven tools, while the pathogenic group contains two. High‑accuracy assessments reinforce the benign view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is also likely benign. Foldetta results are unavailable. Overall, the majority of evidence indicates that V837I is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.525368Disordered0.626284Binding0.3180.8710.1256-33443061-G-A16.19e-7-4.299Likely Benign0.119Likely BenignLikely Benign0.119Likely Benign-0.51Neutral0.992Probably Damaging0.989Probably Damaging2.63Benign0.13Tolerated3.7750.08330.3848340.314.03
c.2510T>A
V837D
2D
AIThe SynGAP1 missense variant V837D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign (three benign votes versus one pathogenic). High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, SGM‑Consensus as Likely Benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.525368Disordered0.626284Binding0.3180.8710.125-5.712Likely Benign0.785Likely PathogenicAmbiguous0.127Likely Benign-0.51Neutral0.999Probably Damaging0.998Probably Damaging2.61Benign0.85Tolerated0.14150.0902-2-3-7.715.96
c.2611C>G
H871D
2D
AIThe SynGAP1 missense variant H871D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.679301Binding0.2790.8580.250-3.263Likely Benign0.257Likely BenignLikely Benign0.245Likely Benign-0.51Neutral0.016Benign0.026Benign2.80Benign0.31Tolerated0.22710.16171-1-0.3-22.05
c.2648T>A
L883Q
2D
AIThe SynGAP1 missense variant L883Q is reported in gnomAD (6‑33443200‑T‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. The variant is therefore most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.716283Disordered0.641952Binding0.3340.8860.2506-33443200-T-A31.86e-6-3.559Likely Benign0.123Likely BenignLikely Benign0.129Likely Benign-0.51Neutral0.934Possibly Damaging0.637Possibly Damaging2.66Benign0.11Tolerated4.3240.11190.1505-2-2-7.314.97
c.2837G>A
G946E
2D
AIThe SynGAP1 missense variant G946E is listed in ClinVar (ID 1299783.0) as benign and is present in gnomAD (6‑33443389‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized, while polyPhen‑2 HumDiv, SIFT, and ESM1b predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, aligning with the ClinVar designation and showing no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985417Disordered0.845792Binding0.3570.9200.750Benign 36-33443389-G-A138.05e-6-8.793Likely Pathogenic0.257Likely BenignLikely Benign0.341Likely Benign-0.51Neutral0.818Possibly Damaging0.355Benign4.58Benign0.00Affected4.3240.16910.48590-2-3.172.06
c.2853T>A
H951Q
2D
AIThe SynGAP1 missense variant H951Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-4.755Likely Benign0.089Likely BenignLikely Benign0.172Likely Benign-0.51Neutral0.001Benign0.002Benign5.43Benign0.29Tolerated0.27570.332830-0.3-9.01
c.2853T>G
H951Q
2D
AIThe SynGAP1 missense variant H951Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-4.755Likely Benign0.089Likely BenignLikely Benign0.171Likely Benign-0.51Neutral0.001Benign0.002Benign5.43Benign0.29Tolerated0.27570.332830-0.3-9.01
c.2911C>G
P971A
2D
AIThe SynGAP1 missense variant P971A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.951523Binding0.5450.9050.625-4.244Likely Benign0.049Likely BenignLikely Benign0.060Likely Benign-0.51Neutral0.000Benign0.002Benign4.05Benign0.00Affected0.31000.52821-13.4-26.04
c.2911C>T
P971S
2D
AIThe SynGAP1 missense variant P971S is catalogued in gnomAD (ID 6‑33443463‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) all indicate a benign or likely benign outcome. Only SIFT classifies the change as pathogenic, representing a minority opinion. High‑accuracy assessments further support benignity: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise reports likely benign. No Foldetta stability analysis is available, so it does not influence the overall assessment. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.951523Binding0.5450.9050.6256-33443463-C-T16.20e-7-4.188Likely Benign0.061Likely BenignLikely Benign0.058Likely Benign-0.51Neutral0.002Benign0.003Benign3.99Benign0.00Affected4.3220.30090.5667-110.8-10.04
c.293A>T
H98L
2D
AIThe SynGAP1 H98L missense variant is reported in gnomAD (ID 6‑33425901‑A‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts benign, SGM‑Consensus is likely benign, and Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for H98L, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.631713Binding0.3480.8720.6256-33425901-A-T16.32e-7-1.804Likely Benign0.113Likely BenignLikely Benign0.194Likely Benign-0.51Neutral0.115Benign0.012Benign4.24Benign0.00Affected4.3210.11250.6291-3-27.0-23.98
c.2968T>G
S990A
2D
AIThe SynGAP1 missense variant S990A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. Foldetta results are unavailable. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.902387Binding0.3010.9190.750-3.554Likely Benign0.063Likely BenignLikely Benign0.020Likely Benign-0.51Neutral0.001Benign0.004Benign2.91Benign0.03Affected0.45370.4509112.6-16.00
c.3337G>A
G1113S
2D
AIThe SynGAP1 missense variant G1113S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. The variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.905695Disordered0.900456Binding0.3270.9100.875-3.601Likely Benign0.077Likely BenignLikely Benign0.061Likely Benign-0.51Neutral0.905Possibly Damaging0.538Possibly Damaging2.58Benign0.35Tolerated0.24990.530910-0.430.03
c.3341G>A
S1114N
2D
AIThe SynGAP1 missense variant S1114N is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool predicts pathogenicity. The high‑accuracy consensus, SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN), also reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly supports a benign classification, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.908098Disordered0.895196Binding0.2950.9080.875-6.089Likely Benign0.106Likely BenignLikely Benign0.047Likely Benign-0.51Neutral0.071Benign0.058Benign2.71Benign0.06Tolerated0.14160.461011-2.727.03
c.3439A>T
T1147S
2D
AIThe SynGAP1 missense variant T1147S is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.831250Disordered0.746520Binding0.3450.8390.875-2.593Likely Benign0.081Likely BenignLikely Benign0.173Likely Benign-0.51Neutral0.126Benign0.096Benign5.48Benign0.08Tolerated0.31290.375711-0.1-14.03
c.3516C>A
H1172Q
2D
AIThe SynGAP1 missense variant H1172Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus confirms Likely Benign, and Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.626927Disordered0.673805Binding0.4650.7580.625-2.169Likely Benign0.414AmbiguousLikely Benign0.227Likely Benign-0.51Neutral0.451Benign0.265Benign5.47Benign0.39Tolerated0.12490.355730-0.3-9.01
c.3516C>G
H1172Q
2D
AIThe SynGAP1 missense variant H1172Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus confirms Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta) has no available result for this variant. Based on the collective predictions, H1172Q is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.626927Disordered0.673805Binding0.4650.7580.625-2.169Likely Benign0.414AmbiguousLikely Benign0.227Likely Benign-0.51Neutral0.451Benign0.265Benign5.47Benign0.39Tolerated0.12490.355730-0.3-9.01
c.3841G>C
A1281P
2D
AIThe SynGAP1 missense variant A1281P is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.823549Disordered0.821556Binding0.4340.7210.875-3.367Likely Benign0.071Likely BenignLikely Benign0.067Likely Benign-0.51Neutral0.149Benign0.043Benign2.64Benign0.14Tolerated0.21100.35221-1-3.426.04
c.3991A>G
I1331V
2D
AIThe SynGAP1 missense variant I1331V is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as “Uncertain,” SGM‑Consensus as “Likely Benign,” and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.921076Disordered0.941705Binding0.3590.7520.875-2.799Likely Benign0.899Likely PathogenicAmbiguous0.138Likely Benign-0.51Neutral0.581Possibly Damaging0.785Possibly Damaging3.59Benign0.00Affected0.10910.307443-0.3-14.03
c.511G>A
A171T
2D
AIThe SynGAP1 missense variant A171T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only SIFT predicts pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the consensus of the majority of tools, including the high‑accuracy methods, points to a benign impact. This prediction does not contradict any ClinVar annotation, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.562014Disordered0.492272Uncertain0.3580.6520.375-2.388Likely Benign0.136Likely BenignLikely Benign0.019Likely Benign-0.51Neutral0.001Benign0.002Benign4.25Benign0.03Affected0.10750.576310-2.530.03
c.616A>G
I206V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I206V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and Rosetta. No tool predicts a pathogenic outcome; the only inconclusive results are from FoldX (uncertain) and Foldetta (uncertain). High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also predicts benign, while Foldetta remains uncertain. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.298791Structured0.405123Uncertain0.8630.3910.125-5.709Likely Benign0.165Likely BenignLikely Benign1.22Ambiguous0.10.24Likely Benign0.73Ambiguous0.40Likely Benign0.051Likely Benign-0.51Neutral0.001Benign0.007Benign4.27Benign0.53Tolerated0.08330.292043-0.3-14.03
c.87G>A
M29I
2D
AIThe SynGAP1 missense variant M29I is catalogued in gnomAD (6-33423496‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign or tolerated outcomes, while the single pathogenic signal comes from SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign likelihood. Foldetta stability analysis is unavailable for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.541878Disordered0.438540Uncertain0.3410.8830.2506-33423496-G-A63.72e-6-2.425Likely Benign0.185Likely BenignLikely Benign0.067Likely Benign-0.51Neutral0.006Benign0.091Benign4.26Benign0.00Affected4.3210.16800.4385122.6-18.03
c.87G>C
M29I
2D
AIThe SynGAP1 missense variant M29I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.541878Disordered0.438540Uncertain0.3410.8830.250-2.425Likely Benign0.185Likely BenignLikely Benign0.067Likely Benign-0.51Neutral0.006Benign0.091Benign4.26Benign0.00Affected4.3210.16800.4385122.6-18.03
c.87G>T
M29I
2D
AIThe SynGAP1 missense variant M29I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this assessment does not contradict any ClinVar annotation (none is present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.541878Disordered0.438540Uncertain0.3410.8830.250-2.425Likely Benign0.185Likely BenignLikely Benign0.067Likely Benign-0.51Neutral0.006Benign0.091Benign4.26Benign0.00Affected4.3210.16800.4385122.6-18.03
c.101A>T
Y34F
2D
AIThe SynGAP1 missense variant Y34F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; no Foldetta stability result is available. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.529623Disordered0.435847Uncertain0.3030.8550.375-3.275Likely Benign0.127Likely BenignLikely Benign0.094Likely Benign-0.50Neutral0.458Possibly Damaging0.481Possibly Damaging4.20Benign0.00Affected0.26040.3591734.1-16.00
c.1100T>C
L367P
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L367P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Functional prediction tools that agree on benign impact include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Tools that predict pathogenicity are FoldX, Rosetta, Foldetta, polyPhen‑2 HumDiv, SIFT, and FATHMM; premPS remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as likely benign, while Foldetta (combining FoldX‑MD and Rosetta outputs) predicts a pathogenic effect. Overall, the majority of predictions lean toward a benign effect, and this conclusion does not contradict any ClinVar annotation because no ClinVar status exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.370445Structured0.441805Uncertain0.7900.6570.250-2.418Likely Benign0.160Likely BenignLikely Benign2.13Destabilizing0.44.05Destabilizing3.09Destabilizing0.72Ambiguous0.212Likely Benign-0.50Neutral0.627Possibly Damaging0.196Benign1.72Pathogenic0.02Affected0.39460.1874-3-3-5.4-16.04
c.1135T>A
S379T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S379T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, polyPhen‑2 HumVar, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are Rosetta, polyPhen‑2 HumDiv, and the Foldetta stability method. FoldX is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as likely benign, and Foldetta as pathogenic. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.728858Disordered0.433206Uncertain0.3270.9310.625-5.646Likely Benign0.092Likely BenignLikely Benign1.42Ambiguous0.63.96Destabilizing2.69Destabilizing0.06Likely Benign0.230Likely Benign-0.50Neutral0.462Possibly Damaging0.084Benign3.87Benign0.16Tolerated0.22930.6248110.114.03
c.1135T>G
S379A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S379A is reported in gnomAD (variant ID 6‑33438040‑T‑G) but has no entry in ClinVar. All available in‑silico predictors classify the change as benign: REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the consensus SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). No tool predicts pathogenicity. High‑accuracy assessments are consistent: AlphaMissense‑Optimized predicts benign; the SGM‑Consensus (majority vote) indicates “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta outputs, also predicts benign. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.728858Disordered0.433206Uncertain0.3270.9310.6256-33438040-T-G-4.300Likely Benign0.077Likely BenignLikely Benign-0.22Likely Benign0.31.03Ambiguous0.41Likely Benign0.10Likely Benign0.217Likely Benign-0.50Neutral0.012Benign0.002Benign3.91Benign0.21Tolerated4.32110.50320.5555Strenghten112.6-16.00
c.1328G>A
G443D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G443D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only AlphaMissense‑Default predicts a pathogenic outcome. Uncertain results come from Rosetta and Foldetta. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as likely benign, and Foldetta as inconclusive. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation and gnomAD presence, so there is no contradiction with existing clinical data. The variant is most likely benign based on the current predictive landscape.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.250310Structured0.258623Uncertain0.9350.2060.000-6.818Likely Benign0.761Likely PathogenicLikely Benign-0.19Likely Benign0.2-1.72Ambiguous-0.96Ambiguous0.32Likely Benign0.072Likely Benign-0.50Neutral0.345Benign0.072Benign3.63Benign0.43Tolerated0.16870.20901-1-3.158.04
c.2656G>T
A886S
2D
AIThe SynGAP1 missense variant A886S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.716283Disordered0.619166Binding0.3590.9220.500-2.366Likely Benign0.081Likely BenignLikely Benign0.055Likely Benign-0.50Neutral0.224Benign0.185Benign2.24Pathogenic0.00Affected0.27550.563911-2.616.00
c.2716C>A
L906I
2D
AIThe SynGAP1 missense variant L906I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; no Foldetta stability result is available. Overall, the majority of evidence points to a benign impact for this variant. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.604312Disordered0.644316Binding0.3150.9200.250-5.882Likely Benign0.174Likely BenignLikely Benign0.036Likely Benign-0.50Neutral0.905Possibly Damaging0.545Possibly Damaging2.45Pathogenic0.32Tolerated0.10600.4093220.70.00
c.2806G>A
A936T
2D
AIThe SynGAP1 missense variant A936T is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443358‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; no tool predicts pathogenicity. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the computational evidence overwhelmingly indicates that the variant is most likely benign, which does not contradict the ClinVar status of uncertainty.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.973218Binding0.3190.8740.625Uncertain 16-33443358-G-A16.20e-7-4.540Likely Benign0.091Likely BenignLikely Benign0.047Likely Benign-0.50Neutral0.051Benign0.033Benign2.67Benign0.09Tolerated3.7750.16930.700301-2.530.03
c.2861C>A
P954H
2D
AIThe SynGAP1 missense variant P954H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar or gnomAD entries—there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984159Disordered0.932268Binding0.4650.9260.750-3.670Likely Benign0.082Likely BenignLikely Benign0.098Likely Benign-0.50Neutral0.041Benign0.067Benign2.75Benign0.04Affected0.20540.47560-2-1.640.02
c.2893C>A
H965N
2D
AIThe SynGAP1 missense variant H965N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Across the available in‑silico predictors, the majority (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized) uniformly predict a benign effect, while no tool predicts pathogenicity. ESM1b is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.978700Binding0.3420.8820.750-7.605In-Between0.082Likely BenignLikely Benign0.076Likely Benign-0.50Neutral0.000Benign0.001Benign4.09Benign0.80Tolerated0.23600.383821-0.3-23.04
c.2927T>A
F976Y
2D
AIThe SynGAP1 missense variant F976Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. The variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.975061Binding0.3110.8940.625-3.902Likely Benign0.225Likely BenignLikely Benign0.172Likely Benign-0.50Neutral0.925Possibly Damaging0.529Possibly Damaging4.11Benign0.80Tolerated0.19420.225773-4.116.00
c.2974G>C
V992L
2D
AIThe SynGAP1 missense variant V992L is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the evidence strongly supports a benign classification, and this conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.921728Binding0.3310.9170.750-2.333Likely Benign0.086Likely BenignLikely Benign0.060Likely Benign-0.50Neutral0.086Benign0.038Benign4.24Benign0.16Tolerated0.12110.520221-0.414.03
c.299A>T
Y100F
2D
AIThe SynGAP1 missense variant Y100F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.699094Disordered0.675421Binding0.3410.8800.625-3.056Likely Benign0.117Likely BenignLikely Benign0.139Likely Benign-0.50Neutral0.928Possibly Damaging0.222Benign4.21Benign0.00Affected0.27840.3087734.1-16.00
c.3139T>G
S1047A
2D
AIThe SynGAP1 missense variant S1047A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable. Overall, the consensus of all available predictions indicates that the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.963420Disordered0.933764Binding0.4090.9090.750-3.503Likely Benign0.060Likely BenignLikely Benign0.040Likely Benign-0.50Neutral0.001Benign0.002Benign2.65Benign0.07Tolerated0.44600.5548112.6-16.00
c.3247A>C
K1083Q
2D
AIThe SynGAP1 missense variant K1083Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions come from polyPhen‑2 HumDiv and HumVar. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign effect. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from both general and high‑accuracy tools points to a benign impact for K1083Q, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.837511Disordered0.978906Binding0.3020.8931.000-2.214Likely Benign0.390AmbiguousLikely Benign0.099Likely Benign-0.50Neutral0.999Probably Damaging0.995Probably Damaging4.06Benign0.37Tolerated0.48210.1647110.4-0.04
c.3295T>C
Y1099H
2D
AIThe SynGAP1 missense variant Y1099H is reported in gnomAD (variant ID 6-33443847‑T‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict it to be pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority‑vote) is likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.885302Disordered0.974267Binding0.4000.8621.0006-33443847-T-C16.49e-7-3.620Likely Benign0.267Likely BenignLikely Benign0.123Likely Benign-0.50Neutral0.990Probably Damaging0.796Possibly Damaging2.76Benign0.18Tolerated3.7750.24530.073520-1.9-26.03
c.3803T>A
L1268Q
2D
AIThe SynGAP1 missense variant L1268Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two PolyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus also indicates benign. Foldetta results are not available, so they do not influence the assessment. Overall, the preponderance of evidence points to a benign impact for this variant, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.458154Structured0.804315Binding0.8590.6290.000-5.707Likely Benign0.143Likely BenignLikely Benign0.062Likely Benign-0.50Neutral0.990Probably Damaging0.637Possibly Damaging2.68Benign0.08Tolerated0.09880.0558-2-2-7.314.97
c.457A>T
T153S
2D
AIThe SynGAP1 missense variant T153S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.501700Disordered0.502105Binding0.2970.8180.625-1.890Likely Benign0.118Likely BenignLikely Benign0.118Likely Benign-0.50Neutral0.235Benign0.039Benign4.19Benign0.14Tolerated0.37560.288611-0.1-14.03
c.458C>G
T153S
2D
AIThe SynGAP1 missense variant T153S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.501700Disordered0.502105Binding0.2970.8180.625-1.890Likely Benign0.118Likely BenignLikely Benign0.066Likely Benign-0.50Neutral0.235Benign0.039Benign4.19Benign0.14Tolerated0.37560.288611-0.1-14.03
c.53A>C
Y18S
2D
AIThe SynGAP1 missense variant Y18S is reported in gnomAD (ID 6‑33420317‑A‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods points to a benign impact for Y18S. This conclusion is consistent with the absence of a pathogenic ClinVar classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.483068Structured0.446314Uncertain0.3450.9080.3756-33420317-A-C-1.061Likely Benign0.280Likely BenignLikely Benign0.124Likely Benign-0.50Neutral0.389Benign0.036Benign4.09Benign0.00Affected4.3210.49610.2640-2-30.5-76.10
c.58C>A
P20T
2D
AIThe SynGAP1 missense variant P20T is reported in gnomAD (ID 6‑33420322‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT each predict pathogenic. High‑accuracy assessments reinforce the benign view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign. No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the preponderance of evidence, including the high‑accuracy tools, points to the variant being most likely benign, and this conclusion is not contradicted by any ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.529623Disordered0.442804Uncertain0.4480.8990.5006-33420322-C-A-3.258Likely Benign0.223Likely BenignLikely Benign0.065Likely Benign-0.50Neutral0.909Possibly Damaging0.641Possibly Damaging4.28Benign0.00Affected4.3210.17810.6640-100.93.99
c.682A>T
T228S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 T228S missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Foldetta, premPS, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while Rosetta and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction, and Foldetta (combining FoldX‑MD and Rosetta outputs) reports a benign stability change. Taken together, the overwhelming majority of evidence indicates a benign impact for T228S. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.104810Structured0.321733Uncertain0.8290.3160.125-2.028Likely Benign0.493AmbiguousLikely Benign0.32Likely Benign0.10.63Ambiguous0.48Likely Benign0.05Likely Benign0.458Likely Benign-0.50Neutral0.734Possibly Damaging0.138Benign5.65Benign1.00Tolerated0.33950.510711-0.1-14.03
c.2111G>A
S704N
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S704N is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33441370‑G‑A). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while premPS and AlphaMissense‑Default are inconclusive. High‑accuracy assessments reinforce the benign interpretation: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is “Likely Benign”; and Foldetta (combining FoldX‑MD and Rosetta outputs) is benign. Overall, the majority of evidence points to a benign effect, which does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.096677Structured0.383620Uncertain0.9280.3630.000Conflicting 46-33441370-G-A271.67e-5-5.917Likely Benign0.421AmbiguousLikely Benign0.48Likely Benign0.1-0.12Likely Benign0.18Likely Benign0.54Ambiguous0.058Likely Benign-0.49Neutral0.771Possibly Damaging0.275Benign3.39Benign0.08Tolerated3.47100.09110.375411-2.727.03233.2-29.1-0.10.0-0.10.1XPotentially BenignSer704 is located at the end and outer surface of an α-helix (res. Thr704-Gly712), which is connected via a tight turn or loop to another α-helix (res. Asp684-Gln702). The hydroxyl side chain of Ser704 occasionally forms a hydrogen bond with the amide group of Ala707. However, in the variant simulations, the carboxamide side chain of Asn704 achieves more lasting and numerous hydrogen-bonding interactions with the residues at the helix end, such as Glu706, Ala707, and Leu708. Consequently, the residue swap could strengthen the α-helix secondary structure integrity at the helix end, which could have either positive or negative effects on its function.
c.2217G>C
E739D
2D
AIThe SynGAP1 missense variant E739D is listed in ClinVar (ID 3661302.0) with an “Uncertain” status and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this is not in conflict with the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.456400Uncertain0.3130.8340.875Uncertain 1-3.369Likely Benign0.062Likely BenignLikely Benign0.097Likely Benign-0.49Neutral0.002Benign0.005Benign2.59Benign0.00Affected0.21450.4732320.0-14.03
c.2217G>T
E739D
2D
AIIn silico analysis of the SynGAP1 E739D variant shows a consensus toward benign impact. Benign predictions come from SGM‑Consensus, REVEL, PROVEAN, polyPhen2_HumDiv, polyPhen2_HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized, whereas only SIFT predicts pathogenicity. High‑accuracy tools AlphaMissense‑Optimized and the SGM Consensus both classify the variant as benign; Foldetta results are unavailable. ClinVar has no entry for this variant and it is not present in gnomAD, so there is no conflicting evidence. Thus, the variant is most likely benign, and this assessment does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.456400Uncertain0.3130.8340.875-3.369Likely Benign0.062Likely BenignLikely Benign0.097Likely Benign-0.49Neutral0.002Benign0.005Benign2.59Benign0.00Affected0.21450.4732320.0-14.03
c.2396C>G
P799R
2D
AIThe SynGAP1 missense variant P799R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a “Likely Benign” outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) likewise indicates benign. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the preponderance of evidence points to the variant being most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.871313Disordered0.537892Binding0.4000.8940.750-5.100Likely Benign0.141Likely BenignLikely Benign0.029Likely Benign-0.49Neutral0.029Benign0.022Benign4.27Benign0.00Affected0.14250.29050-2-2.959.07
c.2482A>T
T828S
2D
AIThe SynGAP1 missense variant T828S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). In contrast, the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is also likely benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence indicates that T828S is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.604312Disordered0.631236Binding0.3210.8790.500-2.851Likely Benign0.285Likely BenignLikely Benign0.152Likely Benign-0.49Neutral0.999Probably Damaging0.992Probably Damaging2.67Benign0.52Tolerated0.33320.391311-0.1-14.03
c.2642T>C
L881S
2D
AIThe SynGAP1 missense variant L881S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for the L881S variant, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.629350Binding0.2990.8740.250-3.063Likely Benign0.169Likely BenignLikely Benign0.051Likely Benign-0.49Neutral0.068Benign0.012Benign2.49Pathogenic0.00Affected0.33630.0850-3-2-4.6-26.08
c.2698A>G
T900A
2D
AIThe SynGAP1 missense variant T900A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.465347Uncertain0.2890.9240.375-2.289Likely Benign0.081Likely BenignLikely Benign0.028Likely Benign-0.49Neutral0.059Benign0.061Benign2.73Benign0.40Tolerated0.40180.4059102.5-30.03
c.2883C>A
H961Q
2D
AIThe SynGAP1 missense variant H961Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only SIFT and ESM1b predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict (3 benign vs. 1 pathogenic). High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750-8.368Likely Pathogenic0.118Likely BenignLikely Benign0.088Likely Benign-0.49Neutral0.255Benign0.105Benign4.17Benign0.02Affected0.20220.374330-0.3-9.01
c.2883C>G
H961Q
2D
AIThe SynGAP1 missense variant H961Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT and ESM1b predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a majority‑benign vote and is reported as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the available predictions indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750-8.368Likely Pathogenic0.118Likely BenignLikely Benign0.088Likely Benign-0.49Neutral0.255Benign0.105Benign4.17Benign0.02Affected0.20220.374330-0.3-9.01
c.291G>C
E97D
2D
AIThe SynGAP1 missense variant E97D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the overall assessment. Overall, the majority of evidence points to the variant being most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.609018Binding0.3400.8670.625-3.239Likely Benign0.077Likely BenignLikely Benign0.081Likely Benign-0.49Neutral0.880Possibly Damaging0.636Possibly Damaging4.12Benign0.00Affected4.3210.19870.5559320.0-14.03
c.291G>T
E97D
2D
AIThe SynGAP1 missense variant E97D is listed in ClinVar (ID 1313570.0) with an “Uncertain” clinical significance and is present in gnomAD (variant ID 6‑33425899‑G‑T). Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Pathogenic predictions come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect. This consensus does not contradict the ClinVar “Uncertain” status, which remains unresolved.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.609018Binding0.3400.8670.625Uncertain 36-33425899-G-T-3.239Likely Benign0.077Likely BenignLikely Benign0.081Likely Benign-0.49Neutral0.880Possibly Damaging0.636Possibly Damaging4.12Benign0.00Affected4.3210.19870.5559320.0-14.03
c.301C>A
H101N
2D
AIThe SynGAP1 missense variant H101N is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is a majority vote of the benign‑predicted tools). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM‑Consensus (derived from the same set of benign‑predicted tools) also indicates a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.791621Disordered0.688356Binding0.3700.8840.625-3.598Likely Benign0.072Likely BenignLikely Benign0.104Likely Benign-0.49Neutral0.659Possibly Damaging0.775Possibly Damaging4.20Benign0.00Affected0.16510.299421-0.3-23.04
c.301C>G
H101D
2D
AIThe SynGAP1 missense variant H101D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this conclusion is not in conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.791621Disordered0.688356Binding0.3700.8840.625-2.788Likely Benign0.227Likely BenignLikely Benign0.136Likely Benign-0.49Neutral0.824Possibly Damaging0.840Possibly Damaging4.20Benign0.00Affected0.24790.22721-1-0.3-22.05
c.3269A>G
N1090S
2D
AIThe SynGAP1 missense variant N1090S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools, polyPhen‑2 HumDiv and HumVar, predict pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy methods reinforce this view: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.896620Disordered0.979886Binding0.3410.8871.000-2.451Likely Benign0.228Likely BenignLikely Benign0.135Likely Benign-0.49Neutral0.997Probably Damaging0.983Probably Damaging2.97Benign0.38Tolerated0.39800.7620112.7-27.03
c.3365G>A
G1122D
2D
AIThe SynGAP1 missense variant G1122D is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Optimized. Only ESM1b predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also favors benign (2 benign vs. 1 pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that G1122D is most likely benign, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.896620Disordered0.814918Binding0.3570.9320.875-9.991Likely Pathogenic0.430AmbiguousLikely Benign0.332Likely Benign-0.49Neutral0.411Benign0.091Benign4.49Benign0.10Tolerated0.17460.20351-1-3.158.04
c.343C>A
Q115K
2D
AIThe SynGAP1 missense variant Q115K is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign interpretation: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict benign, while the majority of other predictors (polyPhen‑2 HumDiv and HumVar) indicate pathogenic. When predictions are grouped by agreement, the benign‑oriented tools outnumber the pathogenic ones, and the single uncertain call from AlphaMissense‑Default does not alter the overall trend. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized classifies the variant as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports it as Likely Benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Based on the preponderance of benign predictions and the high‑accuracy consensus, the variant is most likely benign; this conclusion is consistent with the absence of a ClinVar pathogenic claim.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.657256Binding0.3270.8780.750-3.365Likely Benign0.507AmbiguousLikely Benign0.101Likely Benign-0.49Neutral0.924Possibly Damaging0.857Possibly Damaging4.18Benign0.40Tolerated0.17040.367811-0.40.04
c.3673T>A
S1225T
2D
AIThe SynGAP1 missense variant S1225T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) reports likely benign; Foldetta results are not available. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.513880Disordered0.441915Uncertain0.8910.5440.500-4.409Likely Benign0.057Likely BenignLikely Benign0.216Likely Benign-0.49Neutral0.003Benign0.008Benign5.50Benign0.60Tolerated0.09720.4618110.114.03
c.3850C>A
L1284M
2D
AIThe SynGAP1 missense variant L1284M is reported in gnomAD (ID 6‑33447898‑C‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from the four benign‑oriented tools). Pathogenic predictions come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar classification (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.824557Binding0.4410.7480.8756-33447898-C-A-5.332Likely Benign0.104Likely BenignLikely Benign0.044Likely Benign-0.49Neutral0.970Probably Damaging0.637Possibly Damaging2.61Benign0.03Affected3.7750.07310.209224-1.918.03
c.3980C>A
P1327H
2D
AIThe SynGAP1 missense variant P1327H is reported in gnomAD (ID 6‑33451854‑C‑A) and has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus is Likely Benign, and Foldetta results are unavailable. Based on the preponderance of evidence from both general and high‑accuracy predictors, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.896620Disordered0.900145Binding0.3690.7770.8756-33451854-C-A-5.496Likely Benign0.263Likely BenignLikely Benign0.144Likely Benign-0.49Neutral0.998Probably Damaging0.953Probably Damaging4.09Benign0.04Affected3.7750.15590.3932-20-1.640.02
c.494G>A
S165N
2D
AIThe SynGAP1 missense variant S165N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and ESM1b. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also resolves to benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, as no ClinVar classification exists for S165N.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.429200Structured0.509123Binding0.3240.6440.250-9.041Likely Pathogenic0.509AmbiguousLikely Benign0.074Likely Benign-0.49Neutral0.532Possibly Damaging0.229Benign4.03Benign0.00Affected0.15890.486211-2.727.03
c.85A>C
M29L
2D
AIThe SynGAP1 missense variant M29L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.541878Disordered0.438540Uncertain0.3410.8830.250-1.633Likely Benign0.079Likely BenignLikely Benign0.200Likely Benign-0.49Neutral0.006Benign0.039Benign4.27Benign0.00Affected0.19840.5336421.9-18.03
c.85A>T
M29L
2D
AIThe SynGAP1 missense variant M29L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect; there is no conflict with ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.541878Disordered0.438540Uncertain0.3410.8830.250-1.633Likely Benign0.079Likely BenignLikely Benign0.200Likely Benign-0.49Neutral0.006Benign0.039Benign4.27Benign0.00Affected0.19840.5336421.9-18.03
c.902C>T
A301V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A301V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: SGM‑Consensus (Likely Benign), REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools, polyPhen‑2 HumDiv and HumVar, predict pathogenicity. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, predicts benign. Thus, the overall evidence supports a benign classification for A301V, and this conclusion is consistent with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.429200Structured0.258424Uncertain0.6470.2720.375-2.476Likely Benign0.095Likely BenignLikely Benign0.25Likely Benign0.10.48Likely Benign0.37Likely Benign0.06Likely Benign0.116Likely Benign-0.49Neutral0.997Probably Damaging0.983Probably Damaging4.14Benign0.26Tolerated0.10960.6264002.428.05
c.1597G>A
A533T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A533T is catalogued in gnomAD (6-33438840‑G‑A) but has no ClinVar entry. In silico predictors overwhelmingly favor a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign or tolerated outcomes, whereas only FATHMM predicts pathogenicity. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, the SGM Consensus is Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta) predicts a benign stability change. Overall, the evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.179055Structured0.026324Uncertain0.8430.3930.0006-33438840-G-A21.24e-6-5.396Likely Benign0.084Likely BenignLikely Benign0.30Likely Benign0.10.31Likely Benign0.31Likely Benign0.19Likely Benign0.147Likely Benign-0.48Neutral0.002Benign0.001Benign-1.26Pathogenic0.11Tolerated3.37350.14130.654101-2.530.03
c.1597G>C
A533P
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A533P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all predict benign. Only FATHMM predicts pathogenic. Stability‑based methods are inconclusive: FoldX, Rosetta, and the combined Foldetta output are listed as uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as likely benign, and Foldetta as unavailable. Overall, the consensus of the majority of tools indicates a benign impact. This prediction does not contradict ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.179055Structured0.026324Uncertain0.8430.3930.000-3.951Likely Benign0.081Likely BenignLikely Benign-0.93Ambiguous0.3-0.92Ambiguous-0.93Ambiguous-0.18Likely Benign0.187Likely Benign-0.48Neutral0.000Benign0.001Benign-1.26Pathogenic0.09Tolerated0.19250.52991-1-3.426.04
c.2347A>C
M783L
2D
AIThe SynGAP1 missense variant M783L is not reported in ClinVar and is absent from gnomAD. In silico prediction tools that assess sequence conservation and structural impact uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the collective evidence strongly supports a benign classification, and this conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.736850Disordered0.738119Binding0.3310.8890.625-1.915Likely Benign0.138Likely BenignLikely Benign0.108Likely Benign-0.48Neutral0.004Benign0.006Benign2.99Benign1.00Tolerated0.17270.4461421.9-18.03
c.2347A>T
M783L
2D
AIThe SynGAP1 missense variant M783L is not reported in ClinVar and is absent from gnomAD. In silico prediction tools that assess sequence conservation and structural impact (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized) all classify the change as benign. No tool in the dataset predicts pathogenicity. High‑accuracy consensus methods reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability approach, has no available result for this variant. Overall, the collective evidence strongly supports a benign interpretation, and this conclusion is consistent with the lack of a ClinVar classification—there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.736850Disordered0.738119Binding0.3310.8890.625-1.915Likely Benign0.138Likely BenignLikely Benign0.110Likely Benign-0.48Neutral0.004Benign0.006Benign2.99Benign1.00Tolerated0.17270.4461421.9-18.03
c.2399G>C
G800A
2D
AIThe SynGAP1 missense variant G800A is listed in gnomAD (6-33442951‑G‑C) but has no ClinVar entry. Across the available in‑silico predictors, every tool reports a benign effect: SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. No tool predicts pathogenicity. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no reported result for this variant. Based on the unanimous benign predictions and the absence of any pathogenic calls, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.852992Disordered0.588350Binding0.3030.8840.6256-33442951-G-C74.34e-6-3.550Likely Benign0.081Likely BenignLikely Benign0.031Likely Benign-0.48Neutral0.011Benign0.006Benign2.78Benign1.00Tolerated4.3220.34660.4850012.214.0310.1016/j.ajhg.2020.11.011
c.2543G>C
G848A
2D
AIThe SynGAP1 missense variant G848A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.563942Binding0.2870.8160.500-3.560Likely Benign0.142Likely BenignLikely Benign0.115Likely Benign-0.48Neutral0.856Possibly Damaging0.554Possibly Damaging2.61Benign0.07Tolerated0.39710.5145102.214.03
c.2689T>G
S897A
2D
AIThe SynGAP1 missense variant S897A is not reported in ClinVar and is absent from gnomAD. All evaluated in‑silico predictors—including REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods likewise support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.699094Disordered0.418474Uncertain0.2920.9280.500-3.959Likely Benign0.122Likely BenignLikely Benign0.060Likely Benign-0.48Neutral0.288Benign0.208Benign2.71Benign0.81Tolerated0.45390.5684112.6-16.00
c.2712G>A
M904I
2D
AIThe SynGAP1 missense variant M904I is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all return benign scores, and AlphaMissense‑Optimized also predicts a benign effect. No tool predicts pathogenicity, and the only uncertain result comes from AlphaMissense‑Default, which is inconclusive. The high‑accuracy consensus methods corroborate this benign assessment: the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign,” and AlphaMissense‑Optimized explicitly labels the variant as benign. Foldetta, a protein‑folding stability predictor, has no available result for this residue. Taken together, the evidence overwhelmingly supports a benign impact for M904I, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation. Thus, the variant is most likely benign, and this conclusion does not contradict the ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.589073Binding0.3500.9200.250-3.845Likely Benign0.385AmbiguousLikely Benign0.023Likely Benign-0.48Neutral0.039Benign0.023Benign2.78Benign0.07Tolerated0.16940.3633212.6-18.03
c.2712G>C
M904I
2D
AIThe SynGAP1 missense variant M904I is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all return benign scores, and AlphaMissense‑Optimized also predicts a benign effect. No tool predicts pathogenicity, and the only uncertain result comes from AlphaMissense‑Default, which is inconclusive. The high‑accuracy consensus methods corroborate this benign assessment: the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign,” and AlphaMissense‑Optimized also indicates a benign outcome. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Taken together, the evidence overwhelmingly supports a benign impact, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.589073Binding0.3500.9200.250-3.845Likely Benign0.385AmbiguousLikely Benign0.023Likely Benign-0.48Neutral0.039Benign0.023Benign2.78Benign0.07Tolerated0.16940.3633212.6-18.03
c.2712G>T
M904I
2D
AIThe SynGAP1 missense variant M904I is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all return benign scores, and AlphaMissense‑Optimized also predicts a benign effect. No tool predicts pathogenicity, and the only uncertain result comes from AlphaMissense‑Default, which is inconclusive. The high‑accuracy consensus methods corroborate this benign assessment: the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign,” and AlphaMissense‑Optimized also indicates a benign outcome. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Taken together, the evidence overwhelmingly supports a benign impact, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.589073Binding0.3500.9200.250-3.845Likely Benign0.385AmbiguousLikely Benign0.023Likely Benign-0.48Neutral0.039Benign0.023Benign2.78Benign0.07Tolerated0.16940.3633212.6-18.03
c.2843G>T
G948V
2D
AIThe SynGAP1 missense variant G948V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods indicates that G948V is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.862121Binding0.3650.9190.750-6.541Likely Benign0.102Likely BenignLikely Benign0.256Likely Benign-0.48Neutral0.901Possibly Damaging0.435Benign4.52Benign0.06Tolerated0.14640.3507-1-34.642.08
c.2903G>A
G968D
2D
AIThe SynGAP1 missense variant G968D is catalogued in gnomAD (ID 6‑33443455‑G‑A) but has no ClinVar entry. Across a broad panel of in‑silico predictors, every tool reports a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity, so the pathogenic‑prediction group is empty. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available for this variant. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.961360Binding0.3270.8960.7506-33443455-G-A16.20e-7-5.134Likely Benign0.179Likely BenignLikely Benign0.157Likely Benign-0.48Neutral0.440Benign0.198Benign4.19Benign0.21Tolerated4.3220.19650.3243-11-3.158.04
c.3190C>G
Q1064E
2D
AIThe SynGAP1 missense variant Q1064E is not reported in ClinVar and is absent from gnomAD. All available in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are not available. Based on the unanimous benign predictions and lack of ClinVar evidence, the variant is most likely benign and does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875-4.277Likely Benign0.184Likely BenignLikely Benign0.075Likely Benign-0.48Neutral0.203Benign0.077Benign4.22Benign0.32Tolerated0.22590.2843220.00.98
c.3334G>C
E1112Q
2D
AIThe SynGAP1 missense variant E1112Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign. The Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the preponderance of evidence from multiple in silico predictors and high‑accuracy tools points to a benign impact for E1112Q, and this conclusion does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.894241Disordered0.909381Binding0.3350.9020.875-1.975Likely Benign0.364AmbiguousLikely Benign0.102Likely Benign-0.48Neutral0.611Possibly Damaging0.305Benign2.71Benign0.42Tolerated0.20310.7430220.0-0.98
c.3511G>A
A1171T
2D
AIThe SynGAP1 missense variant A1171T is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. All available in‑silico predictors classify the change as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a “Likely Benign” outcome. No tool predicts pathogenicity. High‑accuracy assessments confirm the benign prediction: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.599170Disordered0.702689Binding0.4720.7750.500Uncertain 1-3.658Likely Benign0.149Likely BenignLikely Benign0.201Likely Benign-0.48Neutral0.245Benign0.138Benign5.45Benign0.07Tolerated4.3240.14210.546510-2.530.03
c.3554A>G
K1185R
2D
AIThe SynGAP1 missense variant K1185R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign impact for K1185R, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.566480Disordered0.510264Binding0.6420.6380.625-2.898Likely Benign0.224Likely BenignLikely Benign0.130Likely Benign-0.48Neutral0.997Probably Damaging0.989Probably Damaging2.67Benign0.66Tolerated0.44760.090932-0.628.01
c.477C>G
I159M
2D
AIThe SynGAP1 missense variant I159M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical databases.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.454136Structured0.529953Binding0.2780.7310.125-9.838Likely Pathogenic0.142Likely BenignLikely Benign0.071Likely Benign-0.48Neutral0.995Probably Damaging0.986Probably Damaging3.89Benign0.00Affected0.06780.250021-2.618.03
c.4A>G
S2G
2D
AIThe SynGAP1 missense variant S2G is reported in gnomAD (ID 6‑33420268‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign status. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign effect for this variant, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.543646Binding0.3820.9220.7506-33420268-A-G16.58e-7-4.273Likely Benign0.124Likely BenignLikely Benign0.079Likely Benign-0.48Neutral0.012Benign0.002Benign4.10Benign0.00Affected4.3210.28720.5495010.4-30.03
c.1057C>A
L353M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L353M has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, FoldX, PROVEAN, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and FATHMM. Uncertain results come from Rosetta, Foldetta, and premPS. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, SGM‑Consensus as Likely Benign, and Foldetta as Uncertain. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the absence of a ClinVar classification; there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.137348Structured0.373584Uncertain0.9260.3150.000-6.943Likely Benign0.206Likely BenignLikely Benign0.10Likely Benign0.01.28Ambiguous0.69Ambiguous0.60Ambiguous0.117Likely Benign-0.47Neutral0.744Possibly Damaging0.289Benign1.33Pathogenic0.03Affected0.08470.408042-1.918.03
c.1093G>A
V365I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V365I is reported in gnomAD (variant ID 6‑33437998‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate benign or tolerated. Only FATHMM predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus (majority vote) is Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta stability outputs) reports a benign effect. No prediction or folding stability result is missing or inconclusive. Based on the collective evidence, V365I is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.414856Structured0.441505Uncertain0.9230.6080.2506-33437998-G-A42.65e-6-5.943Likely Benign0.155Likely BenignLikely Benign-0.65Ambiguous0.2-0.11Likely Benign-0.38Likely Benign0.13Likely Benign0.036Likely Benign-0.47Neutral0.451Benign0.137Benign1.76Pathogenic0.10Tolerated3.38210.06570.4447340.314.03
c.1118G>C
G373A
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant G373A is not reported in ClinVar and is absent from gnomAD. Functional prediction consensus shows a predominance of benign calls: REVEL, premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) all predict a benign effect. Pathogenic predictions are limited to SIFT and FoldX, while Rosetta and Foldetta yield uncertain results. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and Foldetta remains inconclusive. Overall, the majority of evidence indicates that G373A is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.529623Disordered0.429267Uncertain0.2950.7990.625-5.181Likely Benign0.099Likely BenignLikely Benign2.44Destabilizing0.80.69Ambiguous1.57Ambiguous-0.01Likely Benign0.227Likely Benign-0.47Neutral0.000Benign0.000Benign3.93Benign0.01Affected0.41720.5053102.214.03
c.1120T>A
S374T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S374T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on benign impact include REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is benign, and Foldetta, which integrates FoldX‑MD and Rosetta outputs, is uncertain but does not indicate destabilization. Overall, the evidence strongly favors a benign effect for S374T, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.642678Disordered0.428948Uncertain0.3330.8120.625-5.415Likely Benign0.088Likely BenignLikely Benign0.39Likely Benign0.10.80Ambiguous0.60Ambiguous-0.02Likely Benign0.176Likely Benign-0.47Neutral0.118Benign0.049Benign5.32Benign0.12Tolerated0.22120.6466110.114.03
c.161A>C
N54T
2D
AIThe SynGAP1 missense variant N54T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence points to a benign impact, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.196879Structured0.464669Uncertain0.5040.6590.000-5.808Likely Benign0.386AmbiguousLikely Benign0.070Likely Benign-0.47Neutral0.659Possibly Damaging0.775Possibly Damaging4.20Benign0.00Affected0.12680.7498002.8-13.00
c.191T>A
I64K
2D
AIThe SynGAP1 missense variant I64K is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Tools that predict a pathogenic effect are SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic, while the SGM‑Consensus remains benign; Foldetta results are unavailable. Overall, the majority of predictions lean toward a benign impact, and this conclusion does not contradict the ClinVar status, which contains no report for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.422041Structured0.475481Uncertain0.4780.7470.125-3.206Likely Benign0.964Likely PathogenicLikely Pathogenic0.159Likely Benign-0.47Neutral0.334Benign0.029Benign4.07Benign0.00Affected0.08780.0740-2-3-8.415.01
c.2314T>C
F772L
2D
AIThe SynGAP1 missense variant F772L is listed in gnomAD (6‑33442472‑T‑C) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv, PolyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.450668Structured0.922662Binding0.3290.8840.2506-33442472-T-C11.28e-6-1.751Likely Benign0.762Likely PathogenicLikely Benign0.161Likely Benign-0.47Neutral0.508Possibly Damaging0.786Possibly Damaging4.31Benign1.00Tolerated3.6460.16610.3033021.0-34.02
c.2316C>A
F772L
2D
AIThe SynGAP1 missense variant F772L is catalogued in gnomAD (ID 6‑33442474‑C‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, SGM‑Consensus is Likely Benign, while Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta) has no available result for this variant. Overall, the preponderance of evidence indicates that F772L is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.450668Structured0.922662Binding0.3290.8840.2506-33442474-C-A-1.751Likely Benign0.762Likely PathogenicLikely Benign0.109Likely Benign-0.47Neutral0.508Possibly Damaging0.786Possibly Damaging4.31Benign1.00Tolerated3.6460.16610.3033021.0-34.02
c.2316C>G
F772L
2D
AIThe SynGAP1 missense variant F772L has no ClinVar record and is not listed in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; no Foldetta stability data are available, so it is treated as unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the absence of a ClinVar classification, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.450668Structured0.922662Binding0.3290.8840.250-1.751Likely Benign0.762Likely PathogenicLikely Benign0.109Likely Benign-0.47Neutral0.508Possibly Damaging0.786Possibly Damaging4.31Benign1.00Tolerated3.6460.16610.3033021.0-34.02
c.2461T>A
C821S
2D
AIThe SynGAP1 missense variant C821S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, whereas the SGM‑Consensus (majority vote) supports a benign outcome. Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for C821S, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.672821Binding0.3510.8830.750-0.425Likely Benign0.898Likely PathogenicAmbiguous0.190Likely Benign-0.47Neutral0.997Probably Damaging0.994Probably Damaging2.91Benign1.00Tolerated0.52840.2012Weaken0-1-3.3-16.06
c.2462G>C
C821S
2D
AIThe SynGAP1 missense variant C821S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, whereas the SGM‑Consensus (majority vote) supports a benign outcome. Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for C821S, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.672821Binding0.3510.8830.750-0.425Likely Benign0.898Likely PathogenicAmbiguous0.314Likely Benign-0.47Neutral0.997Probably Damaging0.994Probably Damaging2.91Benign1.00Tolerated0.52840.2012Weaken0-1-3.3-16.06
c.2480T>C
I827T
2D
AIThe SynGAP1 missense variant I827T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, SGM‑Consensus as likely benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.590140Disordered0.636272Binding0.3830.8840.625-4.586Likely Benign0.874Likely PathogenicAmbiguous0.147Likely Benign-0.47Neutral0.997Probably Damaging0.994Probably Damaging2.74Benign0.40Tolerated0.10020.06850-1-5.2-12.05
c.2545G>A
D849N
2D
AIThe SynGAP1 missense variant D849N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that D849N is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.712013Disordered0.554191Binding0.3190.8130.500-5.081Likely Benign0.149Likely BenignLikely Benign0.063Likely Benign-0.47Neutral0.002Benign0.003Benign4.22Benign0.00Affected0.17230.8380210.0-0.98
c.2866T>G
S956A
2D
AIThe SynGAP1 missense variant S956A is not reported in ClinVar or gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify it as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports it as likely benign. Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta stability analysis is unavailable. Overall, the collective evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.957345Binding0.3640.9170.750-4.468Likely Benign0.087Likely BenignLikely Benign0.111Likely Benign-0.47Neutral0.112Benign0.039Benign2.18Pathogenic0.13Tolerated0.42390.4838112.6-16.00
c.294T>A
H98Q
2D
AIThe SynGAP1 missense variant H98Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.631713Binding0.3480.8720.625-2.749Likely Benign0.104Likely BenignLikely Benign0.088Likely Benign-0.47Neutral0.002Benign0.000Benign4.26Benign0.00Affected0.18310.434730-0.3-9.01
c.294T>G
H98Q
2D
AIThe SynGAP1 missense variant H98Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.631713Binding0.3480.8720.625-2.749Likely Benign0.104Likely BenignLikely Benign0.088Likely Benign-0.47Neutral0.002Benign0.000Benign4.26Benign0.00Affected0.18310.434730-0.3-9.01
c.3169A>G
S1057G
2D
AIThe SynGAP1 missense variant S1057G is reported in gnomAD (ID 6‑33443721‑A‑G) but has no ClinVar entry. All evaluated in‑silico predictors uniformly classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. The high‑accuracy consensus methods likewise support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are unavailable. Consequently, the variant is most likely benign based on current predictions, and this assessment does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.8756-33443721-A-G17.20e-7-1.005Likely Benign0.049Likely BenignLikely Benign0.211Likely Benign-0.47Neutral0.421Benign0.111Benign5.76Benign0.52Tolerated3.7750.26540.4846010.4-30.03
c.31G>A
G11R
2D
AIThe SynGAP1 missense variant G11R is catalogued in gnomAD (ID 6‑33420295‑G‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions come from polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.444081Structured0.501027Binding0.3480.9150.3756-33420295-G-A-3.418Likely Benign0.428AmbiguousLikely Benign0.102Likely Benign-0.47Neutral0.498Possibly Damaging0.026Benign3.92Benign0.00Affected4.3210.10220.4596-2-3-4.199.14
c.31G>C
G11R
2D
AIThe SynGAP1 missense variant G11R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.444081Structured0.501027Binding0.3480.9150.375-3.418Likely Benign0.428AmbiguousLikely Benign0.109Likely Benign-0.47Neutral0.498Possibly Damaging0.026Benign3.92Benign0.00Affected4.3210.10220.4596-2-3-4.199.14
c.383C>T
P128L
2D
AIThe SynGAP1 missense variant P128L is catalogued in gnomAD (6‑33432248‑C‑T) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The high‑accuracy AlphaMissense‑Optimized score is benign, and the SGM‑Consensus also indicates a likely benign outcome; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this assessment does not contradict any ClinVar status (none is reported). Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.497853Structured0.713069Binding0.3760.8780.6256-33432248-C-T16.20e-7-4.791Likely Benign0.541AmbiguousLikely Benign0.087Likely Benign-0.47Neutral0.952Possibly Damaging0.500Possibly Damaging4.20Benign0.38Tolerated3.7440.25480.5137-3-35.416.04
c.866T>C
M289T
2D
AIThe SynGAP1 missense variant M289T is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Functional prediction tools that classify the variant as benign include REVEL, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and FATHMM. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized scores the variant as benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is labeled likely benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also predicts a benign effect. Taken together, the majority of evidence indicates that M289T is most likely benign, and this conclusion does not contradict the current ClinVar status of uncertain significance.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.127496Structured0.403499Uncertain0.8860.2760.000Uncertain1-4.668Likely Benign0.238Likely BenignLikely Benign0.73Ambiguous0.10.17Likely Benign0.45Likely Benign-0.01Likely Benign0.222Likely Benign-0.47Neutral0.801Possibly Damaging0.315Benign1.83Pathogenic0.57Tolerated0.16570.1534-1-1-2.6-30.09
c.218G>A
R73K
2D
AIThe SynGAP1 missense variant R73K is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33425826‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized returns a benign prediction, and the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign effect, which does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.501700Disordered0.453164Uncertain0.3320.8260.375Uncertain 16-33425826-G-A21.24e-6-4.033Likely Benign0.151Likely BenignLikely Benign0.077Likely Benign-0.46Neutral0.053Benign0.007Benign4.14Benign0.00Affected4.3210.51940.4428Weaken230.6-28.01
c.2231A>C
Q744P
2D
AIThe SynGAP1 missense variant Q744P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence points to a benign impact for Q744P, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.540428Binding0.3160.8660.875-2.062Likely Benign0.063Likely BenignLikely Benign0.080Likely Benign-0.46Neutral0.784Possibly Damaging0.206Benign2.82Benign0.12Tolerated0.25840.43970-11.9-31.01
c.2243T>A
L748Q
2D
AIThe SynGAP1 missense variant L748Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for L748Q, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.611637Binding0.3390.8630.750-3.177Likely Benign0.119Likely BenignLikely Benign0.060Likely Benign-0.46Neutral0.912Possibly Damaging0.611Possibly Damaging2.74Benign0.01Affected0.12350.1246-2-2-7.314.97
c.2320G>A
A774T
2D
AIThe SynGAP1 missense variant A774T is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on current predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.450668Structured0.905168Binding0.3360.8970.250-3.238Likely Benign0.093Likely BenignLikely Benign0.062Likely Benign-0.46Neutral0.037Benign0.063Benign4.20Benign0.39Tolerated0.14360.757810-2.530.03
c.2321C>A
A774D
2D
AIThe SynGAP1 missense variant A774D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.450668Structured0.905168Binding0.3360.8970.250-4.455Likely Benign0.603Likely PathogenicLikely Benign0.123Likely Benign-0.46Neutral0.570Possibly Damaging0.386Benign4.21Benign0.06Tolerated0.16450.17930-2-5.344.01
c.2977C>G
P993A
2D
AIThe SynGAP1 missense variant P993A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign. Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.923979Binding0.3190.9080.750-4.030Likely Benign0.052Likely BenignLikely Benign0.036Likely Benign-0.46Neutral0.001Benign0.006Benign4.26Benign0.07Tolerated0.34870.49911-13.4-26.04
c.3109A>C
I1037L
2D
AIThe SynGAP1 missense variant I1037L is not reported in ClinVar and is absent from gnomAD, indicating no known clinical or population evidence. Functional prediction tools uniformly favor a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity, and the only uncertain call comes from AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports the variant as “Likely Benign.” High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that I1037L is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-2.563Likely Benign0.448AmbiguousLikely Benign0.074Likely Benign-0.46Neutral0.421Benign0.128Benign2.82Benign0.81Tolerated0.09390.430222-0.70.00
c.3158G>T
S1053I
2D
AIThe SynGAP1 missense variant S1053I is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that S1053I is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.875-6.572Likely Benign0.177Likely BenignLikely Benign0.250Likely Benign-0.46Neutral0.925Possibly Damaging0.413Benign5.32Benign0.10Tolerated0.15360.4780-1-25.326.08
c.3343A>C
I1115L
2D
AIThe SynGAP1 missense variant I1115L is listed in ClinVar (ID 4178654) with an “Uncertain” status and is present in gnomAD (variant ID 6‑33443895‑A‑C). All evaluated in‑silico predictors classify the substitution as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool reports a pathogenic effect, so the pathogenic‑prediction group is empty. High‑accuracy assessments reinforce this benign consensus: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status is unavailable. Overall, the computational evidence strongly supports a benign impact, and this does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.892339Binding0.3080.9120.750Uncertain 16-33443895-A-C17.56e-7-2.308Likely Benign0.067Likely BenignLikely Benign0.120Likely Benign-0.46Neutral0.004Benign0.007Benign2.82Benign1.00Tolerated4.3220.11540.457522-0.70.00
c.3367G>C
G1123R
2D
AIThe SynGAP1 missense variant G1123R is not reported in ClinVar (no entry) and is absent from gnomAD. Consensus from routine in silico predictors shows a split: benign calls come from REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Optimized, whereas pathogenic calls arise from polyPhen‑2 HumDiv and ESM1b; AlphaMissense‑Default remains uncertain. High‑accuracy assessment further supports a benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign outcome, and no Foldetta stability data are available. Consequently, the overall evidence points to a benign effect for G1123R. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing clinical classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.837511Disordered0.827246Binding0.3460.9340.875-9.104Likely Pathogenic0.525AmbiguousLikely Benign0.330Likely Benign-0.46Neutral0.802Possibly Damaging0.435Benign4.34Benign0.57Tolerated0.09330.4342-3-2-4.199.14
c.344A>G
Q115R
2D
AIThe SynGAP1 missense variant Q115R is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority of high‑accuracy predictors—AlphaMissense‑Optimized and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN)—also support a benign classification. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact, and AlphaMissense‑Default remains uncertain. No Foldetta stability analysis is available. Overall, the preponderance of evidence from both general and high‑accuracy tools points to a benign effect for Q115R. This assessment is consistent with the absence of a ClinVar claim, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.657256Binding0.3270.8780.750-1.429Likely Benign0.497AmbiguousLikely Benign0.109Likely Benign-0.46Neutral0.967Probably Damaging0.901Possibly Damaging4.12Benign0.24Tolerated0.14690.150711-1.028.06
c.3475T>G
S1159A
2D
AIThe SynGAP1 missense variant S1159A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict the variant to be pathogenic. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.626927Disordered0.867068Binding0.3430.8460.375-3.653Likely Benign0.327Likely BenignLikely Benign0.095Likely Benign-0.46Neutral0.979Probably Damaging0.982Probably Damaging2.71Benign0.44Tolerated0.47540.4541112.6-16.00
c.3781A>G
S1261G
2D
AIThe SynGAP1 missense variant S1261G is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates benign; Foldetta results are not available. Overall, the majority of evidence supports a benign impact for S1261G, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.501700Disordered0.671500Binding0.8890.5740.250-5.042Likely Benign0.087Likely BenignLikely Benign0.063Likely Benign-0.46Neutral0.005Benign0.013Benign2.32Pathogenic0.65Tolerated0.20630.3477100.4-30.03
c.47T>C
M16T
2D
AIThe SynGAP1 missense variant M16T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign and the SGM‑Consensus classifies it as likely benign. No Foldetta stability analysis is available for this residue, so folding‑stability evidence is lacking. Overall, the majority of computational evidence indicates that M16T is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.440853Structured0.459925Uncertain0.3460.9080.375-2.060Likely Benign0.515AmbiguousLikely Benign0.065Likely Benign-0.46Neutral0.006Benign0.001Benign4.23Benign0.00Affected0.23850.2545-1-1-2.6-30.09
c.1621G>T
A541S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A541S is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools overwhelmingly indicate a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign) all classify the change as tolerated. In contrast, only three tools—polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM—predict a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized reports Benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign; and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts Benign. No prediction or folding stability result is missing or inconclusive. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.050641Structured0.029947Uncertain0.9550.3650.000-5.941Likely Benign0.187Likely BenignLikely Benign0.15Likely Benign0.00.18Likely Benign0.17Likely Benign0.35Likely Benign0.347Likely Benign-0.45Neutral0.983Probably Damaging0.993Probably Damaging-1.27Pathogenic0.44Tolerated0.21820.334011-2.616.00
c.2270G>C
G757A
2D
AIThe SynGAP1 missense change G757A is catalogued in ClinVar (ID 3635272.0) with an uncertain significance designation and is not reported in gnomAD. Functional prediction algorithms uniformly classify the variant as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. No tool in the dataset predicts pathogenicity. High‑accuracy consensus methods corroborate this view: the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect, and AlphaMissense‑Optimized also predicts benign. The Foldetta stability assessment is unavailable for this variant. Taken together, the evidence overwhelmingly supports a benign interpretation, which is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.436924Structured0.830995Binding0.3100.8690.375Uncertain 1-2.626Likely Benign0.091Likely BenignLikely Benign0.066Likely Benign-0.45Neutral0.267Benign0.127Benign2.73Benign0.35Tolerated0.36900.3842102.214.03
c.2384C>T
P795L
2D
AIThe SynGAP1 missense variant P795L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a “Likely Benign” status. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) confirms a benign outcome. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the preponderance of evidence indicates that P795L is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.972450Disordered0.410339Uncertain0.4570.9030.875-2.677Likely Benign0.070Likely BenignLikely Benign0.047Likely Benign-0.45Neutral0.016Benign0.010Benign4.27Benign0.04Affected0.23720.6499-3-35.416.04
c.2503C>A
L835M
2D
AIThe SynGAP1 missense variant L835M is listed in ClinVar (ID 2731331) with an uncertain significance designation and is not reported in gnomAD. Consensus from multiple in‑silico predictors shows a predominance of benign calls: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a neutral effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) classify the substitution as pathogenic. High‑accuracy tools further support a benign interpretation: AlphaMissense‑Optimized reports benign, and the SGM‑Consensus (majority vote) is likely benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, which does not contradict the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.608892Disordered0.642742Binding0.3190.8630.125Conflicting 2-4.153Likely Benign0.121Likely BenignLikely Benign0.068Likely Benign-0.45Neutral0.999Probably Damaging0.977Probably Damaging2.67Benign0.12Tolerated3.7750.07240.383924-1.918.03
c.2866T>A
S956T
2D
AIThe SynGAP1 missense variant S956T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign impact for S956T, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.957345Binding0.3640.9170.750-5.404Likely Benign0.097Likely BenignLikely Benign0.079Likely Benign-0.45Neutral0.369Benign0.159Benign2.00Pathogenic0.08Tolerated0.22440.5727110.114.03
c.2869C>A
H957N
2D
AIThe SynGAP1 missense variant H957N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only FATHMM predicts a pathogenic outcome. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign status. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.968874Binding0.3620.9150.750-6.804Likely Benign0.090Likely BenignLikely Benign0.053Likely Benign-0.45Neutral0.144Benign0.058Benign2.45Pathogenic0.50Tolerated0.23430.378821-0.3-23.04
c.2890C>G
H964D
2D
AIThe SynGAP1 missense variant H964D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic prediction comes from ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-11.061Likely Pathogenic0.207Likely BenignLikely Benign0.124Likely Benign-0.45Neutral0.000Benign0.000Benign4.18Benign0.24Tolerated0.23130.29231-1-0.3-22.05
c.2980A>C
K994Q
2D
AIThe SynGAP1 missense variant K994Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.930054Binding0.2890.9120.750-1.947Likely Benign0.124Likely BenignLikely Benign0.105Likely Benign-0.45Neutral0.002Benign0.004Benign4.16Benign0.03Affected0.49750.1889110.4-0.04
c.3229A>T
T1077S
2D
AIThe SynGAP1 missense variant T1077S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on current predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.903857Disordered0.988141Binding0.3290.8920.750-2.929Likely Benign0.201Likely BenignLikely Benign0.114Likely Benign-0.45Neutral0.068Benign0.025Benign4.32Benign0.06Tolerated0.27880.463511-0.1-14.03
c.3456G>C
E1152D
2D
AIThe SynGAP1 missense variant E1152D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and AlphaMissense‑Default predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the preponderance of evidence points to the variant being most likely benign, and this conclusion does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.741537Disordered0.811118Binding0.3950.8460.500-3.488Likely Benign0.669Likely PathogenicLikely Benign0.171Likely Benign-0.45Neutral0.992Probably Damaging0.989Probably Damaging2.76Benign0.51Tolerated0.21510.4770320.0-14.03
c.3456G>T
E1152D
2D
AIThe SynGAP1 missense variant E1152D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to the variant being most likely benign, and this conclusion does not contradict any ClinVar status, as none is currently assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.741537Disordered0.811118Binding0.3950.8460.500-3.488Likely Benign0.669Likely PathogenicLikely Benign0.171Likely Benign-0.45Neutral0.992Probably Damaging0.989Probably Damaging2.76Benign0.51Tolerated0.21510.4770320.0-14.03
c.3847C>A
P1283T
2D
AIThe SynGAP1 missense variant P1283T is catalogued in gnomAD (ID 6‑33447895‑C‑A) but has no ClinVar entry. Across a broad panel of in silico predictors, every tool reports a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool in the set predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized returns a benign prediction, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence overwhelmingly supports a benign effect, and this is consistent with the absence of a ClinVar pathogenic classification. Therefore, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.762850Disordered0.819686Binding0.4840.7320.8756-33447895-C-A-4.781Likely Benign0.064Likely BenignLikely Benign0.071Likely Benign-0.45Neutral0.451Benign0.193Benign2.76Benign0.11Tolerated3.7750.12690.3784-100.93.99
c.56C>G
A19G
2D
AIThe SynGAP1 missense variant A19G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. The prediction is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.529623Disordered0.443393Uncertain0.3780.9060.500-3.525Likely Benign0.194Likely BenignLikely Benign0.037Likely Benign-0.45Neutral0.371Benign0.036Benign4.10Benign0.00Affected0.23240.544710-2.2-14.03
c.8G>A
R3K
2D
AIThe SynGAP1 missense variant R3K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta results are not available for this variant. Overall, the majority of evidence points to a benign effect. The prediction is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.538167Disordered0.550331Binding0.3580.9200.875-4.378Likely Benign0.254Likely BenignLikely Benign0.062Likely Benign-0.45Neutral0.001Benign0.000Benign4.09Benign0.00Affected0.58420.4564Weaken320.6-28.01
c.1109G>A
G370D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G370D is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are FoldX, FATHMM, and AlphaMissense‑Default. The high‑accuracy methods give mixed results: AlphaMissense‑Optimized predicts benign, Foldetta (a folding‑stability method that integrates FoldX‑MD and Rosetta outputs) predicts pathogenic, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive because it yields an equal split of benign and pathogenic calls. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.461924Structured0.434325Uncertain0.3590.7200.500-5.332Likely Benign0.597Likely PathogenicLikely Benign3.64Destabilizing3.80.83Ambiguous2.24Destabilizing0.30Likely Benign0.372Likely Benign-0.44Neutral0.007Benign0.001Benign1.32Pathogenic0.64Tolerated0.16320.14941-1-3.158.04
c.1127G>C
G376A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 G376A missense variant is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, Foldetta, premPS, PROVEAN, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. FoldX and Rosetta give uncertain results and are not considered evidence for either side. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates benign; and Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, predicts benign. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.680603Disordered0.428979Uncertain0.3260.8690.625-6.016Likely Benign0.099Likely BenignLikely Benign1.74Ambiguous0.3-0.84Ambiguous0.45Likely Benign0.00Likely Benign0.392Likely Benign-0.44Neutral0.999Probably Damaging0.995Probably Damaging1.33Pathogenic0.03Affected0.38680.4465102.214.03
c.1165T>C
S389P
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S389P is listed in gnomAD (variant ID 6‑33438070‑T‑C) and has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, Foldetta, premPS, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus is likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) also predicts benign. No prediction or stability result is missing or inconclusive. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.703578Disordered0.417444Uncertain0.3060.8030.8756-33438070-T-C-5.286Likely Benign0.130Likely BenignLikely Benign1.85Ambiguous2.0-0.99Ambiguous0.43Likely Benign0.16Likely Benign0.460Likely Benign-0.44Neutral0.676Possibly Damaging0.693Possibly Damaging5.05Benign0.01Affected4.3280.30980.7002-11-0.810.04
c.2570G>T
S857I
2D
AIThe SynGAP1 missense variant S857I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. ESM1b is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for S857I, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.728858Disordered0.475747Uncertain0.2880.8260.375-7.092In-Between0.192Likely BenignLikely Benign0.198Likely Benign-0.44Neutral0.997Probably Damaging0.995Probably Damaging4.04Benign0.05Affected0.10700.6208-1-25.326.08
c.2822C>T
P941L
2D
AIThe SynGAP1 missense variant P941L is listed in ClinVar (ID 3451960.0) with an “Uncertain” status and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). The only tool that predicts a pathogenic outcome is SIFT. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates “Likely Benign.” No Foldetta (FoldX‑MD/Rosetta) stability result is available, so it does not influence the assessment. Overall, the majority of predictions, including the high‑accuracy tools, point to a benign effect, which is consistent with the ClinVar “Uncertain” designation rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.874069Disordered0.900790Binding0.4030.9060.625Uncertain 2-5.692Likely Benign0.066Likely BenignLikely Benign0.054Likely Benign-0.44Neutral0.144Benign0.039Benign2.76Benign0.01Affected0.21960.5931-3-35.416.04
c.2910G>C
E970D
2D
AIThe SynGAP1 missense variant E970D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification—there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.951925Disordered0.953422Binding0.3420.9020.750-3.381Likely Benign0.062Likely BenignLikely Benign0.063Likely Benign-0.44Neutral0.001Benign0.001Benign4.14Benign0.33Tolerated0.27290.4610320.0-14.03
c.2910G>T
E970D
2D
AIThe SynGAP1 missense variant E970D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.951925Disordered0.953422Binding0.3420.9020.750-3.381Likely Benign0.062Likely BenignLikely Benign0.063Likely Benign-0.44Neutral0.001Benign0.001Benign4.14Benign0.33Tolerated0.27290.4610320.0-14.03
c.3574C>A
L1192M
2D
AIThe SynGAP1 missense variant L1192M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv flags the variant as pathogenic, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports a benign likelihood. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.575842Disordered0.441757Uncertain0.7620.6090.625-4.591Likely Benign0.195Likely BenignLikely Benign0.092Likely Benign-0.44Neutral0.606Possibly Damaging0.287Benign2.66Benign0.16Tolerated0.06690.248642-1.918.03
c.3762G>C
E1254D
2D
AIThe SynGAP1 missense change E1254D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports it as “Likely Benign.” In contrast, only the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is “Likely Benign.” Foldetta results are not available, so they do not influence the overall assessment. Overall, the majority of evidence indicates that E1254D is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.657645Disordered0.403242Uncertain0.8860.5550.625-4.648Likely Benign0.274Likely BenignLikely Benign0.112Likely Benign-0.44Neutral0.997Probably Damaging0.992Probably Damaging2.62Benign0.51Tolerated0.14020.3471320.0-14.03
c.3762G>T
E1254D
2D
AIThe SynGAP1 missense change E1254D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that E1254D is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.657645Disordered0.403242Uncertain0.8860.5550.625-4.648Likely Benign0.274Likely BenignLikely Benign0.112Likely Benign-0.44Neutral0.997Probably Damaging0.992Probably Damaging2.62Benign0.51Tolerated0.14020.3471320.0-14.03
c.4A>C
S2R
2D
AIThe SynGAP1 missense variant S2R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from both general and high‑accuracy predictors indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.543646Binding0.3820.9220.750-3.684Likely Benign0.426AmbiguousLikely Benign0.062Likely Benign-0.44Neutral0.117Benign0.008Benign4.05Benign0.00Affected4.3210.09960.4503-10-3.769.11
c.52T>G
Y18D
2D
AIThe SynGAP1 missense variant Y18D is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and polyPhen‑2 HumVar, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. No Foldetta stability prediction is available for this variant. Overall, the computational evidence overwhelmingly suggests that Y18D is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.483068Structured0.446314Uncertain0.3450.9080.375-2.783Likely Benign0.580Likely PathogenicLikely Benign0.115Likely Benign-0.44Neutral0.659Possibly Damaging0.072Benign4.06Benign0.00Affected0.42070.1253-4-3-2.2-48.09
c.59C>T
P20L
2D
AIThe SynGAP1 missense variant P20L (ClinVar ID 1185912.0) is listed as “Uncertain” in ClinVar and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as likely benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which remains uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.529623Disordered0.442804Uncertain0.4480.8990.500Uncertain 3-3.289Likely Benign0.464AmbiguousLikely Benign0.100Likely Benign-0.44Neutral0.909Possibly Damaging0.713Possibly Damaging4.27Benign0.00Affected4.3210.24790.7258-3-35.416.04
c.6C>A
S2R
2D
AIThe SynGAP1 missense variant S2R is present in gnomAD (ID 6‑33420270‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score all report benign or likely benign. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors benign. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.543646Binding0.3820.9220.7506-33420270-C-A16.52e-7-3.684Likely Benign0.426AmbiguousLikely Benign0.070Likely Benign-0.44Neutral0.117Benign0.008Benign4.05Benign0.00Affected4.3210.09960.4503-10-3.769.11
c.6C>G
S2R
2D
AIThe SynGAP1 missense variant S2R is not reported in ClinVar (ClinVar ID None) and has no entry in gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status is unavailable. Overall, the preponderance of evidence from multiple prediction tools and high‑accuracy methods indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.543646Binding0.3820.9220.750-3.684Likely Benign0.426AmbiguousLikely Benign0.065Likely Benign-0.44Neutral0.117Benign0.008Benign4.05Benign0.00Affected4.3210.09960.4503-10-3.769.11
c.739C>A
Q247K
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q247K (PH domain) is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include FoldX, premPS, PROVEAN, SIFT, FATHMM, AlphaMissense‑Optimized, and polyPhen2_HumVar. Tools that predict a pathogenic effect are REVEL, polyPhen2_HumDiv, and ESM1b. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, favors a benign outcome (2 benign vs. 1 pathogenic). High‑accuracy methods all support benignity: AlphaMissense‑Optimized is benign, the SGM Consensus is benign, and Foldetta (combining FoldX‑MD and Rosetta) is benign. Uncertain results from AlphaMissense‑Default and Rosetta are treated as unavailable. Overall, the collective evidence points to a benign impact for Q247K, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
PH0.490133Structured0.283012Uncertain0.8220.3390.250-10.377Likely Pathogenic0.502AmbiguousLikely Benign-0.28Likely Benign0.10.74Ambiguous0.23Likely Benign-0.13Likely Benign0.529Likely Pathogenic-0.44Neutral0.787Possibly Damaging0.351Benign5.89Benign0.13Tolerated0.13660.275811-0.40.04
c.991T>G
S331A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S331A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only FATHMM predicts pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a benign majority vote (3 benign vs. 1 pathogenic). High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign; the SGM‑Consensus (majority vote) is benign; and Foldetta, combining FoldX‑MD and Rosetta outputs, is benign. No prediction or folding‑stability result is missing or inconclusive. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.433034Structured0.346458Uncertain0.6580.4750.250-2.199Likely Benign0.101Likely BenignLikely Benign0.22Likely Benign0.1-0.08Likely Benign0.07Likely Benign-0.15Likely Benign0.071Likely Benign-0.44Neutral0.139Benign0.060Benign1.89Pathogenic0.67Tolerated0.53140.3008Weaken112.6-16.00
c.137C>A
P46H
2D
AIThe SynGAP1 missense variant P46H is evaluated by multiple in silico tools. Consensus from SGM‑Consensus indicates a likely benign effect, and the variant is not reported in ClinVar or gnomAD. Functional predictors that agree on a benign outcome include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Predictors that flag a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports likely benign, while Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact for P46H, and this conclusion is not contradicted by any ClinVar annotation. The variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.390993Structured0.433588Uncertain0.5490.7410.375-4.022Likely Benign0.428AmbiguousLikely Benign0.097Likely Benign-0.43Neutral0.992Probably Damaging0.977Probably Damaging4.10Benign0.00Affected0.23600.52290-2-1.640.02
c.202C>G
L68V
2D
AIThe SynGAP1 missense variant L68V has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized independently predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.470567Uncertain0.4050.7680.250-4.079Likely Benign0.470AmbiguousLikely Benign0.028Likely Benign-0.43Neutral0.458Possibly Damaging0.364Benign4.13Benign0.00Affected0.10770.2817210.4-14.03
c.2101C>A
P701T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant P701T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly classify the substitution as benign: REVEL, premPS, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate a tolerated change. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign; the SGM Consensus, derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports benign. Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, is inconclusive, and FoldX alone is uncertain, so these results are treated as unavailable. Overall, the evidence strongly supports a benign effect for P701T, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.074921Structured0.404318Uncertain0.9180.3450.000-6.920Likely Benign0.272Likely BenignLikely Benign1.61Ambiguous0.00.11Likely Benign0.86Ambiguous-0.18Likely Benign0.144Likely Benign-0.43Neutral0.084Benign0.050Benign3.44Benign0.70Tolerated0.13980.41600-10.93.99
c.2231A>G
Q744R
2D
AIThe SynGAP1 missense variant Q744R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign. Foldetta results are unavailable. Overall, the majority of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.540428Binding0.3160.8660.875-2.207Likely Benign0.108Likely BenignLikely Benign0.062Likely Benign-0.43Neutral0.001Benign0.002Benign2.80Benign0.05Affected0.14370.158811-1.028.06
c.2314T>G
F772V
2D
AIThe SynGAP1 missense variant F772V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are not available for this variant. Overall, the majority of computational evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.450668Structured0.922662Binding0.3290.8840.250-2.886Likely Benign0.191Likely BenignLikely Benign0.161Likely Benign-0.43Neutral0.845Possibly Damaging0.899Possibly Damaging4.27Benign0.37Tolerated0.16870.2419-1-11.4-48.04
c.2636C>G
A879G
2D
AIThe SynGAP1 missense variant A879G is reported in gnomAD (variant ID 6-33443188-C-G) but has no ClinVar entry. Functional prediction tools uniformly classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate a benign effect. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available, so they do not influence the assessment. Based on the collective predictions, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.608892Disordered0.622695Binding0.2770.8740.2506-33443188-C-G16.20e-7-3.924Likely Benign0.085Likely BenignLikely Benign0.054Likely Benign-0.43Neutral0.001Benign0.007Benign2.69Benign0.43Tolerated3.7750.22140.436201-2.2-14.03
c.2828G>T
G943V
2D
AIThe SynGAP1 missense variant G943V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. The only tool with an uncertain outcome is ESM1b, which does not alter the overall consensus. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign classification. High‑accuracy predictors corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are not available. Taken together, the evidence overwhelmingly supports a benign interpretation, and there is no conflict with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.973328Disordered0.860437Binding0.3720.9100.750-7.658In-Between0.092Likely BenignLikely Benign0.265Likely Benign-0.43Neutral0.224Benign0.062Benign2.85Benign0.16Tolerated0.13990.3507-1-34.642.08
c.2861C>T
P954L
2D
AIThe SynGAP1 missense variant P954L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984159Disordered0.932268Binding0.4650.9260.750-5.607Likely Benign0.092Likely BenignLikely Benign0.097Likely Benign-0.43Neutral0.977Probably Damaging0.812Possibly Damaging2.78Benign0.55Tolerated0.23460.5867-3-35.416.04
c.3380G>C
G1127A
2D
AIThe SynGAP1 missense variant G1127A is listed in ClinVar (ID 426748.0) with an uncertain significance status and is present in gnomAD (variant ID 6‑33443932‑G‑C). Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the variant as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability predictor combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status is unavailable. Overall, the evidence strongly supports a benign classification, which does not contradict the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.899122Disordered0.852422Binding0.3440.9150.875Conflicting 46-33443932-G-C42.68e-6-5.949Likely Benign0.080Likely BenignLikely Benign0.164Likely Benign-0.43Neutral0.001Benign0.002Benign4.83Benign1.00Tolerated4.3240.34200.4933102.214.03
c.3736A>C
K1246Q
2D
AIThe SynGAP1 missense change K1246Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports it as “Likely Benign.” In contrast, the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that K1246Q is most likely benign, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.750527Disordered0.375382Uncertain0.8870.5640.625-0.718Likely Benign0.107Likely BenignLikely Benign0.071Likely Benign-0.43Neutral0.961Probably Damaging0.721Possibly Damaging2.66Benign0.06Tolerated0.37080.0740110.4-0.04
c.104T>A
V35D
2D
AIThe SynGAP1 missense variant V35D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the overall assessment. Overall, the majority of evidence points to the variant being most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.613573Disordered0.434838Uncertain0.3600.8510.375-4.232Likely Benign0.321Likely BenignLikely Benign0.125Likely Benign-0.42Neutral0.824Possibly Damaging0.828Possibly Damaging4.18Benign0.00Affected0.15400.1547-2-3-7.715.96
c.2186A>G
N729S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant N729S is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). No tool in the dataset predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus also as benign, while Foldetta (combining FoldX‑MD and Rosetta outputs) is inconclusive. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.750527Disordered0.426547Uncertain0.6510.5830.625Uncertain 1-1.578Likely Benign0.066Likely BenignLikely Benign0.14Likely Benign0.11.34Ambiguous0.74Ambiguous-0.36Likely Benign0.063Likely Benign-0.42Neutral0.221Benign0.027Benign3.38Benign0.93Tolerated3.5970.34110.4854112.7-27.03
c.2242C>G
L748V
2D
AIThe SynGAP1 missense variant L748V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.611637Binding0.3390.8630.750-3.454Likely Benign0.078Likely BenignLikely Benign0.045Likely Benign-0.42Neutral0.679Possibly Damaging0.216Benign2.74Benign0.05Affected0.16800.3485210.4-14.03
c.2257G>A
A753T
2D
AIThe SynGAP1 missense variant A753T is catalogued in gnomAD (ID 6‑33441722‑G‑A) but has no ClinVar entry. Across the spectrum of in‑silico predictors, every tool listed—REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—consistently classifies the change as benign. No pathogenic predictions are reported. Grouping by agreement, all available tools fall into the benign category, with no tools indicating pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status remains unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.521092Disordered0.722781Binding0.3810.8730.6256-33441722-G-A21.24e-6-4.298Likely Benign0.069Likely BenignLikely Benign0.071Likely Benign-0.42Neutral0.022Benign0.018Benign2.70Benign0.28Tolerated3.9950.16720.699701-2.530.03
c.2480T>G
I827S
2D
AIThe SynGAP1 missense variant I827S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is Likely Benign, and AlphaMissense‑Optimized is classified as Uncertain. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, which has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.590140Disordered0.636272Binding0.3830.8840.625-3.693Likely Benign0.849Likely PathogenicAmbiguous0.140Likely Benign-0.42Neutral0.999Probably Damaging0.996Probably Damaging2.70Benign0.29Tolerated0.28910.0512-1-2-5.3-26.08
c.2578G>A
V860I
2D
AIThe SynGAP1 missense variant V860I is catalogued in ClinVar as a benign alteration (ClinVar ID 411591.0) and is present in the gnomAD database (gnomAD ID 6‑33443130‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized returns benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” No Foldetta stability prediction is available for this variant. Overall, the consensus of computational evidence strongly favors a benign impact, aligning with the ClinVar designation and showing no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.545602Disordered0.518121Binding0.2690.8030.250Benign 16-33443130-G-A211.30e-5-4.516Likely Benign0.095Likely BenignLikely Benign0.039Likely Benign-0.42Neutral0.009Benign0.006Benign4.24Benign0.00Affected3.7750.08420.4477430.314.03
c.2651G>A
R884Q
2D
AIThe SynGAP1 missense variant R884Q is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443203‑G‑A). All available in silico predictors agree on a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. No tool predicts pathogenicity. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not reported, so they are unavailable. Overall, the computational evidence strongly supports a benign classification, which does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.720929Disordered0.641526Binding0.3050.8980.250Uncertain 26-33443203-G-A53.10e-6-3.785Likely Benign0.128Likely BenignLikely Benign0.055Likely Benign-0.42Neutral0.012Benign0.004Benign2.62Benign0.36Tolerated4.3240.28740.2332111.0-28.06
c.292C>G
H98D
2D
AIThe SynGAP1 missense variant H98D is reported in gnomAD (variant ID 6‑33425900‑C‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) all classify the change as benign. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is “Likely Benign.” No Foldetta stability result is available, so it does not influence the assessment. Overall, the consensus of the available predictions indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.631713Binding0.3480.8720.6256-33425900-C-G16.20e-7-1.739Likely Benign0.167Likely BenignLikely Benign0.140Likely Benign-0.42Neutral0.115Benign0.012Benign4.24Benign0.00Affected4.3210.27320.3018-11-0.3-22.05
c.2992G>T
A998S
2D
AIThe SynGAP1 missense variant A998S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. The variant is therefore most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.759478Disordered0.951758Binding0.3180.9020.500-2.893Likely Benign0.074Likely BenignLikely Benign0.022Likely Benign-0.42Neutral0.611Possibly Damaging0.237Benign4.14Benign0.00Affected0.26740.550611-2.616.00
c.3016T>C
Y1006H
2D
AIThe SynGAP1 missense variant Y1006H is not reported in ClinVar and has no entries in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, and Foldetta results are unavailable. Overall, the balance of evidence favors a benign interpretation, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.801317Disordered0.930554Binding0.2640.8960.750-3.095Likely Benign0.863Likely PathogenicAmbiguous0.116Likely Benign-0.42Neutral1.000Probably Damaging0.999Probably Damaging2.70Benign0.17Tolerated0.24060.089402-1.9-26.03
c.3083T>C
L1028P
2D
AIThe SynGAP1 missense variant L1028P is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only AlphaMissense‑Default predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Taken together, the majority of evidence points to a benign impact for this variant, and there is no ClinVar annotation to contradict this conclusion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.899122Disordered0.995137Binding0.3640.7300.500-3.080Likely Benign0.594Likely PathogenicLikely Benign0.215Likely Benign-0.42Neutral0.004Benign0.010Benign2.70Benign0.25Tolerated0.28460.1763-3-3-5.4-16.04
c.3275T>C
L1092S
2D
AIThe SynGAP1 missense variant L1092S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, SGM‑Consensus as likely benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for this variant. This conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.924947Disordered0.985431Binding0.3850.8901.000-3.649Likely Benign0.900Likely PathogenicAmbiguous0.121Likely Benign-0.42Neutral0.986Probably Damaging0.823Possibly Damaging2.68Benign0.25Tolerated0.30860.1119-3-2-4.6-26.08
c.3400A>T
T1134S
2D
AIThe SynGAP1 missense variant T1134S is not reported in ClinVar and is absent from gnomAD, indicating no documented population frequency. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool predicts pathogenicity. The high‑accuracy consensus, SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN), also reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly supports a benign classification, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.885302Disordered0.813034Binding0.3350.8850.875-3.015Likely Benign0.089Likely BenignLikely Benign0.220Likely Benign-0.42Neutral0.007Benign0.009Benign5.47Benign0.09Tolerated0.31890.466611-0.1-14.03
c.3401C>G
T1134S
2D
AIThe SynGAP1 missense variant T1134S is not reported in ClinVar and is absent from gnomAD, indicating no documented population frequency. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool predicts pathogenicity. The high‑accuracy consensus, SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN), also reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly supports a benign classification, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.885302Disordered0.813034Binding0.3350.8850.875-3.015Likely Benign0.089Likely BenignLikely Benign0.228Likely Benign-0.42Neutral0.007Benign0.009Benign5.47Benign0.09Tolerated0.31890.466611-0.1-14.03
c.3633G>A
M1211I
2D
AIThe SynGAP1 missense variant M1211I is listed in ClinVar with an “Uncertain” status and is present in gnomAD (variant ID 6-33446625-G-A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are AlphaMissense‑Default, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. High‑accuracy predictions therefore point to a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus also indicates benign. Based on the aggregate predictions, the variant is most likely benign, which does not contradict the ClinVar “Uncertain” status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.585406Disordered0.578388Binding0.8760.5650.500Uncertain 16-33446625-G-A31.86e-6-1.537Likely Benign0.764Likely PathogenicLikely Benign0.298Likely Benign-0.42Neutral0.969Probably Damaging0.968Probably Damaging5.40Benign1.00Tolerated3.7750.12140.2839122.6-18.03
c.3633G>C
M1211I
2D
AIThe SynGAP1 missense variant M1211I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently contains no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.585406Disordered0.578388Binding0.8760.5650.500-1.537Likely Benign0.764Likely PathogenicLikely Benign0.298Likely Benign-0.42Neutral0.969Probably Damaging0.968Probably Damaging5.40Benign1.00Tolerated3.7750.12140.2839122.6-18.03
c.3633G>T
M1211I
2D
AIThe SynGAP1 missense variant M1211I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and AlphaMissense‑Default predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as likely benign (three benign votes versus one pathogenic). High‑accuracy assessment by AlphaMissense‑Optimized confirms a benign prediction, whereas the Foldetta stability analysis is unavailable. Overall, the preponderance of evidence points to a benign effect for M1211I, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.585406Disordered0.578388Binding0.8760.5650.500-1.537Likely Benign0.764Likely PathogenicLikely Benign0.298Likely Benign-0.42Neutral0.969Probably Damaging0.968Probably Damaging5.40Benign1.00Tolerated3.7750.12140.2839122.6-18.03
c.3910C>A
P1304T
2D
AIThe SynGAP1 missense variant P1304T is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign classification, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.885302Disordered0.886417Binding0.4750.8660.875-4.454Likely Benign0.072Likely BenignLikely Benign0.091Likely Benign-0.42Neutral0.001Benign0.002Benign2.86Benign0.14Tolerated0.15710.49140-10.93.99
c.64A>G
R22G
2D
AIThe SynGAP1 missense variant R22G is reported in ClinVar as “Not submitted” and is present in gnomAD (ID 6‑33420328‑A‑G). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. Foldetta results are unavailable. Overall, the majority of computational evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which has no pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.538167Disordered0.441505Uncertain0.3770.8910.5006-33420328-A-G-3.628Likely Benign0.322Likely BenignLikely Benign0.185Likely Benign-0.42Neutral0.462Possibly Damaging0.152Benign4.19Benign0.00Affected4.3210.35900.4098-2-34.1-99.14
c.1131G>A
M377I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M377I (ClinVar ID 3803473.0, status = Uncertain) is present in gnomAD (ID = 6‑33438036‑G‑A). Functional prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool in the dataset predicts a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is “Likely Benign,” while Foldetta (combining FoldX‑MD and Rosetta outputs) is inconclusive. Overall, the computational evidence strongly favors a benign classification, which does not contradict the ClinVar status of Uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.675549Disordered0.431183Uncertain0.3240.8840.625Uncertain 16-33438036-G-A16.23e-7-2.895Likely Benign0.212Likely BenignLikely Benign0.76Ambiguous0.30.54Ambiguous0.65Ambiguous0.24Likely Benign0.227Likely Benign-0.41Neutral0.000Benign0.001Benign5.46Benign0.26Tolerated4.32120.22400.4133122.6-18.03
c.1131G>C
M377I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M377I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that reach consensus classify the change as benign: REVEL, premPS, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports a benign effect; the SGM Consensus, derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates benign; Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, yields an uncertain result and is therefore not considered evidence for pathogenicity. Overall, the collective evidence points to a benign impact for M377I, and this conclusion is consistent with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.675549Disordered0.431183Uncertain0.3240.8840.625-2.895Likely Benign0.212Likely BenignLikely Benign0.76Ambiguous0.30.54Ambiguous0.65Ambiguous0.24Likely Benign0.227Likely Benign-0.41Neutral0.000Benign0.001Benign5.46Benign0.26Tolerated4.32120.22400.4133122.6-18.03
c.1131G>T
M377I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M377I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that reach consensus classify the change as benign: REVEL, premPS, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports a benign effect; the SGM Consensus, derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates benign; Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, yields an uncertain result and is therefore not considered evidence for pathogenicity. Overall, the evidence overwhelmingly supports a benign interpretation, and this conclusion does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.675549Disordered0.431183Uncertain0.3240.8840.625-2.895Likely Benign0.212Likely BenignLikely Benign0.76Ambiguous0.30.54Ambiguous0.65Ambiguous0.24Likely Benign0.227Likely Benign-0.41Neutral0.000Benign0.001Benign5.46Benign0.26Tolerated4.32120.22400.4133122.6-18.03
c.1135T>C
S379P
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S379P is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, Rosetta, and Foldetta; FoldX is uncertain. High‑accuracy methods give a mixed picture: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also predicts benign, whereas Foldetta (combining FoldX‑MD and Rosetta outputs) predicts pathogenic. Overall, the majority of evidence—including the high‑accuracy benign predictions—suggests that the variant is most likely benign. This conclusion is not contradicted by ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.728858Disordered0.433206Uncertain0.3270.9310.625-5.007Likely Benign0.118Likely BenignLikely Benign1.10Ambiguous0.82.92Destabilizing2.01Destabilizing0.17Likely Benign0.430Likely Benign-0.41Neutral0.808Possibly Damaging0.212Benign3.83Benign0.10Tolerated0.30350.65941-1-0.810.04
c.181G>C
E61Q
2D
AIThe SynGAP1 missense variant E61Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability result is available. Overall, the majority of evidence points to a benign effect for E61Q, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.352862Structured0.477329Uncertain0.5180.6990.125-5.443Likely Benign0.267Likely BenignLikely Benign0.058Likely Benign-0.41Neutral0.659Possibly Damaging0.775Possibly Damaging4.18Benign0.00Affected0.13440.5617220.0-0.98
c.2178G>C
R726S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant R726S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign; the SGM‑Consensus (majority vote) is Likely Benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also predicts Benign. No prediction or folding stability result is missing or inconclusive. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.521092Disordered0.449098Uncertain0.8880.5130.625-4.780Likely Benign0.753Likely PathogenicLikely Benign0.40Likely Benign0.1-0.07Likely Benign0.17Likely Benign-0.16Likely Benign0.232Likely Benign-0.41Neutral1.000Probably Damaging1.000Probably Damaging2.66Benign0.92Tolerated0.29930.39560-13.7-69.11
c.2178G>T
R726S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant R726S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign; the SGM‑Consensus (majority vote) is Likely Benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also predicts Benign. No prediction or folding stability result is missing or inconclusive. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.521092Disordered0.449098Uncertain0.8880.5130.625-4.780Likely Benign0.753Likely PathogenicLikely Benign0.40Likely Benign0.1-0.07Likely Benign0.17Likely Benign-0.16Likely Benign0.232Likely Benign-0.41Neutral1.000Probably Damaging1.000Probably Damaging2.66Benign0.92Tolerated0.29930.39560-13.7-69.11
c.2305C>G
L769V
2D
AIThe SynGAP1 missense variant L769V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv flags it as pathogenic, but this is the sole discordant call. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.411940Structured0.928432Binding0.3670.8830.250-4.585Likely Benign0.106Likely BenignLikely Benign0.075Likely Benign-0.41Neutral0.625Possibly Damaging0.249Benign4.04Benign0.25Tolerated0.13640.2558210.4-14.03
c.2341A>C
M781L
2D
AIThe SynGAP1 missense variant M781L is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.580690Disordered0.792850Binding0.3420.8890.625-2.334Likely Benign0.140Likely BenignLikely Benign0.143Likely Benign-0.41Neutral0.000Benign0.001Benign2.83Benign0.88Tolerated0.15300.3669421.9-18.03
c.2341A>T
M781L
2D
AIThe SynGAP1 missense variant M781L is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset predicts pathogenicity. High‑accuracy assessments corroborate this benign classification: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign status. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this prediction is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.580690Disordered0.792850Binding0.3420.8890.625-2.334Likely Benign0.140Likely BenignLikely Benign0.143Likely Benign-0.41Neutral0.000Benign0.001Benign2.83Benign0.88Tolerated0.15300.3669421.9-18.03
c.2401G>A
G801S
2D
AIThe SynGAP1 missense variant G801S is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. All available in‑silico predictors classify the change as benign: SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this benign prediction: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is also Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no reported result for this variant. Overall, the evidence strongly supports a benign effect, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.874069Disordered0.636323Binding0.3200.8920.625Uncertain 1-3.665Likely Benign0.087Likely BenignLikely Benign0.039Likely Benign-0.41Neutral0.009Benign0.019Benign2.76Benign0.48Tolerated4.3220.23250.475501-0.430.03
c.2510T>C
V837A
2D
AIThe SynGAP1 missense variant V837A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.525368Disordered0.626284Binding0.3180.8710.125-1.400Likely Benign0.370AmbiguousLikely Benign0.073Likely Benign-0.41Neutral0.992Probably Damaging0.989Probably Damaging2.70Benign1.00Tolerated0.30580.210600-2.4-28.05
c.2732T>A
V911D
2D
AIThe SynGAP1 missense variant V911D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of high‑confidence predictors indicate a benign impact, and this is consistent with the lack of ClinVar evidence. Therefore, the variant is most likely benign and does not contradict any existing ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.685117Disordered0.724137Binding0.3270.9140.375-4.422Likely Benign0.624Likely PathogenicLikely Benign0.114Likely Benign-0.41Neutral0.500Possibly Damaging0.157Benign2.71Benign0.05Affected0.14160.1289-2-3-7.715.96
c.2813G>C
G938A
2D
AIThe SynGAP1 missense variant G938A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic impact. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta’s protein‑folding stability analysis is not available for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.905695Disordered0.949795Binding0.3180.8830.625-5.068Likely Benign0.139Likely BenignLikely Benign0.095Likely Benign-0.41Neutral0.979Probably Damaging0.821Possibly Damaging2.80Benign0.82Tolerated0.34620.4948102.214.03
c.2840G>C
G947A
2D
AIThe SynGAP1 missense variant G947A is listed in ClinVar (ID 1595137) as Benign and is present in gnomAD (variant ID 6‑33443392‑G‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool in the dataset predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is Likely Benign, and Foldetta results are unavailable. Overall, the computational evidence strongly indicates that the variant is most likely benign, and this conclusion is consistent with the ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988695Disordered0.850554Binding0.3580.9190.750Benign/Likely benign 26-33443392-G-C281.73e-5-6.511Likely Benign0.080Likely BenignLikely Benign0.156Likely Benign-0.41Neutral0.224Benign0.131Benign4.97Benign0.10Tolerated4.3240.33750.4957102.214.03
c.2851C>A
H951N
2D
AIThe SynGAP1 missense variant H951N is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the evidence strongly supports a benign classification, and this conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-5.833Likely Benign0.074Likely BenignLikely Benign0.140Likely Benign-0.41Neutral0.011Benign0.018Benign5.43Benign0.16Tolerated0.25900.319721-0.3-23.04
c.2951A>G
K984R
2D
AIThe SynGAP1 missense variant K984R is reported in gnomAD (ID 6‑33443503‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the consensus of the majority of tools indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.951648Binding0.2880.8950.7506-33443503-A-G21.24e-6-2.044Likely Benign0.104Likely BenignLikely Benign0.082Likely Benign-0.41Neutral0.012Benign0.012Benign2.67Benign0.00Affected4.3210.50980.1558Weaken23-0.628.01
c.3154G>A
G1052R
2D
AISynGAP1 missense variant G1052R is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Functional prediction tools cluster into two groups: benign predictions from REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized scores the variant as benign, and the SGM consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of evidence points to a benign effect, which does not contradict the ClinVar uncertain status but provides additional support toward a likely benign classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.984420Disordered0.892068Binding0.3670.9380.875Uncertain 1-9.050Likely Pathogenic0.383AmbiguousLikely Benign0.497Likely Benign-0.41Neutral0.990Probably Damaging0.798Possibly Damaging3.90Benign0.10Tolerated3.7750.09760.4142-2-3-4.199.14
c.3154G>C
G1052R
2D
AIThe SynGAP1 missense variant G1052R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and ESM1b predict a pathogenic outcome; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.984420Disordered0.892068Binding0.3670.9380.875-9.050Likely Pathogenic0.383AmbiguousLikely Benign0.497Likely Benign-0.41Neutral0.990Probably Damaging0.798Possibly Damaging3.90Benign0.10Tolerated3.7750.09760.4142-2-3-4.199.14
c.3170G>A
S1057N
2D
AIThe SynGAP1 missense variant S1057N is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. All available in‑silico predictors classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” No tool predicts pathogenicity. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, while Foldetta (combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Overall, the computational evidence overwhelmingly supports a benign effect, and this is consistent with the ClinVar “Uncertain” classification rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.875Uncertain 1-6.386Likely Benign0.117Likely BenignLikely Benign0.218Likely Benign-0.41Neutral0.451Benign0.129Benign5.25Benign0.28Tolerated0.22320.460511-2.727.03
c.3350G>C
G1117A
2D
AIThe SynGAP1 missense variant G1117A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.853192Binding0.3230.9140.750-6.514Likely Benign0.082Likely BenignLikely Benign0.183Likely Benign-0.41Neutral0.152Benign0.071Benign4.61Benign0.23Tolerated0.35450.4944102.214.03
c.3356G>A
G1119E
2D
AIThe SynGAP1 missense variant G1119E is reported in gnomAD (variant ID 6-33443908‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates that G1119E is most likely benign, and this conclusion is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.827927Disordered0.818538Binding0.3390.9280.8756-33443908-G-A16.61e-7-9.151Likely Pathogenic0.338Likely BenignLikely Benign0.284Likely Benign-0.41Neutral0.005Benign0.013Benign3.93Benign0.12Tolerated4.3220.16540.4259-20-3.172.06
c.35G>A
S12N
2D
AIThe SynGAP1 missense variant S12N is listed in ClinVar with no submitted interpretation and is present in gnomAD (variant ID 6‑33420299‑G‑A). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” No Foldetta stability result is available. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.490599Uncertain0.3550.9160.5006-33420299-G-A-4.946Likely Benign0.185Likely BenignLikely Benign0.069Likely Benign-0.41Neutral0.208Benign0.018Benign4.10Benign0.00Affected4.3210.14050.500411-2.727.03
c.388C>A
Q130K
2D
AIThe SynGAP1 missense variant Q130K is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around benign: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate a benign effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy predictors—AlphaMissense‑Optimized and the SGM‑Consensus—both support a benign classification, whereas the pathogenic predictions come from polyPhen‑2 alone. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.509769Disordered0.718853Binding0.3060.8850.375-4.656Likely Benign0.540AmbiguousLikely Benign0.058Likely Benign-0.41Neutral0.924Possibly Damaging0.857Possibly Damaging4.20Benign0.07Tolerated0.20170.447311-0.40.04
c.904T>G
S302A
2D
AIThe SynGAP1 missense variant S302A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and Foldetta. No tool predicts a pathogenic outcome; the only inconclusive result is from Rosetta, which is treated as unavailable. High‑accuracy assessments reinforce the benign prediction: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) is benign. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because the variant is not currently catalogued in ClinVar.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.414856Structured0.263489Uncertain0.6160.2580.375-2.583Likely Benign0.058Likely BenignLikely Benign0.21Likely Benign0.40.65Ambiguous0.43Likely Benign0.02Likely Benign0.044Likely Benign-0.41Neutral0.000Benign0.001Benign4.16Benign0.20Tolerated0.53580.5407Strenghten112.6-16.00
c.1151G>C
G384A
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant G384A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that classify the variant as benign include REVEL, premPS, PROVEAN, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, and Rosetta. Predictions from FoldX and Foldetta are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as Likely Benign, and Foldetta as uncertain. Overall, the majority of evidence points to a benign impact, and this is consistent with the lack of ClinVar annotation. Therefore, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.728858Disordered0.427831Uncertain0.3230.9340.750-6.927Likely Benign0.112Likely BenignLikely Benign1.81Ambiguous0.22.16Destabilizing1.99Ambiguous0.04Likely Benign0.307Likely Benign-0.40Neutral0.953Possibly Damaging0.952Probably Damaging1.33Pathogenic0.05Affected0.39860.4576102.214.03
c.1195G>A
A399T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A399T is listed in ClinVar (ID 1990638.0) as Benign and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the only inconclusive results come from FoldX, Rosetta, and Foldetta, which are treated as unavailable evidence. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Benign, and Foldetta as Uncertain. Overall, the variant is most likely benign, and this conclusion aligns with its ClinVar benign classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.394753Structured0.407674Uncertain0.9390.4900.125Benign 1-5.236Likely Benign0.114Likely BenignLikely Benign1.24Ambiguous0.10.91Ambiguous1.08Ambiguous0.49Likely Benign0.272Likely Benign-0.40Neutral0.131Benign0.039Benign5.41Benign0.69Tolerated3.38260.13350.647710-2.530.03211.4-41.40.00.00.60.4XPotentially PathogenicThe methyl group of Ala399, located in an anti-parallel β sheet strand (res. Ala399-Ile411), is swapped for a hydroxyl-containing threonine. In the variant simulations, the hydroxyl group of Thr399 can form H-bonds with the backbone atoms of the residues in the membrane-facing loops (e.g., Gly382) in the C2 domain. Consequently, the ability of the Thr399 side chain to form H-bonds with the membrane-facing loops could adversely affect the dynamics and stability of the SynGAP-membrane association. However, since the effects on the dynamics of the membrane-facing loops can only be studied through the SynGAP-membrane complex, no definite conclusions can be drawn.
c.1720C>G
L574V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L574V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as likely benign, while Foldetta (combining FoldX‑MD and Rosetta outputs) yields an uncertain result. No other high‑confidence pathogenic predictions are present. Based on the preponderance of benign predictions and the lack of any ClinVar pathogenic annotation, the variant is most likely benign. This conclusion does not contradict any existing ClinVar status, as none is available.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.083462Structured0.026427Uncertain0.9270.2460.000-5.559Likely Benign0.105Likely BenignLikely Benign0.78Ambiguous0.10.37Likely Benign0.58Ambiguous0.25Likely Benign0.149Likely Benign-0.40Neutral0.004Benign0.003Benign-1.27Pathogenic0.29Tolerated0.14810.2978210.4-14.03
c.2161A>G
I721V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I721V is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Predictions that are uncertain or inconclusive are FoldX, Rosetta, Foldetta, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as benign, while Foldetta (combining FoldX‑MD and Rosetta outputs) remains uncertain. Overall, the majority of reliable predictors classify the variant as benign, and this conclusion does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.394753Structured0.454550Uncertain0.9570.4370.125-6.730Likely Benign0.380AmbiguousLikely Benign1.22Ambiguous0.01.11Ambiguous1.17Ambiguous0.48Likely Benign0.098Likely Benign-0.40Neutral0.969Probably Damaging0.960Probably Damaging2.60Benign0.45Tolerated0.09760.307043-0.3-14.03
c.2338T>G
S780A
2D
AIThe SynGAP1 missense variant S780A is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that S780A is most likely benign, and this conclusion is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.599170Disordered0.812415Binding0.2830.8830.500-5.627Likely Benign0.164Likely BenignLikely Benign0.072Likely Benign-0.40Neutral0.798Possibly Damaging0.340Benign2.69Benign0.74Tolerated0.49360.5522112.6-16.00
c.2698A>C
T900P
2D
AIThe SynGAP1 missense variant T900P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.465347Uncertain0.2890.9240.375-2.684Likely Benign0.084Likely BenignLikely Benign0.067Likely Benign-0.40Neutral0.812Possibly Damaging0.473Possibly Damaging2.67Benign0.22Tolerated0.18630.48740-1-0.9-3.99
c.2818G>T
G940C
2D
AIThe SynGAP1 missense variant G940C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. There is no ClinVar entry to contradict this conclusion, so the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.920635Binding0.3830.9020.625-8.158Likely Pathogenic0.097Likely BenignLikely Benign0.089Likely Benign-0.40Neutral0.996Probably Damaging0.905Possibly Damaging2.70Benign0.11Tolerated0.13070.4354-3-32.946.09
c.2986C>G
P996A
2D
AIThe SynGAP1 missense variant P996A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools that assess sequence conservation and structural impact uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the collective evidence strongly supports a benign classification, and this conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.775545Disordered0.942262Binding0.3120.9000.750-4.596Likely Benign0.045Likely BenignLikely Benign0.086Likely Benign-0.40Neutral0.000Benign0.002Benign4.30Benign0.86Tolerated0.32420.49611-13.4-26.04
c.298T>C
Y100H
2D
AIThe SynGAP1 missense variant Y100H is reported in gnomAD (variant ID 6-33432163‑T‑C) but has no ClinVar entry. Functional prediction tools cluster into two groups: the benign‑predicted set includes REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; the pathogenic‑predicted set contains polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments reinforce the benign classification: AlphaMissense‑Optimized predicts benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields a benign verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Overall, the consensus of available predictions indicates that Y100H is most likely benign, and this conclusion is not contradicted by any ClinVar status (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.699094Disordered0.675421Binding0.3410.8800.6256-33432163-T-C16.20e-7-2.094Likely Benign0.201Likely BenignLikely Benign0.123Likely Benign-0.40Neutral0.978Probably Damaging0.500Possibly Damaging4.23Benign0.00Affected4.3210.26500.031320-1.9-26.03
c.2992G>C
A998P
2D
AIThe SynGAP1 missense variant A998P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. Foldetta results are unavailable. Overall, the majority of evidence, including the high‑accuracy tools, points to a benign effect for A998P. This conclusion does not contradict ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.759478Disordered0.951758Binding0.3180.9020.500-2.220Likely Benign0.071Likely BenignLikely Benign0.171Likely Benign-0.40Neutral0.971Probably Damaging0.690Possibly Damaging4.31Benign0.00Affected0.19240.51061-1-3.426.04
c.3111C>G
I1037M
2D
AIThe SynGAP1 missense variant I1037M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. Only two tools, polyPhen‑2 HumDiv and polyPhen‑2 HumVar, predict a pathogenic effect. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence supports a benign classification, and this is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-3.849Likely Benign0.333Likely BenignLikely Benign0.093Likely Benign-0.40Neutral0.977Probably Damaging0.721Possibly Damaging2.71Benign0.18Tolerated0.07750.388521-2.618.03
c.3288G>C
E1096D
2D
AIThe SynGAP1 missense variant E1096D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign interpretation, and this conclusion does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.976475Binding0.3080.8581.000-3.818Likely Benign0.192Likely BenignLikely Benign0.116Likely Benign-0.40Neutral0.115Benign0.052Benign2.71Benign0.38Tolerated0.20340.4994320.0-14.03
c.3288G>T
E1096D
2D
AIThe SynGAP1 missense variant E1096D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign classification, and this conclusion is not contradicted by any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.976475Binding0.3080.8581.000-3.818Likely Benign0.192Likely BenignLikely Benign0.116Likely Benign-0.40Neutral0.115Benign0.052Benign2.71Benign0.38Tolerated0.20340.4994320.0-14.03
c.3325C>A
L1109I
2D
AIThe SynGAP1 missense variant L1109I is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign, and this conclusion is consistent with the lack of a ClinVar pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.856457Disordered0.948334Binding0.3430.8930.875-5.475Likely Benign0.073Likely BenignLikely Benign0.058Likely Benign-0.40Neutral0.126Benign0.040Benign2.70Benign0.23Tolerated0.10870.4703220.70.00
c.343C>G
Q115E
2D
AIThe SynGAP1 missense variant Q115E is reported in gnomAD (variant ID 6‑33432208‑C‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic impact. When predictions are grouped by consensus, the benign group contains seven tools, whereas the pathogenic group contains two. High‑accuracy assessments reinforce the benign view: AlphaMissense‑Optimized reports a benign outcome, and the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign effect. No Foldetta stability analysis is available, so it does not influence the overall assessment. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is assigned).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.657256Binding0.3270.8780.7506-33432208-C-G16.20e-7-3.465Likely Benign0.229Likely BenignLikely Benign0.096Likely Benign-0.40Neutral0.924Possibly Damaging0.857Possibly Damaging4.18Benign0.42Tolerated3.6150.13770.1832220.00.98
c.1100T>G
L367R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 L367R missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Those that predict a pathogenic effect are SIFT, FATHMM, and Rosetta. Tools with uncertain or inconclusive results are FoldX, premPS, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as pathogenic. Overall, the majority of evidence points to a benign impact, with a minority of pathogenic predictions. The variant’s status is not contradicted by ClinVar, as it is not yet classified there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.370445Structured0.441805Uncertain0.7900.6570.250-6.527Likely Benign0.515AmbiguousLikely Benign0.68Ambiguous0.46.63Destabilizing3.66Destabilizing0.70Ambiguous0.196Likely Benign-0.39Neutral0.146Benign0.057Benign1.66Pathogenic0.02Affected0.16080.1173-3-2-8.343.03
c.1165T>G
S389A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S389A is reported in gnomAD (ID 6‑33438070‑T‑G) and has no ClinVar entry. Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is Benign; the SGM‑Consensus is Likely Benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also reports Benign. Overall, the preponderance of evidence indicates the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.703578Disordered0.417444Uncertain0.3060.8030.8756-33438070-T-G-4.199Likely Benign0.081Likely BenignLikely Benign0.01Likely Benign0.00.37Likely Benign0.19Likely Benign0.03Likely Benign0.326Likely Benign-0.39Neutral0.140Benign0.355Benign5.08Benign0.04Affected4.3280.50370.5963Strenghten112.6-16.00
c.2596G>A
V866I
2D
AIThe SynGAP1 missense variant V866I is listed in ClinVar with an “Uncertain” status (ClinVar ID 536995.0) and is present in gnomAD (6‑33443148‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.599170Disordered0.638070Binding0.2660.7880.250Conflicting 36-33443148-G-A53.10e-6-4.652Likely Benign0.118Likely BenignLikely Benign0.059Likely Benign-0.39Neutral0.957Probably Damaging0.541Possibly Damaging2.69Benign0.27Tolerated3.8240.06990.4004430.314.03
c.2731G>C
V911L
2D
AIThe SynGAP1 missense variant V911L is not reported in ClinVar and is absent from gnomAD. Prediction tools that assess pathogenicity all converge on a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. No tool in the dataset indicates a pathogenic effect. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports a benign effect, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is classified as Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence strongly supports a benign classification, and this is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.685117Disordered0.724137Binding0.3270.9140.375-2.722Likely Benign0.166Likely BenignLikely Benign0.100Likely Benign-0.39Neutral0.451Benign0.157Benign2.73Benign0.16Tolerated0.10670.531021-0.414.03
c.293A>G
H98R
2D
AIThe SynGAP1 missense variant H98R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.631713Binding0.3480.8720.625-2.772Likely Benign0.180Likely BenignLikely Benign0.116Likely Benign-0.39Neutral0.115Benign0.006Benign4.27Benign0.00Affected0.22710.302220-1.319.05
c.3098C>G
S1033C
2D
AIThe SynGAP1 missense variant S1033C is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect for S1033C, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.910643Disordered0.993473Binding0.2940.7370.625-6.263Likely Benign0.198Likely BenignLikely Benign0.044Likely Benign-0.39Neutral0.992Probably Damaging0.750Possibly Damaging2.68Benign0.12Tolerated0.10310.57040-13.316.06
c.3292A>G
S1098G
2D
AIThe SynGAP1 missense variant S1098G is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Overall, the collective predictions strongly support a benign impact, and this conclusion is consistent with the lack of a ClinVar pathogenic classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.973030Binding0.3370.8551.000-3.494Likely Benign0.072Likely BenignLikely Benign0.066Likely Benign-0.39Neutral0.000Benign0.001Benign2.72Benign0.57Tolerated0.26340.5206100.4-30.03
c.3359G>C
G1120A
2D
AIThe SynGAP1 missense variant G1120A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; ESM1b is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign likelihood. Foldetta results are unavailable. Overall, the consensus of available predictions indicates that G1120A is most likely benign, and this conclusion does not contradict any ClinVar status because none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.871313Disordered0.804931Binding0.3350.9250.875-7.192In-Between0.082Likely BenignLikely Benign0.243Likely Benign-0.39Neutral0.264Benign0.139Benign3.64Benign0.28Tolerated0.34350.4944102.214.03
c.3371G>C
G1124A
2D
AIThe SynGAP1 missense variant G1124A is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign,” and the Foldetta stability analysis is unavailable. Taken together, the overwhelming majority of computational evidence classifies G1124A as benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.837511Disordered0.833401Binding0.3410.9310.875-6.608Likely Benign0.084Likely BenignLikely Benign0.199Likely Benign-0.39Neutral0.059Benign0.041Benign4.81Benign0.02Affected0.34940.5138102.214.03
c.475A>C
I159L
2D
AIThe SynGAP1 missense variant I159L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. ESM1b is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for I159L, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.454136Structured0.529953Binding0.2780.7310.125-7.936In-Between0.195Likely BenignLikely Benign0.128Likely Benign-0.39Neutral0.904Possibly Damaging0.847Possibly Damaging4.04Benign0.00Affected0.07760.265222-0.70.00
c.727A>G
I243V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I243V is not reported in ClinVar (ClinVar ID None) and has no entry in gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, Rosetta, premPS, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. FoldX and Foldetta give uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as likely benign, and Foldetta remains uncertain. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict ClinVar status, which currently has no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.363090Structured0.344471Uncertain0.8420.3470.000-8.237Likely Pathogenic0.314Likely BenignLikely Benign1.09Ambiguous0.10.19Likely Benign0.64Ambiguous0.39Likely Benign0.445Likely Benign-0.39Neutral0.617Possibly Damaging0.140Benign5.71Benign0.15Tolerated0.10190.259143-0.3-14.03
c.85A>G
M29V
2D
AIThe SynGAP1 missense variant M29V is reported in gnomAD (ID 6‑33423494‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic, representing the sole discordant signal. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign impact for M29V, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.541878Disordered0.438540Uncertain0.3410.8830.2506-33423494-A-G16.20e-7-1.841Likely Benign0.057Likely BenignLikely Benign0.209Likely Benign-0.39Neutral0.006Benign0.091Benign4.27Benign0.00Affected4.3210.40220.4433122.3-32.06
c.94A>T
T32S
2D
AIThe SynGAP1 missense variant T32S is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the consensus of the majority of tools and the high‑accuracy predictions point to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.437154Uncertain0.3490.8790.375-2.618Likely Benign0.072Likely BenignLikely Benign0.062Likely Benign-0.39Neutral0.171Benign0.050Benign4.18Benign0.00Affected0.36030.517411-0.1-14.03
c.95C>G
T32S
2D
AIThe SynGAP1 missense variant T32S is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the consensus of the majority of tools and the high‑accuracy predictions point to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.437154Uncertain0.3490.8790.375-2.618Likely Benign0.072Likely BenignLikely Benign0.024Likely Benign-0.39Neutral0.171Benign0.050Benign4.18Benign0.00Affected0.36030.517411-0.1-14.03
c.134A>G
N45S
2D
AIThe SynGAP1 missense variant N45S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for the variant, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.401658Structured0.431853Uncertain0.4980.7410.375-2.740Likely Benign0.217Likely BenignLikely Benign0.050Likely Benign-0.38Neutral0.458Possibly Damaging0.678Possibly Damaging4.14Benign0.00Affected0.39490.7617112.7-27.03
c.1888A>G
I630V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I630V is listed in ClinVar as Benign and is present in gnomAD (variant ID 6‑33440940‑A‑G). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome; all other tools (FoldX, Rosetta, Foldetta, premPS, ESM1b) return uncertain or inconclusive results. The high‑accuracy consensus (SGM Consensus) derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN yields a benign majority (2 benign vs. 1 pathogenic, 1 uncertain). AlphaMissense‑Optimized also predicts benign. Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, is uncertain. Taken together, the overwhelming majority of predictions support a benign effect, and this conclusion aligns with the ClinVar designation. Thus, the variant is most likely benign, with no contradiction to the ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.040537Structured0.036106Uncertain0.9660.2360.000Benign/Likely benign 46-33440940-A-G593.66e-5-7.264In-Between0.145Likely BenignLikely Benign1.33Ambiguous0.00.94Ambiguous1.14Ambiguous0.64Ambiguous0.143Likely Benign-0.38Neutral0.018Benign0.011Benign-1.37Pathogenic0.35Tolerated3.37340.09600.289143-0.3-14.03235.026.2-0.10.0-0.30.1XPotentially BenignThe sec-butyl side chain of Ile630, located in an α helix (res. Glu617-Asn635), packs with hydrophobic residues (e.g., Phe594, Leu633, Ile626, Ile602) in the hydrophobic inter-helix space between two α helices (res. Glu617-Asn635 and res. Glu582-Met603).In the variant simulations, the iso-propyl side chain of Val630, which shares a similar size and physicochemical properties with Ile630 in the WT, maintains similar interactions in the inter-helix space. Although no negative structural effects are observed during the simulations, the implications of the residue swap on the complex formation with the GTPase, due to its location, cannot be investigated using solvent-only simulations.
c.2314T>A
F772I
2D
AIThe SynGAP1 missense variant F772I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. The predictions do not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.450668Structured0.922662Binding0.3290.8840.250-2.925Likely Benign0.255Likely BenignLikely Benign0.142Likely Benign-0.38Neutral0.845Possibly Damaging0.899Possibly Damaging4.24Benign0.41Tolerated0.15440.2051101.7-34.02
c.2392C>A
P798T
2D
AIThe SynGAP1 missense variant P798T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. Foldetta results are unavailable. Overall, the majority of evidence—including the high‑accuracy tools—points to a benign effect for P798T, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.871313Disordered0.492709Uncertain0.4260.8990.875-5.926Likely Benign0.062Likely BenignLikely Benign0.039Likely Benign-0.38Neutral0.901Possibly Damaging0.534Possibly Damaging4.24Benign0.00Affected0.12930.48540-10.93.99
c.2405G>A
G802D
2D
AIThe SynGAP1 missense variant G802D is listed in ClinVar with an “Uncertain” status and is present in gnomAD (6‑33442957‑G‑A). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM—all classifying the change as benign. No tool predicts a pathogenic outcome. The high‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions points to a benign impact, which does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.894241Disordered0.681966Binding0.2940.8980.625Uncertain 16-33442957-G-A16.20e-7-5.083Likely Benign0.476AmbiguousLikely Benign0.153Likely Benign-0.38Neutral0.126Benign0.138Benign2.72Benign0.09Tolerated3.7750.19930.27421-1-3.158.04
c.2696T>G
I899S
2D
AIThe SynGAP1 missense variant I899S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic call comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign consensus. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not conflict with the ClinVar record, which contains no assertion for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.443727Uncertain0.2920.9280.375-0.857Likely Benign0.340Likely BenignLikely Benign0.082Likely Benign-0.38Neutral0.003Benign0.004Benign2.88Benign0.00Affected0.28380.0840-1-2-5.3-26.08
c.269T>A
V90E
2D
AIThe SynGAP1 missense variant V90E is listed in ClinVar (ID 971665.0) with an uncertain significance status and is not reported in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all predict benign. Only two tools—SIFT and AlphaMissense‑Default—suggest a pathogenic outcome. When the high‑accuracy consensus is considered, AlphaMissense‑Optimized remains benign, and the SGM Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign effect. No Foldetta stability assessment is available for this variant. Overall, the preponderance of evidence points to a benign impact, which does not contradict the ClinVar uncertain classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.570702Disordered0.542047Binding0.3430.8730.500Uncertain 1-4.079Likely Benign0.703Likely PathogenicLikely Benign0.108Likely Benign-0.38Neutral0.001Benign0.000Benign4.00Benign0.00Affected4.3210.13230.2233-2-2-7.729.98
c.2761C>A
L921M
2D
AIThe SynGAP1 missense variant L921M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and FATHMM. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign impact for L921M, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.608892Disordered0.943282Binding0.3110.8450.375-4.485Likely Benign0.142Likely BenignLikely Benign0.068Likely Benign-0.38Neutral0.489Possibly Damaging0.137Benign2.40Pathogenic0.02Affected0.07620.373242-1.918.03
c.278G>A
R93Q
2D
AIThe SynGAP1 missense variant R93Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta results are not available for this variant. Overall, the majority of evidence points to a benign effect; there is no conflict with ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.549151Binding0.2900.8740.625-3.938Likely Benign0.167Likely BenignLikely Benign0.074Likely Benign-0.38Neutral0.203Benign0.006Benign4.14Benign0.00Affected0.35680.2669111.0-28.06
c.2870A>T
H957L
2D
AIThe SynGAP1 missense variant H957L is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only FATHMM predicts a pathogenic outcome. When predictions are grouped by consensus, the benign group contains eight tools, whereas the pathogenic group contains only FATHMM. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a Likely Benign result. Foldetta, a protein‑folding stability method, has no available output for this variant. Overall, the preponderance of evidence indicates that H957L is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.968874Binding0.3620.9150.750-6.598Likely Benign0.090Likely BenignLikely Benign0.296Likely Benign-0.38Neutral0.000Benign0.000Benign2.44Pathogenic0.09Tolerated0.15250.5516-2-37.0-23.98
c.2892C>A
H964Q
2D
AIThe SynGAP1 missense variant H964Q is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. The only tool with an uncertain call is ESM1b, and no pathogenic predictions are reported. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments further support this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-7.279In-Between0.102Likely BenignLikely Benign0.058Likely Benign-0.38Neutral0.000Benign0.000Benign4.18Benign0.07Tolerated0.19690.359330-0.3-9.01
c.2892C>G
H964Q
2D
AIThe SynGAP1 missense variant H964Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the only uncertain result comes from ESM1b. The high‑accuracy consensus methods also support a benign classification: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the evidence overwhelmingly indicates that H964Q is most likely benign, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-7.279In-Between0.102Likely BenignLikely Benign0.058Likely Benign-0.38Neutral0.000Benign0.000Benign4.18Benign0.07Tolerated0.19690.359330-0.3-9.01
c.2914C>T
P972S
2D
AIThe SynGAP1 missense variant P972S (ClinVar ID 3361353.0) is listed as Uncertain in ClinVar and is present in gnomAD (ID 6‑33443466‑C‑T). Consensus among most in silico predictors indicates a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the substitution as benign. Only SIFT classifies it as pathogenic, representing the sole discordant prediction. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” No Foldetta stability analysis is available for this residue. Overall, the preponderance of computational evidence points to a benign effect, which is consistent with the ClinVar designation of uncertainty rather than pathogenicity.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.891961Disordered0.954150Binding0.4720.9040.625Uncertain 16-33443466-C-T42.48e-6-4.008Likely Benign0.058Likely BenignLikely Benign0.074Likely Benign-0.38Neutral0.001Benign0.002Benign4.28Benign0.05Affected4.3220.31680.4822-110.8-10.04
c.2929G>T
A977S
2D
AIThe SynGAP1 missense variant A977S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence indicates that A977S is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.975330Binding0.3060.8840.625-2.909Likely Benign0.089Likely BenignLikely Benign0.091Likely Benign-0.38Neutral0.965Probably Damaging0.702Possibly Damaging4.02Benign0.45Tolerated0.28200.537311-2.616.00
c.2999T>G
I1000S
2D
AIThe SynGAP1 missense variant I1000S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM‑Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence (seven benign vs. three pathogenic predictions) supports a benign classification. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.957020Binding0.2930.9040.625-3.694Likely Benign0.587Likely PathogenicLikely Benign0.151Likely Benign-0.38Neutral0.946Possibly Damaging0.673Possibly Damaging2.80Benign0.19Tolerated0.25010.1270-1-2-5.3-26.08
c.3035C>A
P1012H
2D
AIThe SynGAP1 missense variant P1012H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is Likely Benign. Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect for P1012H, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.894674Binding0.3190.8660.625-4.877Likely Benign0.087Likely BenignLikely Benign0.024Likely Benign-0.38Neutral0.832Possibly Damaging0.600Possibly Damaging2.75Benign0.08Tolerated0.15530.46350-2-1.640.02
c.3117T>G
I1039M
2D
AIThe SynGAP1 missense variant I1039M is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for I1039M, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.979204Binding0.2920.8060.625-3.444Likely Benign0.292Likely BenignLikely Benign0.116Likely Benign-0.38Neutral0.977Probably Damaging0.721Possibly Damaging2.68Benign0.16Tolerated0.09260.439221-2.618.03
c.32G>T
G11V
2D
AIThe SynGAP1 missense variant G11V is reported in gnomAD (variant ID 6‑33420296‑G‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. In contrast, polyPhen‑2 HumDiv and SIFT predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign. No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the preponderance of evidence from both general and high‑accuracy tools indicates that G11V is most likely benign, and this conclusion is not contradicted by any ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.444081Structured0.501027Binding0.3480.9150.3756-33420296-G-T-4.079Likely Benign0.160Likely BenignLikely Benign0.146Likely Benign-0.38Neutral0.668Possibly Damaging0.049Benign3.93Benign0.00Affected4.3210.12920.4522-3-14.642.08
c.3345T>G
I1115M
2D
AIThe SynGAP1 missense variant I1115M is reported in gnomAD (variant ID 6‑33443897‑T‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv flags it as pathogenic, creating a single discordant call. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.892339Binding0.3080.9120.7506-33443897-T-G42.77e-6-3.708Likely Benign0.067Likely BenignLikely Benign0.106Likely Benign-0.38Neutral0.512Possibly Damaging0.200Benign2.71Benign0.23Tolerated4.3220.10300.416212-2.618.03
c.3350G>A
G1117D
2D
AIThe SynGAP1 missense variant G1117D is catalogued in gnomAD (6‑33443902‑G‑A) but has no ClinVar entry. In silico predictors that agree on benign impact include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic effect, while ESM1b and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because it contains two benign and two uncertain calls, and Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar classification (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.882776Disordered0.853192Binding0.3230.9140.7506-33443902-G-A16.61e-7-7.594In-Between0.358AmbiguousLikely Benign0.315Likely Benign-0.38Neutral0.666Possibly Damaging0.355Benign4.57Benign0.24Tolerated4.3220.19200.2635-11-3.158.04
c.3703A>C
M1235L
2D
AIThe SynGAP1 missense variant M1235L is reported as “Likely Benign” by the SGM‑Consensus method and has no ClinVar entry, indicating it has not been classified in that database. It is also absent from gnomAD, so its allele frequency is not documented there. Across the spectrum of in‑silico predictors, all tools that provide a verdict—REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—concur that the substitution is benign; none predict pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized scores benign, and the SGM‑Consensus (a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates benign. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Based on the unanimous benign predictions and the lack of ClinVar classification, the variant is most likely benign, with no contradiction to existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.690604Disordered0.577958Binding0.8720.5320.125-2.013Likely Benign0.062Likely BenignLikely Benign0.067Likely Benign-0.38Neutral0.001Benign0.002Benign2.89Benign1.00Tolerated0.13630.3935421.9-18.03
c.3703A>T
M1235L
2D
AIThe SynGAP1 missense variant M1235L is reported as “Likely Benign” in the SGM‑Consensus and has no ClinVar entry, and it is not listed in gnomAD. All available in‑silico predictors classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates likely benign. Foldetta results are not available. Based on the unanimous benign predictions and lack of ClinVar or gnomAD evidence, the variant is most likely benign, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.690604Disordered0.577958Binding0.8720.5320.125-2.013Likely Benign0.062Likely BenignLikely Benign0.067Likely Benign-0.38Neutral0.001Benign0.002Benign2.89Benign1.00Tolerated0.13630.3935421.9-18.03
c.1160G>A
G387D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G387D is reported in gnomAD (6‑33438065‑G‑A) but has no ClinVar entry. Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are FoldX, Rosetta, Foldetta, SIFT, ESM1b, FATHMM, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Pathogenic. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) as pathogenic. With two of the three high‑accuracy methods indicating pathogenicity and a majority of general predictors leaning toward pathogenic, the variant is most likely pathogenic. This conclusion is not contradicted by ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicC20.642678Disordered0.422910Uncertain0.2930.8610.7506-33438065-G-A21.24e-6-8.625Likely Pathogenic0.612Likely PathogenicLikely Benign3.57Destabilizing2.33.22Destabilizing3.40Destabilizing0.39Likely Benign0.459Likely Benign-0.37Neutral0.069Benign0.041Benign1.32Pathogenic0.02Affected4.3230.21450.2035-11-3.158.04
c.133A>G
N45D
2D
AIThe SynGAP1 missense variant N45D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign; no Foldetta stability result is available. Overall, the majority of evidence—including the consensus and high‑accuracy predictions—supports a benign classification for this variant, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.401658Structured0.431853Uncertain0.4980.7410.375-3.340Likely Benign0.278Likely BenignLikely Benign0.068Likely Benign-0.37Neutral0.458Possibly Damaging0.678Possibly Damaging4.17Benign0.00Affected0.22340.4999210.00.98
c.2494C>G
Q832E
2D
AIThe SynGAP1 missense variant Q832E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv flags it as pathogenic, but this is the sole discordant call. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.720929Disordered0.619913Binding0.2900.8770.375-3.024Likely Benign0.098Likely BenignLikely Benign0.109Likely Benign-0.37Neutral0.652Possibly Damaging0.311Benign2.77Benign0.06Tolerated0.12620.1897220.00.98
c.2917G>A
G973R
2D
AIThe SynGAP1 missense variant G973R is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.959498Binding0.3900.8970.625-3.950Likely Benign0.329Likely BenignLikely Benign0.072Likely Benign-0.37Neutral0.001Benign0.003Benign4.16Benign0.01Affected0.09300.4532-3-2-4.199.14
c.2917G>C
G973R
2D
AIThe SynGAP1 missense variant G973R is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic call comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta results are not available for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.959498Binding0.3900.8970.625-3.950Likely Benign0.329Likely BenignLikely Benign0.072Likely Benign-0.37Neutral0.001Benign0.003Benign4.16Benign0.01Affected0.09300.4532-3-2-4.199.14
c.3027G>C
E1009D
2D
AIThe SynGAP1 missense variant E1009D is reported in gnomAD (ID 6‑33443579‑G‑C) but has no ClinVar entry. All in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. No tool predicts pathogenicity. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized indicates benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly supports a benign effect, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.728858Disordered0.914552Binding0.3250.8850.5006-33443579-G-C16.20e-7-2.958Likely Benign0.104Likely BenignLikely Benign0.054Likely Benign-0.37Neutral0.011Benign0.017Benign2.50Benign0.30Tolerated3.7750.20770.4817230.0-14.03
c.3027G>T
E1009D
2D
AIThe SynGAP1 missense variant E1009D is not reported in ClinVar and is absent from gnomAD. All available in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.728858Disordered0.914552Binding0.3250.8850.500-2.958Likely Benign0.104Likely BenignLikely Benign0.054Likely Benign-0.37Neutral0.011Benign0.017Benign2.50Benign0.30Tolerated3.7750.20770.4817230.0-14.03
c.303C>A
H101Q
2D
AIThe SynGAP1 missense variant H101Q is listed in ClinVar with an uncertain significance (ClinVar ID 1307533.0) and is present in gnomAD (ID 6‑33432168‑C‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote) also benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.791621Disordered0.688356Binding0.3700.8840.625Uncertain 16-33432168-C-A16.20e-7-2.827Likely Benign0.124Likely BenignLikely Benign0.147Likely Benign-0.37Neutral0.824Possibly Damaging0.880Possibly Damaging4.24Benign0.00Affected4.3210.14870.368930-0.3-9.01
c.303C>G
H101Q
2D
AIThe SynGAP1 missense variant H101Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for H101Q, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.791621Disordered0.688356Binding0.3700.8840.625-2.827Likely Benign0.124Likely BenignLikely Benign0.149Likely Benign-0.37Neutral0.824Possibly Damaging0.880Possibly Damaging4.24Benign0.00Affected4.3210.14870.368930-0.3-9.01
c.3048C>A
D1016E
2D
AIThe SynGAP1 missense variant D1016E is reported in ClinVar (ID 3803472.0) as benign and is present in gnomAD (variant ID 6‑33443600‑C‑A). All evaluated in‑silico predictors classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status is unavailable. Overall, the computational evidence overwhelmingly supports a benign effect, aligning with the ClinVar benign classification and showing no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.801317Disordered0.944705Binding0.3230.8110.625Likely Benign 16-33443600-C-A21.24e-6-3.422Likely Benign0.216Likely BenignLikely Benign0.017Likely Benign-0.37Neutral0.008Benign0.028Benign2.64Benign0.65Tolerated3.7750.22370.6898230.014.03
c.3048C>G
D1016E
2D
AIThe SynGAP1 missense variant D1016E is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign. Foldetta results are unavailable, so they do not influence the overall assessment. **Thus, the variant is most likely benign, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists.**

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.801317Disordered0.944705Binding0.3230.8110.625-3.422Likely Benign0.216Likely BenignLikely Benign0.017Likely Benign-0.37Neutral0.008Benign0.028Benign2.64Benign0.65Tolerated3.7750.22370.6898230.014.03
c.3078C>A
D1026E
2D
AIThe SynGAP1 missense variant D1026E is not reported in ClinVar and is absent from gnomAD. All available in silico predictors classify the change as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence strongly supports a benign classification, and this is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.894241Disordered0.993931Binding0.3240.7390.500-3.431Likely Benign0.190Likely BenignLikely Benign0.055Likely Benign-0.37Neutral0.001Benign0.005Benign2.73Benign0.56Tolerated0.14490.4783320.014.03
c.3078C>G
D1026E
2D
AIThe SynGAP1 missense variant D1026E is not reported in ClinVar and is absent from gnomAD. All available in silico predictors classify the change as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence strongly supports a benign classification, and this is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.894241Disordered0.993931Binding0.3240.7390.500-3.431Likely Benign0.190Likely BenignLikely Benign0.055Likely Benign-0.37Neutral0.001Benign0.005Benign2.73Benign0.56Tolerated0.14490.4783320.014.03
c.3224A>G
Q1075R
2D
AIThe SynGAP1 missense variant Q1075R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and AlphaMissense‑Default predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar status, as none is assigned to the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.988305Binding0.3540.8940.750-5.039Likely Benign0.697Likely PathogenicLikely Benign0.142Likely Benign-0.37Neutral0.985Probably Damaging0.973Probably Damaging2.72Benign0.93Tolerated0.15040.265011-1.028.06
c.3349G>A
G1117S
2D
AIThe SynGAP1 missense variant G1117S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.853192Binding0.3230.9140.750-3.890Likely Benign0.074Likely BenignLikely Benign0.211Likely Benign-0.37Neutral0.032Benign0.026Benign5.08Benign0.17Tolerated0.25720.511110-0.430.03
c.3937C>G
P1313A
2D
AIThe SynGAP1 missense variant P1313A is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool predicts pathogenicity. High‑accuracy assessments corroborate this benign classification: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions strongly suggests that P1313A is most likely benign, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.970301Binding0.4520.9020.750-3.855Likely Benign0.054Likely BenignLikely Benign0.069Likely Benign-0.37Neutral0.021Benign0.028Benign4.27Benign0.25Tolerated0.35290.58421-13.4-26.04
c.3940C>G
P1314A
2D
AIThe SynGAP1 missense variant P1314A is catalogued in gnomAD (ID 6‑33451814‑C‑G) but has no ClinVar entry. Across the spectrum of in silico predictors, every tool listed—REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—returns a benign or likely benign verdict. No pathogenic predictions appear in the dataset, so the pathogenic group is empty. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized scores benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates likely benign. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Taken together, the evidence overwhelmingly supports a benign classification, and this conclusion does not conflict with the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.971592Binding0.4670.9030.7506-33451814-C-G16.22e-7-3.540Likely Benign0.061Likely BenignLikely Benign0.043Likely Benign-0.37Neutral0.001Benign0.002Benign4.23Benign0.93Tolerated3.7750.35020.4441-113.4-26.04
c.3967C>A
P1323T
2D
AIThe SynGAP1 missense variant P1323T is reported in gnomAD (ID 6‑33451841‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as tolerated or benign. Only two algorithms—polyPhen‑2 HumDiv and SIFT—suggest a damaging impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates benign. Foldetta results are not available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not conflict with any ClinVar classification, as none is present.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.901269Disordered0.907659Binding0.4890.8140.8756-33451841-C-A-6.296Likely Benign0.073Likely BenignLikely Benign0.064Likely Benign-0.37Neutral0.588Possibly Damaging0.227Benign3.95Benign0.00Affected4.3210.19880.5161-100.93.99
c.3979C>G
P1327A
2D
AIThe SynGAP1 missense variant P1327A is reported in gnomAD (ID 6‑33451853‑C‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict the variant to be pathogenic. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this is consistent with the absence of a pathogenic ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.896620Disordered0.900145Binding0.3690.7770.8756-33451853-C-G21.28e-6-4.661Likely Benign0.089Likely BenignLikely Benign0.072Likely Benign-0.37Neutral0.980Probably Damaging0.811Possibly Damaging4.24Benign0.42Tolerated3.7750.31520.3645-113.4-26.04
c.47T>A
M16K
2D
AIThe SynGAP1 missense variant M16K is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational predictions and the high‑accuracy consensus suggest that M16K is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.440853Structured0.459925Uncertain0.3460.9080.375-2.567Likely Benign0.635Likely PathogenicLikely Benign0.185Likely Benign-0.37Neutral0.003Benign0.001Benign4.23Benign0.00Affected0.19840.11120-1-5.8-3.02
c.86T>C
M29T
2D
AIThe SynGAP1 missense variant M29T is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates that M29T is most likely benign, and this conclusion does not contradict the current ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.541878Disordered0.438540Uncertain0.3410.8830.250Uncertain 1-2.167Likely Benign0.122Likely BenignLikely Benign0.199Likely Benign-0.37Neutral0.018Benign0.184Benign4.33Benign0.00Affected4.3210.26330.2716-1-1-2.6-30.09
c.902C>G
A301G
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A301G is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only two tools, polyPhen‑2 HumDiv and HumVar, predict a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as Benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability predictions, classifies the variant as Benign. Overall, the consensus of the majority of evidence points to a benign effect, and this is consistent with the absence of a ClinVar claim. Therefore, the variant is most likely benign, and this is not contradictory to ClinVar.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.429200Structured0.258424Uncertain0.6470.2720.375-3.085Likely Benign0.072Likely BenignLikely Benign0.27Likely Benign0.10.34Likely Benign0.31Likely Benign0.37Likely Benign0.128Likely Benign-0.37Neutral0.992Probably Damaging0.983Probably Damaging4.18Benign0.28Tolerated0.24250.505410-2.2-14.03
c.20C>A
S7Y
2D
AIThe SynGAP1 missense variant S7Y is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. The predictions do not contradict any ClinVar annotation, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.590140Disordered0.548467Binding0.3860.9220.750-5.240Likely Benign0.230Likely BenignLikely Benign0.193Likely Benign-0.36Neutral0.561Possibly Damaging0.047Benign4.06Benign0.00Affected0.07080.5053-3-2-0.576.10
c.2125C>G
L709V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L709V is not reported in ClinVar and is absent from gnomAD. Across the available in‑silico predictors, every tool that produced a definitive call classifies the variant as benign: REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. No tool predicts pathogenicity. The only inconclusive results are FoldX (uncertain) and Foldetta (uncertain), which are treated as unavailable evidence. High‑accuracy assessments reinforce the benign prediction: AlphaMissense‑Optimized is benign; the SGM‑Consensus, derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is also benign; Foldetta remains uncertain. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.243554Structured0.365830Uncertain0.9340.3790.000-4.406Likely Benign0.101Likely BenignLikely Benign0.75Ambiguous0.00.42Likely Benign0.59Ambiguous0.03Likely Benign0.063Likely Benign-0.36Neutral0.062Benign0.016Benign3.42Benign0.45Tolerated0.11620.2460210.4-14.03
c.25C>A
H9N
2D
AIThe SynGAP1 missense variant H9N is reported in gnomAD (ID 6‑33420289‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is likely benign; Foldetta results are unavailable. Overall, the consensus of the available predictions points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.486429Structured0.528099Binding0.3940.9160.7506-33420289-C-A-3.789Likely Benign0.103Likely BenignLikely Benign0.081Likely Benign-0.36Neutral0.024Benign0.003Benign4.23Benign0.00Affected4.3210.23270.382312-0.3-23.04
c.2695A>C
I899L
2D
AIThe SynGAP1 missense variant I899L is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta results are not available, so they do not influence the assessment. Overall, the majority of evidence points to a benign impact, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.443727Uncertain0.2920.9280.375-1.137Likely Benign0.093Likely BenignLikely Benign0.055Likely Benign-0.36Neutral0.220Benign0.078Benign2.74Benign0.04Affected0.08630.284022-0.70.00
c.2835T>A
H945Q
2D
AIThe SynGAP1 missense variant H945Q is listed in ClinVar with an uncertain significance and is present in gnomAD (ID 6‑33443387‑T‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The high‑accuracy consensus from AlphaMissense‑Optimized is benign, and the SGM consensus—derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—is also benign. Foldetta results are not available for this variant. Overall, the majority of computational evidence points to a benign impact, which is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.750Conflicting 26-33443387-T-A31.86e-6-5.248Likely Benign0.091Likely BenignLikely Benign0.343Likely Benign-0.36Neutral0.995Probably Damaging0.939Probably Damaging5.03Benign0.06Tolerated4.3240.26710.312830-0.3-9.01
c.2835T>G
H945Q
2D
AIThe SynGAP1 missense variant H945Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. Only two tools, polyPhen‑2 HumDiv and polyPhen‑2 HumVar, predict a pathogenic effect. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for H945Q, and this conclusion is not contradicted by any ClinVar classification (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.750-5.248Likely Benign0.091Likely BenignLikely Benign0.343Likely Benign-0.36Neutral0.995Probably Damaging0.939Probably Damaging5.03Benign0.06Tolerated4.3240.26710.312830-0.3-9.01
c.2873A>C
H958P
2D
AIThe SynGAP1 missense variant H958P is listed in ClinVar as a benign alteration (ClinVar ID 1006798.0) and is present in the gnomAD database (gnomAD ID 6‑33443425‑A‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion aligns with the ClinVar benign status, showing no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.976011Binding0.3710.9130.750Benign 16-33443425-A-C21.24e-6-8.369Likely Pathogenic0.068Likely BenignLikely Benign0.204Likely Benign-0.36Neutral0.925Possibly Damaging0.316Benign4.14Benign0.10Tolerated3.7750.22900.47010-21.6-40.02
c.2906G>C
G969A
2D
AIThe SynGAP1 missense variant G969A is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity, so the pathogenic‑prediction group is empty. High‑accuracy assessments corroborate this benign consensus: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are not available, so they do not influence the interpretation. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.956572Binding0.4050.8980.750-4.693Likely Benign0.076Likely BenignLikely Benign0.120Likely Benign-0.36Neutral0.393Benign0.096Benign4.25Benign0.51Tolerated0.34140.5096102.214.03
c.2945A>T
Y982F
2D
AIThe SynGAP1 missense variant Y982F is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.966717Binding0.2720.8950.625-3.431Likely Benign0.208Likely BenignLikely Benign0.154Likely Benign-0.36Neutral0.006Benign0.009Benign4.63Benign0.00Affected0.23510.2980734.1-16.00
c.3274T>G
L1092V
2D
AIThe SynGAP1 missense variant L1092V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The high‑accuracy consensus (SGM‑Consensus) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.924947Disordered0.985431Binding0.3850.8901.000-4.906Likely Benign0.451AmbiguousLikely Benign0.034Likely Benign-0.36Neutral0.051Benign0.037Benign2.79Benign0.37Tolerated0.16580.3912210.4-14.03
c.3418A>G
T1140A
2D
AIThe SynGAP1 missense variant T1140A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.708094Binding0.2930.8541.000-3.838Likely Benign0.107Likely BenignLikely Benign0.061Likely Benign-0.36Neutral0.002Benign0.003Benign2.71Benign1.00Tolerated0.39490.3463102.5-30.03
c.3932T>G
L1311R
2D
AIThe SynGAP1 missense variant L1311R is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in‑silico predictors indicates a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the change as tolerated or benign. Only polyPhen‑2 HumDiv classifies it as pathogenic, but this is the sole discordant call. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy tools further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. Foldetta results are unavailable. Overall, the evidence overwhelmingly points to a benign impact, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.968153Binding0.3930.9070.750-3.794Likely Benign0.169Likely BenignLikely Benign0.083Likely Benign-0.36Neutral0.579Possibly Damaging0.267Benign2.74Benign0.12Tolerated0.16110.1719-3-2-8.343.03
c.5G>A
S2N
2D
AIThe SynGAP1 missense variant S2N is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33420269‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign effect, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.543646Binding0.3820.9220.750Uncertain 26-33420269-G-A31.96e-6-4.104Likely Benign0.207Likely BenignLikely Benign0.092Likely Benign-0.36Neutral0.000Benign0.000Benign4.06Benign0.00Affected4.3210.14840.563711-2.727.03
c.865A>G
M289V
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant M289V is reported in ClinVar as Benign (ClinVar ID 2122760.0) and is not present in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus all predict benign, while only FATHMM predicts pathogenic. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign; the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also indicates benign. No prediction or stability result is inconclusive. Overall, the computational evidence strongly supports a benign classification, consistent with the ClinVar status and showing no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.127496Structured0.403499Uncertain0.8860.2760.000Benign 1-4.239Likely Benign0.117Likely BenignLikely Benign1.09Ambiguous0.1-0.27Likely Benign0.41Likely Benign0.24Likely Benign0.150Likely Benign-0.36Neutral0.136Benign0.054Benign1.80Pathogenic1.00Tolerated3.38230.22800.2808212.3-32.06204.251.00.00.00.20.0XPotentially BenignThe hydrophobic residue Met289, located in a β hairpin linking two anti-parallel β sheet strands (res. Met289-Arg299, res. Arg272-Leu286), is swapped for another hydrophobic residue, valine. In the variant simulations, the branched hydrocarbon side chain of Val289 packs against the phenol group of the Tyr291 side chain but is unable to form methionine-aromatic interactions. β hairpins are potential nucleation sites during the initial stages of protein folding, so even minor changes in them could be significant. However, based on the simulations, the residue swap does not cause adverse effects on the structure.
c.14G>C
R5P
2D
AIThe SynGAP1 missense variant R5P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates that R5P is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.595080Disordered0.547847Binding0.3630.9200.750-3.438Likely Benign0.189Likely BenignLikely Benign0.286Likely Benign-0.35Neutral0.233Benign0.013Benign4.10Benign0.00Affected0.22940.55300-22.9-59.07
c.2555G>C
G852A
2D
AIThe SynGAP1 missense variant G852A is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Based on the collective predictions, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.506063Binding0.2760.8160.625-4.493Likely Benign0.068Likely BenignLikely Benign0.142Likely Benign-0.35Neutral0.393Benign0.321Benign4.25Benign1.00Tolerated0.38950.4934102.214.03
c.2848G>T
G950C
2D
AIThe SynGAP1 missense variant G950C is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. The SGM Consensus, which takes a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (2 benign vs. 2 pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of high‑confidence predictors (five pathogenic vs. four benign) indicate a pathogenic impact. This conclusion is not contradicted by ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.888649Binding0.3680.9230.750-9.589Likely Pathogenic0.092Likely BenignLikely Benign0.395Likely Benign-0.35Neutral0.983Probably Damaging0.750Possibly Damaging2.26Pathogenic0.01Affected0.14060.4439-3-32.946.09
c.2857C>T
P953S
2D
AIThe SynGAP1 missense variant P953S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this trend: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign. Foldetta results are unavailable, so they do not influence the overall assessment. **Thus, the variant is most likely benign, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists.**

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.920633Binding0.4030.9260.750-5.430Likely Benign0.061Likely BenignLikely Benign0.073Likely Benign-0.35Neutral0.009Benign0.008Benign2.96Benign0.37Tolerated0.33590.51841-10.8-10.04
c.2902G>A
G968S
2D
AIThe SynGAP1 missense variant G968S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.961360Binding0.3270.8960.750-4.484Likely Benign0.070Likely BenignLikely Benign0.124Likely Benign-0.35Neutral0.058Benign0.023Benign4.22Benign0.37Tolerated0.24820.569910-0.430.03
c.2920G>A
D974N
2D
AIThe SynGAP1 missense variant D974N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect. Consensus predictors such as SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) and high‑accuracy methods including AlphaMissense‑Optimized all classify the variant as benign. Additional in silico assessments—REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM—also predict a benign outcome. No tool in the dataset suggests pathogenicity. Protein‑stability analysis via Foldetta is unavailable for this variant. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.964377Binding0.3890.8970.625-4.051Likely Benign0.145Likely BenignLikely Benign0.088Likely Benign-0.35Neutral0.144Benign0.085Benign4.20Benign0.09Tolerated0.19720.7698210.0-0.98
c.292C>A
H98N
2D
AIThe SynGAP1 missense variant H98N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.631713Binding0.3480.8720.625-3.855Likely Benign0.070Likely BenignLikely Benign0.103Likely Benign-0.35Neutral0.115Benign0.012Benign4.24Benign0.00Affected0.20030.375921-0.3-23.04
c.3080A>G
N1027S
2D
AIThe SynGAP1 missense variant N1027S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective predictions strongly suggest that the variant is most likely benign, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.831250Disordered0.994357Binding0.3470.7450.500-2.443Likely Benign0.093Likely BenignLikely Benign0.088Likely Benign-0.35Neutral0.068Benign0.039Benign2.77Benign0.50Tolerated0.35400.6874112.7-27.03
c.3134C>T
A1045V
2D
AIThe SynGAP1 missense variant A1045V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975609Disordered0.948874Binding0.3520.8820.750-4.229Likely Benign0.076Likely BenignLikely Benign0.035Likely Benign-0.35Neutral0.011Benign0.017Benign3.06Benign1.00Tolerated0.14870.5474002.428.05
c.3853C>A
P1285T
2D
AIThe SynGAP1 missense variant P1285T is catalogued in gnomAD (ID 6‑33447901‑C‑A) but has no ClinVar entry. Across a broad panel of in silico predictors, every tool reports a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as tolerated or benign. No tool in the set predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a Likely Benign verdict. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no reported result for this variant, so its status is unavailable. Overall, the computational evidence overwhelmingly supports a benign effect, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.821643Binding0.5570.7590.7506-33447901-C-A-4.230Likely Benign0.078Likely BenignLikely Benign0.047Likely Benign-0.35Neutral0.451Benign0.193Benign4.33Benign0.40Tolerated4.3220.14960.3556-100.93.99
c.3976C>T
P1326S
2D
AIThe SynGAP1 missense variant P1326S is listed in ClinVar with no submitted interpretation and is present in gnomAD (ID 6‑33451850‑C‑T). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT predict a pathogenic impact. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence—including the high‑accuracy tools—supports a benign classification. This conclusion does not contradict the ClinVar status, which currently has no pathogenic assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.887377Binding0.3930.7820.8756-33451850-C-T-5.221Likely Benign0.121Likely BenignLikely Benign0.107Likely Benign-0.35Neutral0.999Probably Damaging0.992Probably Damaging3.74Benign0.00Affected3.7750.37220.4563-110.8-10.04
c.902C>A
A301D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A301D is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in‑silico predictors shows a predominance of benign calls: REVEL, FoldX, premPS, PROVEAN, SIFT, and FATHMM all predict benign, whereas polyPhen‑2 (HumDiv and HumVar) and ESM1b predict pathogenic. Tools with uncertain outputs—Rosetta, Foldetta, and AlphaMissense‑Default—do not provide decisive evidence. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized classifies the variant as benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also yields a benign verdict; Foldetta remains inconclusive. Taken together, the preponderance of evidence indicates that A301D is most likely benign, and this assessment does not conflict with the absence of a ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.429200Structured0.258424Uncertain0.6470.2720.375-10.276Likely Pathogenic0.488AmbiguousLikely Benign-0.37Likely Benign0.2-1.15Ambiguous-0.76Ambiguous0.23Likely Benign0.224Likely Benign-0.35Neutral0.999Probably Damaging0.995Probably Damaging4.17Benign0.07Tolerated0.15990.17050-2-5.344.01
c.1019C>G
A340G
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A340G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only FATHMM predicts a pathogenic outcome. Stability‑based methods (FoldX, Rosetta, Foldetta) are inconclusive, so they provide no evidence for or against pathogenicity. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as likely benign, and Foldetta as uncertain. Overall, the majority of reliable predictors indicate a benign effect, and there is no ClinVar annotation to contradict this assessment. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.390993Structured0.410781Uncertain0.5580.4850.250-3.763Likely Benign0.099Likely BenignLikely Benign0.66Ambiguous0.21.44Ambiguous1.05Ambiguous0.50Likely Benign0.044Likely Benign-0.34Neutral0.267Benign0.127Benign1.92Pathogenic0.42Tolerated0.23550.447010-2.2-14.03
c.11C>A
S4Y
2D
AIThe SynGAP1 missense variant S4Y is reported in gnomAD (ID 6‑33420275‑C‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; pathogenic predictions come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, indicates a likely benign effect. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus itself is benign; Foldetta results are unavailable. Taken together, the majority of evidence points to a benign impact. There is no ClinVar classification to contradict this conclusion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.608892Disordered0.547364Binding0.3900.9240.7506-33420275-C-A-5.156Likely Benign0.209Likely BenignLikely Benign0.099Likely Benign-0.34Neutral0.880Possibly Damaging0.608Possibly Damaging4.12Benign0.00Affected4.3210.07480.6181-2-3-0.576.10
c.2380C>A
P794T
2D
AIThe SynGAP1 missense variant P794T is catalogued in gnomAD (ID 6‑33442932‑C‑A) but has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool in the dataset predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields a benign prediction. The Foldetta stability analysis is not available for this variant. Overall, the consensus of all available predictions is benign, and this is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.979741Disordered0.408951Uncertain0.5500.8980.8756-33442932-C-A16.20e-7-4.838Likely Benign0.060Likely BenignLikely Benign0.046Likely Benign-0.34Neutral0.245Benign0.138Benign4.25Benign0.66Tolerated4.0730.17390.6207-100.93.99
c.2497A>C
K833Q
2D
AIThe SynGAP1 missense variant K833Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as likely benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign; Foldetta stability analysis is unavailable. Overall, the consensus of most evidence points to a benign effect, and this is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.625797Binding0.3150.8630.375-1.586Likely Benign0.215Likely BenignLikely Benign0.105Likely Benign-0.34Neutral0.999Probably Damaging0.966Probably Damaging2.62Benign0.68Tolerated0.37440.1219110.4-0.04
c.2822C>G
P941R
2D
AIThe SynGAP1 missense variant P941R is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta results are not available, so they do not influence the assessment. Overall, the majority of evidence points to a benign impact for P941R, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.874069Disordered0.900790Binding0.4030.9060.625-5.463Likely Benign0.181Likely BenignLikely Benign0.056Likely Benign-0.34Neutral0.144Benign0.062Benign2.75Benign0.01Affected0.14870.37750-2-2.959.07
c.2834A>C
H945P
2D
AIThe SynGAP1 missense variant H945P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Based on the preponderance of benign predictions and the lack of pathogenic evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.750-1.962Likely Benign0.055Likely BenignLikely Benign0.420Likely Benign-0.34Neutral0.012Benign0.047Benign5.04Benign0.05Affected0.27300.39070-21.6-40.02
c.2867C>G
S956C
2D
AIThe SynGAP1 missense variant S956C is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. The SGM Consensus, which takes a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (two benign vs. two pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of available predictions (five pathogenic vs. four benign) indicate a likely pathogenic impact. This conclusion is not contradicted by ClinVar status, as the variant has no existing ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.984871Disordered0.957345Binding0.3640.9170.750-9.292Likely Pathogenic0.108Likely BenignLikely Benign0.107Likely Benign-0.34Neutral0.938Possibly Damaging0.665Possibly Damaging1.94Pathogenic0.03Affected0.18330.54700-13.316.06
c.2891A>C
H964P
2D
AIThe SynGAP1 missense variant H964P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign, while the only pathogenic call comes from SIFT. ESM1b is uncertain, and the SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign consensus. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates likely benign. Foldetta stability analysis is unavailable. Overall, the collective evidence points to a benign impact for H964P, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-7.466In-Between0.063Likely BenignLikely Benign0.156Likely Benign-0.34Neutral0.000Benign0.000Benign4.12Benign0.04Affected0.19780.43010-21.6-40.02
c.2998A>C
I1000L
2D
AIThe SynGAP1 missense variant I1000L is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.957020Binding0.2930.9040.625-2.103Likely Benign0.117Likely BenignLikely Benign0.083Likely Benign-0.34Neutral0.211Benign0.108Benign2.76Benign0.70Tolerated0.09160.403422-0.70.00
c.3182G>C
G1061A
2D
AIThe SynGAP1 missense variant G1061A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.926729Binding0.3940.9230.875-6.328Likely Benign0.082Likely BenignLikely Benign0.244Likely Benign-0.34Neutral0.004Benign0.002Benign4.01Benign0.00Affected0.32890.5133102.214.03
c.3184G>A
G1062R
2D
AIThe SynGAP1 missense variant G1062R is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443736‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, polyPhen‑2 HumVar, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, while Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.936972Binding0.3680.9170.875Conflicting 26-33443736-G-A74.35e-6-6.933Likely Benign0.353AmbiguousLikely Benign0.403Likely Benign-0.34Neutral0.797Possibly Damaging0.139Benign4.10Benign0.01Affected4.3220.10130.4342-3-2-4.199.14
c.3184G>C
G1062R
2D
AIThe SynGAP1 missense variant G1062R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicating a likely benign outcome, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.936972Binding0.3680.9170.875-6.933Likely Benign0.353AmbiguousLikely Benign0.413Likely Benign-0.34Neutral0.797Possibly Damaging0.139Benign4.10Benign0.01Affected4.3220.10130.4342-3-2-4.199.14
c.3361A>C
S1121R
2D
AIThe SynGAP1 missense variant S1121R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign, reflecting the majority of benign predictions. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact for S1121R, and this conclusion is consistent with the lack of ClinVar reporting.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.894241Disordered0.810024Binding0.3650.9350.875-6.945Likely Benign0.597Likely PathogenicLikely Benign0.142Likely Benign-0.34Neutral0.016Benign0.015Benign5.45Benign0.00Affected3.7750.13460.3431-10-3.769.11
c.3363C>A
S1121R
2D
AIThe SynGAP1 missense variant S1121R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.894241Disordered0.810024Binding0.3650.9350.875-6.945Likely Benign0.597Likely PathogenicLikely Benign0.100Likely Benign-0.34Neutral0.016Benign0.015Benign5.45Benign0.00Affected3.7750.13460.3431-10-3.769.11
c.3363C>G
S1121R
2D
AIThe SynGAP1 missense variant S1121R is catalogued in gnomAD (ID 6‑33443915‑C‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all report benign. Only SIFT and AlphaMissense‑Default predict pathogenicity, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.894241Disordered0.810024Binding0.3650.9350.8756-33443915-C-G-6.945Likely Benign0.597Likely PathogenicLikely Benign0.101Likely Benign-0.34Neutral0.016Benign0.015Benign5.45Benign0.00Affected3.7750.13460.3431-10-3.769.11
c.338G>A
G113E
2D
AIThe SynGAP1 missense variant G113E is not reported in ClinVar (ClinVar ID: None) but is present in gnomAD (ID 6‑33432203‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote) also as benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.639486Binding0.3500.8700.7506-33432203-G-A16.20e-7-3.169Likely Benign0.669Likely PathogenicLikely Benign0.092Likely Benign-0.34Neutral0.028Benign0.006Benign4.21Benign0.05Affected3.6150.14640.4035-20-3.172.06
c.3401C>A
T1134N
2D
AIThe SynGAP1 missense variant T1134N is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that T1134N is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.885302Disordered0.813034Binding0.3350.8850.875-4.368Likely Benign0.176Likely BenignLikely Benign0.193Likely Benign-0.34Neutral0.001Benign0.001Benign5.42Benign0.04Affected0.13860.487000-2.813.00
c.49T>G
S17A
2D
AIThe SynGAP1 missense variant S17A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. Foldetta results are unavailable. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.483068Structured0.452228Uncertain0.3410.9100.375-3.140Likely Benign0.166Likely BenignLikely Benign0.078Likely Benign-0.34Neutral0.000Benign0.000Benign4.15Benign0.00Affected0.52760.5824Strenghten112.6-16.00
c.1019C>A
A340E
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant A340E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, and polyPhen‑2 HumVar. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, ESM1b, FATHMM, and AlphaMissense‑Default. Predictions that are inconclusive or unavailable are FoldX, Rosetta, Foldetta, and AlphaMissense‑Optimized. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports a likely pathogenic outcome, while the protein‑folding stability method Foldetta is uncertain. AlphaMissense‑Optimized also yields an uncertain result. Overall, the majority of evidence points toward a pathogenic impact, and this is consistent with the lack of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicC20.390993Structured0.410781Uncertain0.5580.4850.250-8.225Likely Pathogenic0.803Likely PathogenicAmbiguous0.63Ambiguous0.41.55Ambiguous1.09Ambiguous0.06Likely Benign0.138Likely Benign-0.33Neutral0.625Possibly Damaging0.252Benign1.91Pathogenic0.39Tolerated0.14180.21600-1-5.358.04
c.10T>C
S4P
2D
AIThe SynGAP1 missense variant S4P is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools largely support a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. In contrast, two tools—polyPhen‑2 HumDiv and SIFT—predict a pathogenic impact. High‑accuracy methods give a consistent benign signal: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.608892Disordered0.547364Binding0.3900.9240.750-4.131Likely Benign0.114Likely BenignLikely Benign0.153Likely Benign-0.33Neutral0.676Possibly Damaging0.307Benign4.12Benign0.00Affected0.20430.61121-1-0.810.04
c.2221C>G
P741A
2D
AIThe SynGAP1 missense variant P741A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign,” while Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.885302Disordered0.493550Uncertain0.3540.8590.875-3.995Likely Benign0.054Likely BenignLikely Benign0.094Likely Benign-0.33Neutral0.425Benign0.136Benign3.01Benign0.98Tolerated0.29420.38831-13.4-26.04
c.2227C>T
P743S
2D
AIThe SynGAP1 missense variant P743S is listed in gnomAD (ID 6‑33441692‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all classify the change as benign. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support benignity: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is “Likely Benign.” No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence indicates that P743S is most likely benign, and this conclusion is not contradicted by any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.526809Binding0.3170.8620.8756-33441692-C-T16.19e-7-4.286Likely Benign0.063Likely BenignLikely Benign0.085Likely Benign-0.33Neutral0.021Benign0.015Benign2.93Benign0.00Affected4.3220.30870.3948-110.8-10.0410.1016/j.ajhg.2020.11.011
c.2389C>G
P797A
2D
AIThe SynGAP1 missense variant P797A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign. Foldetta results are not available, so they do not influence the assessment. Overall, the majority of evidence indicates that P797A is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.926919Disordered0.449970Uncertain0.5610.9020.875-5.548Likely Benign0.050Likely BenignLikely Benign0.037Likely Benign-0.33Neutral0.649Possibly Damaging0.535Possibly Damaging4.25Benign0.54Tolerated0.37040.48321-13.4-26.04
c.2605C>G
L869V
2D
AIThe SynGAP1 missense variant L869V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.501700Disordered0.688653Binding0.2720.8390.250-3.241Likely Benign0.161Likely BenignLikely Benign0.093Likely Benign-0.33Neutral0.481Possibly Damaging0.300Benign2.86Benign0.11Tolerated0.15010.3616210.4-14.03
c.2638G>T
A880S
2D
AIThe SynGAP1 missense variant A880S is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.621441Binding0.3090.8740.250-3.149Likely Benign0.076Likely BenignLikely Benign0.092Likely Benign-0.33Neutral0.393Benign0.187Benign2.63Benign0.10Tolerated0.25040.510811-2.616.00
c.2692T>A
S898T
2D
AIThe SynGAP1 missense variant S898T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.690604Disordered0.426070Uncertain0.3050.9220.500-4.910Likely Benign0.166Likely BenignLikely Benign0.097Likely Benign-0.33Neutral0.992Probably Damaging0.814Possibly Damaging2.50Benign0.78Tolerated0.18330.6209110.114.03
c.2710A>G
M904V
2D
AIThe SynGAP1 missense variant M904V is reported in ClinVar (ID 833650.0) as benign and is present in gnomAD (variant ID 6‑33443262‑A‑G). All evaluated in‑silico predictors classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the computational evidence strongly supports a benign classification, which aligns with the ClinVar status and shows no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.589073Binding0.3500.9200.250Likely Benign 26-33443262-A-G774.78e-5-2.907Likely Benign0.112Likely BenignLikely Benign0.058Likely Benign-0.33Neutral0.039Benign0.023Benign2.80Benign0.10Tolerated3.7750.37240.3948212.3-32.06
c.2851C>G
H951D
2D
AIThe SynGAP1 missense variant H951D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated methods. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on current predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-5.901Likely Benign0.188Likely BenignLikely Benign0.186Likely Benign-0.33Neutral0.000Benign0.001Benign5.43Benign0.46Tolerated0.28510.24751-1-0.3-22.05
c.2855G>T
G952V
2D
AIThe SynGAP1 missense variant G952V is listed in ClinVar (ID 2055482.0) with an “Uncertain” status and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while ESM1b remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as “Likely Benign.” High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates that G952V is most likely benign, and this conclusion does not contradict the current ClinVar status of uncertainty.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.910621Binding0.3410.9260.750Uncertain 1-7.074In-Between0.078Likely BenignLikely Benign0.231Likely Benign-0.33Neutral0.000Benign0.000Benign3.20Benign0.02Affected3.7750.15380.3507-1-34.642.08
c.2903G>C
G968A
2D
AIThe SynGAP1 missense variant G968A is predicted to be benign by all available in‑silico tools. Consensus predictors (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized) and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all classify the change as benign. No tools predict pathogenicity, so the pathogenic group is empty. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized reports benign, and the SGM‑Consensus indicates “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Based on the unanimous benign predictions and the absence of ClinVar evidence, the variant is most likely benign and does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.961360Binding0.3270.8960.750-4.721Likely Benign0.070Likely BenignLikely Benign0.076Likely Benign-0.33Neutral0.245Benign0.140Benign4.24Benign0.68Tolerated0.34010.5154102.214.03
c.3173G>A
G1058D
2D
AIThe SynGAP1 missense variant G1058D is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33443725‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict ClinVar, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.980739Disordered0.885724Binding0.4070.9290.8756-33443725-G-A16.21e-7-10.344Likely Pathogenic0.391AmbiguousLikely Benign0.177Likely Benign-0.33Neutral0.077Benign0.042Benign5.20Benign0.01Affected3.7750.18890.2435-11-3.158.04
c.3311C>T
P1104L
2D
AIThe SynGAP1 missense variant P1104L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only polyPhen‑2 HumDiv indicates a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also predicts Likely Benign; Foldetta results are unavailable. Overall, the consensus of the majority of tools, including the high‑accuracy predictors, points to a benign impact. This conclusion is consistent with the lack of ClinVar evidence and does not contradict any existing database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.936162Disordered0.954801Binding0.4400.8630.875-3.846Likely Benign0.096Likely BenignLikely Benign0.146Likely Benign-0.33Neutral0.626Possibly Damaging0.168Benign2.81Benign1.00Tolerated0.22640.6795-3-35.416.04
c.3347G>A
G1116E
2D
AIThe SynGAP1 missense variant G1116E is reported in gnomAD (variant ID 6-33443899‑G‑A) but has no ClinVar entry. Functional prediction tools uniformly favor a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while AlphaMissense‑Default remains uncertain. No tool predicts pathogenicity. The high‑accuracy consensus (SGM‑Consensus) also indicates a likely benign outcome, and AlphaMissense‑Optimized corroborates this. Foldetta, a protein‑folding stability predictor, was not available for this variant. Overall, the collective evidence strongly supports a benign impact, and this conclusion is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.873279Binding0.3200.9090.7506-33443899-G-A-6.375Likely Benign0.375AmbiguousLikely Benign0.345Likely Benign-0.33Neutral0.043Benign0.022Benign4.06Benign0.07Tolerated4.3220.14670.4069-20-3.172.06
c.3356G>C
G1119A
2D
AIThe SynGAP1 missense variant G1119A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.827927Disordered0.818538Binding0.3390.9280.875-6.703Likely Benign0.082Likely BenignLikely Benign0.201Likely Benign-0.33Neutral0.393Benign0.187Benign3.93Benign1.00Tolerated0.35910.4957102.214.03
c.358G>C
G120R
2D
AIThe SynGAP1 missense variant G120R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. Only AlphaMissense‑Default predicts a pathogenic outcome. When predictions are grouped, the benign consensus includes eight tools, whereas the pathogenic consensus contains a single tool. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports a benign effect, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields a likely benign classification. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that G120R is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.659993Binding0.3590.8870.750-4.406Likely Benign0.745Likely PathogenicLikely Benign0.022Likely Benign-0.33Neutral0.089Benign0.047Benign4.26Benign0.14Tolerated0.10500.4345-3-2-4.199.14
c.3961C>G
P1321A
2D
AIThe SynGAP1 missense variant P1321A is reported in gnomAD (ID 6‑33451835‑C‑G) and has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.827927Disordered0.933505Binding0.4630.8280.8756-33451835-C-G-4.411Likely Benign0.051Likely BenignLikely Benign0.058Likely Benign-0.33Neutral0.001Benign0.000Benign4.29Benign0.42Tolerated3.7750.36150.4716-113.4-26.04
c.3974C>G
P1325R
2D
AIThe SynGAP1 missense variant P1325R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and there is no conflict with ClinVar status, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.893621Binding0.4390.7910.875-5.427Likely Benign0.173Likely BenignLikely Benign0.051Likely Benign-0.33Neutral0.182Benign0.029Benign4.06Benign0.00Affected0.16680.30810-2-2.959.07
c.46A>C
M16L
2D
AIThe SynGAP1 missense variant M16L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is provided).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.440853Structured0.459925Uncertain0.3460.9080.375-1.277Likely Benign0.249Likely BenignLikely Benign0.075Likely Benign-0.33Neutral0.001Benign0.000Benign4.37Benign0.00Affected0.18050.4629421.9-18.03
c.46A>T
M16L
2D
AIThe SynGAP1 missense variant M16L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.440853Structured0.459925Uncertain0.3460.9080.375-1.277Likely Benign0.249Likely BenignLikely Benign0.075Likely Benign-0.33Neutral0.001Benign0.000Benign4.37Benign0.00Affected0.18050.4629421.9-18.03
c.727A>C
I243L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 I243L missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the only inconclusive results come from AlphaMissense‑Default and ESM1b, which are treated as unavailable. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields benign; and Foldetta also predicts benign. Overall, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
PH0.363090Structured0.344471Uncertain0.8420.3470.000-7.890In-Between0.524AmbiguousLikely Benign-0.03Likely Benign0.2-0.35Likely Benign-0.19Likely Benign0.32Likely Benign0.380Likely Benign-0.33Neutral0.048Benign0.039Benign5.74Benign0.19Tolerated0.06260.289122-0.70.00
c.103G>A
V35I
2D
AIThe SynGAP1 missense variant V35I is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33423512‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a benign outcome. No Foldetta stability data are available. Overall, the majority of evidence points to a benign impact, and this is consistent with the ClinVar “Uncertain” classification rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.613573Disordered0.434838Uncertain0.3600.8510.375Uncertain 16-33423512-G-A53.10e-6-3.764Likely Benign0.081Likely BenignLikely Benign0.017Likely Benign-0.32Neutral0.672Possibly Damaging0.369Benign4.16Benign0.00Affected4.3210.08390.3757340.314.03
c.1115G>C
G372A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G372A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, AlphaMissense‑Default, AlphaMissense‑Optimized, and ESM1b. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as uncertain. FoldX and Rosetta individually also return uncertain results. Overall, the majority of evidence points to a benign impact for G372A, and this conclusion does not contradict any ClinVar status, as the variant is not yet catalogued in ClinVar.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.433034Structured0.430335Uncertain0.3220.7740.375-5.163Likely Benign0.087Likely BenignLikely Benign1.52Ambiguous0.21.58Ambiguous1.55Ambiguous-0.12Likely Benign0.465Likely Benign-0.32Neutral0.000Benign0.000Benign-0.74Pathogenic0.03Affected0.39560.5247102.214.03
c.1129A>C
M377L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M377L is catalogued in gnomAD (ID 6‑33438034‑A‑C) but has no entry in ClinVar. Functional prediction tools largely agree on a benign effect: REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign. Only Rosetta yields an uncertain result, which is treated as unavailable. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates benign; and Foldetta, which integrates FoldX‑MD and Rosetta outputs, reports benign. No tool predicts pathogenicity. Consequently, the variant is most likely benign, and this conclusion is not contradicted by ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.675549Disordered0.431183Uncertain0.3240.8840.6256-33438034-A-C11.95e-6-2.394Likely Benign0.082Likely BenignLikely Benign0.13Likely Benign0.10.69Ambiguous0.41Likely Benign0.16Likely Benign0.175Likely Benign-0.32Neutral0.000Benign0.001Benign5.46Benign0.58Tolerated4.32120.25160.4885241.9-18.03
c.1129A>T
M377L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M377L is reported in gnomAD (variant ID 6‑33438034‑A‑T) but has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and SGM‑Consensus all classify the change as benign or likely benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, reports a benign effect. No inconclusive or missing predictions are present. Based on the collective evidence, the variant is most likely benign, and this assessment is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.675549Disordered0.431183Uncertain0.3240.8840.6256-33438034-A-T-2.394Likely Benign0.082Likely BenignLikely Benign0.13Likely Benign0.10.69Ambiguous0.41Likely Benign0.16Likely Benign0.186Likely Benign-0.32Neutral0.000Benign0.001Benign5.46Benign0.58Tolerated4.32120.25160.4885241.9-18.03
c.205A>C
I69L
2D
AIThe SynGAP1 missense variant I69L is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic call comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates benign; Foldetta results are not available. Overall, the majority of evidence supports a benign impact for I69L, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.575842Disordered0.466129Uncertain0.4370.7860.375-2.065Likely Benign0.074Likely BenignLikely Benign0.067Likely Benign-0.32Neutral0.267Benign0.141Benign4.27Benign0.00Affected0.06360.344722-0.70.00
c.2098C>A
L700M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L700M is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only Rosetta predicts a pathogenic outcome, while Foldetta’s stability assessment is uncertain. The high‑accuracy consensus (SGM Consensus) is derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, all of which are benign, yielding a “Likely Benign” classification. AlphaMissense‑Optimized also predicts benign, whereas Foldetta remains inconclusive. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.113710Structured0.416255Uncertain0.9270.3310.000-4.617Likely Benign0.139Likely BenignLikely Benign0.11Likely Benign0.02.79Destabilizing1.45Ambiguous0.35Likely Benign0.039Likely Benign-0.32Neutral0.211Benign0.081Benign3.29Benign0.08Tolerated0.07330.239742-1.918.03
c.2663C>G
A888G
2D
AIThe SynGAP1 missense variant A888G is reported in gnomAD (ID 6‑33443215‑C‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic, representing a single dissenting opinion. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.575860Binding0.3520.9280.6256-33443215-C-G53.10e-6-2.523Likely Benign0.073Likely BenignLikely Benign0.047Likely Benign-0.32Neutral0.033Benign0.036Benign2.69Benign0.00Affected4.3240.23120.520701-2.2-14.0310.1016/j.ajhg.2020.11.011
c.2731G>A
V911I
2D
AIThe SynGAP1 missense variant V911I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign,” while Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.685117Disordered0.724137Binding0.3270.9140.375-3.983Likely Benign0.085Likely BenignLikely Benign0.024Likely Benign-0.32Neutral0.451Benign0.209Benign2.70Benign0.22Tolerated0.08810.4331430.314.03
c.278G>C
R93P
2D
AIThe SynGAP1 missense variant R93P is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus indicates Likely Benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.549151Binding0.2900.8740.625-3.164Likely Benign0.473AmbiguousLikely Benign0.121Likely Benign-0.32Neutral0.361Benign0.038Benign3.99Benign0.00Affected0.22000.48440-22.9-59.07
c.2881C>A
H961N
2D
AIThe SynGAP1 missense variant H961N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as likely benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that H961N is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750-8.561Likely Pathogenic0.096Likely BenignLikely Benign0.084Likely Benign-0.32Neutral0.069Benign0.036Benign4.17Benign0.81Tolerated0.20740.369521-0.3-23.04
c.289G>C
E97Q
2D
AIThe SynGAP1 missense variant E97Q is reported in gnomAD (ID 6‑33425897‑G‑C) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus itself is Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence from both consensus and high‑accuracy predictors indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.609018Binding0.3400.8670.6256-33425897-G-C21.24e-6-3.917Likely Benign0.300Likely BenignLikely Benign0.113Likely Benign-0.32Neutral0.978Probably Damaging0.832Possibly Damaging4.13Benign0.00Affected4.3210.15070.7874220.0-0.98
c.3000C>G
I1000M
2D
AIThe SynGAP1 missense variant I1000M is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.957020Binding0.2930.9040.625-3.541Likely Benign0.161Likely BenignLikely Benign0.035Likely Benign-0.32Neutral0.437Benign0.108Benign2.70Benign0.17Tolerated0.07690.310421-2.618.03
c.3190C>A
Q1064K
2D
AIThe SynGAP1 missense variant Q1064K is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective predictions strongly support a benign classification, and this conclusion is consistent with the lack of any ClinVar pathogenic annotation, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875-3.592Likely Benign0.234Likely BenignLikely Benign0.088Likely Benign-0.32Neutral0.224Benign0.120Benign4.23Benign0.24Tolerated0.27580.419211-0.40.04
c.3367G>A
G1123S
2D
AIThe SynGAP1 missense variant G1123S is reported in gnomAD (variant ID 6-33443919-G-A) but has no ClinVar entry. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.837511Disordered0.827246Binding0.3460.9340.8756-33443919-G-A-4.918Likely Benign0.077Likely BenignLikely Benign0.291Likely Benign-0.32Neutral0.292Benign0.157Benign4.66Benign0.57Tolerated3.7750.25540.511101-0.430.03
c.3374G>A
G1125E
2D
AIThe SynGAP1 missense variant G1125E is not reported in ClinVar (ClinVar status: not reported) but is present in gnomAD (gnomAD ID 6‑33443926‑G‑A). Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, SIFT, AlphaMissense‑Optimized, and FATHMM, while pathogenic predictions arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b; AlphaMissense‑Default remains uncertain. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, favors a benign outcome (2 benign vs. 1 pathogenic). High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM Consensus as benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.834292Disordered0.835839Binding0.3390.9230.8756-33443926-G-A117.34e-6-9.849Likely Pathogenic0.353AmbiguousLikely Benign0.264Likely Benign-0.32Neutral1.000Probably Damaging0.999Probably Damaging4.58Benign0.09Tolerated3.7750.14300.4063-20-3.172.06
c.3682G>C
E1228Q
2D
AIThe SynGAP1 missense variant E1228Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized indicates a benign effect, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports a likely benign outcome. Foldetta results are not available, so they do not influence the assessment. Overall, the computational evidence overwhelmingly supports a benign interpretation, and this is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.517562Disordered0.447051Uncertain0.8920.5460.500-2.675Likely Benign0.161Likely BenignLikely Benign0.088Likely Benign-0.32Neutral0.287Benign0.112Benign2.69Benign0.25Tolerated0.08300.3797220.0-0.98
c.3791G>C
G1264A
2D
AIThe SynGAP1 missense variant G1264A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only polyPhen‑2 HumDiv indicates a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign likelihood. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the lack of any ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.429200Structured0.762385Binding0.8970.5790.000-3.460Likely Benign0.179Likely BenignLikely Benign0.069Likely Benign-0.32Neutral0.454Possibly Damaging0.192Benign2.79Benign0.91Tolerated0.35040.4220102.214.03
c.389A>G
Q130R
2D
AIThe SynGAP1 missense variant Q130R is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions come from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, indicates a likely benign effect. High‑accuracy assessments further support this: AlphaMissense‑Optimized classifies the variant as benign, and the SGM‑Consensus also reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from both general and high‑accuracy predictors points to a benign impact. This conclusion is consistent with the absence of a ClinVar assertion, so there is no contradiction with existing clinical database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.509769Disordered0.718853Binding0.3060.8850.375-4.043Likely Benign0.478AmbiguousLikely Benign0.166Likely Benign-0.32Neutral0.967Probably Damaging0.901Possibly Damaging4.21Benign0.05Affected0.16970.234311-1.028.06
c.461G>C
S154T
2D
AIThe SynGAP1 missense variant S154T is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of tools, including the high‑accuracy methods, indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.505461Disordered0.508330Binding0.2840.7950.500-5.313Likely Benign0.155Likely BenignLikely Benign0.167Likely Benign-0.32Neutral0.900Possibly Damaging0.434Benign4.13Benign0.99Tolerated0.16860.5099110.114.03
c.842A>T
Y281F
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Y281F is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, Rosetta, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM predict pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, indicates a likely benign outcome. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts benign; Foldetta, which integrates FoldX‑MD and Rosetta outputs, also predicts benign. No evidence from the uncertain FoldX result is considered. Overall, the consensus of high‑confidence tools points to a benign classification, which is consistent with the absence of ClinVar evidence and gnomAD data. Thus, the variant is most likely benign, and this conclusion does not contradict ClinVar status, which has no reported pathogenicity.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.098513Structured0.337647Uncertain0.9270.2540.000-3.991Likely Benign0.146Likely BenignLikely Benign0.75Ambiguous0.2-0.26Likely Benign0.25Likely Benign-0.37Likely Benign0.372Likely Benign-0.32Neutral0.999Probably Damaging0.992Probably Damaging1.17Pathogenic0.54Tolerated0.23800.3885734.1-16.00
c.1112G>A
S371N
2D
AIThe SynGAP1 missense variant S371N is not reported in ClinVar and is absent from gnomAD. Prediction tools that uniformly indicate a benign effect include REVEL, FoldX, Foldetta, premPS, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while Rosetta remains uncertain. High‑accuracy assessments are consistent: AlphaMissense‑Optimized classifies the variant as benign; the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports Likely Benign; and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts a benign effect. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.444081Structured0.432086Uncertain0.2940.7460.375-5.950Likely Benign0.160Likely BenignLikely Benign0.21Likely Benign0.8-0.59Ambiguous-0.19Likely Benign0.25Likely Benign0.208Likely Benign-0.31Neutral0.666Possibly Damaging0.067Benign4.64Benign0.27Tolerated0.20680.510011-2.727.03
c.1129A>G
M377V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M377V is not reported in ClinVar (ClinVar ID None) but is present in gnomAD (gnomAD ID 6‑33438034‑A‑G). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the only inconclusive results come from FoldX, Rosetta, and Foldetta, which are treated as unavailable. High‑accuracy assessments confirm the benign prediction: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is benign, while Foldetta remains uncertain. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.675549Disordered0.431183Uncertain0.3240.8840.6256-33438034-A-G-1.507Likely Benign0.073Likely BenignLikely Benign0.92Ambiguous0.31.27Ambiguous1.10Ambiguous0.48Likely Benign0.161Likely Benign-0.31Neutral0.000Benign0.000Benign5.46Benign0.15Tolerated4.32120.45300.4096122.3-32.06
c.1153T>A
S385T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S385T is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 HumDiv, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumVar and SIFT predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments—AlphaMissense‑Optimized, the SGM‑Consensus, and Foldetta (combining FoldX‑MD and Rosetta outputs)—all indicate a benign effect. Consequently, the variant is most likely benign based on the available predictions, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.733139Disordered0.425480Uncertain0.3410.9250.750-5.904Likely Benign0.095Likely BenignLikely Benign0.65Ambiguous0.20.05Likely Benign0.35Likely Benign-0.12Likely Benign0.214Likely Benign-0.31Neutral0.140Benign0.481Possibly Damaging4.64Benign0.03Affected0.22660.6259110.114.03
c.1586T>A
I529N
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I529N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign) all predict a neutral impact. In contrast, polyPhen‑2 (HumDiv and HumVar) and FATHMM predict a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores the variant as benign; the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates Likely Benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, predicts a benign effect. Taken together, the preponderance of evidence from both general and high‑accuracy predictors indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.318242Structured0.019545Uncertain0.9010.4030.000-4.478Likely Benign0.283Likely BenignLikely Benign0.12Likely Benign0.2-0.05Likely Benign0.04Likely Benign0.46Likely Benign0.378Likely Benign-0.31Neutral0.997Probably Damaging0.952Probably Damaging-1.24Pathogenic0.20Tolerated0.07220.0700-2-3-8.00.94
c.199C>G
L67V
2D
AIThe SynGAP1 missense variant L67V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. In contrast, polyPhen‑2 HumDiv and SIFT predict pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for the L67V substitution, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.458154Structured0.473668Uncertain0.4280.7610.125-3.617Likely Benign0.285Likely BenignLikely Benign0.122Likely Benign-0.31Neutral0.458Possibly Damaging0.364Benign4.15Benign0.00Affected0.11380.2817210.4-14.03
c.236A>G
N79S
2D
AIThe SynGAP1 missense variant N79S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.618285Disordered0.457064Uncertain0.2900.8760.375-2.311Likely Benign0.079Likely BenignLikely Benign0.017Likely Benign-0.31Neutral0.113Benign0.011Benign4.29Benign0.00Affected0.31550.4740112.7-27.03
c.2381C>A
P794Q
2D
AIThe SynGAP1 missense variant P794Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect for P794Q, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.979741Disordered0.408951Uncertain0.5500.8980.875-4.641Likely Benign0.101Likely BenignLikely Benign0.058Likely Benign-0.31Neutral0.918Possibly Damaging0.601Possibly Damaging4.24Benign0.02Affected0.15810.49710-1-1.931.01
c.2386C>G
P796A
2D
AIThe SynGAP1 missense variant P796A is not reported in ClinVar (ClinVar ID: None) but is present in gnomAD (gnomAD ID: 6‑33442938‑C‑G). All evaluated in silico predictors classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized return benign or benign‑like scores. No tool predicts pathogenicity. Grouping by agreement, the benign‑predicting tools comprise the entire set, while no pathogenic predictions are available. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta, a protein‑folding stability method, did not provide a result for this variant. Overall, the computational evidence strongly suggests that P796A is most likely benign, and this conclusion does not contradict the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.936162Disordered0.426363Uncertain0.4270.9000.8756-33442938-C-G-6.077Likely Benign0.050Likely BenignLikely Benign0.023Likely Benign-0.31Neutral0.174Benign0.063Benign4.28Benign0.08Tolerated4.3220.35980.3776-113.4-26.04
c.256G>A
V86I
2D
AIThe SynGAP1 missense variant V86I is listed in ClinVar (ID 588267.0) with an “Uncertain” status and is not reported in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all classify the variant as benign or likely benign. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is “Likely Benign.” No Foldetta (FoldX‑MD/Rosetta stability) result is available, so it does not influence the assessment. Overall, the majority of predictions indicate that V86I is most likely benign, which is consistent with the ClinVar “Uncertain” classification rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.685117Disordered0.552911Binding0.2950.8870.500Uncertain 1-4.726Likely Benign0.338Likely BenignLikely Benign0.076Likely Benign-0.31Neutral0.267Benign0.097Benign3.94Benign0.00Affected4.3210.08870.4417430.314.03
c.2570G>C
S857T
2D
AIThe SynGAP1 missense variant S857T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta results are unavailable, so they do not influence the overall assessment. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.728858Disordered0.475747Uncertain0.2880.8260.375-4.840Likely Benign0.076Likely BenignLikely Benign0.142Likely Benign-0.31Neutral0.979Probably Damaging0.973Probably Damaging4.09Benign0.33Tolerated0.16450.6733110.114.03
c.2641T>A
L881M
2D
AIThe SynGAP1 missense variant L881M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are not available. Overall, the majority of predictions (six benign vs. four pathogenic) lean toward a benign interpretation. Thus, the variant is most likely benign based on current computational evidence, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.629350Binding0.2990.8740.250-4.419Likely Benign0.090Likely BenignLikely Benign0.045Likely Benign-0.31Neutral0.990Probably Damaging0.796Possibly Damaging2.49Pathogenic0.03Affected0.08070.399742-1.918.03
c.28C>T
R10W
2D
AIThe SynGAP1 R10W missense variant is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33420292‑C‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (which itself is “Likely Benign”). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.513657Binding0.3300.9150.625Uncertain 16-33420292-C-T21.30e-6-5.707Likely Benign0.503AmbiguousLikely Benign0.236Likely Benign-0.31Neutral0.964Probably Damaging0.190Benign4.10Benign0.00Affected4.3210.14610.45422-33.630.03
c.3152G>A
G1051D
2D
AISynGAP1 missense variant G1051D is listed in ClinVar as Benign and is present in gnomAD (variant ID 6‑33443704‑G‑A). Prediction tools that classify the variant as benign include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict pathogenicity are polyPhen‑2 HumDiv, ESM1b, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (two benign versus two pathogenic votes), and Foldetta stability analysis is unavailable. Overall, the balance of evidence favors a benign effect, consistent with the ClinVar annotation and not contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.900141Binding0.3580.9360.875Benign 16-33443704-G-A21.24e-6-9.379Likely Pathogenic0.311Likely BenignLikely Benign0.445Likely Benign-0.31Neutral0.761Possibly Damaging0.239Benign-0.74Pathogenic0.39Tolerated3.7750.18720.2235-11-3.158.04
c.3842C>G
A1281G
2D
AIThe SynGAP1 missense variant A1281G is reported as “Likely Benign” by the SGM‑Consensus tool and is absent from ClinVar and gnomAD. All standard in‑silico predictors (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default) classify the change as benign, so the benign‑prediction group contains every listed tool, while no tool predicts pathogenicity. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates likely benign. Foldetta results are unavailable. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.823549Disordered0.821556Binding0.4340.7210.875-3.829Likely Benign0.075Likely BenignLikely Benign0.058Likely Benign-0.31Neutral0.006Benign0.008Benign2.66Benign0.27Tolerated0.23820.321510-2.2-14.03
c.58C>G
P20A
2D
AIThe SynGAP1 missense variant P20A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. Foldetta results are not available, so they do not influence the assessment. Overall, the majority of evidence points to a benign effect for P20A, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.529623Disordered0.442804Uncertain0.4480.8990.500-3.120Likely Benign0.128Likely BenignLikely Benign0.068Likely Benign-0.31Neutral0.805Possibly Damaging0.539Possibly Damaging4.31Benign0.00Affected0.37530.55201-13.4-26.04
c.62T>G
F21C
2D
AIThe SynGAP1 missense variant F21C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for F21C. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.443284Uncertain0.3690.8970.500-3.698Likely Benign0.686Likely PathogenicLikely Benign0.151Likely Benign-0.31Neutral0.880Possibly Damaging0.759Possibly Damaging4.12Benign0.00Affected0.28730.2171-4-2-0.3-44.04
c.127G>A
G43S
2D
AIThe SynGAP1 missense variant G43S is listed in ClinVar with an “Uncertain” status and is present in gnomAD (6‑33423536‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (derived from the same four high‑accuracy tools) also as benign; Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.308712Structured0.431462Uncertain0.3960.7620.375Uncertain 26-33423536-G-A16.20e-7-3.301Likely Benign0.078Likely BenignLikely Benign0.057Likely Benign-0.30Neutral0.162Benign0.096Benign4.29Benign0.00Affected4.3210.25590.406410-0.430.03
c.1729G>T
A577S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A577S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, FoldX, Foldetta, premPS, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) all indicate benign or likely benign. In contrast, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM predict pathogenicity, while Rosetta remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign, the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts benign stability. Overall, the majority of evidence supports a benign classification, and this is consistent with the absence of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.113710Structured0.019074Uncertain0.9130.2390.000-4.417Likely Benign0.151Likely BenignLikely Benign0.10Likely Benign0.00.60Ambiguous0.35Likely Benign0.05Likely Benign0.342Likely Benign-0.30Neutral0.981Probably Damaging0.992Probably Damaging-1.24Pathogenic0.80Tolerated0.27630.505611-2.616.00
c.2558G>C
G853A
2D
AIThe SynGAP1 missense variant G853A is predicted to be benign by every evaluated in‑silico tool. Benign predictions come from REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports a benign effect, and the SGM Consensus (a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. ClinVar contains no entry for G853A, and the variant is absent from gnomAD. Based on the unanimous benign predictions and lack of contrary evidence, the variant is most likely benign, with no contradiction from ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.657645Disordered0.496246Uncertain0.2840.8150.625-4.440Likely Benign0.082Likely BenignLikely Benign0.165Likely Benign-0.30Neutral0.124Benign0.130Benign4.20Benign0.30Tolerated0.39290.5527102.214.03
c.2837G>T
G946V
2D
AIThe SynGAP1 missense variant G946V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. ESM1b is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for G946V, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985417Disordered0.845792Binding0.3570.9200.750-7.528In-Between0.109Likely BenignLikely Benign0.368Likely Benign-0.30Neutral0.901Possibly Damaging0.516Possibly Damaging4.57Benign0.00Affected0.15240.3707-1-34.642.08
c.2890C>A
H964N
2D
AIThe SynGAP1 missense variant H964N is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-8.073Likely Pathogenic0.084Likely BenignLikely Benign0.098Likely Benign-0.30Neutral0.000Benign0.000Benign4.18Benign0.64Tolerated0.19880.349521-0.3-23.04
c.289G>A
E97K
2D
AIThe SynGAP1 missense variant E97K is catalogued in gnomAD (ID 6‑33425897‑G‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from both general and high‑accuracy predictors points to a benign effect. This conclusion is not contradicted by ClinVar, as no ClinVar classification exists for E97K.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.609018Binding0.3400.8670.6256-33425897-G-A16.20e-7-4.972Likely Benign0.643Likely PathogenicLikely Benign0.139Likely Benign-0.30Neutral0.976Probably Damaging0.651Possibly Damaging4.16Benign0.00Affected4.3210.27090.790810-0.4-0.94
c.2974G>A
V992I
2D
AIThe SynGAP1 missense variant V992I is catalogued in gnomAD (ID 6‑33443526‑G‑A) but has no ClinVar entry. Across a broad panel of in silico predictors, every tool reports a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as tolerated or benign. No tool in the set indicates pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a Likely Benign verdict. Foldetta results are not available for this variant. Consequently, the variant is most likely benign, and this prediction does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.921728Binding0.3310.9170.7506-33443526-G-A53.10e-6-3.851Likely Benign0.074Likely BenignLikely Benign0.052Likely Benign-0.30Neutral0.302Benign0.089Benign4.20Benign0.29Tolerated4.3220.09390.4541340.314.03
c.3188G>A
G1063D
2D
AIThe SynGAP1 missense variant G1063D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is likely benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the computational evidence overwhelmingly supports a benign impact for G1063D, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975134Disordered0.945784Binding0.3940.9130.875-6.950Likely Benign0.367AmbiguousLikely Benign0.057Likely Benign-0.30Neutral0.411Benign0.058Benign4.24Benign0.08Tolerated0.18780.30261-1-3.158.04
c.3304G>A
A1102T
2D
AIThe SynGAP1 missense variant A1102T is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443856‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.915074Disordered0.962659Binding0.3880.8590.875Uncertain 16-33443856-G-A117.17e-6-3.540Likely Benign0.070Likely BenignLikely Benign0.044Likely Benign-0.30Neutral0.001Benign0.001Benign2.32Pathogenic0.95Tolerated3.7750.17550.769910-2.530.03
c.3310C>T
P1104S
2D
AIThe SynGAP1 missense variant P1104S is listed in ClinVar (ID 2912797.0) as Benign and is present in gnomAD (variant ID 6‑33443862‑C‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is Likely Benign, and AlphaMissense‑Optimized also reports Benign. Foldetta results are not available. Overall, the majority of computational evidence supports a benign classification, which is consistent with the ClinVar status. Thus, the variant is most likely benign and does not contradict the ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.936162Disordered0.954801Binding0.4400.8630.875Benign 16-33443862-C-T16.54e-7-2.330Likely Benign0.073Likely BenignLikely Benign0.088Likely Benign-0.30Neutral0.770Possibly Damaging0.404Benign2.77Benign0.10Tolerated3.7750.32710.5746-110.8-10.04
c.3332A>G
K1111R
2D
AIThe SynGAP1 missense variant K1111R is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.910643Disordered0.921455Binding0.3000.9020.875-2.495Likely Benign0.082Likely BenignLikely Benign0.059Likely Benign-0.30Neutral0.006Benign0.006Benign2.74Benign0.71Tolerated0.46640.203132-0.628.01
c.3398T>C
I1133T
2D
AIThe SynGAP1 missense variant I1133T has no ClinVar entry and is present in gnomAD (ID 6‑33443950‑T‑C). Consensus among most tools is benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict a benign effect, while AlphaMissense‑Default remains uncertain and no tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates “Likely Benign,” and Foldetta’s protein‑folding stability analysis is unavailable. Overall, the evidence strongly supports a benign classification, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.832785Binding0.3160.8920.7506-33443950-T-C-4.522Likely Benign0.563AmbiguousLikely Benign0.275Likely Benign-0.30Neutral0.026Benign0.030Benign5.50Benign0.18Tolerated4.3230.10070.1975-10-5.2-12.05
c.34A>C
S12R
2D
AIThe SynGAP1 missense variant S12R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (majority of the four high‑accuracy tools) also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.490599Uncertain0.3550.9160.500-4.033Likely Benign0.500AmbiguousLikely Benign0.116Likely Benign-0.30Neutral0.000Benign0.000Benign4.09Benign0.00Affected4.3210.09440.36780-1-3.769.11
c.3517A>C
I1173L
2D
AIThe SynGAP1 missense variant I1173L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate a benign effect. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly supports a benign classification, and there is no conflict with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.501700Disordered0.653145Binding0.5210.7560.375-1.792Likely Benign0.202Likely BenignLikely Benign0.218Likely Benign-0.30Neutral0.152Benign0.102Benign5.41Benign0.97Tolerated0.07450.300422-0.70.00
c.36C>A
S12R
2D
AIThe SynGAP1 missense variant S12R is present in gnomAD (ID 6‑33420300‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score all report benign or likely benign. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors benign. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.490599Uncertain0.3550.9160.5006-33420300-C-A-4.033Likely Benign0.500AmbiguousLikely Benign0.097Likely Benign-0.30Neutral0.000Benign0.000Benign4.09Benign0.00Affected4.3210.09440.36780-1-3.769.11
c.36C>G
S12R
2D
AIThe SynGAP1 missense variant S12R is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33420300‑C‑G). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors a benign classification; Foldetta’s protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.490599Uncertain0.3550.9160.500Uncertain 16-33420300-C-G42.59e-6-4.033Likely Benign0.500AmbiguousLikely Benign0.097Likely Benign-0.30Neutral0.000Benign0.000Benign4.09Benign0.00Affected4.3210.09440.36780-1-3.769.11
c.3835G>A
A1279T
2D
AIThe SynGAP1 missense variant A1279T is listed in ClinVar with an “Uncertain” status and is present in gnomAD (variant ID 6‑33447883‑G‑A). All available in silico predictors report a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized are benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” No tool predicts pathogenicity. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is benign; Foldetta results are not available. Overall, the computational evidence strongly supports a benign classification, which does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.842060Disordered0.814139Binding0.4850.7240.750Uncertain 26-33447883-G-A21.29e-6-4.871Likely Benign0.071Likely BenignLikely Benign0.178Likely Benign-0.30Neutral0.001Benign0.000Benign2.71Benign0.09Tolerated3.7750.10270.587110-2.530.03
c.3955G>A
A1319T
2D
AIThe SynGAP1 missense variant A1319T is reported in gnomAD (variant ID 6‑33451829‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also predicts a benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT each predict a pathogenic effect. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, SGM‑Consensus is benign, and the Foldetta stability analysis is unavailable. Overall, the majority of evidence supports a benign impact for A1319T, and this conclusion does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.842060Disordered0.960481Binding0.4540.8510.7506-33451829-G-A-4.861Likely Benign0.076Likely BenignLikely Benign0.097Likely Benign-0.30Neutral0.917Possibly Damaging0.500Possibly Damaging4.13Benign0.03Affected3.7750.19440.717401-2.530.03
c.1160G>C
G387A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G387A is reported in gnomAD (variant ID 6‑33438065‑G‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only FATHMM predicts it as pathogenic. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, is inconclusive (treated as unavailable). No other tools provide decisive evidence. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.642678Disordered0.422910Uncertain0.2930.8610.7506-33438065-G-C31.87e-6-6.313Likely Benign0.104Likely BenignLikely Benign1.95Ambiguous0.11.68Ambiguous1.82Ambiguous-0.02Likely Benign0.300Likely Benign-0.29Neutral0.007Benign0.010Benign1.33Pathogenic0.06Tolerated4.3230.41490.4576012.214.03
c.1339G>C
V447L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V447L is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Prediction tools that classify the variant as benign include REVEL, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict pathogenicity are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Uncertain results are reported by FoldX, Rosetta, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, the SGM‑Consensus as Likely Benign, and Foldetta as Benign. Overall, the majority of evidence points to a benign effect, and this consensus does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.250310Structured0.283801Uncertain0.9700.2430.000Uncertain 1-5.136Likely Benign0.491AmbiguousLikely Benign-1.13Ambiguous0.10.54Ambiguous-0.30Likely Benign0.03Likely Benign0.180Likely Benign-0.29Neutral0.947Possibly Damaging0.851Possibly Damaging3.61Benign0.90Tolerated3.37320.07570.347712-0.414.03
c.183G>C
E61D
2D
AIThe SynGAP1 missense variant E61D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumVar and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. The variant’s predicted benign status does not contradict ClinVar, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.352862Structured0.477329Uncertain0.5180.6990.125-4.394Likely Benign0.231Likely BenignLikely Benign0.035Likely Benign-0.29Neutral0.267Benign0.585Possibly Damaging4.11Benign0.00Affected0.18950.3851320.0-14.03
c.183G>T
E61D
2D
AIThe SynGAP1 missense variant E61D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumVar and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. The variant’s predicted benign status does not contradict ClinVar, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.352862Structured0.477329Uncertain0.5180.6990.125-4.394Likely Benign0.231Likely BenignLikely Benign0.035Likely Benign-0.29Neutral0.267Benign0.585Possibly Damaging4.11Benign0.00Affected0.18950.3851320.0-14.03
c.199C>A
L67I
2D
AIThe SynGAP1 missense variant L67I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. In contrast, polyPhen‑2 HumDiv and SIFT predict pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for the variant, and this is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.458154Structured0.473668Uncertain0.4280.7610.125-4.387Likely Benign0.307Likely BenignLikely Benign0.084Likely Benign-0.29Neutral0.458Possibly Damaging0.364Benign4.10Benign0.00Affected0.06800.2919220.70.00
c.207C>G
I69M
2D
AIThe SynGAP1 missense variant I69M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for I69M, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.575842Disordered0.466129Uncertain0.4370.7860.375-4.071Likely Benign0.087Likely BenignLikely Benign0.075Likely Benign-0.29Neutral0.943Possibly Damaging0.703Possibly Damaging4.17Benign0.00Affected0.05790.290621-2.618.03
c.2237T>C
V746A
2D
AIThe SynGAP1 missense variant V746A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.808535Disordered0.576597Binding0.3360.8670.875-2.875Likely Benign0.087Likely BenignLikely Benign0.063Likely Benign-0.29Neutral0.010Benign0.005Benign2.80Benign0.21Tolerated0.25660.253100-2.4-28.05
c.22A>T
I8F
2D
AIThe SynGAP1 missense variant I8F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.490133Structured0.543080Binding0.3410.9160.625-3.000Likely Benign0.092Likely BenignLikely Benign0.116Likely Benign-0.29Neutral0.000Benign0.000Benign4.02Benign0.00Affected0.04830.287110-1.734.02
c.2378A>G
K793R
2D
AIThe SynGAP1 missense variant K793R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that assess sequence conservation and functional impact all converge on a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. No tool in the dataset indicates pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign,” while Foldetta results are unavailable. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.971072Disordered0.426071Uncertain0.3440.9010.875-2.789Likely Benign0.113Likely BenignLikely Benign0.026Likely Benign-0.29Neutral0.001Benign0.003Benign4.18Benign0.22Tolerated0.52700.1657Weaken32-0.628.01
c.2551C>T
P851S
2D
AIThe SynGAP1 missense variant P851S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). In contrast, the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic effect. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. Foldetta results are not available for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.648219Disordered0.526893Binding0.3470.8190.625-3.696Likely Benign0.061Likely BenignLikely Benign0.103Likely Benign-0.29Neutral0.997Probably Damaging0.992Probably Damaging4.27Benign0.12Tolerated0.34980.61581-10.8-10.04
c.2641T>G
L881V
2D
AIThe SynGAP1 missense variant L881V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect. The variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.629350Binding0.2990.8740.250-3.961Likely Benign0.079Likely BenignLikely Benign0.061Likely Benign-0.29Neutral0.790Possibly Damaging0.266Benign2.60Benign0.39Tolerated0.15990.3053210.4-14.03
c.2742C>A
D914E
2D
AIThe SynGAP1 missense variant D914E is reported in gnomAD (ID 6‑33443294‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv flags it as pathogenic, creating a single discordant call. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification, and AlphaMissense‑Optimized independently predicts benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.699094Disordered0.785987Binding0.3200.8920.2506-33443294-C-A53.10e-6-3.231Likely Benign0.170Likely BenignLikely Benign0.133Likely Benign-0.29Neutral0.893Possibly Damaging0.418Benign2.87Benign1.00Tolerated3.7750.19090.7088230.014.03
c.2742C>G
D914E
2D
AIThe SynGAP1 missense variant D914E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence supports a benign classification for D914E, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.699094Disordered0.785987Binding0.3200.8920.250-3.231Likely Benign0.170Likely BenignLikely Benign0.133Likely Benign-0.29Neutral0.893Possibly Damaging0.418Benign2.87Benign1.00Tolerated3.7750.19090.7088230.014.03
c.2833C>A
H945N
2D
AIThe SynGAP1 missense variant H945N is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability result is available. Overall, the majority of evidence points to a benign effect for H945N, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.750-5.709Likely Benign0.078Likely BenignLikely Benign0.266Likely Benign-0.29Neutral0.982Probably Damaging0.870Possibly Damaging5.03Benign0.05Affected0.25560.299721-0.3-23.04
c.3178G>C
G1060R
2D
AIThe SynGAP1 missense variant G1060R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for G1060R, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979242Disordered0.913048Binding0.4070.9280.875-8.225Likely Pathogenic0.323Likely BenignLikely Benign0.362Likely Benign-0.29Neutral0.971Probably Damaging0.580Possibly Damaging2.63Benign0.17Tolerated0.10380.4342-3-2-4.199.14
c.3241G>T
A1081S
2D
AIThe SynGAP1 missense variant A1081S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable. Consequently, the variant is most likely benign, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.874069Disordered0.979759Binding0.2880.8950.750-3.536Likely Benign0.109Likely BenignLikely Benign0.078Likely Benign-0.29Neutral0.021Benign0.031Benign4.02Benign0.23Tolerated0.22680.491511-2.616.00
c.3490C>A
L1164M
2D
AIThe SynGAP1 missense variant L1164M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, indicates a likely benign effect. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also leans benign. No Foldetta (FoldX‑MD/ Rosetta stability) result is available, so it does not influence the interpretation. Overall, the majority of computational evidence points to a benign impact for the variant, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.517562Disordered0.853935Binding0.3250.8150.375-5.493Likely Benign0.757Likely PathogenicLikely Benign0.349Likely Benign-0.29Neutral0.999Probably Damaging0.998Probably Damaging5.34Benign0.13Tolerated0.08470.337842-1.918.03
c.3631A>G
M1211V
2D
AIThe SynGAP1 missense variant M1211V is listed in ClinVar as Benign (ClinVar ID 3674914.0) and is present in gnomAD (ID 6‑33446623‑A‑G). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as Likely Benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, aligning with the ClinVar classification and not contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.585406Disordered0.578388Binding0.8760.5650.500Benign 16-33446623-A-G31.86e-6-2.101Likely Benign0.258Likely BenignLikely Benign0.412Likely Benign-0.29Neutral0.932Possibly Damaging0.949Probably Damaging5.43Benign0.72Tolerated3.7750.26760.2720122.3-32.06
c.3898C>T
P1300S
2D
AIThe SynGAP1 missense variant P1300S is reported in gnomAD (variant ID 6‑33451772‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv flags it as pathogenic, creating a single discordant call. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods indicates that P1300S is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.885826Binding0.4000.8340.8756-33451772-C-T16.20e-7-3.476Likely Benign0.088Likely BenignLikely Benign0.036Likely Benign-0.29Neutral0.481Possibly Damaging0.157Benign2.89Benign0.27Tolerated3.7750.32420.4139-110.8-10.04
c.1153T>G
S385A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S385A is catalogued in gnomAD (variant ID 6‑33438058‑T‑G) but has no entry in ClinVar. All available in silico predictors report a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments concur: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is “Likely Benign”; and Foldetta (combining FoldX‑MD and Rosetta outputs) is benign. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.733139Disordered0.425480Uncertain0.3410.9250.7506-33438058-T-G-4.412Likely Benign0.083Likely BenignLikely Benign0.03Likely Benign0.10.19Likely Benign0.11Likely Benign0.07Likely Benign0.243Likely Benign-0.28Neutral0.140Benign0.355Benign4.65Benign0.13Tolerated4.3230.49100.5366112.6-16.00
c.213C>A
D71E
2D
AIThe SynGAP1 missense variant D71E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and AlphaMissense‑Optimized also reports a benign prediction. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.575842Disordered0.456046Uncertain0.3500.7990.375-3.276Likely Benign0.134Likely BenignLikely Benign0.079Likely Benign-0.28Neutral0.000Benign0.000Benign4.39Benign0.00Affected0.14900.5922320.014.03

Found 8751 rows. Show 800 rows per page. Page 10/11 « Previous | Next »