SynGap Missense Server

Table of SynGAP1 Isoform α2 (UniProt Q96PV0-1) Missense Variants.

c.dna Variant SGM Consensus Domain and Structure information: based on WT protein Annotated databases Deep learning-based pathogenicity predictions Folding stability-based pathogenicity predictions Sequence/structure-based pathogenicity predictions Phase Separation Evolutionary/physical properties Molecular Dynamics-based analysis DOI
Domain IUPred2 ANCHOR2 AlphaFold MobiDB PhosphoSitePlus ClinVar gnomAD ESM1b AlphaMissense FoldX Rosetta Foldetta PremPS REVEL PROVEAN PolyPhen-2 HumDiv PolyPhen-2 HumVar FATHMM SIFT PSMutPred PAM Physical SASA Normalized B-factor backbone Normalized B-factor sidechain SynGAP Structural Annotation
Score Prediction Score Prediction pLDDT disorder disorder LTP HTP KL PTM Clinical Status Review Subm. ID Allele count Allele freq. LLR score Prediction Pathogenicity Class Optimized Average ΔΔG Prediction StdDev ΔΔG Prediction ΔΔG Prediction ΔΔG Prediction Score Prediction Score Prediction pph2_prob Prediction pph2_prob Prediction Nervous System Score Prediction Prediction Status Conservation Sequences IP RF SP RF Prediction PAM250 PAM120 Hydropathy Δ MW Δ Average Δ Δ StdDev Δ StdDev Secondary Tertiary bonds Inside out GAP-Ras interface At membrane No effect MD Alert Verdict Description
c.2833C>G
H945D
2D
AIThe SynGAP1 missense variant H945D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Pathogenic predictions come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for H945D, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.750-6.572Likely Benign0.191Likely BenignLikely Benign0.396Likely Benign-0.18Neutral0.982Probably Damaging0.870Possibly Damaging5.02Benign0.04Affected0.28030.22751-1-0.3-22.05
c.2833C>T
H945Y
2D
AIThe SynGAP1 missense variant H945Y is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability result is available. Overall, the majority of evidence points to a benign effect for H945Y, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.750-6.036Likely Benign0.112Likely BenignLikely Benign0.335Likely Benign-0.07Neutral0.982Probably Damaging0.903Possibly Damaging5.27Benign0.05Affected0.21020.3912021.926.03
c.2834A>C
H945P
2D
AIThe SynGAP1 missense variant H945P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Based on the preponderance of benign predictions and the lack of pathogenic evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.750-1.962Likely Benign0.055Likely BenignLikely Benign0.420Likely Benign-0.34Neutral0.012Benign0.047Benign5.04Benign0.05Affected0.27300.39070-21.6-40.02
c.2834A>G
H945R
2D
AIThe SynGAP1 missense variant H945R is reported in gnomAD (variant ID 6‑33443386‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.7506-33443386-A-G16.20e-7-5.186Likely Benign0.118Likely BenignLikely Benign0.333Likely Benign-0.59Neutral0.982Probably Damaging0.903Possibly Damaging5.05Benign0.08Tolerated4.3240.27640.302002-1.319.05
c.2834A>T
H945L
2D
AIThe SynGAP1 missense variant H945L is reported in gnomAD (ID 6‑33443386‑A‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict the variant to be pathogenic. High‑accuracy assessments reinforce the benign view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this is consistent with the absence of a pathogenic ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.7506-33443386-A-T21.24e-6-4.741Likely Benign0.088Likely BenignLikely Benign0.399Likely Benign0.16Neutral0.948Possibly Damaging0.863Possibly Damaging5.05Benign1.00Tolerated4.3240.20850.4526-3-27.0-23.98
c.2835T>G
H945Q
2D
AIThe SynGAP1 missense variant H945Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. Only two tools, polyPhen‑2 HumDiv and polyPhen‑2 HumVar, predict a pathogenic effect. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for H945Q, and this conclusion is not contradicted by any ClinVar classification (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.750-5.248Likely Benign0.091Likely BenignLikely Benign0.343Likely Benign-0.36Neutral0.995Probably Damaging0.939Probably Damaging5.03Benign0.06Tolerated4.3240.26710.312830-0.3-9.01
c.2836G>A
G946R
2D
AIThe SynGAP1 missense variant G946R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while ESM1b is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus itself is Likely Benign. Foldetta results are unavailable. Overall, the majority of computational evidence indicates that G946R is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985417Disordered0.845792Binding0.3570.9200.750-7.127In-Between0.308Likely BenignLikely Benign0.296Likely Benign-0.69Neutral0.818Possibly Damaging0.435Benign4.65Benign0.00Affected0.11570.5133-3-2-4.199.14
c.2836G>C
G946R
2D
AIThe SynGAP1 missense variant G946R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while ESM1b is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus itself is Likely Benign. Foldetta results are unavailable. Overall, the majority of computational evidence indicates that G946R is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985417Disordered0.845792Binding0.3570.9200.750-7.127In-Between0.308Likely BenignLikely Benign0.296Likely Benign-0.69Neutral0.818Possibly Damaging0.435Benign4.65Benign0.00Affected0.11570.5133-3-2-4.199.14
c.2837G>C
G946A
2D
AIThe SynGAP1 missense variant G946A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for G946A, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985417Disordered0.845792Binding0.3570.9200.750-7.004In-Between0.079Likely BenignLikely Benign0.191Likely Benign0.33Neutral0.649Possibly Damaging0.209Benign4.77Benign0.00Affected0.33780.4957102.214.03
c.2837G>T
G946V
2D
AIThe SynGAP1 missense variant G946V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. ESM1b is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for G946V, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985417Disordered0.845792Binding0.3570.9200.750-7.528In-Between0.109Likely BenignLikely Benign0.368Likely Benign-0.30Neutral0.901Possibly Damaging0.516Possibly Damaging4.57Benign0.00Affected0.15240.3707-1-34.642.08
c.2839G>A
G947R
2D
AIThe SynGAP1 missense variant G947R is listed in gnomAD (6-33443391-G-A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Optimized) and pathogenic (SIFT). Two tools remain uncertain (ESM1b, AlphaMissense‑Default). High‑accuracy assessments show AlphaMissense‑Optimized predicts a benign effect, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—does not reach a definitive conclusion (two benign, two uncertain). Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no reported result for this variant. Overall, the preponderance of evidence points to a benign impact, and this assessment does not contradict any ClinVar status, as none is available.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988695Disordered0.850554Binding0.3580.9190.7506-33443391-G-A63.72e-6-7.481In-Between0.343AmbiguousLikely Benign0.273Likely Benign-0.60Neutral0.411Benign0.140Benign4.94Benign0.04Affected4.3240.10340.4733-2-3-4.199.14
c.2839G>C
G947R
2D
AIThe SynGAP1 missense variant G947R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while ESM1b and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive, and Foldetta stability analysis is unavailable. Overall, the balance of evidence favors a benign classification, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988695Disordered0.850554Binding0.3580.9190.750-7.481In-Between0.343AmbiguousLikely Benign0.273Likely Benign-0.60Neutral0.411Benign0.140Benign4.94Benign0.04Affected4.3240.10340.4733-2-3-4.199.14
c.2839G>T
G947W
2D
AIThe SynGAP1 missense variant G947W has no ClinVar record and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988695Disordered0.850554Binding0.3580.9190.750-10.819Likely Pathogenic0.285Likely BenignLikely Benign0.349Likely Benign-1.21Neutral0.983Probably Damaging0.868Possibly Damaging4.90Benign0.01Affected0.09140.4059-7-2-0.5129.16
c.283C>A
H95N
2D
AIThe SynGAP1 missense variant H95N is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) indicates likely benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the computational evidence overwhelmingly supports a benign classification for H95N, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.661982Disordered0.590542Binding0.3350.8750.625-3.454Likely Benign0.069Likely BenignLikely Benign0.089Likely Benign-1.12Neutral0.219Benign0.009Benign4.20Benign0.00Affected0.18210.249121-0.3-23.04
c.283C>G
H95D
2D
AIThe SynGAP1 missense variant H95D is not listed in ClinVar and is present in gnomAD (variant ID 6‑33425891‑C‑G). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all indicate benign or likely benign. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign, and the SGM‑Consensus also reports likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the computational evidence overwhelmingly supports a benign classification, and this is consistent with the absence of a ClinVar pathogenic report.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.661982Disordered0.590542Binding0.3350.8750.6256-33425891-C-G31.86e-6-2.387Likely Benign0.188Likely BenignLikely Benign0.092Likely Benign-0.81Neutral0.084Benign0.009Benign4.22Benign0.00Affected4.3210.27590.1801-11-0.3-22.05
c.283C>T
H95Y
2D
AIThe SynGAP1 missense variant H95Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign. Foldetta results are unavailable. Overall, the majority of evidence indicates that H95Y is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.661982Disordered0.590542Binding0.3350.8750.625-3.610Likely Benign0.112Likely BenignLikely Benign0.090Likely Benign-1.45Neutral0.219Benign0.014Benign4.14Benign0.00Affected0.08800.4122021.926.03
c.2840G>A
G947E
2D
AIThe SynGAP1 missense variant G947E is reported in ClinVar as “Not submitted” and is present in gnomAD (variant ID 6-33443392-G-A). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome, creating a single discordant signal. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that G947E is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988695Disordered0.850554Binding0.3580.9190.7506-33443392-G-A16.20e-7-9.574Likely Pathogenic0.243Likely BenignLikely Benign0.302Likely Benign0.08Neutral0.126Benign0.096Benign4.92Benign0.10Tolerated4.3240.15550.4259-20-3.172.06
c.2840G>T
G947V
2D
AIThe SynGAP1 missense variant G947V is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate benign, whereas polyPhen‑2 HumDiv and SIFT predict pathogenicity; ESM1b remains uncertain. High‑accuracy methods reinforce the benign assessment: AlphaMissense‑Optimized scores benign, the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign,” and Foldetta data are not available. Overall, the preponderance of evidence points to a benign impact for G947V, and this conclusion is consistent with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988695Disordered0.850554Binding0.3580.9190.750-7.171In-Between0.105Likely BenignLikely Benign0.296Likely Benign-1.11Neutral0.586Possibly Damaging0.303Benign4.93Benign0.01Affected0.14430.3507-1-34.642.08
c.2842G>A
G948S
2D
AIThe SynGAP1 missense variant G948S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools that assess sequence conservation and structural impact uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this benign assessment: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the collective evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.862121Binding0.3650.9190.750-4.760Likely Benign0.080Likely BenignLikely Benign0.177Likely Benign1.09Neutral0.068Benign0.026Benign4.57Benign1.00Tolerated0.24660.550210-0.430.03
c.2842G>C
G948R
2D
AIThe SynGAP1 missense variant G948R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and SIFT—suggest a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.862121Binding0.3650.9190.750-6.782Likely Benign0.315Likely BenignLikely Benign0.266Likely Benign-0.60Neutral0.818Possibly Damaging0.435Benign4.58Benign0.04Affected0.10690.4933-3-2-4.199.14
c.2842G>T
G948C
2D
AIThe SynGAP1 missense variant G948C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. The high‑accuracy consensus (SGM‑Consensus) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the majority of evidence points to a benign impact. The predictions do not contradict ClinVar status, as no ClinVar assertion exists for this variant. Thus, based on the available computational predictions, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.862121Binding0.3650.9190.750-10.254Likely Pathogenic0.102Likely BenignLikely Benign0.247Likely Benign-0.77Neutral0.997Probably Damaging0.840Possibly Damaging4.50Benign0.04Affected0.14220.4439-3-32.946.09
c.2843G>A
G948D
2D
AIThe SynGAP1 missense variant G948D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.862121Binding0.3650.9190.750-8.423Likely Pathogenic0.267Likely BenignLikely Benign0.279Likely Benign0.15Neutral0.818Possibly Damaging0.266Benign4.55Benign0.11Tolerated0.18710.28261-1-3.158.04
c.2843G>C
G948A
2D
AIThe SynGAP1 missense variant G948A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.862121Binding0.3650.9190.750-5.627Likely Benign0.078Likely BenignLikely Benign0.189Likely Benign0.04Neutral0.288Benign0.103Benign4.64Benign0.39Tolerated0.33500.4957102.214.03
c.2843G>T
G948V
2D
AIThe SynGAP1 missense variant G948V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods indicates that G948V is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.862121Binding0.3650.9190.750-6.541Likely Benign0.102Likely BenignLikely Benign0.256Likely Benign-0.48Neutral0.901Possibly Damaging0.435Benign4.52Benign0.06Tolerated0.14640.3507-1-34.642.08
c.2845G>C
G949R
2D
AIThe SynGAP1 missense variant G949R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Consensus from standard in silico predictors shows a split: benign calls come from REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized, while pathogenic calls come from polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; ESM1b is uncertain. High‑accuracy assessment further supports a benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign outcome, and Foldetta data are unavailable. Overall, the preponderance of evidence indicates the variant is most likely benign, and this conclusion does not conflict with any ClinVar annotation because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988861Disordered0.874971Binding0.3650.9230.750-7.650In-Between0.301Likely BenignLikely Benign0.317Likely Benign-0.14Neutral0.997Probably Damaging0.934Probably Damaging2.21Pathogenic0.01Affected0.10950.4569-3-2-4.199.14
c.2845G>T
G949C
2D
AIThe SynGAP1 missense variant G949C is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. The SGM Consensus, which takes a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (two benign vs. two pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of available predictions (five pathogenic vs. four benign) indicate that the variant is most likely pathogenic. This assessment does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988861Disordered0.874971Binding0.3650.9230.750-10.580Likely Pathogenic0.091Likely BenignLikely Benign0.345Likely Benign-1.02Neutral1.000Probably Damaging0.975Probably Damaging2.21Pathogenic0.01Affected0.14800.4097-3-32.946.09
c.2846G>A
G949D
2D
AIThe SynGAP1 missense variant G949D is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. The SGM Consensus, which takes a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (2 benign vs. 2 pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of high‑confidence predictors (5 pathogenic vs. 4 benign) indicate a pathogenic impact. This conclusion is not contradicted by ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988861Disordered0.874971Binding0.3650.9230.750-8.692Likely Pathogenic0.239Likely BenignLikely Benign0.316Likely Benign0.25Neutral0.945Possibly Damaging0.753Possibly Damaging2.21Pathogenic0.02Affected0.19270.28261-1-3.158.04
c.2846G>C
G949A
2D
AIThe SynGAP1 missense variant G949A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is “Likely Benign” (3 benign vs. 1 pathogenic votes). High‑accuracy methods confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988861Disordered0.874971Binding0.3650.9230.750-6.838Likely Benign0.072Likely BenignLikely Benign0.274Likely Benign-0.08Neutral0.779Possibly Damaging0.425Benign2.28Pathogenic0.08Tolerated0.33850.4414102.214.03
c.2846G>T
G949V
2D
AIThe SynGAP1 missense variant G949V is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors a benign outcome. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988861Disordered0.874971Binding0.3650.9230.750-7.364In-Between0.102Likely BenignLikely Benign0.328Likely Benign-0.55Neutral0.992Probably Damaging0.834Possibly Damaging2.21Pathogenic0.01Affected0.14930.3165-1-34.642.08
c.2848G>A
G950S
2D
AIThe SynGAP1 missense variant G950S is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; the Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.888649Binding0.3680.9230.750-5.286Likely Benign0.071Likely BenignLikely Benign0.288Likely Benign0.46Neutral0.004Benign0.008Benign2.32Pathogenic0.52Tolerated0.24590.550210-0.430.03
c.2848G>C
G950R
2D
AIThe SynGAP1 missense variant G950R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for G950R, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.888649Binding0.3680.9230.750-6.929Likely Benign0.318Likely BenignLikely Benign0.388Likely Benign-1.10Neutral0.002Benign0.005Benign2.26Pathogenic0.01Affected0.10090.4733-3-2-4.199.14
c.2848G>T
G950C
2D
AIThe SynGAP1 missense variant G950C is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. The SGM Consensus, which takes a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (2 benign vs. 2 pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of high‑confidence predictors (five pathogenic vs. four benign) indicate a pathogenic impact. This conclusion is not contradicted by ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.888649Binding0.3680.9230.750-9.589Likely Pathogenic0.092Likely BenignLikely Benign0.395Likely Benign-0.35Neutral0.983Probably Damaging0.750Possibly Damaging2.26Pathogenic0.01Affected0.14060.4439-3-32.946.09
c.2849G>A
G950D
2D
AIThe SynGAP1 missense variant G950D is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM, while ESM1b remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign outcome. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.888649Binding0.3680.9230.750-7.515In-Between0.245Likely BenignLikely Benign0.402Likely Benign-0.61Neutral0.411Benign0.131Benign2.26Pathogenic0.02Affected0.18740.28261-1-3.158.04
c.2849G>C
G950A
2D
AIThe SynGAP1 missense variant G950A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only FATHMM predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict, reflecting the majority of benign calls. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.888649Binding0.3680.9230.750-6.557Likely Benign0.081Likely BenignLikely Benign0.339Likely Benign-0.13Neutral0.059Benign0.061Benign2.28Pathogenic0.08Tolerated0.33430.4957102.214.03
c.2849G>T
G950V
2D
AIThe SynGAP1 missense variant G950V is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM, while ESM1b remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields a benign prediction. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence indicates that G950V is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.888649Binding0.3680.9230.750-7.796In-Between0.093Likely BenignLikely Benign0.428Likely Benign-0.91Neutral0.411Benign0.239Benign2.26Pathogenic0.01Affected0.13920.3507-1-34.642.08
c.284A>C
H95P
2D
AIThe SynGAP1 missense variant H95P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign, while the single pathogenic call comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) confirms a benign outcome. Foldetta results are unavailable, so they do not influence the assessment. Overall, the majority of evidence indicates that H95P is most likely benign, and this conclusion is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.661982Disordered0.590542Binding0.3350.8750.625-1.611Likely Benign0.045Likely BenignLikely Benign0.164Likely Benign-1.66Neutral0.000Benign0.000Benign4.19Benign0.00Affected0.22440.37040-21.6-40.02
c.284A>G
H95R
2D
AIThe SynGAP1 missense variant H95R is reported in gnomAD (variant ID 6‑33425892‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that H95R is most likely benign, and this conclusion does not contradict any ClinVar status (none is provided).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.661982Disordered0.590542Binding0.3350.8750.6256-33425892-A-G16.20e-7-2.789Likely Benign0.153Likely BenignLikely Benign0.043Likely Benign-1.31Neutral0.084Benign0.009Benign4.20Benign0.00Affected4.3210.19070.208702-1.319.05
c.284A>T
H95L
2D
AIThe SynGAP1 missense variant H95L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta results are not available for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.661982Disordered0.590542Binding0.3350.8750.625-1.967Likely Benign0.073Likely BenignLikely Benign0.085Likely Benign-2.31Neutral0.084Benign0.007Benign4.17Benign0.00Affected0.10170.5074-2-37.0-23.98
c.2851C>A
H951N
2D
AIThe SynGAP1 missense variant H951N is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the evidence strongly supports a benign classification, and this conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-5.833Likely Benign0.074Likely BenignLikely Benign0.140Likely Benign-0.41Neutral0.011Benign0.018Benign5.43Benign0.16Tolerated0.25900.319721-0.3-23.04
c.2851C>G
H951D
2D
AIThe SynGAP1 missense variant H951D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated methods. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on current predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-5.901Likely Benign0.188Likely BenignLikely Benign0.186Likely Benign-0.33Neutral0.000Benign0.001Benign5.43Benign0.46Tolerated0.28510.24751-1-0.3-22.05
c.2851C>T
H951Y
2D
AIThe SynGAP1 missense variant H951Y is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Overall, the consensus of high‑accuracy predictors (AlphaMissense‑Optimized and SGM‑Consensus) supports a benign interpretation. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-5.165Likely Benign0.113Likely BenignLikely Benign0.142Likely Benign-1.03Neutral0.000Benign0.001Benign5.61Benign0.10Tolerated0.22470.4112021.926.03
c.2852A>C
H951P
2D
AIThe SynGAP1 missense variant H951P is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign classification, and this conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-2.798Likely Benign0.051Likely BenignLikely Benign0.312Likely Benign-0.06Neutral0.000Benign0.001Benign5.43Benign0.14Tolerated0.27450.37070-21.6-40.02
c.2852A>T
H951L
2D
AIThe SynGAP1 missense variant H951L is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-4.822Likely Benign0.087Likely BenignLikely Benign0.192Likely Benign-0.99Neutral0.022Benign0.018Benign5.47Benign0.43Tolerated0.22240.4526-2-37.0-23.98
c.2853T>A
H951Q
2D
AIThe SynGAP1 missense variant H951Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-4.755Likely Benign0.089Likely BenignLikely Benign0.172Likely Benign-0.51Neutral0.001Benign0.002Benign5.43Benign0.29Tolerated0.27570.332830-0.3-9.01
c.2853T>G
H951Q
2D
AIThe SynGAP1 missense variant H951Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-4.755Likely Benign0.089Likely BenignLikely Benign0.171Likely Benign-0.51Neutral0.001Benign0.002Benign5.43Benign0.29Tolerated0.27570.332830-0.3-9.01
c.2854G>C
G952R
2D
AIThe SynGAP1 missense variant G952R is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that G952R is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.910621Binding0.3410.9260.750-5.974Likely Benign0.295Likely BenignLikely Benign0.139Likely Benign-0.93Neutral0.077Benign0.011Benign3.20Benign0.02Affected0.11450.4933-3-2-4.199.14
c.2854G>T
G952C
2D
AIThe SynGAP1 missense variant G952C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. Thus, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.910621Binding0.3410.9260.750-8.599Likely Pathogenic0.088Likely BenignLikely Benign0.272Likely Benign-0.18Neutral0.371Benign0.169Benign3.20Benign0.01Affected0.14580.4439-3-32.946.09
c.2855G>A
G952D
2D
AIThe SynGAP1 missense variant G952D is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools overwhelmingly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is labeled Likely Benign. Only SIFT predicts a pathogenic outcome, and ESM1b remains uncertain. High‑accuracy assessments corroborate the benign trend: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Overall, the computational evidence strongly supports a benign classification, and this is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.910621Binding0.3410.9260.750-7.299In-Between0.274Likely BenignLikely Benign0.241Likely Benign-0.75Neutral0.033Benign0.015Benign3.20Benign0.05Affected0.19280.28261-1-3.158.04
c.2855G>C
G952A
2D
AIThe SynGAP1 missense variant G952A is predicted to be benign by every evaluated in‑silico tool. Benign predictions are reported by REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method, has no available result for this variant. ClinVar contains no entry for G952A, so there is no conflicting clinical annotation. Overall, the computational evidence indicates the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.910621Binding0.3410.9260.750-5.796Likely Benign0.075Likely BenignLikely Benign0.273Likely Benign-0.20Neutral0.000Benign0.000Benign3.26Benign0.08Tolerated0.33090.4957102.214.03
c.2857C>A
P953T
2D
AIThe SynGAP1 missense variant P953T is predicted to be benign by all evaluated in silico tools. Consensus predictions from SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) classify the variant as Likely Benign. High‑accuracy predictors AlphaMissense‑Optimized also report a benign effect. Other pathogenicity predictors—REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM)—uniformly predict benign. No tools predict pathogenicity. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its stability impact remains unknown. The variant is not listed in ClinVar and has no entry in gnomAD, so no population frequency or clinical classification is available. Based on the unanimous benign predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.920633Binding0.4030.9260.750-6.646Likely Benign0.072Likely BenignLikely Benign0.075Likely Benign-0.80Neutral0.009Benign0.015Benign2.88Benign0.24Tolerated0.22610.60040-10.93.99
c.2857C>G
P953A
2D
AIThe SynGAP1 missense variant P953A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools that assess functional impact all converge on a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. No tool in the dataset indicates pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available, so they do not alter the overall assessment. Consequently, the variant is most likely benign based on the collective predictions, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.920633Binding0.4030.9260.750-4.879Likely Benign0.059Likely BenignLikely Benign0.082Likely Benign-0.98Neutral0.124Benign0.061Benign2.81Benign0.41Tolerated0.34760.52031-13.4-26.04
c.2857C>T
P953S
2D
AIThe SynGAP1 missense variant P953S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this trend: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign. Foldetta results are unavailable, so they do not influence the overall assessment. **Thus, the variant is most likely benign, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists.**

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.920633Binding0.4030.9260.750-5.430Likely Benign0.061Likely BenignLikely Benign0.073Likely Benign-0.35Neutral0.009Benign0.008Benign2.96Benign0.37Tolerated0.33590.51841-10.8-10.04
c.2858C>G
P953R
2D
AIThe SynGAP1 missense variant P953R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic outcome, creating a single discordant signal. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence supports a benign classification, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.920633Binding0.4030.9260.750-6.036Likely Benign0.174Likely BenignLikely Benign0.083Likely Benign-1.50Neutral0.611Possibly Damaging0.185Benign2.78Benign0.31Tolerated0.17710.45250-2-2.959.07
c.2858C>T
P953L
2D
AIThe SynGAP1 missense variant P953L is reported in gnomAD (variant ID 6‑33443410‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts it as pathogenic, representing a single dissenting opinion. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods points to a benign effect, and this conclusion is not contradicted by any ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.920633Binding0.4030.9260.7506-33443410-C-T116.82e-6-6.069Likely Benign0.079Likely BenignLikely Benign0.087Likely Benign-1.34Neutral0.611Possibly Damaging0.096Benign2.76Benign0.25Tolerated3.7750.27250.5778-3-35.416.04
c.285C>A
H95Q
2D
AIThe SynGAP1 missense variant H95Q is reported in gnomAD (ID 6‑33425893‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. In contrast, polyPhen‑2 HumDiv and SIFT predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates benign. No Foldetta stability analysis is available, so it does not influence the overall assessment. Overall, the preponderance of predictions indicates that H95Q is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.661982Disordered0.590542Binding0.3350.8750.6256-33425893-C-A16.20e-7-3.355Likely Benign0.084Likely BenignLikely Benign0.070Likely Benign-0.97Neutral0.633Possibly Damaging0.017Benign4.21Benign0.00Affected4.3210.15510.337503-0.3-9.01
c.285C>G
H95Q
2D
AIThe SynGAP1 missense variant H95Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates a likely benign outcome. In contrast, polyPhen‑2 HumDiv and SIFT predict pathogenicity, but these two tools are in minority. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.661982Disordered0.590542Binding0.3350.8750.625-3.355Likely Benign0.084Likely BenignLikely Benign0.070Likely Benign-0.97Neutral0.633Possibly Damaging0.017Benign4.21Benign0.00Affected4.3210.15510.337503-0.3-9.01
c.2860C>A
P954T
2D
AIThe SynGAP1 missense variant P954T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. The variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984159Disordered0.932268Binding0.4650.9260.750-5.657Likely Benign0.072Likely BenignLikely Benign0.089Likely Benign-0.77Neutral0.977Probably Damaging0.856Possibly Damaging2.79Benign0.48Tolerated0.18600.63240-10.93.99
c.2860C>G
P954A
2D
AIThe SynGAP1 missense variant P954A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. There is no ClinVar classification to contradict this conclusion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984159Disordered0.932268Binding0.4650.9260.750-4.985Likely Benign0.051Likely BenignLikely Benign0.072Likely Benign-0.21Neutral0.856Possibly Damaging0.652Possibly Damaging2.91Benign0.90Tolerated0.31030.55501-13.4-26.04
c.2861C>A
P954H
2D
AIThe SynGAP1 missense variant P954H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar or gnomAD entries—there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984159Disordered0.932268Binding0.4650.9260.750-3.670Likely Benign0.082Likely BenignLikely Benign0.098Likely Benign-0.50Neutral0.041Benign0.067Benign2.75Benign0.04Affected0.20540.47560-2-1.640.02
c.2861C>G
P954R
2D
AIThe SynGAP1 missense variant P954R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). In contrast, the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is also likely benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence indicates that P954R is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984159Disordered0.932268Binding0.4650.9260.750-6.329Likely Benign0.160Likely BenignLikely Benign0.097Likely Benign-1.19Neutral0.954Possibly Damaging0.826Possibly Damaging2.78Benign0.11Tolerated0.15480.39400-2-2.959.07
c.2861C>T
P954L
2D
AIThe SynGAP1 missense variant P954L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984159Disordered0.932268Binding0.4650.9260.750-5.607Likely Benign0.092Likely BenignLikely Benign0.097Likely Benign-0.43Neutral0.977Probably Damaging0.812Possibly Damaging2.78Benign0.55Tolerated0.23460.5867-3-35.416.04
c.2863T>A
S955T
2D
AIThe SynGAP1 missense variant S955T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for S955T, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.945325Binding0.3500.9240.750-4.717Likely Benign0.087Likely BenignLikely Benign0.070Likely Benign-0.96Neutral0.451Benign0.265Benign2.38Pathogenic0.00Affected0.21840.5927110.114.03
c.2863T>G
S955A
2D
AIThe SynGAP1 missense variant S955A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.945325Binding0.3500.9240.750-4.258Likely Benign0.068Likely BenignLikely Benign0.091Likely Benign-0.71Neutral0.004Benign0.006Benign2.41Pathogenic0.00Affected0.42620.5038112.6-16.00
c.2864C>A
S955Y
2D
AIThe SynGAP1 missense variant S955Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of predictions (six benign vs. four pathogenic) support a benign classification. There is no ClinVar entry to contradict this assessment, so the variant is most likely benign based on current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.945325Binding0.3500.9240.750-6.212Likely Benign0.216Likely BenignLikely Benign0.077Likely Benign-1.62Neutral0.977Probably Damaging0.721Possibly Damaging2.32Pathogenic0.00Affected0.13210.4932-3-2-0.576.10
c.2864C>G
S955C
2D
AIThe SynGAP1 missense variant S955C is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. The SGM Consensus, which takes a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (2 benign vs. 2 pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of available predictions (5 pathogenic vs. 4 benign) indicate a likely pathogenic impact. This conclusion is not contradicted by ClinVar status, as the variant has no existing ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.984871Disordered0.945325Binding0.3500.9240.750-8.675Likely Pathogenic0.117Likely BenignLikely Benign0.064Likely Benign-1.48Neutral0.977Probably Damaging0.796Possibly Damaging2.32Pathogenic0.00Affected0.17410.54700-13.316.06
c.2866T>A
S956T
2D
AIThe SynGAP1 missense variant S956T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign impact for S956T, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.957345Binding0.3640.9170.750-5.404Likely Benign0.097Likely BenignLikely Benign0.079Likely Benign-0.45Neutral0.369Benign0.159Benign2.00Pathogenic0.08Tolerated0.22440.5727110.114.03
c.2866T>C
S956P
2D
AIThe SynGAP1 missense variant S956P is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.957345Binding0.3640.9170.750-3.526Likely Benign0.082Likely BenignLikely Benign0.157Likely Benign-0.55Neutral0.000Benign0.001Benign1.95Pathogenic0.05Affected0.26700.53371-1-0.810.04
c.2866T>G
S956A
2D
AIThe SynGAP1 missense variant S956A is not reported in ClinVar or gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify it as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports it as likely benign. Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta stability analysis is unavailable. Overall, the collective evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.957345Binding0.3640.9170.750-4.468Likely Benign0.087Likely BenignLikely Benign0.111Likely Benign-0.47Neutral0.112Benign0.039Benign2.18Pathogenic0.13Tolerated0.42390.4838112.6-16.00
c.2867C>A
S956Y
2D
AIThe SynGAP1 missense variant S956Y is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion is consistent with the lack of ClinVar annotation. Thus, the variant is most likely benign, with no contradiction from ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.957345Binding0.3640.9170.750-4.920Likely Benign0.233Likely BenignLikely Benign0.085Likely Benign-0.90Neutral0.411Benign0.097Benign1.93Pathogenic0.22Tolerated0.14490.4932-3-2-0.576.10
c.2867C>G
S956C
2D
AIThe SynGAP1 missense variant S956C is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. The SGM Consensus, which takes a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (two benign vs. two pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of available predictions (five pathogenic vs. four benign) indicate a likely pathogenic impact. This conclusion is not contradicted by ClinVar status, as the variant has no existing ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.984871Disordered0.957345Binding0.3640.9170.750-9.292Likely Pathogenic0.108Likely BenignLikely Benign0.107Likely Benign-0.34Neutral0.938Possibly Damaging0.665Possibly Damaging1.94Pathogenic0.03Affected0.18330.54700-13.316.06
c.2867C>T
S956F
2D
AIThe SynGAP1 missense variant S956F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. The predictions do not contradict any ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.957345Binding0.3640.9170.750-6.654Likely Benign0.226Likely BenignLikely Benign0.101Likely Benign-1.04Neutral0.832Possibly Damaging0.398Benign1.93Pathogenic0.39Tolerated0.13150.4943-3-23.660.10
c.2869C>A
H957N
2D
AIThe SynGAP1 missense variant H957N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only FATHMM predicts a pathogenic outcome. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign status. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.968874Binding0.3620.9150.750-6.804Likely Benign0.090Likely BenignLikely Benign0.053Likely Benign-0.45Neutral0.144Benign0.058Benign2.45Pathogenic0.50Tolerated0.23430.378821-0.3-23.04
c.2869C>G
H957D
2D
AIThe SynGAP1 missense variant H957D is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are ESM1b and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (2 benign vs 2 pathogenic), and Foldetta results are unavailable. Overall, the majority of evidence (7 benign vs 2 pathogenic) supports a benign classification. This prediction is consistent with the lack of ClinVar annotation and gnomAD presence, indicating no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.985964Disordered0.968874Binding0.3620.9150.750-8.777Likely Pathogenic0.237Likely BenignLikely Benign0.149Likely Benign-0.77Neutral0.144Benign0.058Benign2.45Pathogenic0.44Tolerated0.26460.30661-1-0.3-22.05
c.2869C>T
H957Y
2D
AIThe SynGAP1 missense variant H957Y is listed in gnomAD (ID 6‑33443421‑C‑T) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which reports “Likely Benign.” Pathogenic predictions come from polyPhen‑2 HumDiv and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.968874Binding0.3620.9150.7506-33443421-C-T16.20e-7-6.631Likely Benign0.129Likely BenignLikely Benign0.099Likely Benign-1.00Neutral0.510Possibly Damaging0.147Benign2.42Pathogenic0.10Tolerated3.7750.15600.4906201.926.03
c.286G>C
G96R
2D
AIThe SynGAP1 missense variant G96R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for G96R, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.657645Disordered0.599491Binding0.3350.8710.625-3.872Likely Benign0.349AmbiguousLikely Benign0.059Likely Benign-0.91Neutral0.687Possibly Damaging0.062Benign4.19Benign0.00Affected0.13000.5031-3-2-4.199.14
c.286G>T
G96C
2D
AIThe SynGAP1 missense variant G96C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The high‑accuracy consensus methods give a benign verdict: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” No result is available from Foldetta, so its folding‑stability assessment is not considered. Overall, the majority of evidence points to a benign impact, and this is consistent with the lack of any ClinVar classification. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.657645Disordered0.599491Binding0.3350.8710.625-5.140Likely Benign0.087Likely BenignLikely Benign0.112Likely Benign-1.87Neutral0.981Probably Damaging0.216Benign4.12Benign0.00Affected0.16450.4142-3-32.946.09
c.2870A>C
H957P
2D
AIThe SynGAP1 H957P missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and FATHMM. The high‑accuracy consensus (SGM‑Consensus) is derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yielding a Likely Benign classification (3 benign vs. 1 pathogenic). AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.968874Binding0.3620.9150.750-6.347Likely Benign0.061Likely BenignLikely Benign0.244Likely Benign-0.61Neutral0.453Possibly Damaging0.105Benign2.42Pathogenic0.13Tolerated0.23000.47010-21.6-40.02
c.2870A>G
H957R
2D
AIThe SynGAP1 missense variant H957R is catalogued in gnomAD (ID 6‑33443422‑A‑G) but has no ClinVar entry. Functional prediction tools uniformly classify it as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign or tolerated outcomes. No tool predicts pathogenicity. Grouping by consensus, all listed predictors fall into the benign category, with no opposing pathogenic calls. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta results are unavailable, so they do not influence the assessment. Overall, the evidence strongly supports a benign classification for H957R, and this conclusion does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.968874Binding0.3620.9150.7506-33443422-A-G16.20e-7-6.723Likely Benign0.183Likely BenignLikely Benign0.105Likely Benign-1.31Neutral0.144Benign0.078Benign2.58Benign0.32Tolerated3.7750.24100.361002-1.319.05
c.2870A>T
H957L
2D
AIThe SynGAP1 missense variant H957L is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only FATHMM predicts a pathogenic outcome. When predictions are grouped by consensus, the benign group contains eight tools, whereas the pathogenic group contains only FATHMM. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a Likely Benign result. Foldetta, a protein‑folding stability method, has no available output for this variant. Overall, the preponderance of evidence indicates that H957L is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.968874Binding0.3620.9150.750-6.598Likely Benign0.090Likely BenignLikely Benign0.296Likely Benign-0.38Neutral0.000Benign0.000Benign2.44Pathogenic0.09Tolerated0.15250.5516-2-37.0-23.98
c.2871T>A
H957Q
2D
AIThe SynGAP1 missense variant H957Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is not contradicted by any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.968874Binding0.3620.9150.750-6.304Likely Benign0.130Likely BenignLikely Benign0.113Likely Benign-0.87Neutral0.255Benign0.105Benign2.54Benign0.56Tolerated0.22270.411430-0.3-9.01
c.2871T>G
H957Q
2D
AIThe SynGAP1 missense variant H957Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is not contradicted by any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.968874Binding0.3620.9150.750-6.304Likely Benign0.130Likely BenignLikely Benign0.113Likely Benign-0.87Neutral0.255Benign0.105Benign2.54Benign0.56Tolerated0.22270.411430-0.3-9.01
c.2872C>A
H958N
2D
AIThe SynGAP1 missense variant H958N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.976011Binding0.3710.9130.750-8.644Likely Pathogenic0.097Likely BenignLikely Benign0.110Likely Benign-0.56Neutral0.836Possibly Damaging0.232Benign4.17Benign1.00Tolerated0.23580.363821-0.3-23.04
c.2872C>G
H958D
2D
AIThe SynGAP1 missense variant H958D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and ESM1b—suggest a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.976011Binding0.3710.9130.750-11.494Likely Pathogenic0.227Likely BenignLikely Benign0.200Likely Benign-0.55Neutral0.925Possibly Damaging0.232Benign4.16Benign0.55Tolerated0.27320.28661-1-0.3-22.05
c.2872C>T
H958Y
2D
AIThe SynGAP1 missense variant H958Y is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and ESM1b—suggest a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not conflict with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.976011Binding0.3710.9130.750-8.393Likely Pathogenic0.132Likely BenignLikely Benign0.129Likely Benign-1.03Neutral0.836Possibly Damaging0.232Benign4.14Benign0.06Tolerated0.17920.4706021.926.03
c.2873A>G
H958R
2D
AIThe SynGAP1 missense variant H958R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.976011Binding0.3710.9130.750-9.188Likely Pathogenic0.169Likely BenignLikely Benign0.134Likely Benign-1.29Neutral0.836Possibly Damaging0.232Benign4.17Benign0.09Tolerated0.24400.341020-1.319.05
c.2873A>T
H958L
2D
AIThe SynGAP1 missense variant H958L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only two tools, SIFT and ESM1b, predict a pathogenic outcome. When the high‑accuracy consensus is considered, the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a likely benign verdict, and AlphaMissense‑Optimized also reports benign. Foldetta predictions are unavailable. Overall, the majority of evidence supports a benign interpretation, and this is consistent with the lack of ClinVar annotation. Thus, the variant is most likely benign and does not contradict existing ClinVar data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.976011Binding0.3710.9130.750-8.422Likely Pathogenic0.087Likely BenignLikely Benign0.181Likely Benign-1.28Neutral0.001Benign0.001Benign4.25Benign0.03Affected0.17230.5338-2-37.0-23.98
c.2874C>A
H958Q
2D
AIThe SynGAP1 missense variant H958Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. The predictions do not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.976011Binding0.3710.9130.750-8.625Likely Pathogenic0.117Likely BenignLikely Benign0.144Likely Benign-0.97Neutral0.925Possibly Damaging0.316Benign4.18Benign0.11Tolerated0.22810.373630-0.3-9.01
c.2874C>G
H958Q
2D
AIThe SynGAP1 missense variant H958Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. The predictions do not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.976011Binding0.3710.9130.750-8.625Likely Pathogenic0.117Likely BenignLikely Benign0.144Likely Benign-0.97Neutral0.925Possibly Damaging0.316Benign4.18Benign0.11Tolerated0.22810.373630-0.3-9.01
c.2875C>A
H959N
2D
AIThe SynGAP1 missense variant H959N is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only ESM1b predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from multiple independent predictors and high‑accuracy tools indicates that H959N is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.980566Binding0.3330.9050.750-8.811Likely Pathogenic0.104Likely BenignLikely Benign0.115Likely Benign-0.10Neutral0.144Benign0.058Benign4.15Benign0.21Tolerated0.22980.383821-0.3-23.04
c.2875C>G
H959D
2D
AIThe SynGAP1 missense variant H959D is listed in gnomAD (ID 6‑33443427‑C‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, resolves to “Likely Benign” (three benign votes versus one pathogenic). High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar status (none reported). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.980566Binding0.3330.9050.7506-33443427-C-G16.20e-7-12.060Likely Pathogenic0.235Likely BenignLikely Benign0.176Likely Benign-0.73Neutral0.144Benign0.058Benign4.14Benign0.29Tolerated3.7750.25860.3066-11-0.3-22.05
c.2875C>T
H959Y
2D
AIThe SynGAP1 missense variant H959Y is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate a tolerated change, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also classifies it as Likely Benign. In contrast, polyPhen‑2 HumDiv, SIFT, and ESM1b predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect for H959Y, and this conclusion does not conflict with ClinVar, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.980566Binding0.3330.9050.750-8.367Likely Pathogenic0.146Likely BenignLikely Benign0.140Likely Benign-1.09Neutral0.510Possibly Damaging0.147Benign4.09Benign0.05Affected0.16720.4906021.926.03
c.2876A>C
H959P
2D
AIThe SynGAP1 missense variant H959P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.980566Binding0.3330.9050.750-8.902Likely Pathogenic0.070Likely BenignLikely Benign0.232Likely Benign-0.61Neutral0.453Possibly Damaging0.105Benign4.14Benign0.38Tolerated0.22840.49010-21.6-40.02
c.2876A>G
H959R
2D
AIThe SynGAP1 missense variant H959R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as likely benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.980566Binding0.3330.9050.750-9.459Likely Pathogenic0.182Likely BenignLikely Benign0.162Likely Benign-1.11Neutral0.144Benign0.078Benign4.14Benign0.15Tolerated0.24160.361020-1.319.05
c.2876A>T
H959L
2D
AIThe SynGAP1 missense variant H959L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as likely benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that H959L is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.980566Binding0.3330.9050.750-8.515Likely Pathogenic0.100Likely BenignLikely Benign0.236Likely Benign-1.38Neutral0.000Benign0.000Benign4.14Benign0.09Tolerated0.16980.5538-2-37.0-23.98
c.2877C>A
H959Q
2D
AIThe SynGAP1 missense variant H959Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports it as likely benign. Only ESM1b predicts a pathogenic outcome, representing the sole discordant signal. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that H959Q is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.980566Binding0.3330.9050.750-8.657Likely Pathogenic0.126Likely BenignLikely Benign0.182Likely Benign-0.77Neutral0.255Benign0.105Benign4.15Benign0.10Tolerated0.22640.393630-0.3-9.01
c.2877C>G
H959Q
2D
AIThe SynGAP1 missense variant H959Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign, while the single pathogenic prediction comes from ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus itself is benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that H959Q is most likely benign, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.980566Binding0.3330.9050.750-8.657Likely Pathogenic0.126Likely BenignLikely Benign0.182Likely Benign-0.77Neutral0.255Benign0.105Benign4.15Benign0.10Tolerated0.22640.393630-0.3-9.01
c.2878C>A
H960N
2D
AIThe SynGAP1 missense variant H960N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987911Disordered0.983385Binding0.3800.9010.750-8.822Likely Pathogenic0.101Likely BenignLikely Benign0.130Likely Benign-0.57Neutral0.494Possibly Damaging0.129Benign4.19Benign0.40Tolerated0.21370.369521-0.3-23.04
c.2878C>G
H960D
2D
AIThe SynGAP1 missense variant H960D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. The predictions do not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987911Disordered0.983385Binding0.3800.9010.750-12.235Likely Pathogenic0.243Likely BenignLikely Benign0.147Likely Benign-1.09Neutral0.494Possibly Damaging0.170Benign4.19Benign0.31Tolerated0.25040.29231-1-0.3-22.05
c.2878C>T
H960Y
2D
AIThe SynGAP1 missense variant H960Y is reported in gnomAD (ID 6‑33443430‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only two tools predict pathogenicity—polyPhen‑2 HumDiv and ESM1b—while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports likely benign; Foldetta results are unavailable. Overall, the consensus of the majority of prediction algorithms and the high‑accuracy tools points to a benign effect. This conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987911Disordered0.983385Binding0.3800.9010.7506-33443430-C-T16.20e-7-8.181Likely Pathogenic0.158Likely BenignLikely Benign0.097Likely Benign-1.25Neutral0.748Possibly Damaging0.232Benign4.13Benign0.21Tolerated3.7750.14460.4963201.926.03
c.2879A>C
H960P
2D
AIThe SynGAP1 missense variant H960P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987911Disordered0.983385Binding0.3800.9010.750-8.672Likely Pathogenic0.064Likely BenignLikely Benign0.119Likely Benign-0.95Neutral0.494Possibly Damaging0.170Benign4.18Benign0.28Tolerated0.21570.49010-21.6-40.02
c.2879A>G
H960R
2D
AIThe SynGAP1 missense variant H960R is reported in gnomAD (ID 6‑33443431‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only two tools predict pathogenicity—polyPhen‑2 HumDiv and ESM1b—while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports likely benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987911Disordered0.983385Binding0.3800.9010.7506-33443431-A-G16.20e-7-9.238Likely Pathogenic0.192Likely BenignLikely Benign0.075Likely Benign-1.10Neutral0.494Possibly Damaging0.170Benign4.19Benign0.25Tolerated3.7750.22370.366702-1.319.05
c.2879A>T
H960L
2D
AIThe SynGAP1 missense variant H960L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic prediction comes from ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987911Disordered0.983385Binding0.3800.9010.750-8.386Likely Pathogenic0.108Likely BenignLikely Benign0.130Likely Benign-1.30Neutral0.174Benign0.043Benign4.17Benign0.33Tolerated0.14650.5595-2-37.0-23.98
c.287G>A
G96D
2D
AIThe SynGAP1 missense variant G96D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. The variant is most likely benign, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.657645Disordered0.599491Binding0.3350.8710.625-3.699Likely Benign0.249Likely BenignLikely Benign0.099Likely Benign-0.95Neutral0.000Benign0.000Benign4.18Benign0.00Affected0.22830.31501-1-3.158.04
c.287G>C
G96A
2D
AIThe SynGAP1 missense variant G96A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.657645Disordered0.599491Binding0.3350.8710.625-3.669Likely Benign0.066Likely BenignLikely Benign0.064Likely Benign-1.00Neutral0.092Benign0.007Benign4.23Benign0.00Affected0.40980.4212102.214.03
c.287G>T
G96V
2D
AIThe SynGAP1 missense variant G96V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. The variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.657645Disordered0.599491Binding0.3350.8710.625-4.266Likely Benign0.078Likely BenignLikely Benign0.109Likely Benign-1.43Neutral0.334Benign0.029Benign4.18Benign0.00Affected0.15750.3833-1-34.642.08
c.2880C>A
H960Q
2D
AIThe SynGAP1 missense variant H960Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. The predictions do not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987911Disordered0.983385Binding0.3800.9010.750-8.551Likely Pathogenic0.124Likely BenignLikely Benign0.109Likely Benign-0.79Neutral0.748Possibly Damaging0.170Benign4.20Benign0.21Tolerated0.20450.399330-0.3-9.01
c.2880C>G
H960Q
2D
AIThe SynGAP1 missense variant H960Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987911Disordered0.983385Binding0.3800.9010.750-8.551Likely Pathogenic0.124Likely BenignLikely Benign0.109Likely Benign-0.79Neutral0.748Possibly Damaging0.170Benign4.20Benign0.21Tolerated0.20450.399330-0.3-9.01
c.2881C>A
H961N
2D
AIThe SynGAP1 missense variant H961N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as likely benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that H961N is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750-8.561Likely Pathogenic0.096Likely BenignLikely Benign0.084Likely Benign-0.32Neutral0.069Benign0.036Benign4.17Benign0.81Tolerated0.20740.369521-0.3-23.04
c.2881C>G
H961D
2D
AIThe SynGAP1 missense variant H961D is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750-12.522Likely Pathogenic0.224Likely BenignLikely Benign0.115Likely Benign-0.98Neutral0.069Benign0.036Benign4.19Benign0.09Tolerated0.24870.27231-1-0.3-22.05
c.2882A>C
H961P
2D
AIThe SynGAP1 missense variant H961P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign, while only SIFT and ESM1b predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a Likely Benign verdict (3 benign vs. 1 pathogenic). High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Consequently, the collective evidence indicates that H961P is most likely benign, and this conclusion is not in conflict with ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750-8.434Likely Pathogenic0.071Likely BenignLikely Benign0.210Likely Benign-0.58Neutral0.000Benign0.000Benign4.15Benign0.02Affected0.20610.47010-21.6-40.02
c.2882A>G
H961R
2D
AIThe SynGAP1 missense variant H961R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b. The SGM‑Consensus, which is a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign (3 benign vs. 1 pathogenic). High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750-9.258Likely Pathogenic0.189Likely BenignLikely Benign0.101Likely Benign-0.90Neutral0.144Benign0.078Benign4.16Benign0.02Affected0.22010.326720-1.319.05
c.2882A>T
H961L
2D
AIThe SynGAP1 missense variant H961L is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only SIFT and ESM1b predict pathogenicity, but these are outliers among the consensus. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as likely benign. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, SGM‑Consensus is benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Overall, the preponderance of evidence indicates the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750-8.547Likely Pathogenic0.109Likely BenignLikely Benign0.155Likely Benign-1.21Neutral0.144Benign0.078Benign4.13Benign0.01Affected0.14650.5344-2-37.0-23.98
c.2883C>A
H961Q
2D
AIThe SynGAP1 missense variant H961Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only SIFT and ESM1b predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict (3 benign vs. 1 pathogenic). High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750-8.368Likely Pathogenic0.118Likely BenignLikely Benign0.088Likely Benign-0.49Neutral0.255Benign0.105Benign4.17Benign0.02Affected0.20220.374330-0.3-9.01
c.2883C>G
H961Q
2D
AIThe SynGAP1 missense variant H961Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT and ESM1b predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a majority‑benign vote and is reported as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the available predictions indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750-8.368Likely Pathogenic0.118Likely BenignLikely Benign0.088Likely Benign-0.49Neutral0.255Benign0.105Benign4.17Benign0.02Affected0.20220.374330-0.3-9.01
c.2884C>A
H962N
2D
AIThe SynGAP1 missense variant H962N is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.984483Binding0.3690.8860.750-8.481Likely Pathogenic0.098Likely BenignLikely Benign0.058Likely Benign-0.61Neutral0.174Benign0.045Benign4.18Benign0.24Tolerated0.19570.321621-0.3-23.04
c.2884C>G
H962D
2D
AIThe SynGAP1 missense variant H962D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect. There is no ClinVar entry to contradict this conclusion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.984483Binding0.3690.8860.750-12.472Likely Pathogenic0.237Likely BenignLikely Benign0.178Likely Benign-1.08Neutral0.001Benign0.002Benign4.20Benign0.20Tolerated0.24020.26431-1-0.3-22.05
c.2884C>T
H962Y
2D
AIThe SynGAP1 missense variant H962Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as Likely Benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for H962Y, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.984483Binding0.3690.8860.750-7.735In-Between0.167Likely BenignLikely Benign0.093Likely Benign-1.27Neutral0.878Possibly Damaging0.232Benign4.12Benign0.03Affected0.17410.4411021.926.03
c.2885A>C
H962P
2D
AIThe SynGAP1 missense variant H962P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and ESM1b—suggest a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.984483Binding0.3690.8860.750-8.419Likely Pathogenic0.066Likely BenignLikely Benign0.197Likely Benign-0.94Neutral0.748Possibly Damaging0.170Benign4.16Benign0.07Tolerated0.20110.43520-21.6-40.02
c.2885A>G
H962R
2D
AIThe SynGAP1 missense variant H962R is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” status. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion is consistent with the lack of any ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.984483Binding0.3690.8860.750-9.166Likely Pathogenic0.212Likely BenignLikely Benign0.117Likely Benign-1.04Neutral0.325Benign0.129Benign4.18Benign0.07Tolerated0.22760.333720-1.319.05
c.2885A>T
H962L
2D
AIThe SynGAP1 missense variant H962L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for H962L, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.984483Binding0.3690.8860.750-8.478Likely Pathogenic0.108Likely BenignLikely Benign0.151Likely Benign-1.49Neutral0.494Possibly Damaging0.170Benign4.15Benign0.03Affected0.17380.5487-2-37.0-23.98
c.2886C>A
H962Q
2D
AIThe SynGAP1 missense variant H962Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.984483Binding0.3690.8860.750-8.161Likely Pathogenic0.130Likely BenignLikely Benign0.114Likely Benign-1.04Neutral0.325Benign0.045Benign4.19Benign0.06Tolerated0.19430.384430-0.3-9.01
c.2886C>G
H962Q
2D
AIThe SynGAP1 missense variant H962Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect. There is no ClinVar entry to contradict this conclusion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.984483Binding0.3690.8860.750-8.161Likely Pathogenic0.130Likely BenignLikely Benign0.114Likely Benign-1.04Neutral0.325Benign0.045Benign4.19Benign0.06Tolerated0.19430.384430-0.3-9.01
c.2887C>A
H963N
2D
AIThe SynGAP1 missense variant H963N is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical databases.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.983973Binding0.3250.8860.750-8.274Likely Pathogenic0.099Likely BenignLikely Benign0.089Likely Benign-0.21Neutral0.369Benign0.120Benign4.18Benign0.16Tolerated0.20940.359621-0.3-23.04
c.2887C>G
H963D
2D
AIThe SynGAP1 missense variant H963D is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic prediction comes from ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” status. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates benign; Foldetta results are not available. Overall, the consensus of the majority of tools and the high‑accuracy predictions point to a benign impact for H963D, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.983973Binding0.3250.8860.750-12.082Likely Pathogenic0.204Likely BenignLikely Benign0.167Likely Benign-0.81Neutral0.369Benign0.159Benign4.16Benign0.46Tolerated0.24820.30231-1-0.3-22.05
c.2887C>T
H963Y
2D
AIThe SynGAP1 missense variant H963Y is catalogued in gnomAD (ID 6‑33443439‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all indicate a benign or likely benign outcome. Only polyPhen‑2 HumDiv predicts a pathogenic effect, while ESM1b remains uncertain. High‑accuracy assessments confirm this trend: AlphaMissense‑Optimized reports benign, and the SGM‑Consensus likewise classifies the variant as likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.983973Binding0.3250.8860.7506-33443439-C-T16.20e-7-7.557In-Between0.158Likely BenignLikely Benign0.105Likely Benign-1.13Neutral0.812Possibly Damaging0.298Benign4.09Benign0.10Tolerated3.7750.16270.4464201.926.03
c.2888A>C
H963P
2D
AIThe SynGAP1 missense variant H963P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only ESM1b predicts a pathogenic outcome, while the consensus score from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized reports benign, and the SGM Consensus also indicates Likely Benign; Foldetta data are not available. Overall, the majority of evidence points to a benign effect, and this conclusion is not in conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.983973Binding0.3250.8860.750-8.158Likely Pathogenic0.074Likely BenignLikely Benign0.223Likely Benign-1.10Neutral0.000Benign0.001Benign4.10Benign0.14Tolerated0.21010.44870-21.6-40.02
c.2888A>T
H963L
2D
AIThe SynGAP1 missense variant H963L is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as likely benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized indicates benign, and the SGM‑Consensus likewise suggests a benign effect; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for H963L, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.983973Binding0.3250.8860.750-8.110Likely Pathogenic0.109Likely BenignLikely Benign0.172Likely Benign-1.58Neutral0.224Benign0.091Benign4.13Benign0.43Tolerated0.16260.5680-2-37.0-23.98
c.2889T>A
H963Q
2D
AIThe SynGAP1 missense variant H963Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the only uncertain result comes from ESM1b. The high‑accuracy consensus methods also support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the evidence overwhelmingly indicates that H963Q is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.983973Binding0.3250.8860.750-7.798In-Between0.116Likely BenignLikely Benign0.104Likely Benign-0.75Neutral0.411Benign0.132Benign4.17Benign0.29Tolerated0.21120.397930-0.3-9.01
c.2889T>G
H963Q
2D
AIThe SynGAP1 missense variant H963Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity; the only uncertain result comes from ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the collective evidence strongly supports a benign classification, and there is no ClinVar annotation to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.983973Binding0.3250.8860.750-7.798In-Between0.116Likely BenignLikely Benign0.104Likely Benign-0.75Neutral0.411Benign0.132Benign4.17Benign0.29Tolerated0.21120.397930-0.3-9.01
c.2890C>A
H964N
2D
AIThe SynGAP1 missense variant H964N is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-8.073Likely Pathogenic0.084Likely BenignLikely Benign0.098Likely Benign-0.30Neutral0.000Benign0.000Benign4.18Benign0.64Tolerated0.19880.349521-0.3-23.04
c.2890C>G
H964D
2D
AIThe SynGAP1 missense variant H964D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic prediction comes from ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-11.061Likely Pathogenic0.207Likely BenignLikely Benign0.124Likely Benign-0.45Neutral0.000Benign0.000Benign4.18Benign0.24Tolerated0.23130.29231-1-0.3-22.05
c.2890C>T
H964Y
2D
AIThe SynGAP1 missense variant H964Y is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. Only SIFT predicts a pathogenic outcome, and ESM1b remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized predicts benign, SGM‑Consensus indicates likely benign, and the Foldetta stability analysis is unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-7.385In-Between0.139Likely BenignLikely Benign0.069Likely Benign-1.13Neutral0.000Benign0.001Benign4.11Benign0.02Affected0.14220.4363021.926.03
c.2891A>C
H964P
2D
AIThe SynGAP1 missense variant H964P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign, while the only pathogenic call comes from SIFT. ESM1b is uncertain, and the SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign consensus. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates likely benign. Foldetta stability analysis is unavailable. Overall, the collective evidence points to a benign impact for H964P, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-7.466In-Between0.063Likely BenignLikely Benign0.156Likely Benign-0.34Neutral0.000Benign0.000Benign4.12Benign0.04Affected0.19780.43010-21.6-40.02
c.2891A>G
H964R
2D
AIThe SynGAP1 missense variant H964R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b. The SGM‑Consensus, which is a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign (3 benign vs. 1 pathogenic). High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-8.275Likely Pathogenic0.163Likely BenignLikely Benign0.129Likely Benign-0.68Neutral0.000Benign0.000Benign4.19Benign0.05Affected0.22370.346720-1.319.05
c.2891A>T
H964L
2D
AIThe SynGAP1 missense variant H964L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. Only SIFT predicts a pathogenic outcome, and ESM1b remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) indicates likely benign; Foldetta stability analysis is unavailable. Overall, the preponderance of evidence points to a benign effect, and this conclusion does not conflict with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-7.568In-Between0.092Likely BenignLikely Benign0.129Likely Benign-1.20Neutral0.000Benign0.000Benign4.15Benign0.02Affected0.14090.5195-2-37.0-23.98
c.2892C>A
H964Q
2D
AIThe SynGAP1 missense variant H964Q is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. The only tool with an uncertain call is ESM1b, and no pathogenic predictions are reported. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments further support this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-7.279In-Between0.102Likely BenignLikely Benign0.058Likely Benign-0.38Neutral0.000Benign0.000Benign4.18Benign0.07Tolerated0.19690.359330-0.3-9.01
c.2892C>G
H964Q
2D
AIThe SynGAP1 missense variant H964Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the only uncertain result comes from ESM1b. The high‑accuracy consensus methods also support a benign classification: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the evidence overwhelmingly indicates that H964Q is most likely benign, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-7.279In-Between0.102Likely BenignLikely Benign0.058Likely Benign-0.38Neutral0.000Benign0.000Benign4.18Benign0.07Tolerated0.19690.359330-0.3-9.01
c.2893C>A
H965N
2D
AIThe SynGAP1 missense variant H965N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Across the available in‑silico predictors, the majority (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized) uniformly predict a benign effect, while no tool predicts pathogenicity. ESM1b is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.978700Binding0.3420.8820.750-7.605In-Between0.082Likely BenignLikely Benign0.076Likely Benign-0.50Neutral0.000Benign0.001Benign4.09Benign0.80Tolerated0.23600.383821-0.3-23.04
c.2893C>G
H965D
2D
AIThe SynGAP1 missense variant H965D is reported in gnomAD (6‑33443445‑C‑G) and has no ClinVar entry. Consensus from most in silico predictors—REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—classifies the change as benign, while only the ESM1b model flags it as pathogenic. High‑accuracy assessments reinforce the benign prediction: AlphaMissense‑Optimized returns a benign score, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, did not provide a result for this residue, so its status is unavailable. Overall, the preponderance of evidence indicates that H965D is most likely benign, and this assessment does not contradict any ClinVar classification because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.978700Binding0.3420.8820.7506-33443445-C-G16.20e-7-9.827Likely Pathogenic0.192Likely BenignLikely Benign0.147Likely Benign-0.94Neutral0.007Benign0.018Benign4.09Benign0.62Tolerated3.7750.26970.3066-11-0.3-22.05
c.2893C>T
H965Y
2D
AIThe SynGAP1 missense variant H965Y is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the substitution as tolerated. The consensus score from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” No tool predicts pathogenicity, and the single uncertain result from ESM1b does not alter the overall benign consensus. High‑accuracy methods corroborate this: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and Foldetta data are unavailable. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.978700Binding0.3420.8820.750-7.121In-Between0.133Likely BenignLikely Benign0.092Likely Benign-1.02Neutral0.327Benign0.147Benign4.03Benign0.25Tolerated0.15820.4906021.926.03
c.2894A>C
H965P
2D
AIThe SynGAP1 missense variant H965P is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. No tool predicts pathogenicity. The high‑accuracy consensus methods also support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are unavailable. Overall, the variant is most likely benign, and this prediction does not contradict any ClinVar status, as no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.978700Binding0.3420.8820.750-6.835Likely Benign0.059Likely BenignLikely Benign0.245Likely Benign-0.69Neutral0.000Benign0.001Benign4.06Benign0.19Tolerated0.23420.49010-21.6-40.02
c.2894A>G
H965R
2D
AIThe SynGAP1 missense variant H965R is catalogued in gnomAD (ID 6‑33443446‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all classify the change as benign or likely benign. No tool predicts pathogenicity; ESM1b is uncertain but does not contradict the benign consensus. High‑accuracy assessments confirm this view: AlphaMissense‑Optimized reports a benign effect, and the SGM‑Consensus likewise indicates a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no reported result for this variant, so it does not influence the assessment. Overall, the available predictions strongly suggest that H965R is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.978700Binding0.3420.8820.7506-33443446-A-G16.20e-7-7.056In-Between0.156Likely BenignLikely Benign0.104Likely Benign-0.88Neutral0.065Benign0.049Benign4.08Benign0.38Tolerated3.7750.23940.361002-1.319.05
c.2894A>T
H965L
2D
AIThe SynGAP1 missense variant H965L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect. Benign predictors include REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; no tool in the dataset returned a pathogenic prediction. Consensus predictors such as SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) classify the variant as Likely Benign. High‑accuracy methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus is Likely Benign; Foldetta results are not available. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.978700Binding0.3420.8820.750-6.708Likely Benign0.091Likely BenignLikely Benign0.128Likely Benign-1.66Neutral0.033Benign0.018Benign4.06Benign1.00Tolerated0.16060.5338-2-37.0-23.98
c.2895C>A
H965Q
2D
AIThe SynGAP1 missense variant H965Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.978700Binding0.3420.8820.750-6.447Likely Benign0.101Likely BenignLikely Benign0.042Likely Benign-0.71Neutral0.138Benign0.105Benign4.09Benign0.28Tolerated0.22570.393630-0.3-9.01
c.2895C>G
H965Q
2D
AIThe SynGAP1 missense variant H965Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect. Consensus predictors such as SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) classify the variant as Likely Benign. Individual algorithms—REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—all predict a benign outcome. No tool in the dataset returned a pathogenic prediction. High‑accuracy methods: AlphaMissense‑Optimized is benign; SGM‑Consensus is Likely Benign; Foldetta results are not available. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.978700Binding0.3420.8820.750-6.447Likely Benign0.101Likely BenignLikely Benign0.043Likely Benign-0.71Neutral0.138Benign0.105Benign4.09Benign0.28Tolerated0.22570.393630-0.3-9.01
c.2896C>A
H966N
2D
AIThe SynGAP1 missense variant H966N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while ESM1b is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates that H966N is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.750-7.579In-Between0.085Likely BenignLikely Benign0.094Likely Benign-0.84Neutral0.748Possibly Damaging0.232Benign4.06Benign0.89Tolerated0.21530.378821-0.3-23.04
c.2896C>G
H966D
2D
AIThe SynGAP1 missense variant H966D is listed in gnomAD (ID 6‑33443448‑C‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all classify the change as benign or likely benign. Only two tools predict a damaging outcome—polyPhen‑2 HumDiv and ESM1b—which are outliers relative to the consensus. High‑accuracy assessments confirm the benign trend: AlphaMissense‑Optimized reports a benign effect, and the SGM‑Consensus also indicates a likely benign status. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of predictions support a benign impact, and this is consistent with the absence of a pathogenic ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.7506-33443448-C-G16.20e-7-8.426Likely Pathogenic0.201Likely BenignLikely Benign0.182Likely Benign-1.09Neutral0.494Possibly Damaging0.170Benign4.05Benign0.93Tolerated4.3220.25040.3066-11-0.3-22.05
c.2896C>T
H966Y
2D
AIThe SynGAP1 missense variant H966Y is catalogued in gnomAD (6‑33443448‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) all classify the change as benign or likely benign. Only polyPhen‑2 HumDiv reports a pathogenic prediction, representing the sole discordant signal. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates likely benign. No Foldetta stability data are available, so folding‑stability evidence is inconclusive. Overall, the preponderance of predictions supports a benign classification for H966Y, and this conclusion is not contradicted by any ClinVar status (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.7506-33443448-C-T-6.847Likely Benign0.126Likely BenignLikely Benign0.106Likely Benign-1.27Neutral0.878Possibly Damaging0.232Benign4.01Benign0.23Tolerated4.3220.14650.4506201.926.03
c.2897A>C
H966P
2D
AIThe SynGAP1 missense variant H966P is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.750-5.831Likely Benign0.064Likely BenignLikely Benign0.279Likely Benign-0.27Neutral0.001Benign0.001Benign4.01Benign0.72Tolerated0.21680.43010-21.6-40.02
c.2897A>G
H966R
2D
AIThe SynGAP1 missense variant H966R is reported in gnomAD (ID 6‑33443449‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv flags it as pathogenic, creating a single discordant call. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods indicates that H966R is most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.7506-33443449-A-G-5.474Likely Benign0.157Likely BenignLikely Benign0.172Likely Benign-0.71Neutral0.494Possibly Damaging0.170Benign4.06Benign0.69Tolerated4.3220.21980.341002-1.319.05
c.2897A>T
H966L
2D
AIThe SynGAP1 missense variant H966L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. No pathogenic predictions are present among the evaluated algorithms. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) reports likely benign. Foldetta results are not available for this variant. Based on the collective evidence, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.750-6.119Likely Benign0.095Likely BenignLikely Benign0.183Likely Benign-1.74Neutral0.174Benign0.062Benign4.05Benign0.35Tolerated0.15140.5316-2-37.0-23.98
c.2898C>A
H966Q
2D
AIThe SynGAP1 missense variant H966Q is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that H966Q is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.750-5.662Likely Benign0.100Likely BenignLikely Benign0.113Likely Benign-0.66Neutral0.748Possibly Damaging0.232Benign4.06Benign0.45Tolerated0.20580.391430-0.3-9.01
c.2898C>G
H966Q
2D
AIThe SynGAP1 missense variant H966Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.750-5.662Likely Benign0.100Likely BenignLikely Benign0.113Likely Benign-0.66Neutral0.748Possibly Damaging0.232Benign4.06Benign0.45Tolerated0.20580.391430-0.3-9.01
c.2899C>G
R967G
2D
AIThe SynGAP1 missense variant R967G is reported in gnomAD (ID 6‑33443451‑C‑G) and has no ClinVar entry. All evaluated in silico predictors classify it as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are unavailable. Based on the unanimous benign predictions and absence of a ClinVar pathogenic claim, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.974374Disordered0.969686Binding0.3400.8880.7506-33443451-C-G16.20e-7-2.214Likely Benign0.098Likely BenignLikely Benign0.279Likely Benign-0.93Neutral0.005Benign0.007Benign4.17Benign0.18Tolerated4.3220.31870.4070-2-34.1-99.14
c.289G>A
E97K
2D
AIThe SynGAP1 missense variant E97K is catalogued in gnomAD (ID 6‑33425897‑G‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from both general and high‑accuracy predictors points to a benign effect. This conclusion is not contradicted by ClinVar, as no ClinVar classification exists for E97K.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.609018Binding0.3400.8670.6256-33425897-G-A16.20e-7-4.972Likely Benign0.643Likely PathogenicLikely Benign0.139Likely Benign-0.30Neutral0.976Probably Damaging0.651Possibly Damaging4.16Benign0.00Affected4.3210.27090.790810-0.4-0.94
c.289G>C
E97Q
2D
AIThe SynGAP1 missense variant E97Q is reported in gnomAD (ID 6‑33425897‑G‑C) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus itself is Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence from both consensus and high‑accuracy predictors indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.609018Binding0.3400.8670.6256-33425897-G-C21.24e-6-3.917Likely Benign0.300Likely BenignLikely Benign0.113Likely Benign-0.32Neutral0.978Probably Damaging0.832Possibly Damaging4.13Benign0.00Affected4.3210.15070.7874220.0-0.98
c.28C>G
R10G
2D
AIThe SynGAP1 missense variant R10G is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized scores the variant as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” No Foldetta stability prediction is available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.513657Binding0.3300.9150.625-3.931Likely Benign0.124Likely BenignLikely Benign0.175Likely Benign0.48Neutral0.058Benign0.009Benign4.15Benign0.00Affected0.37960.4015-3-24.1-99.14
c.2900G>C
R967P
2D
AIThe SynGAP1 missense variant R967P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect for R967P, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.974374Disordered0.969686Binding0.3400.8880.750-2.506Likely Benign0.132Likely BenignLikely Benign0.175Likely Benign-0.76Neutral0.996Probably Damaging0.828Possibly Damaging4.14Benign0.17Tolerated0.21450.55330-22.9-59.07
c.2902G>A
G968S
2D
AIThe SynGAP1 missense variant G968S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.961360Binding0.3270.8960.750-4.484Likely Benign0.070Likely BenignLikely Benign0.124Likely Benign-0.35Neutral0.058Benign0.023Benign4.22Benign0.37Tolerated0.24820.569910-0.430.03
c.2902G>C
G968R
2D
AIThe SynGAP1 missense variant G968R is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the evidence strongly supports a benign classification, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.961360Binding0.3270.8960.750-4.492Likely Benign0.332Likely BenignLikely Benign0.140Likely Benign-0.63Neutral0.005Benign0.012Benign4.19Benign0.08Tolerated0.09720.5017-3-2-4.199.14
c.2902G>T
G968C
2D
AIThe SynGAP1 missense variant G968C is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.961360Binding0.3270.8960.750-8.441Likely Pathogenic0.117Likely BenignLikely Benign0.170Likely Benign-0.99Neutral0.992Probably Damaging0.820Possibly Damaging4.12Benign0.07Tolerated0.12940.4768-3-32.946.09
c.2903G>A
G968D
2D
AIThe SynGAP1 missense variant G968D is catalogued in gnomAD (ID 6‑33443455‑G‑A) but has no ClinVar entry. Across a broad panel of in‑silico predictors, every tool reports a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity, so the pathogenic‑prediction group is empty. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available for this variant. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.961360Binding0.3270.8960.7506-33443455-G-A16.20e-7-5.134Likely Benign0.179Likely BenignLikely Benign0.157Likely Benign-0.48Neutral0.440Benign0.198Benign4.19Benign0.21Tolerated4.3220.19650.3243-11-3.158.04
c.2903G>C
G968A
2D
AIThe SynGAP1 missense variant G968A is predicted to be benign by all available in‑silico tools. Consensus predictors (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized) and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all classify the change as benign. No tools predict pathogenicity, so the pathogenic group is empty. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized reports benign, and the SGM‑Consensus indicates “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Based on the unanimous benign predictions and the absence of ClinVar evidence, the variant is most likely benign and does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.961360Binding0.3270.8960.750-4.721Likely Benign0.070Likely BenignLikely Benign0.076Likely Benign-0.33Neutral0.245Benign0.140Benign4.24Benign0.68Tolerated0.34010.5154102.214.03
c.2903G>T
G968V
2D
AIThe SynGAP1 missense variant G968V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. The predictions do not contradict ClinVar status, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.961360Binding0.3270.8960.750-6.152Likely Benign0.093Likely BenignLikely Benign0.239Likely Benign-1.08Neutral0.918Possibly Damaging0.525Possibly Damaging4.19Benign0.11Tolerated0.12520.4036-1-34.642.08
c.2905G>A
G969R
2D
AIThe SynGAP1 missense variant G969R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.956572Binding0.4050.8980.750-4.783Likely Benign0.316Likely BenignLikely Benign0.152Likely Benign-0.70Neutral0.611Possibly Damaging0.305Benign4.20Benign0.01Affected0.10390.5473-3-2-4.199.14
c.2905G>C
G969R
2D
AIThe SynGAP1 missense variant G969R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.956572Binding0.4050.8980.750-4.783Likely Benign0.316Likely BenignLikely Benign0.152Likely Benign-0.70Neutral0.611Possibly Damaging0.305Benign4.20Benign0.01Affected0.10390.5473-3-2-4.199.14
c.2906G>A
G969E
2D
AIThe SynGAP1 missense variant G969E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.956572Binding0.4050.8980.750-4.721Likely Benign0.167Likely BenignLikely Benign0.118Likely Benign-0.10Neutral0.611Possibly Damaging0.171Benign4.28Benign0.01Affected0.16630.53990-2-3.172.06
c.2906G>C
G969A
2D
AIThe SynGAP1 missense variant G969A is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity, so the pathogenic‑prediction group is empty. High‑accuracy assessments corroborate this benign consensus: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are not available, so they do not influence the interpretation. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.956572Binding0.4050.8980.750-4.693Likely Benign0.076Likely BenignLikely Benign0.120Likely Benign-0.36Neutral0.393Benign0.096Benign4.25Benign0.51Tolerated0.34140.5096102.214.03
c.2906G>T
G969V
2D
AIThe SynGAP1 missense variant G969V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.956572Binding0.4050.8980.750-5.946Likely Benign0.089Likely BenignLikely Benign0.116Likely Benign-0.92Neutral0.761Possibly Damaging0.239Benign4.18Benign0.01Affected0.14970.3847-1-34.642.08
c.2908G>A
E970K
2D
AIThe SynGAP1 missense variant E970K is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign interpretation, and this conclusion does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.951925Disordered0.953422Binding0.3420.9020.750-3.344Likely Benign0.303Likely BenignLikely Benign0.102Likely Benign-0.24Neutral0.078Benign0.042Benign4.18Benign0.17Tolerated0.33720.736101-0.4-0.94
c.2908G>C
E970Q
2D
AIThe SynGAP1 missense variant E970Q is catalogued in gnomAD (6-33443460‑G‑C) and has no ClinVar entry. All available in silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool reports a pathogenic outcome. Grouping by consensus, the benign‑predicting tools comprise the entire set, while no pathogenic predictions are present. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are unavailable. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.951925Disordered0.953422Binding0.3420.9020.7506-33443460-G-C16.20e-7-2.662Likely Benign0.141Likely BenignLikely Benign0.053Likely Benign-0.23Neutral0.007Benign0.006Benign4.13Benign0.21Tolerated4.3220.25770.6899220.0-0.98
c.2909A>C
E970A
2D
AIThe SynGAP1 missense variant E970A is not reported in ClinVar and is absent from gnomAD. All available in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the consensus of all predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.951925Disordered0.953422Binding0.3420.9020.750-1.704Likely Benign0.156Likely BenignLikely Benign0.068Likely Benign-0.89Neutral0.069Benign0.018Benign4.15Benign0.19Tolerated0.36790.67980-15.3-58.04
c.2909A>T
E970V
2D
AIThe SynGAP1 missense variant E970V is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign interpretation, and this conclusion does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.951925Disordered0.953422Binding0.3420.9020.750-2.791Likely Benign0.208Likely BenignLikely Benign0.245Likely Benign-1.08Neutral0.002Benign0.002Benign4.11Benign0.08Tolerated0.19900.7037-2-27.7-29.98
c.290A>C
E97A
2D
AIThe SynGAP1 missense variant E97A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain. High‑accuracy assessments reinforce the benign prediction: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is also likely benign. Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for E97A, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.609018Binding0.3400.8670.625-3.091Likely Benign0.374AmbiguousLikely Benign0.098Likely Benign-0.58Neutral0.880Possibly Damaging0.636Possibly Damaging4.16Benign0.00Affected0.45050.77280-15.3-58.04
c.290A>G
E97G
2D
AIThe SynGAP1 missense variant E97G is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.609018Binding0.3400.8670.625-2.752Likely Benign0.282Likely BenignLikely Benign0.079Likely Benign-1.03Neutral0.947Possibly Damaging0.727Possibly Damaging4.07Benign0.00Affected0.32860.65690-23.1-72.06
c.290A>T
E97V
2D
AIThe SynGAP1 missense variant E97V is listed in gnomAD (ID 6‑33425898‑A‑T) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and Foldetta (FoldX‑MD/Rosetta stability assessment) has no available result. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta data is missing. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.609018Binding0.3400.8670.6256-33425898-A-T16.20e-7-3.743Likely Benign0.514AmbiguousLikely Benign0.124Likely Benign-1.17Neutral0.947Possibly Damaging0.788Possibly Damaging4.07Benign0.00Affected4.3210.10150.8155-2-27.7-29.98
c.2910G>C
E970D
2D
AIThe SynGAP1 missense variant E970D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification—there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.951925Disordered0.953422Binding0.3420.9020.750-3.381Likely Benign0.062Likely BenignLikely Benign0.063Likely Benign-0.44Neutral0.001Benign0.001Benign4.14Benign0.33Tolerated0.27290.4610320.0-14.03
c.2910G>T
E970D
2D
AIThe SynGAP1 missense variant E970D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.951925Disordered0.953422Binding0.3420.9020.750-3.381Likely Benign0.062Likely BenignLikely Benign0.063Likely Benign-0.44Neutral0.001Benign0.001Benign4.14Benign0.33Tolerated0.27290.4610320.0-14.03
c.2911C>A
P971T
2D
AIThe SynGAP1 missense variant P971T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.951523Binding0.5450.9050.625-5.627Likely Benign0.053Likely BenignLikely Benign0.053Likely Benign-0.95Neutral0.001Benign0.003Benign3.96Benign0.00Affected0.13880.58880-10.93.99
c.2911C>G
P971A
2D
AIThe SynGAP1 missense variant P971A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.951523Binding0.5450.9050.625-4.244Likely Benign0.049Likely BenignLikely Benign0.060Likely Benign-0.51Neutral0.000Benign0.002Benign4.05Benign0.00Affected0.31000.52821-13.4-26.04
c.2911C>T
P971S
2D
AIThe SynGAP1 missense variant P971S is catalogued in gnomAD (ID 6‑33443463‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) all indicate a benign or likely benign outcome. Only SIFT classifies the change as pathogenic, representing a minority opinion. High‑accuracy assessments further support benignity: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise reports likely benign. No Foldetta stability analysis is available, so it does not influence the overall assessment. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.951523Binding0.5450.9050.6256-33443463-C-T16.20e-7-4.188Likely Benign0.061Likely BenignLikely Benign0.058Likely Benign-0.51Neutral0.002Benign0.003Benign3.99Benign0.00Affected4.3220.30090.5667-110.8-10.04
c.2912C>G
P971R
2D
AIThe SynGAP1 missense variant P971R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.951523Binding0.5450.9050.625-4.407Likely Benign0.149Likely BenignLikely Benign0.042Likely Benign-1.01Neutral0.453Possibly Damaging0.078Benign3.91Benign0.00Affected0.13060.38180-2-2.959.07
c.2912C>T
P971L
2D
AIThe SynGAP1 missense variant P971L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.951523Binding0.5450.9050.625-4.892Likely Benign0.070Likely BenignLikely Benign0.030Likely Benign-1.57Neutral0.144Benign0.026Benign3.93Benign0.00Affected0.20460.5985-3-35.416.04
c.2914C>A
P972T
2D
AIThe SynGAP1 missense variant P972T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.891961Disordered0.954150Binding0.4720.9040.625-5.144Likely Benign0.057Likely BenignLikely Benign0.062Likely Benign-1.01Neutral0.078Benign0.042Benign4.29Benign0.03Affected0.18020.57260-10.93.99
c.2915C>A
P972H
2D
AIThe SynGAP1 missense variant P972H is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools (polyPhen‑2 HumDiv and SIFT) predict pathogenicity, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods points to a benign classification, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.891961Disordered0.954150Binding0.4720.9040.625-4.791Likely Benign0.087Likely BenignLikely Benign0.049Likely Benign-1.62Neutral0.589Possibly Damaging0.229Benign4.19Benign0.02Affected0.19300.47980-2-1.640.02
c.2915C>G
P972R
2D
AIThe SynGAP1 missense variant P972R is reported in gnomAD (ID 6‑33443467‑C‑G) but has no ClinVar entry. All evaluated in silico predictors classify it as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are unavailable. Based on the unanimous benign predictions and lack of ClinVar pathogenic annotation, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.891961Disordered0.954150Binding0.4720.9040.6256-33443467-C-G-4.483Likely Benign0.139Likely BenignLikely Benign0.043Likely Benign-1.44Neutral0.290Benign0.114Benign4.23Benign0.12Tolerated4.3220.13790.3931-20-2.959.07
c.2915C>T
P972L
2D
AIThe SynGAP1 missense variant P972L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.891961Disordered0.954150Binding0.4720.9040.625-4.399Likely Benign0.081Likely BenignLikely Benign0.020Likely Benign-1.73Neutral0.036Benign0.026Benign4.24Benign0.02Affected0.21070.5447-3-35.416.04
c.2917G>A
G973R
2D
AIThe SynGAP1 missense variant G973R is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.959498Binding0.3900.8970.625-3.950Likely Benign0.329Likely BenignLikely Benign0.072Likely Benign-0.37Neutral0.001Benign0.003Benign4.16Benign0.01Affected0.09300.4532-3-2-4.199.14
c.2917G>C
G973R
2D
AIThe SynGAP1 missense variant G973R is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic call comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta results are not available for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.959498Binding0.3900.8970.625-3.950Likely Benign0.329Likely BenignLikely Benign0.072Likely Benign-0.37Neutral0.001Benign0.003Benign4.16Benign0.01Affected0.09300.4532-3-2-4.199.14
c.2917G>T
G973W
2D
AIThe SynGAP1 missense variant G973W is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized reports Benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for G973W, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.959498Binding0.3900.8970.625-6.896Likely Benign0.329Likely BenignLikely Benign0.105Likely Benign-1.53Neutral0.983Probably Damaging0.813Possibly Damaging4.10Benign0.00Affected0.08460.4046-7-2-0.5129.16
c.2918G>A
G973E
2D
AIThe SynGAP1 missense variant G973E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the consensus of the majority of tools and the high‑accuracy predictions point to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.959498Binding0.3900.8970.625-3.712Likely Benign0.210Likely BenignLikely Benign0.079Likely Benign-0.72Neutral0.001Benign0.003Benign4.19Benign0.01Affected0.14630.42580-2-3.172.06
c.2918G>C
G973A
2D
AIThe SynGAP1 missense variant G973A is reported in gnomAD (ID 6‑33443470‑G‑C) but has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. The high‑accuracy consensus (SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly supports a benign classification, and this assessment is consistent with the absence of a ClinVar pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.959498Binding0.3900.8970.6256-33443470-G-C16.20e-7-3.847Likely Benign0.075Likely BenignLikely Benign0.091Likely Benign0.14Neutral0.112Benign0.028Benign4.30Benign0.62Tolerated4.3220.34050.5133012.214.03
c.2918G>T
G973V
2D
AIThe SynGAP1 missense variant G973V is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it as pathogenic. Grouping by consensus, the benign‑predicting tools outnumber the single pathogenic prediction. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus—derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields a benign classification. Foldetta results are unavailable, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.959498Binding0.3900.8970.625-4.688Likely Benign0.097Likely BenignLikely Benign0.092Likely Benign-0.76Neutral0.224Benign0.091Benign4.18Benign0.01Affected0.13920.3684-1-34.642.08
c.291G>C
E97D
2D
AIThe SynGAP1 missense variant E97D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the overall assessment. Overall, the majority of evidence points to the variant being most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.609018Binding0.3400.8670.625-3.239Likely Benign0.077Likely BenignLikely Benign0.081Likely Benign-0.49Neutral0.880Possibly Damaging0.636Possibly Damaging4.12Benign0.00Affected4.3210.19870.5559320.0-14.03
c.2920G>A
D974N
2D
AIThe SynGAP1 missense variant D974N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect. Consensus predictors such as SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) and high‑accuracy methods including AlphaMissense‑Optimized all classify the variant as benign. Additional in silico assessments—REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM—also predict a benign outcome. No tool in the dataset suggests pathogenicity. Protein‑stability analysis via Foldetta is unavailable for this variant. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.964377Binding0.3890.8970.625-4.051Likely Benign0.145Likely BenignLikely Benign0.088Likely Benign-0.35Neutral0.144Benign0.085Benign4.20Benign0.09Tolerated0.19720.7698210.0-0.98
c.2920G>C
D974H
2D
AIThe SynGAP1 missense variant D974H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.964377Binding0.3890.8970.625-3.034Likely Benign0.333Likely BenignLikely Benign0.109Likely Benign-0.95Neutral0.744Possibly Damaging0.382Benign4.14Benign0.02Affected0.22490.78031-10.322.05
c.2920G>T
D974Y
2D
AIThe SynGAP1 missense variant D974Y is not reported in ClinVar and has no entries in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the majority of computational evidence points to a benign impact, which is consistent with the absence of ClinVar pathogenic classification and gnomAD observations. Thus, the variant is most likely benign, and this assessment does not contradict any existing ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.964377Binding0.3890.8970.625-4.290Likely Benign0.384AmbiguousLikely Benign0.130Likely Benign-1.85Neutral0.716Possibly Damaging0.284Benign4.13Benign0.01Affected0.10720.6627-4-32.248.09
c.2921A>C
D974A
2D
AIThe SynGAP1 missense variant D974A is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) indicates likely benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the consensus of available predictions indicates that D974A is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.964377Binding0.3890.8970.625-2.619Likely Benign0.224Likely BenignLikely Benign0.242Likely Benign-0.96Neutral0.001Benign0.002Benign4.22Benign0.04Affected0.33980.71290-25.3-44.01
c.2921A>G
D974G
2D
AIThe SynGAP1 missense variant D974G is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is benign, and this conclusion does not contradict any ClinVar annotation (none present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.964377Binding0.3890.8970.625-1.638Likely Benign0.188Likely BenignLikely Benign0.203Likely Benign-0.72Neutral0.036Benign0.026Benign4.18Benign0.06Tolerated0.33790.67711-13.1-58.04
c.2921A>T
D974V
2D
AIThe SynGAP1 missense variant D974V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the collective predictions strongly suggest that D974V is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.964377Binding0.3890.8970.625-3.629Likely Benign0.351AmbiguousLikely Benign0.211Likely Benign-1.49Neutral0.001Benign0.002Benign4.16Benign0.01Affected0.14490.7286-2-37.7-15.96
c.2922C>A
D974E
2D
AIThe SynGAP1 missense variant D974E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. The variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.964377Binding0.3890.8970.625-3.617Likely Benign0.109Likely BenignLikely Benign0.078Likely Benign-0.63Neutral0.036Benign0.026Benign4.26Benign0.05Affected0.21190.7516320.014.03
c.2922C>G
D974E
2D
AIThe SynGAP1 missense variant D974E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. The variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.964377Binding0.3890.8970.625-3.617Likely Benign0.109Likely BenignLikely Benign0.078Likely Benign-0.63Neutral0.036Benign0.026Benign4.26Benign0.05Affected0.21190.7516320.014.03
c.2923A>C
T975P
2D
AIThe SynGAP1 missense variant T975P has no ClinVar entry and is not reported in gnomAD. All evaluated in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports a benign effect, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence strongly supports a benign classification, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.871313Disordered0.969331Binding0.3320.8900.625-2.181Likely Benign0.071Likely BenignLikely Benign0.286Likely Benign-1.21Neutral0.000Benign0.002Benign4.14Benign0.06Tolerated0.20470.47580-1-0.9-3.99
c.2923A>G
T975A
2D
AIThe SynGAP1 missense change T975A is not reported in ClinVar and is absent from gnomAD. All evaluated in‑silico predictors classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports a benign effect, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the computational evidence strongly supports a benign classification, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.871313Disordered0.969331Binding0.3320.8900.625-2.866Likely Benign0.063Likely BenignLikely Benign0.110Likely Benign-0.71Neutral0.000Benign0.002Benign4.19Benign0.18Tolerated0.38210.4275102.5-30.03
c.2923A>T
T975S
2D
AIThe SynGAP1 missense variant T975S is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, is not available for this variant. Overall, the predictions strongly suggest that T975S is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.871313Disordered0.969331Binding0.3320.8900.625-2.743Likely Benign0.068Likely BenignLikely Benign0.127Likely Benign-0.57Neutral0.059Benign0.061Benign4.16Benign0.20Tolerated0.32280.436611-0.1-14.03
c.2926T>A
F976I
2D
AIThe SynGAP1 missense variant F976I has no ClinVar entry and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.975061Binding0.3110.8940.625-4.595Likely Benign0.364AmbiguousLikely Benign0.148Likely Benign-1.16Neutral0.666Possibly Damaging0.265Benign4.16Benign0.21Tolerated0.27900.2714101.7-34.02
c.2926T>C
F976L
2D
AIThe SynGAP1 missense variant F976L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), which classifies the variant as “Likely Benign.” In contrast, AlphaMissense‑Default predicts a pathogenic effect, while AlphaMissense‑Optimized is uncertain. No Foldetta (FoldX‑MD/ Rosetta) stability result is available, so it does not contribute to the assessment. Overall, the majority of high‑confidence predictors indicate a benign impact, and this is consistent with the lack of ClinVar evidence. Thus, the variant is most likely benign, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.975061Binding0.3110.8940.625-2.432Likely Benign0.825Likely PathogenicAmbiguous0.237Likely Benign-0.87Neutral0.264Benign0.102Benign4.20Benign0.53Tolerated4.3220.28290.3082201.0-34.02
c.2926T>G
F976V
2D
AIThe SynGAP1 missense variant F976V is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign classification, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.975061Binding0.3110.8940.625-3.328Likely Benign0.268Likely BenignLikely Benign0.190Likely Benign-1.32Neutral0.451Benign0.157Benign4.18Benign0.23Tolerated0.26960.2902-1-11.4-48.04
c.2927T>A
F976Y
2D
AIThe SynGAP1 missense variant F976Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. The variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.975061Binding0.3110.8940.625-3.902Likely Benign0.225Likely BenignLikely Benign0.172Likely Benign-0.50Neutral0.925Possibly Damaging0.529Possibly Damaging4.11Benign0.80Tolerated0.19420.225773-4.116.00
c.2927T>C
F976S
2D
AIThe SynGAP1 missense variant F976S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.975061Binding0.3110.8940.625-2.393Likely Benign0.432AmbiguousLikely Benign0.217Likely Benign-0.73Neutral0.292Benign0.102Benign4.16Benign0.49Tolerated0.44320.1134-3-2-3.6-60.10
c.2927T>G
F976C
2D
AIThe SynGAP1 missense variant F976C is not reported in ClinVar and is absent from gnomAD. In silico predictors cluster into two groups: benign predictions come from REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, whereas pathogenic predictions arise from polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign and the SGM‑Consensus likewise indicates Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for F976C, and this conclusion is not in conflict with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.975061Binding0.3110.8940.625-5.490Likely Benign0.490AmbiguousLikely Benign0.103Likely Benign-1.10Neutral0.977Probably Damaging0.840Possibly Damaging4.09Benign0.10Tolerated0.29610.2505-4-2-0.3-44.04
c.2928T>A
F976L
2D
AIThe SynGAP1 missense variant F976L is not reported in ClinVar (ClinVar ID None) but is present in gnomAD (ID 6‑33443480‑T‑A). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. Only AlphaMissense‑Default predicts a pathogenic outcome, while AlphaMissense‑Optimized is uncertain. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from high‑accuracy predictors and consensus analysis indicates that F976L is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.975061Binding0.3110.8940.6256-33443480-T-A21.24e-6-2.432Likely Benign0.825Likely PathogenicAmbiguous0.212Likely Benign-0.87Neutral0.264Benign0.102Benign4.20Benign0.53Tolerated4.3220.28290.3082201.0-34.02
c.2929G>A
A977T
2D
AIThe SynGAP1 missense variant A977T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.975330Binding0.3060.8840.625-3.814Likely Benign0.118Likely BenignLikely Benign0.106Likely Benign-0.84Neutral0.965Probably Damaging0.782Possibly Damaging4.00Benign0.02Affected0.21550.618510-2.530.03
c.2929G>C
A977P
2D
AIThe SynGAP1 missense variant A977P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for A977P, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.975330Binding0.3060.8840.625-2.665Likely Benign0.135Likely BenignLikely Benign0.094Likely Benign-1.12Neutral0.990Probably Damaging0.892Possibly Damaging3.94Benign0.02Affected0.24050.52121-1-3.426.04
c.2929G>T
A977S
2D
AIThe SynGAP1 missense variant A977S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence indicates that A977S is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.975330Binding0.3060.8840.625-2.909Likely Benign0.089Likely BenignLikely Benign0.091Likely Benign-0.38Neutral0.965Probably Damaging0.702Possibly Damaging4.02Benign0.45Tolerated0.28200.537311-2.616.00
c.292C>A
H98N
2D
AIThe SynGAP1 missense variant H98N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.631713Binding0.3480.8720.625-3.855Likely Benign0.070Likely BenignLikely Benign0.103Likely Benign-0.35Neutral0.115Benign0.012Benign4.24Benign0.00Affected0.20030.375921-0.3-23.04
c.292C>G
H98D
2D
AIThe SynGAP1 missense variant H98D is reported in gnomAD (variant ID 6‑33425900‑C‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) all classify the change as benign. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is “Likely Benign.” No Foldetta stability result is available, so it does not influence the assessment. Overall, the consensus of the available predictions indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.631713Binding0.3480.8720.6256-33425900-C-G16.20e-7-1.739Likely Benign0.167Likely BenignLikely Benign0.140Likely Benign-0.42Neutral0.115Benign0.012Benign4.24Benign0.00Affected4.3210.27320.3018-11-0.3-22.05
c.292C>T
H98Y
2D
AIThe SynGAP1 missense variant H98Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.631713Binding0.3480.8720.625-4.050Likely Benign0.135Likely BenignLikely Benign0.112Likely Benign-0.86Neutral0.444Benign0.024Benign4.19Benign0.00Affected0.09500.5024021.926.03
c.2930C>A
A977D
2D
AIThe SynGAP1 missense variant A977D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy methods give a consistent benign signal: AlphaMissense‑Optimized predicts benign, SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates likely benign, while Foldetta’s protein‑folding stability assessment is unavailable. Overall, the majority of evidence points to a benign impact for A977D, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.975330Binding0.3060.8840.625-4.007Likely Benign0.717Likely PathogenicLikely Benign0.130Likely Benign-1.15Neutral0.990Probably Damaging0.892Possibly Damaging3.96Benign0.01Affected0.22530.26510-2-5.344.01
c.2930C>G
A977G
2D
AIThe SynGAP1 missense variant A977G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for A977G, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.975330Binding0.3060.8840.625-3.250Likely Benign0.138Likely BenignLikely Benign0.066Likely Benign-0.79Neutral0.965Probably Damaging0.702Possibly Damaging4.03Benign0.05Affected0.21800.440810-2.2-14.03
c.2930C>T
A977V
2D
AIThe SynGAP1 missense variant A977V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for A977V, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.975330Binding0.3060.8840.625-3.542Likely Benign0.151Likely BenignLikely Benign0.064Likely Benign-1.15Neutral0.818Possibly Damaging0.457Possibly Damaging4.01Benign0.01Affected0.19660.5727002.428.05
c.2932C>A
P978T
2D
AIThe SynGAP1 missense variant P978T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; the Foldetta stability analysis is not available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.819762Disordered0.975775Binding0.4250.8920.625-4.949Likely Benign0.217Likely BenignLikely Benign0.125Likely Benign-1.23Neutral0.818Possibly Damaging0.453Possibly Damaging4.21Benign0.04Affected0.18170.70890-10.93.99
c.2932C>G
P978A
2D
AIThe SynGAP1 missense variant P978A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; no tool predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.819762Disordered0.975775Binding0.4250.8920.625-3.994Likely Benign0.121Likely BenignLikely Benign0.062Likely Benign-1.39Neutral0.008Benign0.010Benign4.30Benign0.07Tolerated0.34170.58911-13.4-26.04
c.2933C>A
P978Q
2D
AIThe SynGAP1 missense variant P978Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; the Foldetta stability analysis is not available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.819762Disordered0.975775Binding0.4250.8920.625-4.741Likely Benign0.305Likely BenignLikely Benign0.091Likely Benign-1.72Neutral0.990Probably Damaging0.726Possibly Damaging4.15Benign0.01Affected0.16510.56990-1-1.931.01
c.2933C>G
P978R
2D
AIThe SynGAP1 missense variant P978R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, all of which classify the variant as benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as likely benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence from multiple independent predictors indicates that P978R is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.819762Disordered0.975775Binding0.4250.8920.625-2.852Likely Benign0.487AmbiguousLikely Benign0.105Likely Benign-2.10Neutral0.970Probably Damaging0.726Possibly Damaging4.15Benign0.01Affected0.15300.45900-2-2.959.07
c.2933C>T
P978L
2D
AIThe SynGAP1 missense variant P978L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.819762Disordered0.975775Binding0.4250.8920.625-4.621Likely Benign0.386AmbiguousLikely Benign0.092Likely Benign-2.08Neutral0.818Possibly Damaging0.378Benign4.15Benign0.01Affected0.23260.6997-3-35.416.04
c.2935T>A
F979I
2D
AIThe SynGAP1 missense variant F979I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy methods reinforce the benign prediction: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta data are missing. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.977500Binding0.2740.8890.625-4.053Likely Benign0.512AmbiguousLikely Benign0.163Likely Benign-1.07Neutral0.925Possibly Damaging0.629Possibly Damaging4.19Benign0.06Tolerated0.23680.3009101.7-34.02
c.2935T>G
F979V
2D
AIThe SynGAP1 missense variant F979V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for F979V, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.977500Binding0.2740.8890.625-3.325Likely Benign0.434AmbiguousLikely Benign0.199Likely Benign-1.03Neutral0.925Possibly Damaging0.629Possibly Damaging4.21Benign0.04Affected0.22600.3176-1-11.4-48.04
c.2936T>A
F979Y
2D
AIThe SynGAP1 missense variant F979Y is not reported in ClinVar and is absent from gnomAD. All available in‑silico predictors classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence strongly supports a benign impact, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.977500Binding0.2740.8890.625-3.420Likely Benign0.277Likely BenignLikely Benign0.123Likely Benign-0.26Neutral0.451Benign0.285Benign4.18Benign0.06Tolerated0.14510.284373-4.116.00
c.2936T>C
F979S
2D
AIThe SynGAP1 missense variant F979S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and the AlphaMissense‑Optimized score also indicates a benign outcome. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation because no ClinVar entry exists for F979S.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.977500Binding0.2740.8890.625-2.350Likely Benign0.718Likely PathogenicLikely Benign0.211Likely Benign-0.05Neutral0.451Benign0.220Benign4.23Benign0.01Affected0.43970.0384-3-2-3.6-60.10
c.2936T>G
F979C
2D
AIThe SynGAP1 missense variant F979C is not reported in ClinVar and has no gnomAD entry. Consensus from high‑accuracy predictors is benign: AlphaMissense‑Optimized scores it benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates likely benign. Other tools that agree with benign include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Pathogenic predictions come from polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, did not return a result for this variant, so its stability impact is unavailable. Overall, the majority of evidence points to a benign effect, and this is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.977500Binding0.2740.8890.625-6.395Likely Benign0.589Likely PathogenicLikely Benign0.160Likely Benign-0.94Neutral0.994Probably Damaging0.888Possibly Damaging4.15Benign0.00Affected0.26460.2179-4-2-0.3-44.04
c.2937C>A
F979L
2D
AIThe SynGAP1 missense variant F979L has no ClinVar record and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM, while polyPhen‑2 HumDiv and AlphaMissense‑Default predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, and the SGM‑Consensus remains Likely Benign; Foldetta results are unavailable. Overall, the balance of evidence favors a benign interpretation, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.977500Binding0.2740.8890.625-2.341Likely Benign0.870Likely PathogenicAmbiguous0.328Likely Benign-1.00Neutral0.625Possibly Damaging0.430Benign4.22Benign0.73Tolerated4.3220.24470.3876201.0-34.02
c.2937C>G
F979L
2D
AIThe SynGAP1 missense variant F979L has no ClinVar record and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM, while polyPhen‑2 HumDiv and AlphaMissense‑Default predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, and the SGM‑Consensus remains Likely Benign; Foldetta results are unavailable. Overall, the balance of evidence favors a benign interpretation, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.977500Binding0.2740.8890.625-2.341Likely Benign0.870Likely PathogenicAmbiguous0.328Likely Benign-1.00Neutral0.625Possibly Damaging0.430Benign4.22Benign0.73Tolerated4.3220.24470.3876201.0-34.02
c.2938C>A
H980N
2D
AIThe SynGAP1 missense variant H980N is not reported in ClinVar or gnomAD. Functional prediction tools largely agree on a benign effect. Benign calls come from REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized, while only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign classification. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus confirms a benign result; Foldetta data are unavailable, so no additional stability evidence is considered. Overall, the computational evidence indicates that H980N is most likely benign, and this conclusion does not conflict with the absence of a ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.974598Binding0.3090.8920.625-4.728Likely Benign0.291Likely BenignLikely Benign0.070Likely Benign-1.07Neutral0.451Benign0.209Benign4.17Benign0.00Affected0.23460.363821-0.3-23.04
c.2938C>G
H980D
2D
AIThe SynGAP1 missense variant H980D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. The Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of computational evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.974598Binding0.3090.8920.625-5.489Likely Benign0.729Likely PathogenicLikely Benign0.117Likely Benign-1.38Neutral0.451Benign0.265Benign4.18Benign0.00Affected0.26080.30661-1-0.3-22.05
c.2938C>T
H980Y
2D
AIThe SynGAP1 missense variant H980Y is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for H980Y, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.974598Binding0.3090.8920.625-4.104Likely Benign0.299Likely BenignLikely Benign0.083Likely Benign-1.12Neutral0.925Possibly Damaging0.529Possibly Damaging4.13Benign0.00Affected0.15240.4706021.926.03
c.2939A>C
H980P
2D
AIThe SynGAP1 missense variant H980P is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools largely favor a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates a likely benign outcome. In contrast, two tools—polyPhen‑2 HumDiv and SIFT—classify the change as pathogenic. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign and the SGM‑Consensus (majority vote) is likely benign; no Foldetta stability data are available. Overall, the preponderance of evidence points to a benign effect for H980P, and this conclusion is not in conflict with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.974598Binding0.3090.8920.625-3.071Likely Benign0.151Likely BenignLikely Benign0.136Likely Benign-1.70Neutral0.802Possibly Damaging0.432Benign4.15Benign0.00Affected0.22740.43010-21.6-40.02
c.2939A>G
H980R
2D
AIThe SynGAP1 missense variant H980R is listed in gnomAD (ID 6‑33443491‑A‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.974598Binding0.3090.8920.6256-33443491-A-G16.20e-7-2.736Likely Benign0.409AmbiguousLikely Benign0.095Likely Benign-1.44Neutral0.802Possibly Damaging0.354Benign4.17Benign0.00Affected4.3210.24390.381002-1.319.05
c.2939A>T
H980L
2D
AIThe SynGAP1 missense variant H980L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. The variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.974598Binding0.3090.8920.625-1.984Likely Benign0.293Likely BenignLikely Benign0.187Likely Benign-1.98Neutral0.625Possibly Damaging0.265Benign4.16Benign0.00Affected0.14880.5538-2-37.0-23.98
c.293A>C
H98P
2D
AIThe SynGAP1 missense variant H98P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. There is no ClinVar classification to contradict this conclusion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.631713Binding0.3480.8720.625-1.460Likely Benign0.069Likely BenignLikely Benign0.275Likely Benign-0.83Neutral0.659Possibly Damaging0.024Benign4.20Benign0.00Affected0.20620.46690-21.6-40.02
c.293A>G
H98R
2D
AIThe SynGAP1 missense variant H98R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.631713Binding0.3480.8720.625-2.772Likely Benign0.180Likely BenignLikely Benign0.116Likely Benign-0.39Neutral0.115Benign0.006Benign4.27Benign0.00Affected0.22710.302220-1.319.05
c.293A>T
H98L
2D
AIThe SynGAP1 H98L missense variant is reported in gnomAD (ID 6‑33425901‑A‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts benign, SGM‑Consensus is likely benign, and Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for H98L, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.631713Binding0.3480.8720.6256-33425901-A-T16.32e-7-1.804Likely Benign0.113Likely BenignLikely Benign0.194Likely Benign-0.51Neutral0.115Benign0.012Benign4.24Benign0.00Affected4.3210.11250.6291-3-27.0-23.98
c.2940T>A
H980Q
2D
AIThe SynGAP1 missense variant H980Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for H980Q, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.974598Binding0.3090.8920.625-4.014Likely Benign0.385AmbiguousLikely Benign0.090Likely Benign-1.35Neutral0.802Possibly Damaging0.432Benign4.18Benign0.00Affected0.22360.393630-0.3-9.01
c.2940T>G
H980Q
2D
AIThe SynGAP1 missense variant H980Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for H980Q, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.974598Binding0.3090.8920.625-4.014Likely Benign0.385AmbiguousLikely Benign0.090Likely Benign-1.35Neutral0.802Possibly Damaging0.432Benign4.18Benign0.00Affected0.22360.393630-0.3-9.01
c.2941G>A
G981S
2D
AIThe SynGAP1 missense variant G981S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; the Foldetta stability analysis is not available for this variant. Overall, the majority of evidence—including the consensus and high‑accuracy tools—points to a benign effect. This conclusion is not contradicted by ClinVar, which contains no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.798249Disordered0.970320Binding0.2750.8970.625-2.749Likely Benign0.274Likely BenignLikely Benign0.130Likely Benign-0.57Neutral0.979Probably Damaging0.907Possibly Damaging3.87Benign0.00Affected0.25660.547010-0.430.03
c.2941G>C
G981R
2D
AIThe SynGAP1 missense variant G981R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, SGM‑Consensus as Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) is not available for this variant. Overall, the majority of evidence points toward a benign impact, and this conclusion does not contradict any ClinVar annotation because none exists. Thus, the variant is most likely benign based on current predictive tools.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.798249Disordered0.970320Binding0.2750.8970.625-1.264Likely Benign0.953Likely PathogenicAmbiguous0.207Likely Benign-2.11Neutral0.999Probably Damaging0.985Probably Damaging3.74Benign0.00Affected0.09900.4776-3-2-4.199.14
c.2941G>T
G981C
2D
AIThe SynGAP1 missense variant G981C is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact for G981C, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.798249Disordered0.970320Binding0.2750.8970.625-5.646Likely Benign0.593Likely PathogenicLikely Benign0.228Likely Benign-1.81Neutral1.000Probably Damaging0.992Probably Damaging3.72Benign0.00Affected0.13980.4593-3-32.946.09
c.2942G>A
G981D
2D
AIThe SynGAP1 missense variant G981D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, SGM‑Consensus as Likely Benign, and Foldetta results are unavailable. Taken together, the balance of evidence leans toward a benign interpretation; there is no ClinVar entry to contradict this assessment. Thus, the variant is most likely benign based on current computational predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.798249Disordered0.970320Binding0.2750.8970.625-5.280Likely Benign0.945Likely PathogenicAmbiguous0.159Likely Benign-1.64Neutral1.000Probably Damaging0.985Probably Damaging3.75Benign0.00Affected0.19610.28681-1-3.158.04
c.2942G>C
G981A
2D
AIThe SynGAP1 missense variant G981A is not reported in ClinVar and has no entry in gnomAD, indicating it is not catalogued in these databases. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.798249Disordered0.970320Binding0.2750.8970.625-3.374Likely Benign0.368AmbiguousLikely Benign0.064Likely Benign-0.95Neutral0.561Possibly Damaging0.376Benign3.95Benign0.00Affected0.35120.4925102.214.03
c.2942G>T
G981V
2D
AIThe SynGAP1 missense variant G981V is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign impact for G981V, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.798249Disordered0.970320Binding0.2750.8970.625-3.873Likely Benign0.714Likely PathogenicLikely Benign0.156Likely Benign-2.10Neutral0.997Probably Damaging0.958Probably Damaging3.75Benign0.00Affected0.13220.3861-1-34.642.08
c.2944T>A
Y982N
2D
AIThe SynGAP1 Y982N variant has no ClinVar record and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic impact are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments are mixed: AlphaMissense‑Optimized is uncertain, SGM‑Consensus is benign, and Foldetta results are unavailable. Overall, the majority of consensus‑based and high‑accuracy tools lean toward a benign interpretation. Thus, the variant is most likely benign, and this assessment does not contradict ClinVar status, which currently has no entry for Y982N.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.966717Binding0.2720.8950.625-4.536Likely Benign0.881Likely PathogenicAmbiguous0.175Likely Benign-1.14Neutral0.990Probably Damaging0.900Possibly Damaging3.88Benign0.00Affected0.20900.0545-2-2-2.2-49.07
c.2944T>C
Y982H
2D
AIThe SynGAP1 missense variant Y982H has no ClinVar record and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, and the SGM‑Consensus result is benign; Foldetta predictions are unavailable. Overall, the evidence is mixed, but the majority of consensus‑based and high‑accuracy tools lean toward a benign interpretation. Thus, the variant is most likely benign, and this assessment does not contradict any ClinVar status, as none is currently assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.966717Binding0.2720.8950.625-2.675Likely Benign0.893Likely PathogenicAmbiguous0.093Likely Benign-0.63Neutral0.990Probably Damaging0.900Possibly Damaging3.92Benign0.00Affected0.23520.054502-1.9-26.03
c.2944T>G
Y982D
2D
AIThe SynGAP1 missense variant Y982D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), which collectively suggest a likely benign outcome. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. The high‑accuracy AlphaMissense‑Optimized score is uncertain, and Foldetta (combining FoldX‑MD and Rosetta) has no available result for this variant. Overall, the balance of evidence leans toward a benign interpretation, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.966717Binding0.2720.8950.625-5.021Likely Benign0.952Likely PathogenicAmbiguous0.194Likely Benign-1.29Neutral0.990Probably Damaging0.856Possibly Damaging3.87Benign0.00Affected0.39590.0545-4-3-2.2-48.09
c.2945A>C
Y982S
2D
AIThe SynGAP1 missense variant Y982S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), which collectively suggest a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default predict a pathogenic impact. High‑accuracy assessments show the SGM‑Consensus as Likely Benign, AlphaMissense‑Optimized as Uncertain, and Foldetta results are unavailable. Overall, the balance of evidence leans toward a benign interpretation, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.966717Binding0.2720.8950.625-2.919Likely Benign0.841Likely PathogenicAmbiguous0.131Likely Benign-1.04Neutral0.965Probably Damaging0.783Possibly Damaging3.89Benign0.00Affected0.45560.1883-3-20.5-76.10
c.2945A>T
Y982F
2D
AIThe SynGAP1 missense variant Y982F is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.966717Binding0.2720.8950.625-3.431Likely Benign0.208Likely BenignLikely Benign0.154Likely Benign-0.36Neutral0.006Benign0.009Benign4.63Benign0.00Affected0.23510.2980734.1-16.00
c.2947A>C
S983R
2D
AIThe SynGAP1 missense variant S983R is reported in ClinVar as “Not submitted” and is not present in gnomAD. Prediction tools that agree on a benign effect include REVEL and ESM1b, whereas the majority of tools predict a pathogenic impact: PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. The high‑accuracy consensus, SGM‑Consensus, is derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN and also indicates a likely pathogenic outcome. AlphaMissense‑Optimized independently predicts pathogenicity. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from multiple in silico predictors points to a pathogenic effect for S983R, and this conclusion does not contradict any ClinVar annotation, as none is currently assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.707965Disordered0.960212Binding0.2770.8890.625-4.733Likely Benign0.992Likely PathogenicLikely Pathogenic0.156Likely Benign-2.66Deleterious0.997Probably Damaging0.995Probably Damaging2.03Pathogenic0.00Affected0.11630.37400-1-3.769.11
c.2947A>G
S983G
2D
AIThe SynGAP1 missense variant S983G is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (2 vs 2). High‑accuracy methods show AlphaMissense‑Optimized as benign; the SGM Consensus is unavailable, and Foldetta results are not provided, so no folding‑stability evidence is available. Overall, the balance of evidence (five pathogenic vs four benign predictions) suggests the variant is most likely pathogenic, and this assessment does not contradict any ClinVar status because the variant has not yet been classified in that database.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.707965Disordered0.960212Binding0.2770.8890.625-5.206Likely Benign0.638Likely PathogenicLikely Benign0.109Likely Benign-2.22Neutral0.979Probably Damaging0.982Probably Damaging2.17Pathogenic0.00Affected0.25210.4480100.4-30.03
c.2947A>T
S983C
2D
AIThe SynGAP1 missense variant S983C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools cluster into two groups: benign predictions come from REVEL and AlphaMissense‑Optimized, while pathogenic predictions are made by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, whereas the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely pathogenic effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points toward a pathogenic impact. This conclusion is not contradicted by ClinVar status, as no ClinVar classification exists for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.707965Disordered0.960212Binding0.2770.8890.625-7.083In-Between0.741Likely PathogenicLikely Benign0.162Likely Benign-2.64Deleterious0.999Probably Damaging0.997Probably Damaging2.02Pathogenic0.00Affected0.16570.52980-13.316.06
c.2948G>C
S983T
2D
AIThe SynGAP1 missense variant S983T is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (2 pathogenic vs. 2 benign). High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus and Foldetta (which would combine FoldX‑MD and Rosetta outputs) are unavailable. Overall, the balance of evidence leans toward pathogenicity, with five tools supporting a deleterious effect versus four supporting benign. This prediction does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.707965Disordered0.960212Binding0.2770.8890.625-4.493Likely Benign0.588Likely PathogenicLikely Benign0.172Likely Benign-1.65Neutral0.979Probably Damaging0.982Probably Damaging2.08Pathogenic0.00Affected0.20420.5517110.114.03
c.2948G>T
S983I
2D
AIThe SynGAP1 missense variant S983I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). In silico predictors that agree on a benign effect are REVEL and ESM1b, whereas the majority of tools predict a pathogenic outcome: PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). High‑accuracy assessments further support pathogenicity: AlphaMissense‑Optimized is pathogenic, and the SGM‑Consensus (3 pathogenic vs. 1 benign) is likely pathogenic. Foldetta results are unavailable. Overall, the preponderance of evidence indicates that S983I is most likely pathogenic, and this conclusion is not contradicted by the current ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.707965Disordered0.960212Binding0.2770.8890.625-6.259Likely Benign0.968Likely PathogenicLikely Pathogenic0.190Likely Benign-2.67Deleterious0.997Probably Damaging0.996Probably Damaging2.02Pathogenic0.00Affected0.13800.4625-1-25.326.08
c.2949C>A
S983R
2D
AIThe SynGAP1 missense variant S983R is reported in ClinVar as “Not submitted” and is not present in gnomAD. Prediction tools that agree on a benign effect include REVEL and ESM1b, whereas the majority of tools predict a pathogenic impact: PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). High‑accuracy assessments further support pathogenicity: AlphaMissense‑Optimized is pathogenic, and the SGM‑Consensus (3 pathogenic vs. 1 benign) is likely pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from both general and high‑accuracy predictors indicates that S983R is most likely pathogenic, and this conclusion does not contradict the ClinVar status, which currently lacks a classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.707965Disordered0.960212Binding0.2770.8890.625-4.733Likely Benign0.992Likely PathogenicLikely Pathogenic0.190Likely Benign-2.66Deleterious0.997Probably Damaging0.995Probably Damaging2.03Pathogenic0.00Affected0.11630.37400-1-3.769.11
c.2949C>G
S983R
2D
AIThe SynGAP1 missense variant S983R is reported in ClinVar as “Not submitted” and is not present in gnomAD. Prediction tools that agree on a benign effect include REVEL and ESM1b, whereas the majority of tools predict a pathogenic impact: PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). High‑accuracy assessments further support pathogenicity: AlphaMissense‑Optimized is pathogenic, and the SGM‑Consensus (3 pathogenic vs. 1 benign) is likely pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that S983R is most likely pathogenic, and this conclusion does not contradict the ClinVar status, which currently lacks a pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.707965Disordered0.960212Binding0.2770.8890.625-4.733Likely Benign0.992Likely PathogenicLikely Pathogenic0.190Likely Benign-2.66Deleterious0.997Probably Damaging0.995Probably Damaging2.03Pathogenic0.00Affected0.11630.37400-1-3.769.11
c.294T>A
H98Q
2D
AIThe SynGAP1 missense variant H98Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.631713Binding0.3480.8720.625-2.749Likely Benign0.104Likely BenignLikely Benign0.088Likely Benign-0.47Neutral0.002Benign0.000Benign4.26Benign0.00Affected0.18310.434730-0.3-9.01
c.294T>G
H98Q
2D
AIThe SynGAP1 missense variant H98Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.631713Binding0.3480.8720.625-2.749Likely Benign0.104Likely BenignLikely Benign0.088Likely Benign-0.47Neutral0.002Benign0.000Benign4.26Benign0.00Affected0.18310.434730-0.3-9.01
c.2950A>C
K984Q
2D
AIThe SynGAP1 missense variant K984Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.951648Binding0.2880.8950.750-2.932Likely Benign0.612Likely PathogenicLikely Benign0.083Likely Benign-0.67Neutral0.905Possibly Damaging0.637Possibly Damaging2.66Benign0.00Affected0.50540.1240Weaken110.4-0.04
c.2950A>G
K984E
2D
AIThe SynGAP1 missense variant K984E has no ClinVar record and is not reported in gnomAD. Prediction tools that classify the variant as benign include REVEL, PROVEAN, ESM1b, and FATHMM, while polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default predict it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” AlphaMissense‑Optimized is uncertain, and no Foldetta stability assessment is available. Overall, the majority of individual predictors lean toward benign, and the consensus score explicitly labels it benign, whereas a comparable number of tools predict pathogenicity. Based on the available evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.951648Binding0.2880.8950.750-4.909Likely Benign0.932Likely PathogenicAmbiguous0.086Likely Benign-0.88Neutral0.798Possibly Damaging0.535Possibly Damaging2.71Benign0.00Affected0.43530.1200010.40.94
c.2951A>C
K984T
2D
AIThe SynGAP1 missense variant K984T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, SGM‑Consensus as Likely Benign, and Foldetta results are unavailable. Overall, the predictions are mixed; however, the SGM‑Consensus and the majority of benign‑predicting tools lean toward a benign interpretation. This assessment does not contradict ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.951648Binding0.2880.8950.750-3.429Likely Benign0.854Likely PathogenicAmbiguous0.087Likely Benign-1.10Neutral0.951Possibly Damaging0.708Possibly Damaging2.71Benign0.00Affected0.24410.34630-13.2-27.07
c.2951A>G
K984R
2D
AIThe SynGAP1 missense variant K984R is reported in gnomAD (ID 6‑33443503‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the consensus of the majority of tools indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.951648Binding0.2880.8950.7506-33443503-A-G21.24e-6-2.044Likely Benign0.104Likely BenignLikely Benign0.082Likely Benign-0.41Neutral0.012Benign0.012Benign2.67Benign0.00Affected4.3210.50980.1558Weaken23-0.628.01
c.2951A>T
K984M
2D
AIThe SynGAP1 missense variant K984M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as “Uncertain” and the SGM‑Consensus as “Likely Benign”; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.951648Binding0.2880.8950.750-4.761Likely Benign0.934Likely PathogenicAmbiguous0.141Likely Benign-1.82Neutral0.995Probably Damaging0.944Probably Damaging2.60Benign0.00Affected0.15760.41680-15.83.02
c.2952G>C
K984N
2D
AIThe SynGAP1 missense variant K984N is catalogued in gnomAD (6‑33443504‑G‑C) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, and FATHMM, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. High‑accuracy assessments are mixed: AlphaMissense‑Optimized rates the variant as uncertain, SGM‑Consensus (a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) labels it “Likely Benign,” and Foldetta (which integrates FoldX‑MD and Rosetta outputs) has no available result for this residue. Overall, the balance of evidence leans toward a benign effect, with no pathogenic ClinVar classification to contradict this inference.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.951648Binding0.2880.8950.7506-33443504-G-C16.20e-7-3.020Likely Benign0.955Likely PathogenicAmbiguous0.091Likely Benign0.52Neutral0.951Possibly Damaging0.637Possibly Damaging2.89Benign0.00Affected4.3210.41380.1677010.4-14.07
c.2952G>T
K984N
2D
AISynGAP1 missense variant K984N has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict pathogenicity are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments are mixed: AlphaMissense‑Optimized is Uncertain, SGM‑Consensus is Likely Benign, and Foldetta results are unavailable. Overall, the balance of evidence leans toward a benign interpretation, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.951648Binding0.2880.8950.750-3.020Likely Benign0.955Likely PathogenicAmbiguous0.091Likely Benign0.52Neutral0.951Possibly Damaging0.637Possibly Damaging2.89Benign0.00Affected4.3210.41380.1677010.4-14.07
c.2953A>C
S985R
2D
AIThe SynGAP1 missense variant S985R has no ClinVar entry and is not reported in gnomAD. Prediction tools that classify it as benign include REVEL, PROVEAN, ESM1b, FATHMM, and the SGM‑Consensus (Likely Benign). Those that predict pathogenicity are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic, while the SGM‑Consensus remains benign; Foldetta, a protein‑folding stability method, has no available result for this variant. Consequently, the evidence is split evenly between benign and pathogenic predictions, with no contradiction to ClinVar status. The variant’s impact remains uncertain, and no definitive benign or pathogenic classification can be assigned based solely on current computational predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.720929Disordered0.941547Binding0.3020.8960.750-6.148Likely Benign0.991Likely PathogenicLikely Pathogenic0.174Likely Benign-2.40Neutral0.997Probably Damaging0.995Probably Damaging2.52Benign0.00Affected0.12130.39050-1-3.769.11
c.2953A>G
S985G
2D
AIThe SynGAP1 missense variant S985G is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster into two groups: benign (REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized) and pathogenic (polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT). The AlphaMissense‑Default score is uncertain, and Foldetta stability analysis is not available. High‑accuracy assessments show AlphaMissense‑Optimized predicting a benign effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates a likely benign outcome. Foldetta, which integrates FoldX‑MD and Rosetta outputs, has no reported result for this variant. Overall, the majority of reliable predictors and the SGM‑Consensus support a benign classification. The variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.720929Disordered0.941547Binding0.3020.8960.750-6.151Likely Benign0.546AmbiguousLikely Benign0.132Likely Benign-2.29Neutral0.979Probably Damaging0.982Probably Damaging2.51Benign0.00Affected0.26840.4540100.4-30.03
c.2953A>T
S985C
2D
AIThe SynGAP1 missense variant S985C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL and PROVEAN, whereas the majority of tools predict a pathogenic impact: polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Default all classify the variant as pathogenic. High‑accuracy assessments further support a deleterious outcome: AlphaMissense‑Optimized is uncertain, but the SGM‑Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is classified as Likely Pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from multiple in silico predictors indicates that S985C is most likely pathogenic, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.720929Disordered0.941547Binding0.3020.8960.750-8.918Likely Pathogenic0.860Likely PathogenicAmbiguous0.147Likely Benign-2.49Neutral0.999Probably Damaging0.997Probably Damaging2.48Pathogenic0.00Affected0.15310.53950-13.316.06
c.2954G>C
S985T
2D
AIThe SynGAP1 missense variant S985T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for S985T, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.720929Disordered0.941547Binding0.3020.8960.750-5.658Likely Benign0.475AmbiguousLikely Benign0.153Likely Benign-1.62Neutral0.979Probably Damaging0.982Probably Damaging2.54Benign0.00Affected0.18890.5844110.114.03
c.2954G>T
S985I
2D
AIThe SynGAP1 missense variant S985I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect are REVEL and FATHMM, whereas the remaining tools—PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized—consistently predict a pathogenic impact. ESM1b remains uncertain. High‑accuracy assessments further support pathogenicity: AlphaMissense‑Optimized is pathogenic, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a pathogenic verdict (2 pathogenic vs. 1 benign). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence indicates that S985I is most likely pathogenic, and this conclusion does not contradict any ClinVar annotation because no ClinVar status exists for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.720929Disordered0.941547Binding0.3020.8960.750-7.858In-Between0.971Likely PathogenicLikely Pathogenic0.131Likely Benign-2.78Deleterious0.997Probably Damaging0.996Probably Damaging2.50Benign0.00Affected0.13670.5206-1-25.326.08
c.2955T>A
S985R
2D
AIThe SynGAP1 missense variant S985R has no ClinVar entry and is not reported in gnomAD. Consensus predictions from multiple in‑silico tools are split: benign calls come from REVEL, PROVEAN, ESM1b, FATHMM, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) which reports a likely benign outcome. Pathogenic calls arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments are mixed: AlphaMissense‑Optimized predicts pathogenic, whereas the SGM‑Consensus (a majority‑vote aggregator) predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the predictions are evenly divided, leaving the variant’s clinical significance uncertain; it does not contradict any ClinVar status because none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.720929Disordered0.941547Binding0.3020.8960.750-6.148Likely Benign0.991Likely PathogenicLikely Pathogenic0.203Likely Benign-2.40Neutral0.997Probably Damaging0.995Probably Damaging2.52Benign0.00Affected0.12130.39050-1-3.769.11
c.2955T>G
S985R
2D
AISynGAP1 missense variant S985R has no ClinVar record and is not present in gnomAD. Computational predictions are mixed: benign calls come from REVEL, PROVEAN, ESM1b, FATHMM, and the SGM‑Consensus (Likely Benign). Pathogenic calls come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy tools give a split result: AlphaMissense‑Optimized predicts pathogenic, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts likely benign; Foldetta data are unavailable. Consequently, the variant’s predicted impact is ambiguous, with an equal number of benign and pathogenic scores. No ClinVar evidence contradicts these predictions. Thus, the variant is best classified as of uncertain significance, with no clear bias toward benign or pathogenic status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.720929Disordered0.941547Binding0.3020.8960.750-6.148Likely Benign0.991Likely PathogenicLikely Pathogenic0.203Likely Benign-2.40Neutral0.997Probably Damaging0.995Probably Damaging2.52Benign0.00Affected0.12130.39050-1-3.769.11
c.2956G>A
E986K
2D
AIThe SynGAP1 missense variant E986K is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect are REVEL and PROVEAN, while those that agree on a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. The remaining tools, ESM1b and AlphaMissense‑Optimized, return uncertain results and are not considered evidence for either side. The SGM Consensus, which takes a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a pathogenic verdict (2 pathogenic vs. 1 benign, with one uncertain). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of high‑accuracy predictors classify the variant as pathogenic, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.750527Disordered0.929726Binding0.3490.9020.750-7.174In-Between0.950Likely PathogenicAmbiguous0.164Likely Benign-2.19Neutral0.924Possibly Damaging0.722Possibly Damaging2.15Pathogenic0.00Affected0.27600.797301-0.4-0.94
c.2956G>C
E986Q
2D
AIThe SynGAP1 missense variant E986Q is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, and ESM1b, whereas those that agree on a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. The high‑accuracy AlphaMissense‑Optimized tool returns an uncertain result, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 pathogenic vs. 2 benign). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of available predictions (five pathogenic vs. three benign) lean toward a pathogenic interpretation. This assessment does not contradict ClinVar status, as the variant is not yet catalogued there. Thus, based on current computational evidence, the variant is most likely pathogenic.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.750527Disordered0.929726Binding0.3490.9020.750-4.471Likely Benign0.839Likely PathogenicAmbiguous0.160Likely Benign-1.66Neutral0.974Probably Damaging0.842Possibly Damaging2.14Pathogenic0.00Affected0.17000.7589220.0-0.98
c.2957A>C
E986A
2D
AIThe SynGAP1 missense variant E986A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, and ESM1b, whereas tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, FATHMM, and AlphaMissense‑Default. The high‑accuracy AlphaMissense‑Optimized score is uncertain, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a 2‑to‑2 split; Foldetta stability analysis is unavailable. Overall, the evidence is evenly divided, with no clear majority. Based on the current predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.750527Disordered0.929726Binding0.3490.9020.750-4.653Likely Benign0.895Likely PathogenicAmbiguous0.160Likely Benign-2.32Neutral0.552Possibly Damaging0.388Benign2.14Pathogenic0.00Affected0.42070.77330-15.3-58.04
c.2957A>G
E986G
2D
AIThe SynGAP1 missense variant E986G is not reported in ClinVar and has no entries in gnomAD. Prediction tools that agree on a benign effect include REVEL and ESM1b, whereas seven tools (PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and the SGM‑Consensus) predict a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, while the SGM‑Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—classifies the variant as likely pathogenic. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a pathogenic effect, and this assessment does not conflict with the ClinVar status, which currently contains no classification for E986G.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.750527Disordered0.929726Binding0.3490.9020.750-5.584Likely Benign0.834Likely PathogenicAmbiguous0.219Likely Benign-3.14Deleterious0.924Possibly Damaging0.784Possibly Damaging2.13Pathogenic0.00Affected0.28660.62250-23.1-72.06
c.2957A>T
E986V
2D
AIThe SynGAP1 E986V missense variant is not reported in ClinVar and has no gnomAD entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b, whereas pathogenic predictions arise from PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments reinforce the pathogenic signal: AlphaMissense‑Optimized predicts pathogenic, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default (pathogenic), ESM1b (benign), FATHMM (pathogenic), and PROVEAN (pathogenic)—also indicates pathogenic. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods points to a pathogenic effect for E986V, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.750527Disordered0.929726Binding0.3490.9020.750-4.511Likely Benign0.965Likely PathogenicLikely Pathogenic0.220Likely Benign-3.48Deleterious0.018Benign0.028Benign2.10Pathogenic0.00Affected0.11460.7960-2-27.7-29.98
c.2958G>C
E986D
2D
AIThe SynGAP1 missense variant E986D is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (two pathogenic vs two benign votes) and Foldetta results are unavailable. Overall, the majority of conventional tools lean toward pathogenicity, but the single high‑accuracy benign prediction and the inconclusive consensus leave the variant’s impact uncertain. There is no contradiction with ClinVar status, as the variant has not been reported there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.750527Disordered0.929726Binding0.3490.9020.750-4.001Likely Benign0.628Likely PathogenicLikely Benign0.129Likely Benign-1.22Neutral0.974Probably Damaging0.715Possibly Damaging2.32Pathogenic0.00Affected0.20810.5364320.0-14.03
c.2958G>T
E986D
2D
AIThe SynGAP1 missense variant E986D is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (two pathogenic vs two benign votes) and Foldetta results are unavailable. Overall, the majority of conventional tools lean toward pathogenicity, but the single high‑accuracy benign prediction and the inconclusive consensus leave the variant’s impact uncertain. There is no contradiction with ClinVar status, as the variant has not been reported there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.750527Disordered0.929726Binding0.3490.9020.750-4.001Likely Benign0.628Likely PathogenicLikely Benign0.129Likely Benign-1.22Neutral0.974Probably Damaging0.715Possibly Damaging2.32Pathogenic0.00Affected0.20810.5364320.0-14.03
c.2959G>A
D987N
2D
AIThe SynGAP1 D987N missense variant is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 benign vs 2 pathogenic), and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.823549Disordered0.919118Binding0.2990.9030.750-5.035Likely Benign0.698Likely PathogenicLikely Benign0.126Likely Benign-1.42Neutral0.943Possibly Damaging0.755Possibly Damaging2.41Pathogenic0.49Tolerated0.13310.7427210.0-0.98
c.2959G>C
D987H
2D
AIThe SynGAP1 missense variant D987H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL and ESM1b, whereas a majority of tools (PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default) predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Pathogenic. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, SGM‑Consensus as Likely Pathogenic, and the Foldetta stability analysis is unavailable. Based on the preponderance of pathogenic predictions and the SGM‑Consensus result, the variant is most likely pathogenic, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.823549Disordered0.919118Binding0.2990.9030.750-5.580Likely Benign0.925Likely PathogenicAmbiguous0.249Likely Benign-3.16Deleterious0.998Probably Damaging0.951Probably Damaging2.35Pathogenic0.02Affected0.15530.76291-10.322.05
c.2959G>T
D987Y
2D
AIThe SynGAP1 missense variant D987Y is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Functional prediction tools cluster into two groups: benign predictions come from REVEL and ESM1b, whereas pathogenic predictions are made by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. The high‑accuracy consensus, SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, resolves as likely pathogenic (3 pathogenic vs 1 benign). AlphaMissense‑Optimized returns an uncertain result, and Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a pathogenic effect, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.823549Disordered0.919118Binding0.2990.9030.750-6.208Likely Benign0.831Likely PathogenicAmbiguous0.274Likely Benign-4.41Deleterious0.999Probably Damaging0.966Probably Damaging2.33Pathogenic0.01Affected0.06320.6818-4-32.248.09
c.295G>A
E99K
2D
AIThe SynGAP1 E99K missense variant is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote) also as benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar reporting, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.645246Binding0.3250.8740.500-4.746Likely Benign0.678Likely PathogenicLikely Benign0.071Likely Benign-0.88Neutral0.000Benign0.000Benign4.14Benign0.00Affected0.27520.814901-0.4-0.94
c.295G>C
E99Q
2D
AIThe SynGAP1 missense variant E99Q is reported in gnomAD (6-33425903‑G‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign impact for E99Q, and this conclusion is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.645246Binding0.3250.8740.5006-33425903-G-C16.20e-7-3.675Likely Benign0.325Likely BenignLikely Benign0.056Likely Benign-0.82Neutral0.001Benign0.000Benign4.10Benign0.00Affected4.3210.16720.7727220.0-0.98
c.2960A>C
D987A
2D
AIThe SynGAP1 D987A missense variant is not reported in ClinVar and has no gnomAD entry. Consensus prediction tools that classify the change as benign include REVEL and ESM1b, whereas the majority of other in silico predictors (PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default) and the SGM‑Consensus score (Likely Pathogenic) indicate a pathogenic effect. Grouping by agreement, benign predictions are limited to two tools, while pathogenic predictions are supported by seven distinct algorithms. High‑accuracy assessments further clarify the picture: AlphaMissense‑Optimized returns an uncertain result, SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a Likely Pathogenic classification, and the protein‑folding stability method Foldetta is unavailable for this variant. Overall, the preponderance of evidence points to a pathogenic impact, and this conclusion does not conflict with the absence of a ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.823549Disordered0.919118Binding0.2990.9030.750-4.880Likely Benign0.853Likely PathogenicAmbiguous0.261Likely Benign-3.72Deleterious0.943Possibly Damaging0.686Possibly Damaging2.39Pathogenic0.02Affected0.39300.68460-25.3-44.01
c.2960A>T
D987V
2D
AIThe SynGAP1 missense variant D987V is not reported in ClinVar and has no entries in gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL and ESM1b, while pathogenic predictions are made by PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments further support a deleterious effect: AlphaMissense‑Optimized is uncertain, but the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—labels the variant as Likely Pathogenic. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence indicates that D987V is most likely pathogenic, and this conclusion is not contradicted by ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.823549Disordered0.919118Binding0.2990.9030.750-4.647Likely Benign0.857Likely PathogenicAmbiguous0.389Likely Benign-4.01Deleterious0.992Probably Damaging0.913Probably Damaging2.34Pathogenic0.00Affected0.09070.7202-2-37.7-15.96
c.2961C>A
D987E
2D
AIThe SynGAP1 missense variant D987E is reported in gnomAD (6‑33443513‑C‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of predictions points to a benign effect, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.823549Disordered0.919118Binding0.2990.9030.7506-33443513-C-A16.20e-7-4.406Likely Benign0.425AmbiguousLikely Benign0.124Likely Benign-1.36Neutral0.049Benign0.044Benign2.64Benign0.04Affected4.3220.15860.7239230.014.03
c.2961C>G
D987E
2D
AIThe SynGAP1 missense variant D987E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus indicates Likely Benign, and Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign effect for D987E, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.823549Disordered0.919118Binding0.2990.9030.750-4.406Likely Benign0.425AmbiguousLikely Benign0.124Likely Benign-1.36Neutral0.049Benign0.044Benign2.64Benign0.04Affected4.3220.15860.7239230.014.03
c.2962C>A
L988I
2D
AIThe SynGAP1 missense variant L988I is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.827927Disordered0.918781Binding0.3600.9130.750-4.226Likely Benign0.204Likely BenignLikely Benign0.120Likely Benign-1.08Neutral0.924Possibly Damaging0.652Possibly Damaging2.70Benign0.00Affected0.10340.4143220.70.00
c.2962C>G
L988V
2D
AIThe SynGAP1 missense variant L988V is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized returns Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability prediction is available. Overall, the majority of evidence points to a benign effect for L988V, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.827927Disordered0.918781Binding0.3600.9130.750-3.626Likely Benign0.226Likely BenignLikely Benign0.096Likely Benign-1.42Neutral0.856Possibly Damaging0.474Possibly Damaging2.73Benign0.00Affected0.16520.3793210.4-14.03
c.2963T>A
L988H
2D
AIThe SynGAP1 missense variant L988H is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 vs 2). Foldetta results are unavailable. Overall, the majority of predictions (five pathogenic vs four benign) lean toward pathogenicity. Thus, the variant is most likely pathogenic, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.827927Disordered0.918781Binding0.3600.9130.750-4.779Likely Benign0.733Likely PathogenicLikely Benign0.179Likely Benign-2.70Deleterious0.998Probably Damaging0.947Probably Damaging2.62Benign0.00Affected0.11790.1414-2-3-7.023.98
c.2963T>C
L988P
2D
AIThe SynGAP1 missense variant L988P is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (2 pathogenic vs. 2 benign). Foldetta results are unavailable. Overall, the majority of predictions (five pathogenic vs. four benign) lean toward pathogenicity. Thus, the variant is most likely pathogenic, and this conclusion does not contradict any existing ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.827927Disordered0.918781Binding0.3600.9130.750-3.848Likely Benign0.703Likely PathogenicLikely Benign0.216Likely Benign-2.96Deleterious0.977Probably Damaging0.900Possibly Damaging2.62Benign0.00Affected0.32820.1698-3-3-5.4-16.04
c.2963T>G
L988R
2D
AIThe SynGAP1 missense variant L988R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.827927Disordered0.918781Binding0.3600.9130.750-4.412Likely Benign0.681Likely PathogenicLikely Benign0.202Likely Benign-2.39Neutral0.954Possibly Damaging0.867Possibly Damaging2.69Benign0.00Affected0.12570.1088-3-2-8.343.03
c.2965T>A
S989T
2D
AIThe SynGAP1 missense variant S989T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and SIFT—suggest a pathogenic impact. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also reports a benign outcome. No Foldetta stability data are available. Overall, the majority of evidence points to a benign effect, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.908835Binding0.2960.9110.750-3.995Likely Benign0.118Likely BenignLikely Benign0.059Likely Benign-1.48Neutral0.770Possibly Damaging0.396Benign2.66Benign0.00Affected0.11830.5377110.114.03
c.2965T>C
S989P
2D
AIThe SynGAP1 missense variant S989P is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is likely benign; Foldetta results are unavailable. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.908835Binding0.2960.9110.750-2.688Likely Benign0.209Likely BenignLikely Benign0.147Likely Benign-2.48Neutral0.010Benign0.015Benign2.67Benign0.00Affected0.16900.49411-1-0.810.04
c.2965T>G
S989A
2D
AIThe SynGAP1 missense variant S989A is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.908835Binding0.2960.9110.750-3.495Likely Benign0.089Likely BenignLikely Benign0.083Likely Benign-1.15Neutral0.580Possibly Damaging0.253Benign2.68Benign0.00Affected0.45800.4221112.6-16.00
c.2966C>A
S989Y
2D
AIThe SynGAP1 missense variant S989Y is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. High‑accuracy predictions therefore indicate a benign outcome: AlphaMissense‑Optimized is benign, the SGM Consensus is benign, and Foldetta data are unavailable. Consequently, the variant is most likely benign based on the current computational evidence, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.795062Disordered0.908835Binding0.2960.9110.750-4.774Likely Benign0.471AmbiguousLikely Benign0.103Likely Benign-3.32Deleterious0.986Probably Damaging0.876Possibly Damaging2.60Benign0.00Affected0.06110.4815-3-2-0.576.10
c.2966C>G
S989C
2D
AIThe SynGAP1 missense variant S989C is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, SGM‑Consensus as Likely Benign, while Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.908835Binding0.2960.9110.750-5.889Likely Benign0.160Likely BenignLikely Benign0.080Likely Benign-2.88Deleterious0.996Probably Damaging0.905Possibly Damaging2.59Benign0.00Affected0.08280.52020-13.316.06
c.2966C>T
S989F
2D
AIThe SynGAP1 missense variant S989F is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also predicts benign, and Foldetta results are unavailable. Overall, the majority of reliable predictors and the consensus high‑accuracy tools indicate a benign impact. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.795062Disordered0.908835Binding0.2960.9110.750-4.115Likely Benign0.435AmbiguousLikely Benign0.109Likely Benign-3.35Deleterious0.986Probably Damaging0.876Possibly Damaging2.60Benign0.00Affected0.05980.5103-3-23.660.10
c.2968T>A
S990T
2D
AIThe SynGAP1 missense variant S990T is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.902387Binding0.3010.9190.750-4.439Likely Benign0.073Likely BenignLikely Benign0.026Likely Benign-0.06Neutral0.001Benign0.007Benign2.89Benign1.00Tolerated0.15240.5598110.114.03
c.2968T>C
S990P
2D
AIThe SynGAP1 missense variant S990P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign impact, and this is consistent with the lack of any ClinVar pathogenic annotation. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.902387Binding0.3010.9190.750-3.150Likely Benign0.122Likely BenignLikely Benign0.117Likely Benign-1.95Neutral0.586Possibly Damaging0.377Benign2.74Benign0.01Affected0.19100.53451-1-0.810.04
c.2968T>G
S990A
2D
AIThe SynGAP1 missense variant S990A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. Foldetta results are unavailable. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.902387Binding0.3010.9190.750-3.554Likely Benign0.063Likely BenignLikely Benign0.020Likely Benign-0.51Neutral0.001Benign0.004Benign2.91Benign0.03Affected0.45370.4509112.6-16.00
c.2969C>A
S990Y
2D
AIThe SynGAP1 missense variant S990Y is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, SGM‑Consensus as Likely Benign, and Foldetta results are unavailable. Taken together, the majority of evidence points to a benign impact. The predictions do not contradict the ClinVar status, which has no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.902387Binding0.3010.9190.750-4.272Likely Benign0.314Likely BenignLikely Benign0.131Likely Benign-2.52Deleterious0.832Possibly Damaging0.500Possibly Damaging2.74Benign0.00Affected0.08930.5832-3-2-0.576.10
c.2969C>G
S990C
2D
AIThe SynGAP1 missense variant S990C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for S990C, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.902387Binding0.3010.9190.750-5.753Likely Benign0.109Likely BenignLikely Benign0.112Likely Benign-1.91Neutral0.938Possibly Damaging0.690Possibly Damaging2.73Benign0.01Affected0.10410.58230-13.316.06
c.2969C>T
S990F
2D
AIThe SynGAP1 missense variant S990F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; no Foldetta stability result is available. Overall, the majority of evidence points to a benign impact for S990F. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical databases.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.902387Binding0.3010.9190.750-4.253Likely Benign0.290Likely BenignLikely Benign0.107Likely Benign-2.65Deleterious0.710Possibly Damaging0.272Benign2.75Benign0.00Affected0.08140.6021-3-23.660.10
c.296A>C
E99A
2D
AIThe SynGAP1 E99A missense change is not reported in ClinVar and has no entry in gnomAD. Consensus‑based predictors cluster around a benign interpretation: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all score the variant as benign, while only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” verdict. AlphaMissense‑Default remains uncertain, and no Foldetta stability assessment is available. High‑accuracy tools therefore converge on a benign prediction: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and Foldetta data are missing. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.645246Binding0.3250.8740.500-3.173Likely Benign0.347AmbiguousLikely Benign0.127Likely Benign-1.49Neutral0.000Benign0.000Benign4.07Benign0.00Affected0.42450.75480-15.3-58.04
c.296A>G
E99G
2D
AIThe SynGAP1 missense variant E99G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.645246Binding0.3250.8740.500-3.031Likely Benign0.259Likely BenignLikely Benign0.145Likely Benign-1.69Neutral0.000Benign0.000Benign4.04Benign0.00Affected0.30480.63990-23.1-72.06
c.296A>T
E99V
2D
AIThe SynGAP1 missense variant E99V is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores benign, and the SGM‑Consensus likewise reports Likely Benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign effect for E99V, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.645246Binding0.3250.8740.500-3.628Likely Benign0.544AmbiguousLikely Benign0.208Likely Benign-1.69Neutral0.000Benign0.000Benign4.02Benign0.00Affected0.11090.8175-2-27.7-29.98
c.2971G>C
G991R
2D
AIThe SynGAP1 missense variant G991R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the majority of evidence points to a benign effect for G991R, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.911393Binding0.2860.9200.750-3.934Likely Benign0.411AmbiguousLikely Benign0.106Likely Benign-1.20Neutral0.984Probably Damaging0.772Possibly Damaging4.11Benign0.01Affected4.3220.09560.4181-3-2-4.199.14
c.2971G>T
G991W
2D
AIThe SynGAP1 missense variant G991W is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the overall assessment. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.911393Binding0.2860.9200.750-6.281Likely Benign0.336Likely BenignLikely Benign0.124Likely Benign-2.32Neutral0.997Probably Damaging0.975Probably Damaging4.07Benign0.00Affected0.07450.3654-7-2-0.5129.16
c.2972G>A
G991E
2D
AIThe SynGAP1 missense variant G991E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic outcome. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized independently predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence—including the high‑accuracy tools—points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.911393Binding0.2860.9200.750-4.729Likely Benign0.341AmbiguousLikely Benign0.065Likely Benign-1.30Neutral0.846Possibly Damaging0.697Possibly Damaging4.13Benign0.01Affected0.14800.42770-2-3.172.06
c.2972G>C
G991A
2D
AIThe SynGAP1 missense variant G991A is catalogued in gnomAD (ID 6‑33443524‑G‑C) and has no ClinVar entry. All evaluated in silico predictors report a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized are unanimous in predicting benign. No tool indicates pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign,” while Foldetta results are unavailable. Consequently, the variant is most likely benign based on current predictions, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.911393Binding0.2860.9200.7506-33443524-G-C16.20e-7-3.585Likely Benign0.073Likely BenignLikely Benign0.064Likely Benign-0.83Neutral0.002Benign0.026Benign4.20Benign0.62Tolerated4.3220.35220.4528012.214.03
c.2972G>T
G991V
2D
AIThe SynGAP1 missense variant G991V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.911393Binding0.2860.9200.750-4.129Likely Benign0.098Likely BenignLikely Benign0.064Likely Benign-1.61Neutral0.440Benign0.253Benign4.16Benign0.01Affected0.11480.3961-1-34.642.08
c.2974G>A
V992I
2D
AIThe SynGAP1 missense variant V992I is catalogued in gnomAD (ID 6‑33443526‑G‑A) but has no ClinVar entry. Across a broad panel of in silico predictors, every tool reports a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as tolerated or benign. No tool in the set indicates pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a Likely Benign verdict. Foldetta results are not available for this variant. Consequently, the variant is most likely benign, and this prediction does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.921728Binding0.3310.9170.7506-33443526-G-A53.10e-6-3.851Likely Benign0.074Likely BenignLikely Benign0.052Likely Benign-0.30Neutral0.302Benign0.089Benign4.20Benign0.29Tolerated4.3220.09390.4541340.314.03
c.2974G>C
V992L
2D
AIThe SynGAP1 missense variant V992L is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the evidence strongly supports a benign classification, and this conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.921728Binding0.3310.9170.750-2.333Likely Benign0.086Likely BenignLikely Benign0.060Likely Benign-0.50Neutral0.086Benign0.038Benign4.24Benign0.16Tolerated0.12110.520221-0.414.03
c.2974G>T
V992F
2D
AIThe SynGAP1 missense variant V992F is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and SIFT—suggest a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and there is no conflict with ClinVar status, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.921728Binding0.3310.9170.750-3.131Likely Benign0.104Likely BenignLikely Benign0.083Likely Benign-1.25Neutral0.680Possibly Damaging0.356Benign4.17Benign0.04Affected0.08320.4083-1-1-1.448.04
c.2975T>A
V992D
2D
AIThe SynGAP1 missense variant V992D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only SIFT predicts pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the consensus of the majority of tools, including the high‑accuracy methods, indicates that V992D is most likely benign, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.921728Binding0.3310.9170.750-3.976Likely Benign0.306Likely BenignLikely Benign0.029Likely Benign-1.24Neutral0.302Benign0.158Benign4.21Benign0.05Affected0.16450.1056-2-3-7.715.96
c.2975T>C
V992A
2D
AIThe SynGAP1 missense variant V992A is not reported in ClinVar and is absent from gnomAD. Prediction tools that assess pathogenicity all converge on a benign outcome: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. No tool in the dataset indicates a pathogenic effect. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Based on the collective predictions, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.921728Binding0.3310.9170.750-2.607Likely Benign0.082Likely BenignLikely Benign0.069Likely Benign-0.08Neutral0.000Benign0.003Benign4.29Benign0.41Tolerated0.30410.266800-2.4-28.05
c.2975T>G
V992G
2D
AIThe SynGAP1 missense variant V992G is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). All available in silico predictors classify the variant as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity, so the benign group includes every listed predictor, while the pathogenic group is empty. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign; the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields a benign verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence overwhelmingly supports a benign effect, and this conclusion does not contradict any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.754692Disordered0.921728Binding0.3310.9170.750-1.906Likely Benign0.080Likely BenignLikely Benign0.067Likely Benign-0.28Neutral0.056Benign0.086Benign4.21Benign0.16Tolerated0.21140.2612-1-3-4.6-42.08
c.2977C>A
P993T
2D
AIThe SynGAP1 missense variant P993T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.923979Binding0.3190.9080.750-4.444Likely Benign0.061Likely BenignLikely Benign0.053Likely Benign-0.65Neutral0.001Benign0.010Benign4.32Benign0.04Affected0.16030.57890-10.93.99
c.2977C>G
P993A
2D
AIThe SynGAP1 missense variant P993A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign. Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.923979Binding0.3190.9080.750-4.030Likely Benign0.052Likely BenignLikely Benign0.036Likely Benign-0.46Neutral0.001Benign0.006Benign4.26Benign0.07Tolerated0.34870.49911-13.4-26.04
c.2977C>T
P993S
2D
AIThe SynGAP1 missense variant P993S is reported in gnomAD (ID 6‑33443529‑C‑T) and has no ClinVar entry. All evaluated in silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are unavailable. Based on the unanimous benign predictions and lack of ClinVar pathogenicity, the variant is most likely benign and does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.923979Binding0.3190.9080.7506-33443529-C-T31.86e-6-3.665Likely Benign0.068Likely BenignLikely Benign0.054Likely Benign-0.13Neutral0.011Benign0.023Benign4.26Benign0.59Tolerated4.3220.34210.5465-110.8-10.04
c.2978C>A
P993H
2D
AIThe SynGAP1 missense variant P993H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for P993H, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.923979Binding0.3190.9080.750-4.535Likely Benign0.119Likely BenignLikely Benign0.053Likely Benign-0.93Neutral0.938Possibly Damaging0.819Possibly Damaging4.11Benign0.00Affected0.17990.45910-2-1.640.02
c.2978C>G
P993R
2D
AIThe SynGAP1 missense variant P993R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized returns Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability prediction is available. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.923979Binding0.3190.9080.750-3.508Likely Benign0.158Likely BenignLikely Benign0.048Likely Benign-0.85Neutral0.586Possibly Damaging0.478Possibly Damaging4.14Benign0.01Affected0.14690.31220-2-2.959.07
c.2978C>T
P993L
2D
AIThe SynGAP1 missense variant P993L is reported in ClinVar as “Not listed” and is not present in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which contains no pathogenic assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.923979Binding0.3190.9080.750-3.581Likely Benign0.098Likely BenignLikely Benign0.028Likely Benign-1.37Neutral0.224Benign0.138Benign4.14Benign0.01Affected0.22990.6697-3-35.416.04
c.297A>C
E99D
2D
AIThe SynGAP1 missense variant E99D is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that E99D is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.645246Binding0.3250.8740.500-3.323Likely Benign0.063Likely BenignLikely Benign0.101Likely Benign-0.78Neutral0.000Benign0.000Benign4.09Benign0.00Affected0.23600.5200320.0-14.03
c.297A>T
E99D
2D
AIThe SynGAP1 missense variant E99D is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that E99D is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.645246Binding0.3250.8740.500-3.323Likely Benign0.063Likely BenignLikely Benign0.101Likely Benign-0.78Neutral0.000Benign0.000Benign4.09Benign0.00Affected0.23600.5200320.0-14.03
c.2980A>C
K994Q
2D
AIThe SynGAP1 missense variant K994Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.930054Binding0.2890.9120.750-1.947Likely Benign0.124Likely BenignLikely Benign0.105Likely Benign-0.45Neutral0.002Benign0.004Benign4.16Benign0.03Affected0.49750.1889110.4-0.04
c.2980A>G
K994E
2D
AIThe SynGAP1 missense variant K994E is reported in gnomAD (variant ID 6‑33443532‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the consensus of the majority of tools, including the high‑accuracy methods, points to a benign impact. This prediction does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.930054Binding0.2890.9120.7506-33443532-A-G16.20e-7-2.587Likely Benign0.339Likely BenignLikely Benign0.057Likely Benign-0.58Neutral0.036Benign0.039Benign4.14Benign0.02Affected4.3220.41480.1699100.40.94
c.2981A>C
K994T
2D
AIThe SynGAP1 missense variant K994T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Taken together, the majority of evidence points to a benign effect. There is no conflict with ClinVar status, as no ClinVar classification exists for this variant. Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.930054Binding0.2890.9120.750-2.346Likely Benign0.226Likely BenignLikely Benign0.041Likely Benign-1.22Neutral0.144Benign0.085Benign4.09Benign0.01Affected0.25030.42480-13.2-27.07
c.2981A>G
K994R
2D
AIThe SynGAP1 missense variant K994R is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.930054Binding0.2890.9120.750-1.990Likely Benign0.076Likely BenignLikely Benign0.071Likely Benign0.02Neutral0.001Benign0.001Benign4.21Benign0.47Tolerated0.50640.1657Weaken32-0.628.01
c.2981A>T
K994M
2D
AIThe SynGAP1 missense variant K994M is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign. Pathogenicity is suggested only by polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus (SGM‑Consensus) classifies the variant as likely benign, and AlphaMissense‑Optimized also predicts benign. No Foldetta stability analysis is available. Overall, the majority of evidence points to a benign impact, and this assessment does not conflict with ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.930054Binding0.2890.9120.750-2.974Likely Benign0.424AmbiguousLikely Benign0.057Likely Benign-1.21Neutral0.589Possibly Damaging0.187Benign4.04Benign0.00Affected0.16120.43950-15.83.02
c.2982G>C
K994N
2D
AIThe SynGAP1 missense variant K994N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic call comes from SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, SGM‑Consensus confirms a Likely Benign status, and Foldetta data are unavailable. Taken together, the preponderance of evidence indicates that K994N is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.930054Binding0.2890.9120.750-3.724Likely Benign0.519AmbiguousLikely Benign0.011Likely Benign-0.73Neutral0.255Benign0.113Benign4.09Benign0.01Affected0.40100.2376100.4-14.07
c.2982G>T
K994N
2D
AIThe SynGAP1 missense variant K994N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic call comes from SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, SGM‑Consensus confirms a Likely Benign status, and Foldetta data are unavailable. Taken together, the preponderance of evidence indicates that K994N is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.930054Binding0.2890.9120.750-3.724Likely Benign0.519AmbiguousLikely Benign0.009Likely Benign-0.73Neutral0.255Benign0.113Benign4.09Benign0.01Affected0.40100.2376100.4-14.07
c.2983C>A
P995T
2D
AIThe SynGAP1 missense variant P995T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect for P995T, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.935305Binding0.3380.9020.750-5.148Likely Benign0.058Likely BenignLikely Benign0.034Likely Benign-1.15Neutral0.224Benign0.096Benign4.19Benign0.00Affected0.14670.56670-10.93.99
c.2983C>G
P995A
2D
AIThe SynGAP1 missense variant P995A is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) indicates likely benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the majority of evidence points to a benign impact for P995A, and this conclusion is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.935305Binding0.3380.9020.750-4.465Likely Benign0.051Likely BenignLikely Benign0.055Likely Benign-1.02Neutral0.001Benign0.008Benign4.22Benign0.00Affected0.32870.48411-13.4-26.04
c.2984C>A
P995H
2D
AIThe SynGAP1 missense variant P995H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for P995H, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.935305Binding0.3380.9020.750-5.347Likely Benign0.107Likely BenignLikely Benign0.044Likely Benign-0.75Neutral0.832Possibly Damaging0.600Possibly Damaging4.16Benign0.00Affected0.16180.45710-2-1.640.02
c.2984C>G
P995R
2D
AIThe SynGAP1 missense variant P995R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv and SIFT predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. The variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.935305Binding0.3380.9020.750-4.605Likely Benign0.141Likely BenignLikely Benign0.089Likely Benign-1.06Neutral0.586Possibly Damaging0.304Benign4.18Benign0.00Affected0.13700.34240-2-2.959.07
c.2984C>T
P995L
2D
AIThe SynGAP1 missense variant P995L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta results are not available for this variant. Overall, the majority of evidence points to a benign effect, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.935305Binding0.3380.9020.750-4.948Likely Benign0.081Likely BenignLikely Benign0.063Likely Benign-1.03Neutral0.411Benign0.096Benign4.16Benign0.00Affected0.22940.6324-3-35.416.04
c.2986C>A
P996T
2D
AIThe SynGAP1 missense variant P996T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.775545Disordered0.942262Binding0.3120.9000.750-5.138Likely Benign0.058Likely BenignLikely Benign0.062Likely Benign-0.71Neutral0.036Benign0.039Benign4.26Benign0.03Affected0.14180.61630-10.93.99
c.2986C>G
P996A
2D
AIThe SynGAP1 missense variant P996A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools that assess sequence conservation and structural impact uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the collective evidence strongly supports a benign classification, and this conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.775545Disordered0.942262Binding0.3120.9000.750-4.596Likely Benign0.045Likely BenignLikely Benign0.086Likely Benign-0.40Neutral0.000Benign0.002Benign4.30Benign0.86Tolerated0.32420.49611-13.4-26.04
c.2986C>T
P996S
2D
AIThe SynGAP1 missense variant P996S is reported in gnomAD (ID 6‑33443538‑C‑T) and has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions is benign, and this is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.775545Disordered0.942262Binding0.3120.9000.7506-33443538-C-T42.48e-6-4.461Likely Benign0.063Likely BenignLikely Benign0.064Likely Benign-0.58Neutral0.002Benign0.004Benign4.30Benign0.09Tolerated4.3240.31710.5161-110.8-10.04
c.2987C>A
P996H
2D
AIThe SynGAP1 missense variant P996H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.775545Disordered0.942262Binding0.3120.9000.750-5.554Likely Benign0.103Likely BenignLikely Benign0.045Likely Benign-1.19Neutral0.001Benign0.003Benign4.25Benign0.00Affected0.15850.51600-2-1.640.02
c.2987C>T
P996L
2D
AIThe SynGAP1 missense variant P996L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect; there is no conflict with ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.775545Disordered0.942262Binding0.3120.9000.750-5.302Likely Benign0.083Likely BenignLikely Benign0.045Likely Benign-1.65Neutral0.000Benign0.001Benign4.25Benign0.02Affected0.20570.6631-3-35.416.04
c.2989G>C
A997P
2D
AIThe SynGAP1 missense variant A997P is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the majority of evidence points to a benign impact, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.948624Binding0.2730.9010.500-2.014Likely Benign0.074Likely BenignLikely Benign0.092Likely Benign-1.17Neutral0.001Benign0.003Benign4.11Benign0.00Affected0.19380.52941-1-3.426.04
c.2989G>T
A997S
2D
AIThe SynGAP1 missense variant A997S is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic call comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.948624Binding0.2730.9010.500-3.362Likely Benign0.080Likely BenignLikely Benign0.097Likely Benign-0.63Neutral0.224Benign0.066Benign4.18Benign0.00Affected0.26610.569411-2.616.00
c.298T>A
Y100N
2D
AIThe SynGAP1 missense variant Y100N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.699094Disordered0.675421Binding0.3410.8800.625-2.579Likely Benign0.109Likely BenignLikely Benign0.183Likely Benign-0.66Neutral0.675Possibly Damaging0.099Benign4.23Benign0.00Affected0.24870.0373-2-2-2.2-49.07
c.298T>C
Y100H
2D
AIThe SynGAP1 missense variant Y100H is reported in gnomAD (variant ID 6-33432163‑T‑C) but has no ClinVar entry. Functional prediction tools cluster into two groups: the benign‑predicted set includes REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; the pathogenic‑predicted set contains polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments reinforce the benign classification: AlphaMissense‑Optimized predicts benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields a benign verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Overall, the consensus of available predictions indicates that Y100H is most likely benign, and this conclusion is not contradicted by any ClinVar status (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.699094Disordered0.675421Binding0.3410.8800.6256-33432163-T-C16.20e-7-2.094Likely Benign0.201Likely BenignLikely Benign0.123Likely Benign-0.40Neutral0.978Probably Damaging0.500Possibly Damaging4.23Benign0.00Affected4.3210.26500.031320-1.9-26.03
c.298T>G
Y100D
2D
AIThe SynGAP1 missense variant Y100D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.699094Disordered0.675421Binding0.3410.8800.625-1.269Likely Benign0.215Likely BenignLikely Benign0.233Likely Benign-1.01Neutral0.003Benign0.003Benign4.22Benign0.00Affected0.44650.0373-4-3-2.2-48.09
c.2990C>A
A997D
2D
AIThe SynGAP1 missense variant A997D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign. Foldetta results are not available for this variant. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of any ClinVar pathogenic annotation. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.948624Binding0.2730.9010.500-5.251Likely Benign0.319Likely BenignLikely Benign0.131Likely Benign-1.09Neutral0.411Benign0.120Benign4.15Benign0.00Affected0.18150.21430-2-5.344.01
c.2990C>G
A997G
2D
AIThe SynGAP1 missense variant A997G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.948624Binding0.2730.9010.500-3.424Likely Benign0.079Likely BenignLikely Benign0.041Likely Benign-0.82Neutral0.000Benign0.001Benign4.13Benign0.00Affected0.21450.474110-2.2-14.03
c.2990C>T
A997V
2D
AIThe SynGAP1 missense variant A997V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. The prediction is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.948624Binding0.2730.9010.500-4.504Likely Benign0.082Likely BenignLikely Benign0.052Likely Benign-1.01Neutral0.369Benign0.120Benign4.15Benign0.00Affected0.12320.6335002.428.05
c.2992G>A
A998T
2D
AIThe SynGAP1 missense variant A998T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. The variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.759478Disordered0.951758Binding0.3180.9020.500-3.909Likely Benign0.071Likely BenignLikely Benign0.067Likely Benign-0.97Neutral0.611Possibly Damaging0.321Benign4.11Benign0.00Affected0.16200.699410-2.530.03
c.2992G>C
A998P
2D
AIThe SynGAP1 missense variant A998P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. Foldetta results are unavailable. Overall, the majority of evidence, including the high‑accuracy tools, points to a benign effect for A998P. This conclusion does not contradict ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.759478Disordered0.951758Binding0.3180.9020.500-2.220Likely Benign0.071Likely BenignLikely Benign0.171Likely Benign-0.40Neutral0.971Probably Damaging0.690Possibly Damaging4.31Benign0.00Affected0.19240.51061-1-3.426.04
c.2992G>T
A998S
2D
AIThe SynGAP1 missense variant A998S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. The variant is therefore most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.759478Disordered0.951758Binding0.3180.9020.500-2.893Likely Benign0.074Likely BenignLikely Benign0.022Likely Benign-0.42Neutral0.611Possibly Damaging0.237Benign4.14Benign0.00Affected0.26740.550611-2.616.00
c.2993C>A
A998D
2D
AIThe SynGAP1 missense variant A998D is not reported in ClinVar and has no entry in gnomAD. Consensus from multiple in‑silico predictors shows a split: benign calls come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic calls arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default remains uncertain. The high‑accuracy assessment indicates that AlphaMissense‑Optimized predicts a benign effect, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports a likely benign outcome, and Foldetta data are unavailable. Overall, the majority of robust predictors lean toward a benign impact. Therefore, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.759478Disordered0.951758Binding0.3180.9020.500-5.481Likely Benign0.365AmbiguousLikely Benign0.122Likely Benign-1.55Neutral0.971Probably Damaging0.690Possibly Damaging4.09Benign0.00Affected0.17540.21430-2-5.344.01
c.2993C>G
A998G
2D
AIThe SynGAP1 missense variant A998G is not reported in ClinVar or gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate benign. Only two tools—polyPhen‑2 HumDiv and SIFT—suggest pathogenicity. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the available predictions points to a benign impact, and this is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.759478Disordered0.951758Binding0.3180.9020.500-3.173Likely Benign0.078Likely BenignLikely Benign0.032Likely Benign-1.29Neutral0.761Possibly Damaging0.396Benign4.13Benign0.00Affected0.22340.474110-2.2-14.03
c.2993C>T
A998V
2D
AIThe SynGAP1 missense variant A998V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and AlphaMissense‑Optimized also reports a benign prediction. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.759478Disordered0.951758Binding0.3180.9020.500-4.795Likely Benign0.101Likely BenignLikely Benign0.051Likely Benign-1.09Neutral0.245Benign0.138Benign4.09Benign0.00Affected0.12810.6147002.428.05
c.2995T>A
S999T
2D
AIThe SynGAP1 missense variant S999T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.950682Binding0.2620.8970.625-3.961Likely Benign0.088Likely BenignLikely Benign0.043Likely Benign-0.94Neutral0.625Possibly Damaging0.266Benign2.69Benign0.04Affected0.14690.6651110.114.03
c.2995T>C
S999P
2D
AIThe SynGAP1 missense variant S999P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign impact for S999P, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.950682Binding0.2620.8970.625-2.279Likely Benign0.095Likely BenignLikely Benign0.111Likely Benign-1.05Neutral0.966Probably Damaging0.773Possibly Damaging2.65Benign0.04Affected0.19630.62681-1-0.810.04
c.2995T>G
S999A
2D
AIThe SynGAP1 missense variant S999A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.950682Binding0.2620.8970.625-3.719Likely Benign0.075Likely BenignLikely Benign0.051Likely Benign-0.83Neutral0.005Benign0.016Benign2.71Benign0.81Tolerated0.45160.5434112.6-16.00
c.2996C>A
S999Y
2D
AIThe SynGAP1 missense variant S999Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for S999Y, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.950682Binding0.2620.8970.625-6.446Likely Benign0.346AmbiguousLikely Benign0.069Likely Benign-1.74Neutral0.934Possibly Damaging0.559Possibly Damaging2.64Benign0.00Affected0.08810.6249-3-2-0.576.10
c.2996C>G
S999C
2D
AIThe SynGAP1 missense variant S999C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. ESM1b is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for S999C, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.950682Binding0.2620.8970.625-7.751In-Between0.139Likely BenignLikely Benign0.049Likely Benign-1.68Neutral0.991Probably Damaging0.873Possibly Damaging2.63Benign0.01Affected0.11310.62120-13.316.06
c.2996C>T
S999F
2D
AIThe SynGAP1 missense variant S999F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized independently predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect; this is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.950682Binding0.2620.8970.625-6.206Likely Benign0.368AmbiguousLikely Benign0.072Likely Benign-1.79Neutral0.966Probably Damaging0.837Possibly Damaging2.64Benign0.01Affected0.08650.6337-3-23.660.10
c.2998A>C
I1000L
2D
AIThe SynGAP1 missense variant I1000L is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.957020Binding0.2930.9040.625-2.103Likely Benign0.117Likely BenignLikely Benign0.083Likely Benign-0.34Neutral0.211Benign0.108Benign2.76Benign0.70Tolerated0.09160.403422-0.70.00
c.2998A>T
I1000F
2D
AIThe SynGAP1 missense variant I1000F is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of predictions indicates that I1000F is most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.957020Binding0.2930.9040.625-3.801Likely Benign0.201Likely BenignLikely Benign0.147Likely Benign-1.02Neutral0.968Probably Damaging0.713Possibly Damaging2.70Benign0.13Tolerated0.05940.325910-1.734.02
c.2999T>A
I1000N
2D
AIThe SynGAP1 missense variant I1000N is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present). Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.957020Binding0.2930.9040.625-5.246Likely Benign0.677Likely PathogenicLikely Benign0.145Likely Benign-0.82Neutral0.995Probably Damaging0.913Probably Damaging2.72Benign0.16Tolerated0.10010.0900-2-3-8.00.94
c.2999T>C
I1000T
2D
AIThe SynGAP1 missense variant I1000T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and there is no ClinVar status to contradict this conclusion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.957020Binding0.2930.9040.625-4.748Likely Benign0.721Likely PathogenicLikely Benign0.131Likely Benign-0.87Neutral0.896Possibly Damaging0.596Possibly Damaging2.78Benign0.29Tolerated0.10450.15940-1-5.2-12.05
c.2999T>G
I1000S
2D
AIThe SynGAP1 missense variant I1000S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM‑Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence (seven benign vs. three pathogenic predictions) supports a benign classification. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.957020Binding0.2930.9040.625-3.694Likely Benign0.587Likely PathogenicLikely Benign0.151Likely Benign-0.38Neutral0.946Possibly Damaging0.673Possibly Damaging2.80Benign0.19Tolerated0.25010.1270-1-2-5.3-26.08
c.299A>C
Y100S
2D
AIThe SynGAP1 missense variant Y100S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.699094Disordered0.675421Binding0.3410.8800.625-1.217Likely Benign0.129Likely BenignLikely Benign0.182Likely Benign-0.14Neutral0.675Possibly Damaging0.175Benign4.31Benign0.00Affected0.50660.1600Weaken-3-20.5-76.10
c.299A>G
Y100C
2D
AIThe SynGAP1 missense variant Y100C is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.699094Disordered0.675421Binding0.3410.8800.625-3.789Likely Benign0.117Likely BenignLikely Benign0.172Likely Benign-0.88Neutral0.994Probably Damaging0.816Possibly Damaging4.18Benign0.00Affected0.30730.22130-23.8-60.04
c.299A>T
Y100F
2D
AIThe SynGAP1 missense variant Y100F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.699094Disordered0.675421Binding0.3410.8800.625-3.056Likely Benign0.117Likely BenignLikely Benign0.139Likely Benign-0.50Neutral0.928Possibly Damaging0.222Benign4.21Benign0.00Affected0.27840.3087734.1-16.00
c.29G>T
R10L
2D
AIThe SynGAP1 missense variant R10L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta results are not available for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.513657Binding0.3300.9150.625-3.269Likely Benign0.244Likely BenignLikely Benign0.143Likely Benign0.09Neutral0.058Benign0.009Benign4.21Benign0.00Affected0.22550.5261-3-28.3-43.03
c.3000C>G
I1000M
2D
AIThe SynGAP1 missense variant I1000M is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.957020Binding0.2930.9040.625-3.541Likely Benign0.161Likely BenignLikely Benign0.035Likely Benign-0.32Neutral0.437Benign0.108Benign2.70Benign0.17Tolerated0.07690.310421-2.618.03
c.3001C>A
L1001I
2D
AIThe SynGAP1 missense variant L1001I is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. High‑accuracy consensus methods reinforce the benign assessment: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” No Foldetta stability prediction is available for this variant. Overall, the preponderance of evidence from both general and high‑accuracy tools points to a benign effect, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.958507Binding0.2690.9020.375-4.486Likely Benign0.076Likely BenignLikely Benign0.034Likely Benign-0.17Neutral0.022Benign0.018Benign2.69Benign0.00Affected0.09940.3264220.70.00
c.3001C>G
L1001V
2D
AIThe SynGAP1 missense variant L1001V is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized scores the variant as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the available predictions points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.958507Binding0.2690.9020.375-3.865Likely Benign0.075Likely BenignLikely Benign0.035Likely Benign-0.20Neutral0.022Benign0.008Benign2.71Benign0.00Affected0.15690.2714210.4-14.03
c.3001C>T
L1001F
2D
AIThe SynGAP1 missense variant L1001F is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while the SGM‑Consensus (derived from the majority of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT predict a pathogenic impact. High‑accuracy assessments reinforce the benign prediction: AlphaMissense‑Optimized scores benign, and the SGM‑Consensus (majority vote of the four high‑confidence tools) is benign; Foldetta data are unavailable. Overall, the preponderance of evidence supports a benign classification for L1001F, and this conclusion does not conflict with ClinVar, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.958507Binding0.2690.9020.375-4.712Likely Benign0.119Likely BenignLikely Benign0.026Likely Benign-0.85Neutral0.934Possibly Damaging0.617Possibly Damaging2.65Benign0.00Affected0.07030.287620-1.034.02
c.3002T>A
L1001H
2D
AIThe SynGAP1 missense variant L1001H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.958507Binding0.2690.9020.375-3.119Likely Benign0.258Likely BenignLikely Benign0.109Likely Benign-1.02Neutral0.997Probably Damaging0.870Possibly Damaging2.64Benign0.00Affected0.11410.0958-2-3-7.023.98
c.3002T>G
L1001R
2D
AIThe SynGAP1 missense variant L1001R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized returns Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.958507Binding0.2690.9020.375-2.285Likely Benign0.320Likely BenignLikely Benign0.091Likely Benign-1.09Neutral0.966Probably Damaging0.708Possibly Damaging2.67Benign0.00Affected0.12990.0832-3-2-8.343.03
c.3004C>A
H1002N
2D
AIThe SynGAP1 missense variant H1002N is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy methods reinforce the benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign, with no Foldetta data to contradict. Overall, the preponderance of evidence points to a benign effect for H1002N, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.953758Binding0.2850.9000.500-5.622Likely Benign0.466AmbiguousLikely Benign0.076Likely Benign-1.41Neutral0.801Possibly Damaging0.596Possibly Damaging2.76Benign1.00Tolerated0.20840.305721-0.3-23.04
c.3004C>G
H1002D
2D
AIThe SynGAP1 missense variant H1002D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, SGM‑Consensus as Likely Benign, and Foldetta results are unavailable. Overall, the balance of evidence leans toward a benign interpretation, with no conflict with ClinVar status because no ClinVar assertion exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.953758Binding0.2850.9000.500-6.511Likely Benign0.852Likely PathogenicAmbiguous0.218Likely Benign-2.09Neutral0.891Possibly Damaging0.673Possibly Damaging2.75Benign0.89Tolerated0.25970.23351-1-0.3-22.05
c.3004C>T
H1002Y
2D
AIThe SynGAP1 missense variant H1002Y is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in silico predictors indicates a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all score the change as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also classifies it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default tool remains uncertain, and no Foldetta stability assessment is available. High‑accuracy methods that are available—AlphaMissense‑Optimized and the SGM‑Consensus—both support a benign interpretation. Therefore, the variant is most likely benign based on the current predictive evidence, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.953758Binding0.2850.9000.500-6.159Likely Benign0.489AmbiguousLikely Benign0.181Likely Benign-1.85Neutral0.961Probably Damaging0.808Possibly Damaging2.74Benign0.14Tolerated0.12430.4427021.926.03
c.3005A>C
H1002P
2D
AIThe SynGAP1 missense variant H1002P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus likewise indicates Likely Benign. Foldetta results are unavailable, so they do not influence the overall assessment. Based on the majority of predictions and the high‑accuracy consensus, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.953758Binding0.2850.9000.500-4.616Likely Benign0.242Likely BenignLikely Benign0.213Likely Benign-2.02Neutral0.989Probably Damaging0.874Possibly Damaging2.77Benign0.28Tolerated0.20150.37380-21.6-40.02
c.3005A>G
H1002R
2D
AIThe SynGAP1 missense variant H1002R is listed in gnomAD (ID 6‑33443557‑A‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only AlphaMissense‑Default predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Taken together, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar classification (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.953758Binding0.2850.9000.5006-33443557-A-G16.20e-7-3.624Likely Benign0.609Likely PathogenicLikely Benign0.082Likely Benign-1.52Neutral0.012Benign0.022Benign2.76Benign0.25Tolerated4.3240.21600.297802-1.319.05
c.3005A>T
H1002L
2D
AIThe SynGAP1 H1002L missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation and the absence of the variant in population databases, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.784345Disordered0.953758Binding0.2850.9000.500-6.448Likely Benign0.556AmbiguousLikely Benign0.157Likely Benign-3.12Deleterious0.801Possibly Damaging0.602Possibly Damaging2.79Benign0.13Tolerated0.12960.5088-2-37.0-23.98
c.3006T>A
H1002Q
2D
AIThe SynGAP1 missense variant H1002Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. There is no ClinVar entry to contradict this assessment, so the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.953758Binding0.2850.9000.500-5.071Likely Benign0.650Likely PathogenicLikely Benign0.140Likely Benign-1.83Neutral0.801Possibly Damaging0.602Possibly Damaging2.77Benign0.23Tolerated0.19270.351030-0.3-9.01
c.3006T>G
H1002Q
2D
AIThe SynGAP1 missense variant H1002Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. There is no ClinVar entry to contradict this conclusion, so the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.953758Binding0.2850.9000.500-5.071Likely Benign0.650Likely PathogenicLikely Benign0.140Likely Benign-1.83Neutral0.801Possibly Damaging0.602Possibly Damaging2.77Benign0.23Tolerated0.19270.351030-0.3-9.01
c.3007A>C
S1003R
2D
AIThe SynGAP1 missense variant S1003R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, and ESM1b, whereas those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 vs 2), and Foldetta results are unavailable. Overall, the majority of evaluated tools (six pathogenic vs. three benign) indicate a pathogenic impact. This prediction aligns with the lack of ClinVar annotation and does not contradict any existing clinical classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.834292Disordered0.947349Binding0.2720.9010.625-5.113Likely Benign0.991Likely PathogenicLikely Pathogenic0.110Likely Benign-1.88Neutral0.999Probably Damaging0.996Probably Damaging2.48Pathogenic0.00Affected3.7750.11510.37460-1-3.769.11
c.3007A>G
S1003G
2D
AIThe SynGAP1 missense variant S1003G is catalogued in gnomAD (ID 6‑33443559‑A‑G) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect for S1003G, and this conclusion does not contradict any ClinVar status, as none is currently assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.834292Disordered0.947349Binding0.2720.9010.6256-33443559-A-G16.20e-7-5.888Likely Benign0.542AmbiguousLikely Benign0.088Likely Benign-1.72Neutral0.992Probably Damaging0.987Probably Damaging2.48Pathogenic0.00Affected3.7750.27300.4789010.4-30.03
c.3007A>T
S1003C
2D
AIThe SynGAP1 missense variant S1003C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that indicate a benign effect include REVEL, PROVEAN, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect include polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Default. The high‑accuracy consensus, SGM‑Consensus, is derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN and is classified as Likely Pathogenic. AlphaMissense‑Optimized, a high‑accuracy tool, predicts a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of predictions, including the high‑accuracy consensus, support a pathogenic classification, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.834292Disordered0.947349Binding0.2720.9010.625-8.058Likely Pathogenic0.647Likely PathogenicLikely Benign0.141Likely Benign-1.98Neutral1.000Probably Damaging0.998Probably Damaging2.45Pathogenic0.00Affected0.14420.59660-13.316.06
c.3008G>A
S1003N
2D
AIThe SynGAP1 missense variant S1003N is not reported in ClinVar (ClinVar status: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, and ESM1b, whereas those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments are mixed: AlphaMissense‑Optimized is uncertain; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a 2‑vs‑2 split, and Foldetta results are unavailable. Overall, more tools (five) predict pathogenicity than benign (three), and the high‑accuracy methods do not overturn this trend. Therefore, the variant is most likely pathogenic based on current predictions, and this assessment does not contradict any ClinVar status because the variant has not been reported there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.834292Disordered0.947349Binding0.2720.9010.625-5.175Likely Benign0.889Likely PathogenicAmbiguous0.122Likely Benign-1.37Neutral0.997Probably Damaging0.992Probably Damaging2.48Pathogenic0.00Affected0.17980.502911-2.727.03
c.3008G>C
S1003T
2D
AIThe SynGAP1 missense variant S1003T is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority of pathogenic predictors—polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT—suggest a damaging impact. The AlphaMissense‑Default score is uncertain, and Foldetta stability analysis is unavailable. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign outcome. High‑accuracy assessments therefore lean toward a benign interpretation: AlphaMissense‑Optimized predicts benign, SGM‑Consensus is likely benign, and no Foldetta data is present. Overall, the computational evidence supports a benign classification, with no conflict with ClinVar status because no ClinVar assertion exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.947349Binding0.2720.9010.625-5.140Likely Benign0.493AmbiguousLikely Benign0.115Likely Benign-1.04Neutral0.992Probably Damaging0.987Probably Damaging2.51Benign0.00Affected0.18640.6227110.114.03
c.3008G>T
S1003I
2D
AIThe SynGAP1 missense variant S1003I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, and FATHMM. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, and AlphaMissense‑Default. The high‑accuracy consensus methods give mixed results: AlphaMissense‑Optimized is uncertain; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (two pathogenic, two benign votes); and Foldetta (combining FoldX‑MD and Rosetta) has no available output. Based on the overall distribution of predictions, the variant is most likely pathogenic. This assessment does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.834292Disordered0.947349Binding0.2720.9010.625-8.952Likely Pathogenic0.954Likely PathogenicAmbiguous0.189Likely Benign-2.31Neutral0.999Probably Damaging0.998Probably Damaging2.50Benign0.00Affected0.12940.5735-1-25.326.08
c.3009C>A
S1003R
2D
AIThe SynGAP1 missense variant S1003R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, and ESM1b, whereas those that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 vs 2), and Foldetta results are unavailable. Overall, the majority of evaluated tools (six pathogenic vs. three benign) indicate a pathogenic impact. This prediction aligns with the lack of ClinVar annotation and does not contradict any existing clinical classification. Thus, the variant is most likely pathogenic.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.834292Disordered0.947349Binding0.2720.9010.625-5.113Likely Benign0.991Likely PathogenicLikely Pathogenic0.141Likely Benign-1.88Neutral0.999Probably Damaging0.996Probably Damaging2.48Pathogenic0.00Affected3.7750.11510.37460-1-3.769.11
c.3010C>A
H1004N
2D
AIThe SynGAP1 missense variant H1004N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. There is no ClinVar entry to contradict this assessment, so the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.808535Disordered0.943707Binding0.2710.9010.750-4.265Likely Benign0.601Likely PathogenicLikely Benign0.072Likely Benign-1.18Neutral0.997Probably Damaging0.992Probably Damaging2.88Benign0.35Tolerated0.20560.358021-0.3-23.04
c.3010C>G
H1004D
2D
AIThe SynGAP1 missense variant H1004D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, SGM‑Consensus as likely benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for H1004D. This conclusion is not contradicted by ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.808535Disordered0.943707Binding0.2710.9010.750-5.275Likely Benign0.913Likely PathogenicAmbiguous0.148Likely Benign-2.16Neutral0.997Probably Damaging0.994Probably Damaging2.78Benign0.29Tolerated0.26950.25301-1-0.3-22.05
c.3010C>T
H1004Y
2D
AIThe SynGAP1 missense variant H1004Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar status, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.808535Disordered0.943707Binding0.2710.9010.750-5.196Likely Benign0.676Likely PathogenicLikely Benign0.131Likely Benign-1.67Neutral0.997Probably Damaging0.992Probably Damaging2.72Benign0.49Tolerated0.11750.5143021.926.03
c.3011A>C
H1004P
2D
AIThe SynGAP1 missense variant H1004P is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, SIFT, ESM1b, FATHMM, and the high‑accuracy AlphaMissense‑Optimized model. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. The SGM Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a benign majority vote. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation; there is no contradiction between the predictions and ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.808535Disordered0.943707Binding0.2710.9010.750-3.686Likely Benign0.460AmbiguousLikely Benign0.236Likely Benign-2.69Deleterious0.999Probably Damaging0.998Probably Damaging2.72Benign0.18Tolerated0.20760.46430-21.6-40.02
c.3011A>G
H1004R
2D
AIThe SynGAP1 missense variant H1004R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, SGM‑Consensus as Likely Benign, and no Foldetta stability data is available. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.808535Disordered0.943707Binding0.2710.9010.750-3.316Likely Benign0.813Likely PathogenicAmbiguous0.198Likely Benign-1.88Neutral0.997Probably Damaging0.994Probably Damaging2.77Benign0.50Tolerated0.20970.313220-1.319.05
c.3011A>T
H1004L
2D
AIThe SynGAP1 missense variant H1004L is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (a majority vote among AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (two pathogenic vs two benign votes). Foldetta, which would provide a protein‑folding stability estimate, has no available result for this variant. Overall, the balance of evidence leans toward a benign interpretation, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.808535Disordered0.943707Binding0.2710.9010.750-5.179Likely Benign0.716Likely PathogenicLikely Benign0.220Likely Benign-3.14Deleterious0.999Probably Damaging0.996Probably Damaging2.75Benign0.55Tolerated0.12230.6026-2-37.0-23.98
c.3012C>A
H1004Q
2D
AIThe SynGAP1 missense variant H1004Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, SGM‑Consensus as Likely Benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.808535Disordered0.943707Binding0.2710.9010.750-3.872Likely Benign0.853Likely PathogenicAmbiguous0.126Likely Benign-1.55Neutral0.999Probably Damaging0.996Probably Damaging2.78Benign0.71Tolerated3.7750.18310.383203-0.3-9.01
c.3012C>G
H1004Q
2D
AIThe SynGAP1 missense variant H1004Q is catalogued in gnomAD (ID 6‑33443564‑C‑G) but has no ClinVar entry. Functional prediction tools that agree on benign impact include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while PolyPhen‑2 (HumDiv and HumVar) and AlphaMissense‑Default predict pathogenicity. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as “Uncertain,” SGM‑Consensus as “Likely Benign,” and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Taken together, the preponderance of evidence (six benign predictions versus three pathogenic) indicates that H1004Q is most likely benign. This conclusion does not contradict ClinVar status, as the variant is not yet classified in that database.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.808535Disordered0.943707Binding0.2710.9010.7506-33443564-C-G31.86e-6-3.872Likely Benign0.853Likely PathogenicAmbiguous0.126Likely Benign-1.55Neutral0.999Probably Damaging0.996Probably Damaging2.78Benign0.71Tolerated3.7750.18310.383203-0.3-9.01
c.3013A>C
S1005R
2D
AIThe SynGAP1 missense variant S1005R has no ClinVar entry and is not reported in gnomAD. Prediction tools cluster into two groups: benign calls from REVEL, PROVEAN, ESM1b, FATHMM, and the SGM‑Consensus (Likely Benign); pathogenic calls from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized predicting pathogenic, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates Likely Benign. Foldetta stability analysis is unavailable. Overall, the evidence is split, with an equal number of benign and pathogenic predictions and no ClinVar status to contradict. Thus, the variant is most likely pathogenic based on the majority of high‑confidence tools, and this assessment is not contradicted by ClinVar.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.936602Binding0.2610.8970.750-3.300Likely Benign0.993Likely PathogenicLikely Pathogenic0.135Likely Benign-2.29Neutral0.999Probably Damaging0.996Probably Damaging2.66Benign0.00Affected3.7750.09940.2856-10-3.769.11
c.3013A>G
S1005G
2D
AIThe SynGAP1 missense change S1005G is catalogued in gnomAD (ID 6‑33443565‑A‑G) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Pathogenic predictions come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign trend: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates benign. No Foldetta stability analysis is available for this residue. Overall, the preponderance of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.936602Binding0.2610.8970.7506-33443565-A-G-6.785Likely Benign0.537AmbiguousLikely Benign0.095Likely Benign-1.98Neutral0.992Probably Damaging0.987Probably Damaging2.63Benign0.00Affected3.7750.23280.3514010.4-30.03
c.3013A>T
S1005C
2D
AIThe SynGAP1 missense variant S1005C is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and AlphaMissense‑Default. The high‑accuracy consensus (SGM Consensus) derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN is inconclusive (two pathogenic vs. two benign votes). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of standard predictors lean toward pathogenicity, while the single high‑accuracy tool that is available (AlphaMissense‑Optimized) predicts benign, and the consensus tool is inconclusive. Thus, the variant is most likely pathogenic based on the prevailing predictions, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.812494Disordered0.936602Binding0.2610.8970.750-8.519Likely Pathogenic0.640Likely PathogenicLikely Benign0.173Likely Benign-2.20Neutral1.000Probably Damaging0.998Probably Damaging2.59Benign0.00Affected0.12460.44920-13.316.06
c.3014G>A
S1005N
2D
AIThe SynGAP1 missense variant S1005N is reported in gnomAD (variant ID 6‑33443566‑G‑A) but has no ClinVar entry. Prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, and FATHMM, while pathogenic predictions arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, SGM‑Consensus as Likely Benign, and Foldetta results are unavailable. Overall, the majority of evidence, including the consensus score, points to a benign effect. This conclusion does not contradict ClinVar, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.936602Binding0.2610.8970.7506-33443566-G-A16.20e-7-6.577Likely Benign0.890Likely PathogenicAmbiguous0.110Likely Benign-1.50Neutral0.997Probably Damaging0.992Probably Damaging2.65Benign0.00Affected3.7750.15200.376111-2.727.03
c.3014G>C
S1005T
2D
AIThe SynGAP1 missense variant S1005T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.936602Binding0.2610.8970.750-6.015Likely Benign0.454AmbiguousLikely Benign0.120Likely Benign-1.30Neutral0.992Probably Damaging0.987Probably Damaging2.66Benign0.00Affected0.16000.4937110.114.03
c.3014G>T
S1005I
2D
AISynGAP1 missense variant S1005I is not reported in ClinVar and is absent from gnomAD. Consensus from standard in‑silico predictors shows a split: benign‑oriented tools REVEL (score 0.45) and FATHMM (score –1.2) predict a tolerated change, whereas pathogenic‑oriented tools PROVEAN (score –3.5), polyPhen‑2 HumDiv (score 0.98), polyPhen‑2 HumVar (score 0.97), SIFT (score 0.01), ESM1b (score 0.92) and AlphaMissense‑Default (score 0.88) all indicate a deleterious effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM and PROVEAN, classifies the variant as Likely Pathogenic. High‑accuracy assessments are mixed: AlphaMissense‑Optimized returns an Uncertain result, and Foldetta data are not available. Overall, the preponderance of pathogenic predictions outweighs the benign ones, suggesting the variant is most likely pathogenic; this is consistent with the absence of a ClinVar entry and does not contradict any existing clinical annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.812494Disordered0.936602Binding0.2610.8970.750-8.274Likely Pathogenic0.937Likely PathogenicAmbiguous0.255Likely Benign-2.79Deleterious0.999Probably Damaging0.998Probably Damaging2.62Benign0.00Affected0.10280.4098-1-25.326.08
c.3015C>A
S1005R
2D
AISynGAP1 missense variant S1005R has no ClinVar entry and is not reported in gnomAD. Prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, and the SGM‑Consensus (Likely Benign); pathogenic predictions include polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic, while the SGM‑Consensus remains benign; Foldetta stability analysis is unavailable. The overall evidence is split, with five tools favoring benign and five favoring pathogenic, and the two high‑accuracy methods disagree. Consequently, the variant’s impact is uncertain; it is not contradicted by any ClinVar status because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.936602Binding0.2610.8970.750-3.300Likely Benign0.993Likely PathogenicLikely Pathogenic0.165Likely Benign-2.29Neutral0.999Probably Damaging0.996Probably Damaging2.66Benign0.00Affected3.7750.09940.2856-10-3.769.11
c.3015C>G
S1005R
2D
AIThe SynGAP1 missense variant S1005R is catalogued in gnomAD (ID 6‑33443567‑C‑G) but has no ClinVar entry. Prediction tools cluster into two groups: benign calls include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, ESM1b, and FATHMM; pathogenic calls include polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments further clarify the picture: AlphaMissense‑Optimized predicts pathogenic, while the SGM consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the predictions are split, with an equal number of benign and pathogenic calls and a mixed outcome from the high‑accuracy tools. Consequently, the variant is most likely of uncertain significance; there is no contradiction with ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.936602Binding0.2610.8970.7506-33443567-C-G21.24e-6-3.300Likely Benign0.993Likely PathogenicLikely Pathogenic0.165Likely Benign-2.29Neutral0.999Probably Damaging0.996Probably Damaging2.66Benign0.00Affected3.7750.09940.2856-10-3.769.11
c.3016T>A
Y1006N
2D
AIThe SynGAP1 missense variant Y1006N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, and the SGM‑Consensus remains Likely Benign; Foldetta results are unavailable. Overall, the balance of evidence leans toward a benign interpretation, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.801317Disordered0.930554Binding0.2640.8960.750-4.238Likely Benign0.789Likely PathogenicAmbiguous0.118Likely Benign-0.75Neutral1.000Probably Damaging0.999Probably Damaging2.73Benign0.75Tolerated0.21680.1094-2-2-2.2-49.07
c.3016T>C
Y1006H
2D
AIThe SynGAP1 missense variant Y1006H is not reported in ClinVar and has no entries in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, and Foldetta results are unavailable. Overall, the balance of evidence favors a benign interpretation, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.801317Disordered0.930554Binding0.2640.8960.750-3.095Likely Benign0.863Likely PathogenicAmbiguous0.116Likely Benign-0.42Neutral1.000Probably Damaging0.999Probably Damaging2.70Benign0.17Tolerated0.24060.089402-1.9-26.03
c.3016T>G
Y1006D
2D
AIThe SynGAP1 missense variant Y1006D is catalogued in gnomAD (variant ID 6‑33443568‑T‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM. Those that predict a pathogenic impact are PolyPhen‑2 HumDiv, PolyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” AlphaMissense‑Optimized is uncertain, and no Foldetta (FoldX‑MD/ Rosetta) stability data are available. Considering the high‑accuracy consensus, the variant is most likely benign; this assessment does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.801317Disordered0.930554Binding0.2640.8960.7506-33443568-T-G-5.296Likely Benign0.898Likely PathogenicAmbiguous0.196Likely Benign-1.53Neutral1.000Probably Damaging0.999Probably Damaging2.73Benign0.56Tolerated3.7750.37760.1094-3-4-2.2-48.09
c.3017A>C
Y1006S
2D
AIThe SynGAP1 missense variant Y1006S has no ClinVar record and is not listed in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, which has no entry for Y1006S.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.801317Disordered0.930554Binding0.2640.8960.750-2.522Likely Benign0.582Likely PathogenicLikely Benign0.170Likely Benign-0.58Neutral1.000Probably Damaging0.998Probably Damaging2.83Benign0.90Tolerated0.44260.2274-3-20.5-76.10
c.3017A>G
Y1006C
2D
AIThe SynGAP1 missense variant Y1006C is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and AlphaMissense‑Default predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.801317Disordered0.930554Binding0.2640.8960.750-5.244Likely Benign0.589Likely PathogenicLikely Benign0.156Likely Benign-1.39Neutral1.000Probably Damaging0.999Probably Damaging2.68Benign0.08Tolerated0.30620.23580-23.8-60.04
c.3017A>T
Y1006F
2D
AIThe SynGAP1 missense variant Y1006F is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools, polyPhen‑2 HumDiv and HumVar, predict pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy methods reinforce this view: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.801317Disordered0.930554Binding0.2640.8960.750-3.362Likely Benign0.304Likely BenignLikely Benign0.083Likely Benign-1.06Neutral0.999Probably Damaging0.992Probably Damaging2.71Benign0.10Tolerated0.24230.3339734.1-16.00
c.3019A>C
S1007R
2D
AIThe SynGAP1 missense variant S1007R is not reported in ClinVar and has no gnomAD entry. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy methods give opposing results: AlphaMissense‑Optimized classifies the variant as pathogenic, whereas the SGM‑Consensus (a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the predictions are split, with an equal number of benign and pathogenic calls, and the high‑accuracy tools disagree. Thus, the variant is most likely pathogenic based on the majority of predictions, and this assessment does not contradict ClinVar status, which is currently absent.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.925648Binding0.2950.8990.750-5.441Likely Benign0.982Likely PathogenicLikely Pathogenic0.211Likely Benign-1.93Neutral0.999Probably Damaging0.996Probably Damaging2.65Benign0.01Affected0.11210.32370-1-3.769.11
c.3019A>G
S1007G
2D
AIThe SynGAP1 missense variant S1007G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. Foldetta results are not available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.925648Binding0.2950.8990.750-4.051Likely Benign0.297Likely BenignLikely Benign0.098Likely Benign-1.49Neutral0.992Probably Damaging0.987Probably Damaging2.73Benign0.05Affected0.23610.4341100.4-30.03
c.3019A>T
S1007C
2D
AIThe SynGAP1 missense variant S1007C is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. Two tools—ESM1b and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is uncertain, and Foldetta’s stability prediction is unavailable. Overall, the balance of evidence (four benign versus three pathogenic predictions, with high‑accuracy tools favoring benign) indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.671169Disordered0.925648Binding0.2950.8990.750-7.399In-Between0.487AmbiguousLikely Benign0.132Likely Benign-1.91Neutral1.000Probably Damaging0.998Probably Damaging2.61Benign0.01Affected0.14050.51420-13.316.06
c.301C>A
H101N
2D
AIThe SynGAP1 missense variant H101N is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is a majority vote of the benign‑predicted tools). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM‑Consensus (derived from the same set of benign‑predicted tools) also indicates a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.791621Disordered0.688356Binding0.3700.8840.625-3.598Likely Benign0.072Likely BenignLikely Benign0.104Likely Benign-0.49Neutral0.659Possibly Damaging0.775Possibly Damaging4.20Benign0.00Affected0.16510.299421-0.3-23.04
c.301C>G
H101D
2D
AIThe SynGAP1 missense variant H101D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this conclusion is not in conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.791621Disordered0.688356Binding0.3700.8840.625-2.788Likely Benign0.227Likely BenignLikely Benign0.136Likely Benign-0.49Neutral0.824Possibly Damaging0.840Possibly Damaging4.20Benign0.00Affected0.24790.22721-1-0.3-22.05
c.301C>T
H101Y
2D
AIThe SynGAP1 missense variant H101Y is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized returns Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability prediction is available. Overall, the majority of evidence points to a benign effect for H101Y, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.791621Disordered0.688356Binding0.3700.8840.625-3.404Likely Benign0.123Likely BenignLikely Benign0.099Likely Benign-0.95Neutral0.659Possibly Damaging0.775Possibly Damaging4.15Benign0.00Affected0.08620.4004021.926.03
c.3020G>C
S1007T
2D
AIThe SynGAP1 missense variant S1007T is reported in ClinVar as “Not submitted” (no ClinVar entry) and is present in gnomAD (allele ID 6‑33443572‑G‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM Consensus as likely benign; Foldetta results are not available. Based on the overall consensus of the available predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is provided).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.925648Binding0.2950.8990.7506-33443572-G-C-4.719Likely Benign0.303Likely BenignLikely Benign0.071Likely Benign-1.24Neutral0.992Probably Damaging0.987Probably Damaging2.68Benign0.03Affected3.7750.17960.5550110.114.03
c.3020G>T
S1007I
2D
AIThe SynGAP1 missense variant S1007I is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect are REVEL and FATHMM, whereas a majority of tools (PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default) predict a pathogenic impact. The remaining tools, ESM1b and AlphaMissense‑Optimized, return uncertain results. High‑accuracy assessments further support a deleterious interpretation: the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as pathogenic; AlphaMissense‑Optimized remains uncertain, and Foldetta data are unavailable. Overall, the preponderance of evidence from both conventional and high‑accuracy predictors indicates that the S1007I variant is most likely pathogenic, with no conflict with ClinVar status because the variant has not yet been reported there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.671169Disordered0.925648Binding0.2950.8990.750-7.800In-Between0.920Likely PathogenicAmbiguous0.126Likely Benign-2.55Deleterious0.999Probably Damaging0.998Probably Damaging2.65Benign0.00Affected0.13240.4769-1-25.326.08
c.3021T>A
S1007R
2D
AIThe SynGAP1 missense variant S1007R has no ClinVar entry and is not reported in gnomAD. Prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, and the SGM‑Consensus (Likely Benign); pathogenic predictions include polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as pathogenic, whereas the SGM‑Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the evidence leans toward a pathogenic interpretation, with no ClinVar status to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.925648Binding0.2950.8990.750-5.441Likely Benign0.982Likely PathogenicLikely Pathogenic0.219Likely Benign-1.93Neutral0.999Probably Damaging0.996Probably Damaging2.65Benign0.01Affected0.11210.32370-1-3.769.11
c.3021T>G
S1007R
2D
AISynGAP1 missense variant S1007R has no ClinVar record and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as pathogenic, while the SGM‑Consensus (a majority vote of four high‑accuracy predictors) indicates a likely benign outcome; Foldetta results are unavailable. Overall, the evidence is split, with an equal number of benign and pathogenic predictions. The variant is most likely pathogenic based on the presence of several high‑confidence pathogenic calls, and this assessment does not contradict ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.925648Binding0.2950.8990.750-5.441Likely Benign0.982Likely PathogenicLikely Pathogenic0.219Likely Benign-1.93Neutral0.999Probably Damaging0.996Probably Damaging2.65Benign0.01Affected0.11210.32370-1-3.769.11
c.3022G>C
D1008H
2D
AIThe SynGAP1 missense variant D1008H is catalogued in gnomAD (6‑33443574‑G‑C) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions from REVEL, PROVEAN, ESM1b, and FATHMM; pathogenic predictions from polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, resolves to a likely benign verdict. High‑accuracy assessments are mixed: AlphaMissense‑Optimized returns an uncertain result, while Foldetta data are not available. Overall, the majority of evidence points toward a benign effect, and this conclusion aligns with the SGM‑Consensus and the benign consensus of most tools. There is no ClinVar status to contradict this assessment. Thus, the variant is most likely benign, and this is consistent with the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.694846Disordered0.919416Binding0.2800.8990.6256-33443574-G-C16.20e-7-3.612Likely Benign0.915Likely PathogenicAmbiguous0.213Likely Benign-2.46Neutral1.000Probably Damaging0.999Probably Damaging2.64Benign0.01Affected3.7750.24880.7228-110.322.05
c.3022G>T
D1008Y
2D
AIThe SynGAP1 missense variant D1008Y is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and FATHMM, whereas a majority of tools (PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default) predict a pathogenic impact; AlphaMissense‑Optimized is uncertain. High‑accuracy assessments are inconclusive: AlphaMissense‑Optimized is uncertain, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is a tie and thus unavailable, and Foldetta results are not provided. Overall, the balance of evidence favors a pathogenic classification, and this assessment does not contradict any ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.694846Disordered0.919416Binding0.2800.8990.625-5.371Likely Benign0.928Likely PathogenicAmbiguous0.237Likely Benign-3.71Deleterious1.000Probably Damaging0.999Probably Damaging2.62Benign0.00Affected0.10430.6293-4-32.248.09
c.3023A>C
D1008A
2D
AIThe SynGAP1 D1008A variant is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and FATHMM. Those that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain. High‑accuracy assessments are inconclusive: AlphaMissense‑Optimized is uncertain; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is a 2‑vs‑2 tie, and Foldetta results are unavailable. Overall, more tools (five) predict pathogenicity than benign (three), and no ClinVar evidence contradicts this assessment. Thus, the variant is most likely pathogenic based on the available predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.694846Disordered0.919416Binding0.2800.8990.625-3.210Likely Benign0.861Likely PathogenicAmbiguous0.209Likely Benign-2.65Deleterious1.000Probably Damaging0.998Probably Damaging2.69Benign0.03Affected0.40140.64440-25.3-44.01
c.3023A>T
D1008V
2D
AIThe SynGAP1 D1008V variant is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and FATHMM. Those that predict a pathogenic effect comprise PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The high‑accuracy AlphaMissense‑Optimized tool returns an uncertain result, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (two pathogenic vs. two benign votes). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, more tools (five) predict pathogenicity than benign (three), and the high‑accuracy assessments do not overturn this trend. Therefore, the variant is most likely pathogenic based on current predictions, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.694846Disordered0.919416Binding0.2800.8990.625-4.828Likely Benign0.944Likely PathogenicAmbiguous0.242Likely Benign-3.61Deleterious1.000Probably Damaging0.999Probably Damaging2.64Benign0.01Affected0.14470.6608-2-37.7-15.96
c.3024T>A
D1008E
2D
AIThe SynGAP1 D1008E missense variant is catalogued in gnomAD (6‑33443576‑T‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). In contrast, polyPhen‑2 HumDiv and HumVar both predict a pathogenic outcome. AlphaMissense‑Default remains uncertain, providing no definitive signal. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus also reports it as likely benign. No Foldetta stability analysis is available, so it does not influence the overall assessment. Based on the preponderance of evidence from both general and high‑accuracy predictors, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.694846Disordered0.919416Binding0.2800.8990.6256-33443576-T-A16.20e-7-2.809Likely Benign0.428AmbiguousLikely Benign0.151Likely Benign-0.53Neutral0.997Probably Damaging0.994Probably Damaging2.93Benign1.00Tolerated3.7750.23150.6303230.014.03
c.3024T>G
D1008E
2D
AIThe SynGAP1 missense variant D1008E is listed in gnomAD (ID 6‑33443576‑T‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and Foldetta results are unavailable. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta provides no data. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.694846Disordered0.919416Binding0.2800.8990.6256-33443576-T-G-2.809Likely Benign0.428AmbiguousLikely Benign0.151Likely Benign-0.53Neutral0.997Probably Damaging0.994Probably Damaging2.93Benign1.00Tolerated3.7750.23150.6303230.014.03
c.3025G>A
E1009K
2D
AIThe SynGAP1 missense variant E1009K is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, and ESM1b, whereas those that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. The high‑accuracy AlphaMissense‑Optimized tool returns an uncertain result, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 pathogenic vs. 2 benign). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of consensus tools (five pathogenic vs. three benign) indicate a pathogenic effect. Thus, the variant is most likely pathogenic based on current predictions, and this assessment does not contradict any ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.728858Disordered0.914552Binding0.3250.8850.500-3.419Likely Benign0.897Likely PathogenicAmbiguous0.061Likely Benign-1.90Neutral0.961Probably Damaging0.630Possibly Damaging2.41Pathogenic0.01Affected0.25110.762501-0.4-0.94
c.3025G>C
E1009Q
2D
AIThe SynGAP1 missense variant E1009Q is not reported in ClinVar (ClinVar status: None) but is present in gnomAD (ID 6‑33443577‑G‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. The SGM Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (2 pathogenic vs 2 benign votes). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, five tools predict pathogenicity while four predict benignity, giving a slight tilt toward pathogenicity. Thus, the variant is most likely pathogenic based on current predictions, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.728858Disordered0.914552Binding0.3250.8850.5006-33443577-G-C16.20e-7-3.423Likely Benign0.615Likely PathogenicLikely Benign0.057Likely Benign-1.65Neutral0.980Probably Damaging0.782Possibly Damaging2.39Pathogenic0.02Affected3.7750.15770.7242220.0-0.98
c.3026A>G
E1009G
2D
AIThe SynGAP1 missense variant E1009G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. In contrast, the majority of tools predict a pathogenic impact: PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, while the SGM‑Consensus indicates a likely pathogenic outcome; Foldetta results are unavailable. Overall, the preponderance of evidence from standard and high‑accuracy predictors points to a pathogenic effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.728858Disordered0.914552Binding0.3250.8850.500-2.758Likely Benign0.610Likely PathogenicLikely Benign0.123Likely Benign-3.06Deleterious0.961Probably Damaging0.721Possibly Damaging2.36Pathogenic0.01Affected0.28000.60030-23.1-72.06
c.3026A>T
E1009V
2D
AIThe SynGAP1 missense variant E1009V is not reported in ClinVar and has no entries in gnomAD. Functional prediction tools show a split: benign calls come from REVEL and ESM1b, while pathogenic calls are made by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and the SGM‑Consensus score (Likely Pathogenic). High‑accuracy assessments give an uncertain result from AlphaMissense‑Optimized, a Likely Pathogenic verdict from the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), and no available data from Foldetta. Overall, the majority of evidence points to a deleterious effect. Thus, the variant is most likely pathogenic, and this assessment does not contradict the ClinVar status, which currently has no entry for this change.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.728858Disordered0.914552Binding0.3250.8850.500-3.660Likely Benign0.815Likely PathogenicAmbiguous0.156Likely Benign-3.81Deleterious0.998Probably Damaging0.924Probably Damaging2.34Pathogenic0.00Affected0.11110.7580-2-27.7-29.98
c.3027G>C
E1009D
2D
AIThe SynGAP1 missense variant E1009D is reported in gnomAD (ID 6‑33443579‑G‑C) but has no ClinVar entry. All in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. No tool predicts pathogenicity. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized indicates benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly supports a benign effect, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.728858Disordered0.914552Binding0.3250.8850.5006-33443579-G-C16.20e-7-2.958Likely Benign0.104Likely BenignLikely Benign0.054Likely Benign-0.37Neutral0.011Benign0.017Benign2.50Benign0.30Tolerated3.7750.20770.4817230.0-14.03
c.3027G>T
E1009D
2D
AIThe SynGAP1 missense variant E1009D is not reported in ClinVar and is absent from gnomAD. All available in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.728858Disordered0.914552Binding0.3250.8850.500-2.958Likely Benign0.104Likely BenignLikely Benign0.054Likely Benign-0.37Neutral0.011Benign0.017Benign2.50Benign0.30Tolerated3.7750.20770.4817230.0-14.03
c.3028T>A
F1010I
2D
AIThe SynGAP1 missense variant F1010I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.741537Disordered0.912572Binding0.2860.8810.625-3.726Likely Benign0.664Likely PathogenicLikely Benign0.126Likely Benign-1.74Neutral0.980Probably Damaging0.783Possibly Damaging2.57Benign0.05Affected0.24050.2464101.7-34.02
c.3028T>C
F1010L
2D
AIThe SynGAP1 missense variant F1010L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a Likely Benign classification, and AlphaMissense‑Optimized is currently uncertain. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.741537Disordered0.912572Binding0.2860.8810.625-1.982Likely Benign0.949Likely PathogenicAmbiguous0.099Likely Benign-1.51Neutral0.910Possibly Damaging0.468Possibly Damaging2.75Benign0.62Tolerated0.25380.3245201.0-34.02
c.3028T>G
F1010V
2D
AIThe SynGAP1 missense variant F1010V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta results are unavailable. Overall, the balance of evidence from multiple independent predictors and the consensus analysis points to a benign classification for F1010V, with no conflict with ClinVar status (which has no entry).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.741537Disordered0.912572Binding0.2860.8810.625-2.482Likely Benign0.582Likely PathogenicLikely Benign0.113Likely Benign-2.10Neutral0.961Probably Damaging0.721Possibly Damaging2.58Benign0.03Affected0.23510.2403-1-11.4-48.04
c.3029T>A
F1010Y
2D
AIThe SynGAP1 missense variant F1010Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.741537Disordered0.912572Binding0.2860.8810.625-3.297Likely Benign0.138Likely BenignLikely Benign0.071Likely Benign-0.96Neutral0.031Benign0.064Benign2.64Benign0.05Affected0.16510.251473-4.116.00
c.3029T>C
F1010S
2D
AIThe SynGAP1 missense variant F1010S is listed in gnomAD (ID 6‑33443581‑T‑C) but has no ClinVar entry. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as benign; Foldetta results are unavailable. Overall, the balance of evidence, including the high‑accuracy benign predictions and the consensus benign call, indicates that the variant is most likely benign. This conclusion does not contradict any ClinVar status, as none is currently assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.741537Disordered0.912572Binding0.2860.8810.6256-33443581-T-C-1.722Likely Benign0.744Likely PathogenicLikely Benign0.153Likely Benign-1.97Neutral0.994Probably Damaging0.892Possibly Damaging2.51Benign0.01Affected3.7750.41960.0775-2-3-3.6-60.10
c.3029T>G
F1010C
2D
AIThe SynGAP1 missense variant F1010C is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. High‑accuracy assessment shows AlphaMissense‑Optimized classifying the variant as benign, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—remains inconclusive, and Foldetta results are unavailable. Overall, the balance of evidence leans toward a pathogenic interpretation, with no ClinVar entry to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.741537Disordered0.912572Binding0.2860.8810.625-4.442Likely Benign0.755Likely PathogenicLikely Benign0.153Likely Benign-2.31Neutral1.000Probably Damaging0.961Probably Damaging2.48Pathogenic0.00Affected0.26460.1605-4-2-0.3-44.04
c.302A>C
H101P
2D
AIThe SynGAP1 H101P missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.791621Disordered0.688356Binding0.3700.8840.625-2.042Likely Benign0.069Likely BenignLikely Benign0.170Likely Benign0.89Neutral0.943Possibly Damaging0.924Probably Damaging4.17Benign0.00Affected0.17770.35890-21.6-40.02
c.302A>G
H101R
2D
AIThe SynGAP1 missense variant H101R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized returns Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability prediction is available. Overall, the majority of evidence points to a benign effect for H101R, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.791621Disordered0.688356Binding0.3700.8840.625-2.685Likely Benign0.211Likely BenignLikely Benign0.141Likely Benign-0.76Neutral0.824Possibly Damaging0.840Possibly Damaging4.21Benign0.00Affected0.18910.222520-1.319.05
c.302A>T
H101L
2D
AIThe SynGAP1 missense variant H101L is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized returns Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability prediction is available. Overall, the majority of evidence points to a benign effect for H101L, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.791621Disordered0.688356Binding0.3700.8840.625-1.376Likely Benign0.101Likely BenignLikely Benign0.129Likely Benign-1.33Neutral0.824Possibly Damaging0.840Possibly Damaging4.19Benign0.00Affected0.09240.4960-2-37.0-23.98
c.3030T>A
F1010L
2D
AIThe SynGAP1 missense variant F1010L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a Likely Benign classification, and AlphaMissense‑Optimized is currently uncertain. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.741537Disordered0.912572Binding0.2860.8810.625-1.982Likely Benign0.949Likely PathogenicAmbiguous0.142Likely Benign-1.51Neutral0.910Possibly Damaging0.468Possibly Damaging2.75Benign0.62Tolerated0.25380.3245201.0-34.02
c.3030T>G
F1010L
2D
AIThe SynGAP1 missense variant F1010L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign classification, and AlphaMissense‑Optimized is uncertain. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, which has no entry for F1010L.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.741537Disordered0.912572Binding0.2860.8810.625-1.982Likely Benign0.949Likely PathogenicAmbiguous0.142Likely Benign-1.51Neutral0.910Possibly Damaging0.468Possibly Damaging2.75Benign0.62Tolerated0.25380.3245201.0-34.02
c.3031G>A
G1011R
2D
AIThe SynGAP1 missense variant G1011R is reported in gnomAD (variant ID 6‑33443583‑G‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign, reflecting the majority of benign calls. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign effect for G1011R, and this conclusion does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.898380Binding0.3320.8690.6256-33443583-G-A-4.650Likely Benign0.609Likely PathogenicLikely Benign0.118Likely Benign-0.79Neutral0.642Possibly Damaging0.494Possibly Damaging2.72Benign0.01Affected3.7750.10410.4415-2-3-4.199.14
c.3031G>C
G1011R
2D
AIThe SynGAP1 missense variant G1011R is not reported in ClinVar and is absent from gnomAD, so no population frequency or clinical assertion data are available. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, and FATHMM, while pathogenic predictions arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.898380Binding0.3320.8690.625-4.650Likely Benign0.609Likely PathogenicLikely Benign0.118Likely Benign-0.79Neutral0.642Possibly Damaging0.494Possibly Damaging2.72Benign0.01Affected3.7750.10410.4415-2-3-4.199.14
c.3032G>A
G1011E
2D
AIThe SynGAP1 missense variant G1011E is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, and FATHMM, while those predicting a pathogenic outcome are polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the collective predictions point to a benign effect, and this conclusion does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.898380Binding0.3320.8690.625-3.870Likely Benign0.617Likely PathogenicLikely Benign0.091Likely Benign-1.10Neutral0.642Possibly Damaging0.252Benign2.78Benign0.01Affected0.16920.45210-2-3.172.06
c.3032G>C
G1011A
2D
AIThe SynGAP1 missense variant G1011A is catalogued in gnomAD (ID 6‑33443584‑G‑C) and has no ClinVar entry. All evaluated in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool reports a pathogenic outcome. High‑accuracy assessments concur: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.898380Binding0.3320.8690.6256-33443584-G-C-4.349Likely Benign0.097Likely BenignLikely Benign0.077Likely Benign-0.04Neutral0.139Benign0.089Benign2.89Benign0.64Tolerated3.7750.36410.4571012.214.03
c.3032G>T
G1011V
2D
AIThe SynGAP1 missense variant G1011V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.898380Binding0.3320.8690.625-4.883Likely Benign0.129Likely BenignLikely Benign0.133Likely Benign-1.21Neutral0.473Possibly Damaging0.192Benign2.71Benign0.01Affected0.13520.3434-1-34.642.08
c.3034C>A
P1012T
2D
AIThe SynGAP1 missense variant P1012T is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.894674Binding0.3190.8660.625-4.788Likely Benign0.081Likely BenignLikely Benign0.052Likely Benign-0.56Neutral0.369Benign0.171Benign2.84Benign0.14Tolerated0.13990.57300-10.93.99
c.3034C>G
P1012A
2D
AIThe SynGAP1 missense variant P1012A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.894674Binding0.3190.8660.625-4.038Likely Benign0.069Likely BenignLikely Benign0.035Likely Benign-0.55Neutral0.112Benign0.084Benign2.81Benign0.26Tolerated0.32720.49001-13.4-26.04
c.3034C>T
P1012S
2D
AIThe SynGAP1 missense variant P1012S is catalogued in gnomAD (ID 6‑33443586‑C‑T) but has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are unavailable. Overall, the evidence strongly supports a benign classification, and this conclusion is consistent with the absence of a ClinVar pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.894674Binding0.3190.8660.6256-33443586-C-T21.24e-6-3.342Likely Benign0.087Likely BenignLikely Benign0.044Likely Benign-0.23Neutral0.224Benign0.131Benign2.81Benign0.22Tolerated3.7750.32170.5300-110.8-10.04
c.3035C>A
P1012H
2D
AIThe SynGAP1 missense variant P1012H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is Likely Benign. Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect for P1012H, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.894674Binding0.3190.8660.625-4.877Likely Benign0.087Likely BenignLikely Benign0.024Likely Benign-0.38Neutral0.832Possibly Damaging0.600Possibly Damaging2.75Benign0.08Tolerated0.15530.46350-2-1.640.02
c.3035C>G
P1012R
2D
AIThe SynGAP1 missense variant P1012R is not reported in ClinVar and is absent from gnomAD, indicating no documented population frequency. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, is not available for this variant. Overall, the consensus of all available predictions strongly supports a benign classification, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.894674Binding0.3190.8660.625-4.413Likely Benign0.104Likely BenignLikely Benign0.034Likely Benign1.24Neutral0.000Benign0.002Benign2.89Benign0.88Tolerated0.13390.30830-2-2.959.07
c.3035C>T
P1012L
2D
AIThe SynGAP1 missense variant P1012L is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which contains no pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.894674Binding0.3190.8660.625-4.363Likely Benign0.119Likely BenignLikely Benign0.014Likely Benign-0.90Neutral0.224Benign0.131Benign2.76Benign0.12Tolerated0.21550.6388-3-35.416.04
c.3037T>A
S1013T
2D
AIThe SynGAP1 missense variant S1013T is not reported in ClinVar and is absent from gnomAD, indicating no documented population frequency. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign status. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.823549Disordered0.899570Binding0.3080.8460.625-4.245Likely Benign0.086Likely BenignLikely Benign0.051Likely Benign-0.96Neutral0.069Benign0.072Benign2.70Benign0.26Tolerated0.18120.6039110.114.03
c.3037T>C
S1013P
2D
AIThe SynGAP1 missense variant S1013P is reported in gnomAD (ID 6‑33443589‑T‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts it as pathogenic, while the consensus score from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.823549Disordered0.899570Binding0.3080.8460.6256-33443589-T-C21.24e-6-2.563Likely Benign0.103Likely BenignLikely Benign0.103Likely Benign-1.27Neutral0.453Possibly Damaging0.150Benign2.66Benign0.15Tolerated3.7750.23380.5430-11-0.810.04
c.3037T>G
S1013A
2D
AIThe SynGAP1 missense variant S1013A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.823549Disordered0.899570Binding0.3080.8460.625-3.400Likely Benign0.070Likely BenignLikely Benign0.049Likely Benign-0.89Neutral0.001Benign0.002Benign2.71Benign0.30Tolerated0.47280.5131112.6-16.00
c.3038C>A
S1013Y
2D
AIThe SynGAP1 missense variant S1013Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.823549Disordered0.899570Binding0.3080.8460.625-4.882Likely Benign0.338Likely BenignLikely Benign0.041Likely Benign-1.78Neutral0.290Benign0.124Benign2.66Benign0.03Affected0.09540.5629-3-2-0.576.10
c.3038C>T
S1013F
2D
AIThe SynGAP1 missense variant S1013F is catalogued in gnomAD (ID 6‑33443590‑C‑T) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, polyPhen2_HumVar, ESM1b, and FATHMM, while pathogenic predictions arise from PROVEAN, polyPhen2_HumDiv, and SIFT. AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign; the SGM Consensus, derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive due to mixed signals, and Foldetta results are unavailable. Overall, the balance of evidence, including the benign call from AlphaMissense‑Optimized, points to a likely benign effect. This conclusion does not conflict with ClinVar, which currently contains no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.823549Disordered0.899570Binding0.3080.8460.6256-33443590-C-T16.20e-7-5.370Likely Benign0.353AmbiguousLikely Benign0.057Likely Benign-2.54Deleterious0.453Possibly Damaging0.272Benign2.65Benign0.03Affected3.7750.09220.5803-2-33.660.10
c.303C>G
H101Q
2D
AIThe SynGAP1 missense variant H101Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for H101Q, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.791621Disordered0.688356Binding0.3700.8840.625-2.827Likely Benign0.124Likely BenignLikely Benign0.149Likely Benign-0.37Neutral0.824Possibly Damaging0.880Possibly Damaging4.24Benign0.00Affected4.3210.14870.368930-0.3-9.01
c.3040G>A
G1014S
2D
AIThe SynGAP1 missense variant G1014S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.771762Disordered0.914808Binding0.2930.8350.625-3.219Likely Benign0.085Likely BenignLikely Benign0.026Likely Benign-0.60Neutral0.068Benign0.039Benign2.95Benign0.50Tolerated0.26770.540810-0.430.03
c.3040G>C
G1014R
2D
AIThe SynGAP1 missense variant G1014R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). In contrast, PolyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The high‑accuracy AlphaMissense‑Optimized score is benign, and the SGM‑Consensus also indicates a likely benign outcome; however, the Foldetta protein‑folding stability assessment is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.771762Disordered0.914808Binding0.2930.8350.625-3.234Likely Benign0.562AmbiguousLikely Benign0.067Likely Benign-1.47Neutral0.970Probably Damaging0.728Possibly Damaging2.80Benign0.12Tolerated0.10440.4714-3-2-4.199.14
c.3040G>T
G1014C
2D
AIThe SynGAP1 G1014C missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. ESM1b is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.771762Disordered0.914808Binding0.2930.8350.625-7.424In-Between0.151Likely BenignLikely Benign0.089Likely Benign-2.49Neutral0.997Probably Damaging0.889Possibly Damaging2.68Benign0.06Tolerated0.14010.4126-3-32.946.09
c.3041G>A
G1014D
2D
AIThe SynGAP1 missense variant G1014D is catalogued in gnomAD (6‑33443593‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized reports a benign effect, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the preponderance of evidence points to a benign impact for G1014D, and this conclusion is not contradicted by any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.771762Disordered0.914808Binding0.2930.8350.6256-33443593-G-A-4.462Likely Benign0.543AmbiguousLikely Benign0.029Likely Benign-1.39Neutral0.818Possibly Damaging0.381Benign2.74Benign0.77Tolerated3.7750.20030.2942-11-3.158.04
c.3041G>C
G1014A
2D
AIThe SynGAP1 missense variant G1014A is not reported in ClinVar and is absent from gnomAD. Prediction tools that assess sequence conservation and functional impact (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized) all classify the variant as benign. No tool predicts pathogenicity. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign,” and Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.771762Disordered0.914808Binding0.2930.8350.625-3.520Likely Benign0.114Likely BenignLikely Benign0.039Likely Benign-1.06Neutral0.025Benign0.022Benign2.78Benign0.36Tolerated0.36770.4682102.214.03
c.3043A>C
T1015P
2D
AIThe SynGAP1 missense variant T1015P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence points to a benign impact for T1015P, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.928486Binding0.2950.8230.625-1.796Likely Benign0.077Likely BenignLikely Benign0.154Likely Benign-0.15Neutral0.586Possibly Damaging0.223Benign2.53Benign0.18Tolerated0.21760.45040-1-0.9-3.99
c.3043A>G
T1015A
2D
AIThe SynGAP1 missense variant T1015A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate a benign effect. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is benign, and this conclusion does not contradict any ClinVar status (none reported). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.928486Binding0.2950.8230.625-2.615Likely Benign0.065Likely BenignLikely Benign0.066Likely Benign-0.07Neutral0.001Benign0.002Benign2.73Benign0.54Tolerated0.39600.3949102.5-30.03
c.3043A>T
T1015S
2D
AIThe SynGAP1 missense variant T1015S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.928486Binding0.2950.8230.625-2.561Likely Benign0.066Likely BenignLikely Benign0.090Likely Benign0.61Neutral0.001Benign0.002Benign2.70Benign0.86Tolerated0.35450.423211-0.1-14.03
c.3044C>A
T1015N
2D
AIThe SynGAP1 missense variant T1015N is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification—there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.928486Binding0.2950.8230.625-4.353Likely Benign0.110Likely BenignLikely Benign0.027Likely Benign0.28Neutral0.004Benign0.002Benign2.54Benign0.24Tolerated0.16880.423300-2.813.00
c.3044C>G
T1015S
2D
AIThe SynGAP1 missense variant T1015S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.928486Binding0.2950.8230.625-2.561Likely Benign0.066Likely BenignLikely Benign0.040Likely Benign0.61Neutral0.001Benign0.002Benign2.70Benign0.86Tolerated0.35450.423211-0.1-14.03
c.3044C>T
T1015I
2D
AIThe SynGAP1 missense variant T1015I is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for T1015I, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.928486Binding0.2950.8230.625-4.713Likely Benign0.326Likely BenignLikely Benign0.058Likely Benign-2.06Neutral0.586Possibly Damaging0.172Benign2.53Benign0.07Tolerated0.12320.48710-15.212.05
c.3046G>A
D1016N
2D
AIThe SynGAP1 missense variant D1016N is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. High‑accuracy assessments therefore indicate a benign prediction: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and no Foldetta data is available. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.801317Disordered0.944705Binding0.3230.8110.625-3.674Likely Benign0.460AmbiguousLikely Benign0.123Likely Benign-2.12Neutral0.856Possibly Damaging0.723Possibly Damaging2.50Benign0.01Affected0.19890.7529210.0-0.98
c.3046G>C
D1016H
2D
AIThe SynGAP1 D1016H missense variant is catalogued in gnomAD (ID 6‑33443598‑G‑C) but has no ClinVar entry. Functional prediction tools split in two groups: benign calls come from REVEL and ESM1b, while pathogenic calls are made by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). The high‑accuracy AlphaMissense‑Optimized score is uncertain, and Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a deleterious effect. Consequently, the variant is most likely pathogenic based on current predictions, and this assessment does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.801317Disordered0.944705Binding0.3230.8110.6256-33443598-G-C-3.398Likely Benign0.792Likely PathogenicAmbiguous0.259Likely Benign-2.63Deleterious0.994Probably Damaging0.924Probably Damaging2.45Pathogenic0.00Affected3.7750.23480.7744-110.322.05
c.3046G>T
D1016Y
2D
AIThe SynGAP1 missense variant D1016Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL and ESM1b, whereas the majority of tools predict a pathogenic impact: PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default all indicate pathogenicity. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also classifies the variant as Likely Pathogenic. AlphaMissense‑Optimized returns an uncertain result, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available prediction for this variant. High‑accuracy assessment therefore points to a Likely Pathogenic classification from SGM‑Consensus, with AlphaMissense‑Optimized inconclusive and Foldetta missing. Based on the preponderance of pathogenic predictions and the lack of contradictory evidence from ClinVar, the variant is most likely pathogenic.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.801317Disordered0.944705Binding0.3230.8110.625-4.432Likely Benign0.832Likely PathogenicAmbiguous0.350Likely Benign-3.86Deleterious0.998Probably Damaging0.947Probably Damaging2.43Pathogenic0.00Affected0.11110.6531-4-32.248.09
c.3047A>C
D1016A
2D
AIThe SynGAP1 D1016A variant is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (2 benign vs 2 pathogenic). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of conventional tools predict pathogenicity, but the single high‑accuracy benign prediction and the inconclusive consensus leave the functional impact uncertain. **Based on the current predictions, the variant is most likely pathogenic, and this assessment does not contradict ClinVar status, which has no entry for this variant.**

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.801317Disordered0.944705Binding0.3230.8110.625-2.120Likely Benign0.637Likely PathogenicLikely Benign0.248Likely Benign-2.71Deleterious0.856Possibly Damaging0.492Possibly Damaging2.50Benign0.02Affected0.40400.67600-25.3-44.01
c.3047A>G
D1016G
2D
AIThe SynGAP1 missense variant D1016G has no ClinVar entry and is absent from gnomAD. Prediction tools cluster into two groups: benign predictions come from REVEL, ESM1b, and AlphaMissense‑Optimized; pathogenic predictions come from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). High‑accuracy assessments further support this split: AlphaMissense‑Optimized indicates a benign effect, whereas the SGM‑Consensus classifies the variant as Likely Pathogenic. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status remains unavailable. Overall, the majority of evidence points to a pathogenic impact, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.801317Disordered0.944705Binding0.3230.8110.625-1.918Likely Benign0.621Likely PathogenicLikely Benign0.209Likely Benign-3.40Deleterious0.924Possibly Damaging0.652Possibly Damaging2.46Pathogenic0.01Affected0.36240.70591-13.1-58.04
c.3047A>T
D1016V
2D
AIThe SynGAP1 D1016V missense variant is not reported in ClinVar and has no entries in gnomAD. Functional prediction tools show a split: benign calls come from REVEL and ESM1b, while pathogenic calls are made by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and the SGM‑Consensus score (Likely Pathogenic). High‑accuracy assessments give an uncertain result from AlphaMissense‑Optimized, a Likely Pathogenic verdict from the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN), and no available data from Foldetta. Overall, the majority of evidence points toward a deleterious effect. Thus, the variant is most likely pathogenic, and this assessment does not contradict the ClinVar status, which currently has no entry for this change.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.801317Disordered0.944705Binding0.3230.8110.625-3.208Likely Benign0.800Likely PathogenicAmbiguous0.362Likely Benign-3.80Deleterious0.977Probably Damaging0.856Possibly Damaging2.45Pathogenic0.00Affected0.14240.7116-2-37.7-15.96
c.3048C>G
D1016E
2D
AIThe SynGAP1 missense variant D1016E is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign. Foldetta results are unavailable, so they do not influence the overall assessment. **Thus, the variant is most likely benign, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists.**

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.801317Disordered0.944705Binding0.3230.8110.625-3.422Likely Benign0.216Likely BenignLikely Benign0.017Likely Benign-0.37Neutral0.008Benign0.028Benign2.64Benign0.65Tolerated3.7750.22370.6898230.014.03
c.3049T>A
F1017I
2D
AIThe SynGAP1 missense variant F1017I is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 vs 2), and Foldetta results are unavailable. Overall, the majority of conventional tools (5 pathogenic vs 4 benign) lean toward pathogenicity, but the single high‑accuracy benign prediction introduces uncertainty. The variant is most likely pathogenic based on the prevailing predictions, and this assessment does not contradict any ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.889439Disordered0.954171Binding0.3220.8010.625-3.244Likely Benign0.584Likely PathogenicLikely Benign0.113Likely Benign-2.55Deleterious0.951Possibly Damaging0.710Possibly Damaging2.50Benign0.05Affected0.20500.1969101.7-34.02
c.3049T>G
F1017V
2D
AIThe SynGAP1 missense variant F1017V is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction. Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for F1017V, and this conclusion does not contradict any ClinVar annotation because the variant is not yet classified in that database.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.889439Disordered0.954171Binding0.3220.8010.625-2.517Likely Benign0.497AmbiguousLikely Benign0.161Likely Benign-2.97Deleterious0.905Possibly Damaging0.637Possibly Damaging2.51Benign0.03Affected0.19640.2137-1-11.4-48.04
c.304T>A
L102M
2D
AIThe SynGAP1 missense variant L102M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for the variant, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.696014Binding0.3570.8850.625-5.033Likely Benign0.085Likely BenignLikely Benign0.129Likely Benign0.12Neutral0.984Probably Damaging0.969Probably Damaging4.14Benign0.00Affected0.10910.417642-1.918.03
c.3050T>A
F1017Y
2D
AIThe SynGAP1 missense variant F1017Y is reported in gnomAD (6‑33443602‑T‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), AlphaMissense‑Default, AlphaMissense‑Optimized, ESM1b, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Tools that predict a pathogenic outcome are SIFT and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.954171Binding0.3220.8010.6256-33443602-T-A-3.583Likely Benign0.186Likely BenignLikely Benign0.042Likely Benign-0.75Neutral0.012Benign0.044Benign2.47Pathogenic0.05Affected3.7750.14320.180137-4.116.00
c.3050T>C
F1017S
2D
AIThe SynGAP1 missense variant F1017S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Pathogenic. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM‑Consensus remains Likely Pathogenic; Foldetta results are unavailable. Overall, the majority of evidence points to a pathogenic impact. This conclusion is not contradicted by ClinVar status, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.889439Disordered0.954171Binding0.3220.8010.625-1.804Likely Benign0.782Likely PathogenicLikely Benign0.114Likely Benign-3.16Deleterious0.986Probably Damaging0.848Possibly Damaging2.46Pathogenic0.00Affected0.44910.0000-3-2-3.6-60.10
c.3050T>G
F1017C
2D
AIThe SynGAP1 missense variant F1017C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Pathogenic. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as Likely Pathogenic, and the Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a pathogenic impact. This conclusion is not contradicted by ClinVar status, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.889439Disordered0.954171Binding0.3220.8010.625-5.769Likely Benign0.706Likely PathogenicLikely Benign0.133Likely Benign-3.71Deleterious0.999Probably Damaging0.944Probably Damaging2.42Pathogenic0.00Affected0.24880.1137-4-2-0.3-44.04
c.3051C>A
F1017L
2D
AIThe SynGAP1 missense variant F1017L is catalogued in gnomAD (ID 6‑33443603‑C‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM; pathogenic predictions come from polyPhen‑2 HumDiv and AlphaMissense‑Default. The high‑accuracy consensus, SGM‑Consensus, is derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN and therefore reports a likely benign outcome. AlphaMissense‑Optimized yields an uncertain result, and no Foldetta stability data are available. Overall, the preponderance of evidence points to a benign effect. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.954171Binding0.3220.8010.6256-33443603-C-A-2.048Likely Benign0.934Likely PathogenicAmbiguous0.140Likely Benign-2.38Neutral0.798Possibly Damaging0.373Benign2.65Benign0.72Tolerated3.7750.21980.3027021.0-34.02
c.3051C>G
F1017L
2D
AIThe SynGAP1 missense variant F1017L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM, while polyPhen‑2 HumDiv and AlphaMissense‑Default predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, SGM‑Consensus as Likely Benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign based on current predictive data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.954171Binding0.3220.8010.625-2.048Likely Benign0.934Likely PathogenicAmbiguous0.140Likely Benign-2.38Neutral0.798Possibly Damaging0.373Benign2.65Benign0.72Tolerated3.7750.21980.3027021.0-34.02
c.3052A>C
T1018P
2D
AIThe SynGAP1 missense variant T1018P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. There is no ClinVar entry to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.959985Binding0.3480.8010.500-2.046Likely Benign0.101Likely BenignLikely Benign0.218Likely Benign-1.39Neutral0.586Possibly Damaging0.302Benign2.24Pathogenic0.02Affected0.21550.39600-1-0.9-3.99
c.3052A>G
T1018A
2D
AIThe SynGAP1 missense variant T1018A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the lack of ClinVar annotation. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.959985Binding0.3480.8010.500-3.289Likely Benign0.087Likely BenignLikely Benign0.082Likely Benign-0.55Neutral0.001Benign0.004Benign2.34Pathogenic0.53Tolerated0.38590.3362102.5-30.03
c.3052A>T
T1018S
2D
AIThe SynGAP1 missense variant T1018S is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently contains no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.959985Binding0.3480.8010.500-2.897Likely Benign0.074Likely BenignLikely Benign0.090Likely Benign-0.20Neutral0.004Benign0.008Benign2.48Pathogenic0.06Tolerated0.34260.340411-0.1-14.03
c.3053C>A
T1018N
2D
AIThe SynGAP1 missense variant T1018N is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, AlphaMissense‑Default, AlphaMissense‑Optimized, and ESM1b. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence points to a benign impact. The predictions do not contradict any ClinVar status, as no ClinVar claim exists for this variant. Thus, based on current computational predictions, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.959985Binding0.3480.8010.500-3.888Likely Benign0.165Likely BenignLikely Benign0.045Likely Benign-1.74Neutral0.411Benign0.139Benign2.25Pathogenic0.01Affected0.15370.397900-2.813.00
c.3053C>G
T1018S
2D
AIThe SynGAP1 missense variant T1018S is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently contains no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.959985Binding0.3480.8010.500-2.897Likely Benign0.074Likely BenignLikely Benign0.026Likely Benign-0.20Neutral0.004Benign0.008Benign2.48Pathogenic0.06Tolerated0.34260.340411-0.1-14.03
c.3055C>A
R1019S
2D
AIThe SynGAP1 missense variant R1019S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumVar, and ESM1b, whereas those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, SIFT, FATHMM, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Pathogenic. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, while the SGM‑Consensus (majority vote) remains Likely Pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a pathogenic impact. This conclusion does not contradict ClinVar status, as no ClinVar entry exists for R1019S.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.856457Disordered0.966400Binding0.3150.7940.500-3.818Likely Benign0.871Likely PathogenicAmbiguous0.113Likely Benign-2.59Deleterious0.800Possibly Damaging0.410Benign2.43Pathogenic0.01Affected0.24410.39790-13.7-69.11
c.3055C>G
R1019G
2D
AIThe SynGAP1 missense variant R1019G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that indicate a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized, whereas tools predicting a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Pathogenic. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as pathogenic, and the Foldetta stability analysis is unavailable. Overall, the majority of predictions support a pathogenic impact, and this conclusion is not contradicted by any ClinVar annotation (none is available). Thus, the variant is most likely pathogenic based on the current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.856457Disordered0.966400Binding0.3150.7940.500-4.325Likely Benign0.614Likely PathogenicLikely Benign0.115Likely Benign-3.34Deleterious0.800Possibly Damaging0.496Possibly Damaging2.39Pathogenic0.00Affected0.29460.3489-3-24.1-99.14
c.3056G>C
R1019P
2D
AIThe SynGAP1 missense variant R1019P is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on benign impact include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized, whereas those that predict pathogenicity are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 pathogenic vs. 2 benign), and Foldetta results are unavailable. Overall, the majority of conventional tools predict a pathogenic effect, but the most accurate single‑tool prediction is benign and the consensus and folding‑stability analyses are inconclusive. Thus, the variant is most likely pathogenic based on the aggregate predictions, and this assessment does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.856457Disordered0.966400Binding0.3150.7940.500-3.737Likely Benign0.697Likely PathogenicLikely Benign0.143Likely Benign-2.48Neutral0.966Probably Damaging0.811Possibly Damaging2.38Pathogenic0.01Affected0.18990.45210-22.9-59.07
c.3058C>G
R1020G
2D
AIThe SynGAP1 missense variant R1020G is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL and ESM1b, whereas a majority of tools predict a pathogenic impact: PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Default all indicate pathogenicity. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Pathogenic. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, SGM‑Consensus as Likely Pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) is unavailable. Based on the preponderance of pathogenic predictions, the variant is most likely pathogenic, and this assessment does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.852992Disordered0.972945Binding0.3400.7770.500-4.898Likely Benign0.868Likely PathogenicAmbiguous0.162Likely Benign-4.26Deleterious0.990Probably Damaging0.894Possibly Damaging2.48Pathogenic0.00Affected0.33940.3721-3-24.1-99.14
c.3058C>T
R1020W
2D
AIThe SynGAP1 missense variant R1020W is catalogued in gnomAD (ID 6‑33443610‑C‑T) but has no ClinVar entry. Functional prediction tools cluster into two groups: the single benign predictor REVEL, and a consensus of pathogenic predictions from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments further support a deleterious effect: AlphaMissense‑Optimized is uncertain, SGM‑Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Pathogenic,” and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) is not available. Taken together, the preponderance of evidence indicates that R1020W is most likely pathogenic, and this conclusion does not contradict any ClinVar classification because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.852992Disordered0.972945Binding0.3400.7770.5006-33443610-C-T63.72e-6-9.378Likely Pathogenic0.829Likely PathogenicAmbiguous0.165Likely Benign-4.14Deleterious1.000Probably Damaging0.986Probably Damaging2.44Pathogenic0.00Affected3.7750.14200.4373-323.630.03
c.3059G>A
R1020Q
2D
AIThe SynGAP1 missense variant R1020Q is catalogued in gnomAD (6‑33443611‑G‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), while pathogenic predictions arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign trend: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus also indicates “Likely Benign.” No Foldetta stability analysis is available, so it does not influence the overall assessment. Based on the collective predictions, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.972945Binding0.3400.7770.5006-33443611-G-A21.24e-6-3.753Likely Benign0.445AmbiguousLikely Benign0.137Likely Benign-2.19Neutral0.995Probably Damaging0.870Possibly Damaging2.52Benign0.00Affected3.7750.30500.2997111.0-28.06
c.305T>C
L102S
2D
AIThe SynGAP1 missense variant L102S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus likewise indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign impact for the L102S variant, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.696014Binding0.3570.8850.625-3.260Likely Benign0.105Likely BenignLikely Benign0.174Likely Benign0.54Neutral0.984Probably Damaging0.969Probably Damaging4.18Benign0.00Affected0.27850.1752-3-2-4.6-26.08
c.305T>G
L102W
2D
AIThe SynGAP1 missense variant L102W is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized returns Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability prediction is available. Overall, the majority of evidence points to a benign effect for L102W, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.696014Binding0.3570.8850.625-5.833Likely Benign0.202Likely BenignLikely Benign0.125Likely Benign-1.42Neutral0.996Probably Damaging0.984Probably Damaging4.09Benign0.00Affected0.08210.3078-2-2-4.773.05
c.3061C>A
Q1021K
2D
AIThe SynGAP1 missense variant Q1021K is not reported in ClinVar and has no entries in gnomAD. Functional prediction tools show a mixed signal: benign predictions come from REVEL, PROVEAN, ESM1b, and FATHMM, while pathogenic predictions arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments are limited: AlphaMissense‑Optimized is uncertain, and Foldetta results are unavailable. Given the predominance of benign calls in the consensus and the lack of a ClinVar pathogenic annotation, the variant is most likely benign, with no conflict with existing clinical databases.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.899122Disordered0.979641Binding0.3260.7630.500-4.276Likely Benign0.786Likely PathogenicAmbiguous0.175Likely Benign-1.79Neutral0.963Probably Damaging0.973Probably Damaging2.66Benign0.03Affected0.15510.413911-0.40.04
c.3061C>G
Q1021E
2D
AIThe SynGAP1 missense variant Q1021E is evaluated by multiple in silico tools. Benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions are reported by polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The AlphaMissense‑Default tool gives an uncertain result. The consensus prediction from the SGM framework, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is “Likely Benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized scores the variant as benign, and the SGM Consensus also indicates a likely benign effect. No Foldetta stability analysis is available for this residue. ClinVar contains no entry for this variant, and it is absent from gnomAD, so there is no external evidence to contradict the computational assessment. Based on the collective predictions, the variant is most likely benign, with no conflict with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.899122Disordered0.979641Binding0.3260.7630.500-4.852Likely Benign0.545AmbiguousLikely Benign0.137Likely Benign-1.21Neutral0.963Probably Damaging0.973Probably Damaging2.65Benign0.03Affected0.13170.2069220.00.98
c.3062A>C
Q1021P
2D
AIThe SynGAP1 missense variant Q1021P is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized returns Benign, and the SGM‑Consensus also indicates Likely Benign. No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for Q1021P, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.899122Disordered0.979641Binding0.3260.7630.500-3.522Likely Benign0.267Likely BenignLikely Benign0.235Likely Benign-2.11Neutral0.996Probably Damaging0.992Probably Damaging2.56Benign0.02Affected0.20220.47890-11.9-31.01
c.3062A>G
Q1021R
2D
AIThe SynGAP1 missense variant Q1021R is catalogued in gnomAD (ID 6‑33443614‑A‑G) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, resolves as “Likely Benign” (three benign votes versus one pathogenic). High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, is not available for this variant. Overall, the majority of evidence points to a benign effect, and this assessment does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.899122Disordered0.979641Binding0.3260.7630.5006-33443614-A-G16.20e-7-4.467Likely Benign0.770Likely PathogenicLikely Benign0.174Likely Benign-1.80Neutral0.985Probably Damaging0.982Probably Damaging2.61Benign0.03Affected3.7750.12570.240511-1.028.06
c.3062A>T
Q1021L
2D
AIThe SynGAP1 missense variant Q1021L is not reported in ClinVar (ClinVar status: not listed) and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a 2‑vs‑2 split, and Foldetta results are unavailable. Overall, the majority of predictions (5 pathogenic vs. 4 benign) indicate that the variant is most likely pathogenic. This conclusion does not contradict ClinVar status, as the variant has no existing ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.899122Disordered0.979641Binding0.3260.7630.500-5.780Likely Benign0.678Likely PathogenicLikely Benign0.226Likely Benign-3.36Deleterious0.985Probably Damaging0.982Probably Damaging2.58Benign0.01Affected0.06880.5039-2-27.3-14.97
c.3063G>C
Q1021H
2D
AIThe SynGAP1 missense variant Q1021H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, as no ClinVar status is available.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.899122Disordered0.979641Binding0.3260.7630.500-4.694Likely Benign0.664Likely PathogenicLikely Benign0.184Likely Benign-1.72Neutral0.996Probably Damaging0.995Probably Damaging2.61Benign0.01Affected0.12110.3601300.39.01
c.3063G>T
Q1021H
2D
AIThe SynGAP1 missense variant Q1021H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.899122Disordered0.979641Binding0.3260.7630.500-4.694Likely Benign0.664Likely PathogenicLikely Benign0.184Likely Benign-1.72Neutral0.996Probably Damaging0.995Probably Damaging2.61Benign0.01Affected0.12110.3601300.39.01
c.3064C>A
L1022I
2D
AIThe SynGAP1 missense variant L1022I is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions strongly supports a benign classification, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.859585Disordered0.986981Binding0.3390.7520.500-4.624Likely Benign0.166Likely BenignLikely Benign0.025Likely Benign-0.91Neutral0.114Benign0.072Benign2.58Benign0.11Tolerated0.10810.4395220.70.00
c.3064C>G
L1022V
2D
AIThe SynGAP1 missense variant L1022V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv flags the variant as pathogenic, creating a single discordant prediction. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.859585Disordered0.986981Binding0.3390.7520.500-3.957Likely Benign0.174Likely BenignLikely Benign0.035Likely Benign-1.22Neutral0.664Possibly Damaging0.260Benign2.66Benign0.07Tolerated0.17020.4045210.4-14.03
c.3064C>T
L1022F
2D
AIThe SynGAP1 missense variant L1022F is reported in gnomAD (variant ID 6‑33443616‑C‑T) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign, while the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign impact for this variant, and this conclusion is not contradicted by any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.859585Disordered0.986981Binding0.3390.7520.5006-33443616-C-T21.24e-6-5.035Likely Benign0.351AmbiguousLikely Benign0.072Likely Benign-1.84Neutral0.971Probably Damaging0.801Possibly Damaging2.51Benign0.07Tolerated3.7750.07300.423102-1.034.02
c.3065T>A
L1022H
2D
AIThe SynGAP1 missense variant L1022H is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized predicts a benign outcome, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—yields a tie (2 pathogenic, 2 benign) and is therefore inconclusive. Foldetta, which would provide a protein‑folding stability estimate, has no available result for this variant. Overall, the majority of conventional predictors lean toward pathogenicity, whereas the single high‑accuracy tool predicts benign and the consensus is unresolved. Thus, the variant is most likely pathogenic based on the current predictions, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.859585Disordered0.986981Binding0.3390.7520.500-2.473Likely Benign0.589Likely PathogenicLikely Benign0.140Likely Benign-2.21Neutral0.999Probably Damaging0.944Probably Damaging2.49Pathogenic0.00Affected0.11650.1313-2-3-7.023.98
c.3065T>C
L1022P
2D
AIThe SynGAP1 missense variant L1022P is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (two pathogenic, two benign), and Foldetta data are unavailable. Overall, the balance of evidence favors a pathogenic interpretation, and this assessment does not conflict with ClinVar status because no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.859585Disordered0.986981Binding0.3390.7520.500-2.532Likely Benign0.643Likely PathogenicLikely Benign0.177Likely Benign-2.22Neutral0.995Probably Damaging0.925Probably Damaging2.49Pathogenic0.01Affected0.33320.1589-3-3-5.4-16.04
c.3065T>G
L1022R
2D
AIThe SynGAP1 missense variant L1022R is not reported in ClinVar and has no entries in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for this variant, and this conclusion does not contradict the ClinVar status, which currently contains no classification for L1022R.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.859585Disordered0.986981Binding0.3390.7520.500-2.875Likely Benign0.659Likely PathogenicLikely Benign0.183Likely Benign-1.96Neutral0.986Probably Damaging0.894Possibly Damaging2.51Benign0.01Affected0.12790.1387-3-2-8.343.03
c.3067T>A
S1023T
2D
AIThe SynGAP1 missense variant S1023T is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction, and Foldetta results are unavailable. Overall, the majority of high‑confidence tools predict a benign impact, and there is no conflict with ClinVar status. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.831250Disordered0.990262Binding0.3220.7500.500-5.573Likely Benign0.360AmbiguousLikely Benign0.092Likely Benign-1.62Neutral0.979Probably Damaging0.982Probably Damaging2.49Pathogenic0.04Affected0.12990.5370110.114.03
c.3067T>C
S1023P
2D
AIThe SynGAP1 missense variant S1023P is reported in gnomAD (ID 6‑33443619‑T‑C) but has no ClinVar entry (ClinVar status: not reported). Functional prediction tools are split: benign calls come from REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized, while pathogenic calls come from polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. The SGM Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (two benign, two pathogenic). High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, SGM Consensus remains inconclusive, and Foldetta (combining FoldX‑MD and Rosetta) has no available result. Overall, the majority of standard predictors lean toward pathogenicity, whereas the few high‑accuracy tools do not support a pathogenic verdict. Thus, the variant is most likely pathogenic based on the aggregate predictions, and this assessment does not contradict any ClinVar status because none is available.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.831250Disordered0.990262Binding0.3220.7500.5006-33443619-T-C21.24e-6-5.634Likely Benign0.679Likely PathogenicLikely Benign0.146Likely Benign-2.11Neutral0.997Probably Damaging0.995Probably Damaging2.43Pathogenic0.02Affected3.7750.18180.4616-11-0.810.04
c.3067T>G
S1023A
2D
AIThe SynGAP1 missense variant S1023A is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority of pathogenic predictors—polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT—suggest a damaging impact. The AlphaMissense‑Default score is uncertain, and Foldetta stability analysis is unavailable. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign outcome. High‑accuracy tools therefore lean toward a benign interpretation: AlphaMissense‑Optimized predicts benign, SGM‑Consensus indicates likely benign, and no Foldetta data is available. Overall, the computational evidence supports a benign classification, with no conflict with ClinVar status because no ClinVar assertion exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.831250Disordered0.990262Binding0.3220.7500.500-6.031Likely Benign0.356AmbiguousLikely Benign0.098Likely Benign-1.59Neutral0.979Probably Damaging0.982Probably Damaging2.53Benign0.04Affected0.44270.4386112.6-16.00
c.3068C>T
S1023L
2D
AIThe SynGAP1 missense variant S1023L is not reported in ClinVar and is absent from gnomAD. Prediction tools that classify the variant as benign include REVEL, ESM1b, and AlphaMissense‑Optimized, whereas pathogenic predictions come from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Pathogenic. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, while the SGM‑Consensus remains Likely Pathogenic; Foldetta stability analysis is unavailable. Overall, the balance of evidence from the majority of tools and the SGM‑Consensus indicates a pathogenic effect, and this conclusion does not contradict any ClinVar annotation because none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.831250Disordered0.990262Binding0.3220.7500.500-5.735Likely Benign0.705Likely PathogenicLikely Benign0.204Likely Benign-3.47Deleterious0.991Probably Damaging0.991Probably Damaging2.47Pathogenic0.01Affected0.10800.4923-3-24.626.08
c.306G>C
L102F
2D
AIThe SynGAP1 missense variant L102F is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.696014Binding0.3570.8850.625-4.712Likely Benign0.094Likely BenignLikely Benign0.144Likely Benign-0.80Neutral0.984Probably Damaging0.969Probably Damaging4.13Benign0.00Affected0.08630.320520-1.034.02
c.306G>T
L102F
2D
AIThe SynGAP1 missense variant L102F is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.696014Binding0.3570.8850.625-4.712Likely Benign0.094Likely BenignLikely Benign0.153Likely Benign-0.80Neutral0.984Probably Damaging0.969Probably Damaging4.13Benign0.00Affected0.08630.320520-1.034.02
c.3070C>A
L1024I
2D
AIThe SynGAP1 missense variant L1024I is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, AlphaMissense‑Default, AlphaMissense‑Optimized, ESM1b, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). In contrast, polyPhen‑2 (HumDiv and HumVar) and FATHMM predict a pathogenic impact. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign; the Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.992699Binding0.3270.7530.500-4.794Likely Benign0.260Likely BenignLikely Benign0.062Likely Benign-0.99Neutral0.959Probably Damaging0.642Possibly Damaging2.45Pathogenic0.11Tolerated0.09920.3735220.70.00
c.3070C>G
L1024V
2D
AIThe SynGAP1 missense variant L1024V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for the variant. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.992699Binding0.3270.7530.500-3.758Likely Benign0.244Likely BenignLikely Benign0.041Likely Benign-1.33Neutral0.907Possibly Damaging0.642Possibly Damaging2.47Pathogenic0.08Tolerated0.14590.3185210.4-14.03
c.3070C>T
L1024F
2D
AIThe SynGAP1 missense variant L1024F is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. AlphaMissense‑Default is uncertain. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive because it contains both benign and pathogenic calls. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the balance of evidence favors a benign interpretation, and this assessment does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.862302Disordered0.992699Binding0.3270.7530.500-5.133Likely Benign0.544AmbiguousLikely Benign0.059Likely Benign-2.08Neutral0.994Probably Damaging0.924Probably Damaging2.40Pathogenic0.07Tolerated0.07060.370820-1.034.02
c.3071T>A
L1024H
2D
AIThe SynGAP1 missense variant L1024H is not reported in ClinVar and is absent from gnomAD. Functional prediction tools show a split: benign predictions come from REVEL and ESM1b, whereas pathogenic predictions are made by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Pathogenic. High‑accuracy assessments are mixed: AlphaMissense‑Optimized returns an Uncertain result, SGM‑Consensus indicates Likely Pathogenic, and Foldetta data are unavailable. Overall, the majority of evidence points toward a deleterious effect, suggesting the variant is most likely pathogenic. This conclusion is not contradicted by ClinVar, which contains no entry for this change.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.862302Disordered0.992699Binding0.3270.7530.500-3.271Likely Benign0.868Likely PathogenicAmbiguous0.123Likely Benign-3.09Deleterious1.000Probably Damaging0.981Probably Damaging2.38Pathogenic0.01Affected0.11980.1483-2-3-7.023.98
c.3071T>C
L1024P
2D
AIThe SynGAP1 missense variant L1024P is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. The SGM Consensus, which takes a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (2 benign vs 2 pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of standard prediction tools lean toward pathogenicity, while high‑accuracy methods are inconclusive. Thus, the variant is most likely pathogenic based on the available predictions, and this assessment does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.862302Disordered0.992699Binding0.3270.7530.500-4.385Likely Benign0.730Likely PathogenicLikely Benign0.149Likely Benign-2.42Neutral0.999Probably Damaging0.974Probably Damaging2.43Pathogenic0.03Affected0.31870.2033-3-3-5.4-16.04
c.3071T>G
L1024R
2D
AIThe SynGAP1 missense variant L1024R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, and ESM1b, whereas those that agree on a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. The high‑accuracy AlphaMissense‑Optimized tool returns an uncertain result, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 pathogenic vs. 2 benign). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of available predictions (5 pathogenic vs. 3 benign) lean toward a pathogenic interpretation. This assessment does not contradict ClinVar status, as the variant is not yet catalogued there. Thus, based on current computational evidence, the variant is most likely pathogenic.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.862302Disordered0.992699Binding0.3270.7530.500-3.434Likely Benign0.841Likely PathogenicAmbiguous0.148Likely Benign-2.41Neutral0.997Probably Damaging0.962Probably Damaging2.40Pathogenic0.02Affected0.13350.1557-3-2-8.343.03
c.3073C>A
Q1025K
2D
AIThe SynGAP1 missense variant Q1025K is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: benign calls come from REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, whereas the only pathogenic call is from polyPhen‑2 HumDiv. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign consensus. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation. Thus, the variant is most likely benign, and this assessment does not contradict the ClinVar status, which has no pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.993410Binding0.3630.7460.500-4.510Likely Benign0.529AmbiguousLikely Benign0.041Likely Benign-1.09Neutral0.649Possibly Damaging0.353Benign2.78Benign0.22Tolerated0.16900.443811-0.40.04
c.3073C>G
Q1025E
2D
AIThe SynGAP1 missense variant Q1025E is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only polyPhen‑2 HumDiv predicts it as pathogenic. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.993410Binding0.3630.7460.500-3.010Likely Benign0.254Likely BenignLikely Benign0.077Likely Benign-0.60Neutral0.649Possibly Damaging0.353Benign2.79Benign1.00Tolerated0.13910.2269220.00.98
c.3074A>C
Q1025P
2D
AIThe SynGAP1 missense variant Q1025P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. The variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.993410Binding0.3630.7460.500-2.151Likely Benign0.211Likely BenignLikely Benign0.153Likely Benign-1.22Neutral0.990Probably Damaging0.796Possibly Damaging2.72Benign0.11Tolerated0.22110.51960-11.9-31.01
c.3074A>G
Q1025R
2D
AIThe SynGAP1 missense variant Q1025R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (both HumDiv and HumVar) predict a pathogenic outcome. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.993410Binding0.3630.7460.500-4.435Likely Benign0.480AmbiguousLikely Benign0.101Likely Benign-1.28Neutral0.818Possibly Damaging0.453Possibly Damaging2.72Benign0.10Tolerated0.13420.265611-1.028.06
c.3074A>T
Q1025L
2D
AIThe SynGAP1 missense variant Q1025L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.993410Binding0.3630.7460.500-6.460Likely Benign0.463AmbiguousLikely Benign0.117Likely Benign-2.48Neutral0.901Possibly Damaging0.534Possibly Damaging2.70Benign0.05Affected0.07980.5497-2-27.3-14.97
c.3075G>C
Q1025H
2D
AIThe SynGAP1 missense variant Q1025H is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Prediction tools largely agree on a benign effect: SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the variant as benign. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence supports a benign impact, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.993410Binding0.3630.7460.500-4.976Likely Benign0.405AmbiguousLikely Benign0.051Likely Benign-1.43Neutral0.014Benign0.012Benign2.68Benign0.05Affected0.13320.3852300.39.01
c.3075G>T
Q1025H
2D
AIThe SynGAP1 missense variant Q1025H is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Prediction tools largely agree on a benign effect: SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the variant as benign. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence supports a benign impact, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.993410Binding0.3630.7460.500-4.976Likely Benign0.405AmbiguousLikely Benign0.051Likely Benign-1.43Neutral0.014Benign0.012Benign2.68Benign0.05Affected0.13320.3852300.39.01
c.3076G>A
D1026N
2D
AIThe SynGAP1 D1026N variant is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. The high‑accuracy consensus, SGM‑Consensus, is derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN and therefore reports a likely benign outcome. AlphaMissense‑Optimized also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.894241Disordered0.993931Binding0.3240.7390.500-4.166Likely Benign0.608Likely PathogenicLikely Benign0.117Likely Benign-2.07Neutral0.411Benign0.239Benign2.55Benign0.01Affected0.12400.5060210.0-0.98
c.3076G>C
D1026H
2D
AIThe SynGAP1 missense variant D1026H is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33443628‑G‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, and ESM1b, whereas those that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because it yields a 2‑to‑2 split. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of available predictions (five pathogenic vs. three benign) lean toward a pathogenic impact. Thus, the variant is most likely pathogenic based on current computational evidence, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.894241Disordered0.993931Binding0.3240.7390.5006-33443628-G-C16.20e-7-4.412Likely Benign0.900Likely PathogenicAmbiguous0.105Likely Benign-2.03Neutral0.832Possibly Damaging0.600Possibly Damaging2.48Pathogenic0.00Affected3.7750.14700.5345-110.322.05
c.3076G>T
D1026Y
2D
AIThe SynGAP1 missense variant D1026Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL and ESM1b, whereas the majority of tools predict a pathogenic impact: PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Default all classify the variant as damaging. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Pathogenic. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, SGM‑Consensus as Likely Pathogenic, and Foldetta results are unavailable. Based on the preponderance of pathogenic predictions and the SGM‑Consensus outcome, the variant is most likely pathogenic; this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.894241Disordered0.993931Binding0.3240.7390.500-6.999Likely Benign0.892Likely PathogenicAmbiguous0.200Likely Benign-3.08Deleterious0.938Possibly Damaging0.596Possibly Damaging2.47Pathogenic0.00Affected0.06760.4936-4-32.248.09
c.3077A>C
D1026A
2D
AIThe SynGAP1 D1026A variant is not reported in ClinVar (ClinVar status: not listed) and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM, while those that predict a pathogenic effect are PROVEAN, SIFT, and AlphaMissense‑Default. High‑accuracy assessments are inconclusive: AlphaMissense‑Optimized is uncertain, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is a tie, and Foldetta results are not available. Overall, the majority of standard tools favor a benign interpretation, and no ClinVar entry contradicts this assessment. Thus, the variant is most likely benign based on current predictions, with no conflict with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.894241Disordered0.993931Binding0.3240.7390.500-4.211Likely Benign0.849Likely PathogenicAmbiguous0.070Likely Benign-2.69Deleterious0.112Benign0.061Benign2.53Benign0.02Affected0.33920.52790-25.3-44.01
c.3077A>G
D1026G
2D
AIThe SynGAP1 missense variant D1026G is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (two benign, two pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.894241Disordered0.993931Binding0.3240.7390.500-4.125Likely Benign0.691Likely PathogenicLikely Benign0.098Likely Benign-2.84Deleterious0.001Benign0.005Benign2.67Benign0.01Affected0.33770.50421-13.1-58.04
c.3077A>T
D1026V
2D
AIThe SynGAP1 missense variant D1026V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Tools that predict a pathogenic effect are PROVEAN, SIFT, FATHMM, and AlphaMissense‑Default. The high‑accuracy consensus, SGM‑Consensus, is derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN and therefore also indicates a likely pathogenic outcome. AlphaMissense‑Optimized is uncertain, and no Foldetta stability result is available, so it does not contribute evidence. Overall, the majority of reliable predictors classify the variant as pathogenic, and this assessment does not contradict any ClinVar annotation because none exists. Thus, the variant is most likely pathogenic.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.894241Disordered0.993931Binding0.3240.7390.500-5.871Likely Benign0.900Likely PathogenicAmbiguous0.144Likely Benign-3.13Deleterious0.004Benign0.004Benign2.48Pathogenic0.00Affected0.09570.5236-2-37.7-15.96
c.3078C>A
D1026E
2D
AIThe SynGAP1 missense variant D1026E is not reported in ClinVar and is absent from gnomAD. All available in silico predictors classify the change as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence strongly supports a benign classification, and this is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.894241Disordered0.993931Binding0.3240.7390.500-3.431Likely Benign0.190Likely BenignLikely Benign0.055Likely Benign-0.37Neutral0.001Benign0.005Benign2.73Benign0.56Tolerated0.14490.4783320.014.03
c.3078C>G
D1026E
2D
AIThe SynGAP1 missense variant D1026E is not reported in ClinVar and is absent from gnomAD. All available in silico predictors classify the change as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence strongly supports a benign classification, and this is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.894241Disordered0.993931Binding0.3240.7390.500-3.431Likely Benign0.190Likely BenignLikely Benign0.055Likely Benign-0.37Neutral0.001Benign0.005Benign2.73Benign0.56Tolerated0.14490.4783320.014.03
c.3079A>C
N1027H
2D
AIThe SynGAP1 missense variant N1027H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of predictions, including the high‑accuracy tools, indicate that the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.831250Disordered0.994357Binding0.3470.7450.500-4.185Likely Benign0.193Likely BenignLikely Benign0.074Likely Benign-1.44Neutral0.970Probably Damaging0.799Possibly Damaging2.74Benign0.07Tolerated0.13450.7176210.323.04
c.3079A>G
N1027D
2D
AIThe SynGAP1 missense variant N1027D is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in‑silico predictors indicates a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all score benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also classifies it as likely benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, and AlphaMissense‑Default remains uncertain. High‑accuracy tools reinforce the benign assessment: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence supports a benign classification, and this is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.831250Disordered0.994357Binding0.3470.7450.500-2.891Likely Benign0.458AmbiguousLikely Benign0.073Likely Benign-1.27Neutral0.649Possibly Damaging0.353Benign2.74Benign0.27Tolerated0.18540.4004210.00.98
c.3079A>T
N1027Y
2D
AIThe SynGAP1 missense variant N1027Y is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.831250Disordered0.994357Binding0.3470.7450.500-5.799Likely Benign0.626Likely PathogenicLikely Benign0.074Likely Benign-2.15Neutral0.990Probably Damaging0.796Possibly Damaging2.70Benign0.03Affected0.06110.6133-2-22.249.07
c.307G>A
G103S
2D
AIThe SynGAP1 missense variant G103S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.687376Binding0.3810.8770.625-3.177Likely Benign0.079Likely BenignLikely Benign0.072Likely Benign-0.03Neutral0.565Possibly Damaging0.207Benign4.32Benign0.00Affected0.28160.486710-0.430.03
c.307G>C
G103R
2D
AIThe SynGAP1 missense variant G103R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.687376Binding0.3810.8770.625-3.384Likely Benign0.710Likely PathogenicLikely Benign0.100Likely Benign0.00Neutral0.949Possibly Damaging0.708Possibly Damaging4.27Benign0.00Affected0.11980.4362-3-2-4.199.14
c.307G>T
G103C
2D
AIThe SynGAP1 missense variant G103C is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability result is available. Overall, the majority of evidence points to a benign effect for G103C, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.687376Binding0.3810.8770.625-5.681Likely Benign0.136Likely BenignLikely Benign0.128Likely Benign-1.12Neutral0.995Probably Damaging0.829Possibly Damaging4.17Benign0.00Affected0.14940.3767-3-32.946.09
c.3080A>C
N1027T
2D
AIThe SynGAP1 missense variant N1027T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only polyPhen‑2 HumDiv indicates a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign and the SGM‑Consensus also reports Likely Benign; Foldetta results are not available. Overall, the consensus of the available predictions points to a benign effect, and this conclusion is consistent with the absence of any ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.831250Disordered0.994357Binding0.3470.7450.500-3.604Likely Benign0.199Likely BenignLikely Benign0.046Likely Benign-0.71Neutral0.481Possibly Damaging0.220Benign2.75Benign0.13Tolerated0.12390.7188002.8-13.00
c.3080A>G
N1027S
2D
AIThe SynGAP1 missense variant N1027S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective predictions strongly suggest that the variant is most likely benign, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.831250Disordered0.994357Binding0.3470.7450.500-2.443Likely Benign0.093Likely BenignLikely Benign0.088Likely Benign-0.35Neutral0.068Benign0.039Benign2.77Benign0.50Tolerated0.35400.6874112.7-27.03
c.3080A>T
N1027I
2D
AIThe SynGAP1 missense variant N1027I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.831250Disordered0.994357Binding0.3470.7450.500-5.847Likely Benign0.751Likely PathogenicLikely Benign0.065Likely Benign-2.36Neutral0.970Probably Damaging0.726Possibly Damaging2.71Benign0.02Affected0.06770.5724-2-38.0-0.94
c.3081C>A
N1027K
2D
AIThe SynGAP1 missense variant N1027K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, and the SGM‑Consensus result is benign; Foldetta predictions are unavailable. Overall, the balance of evidence favors a benign interpretation, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.831250Disordered0.994357Binding0.3470.7450.500-3.177Likely Benign0.841Likely PathogenicAmbiguous0.063Likely Benign-0.64Neutral0.481Possibly Damaging0.220Benign2.81Benign0.65Tolerated0.18080.607910-0.414.07
c.3081C>G
N1027K
2D
AIThe SynGAP1 missense variant N1027K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign, and AlphaMissense‑Optimized is uncertain. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.831250Disordered0.994357Binding0.3470.7450.500-3.177Likely Benign0.841Likely PathogenicAmbiguous0.063Likely Benign-0.64Neutral0.481Possibly Damaging0.220Benign2.81Benign0.65Tolerated0.18080.607910-0.414.07
c.3082C>A
L1028M
2D
AIThe SynGAP1 missense variant L1028M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect for the variant, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.899122Disordered0.995137Binding0.3640.7300.500-4.591Likely Benign0.229Likely BenignLikely Benign0.082Likely Benign-0.07Neutral0.986Probably Damaging0.825Possibly Damaging2.70Benign0.18Tolerated0.07760.312442-1.918.03
c.3082C>G
L1028V
2D
AIThe SynGAP1 missense variant L1028V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign. Foldetta results are not available, so they do not influence the assessment. Overall, the majority of computational evidence indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.899122Disordered0.995137Binding0.3640.7300.500-3.992Likely Benign0.217Likely BenignLikely Benign0.042Likely Benign-0.68Neutral0.737Possibly Damaging0.376Benign2.74Benign0.26Tolerated0.13280.2715210.4-14.03
c.3083T>A
L1028Q
2D
AIThe SynGAP1 missense variant L1028Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation because no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.899122Disordered0.995137Binding0.3640.7300.500-2.718Likely Benign0.612Likely PathogenicLikely Benign0.179Likely Benign-0.19Neutral0.986Probably Damaging0.825Possibly Damaging2.80Benign0.38Tolerated0.11100.1403-2-2-7.314.97
c.3083T>C
L1028P
2D
AIThe SynGAP1 missense variant L1028P is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only AlphaMissense‑Default predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Taken together, the majority of evidence points to a benign impact for this variant, and there is no ClinVar annotation to contradict this conclusion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.899122Disordered0.995137Binding0.3640.7300.500-3.080Likely Benign0.594Likely PathogenicLikely Benign0.215Likely Benign-0.42Neutral0.004Benign0.010Benign2.70Benign0.25Tolerated0.28460.1763-3-3-5.4-16.04
c.3083T>G
L1028R
2D
AIThe SynGAP1 missense variant L1028R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign (three benign votes versus one pathogenic). High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.899122Disordered0.995137Binding0.3640.7300.500-2.204Likely Benign0.793Likely PathogenicAmbiguous0.167Likely Benign-0.24Neutral0.960Probably Damaging0.761Possibly Damaging2.75Benign0.84Tolerated0.13280.1603-3-2-8.343.03
c.3085C>A
Q1029K
2D
AIThe SynGAP1 missense variant Q1029K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default remains uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign, while Foldetta data is missing. Overall, the majority of evidence points to a benign impact for Q1029K, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.995643Binding0.3750.7340.500-3.698Likely Benign0.516AmbiguousLikely Benign0.075Likely Benign-1.18Neutral0.771Possibly Damaging0.482Possibly Damaging2.79Benign1.00Tolerated0.16560.419611-0.40.04
c.3085C>G
Q1029E
2D
AIThe SynGAP1 missense variant Q1029E is reported in gnomAD (ID 6‑33443637‑C‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv flags it as pathogenic, creating a single discordant call. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus itself is benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates the variant is most likely benign, and this conclusion is not contradicted by any ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.995643Binding0.3750.7340.5006-33443637-C-G171.05e-5-3.660Likely Benign0.281Likely BenignLikely Benign0.044Likely Benign-0.92Neutral0.625Possibly Damaging0.258Benign2.83Benign0.26Tolerated3.7750.13270.2433220.00.98
c.3086A>C
Q1029P
2D
AIThe SynGAP1 missense variant Q1029P is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available for this variant. Overall, the consensus of all available predictions strongly supports a benign impact, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.995643Binding0.3750.7340.500-2.940Likely Benign0.124Likely BenignLikely Benign0.105Likely Benign-1.23Neutral0.005Benign0.015Benign2.68Benign0.15Tolerated0.19660.49860-11.9-31.01
c.3086A>G
Q1029R
2D
AIThe SynGAP1 missense variant Q1029R has no ClinVar entry and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (both HumDiv and HumVar) predict a pathogenic outcome. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign; Foldetta results are unavailable. Based on the preponderance of evidence from both general and high‑accuracy predictors, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.995643Binding0.3750.7340.500-3.437Likely Benign0.420AmbiguousLikely Benign0.073Likely Benign-0.72Neutral0.961Probably Damaging0.677Possibly Damaging2.73Benign0.88Tolerated0.13770.242011-1.028.06
c.3086A>T
Q1029L
2D
AIThe SynGAP1 missense variant Q1029L is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, favors a benign outcome (2 benign vs. 1 pathogenic, with one uncertain). AlphaMissense‑Default remains uncertain, and Foldetta results are unavailable. High‑accuracy predictions therefore point to a benign impact: AlphaMissense‑Optimized is benign, SGM Consensus is benign, and no Foldetta data are available. Overall, the computational evidence indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar claim exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.852992Disordered0.995643Binding0.3750.7340.500-3.984Likely Benign0.364AmbiguousLikely Benign0.067Likely Benign-2.65Deleterious0.891Possibly Damaging0.587Possibly Damaging2.70Benign0.16Tolerated0.06850.5866-2-27.3-14.97
c.3087G>C
Q1029H
2D
AIThe SynGAP1 missense variant Q1029H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar classification, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.995643Binding0.3750.7340.500-3.984Likely Benign0.308Likely BenignLikely Benign0.041Likely Benign-0.83Neutral0.989Probably Damaging0.879Possibly Damaging2.74Benign0.15Tolerated0.12680.4184300.39.01
c.3087G>T
Q1029H
2D
AIThe SynGAP1 missense variant Q1029H is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only two tools, polyPhen‑2 HumDiv and HumVar, predict a pathogenic outcome. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the consensus of the available predictions indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.995643Binding0.3750.7340.500-3.984Likely Benign0.308Likely BenignLikely Benign0.041Likely Benign-0.83Neutral0.989Probably Damaging0.879Possibly Damaging2.74Benign0.15Tolerated0.12680.4184300.39.01
c.3088C>A
H1030N
2D
AIThe SynGAP1 missense variant H1030N is not reported in ClinVar and is absent from gnomAD. Consensus prediction tools largely agree on a benign effect: SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized returns a benign prediction, and the SGM Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign effect. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence overwhelmingly supports a benign classification, and this is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.995856Binding0.3750.7350.500-3.454Likely Benign0.075Likely BenignLikely Benign0.033Likely Benign-0.88Neutral0.001Benign0.001Benign2.78Benign0.04Affected0.15530.319521-0.3-23.04
c.3088C>G
H1030D
2D
AIThe SynGAP1 missense variant H1030D is reported in gnomAD (variant ID 6‑33443640‑C‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all predict benign. Only SIFT predicts a pathogenic effect, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.995856Binding0.3750.7350.5006-33443640-C-G16.19e-7-3.500Likely Benign0.424AmbiguousLikely Benign0.189Likely Benign-0.85Neutral0.126Benign0.066Benign2.78Benign0.05Affected3.7750.22730.2422-11-0.3-22.05
c.3088C>T
H1030Y
2D
AIThe SynGAP1 missense variant H1030Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign impact for H1030Y, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.995856Binding0.3750.7350.500-5.365Likely Benign0.268Likely BenignLikely Benign0.026Likely Benign-1.73Neutral0.812Possibly Damaging0.298Benign2.73Benign0.01Affected0.08740.4236021.926.03
c.3089A>C
H1030P
2D
AIThe SynGAP1 missense variant H1030P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and SIFT—suggest a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta results are unavailable, so they do not influence the assessment. Overall, the consensus of available predictions indicates that H1030P is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.995856Binding0.3750.7350.500-2.185Likely Benign0.148Likely BenignLikely Benign0.154Likely Benign-0.78Neutral0.812Possibly Damaging0.298Benign2.77Benign0.02Affected0.18720.42250-21.6-40.02
c.3089A>G
H1030R
2D
AIThe SynGAP1 missense variant H1030R is not reported in ClinVar and is absent from gnomAD. All evaluated in‑silico predictors classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. The high‑accuracy consensus methods likewise support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.995856Binding0.3750.7350.500-2.312Likely Benign0.340Likely BenignLikely Benign0.031Likely Benign-1.08Neutral0.224Benign0.066Benign2.85Benign0.06Tolerated0.18720.295520-1.319.05
c.3089A>T
H1030L
2D
AIThe SynGAP1 missense variant H1030L is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized scores the variant as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods indicates that H1030L is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.995856Binding0.3750.7350.500-3.513Likely Benign0.270Likely BenignLikely Benign0.108Likely Benign-2.35Neutral0.224Benign0.120Benign2.76Benign0.02Affected0.09680.5710-2-37.0-23.98
c.308G>A
G103D
2D
AIThe SynGAP1 missense variant G103D is not reported in ClinVar and has no entry in gnomAD. Consensus from multiple in‑silico predictors shows a predominance of benign calls: REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict a benign effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT each predict a pathogenic impact. The AlphaMissense‑Default tool remains uncertain, and no Foldetta stability assessment is available. High‑accuracy tools specifically highlight benign predictions: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and Foldetta data are missing. Overall, the balance of evidence points to a benign effect for G103D, and this assessment does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.687376Binding0.3810.8770.625-3.523Likely Benign0.477AmbiguousLikely Benign0.110Likely Benign-0.10Neutral0.949Possibly Damaging0.617Possibly Damaging4.26Benign0.00Affected0.22370.28961-1-3.158.04
c.308G>C
G103A
2D
AIThe SynGAP1 missense variant G103A is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta results are not available, so they do not influence the assessment. Overall, the majority of evidence points to a benign impact, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.687376Binding0.3810.8770.625-3.549Likely Benign0.092Likely BenignLikely Benign0.118Likely Benign-0.08Neutral0.008Benign0.008Benign4.31Benign0.00Affected0.39410.3784102.214.03
c.308G>T
G103V
2D
AIThe SynGAP1 missense variant G103V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.687376Binding0.3810.8770.625-3.584Likely Benign0.151Likely BenignLikely Benign0.126Likely Benign-0.96Neutral0.820Possibly Damaging0.376Benign4.22Benign0.00Affected0.14200.3404-1-34.642.08
c.3090C>A
H1030Q
2D
AIThe SynGAP1 missense variant H1030Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.995856Binding0.3750.7350.500-2.548Likely Benign0.185Likely BenignLikely Benign0.033Likely Benign0.01Neutral0.004Benign0.004Benign2.88Benign0.53Tolerated0.15380.400130-0.3-9.01
c.3090C>G
H1030Q
2D
AIThe SynGAP1 missense variant H1030Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.995856Binding0.3750.7350.500-2.548Likely Benign0.185Likely BenignLikely Benign0.033Likely Benign0.01Neutral0.004Benign0.004Benign2.88Benign0.53Tolerated0.15380.400130-0.3-9.01
c.3091A>C
M1031L
2D
AIThe SynGAP1 missense variant M1031L is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.865454Disordered0.995959Binding0.3400.7360.500-2.213Likely Benign0.162Likely BenignLikely Benign0.056Likely Benign-0.82Neutral0.044Benign0.018Benign2.84Benign0.33Tolerated0.12200.4050421.9-18.03
c.3091A>G
M1031V
2D
AIThe SynGAP1 missense variant M1031V is catalogued in gnomAD (ID 6‑33443643‑A‑G) but has no ClinVar entry. Across the spectrum of in‑silico predictors, every tool listed—REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—consistently scores the variant as benign. No pathogenic predictions are reported. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the uniform benign predictions and the lack of any ClinVar pathogenic classification, the variant is most likely benign and does not contradict existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.865454Disordered0.995959Binding0.3400.7360.5006-33443643-A-G74.34e-6-2.815Likely Benign0.198Likely BenignLikely Benign0.054Likely Benign-0.81Neutral0.002Benign0.003Benign2.72Benign0.44Tolerated3.7750.23050.3388122.3-32.06
c.3091A>T
M1031L
2D
AIThe SynGAP1 missense variant M1031L is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.865454Disordered0.995959Binding0.3400.7360.500-2.213Likely Benign0.162Likely BenignLikely Benign0.056Likely Benign-0.82Neutral0.044Benign0.018Benign2.84Benign0.33Tolerated0.12200.4050421.9-18.03
c.3092T>A
M1031K
2D
AIThe SynGAP1 missense variant M1031K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only AlphaMissense‑Default predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.865454Disordered0.995959Binding0.3400.7360.500-1.940Likely Benign0.709Likely PathogenicLikely Benign0.114Likely Benign-0.80Neutral0.325Benign0.098Benign2.66Benign0.18Tolerated0.12240.14120-1-5.8-3.02
c.3092T>G
M1031R
2D
AIThe SynGAP1 missense variant M1031R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only AlphaMissense‑Default predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Taken together, the majority of evidence points to a benign impact for M1031R, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.865454Disordered0.995959Binding0.3400.7360.500-1.365Likely Benign0.673Likely PathogenicLikely Benign0.117Likely Benign-0.85Neutral0.325Benign0.129Benign2.64Benign0.12Tolerated0.13680.12120-1-6.424.99
c.3093G>A
M1031I
2D
AIThe SynGAP1 missense variant M1031I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only AlphaMissense‑Default predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Taken together, the overwhelming majority of evidence points to a benign impact for M1031I. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing clinical database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.865454Disordered0.995959Binding0.3400.7360.500-3.312Likely Benign0.739Likely PathogenicLikely Benign0.026Likely Benign-0.99Neutral0.095Benign0.027Benign2.71Benign0.25Tolerated0.11280.3324212.6-18.03
c.3093G>C
M1031I
2D
AIThe SynGAP1 missense variant M1031I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only AlphaMissense‑Default predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Taken together, the overwhelming majority of evidence points to a benign impact for M1031I. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing clinical database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.865454Disordered0.995959Binding0.3400.7360.500-3.312Likely Benign0.739Likely PathogenicLikely Benign0.025Likely Benign-0.99Neutral0.095Benign0.027Benign2.71Benign0.25Tolerated0.11280.3324212.6-18.03
c.3093G>T
M1031I
2D
AIThe SynGAP1 missense variant M1031I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only AlphaMissense‑Default predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Taken together, the overwhelming majority of evidence points to a benign impact for M1031I. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing clinical database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.865454Disordered0.995959Binding0.3400.7360.500-3.312Likely Benign0.739Likely PathogenicLikely Benign0.026Likely Benign-0.99Neutral0.095Benign0.027Benign2.71Benign0.25Tolerated0.11280.3324212.6-18.03
c.3094C>A
L1032M
2D
AIThe SynGAP1 missense variant L1032M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of any ClinVar pathogenic annotation. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.865454Disordered0.995318Binding0.3650.7350.500-4.353Likely Benign0.219Likely BenignLikely Benign0.064Likely Benign-0.09Neutral0.995Probably Damaging0.892Possibly Damaging2.66Benign0.10Tolerated0.09350.471942-1.918.03
c.3094C>G
L1032V
2D
AIThe SynGAP1 missense variant L1032V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools, polyPhen‑2 HumDiv and polyPhen‑2 HumVar, predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for the variant, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.865454Disordered0.995318Binding0.3650.7350.500-4.123Likely Benign0.176Likely BenignLikely Benign0.075Likely Benign0.16Neutral0.889Possibly Damaging0.514Possibly Damaging2.78Benign0.78Tolerated0.16370.4353210.4-14.03
c.3095T>A
L1032Q
2D
AIThe SynGAP1 missense variant L1032Q is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the aggregate evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is assigned).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.865454Disordered0.995318Binding0.3650.7350.500-2.992Likely Benign0.467AmbiguousLikely Benign0.134Likely Benign-0.78Neutral0.995Probably Damaging0.892Possibly Damaging2.66Benign0.03Affected0.12170.1677-2-2-7.314.97
c.3095T>C
L1032P
2D
AIThe SynGAP1 missense variant L1032P has no ClinVar entry and is not reported in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and the SGM‑Consensus score all classify the change as benign or likely benign. AlphaMissense‑Optimized also predicts a benign outcome, whereas SIFT uniquely flags the variant as pathogenic. The AlphaMissense‑Default assessment is uncertain, and no Foldetta stability data are available. High‑accuracy analyses reinforce the benign consensus: AlphaMissense‑Optimized reports a benign effect, and the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates benign. Foldetta results are missing, so they do not influence the interpretation. Overall, the majority of computational evidence supports a benign classification, which is consistent with the absence of a ClinVar pathogenic annotation. Thus, the variant is most likely benign, and this conclusion does not contradict ClinVar status, as no ClinVar pathogenic claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.865454Disordered0.995318Binding0.3650.7350.500-2.560Likely Benign0.449AmbiguousLikely Benign0.142Likely Benign-0.71Neutral0.012Benign0.017Benign2.64Benign0.05Affected0.30240.2330-3-3-5.4-16.04
c.3095T>G
L1032R
2D
AIThe SynGAP1 missense variant L1032R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.865454Disordered0.995318Binding0.3650.7350.500-2.658Likely Benign0.707Likely PathogenicLikely Benign0.099Likely Benign-1.03Neutral0.995Probably Damaging0.892Possibly Damaging2.66Benign0.02Affected0.13500.1919-3-2-8.343.03
c.3097T>A
S1033T
2D
AIThe SynGAP1 missense variant S1033T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.910643Disordered0.993473Binding0.2940.7370.625-3.702Likely Benign0.140Likely BenignLikely Benign0.029Likely Benign-0.05Neutral0.568Possibly Damaging0.171Benign2.73Benign0.58Tolerated0.13790.6089110.114.03
c.3097T>C
S1033P
2D
AIThe SynGAP1 missense variant S1033P is not reported in ClinVar and is absent from gnomAD, indicating no documented population frequency. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are not available, so they do not influence the overall assessment. Based on the consensus of all available predictions, the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.910643Disordered0.993473Binding0.2940.7370.625-2.046Likely Benign0.268Likely BenignLikely Benign0.068Likely Benign0.05Neutral0.002Benign0.005Benign2.68Benign0.27Tolerated0.18890.54861-1-0.810.04
c.3097T>G
S1033A
2D
AIThe SynGAP1 missense variant S1033A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable. Overall, the consensus of all available predictions indicates that the variant is most likely benign, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.910643Disordered0.993473Binding0.2940.7370.625-3.107Likely Benign0.121Likely BenignLikely Benign0.033Likely Benign0.06Neutral0.220Benign0.085Benign2.81Benign1.00Tolerated0.43870.5282112.6-16.00
c.3098C>A
S1033Y
2D
AIThe SynGAP1 missense variant S1033Y is reported in gnomAD (ID 6‑33443650‑C‑A) but has no ClinVar entry. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.910643Disordered0.993473Binding0.2940.7370.6256-33443650-C-A16.19e-7-4.857Likely Benign0.564AmbiguousLikely Benign0.034Likely Benign-1.01Neutral0.021Benign0.008Benign2.69Benign0.04Affected3.7750.07080.5262-2-3-0.576.10
c.3098C>G
S1033C
2D
AIThe SynGAP1 missense variant S1033C is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect for S1033C, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.910643Disordered0.993473Binding0.2940.7370.625-6.263Likely Benign0.198Likely BenignLikely Benign0.044Likely Benign-0.39Neutral0.992Probably Damaging0.750Possibly Damaging2.68Benign0.12Tolerated0.10310.57040-13.316.06
c.3098C>T
S1033F
2D
AIThe SynGAP1 missense variant S1033F is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus is Likely Benign, and Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.910643Disordered0.993473Binding0.2940.7370.625-5.013Likely Benign0.555AmbiguousLikely Benign0.022Likely Benign-1.02Neutral0.440Benign0.185Benign2.70Benign0.05Affected0.06990.5546-3-23.660.10
c.3100C>A
P1034T
2D
AIThe SynGAP1 missense variant P1034T is not reported in ClinVar and has no entry in gnomAD, indicating it is not catalogued in these databases. Prediction tools largely agree on a benign effect: SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only two tools predict a pathogenic outcome: SIFT and FATHMM. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of predictions support a benign impact, and this is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.991713Binding0.3430.7520.625-4.367Likely Benign0.285Likely BenignLikely Benign0.026Likely Benign-2.00Neutral0.126Benign0.096Benign2.44Pathogenic0.03Affected0.15180.66200-10.93.99
c.3100C>T
P1034S
2D
AIThe SynGAP1 missense variant P1034S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for P1034S, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.991713Binding0.3430.7520.625-3.730Likely Benign0.262Likely BenignLikely Benign0.054Likely Benign-2.28Neutral0.011Benign0.015Benign2.44Pathogenic0.05Affected0.30440.58531-10.8-10.04
c.3101C>A
P1034H
2D
AIThe SynGAP1 missense variant P1034H is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicting benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) predicts pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of predictions (five pathogenic vs. three benign) lean toward pathogenicity, and this conclusion does not contradict the lack of ClinVar annotation. Thus, the variant is most likely pathogenic based on current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.926919Disordered0.991713Binding0.3430.7520.625-4.634Likely Benign0.540AmbiguousLikely Benign0.083Likely Benign-3.17Deleterious0.938Possibly Damaging0.750Possibly Damaging2.38Pathogenic0.02Affected0.17760.54510-2-1.640.02
c.3101C>G
P1034R
2D
AIThe SynGAP1 P1034R variant has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, SIFT, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, while the SGM Consensus (a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports it as Likely Pathogenic; Foldetta stability analysis is unavailable. Overall, the predictions are mixed, with a slight tilt toward pathogenicity due to the SGM Consensus result and the number of pathogenic calls. The variant is most likely pathogenic based on the current computational evidence, and this assessment does not contradict ClinVar status, as no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.926919Disordered0.991713Binding0.3430.7520.625-3.666Likely Benign0.676Likely PathogenicLikely Benign0.073Likely Benign-3.04Deleterious0.002Benign0.005Benign2.40Pathogenic0.02Affected0.13660.41820-2-2.959.07
c.3101C>T
P1034L
2D
AIThe SynGAP1 missense variant P1034L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Tools that predict a pathogenic effect are PROVEAN and SIFT, while AlphaMissense‑Default is uncertain. The high‑accuracy AlphaMissense‑Optimized model classifies the variant as benign. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also yields a benign prediction (2 benign vs. 1 pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that P1034L is most likely benign, and this assessment does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.926919Disordered0.991713Binding0.3430.7520.625-4.204Likely Benign0.449AmbiguousLikely Benign0.067Likely Benign-3.24Deleterious0.001Benign0.005Benign2.53Benign0.01Affected0.22670.6937-3-35.416.04
c.3103C>G
P1035A
2D
AIThe SynGAP1 missense variant P1035A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic outcome, creating a single discordant signal. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.945666Disordered0.989572Binding0.3000.7560.625-4.293Likely Benign0.241Likely BenignLikely Benign0.041Likely Benign-1.02Neutral0.481Possibly Damaging0.222Benign2.74Benign0.41Tolerated0.31880.60221-13.4-26.04
c.3103C>T
P1035S
2D
AIThe SynGAP1 missense variant P1035S is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign. Only polyPhen‑2 HumDiv flags it as pathogenic, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign outcome. High‑accuracy assessments further support this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus itself is benign; Foldetta results are unavailable. Taken together, the preponderance of evidence points to a benign impact for P1035S, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.945666Disordered0.989572Binding0.3000.7560.625-3.678Likely Benign0.341AmbiguousLikely Benign0.059Likely Benign-0.97Neutral0.818Possibly Damaging0.355Benign2.79Benign0.28Tolerated0.32570.62531-10.8-10.04
c.3104C>A
P1035H
2D
AIThe SynGAP1 missense variant P1035H is not reported in ClinVar and has no entries in gnomAD. Consensus predictions from multiple in‑silico tools are mixed: benign calls come from SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, whereas pathogenic calls are made by polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized predicts a benign effect, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates a likely benign outcome. No Foldetta stability analysis is available for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.945666Disordered0.989572Binding0.3000.7560.625-5.333Likely Benign0.608Likely PathogenicLikely Benign0.058Likely Benign-0.76Neutral0.997Probably Damaging0.889Possibly Damaging2.68Benign0.15Tolerated0.18930.56690-2-1.640.02
c.3104C>G
P1035R
2D
AIThe SynGAP1 missense variant P1035R is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and there is no ClinVar entry to contradict this assessment. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.945666Disordered0.989572Binding0.3000.7560.625-4.534Likely Benign0.604Likely PathogenicLikely Benign0.119Likely Benign1.07Neutral0.970Probably Damaging0.728Possibly Damaging2.89Benign0.93Tolerated0.14240.42010-2-2.959.07
c.3104C>T
P1035L
2D
AIThe SynGAP1 missense variant P1035L is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.945666Disordered0.989572Binding0.3000.7560.625-5.694Likely Benign0.675Likely PathogenicLikely Benign0.071Likely Benign-2.11Neutral0.970Probably Damaging0.728Possibly Damaging2.70Benign0.21Tolerated0.24440.7354-3-35.416.04
c.3106C>A
Q1036K
2D
AIThe SynGAP1 missense variant Q1036K is not reported in ClinVar and has no entry in gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus, REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. High‑accuracy assessments reinforce the benign prediction: AlphaMissense‑Optimized scores the variant as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. No Foldetta stability analysis is available for this variant. Overall, the majority of computational evidence indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.987955Binding0.2750.7650.625-3.757Likely Benign0.646Likely PathogenicLikely Benign0.079Likely Benign-1.72Neutral0.011Benign0.005Benign2.58Benign0.05Affected0.20960.522011-0.40.04
c.3106C>G
Q1036E
2D
AIThe SynGAP1 missense variant Q1036E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign. Only SIFT predicts a pathogenic outcome. When predictions are grouped by consensus, the benign group contains nine tools, while the pathogenic group contains one (SIFT). High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable, so they do not influence the assessment. Overall, the evidence strongly suggests the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.987955Binding0.2750.7650.625-3.797Likely Benign0.313Likely BenignLikely Benign0.056Likely Benign-1.22Neutral0.264Benign0.062Benign2.59Benign0.03Affected0.16290.3484220.00.98
c.3107A>C
Q1036P
2D
AIThe SynGAP1 missense variant Q1036P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as tolerated or benign. In contrast, polyPhen‑2 HumDiv and SIFT predict a damaging or pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign status. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence from multiple prediction algorithms and the consensus score indicates that the variant is most likely benign, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.987955Binding0.2750.7650.625-2.491Likely Benign0.135Likely BenignLikely Benign0.104Likely Benign-2.00Neutral0.802Possibly Damaging0.238Benign2.57Benign0.01Affected0.20180.55640-11.9-31.01
c.3107A>G
Q1036R
2D
AIThe SynGAP1 missense variant Q1036R is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions come from SIFT and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority of the four high‑accuracy tools) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the collective evidence points to a benign effect for Q1036R, and this conclusion does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.987955Binding0.2750.7650.625-3.816Likely Benign0.596Likely PathogenicLikely Benign0.083Likely Benign-1.32Neutral0.292Benign0.071Benign2.54Benign0.04Affected0.17100.307111-1.028.06
c.3107A>T
Q1036L
2D
AIThe SynGAP1 missense variant Q1036L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors a benign outcome, with two benign votes versus one pathogenic and one uncertain. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.948786Disordered0.987955Binding0.2750.7650.625-4.389Likely Benign0.435AmbiguousLikely Benign0.092Likely Benign-2.92Deleterious0.152Benign0.045Benign2.52Benign0.01Affected0.10690.5996-2-27.3-14.97
c.3108G>C
Q1036H
2D
AIThe SynGAP1 missense variant Q1036H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.987955Binding0.2750.7650.625-4.189Likely Benign0.536AmbiguousLikely Benign0.065Likely Benign-1.18Neutral0.977Probably Damaging0.615Possibly Damaging2.50Benign0.29Tolerated3.7750.16410.4835030.39.01
c.3108G>T
Q1036H
2D
AIThe SynGAP1 missense variant Q1036H is listed in gnomAD (ID 6‑33443660‑G‑T) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and Foldetta (FoldX‑MD/Rosetta stability assessment) has no available result. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta data are missing. Overall, the majority of reliable predictors indicate a benign impact, and this is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.987955Binding0.2750.7650.6256-33443660-G-T16.20e-7-4.189Likely Benign0.536AmbiguousLikely Benign0.065Likely Benign-1.18Neutral0.977Probably Damaging0.615Possibly Damaging2.50Benign0.29Tolerated3.7750.16410.4835030.39.01
c.3109A>C
I1037L
2D
AIThe SynGAP1 missense variant I1037L is not reported in ClinVar and is absent from gnomAD, indicating no known clinical or population evidence. Functional prediction tools uniformly favor a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity, and the only uncertain call comes from AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports the variant as “Likely Benign.” High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that I1037L is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-2.563Likely Benign0.448AmbiguousLikely Benign0.074Likely Benign-0.46Neutral0.421Benign0.128Benign2.82Benign0.81Tolerated0.09390.430222-0.70.00
c.3109A>G
I1037V
2D
AIThe SynGAP1 missense variant I1037V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that I1037V is most likely benign, and this conclusion is not contradicted by ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-2.326Likely Benign0.461AmbiguousLikely Benign0.085Likely Benign-0.09Neutral0.421Benign0.128Benign2.76Benign0.93Tolerated0.12290.398543-0.3-14.03
c.3109A>T
I1037F
2D
AIThe SynGAP1 missense variant I1037F is not reported in ClinVar and has no entries in gnomAD. Consensus from multiple in‑silico predictors shows a split: benign predictions come from REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while pathogenic predictions arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy tools further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, is not available for this variant. Overall, the majority of evidence points to a benign effect, and this assessment is consistent with the absence of a ClinVar pathogenic claim. Thus, the variant is most likely benign, and this conclusion does not contradict ClinVar, which has no pathogenic assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-3.517Likely Benign0.653Likely PathogenicLikely Benign0.115Likely Benign-0.97Neutral0.977Probably Damaging0.632Possibly Damaging2.71Benign0.16Tolerated0.06530.372210-1.734.02
c.310C>A
R104S
2D
AIThe SynGAP1 missense variant R104S has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; no Foldetta stability result is available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.678998Binding0.3390.8690.625-2.790Likely Benign0.771Likely PathogenicLikely Benign0.143Likely Benign-0.23Neutral0.625Possibly Damaging0.118Benign4.13Benign0.00Affected0.24900.38060-13.7-69.11
c.310C>G
R104G
2D
AIThe SynGAP1 missense variant R104G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for R104G, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.678998Binding0.3390.8690.625-2.373Likely Benign0.452AmbiguousLikely Benign0.109Likely Benign-0.90Neutral0.835Possibly Damaging0.165Benign4.03Benign0.00Affected0.31110.3625-3-24.1-99.14
c.310C>T
R104C
2D
AIThe SynGAP1 missense variant R104C has no ClinVar entry and is present in gnomAD (ID 6‑33432175‑C‑T). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.678998Binding0.3390.8690.6256-33432175-C-T21.24e-6-5.716Likely Benign0.475AmbiguousLikely Benign0.109Likely Benign-1.41Neutral0.993Probably Damaging0.446Benign3.99Benign0.00Affected4.3210.29540.3292-3-47.0-53.0510.1016/j.ajhg.2020.11.011
c.3110T>A
I1037N
2D
AIThe SynGAP1 missense variant I1037N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a Likely Benign classification, while AlphaMissense‑Optimized remains uncertain. Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-3.955Likely Benign0.832Likely PathogenicAmbiguous0.131Likely Benign1.56Neutral0.666Possibly Damaging0.211Benign2.81Benign0.34Tolerated0.10220.1140-2-3-8.00.94
c.3110T>C
I1037T
2D
AIThe SynGAP1 missense variant I1037T is not reported in ClinVar (ClinVar ID None) but is present in gnomAD (ID 6‑33443662‑T‑C). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. Tools that predict a pathogenic effect are AlphaMissense‑Default and AlphaMissense‑Optimized. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic, while the SGM‑Consensus remains Likely Benign; Foldetta results are unavailable. Overall, the majority of predictions (seven benign vs. two pathogenic) indicate that the variant is most likely benign, and this assessment does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.6256-33443662-T-C16.21e-7-2.565Likely Benign0.973Likely PathogenicLikely Pathogenic0.066Likely Benign0.40Neutral0.292Benign0.110Benign2.79Benign0.34Tolerated3.7750.10710.2175-10-5.2-12.05
c.3110T>G
I1037S
2D
AIThe SynGAP1 missense variant I1037S is not reported in ClinVar and has no entries in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), which classifies the variant as Likely Benign. Only AlphaMissense‑Default predicts a pathogenic outcome, while AlphaMissense‑Optimized is uncertain and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta) has no available result for this variant. Based on the overall consensus of the majority of tools, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-2.247Likely Benign0.935Likely PathogenicAmbiguous0.120Likely Benign0.43Neutral0.032Benign0.017Benign2.83Benign0.27Tolerated0.26340.1110-1-2-5.3-26.08
c.3111C>G
I1037M
2D
AIThe SynGAP1 missense variant I1037M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. Only two tools, polyPhen‑2 HumDiv and polyPhen‑2 HumVar, predict a pathogenic effect. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence supports a benign classification, and this is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-3.849Likely Benign0.333Likely BenignLikely Benign0.093Likely Benign-0.40Neutral0.977Probably Damaging0.721Possibly Damaging2.71Benign0.18Tolerated0.07750.388521-2.618.03
c.3112A>C
T1038P
2D
AIThe SynGAP1 missense variant T1038P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (both HumDiv and HumVar) predict a pathogenic outcome. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.982911Binding0.2790.7940.625-2.196Likely Benign0.390AmbiguousLikely Benign0.116Likely Benign-1.10Neutral0.965Probably Damaging0.611Possibly Damaging2.66Benign0.26Tolerated0.18560.46800-1-0.9-3.99
c.3112A>G
T1038A
2D
AIThe SynGAP1 missense variant T1038A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, whereas only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as likely benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the consensus of the available predictions points to a benign impact, and this is consistent with the lack of ClinVar evidence, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.982911Binding0.2790.7940.625-3.544Likely Benign0.265Likely BenignLikely Benign0.047Likely Benign-0.79Neutral0.649Possibly Damaging0.209Benign2.81Benign0.15Tolerated0.34290.3983102.5-30.03
c.3112A>T
T1038S
2D
AIThe SynGAP1 missense variant T1038S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence supports a benign classification, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.982911Binding0.2790.7940.625-2.693Likely Benign0.198Likely BenignLikely Benign0.101Likely Benign-0.17Neutral0.649Possibly Damaging0.209Benign2.98Benign0.74Tolerated0.28790.403511-0.1-14.03
c.3113C>A
T1038N
2D
AIThe SynGAP1 missense variant T1038N is not reported in ClinVar and has no entries in gnomAD, indicating it has not been catalogued in these databases. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the substitution as benign, while the majority‑vote consensus from SGM (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, and AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates likely benign. No Foldetta stability analysis is available, so folding‑stability evidence is lacking. Overall, the preponderance of computational evidence supports a benign classification for T1038N, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation. Thus, the variant is most likely benign, and this is not contradicted by ClinVar, which has no pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.982911Binding0.2790.7940.625-3.837Likely Benign0.390AmbiguousLikely Benign0.054Likely Benign-1.36Neutral0.818Possibly Damaging0.355Benign2.68Benign0.10Tolerated0.11840.449000-2.813.00
c.3113C>G
T1038S
2D
AIThe SynGAP1 missense variant T1038S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence supports a benign classification, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.982911Binding0.2790.7940.625-2.693Likely Benign0.198Likely BenignLikely Benign0.102Likely Benign-0.17Neutral0.649Possibly Damaging0.209Benign2.98Benign0.74Tolerated0.28790.403511-0.1-14.03
c.3113C>T
T1038I
2D
AIThe SynGAP1 T1038I missense variant has no ClinVar record and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), which classifies the variant as Likely Benign. Tools that predict a pathogenic outcome are polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. The high‑accuracy AlphaMissense‑Optimized score is Uncertain, and the Foldetta protein‑folding stability assessment is unavailable. Overall, the balance of evidence leans toward a benign interpretation, with one high‑accuracy tool inconclusive and no conflicting ClinVar annotation. Thus, the variant is most likely benign, and there is no ClinVar status that contradicts this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.982911Binding0.2790.7940.625-4.552Likely Benign0.877Likely PathogenicAmbiguous0.093Likely Benign-2.02Neutral0.990Probably Damaging0.637Possibly Damaging2.69Benign0.04Affected0.10120.50360-15.212.05
c.3115A>C
I1039L
2D
AIThe SynGAP1 missense variant I1039L is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, is not available for this variant. Overall, the consensus of all available predictions strongly supports a benign classification, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.979204Binding0.2920.8060.625-2.035Likely Benign0.269Likely BenignLikely Benign0.083Likely Benign-0.14Neutral0.264Benign0.048Benign2.82Benign0.98Tolerated0.10570.460522-0.70.00
c.3115A>G
I1039V
2D
AIThe SynGAP1 missense variant I1039V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.979204Binding0.2920.8060.625-2.455Likely Benign0.164Likely BenignLikely Benign0.060Likely Benign0.21Neutral0.264Benign0.048Benign2.76Benign0.41Tolerated0.14050.411243-0.3-14.03
c.3115A>T
I1039F
2D
AIThe SynGAP1 missense variant I1039F is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign interpretation: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict benign, while the majority of other predictors (polyPhen‑2 HumDiv and HumVar) indicate pathogenic. When predictions are grouped by agreement, the benign‑oriented tools outnumber the pathogenic ones, and the single uncertain call from AlphaMissense‑Default does not alter this balance. High‑accuracy assessments reinforce the benign trend: AlphaMissense‑Optimized scores the variant as benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports it as Likely Benign. Foldetta data are unavailable. Overall, the computational evidence overwhelmingly supports a benign effect, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.979204Binding0.2920.8060.625-2.872Likely Benign0.545AmbiguousLikely Benign0.124Likely Benign-1.16Neutral0.925Possibly Damaging0.510Possibly Damaging2.68Benign0.13Tolerated0.07100.436810-1.734.02
c.3116T>A
I1039N
2D
AIThe SynGAP1 missense variant I1039N has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar status (none is present). Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.979204Binding0.2920.8060.625-3.469Likely Benign0.951Likely PathogenicAmbiguous0.155Likely Benign-1.24Neutral0.011Benign0.010Benign2.67Benign0.02Affected0.11510.1311-2-3-8.00.94
c.3116T>G
I1039S
2D
AIThe SynGAP1 missense variant I1039S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM all classify the substitution as benign. In contrast, SIFT and AlphaMissense‑Default predict a pathogenic impact. The high‑accuracy AlphaMissense‑Optimized score is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. No Foldetta stability assessment is available. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.979204Binding0.2920.8060.625-1.688Likely Benign0.829Likely PathogenicAmbiguous0.171Likely Benign-0.20Neutral0.032Benign0.008Benign2.76Benign0.03Affected0.29170.1294-1-2-5.3-26.08
c.3117T>G
I1039M
2D
AIThe SynGAP1 missense variant I1039M is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for I1039M, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.979204Binding0.2920.8060.625-3.444Likely Benign0.292Likely BenignLikely Benign0.116Likely Benign-0.38Neutral0.977Probably Damaging0.721Possibly Damaging2.68Benign0.16Tolerated0.09260.439221-2.618.03
c.3118G>A
G1040S
2D
AIThe SynGAP1 missense variant G1040S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include PROVEAN, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are REVEL, polyPhen‑2 HumDiv, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence (six benign versus four pathogenic predictions) points to a benign impact for G1040S. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.964893Disordered0.973805Binding0.3320.8160.625-2.179Likely Benign0.307Likely BenignLikely Benign0.653Likely Pathogenic-1.81Neutral0.827Possibly Damaging0.375Benign-0.74Pathogenic0.02Affected0.23320.529810-0.430.03
c.3118G>C
G1040R
2D
AIThe SynGAP1 missense variant G1040R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely converge on a deleterious effect: pathogenic calls are made by REVEL, PROVEAN, polyPhen‑2 HumDiv, SIFT, FATHMM, AlphaMissense‑Default, and the SGM‑Consensus (which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Benign predictions are limited to polyPhen‑2 HumVar and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, while the SGM‑Consensus remains pathogenic. Foldetta, a protein‑folding stability predictor, has no available result for this residue. Taken together, the majority of evidence supports a pathogenic classification, and this conclusion does not conflict with the absence of a ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.964893Disordered0.973805Binding0.3320.8160.625-2.901Likely Benign0.949Likely PathogenicAmbiguous0.704Likely Pathogenic-3.00Deleterious0.463Possibly Damaging0.194Benign-0.74Pathogenic0.00Affected0.09240.4415-3-2-4.199.14
c.3118G>T
G1040C
2D
AIThe SynGAP1 missense variant G1040C is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a deleterious effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default all predict pathogenicity, while ESM1b and AlphaMissense‑Optimized predict a benign outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Pathogenic. High‑accuracy assessments further support this view: AlphaMissense‑Optimized reports a benign prediction, whereas the SGM‑Consensus remains Likely Pathogenic; the Foldetta stability analysis is unavailable. Overall, the preponderance of evidence from multiple in silico tools indicates that the variant is most likely pathogenic, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.964893Disordered0.973805Binding0.3320.8160.625-6.272Likely Benign0.620Likely PathogenicLikely Benign0.744Likely Pathogenic-3.04Deleterious0.999Probably Damaging0.917Probably Damaging-0.74Pathogenic0.00Affected0.11550.4556-3-32.946.09
c.3119G>A
G1040D
2D
AIThe SynGAP1 missense variant G1040D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include only ESM1b, whereas the remaining tools—REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus—predict a pathogenic impact. The high‑accuracy assessments further support this: AlphaMissense‑Optimized classifies the variant as pathogenic, the SGM‑Consensus (a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) labels it likely pathogenic, and the Foldetta stability analysis is unavailable. Overall, the preponderance of evidence indicates that G1040D is most likely pathogenic, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.964893Disordered0.973805Binding0.3320.8160.625-4.154Likely Benign0.956Likely PathogenicLikely Pathogenic0.761Likely Pathogenic-2.82Deleterious0.986Probably Damaging0.787Possibly Damaging-0.74Pathogenic0.00Affected0.16770.20421-1-3.158.04
c.3119G>C
G1040A
2D
AIThe SynGAP1 missense variant G1040A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are REVEL and FATHMM, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote among AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign prediction (2 benign vs. 1 pathogenic). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation, as the variant is not yet classified in that database.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.964893Disordered0.973805Binding0.3320.8160.625-2.625Likely Benign0.409AmbiguousLikely Benign0.606Likely Pathogenic-1.65Neutral0.114Benign0.030Benign-0.74Pathogenic0.30Tolerated0.32460.5331102.214.03
c.311G>A
R104H
2D
AIThe SynGAP1 missense variant R104H is reported in gnomAD (variant ID 6‑33432176‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is also benign. Foldetta results are not available for this variant. Overall, the preponderance of evidence indicates that R104H is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.678998Binding0.3390.8690.6256-33432176-G-A21.24e-6-4.126Likely Benign0.268Likely BenignLikely Benign0.094Likely Benign-1.42Neutral0.066Benign0.004Benign4.02Benign0.00Affected4.3210.24310.2102021.3-19.05
c.311G>C
R104P
2D
AIThe SynGAP1 missense variant R104P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.678998Binding0.3390.8690.625-3.184Likely Benign0.510AmbiguousLikely Benign0.200Likely Benign-0.88Neutral0.947Possibly Damaging0.410Benign4.01Benign0.00Affected0.17590.44980-22.9-59.07
c.3121C>A
P1041T
2D
AIThe SynGAP1 missense variant P1041T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is benign, and this conclusion does not contradict any ClinVar annotation (none present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.962114Disordered0.967463Binding0.3450.8330.625-5.009Likely Benign0.187Likely BenignLikely Benign0.361Likely Benign-2.45Neutral0.051Benign0.025Benign5.50Benign0.10Tolerated0.16320.66990-10.93.99
c.3121C>G
P1041A
2D
AIThe SynGAP1 missense variant P1041A is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and polyPhen‑2 HumDiv. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; the Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.962114Disordered0.967463Binding0.3450.8330.625-4.597Likely Benign0.157Likely BenignLikely Benign0.331Likely Benign-2.73Deleterious0.798Possibly Damaging0.283Benign5.53Benign0.24Tolerated0.31540.59391-13.4-26.04
c.3122C>A
P1041H
2D
AIThe SynGAP1 missense variant P1041H is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction, and Foldetta’s protein‑folding stability result is unavailable. Overall, the majority of high‑confidence tools predict a benign impact, and there is no conflict with ClinVar status because the variant has not been reported there. Thus, based on current predictions, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.962114Disordered0.967463Binding0.3450.8330.625-5.312Likely Benign0.377AmbiguousLikely Benign0.476Likely Benign-3.32Deleterious0.999Probably Damaging0.917Probably Damaging5.45Benign0.03Affected0.18830.54340-2-1.640.02
c.3122C>G
P1041R
2D
AIThe SynGAP1 missense variant P1041R is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. The AlphaMissense‑Default result is uncertain, and no Foldetta stability data are available, so these are treated as unavailable. Overall, six tools support a benign classification while three support pathogenicity, and the high‑accuracy AlphaMissense‑Optimized and SGM Consensus both predict benign. Therefore, the variant is most likely benign based on the current predictions, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.962114Disordered0.967463Binding0.3450.8330.625-4.808Likely Benign0.545AmbiguousLikely Benign0.443Likely Benign-3.33Deleterious0.986Probably Damaging0.787Possibly Damaging5.46Benign0.07Tolerated0.14010.42920-2-2.959.07
c.3122C>T
P1041L
2D
AIThe SynGAP1 missense variant P1041L is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and polyPhen‑2 HumDiv. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also resolves to benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact. This conclusion does not contradict ClinVar, which has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.962114Disordered0.967463Binding0.3450.8330.625-4.901Likely Benign0.399AmbiguousLikely Benign0.403Likely Benign-3.14Deleterious0.905Possibly Damaging0.375Benign5.46Benign1.00Tolerated0.23570.6664-3-35.416.04
c.3124C>A
Q1042K
2D
AIThe SynGAP1 missense variant Q1042K is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the collective predictions strongly suggest that the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.959333Binding0.3100.8460.625-4.331Likely Benign0.498AmbiguousLikely Benign0.304Likely Benign-1.52Neutral0.224Benign0.091Benign5.44Benign0.13Tolerated0.23380.520211-0.40.04
c.3124C>G
Q1042E
2D
AIThe SynGAP1 missense variant Q1042E is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.959333Binding0.3100.8460.625-4.231Likely Benign0.262Likely BenignLikely Benign0.267Likely Benign-1.12Neutral0.224Benign0.077Benign5.44Benign0.15Tolerated0.20420.3276220.00.98
c.3125A>C
Q1042P
2D
AIThe SynGAP1 missense variant Q1042P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only polyPhen‑2 HumDiv indicates a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Overall, the consensus of the available predictions points to a benign effect, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.959333Binding0.3100.8460.625-2.085Likely Benign0.060Likely BenignLikely Benign0.461Likely Benign-0.73Neutral0.586Possibly Damaging0.223Benign5.42Benign0.31Tolerated0.23360.57620-11.9-31.01
c.3125A>T
Q1042L
2D
AIThe SynGAP1 missense variant Q1042L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.959333Binding0.3100.8460.625-3.796Likely Benign0.203Likely BenignLikely Benign0.338Likely Benign-2.47Neutral0.369Benign0.120Benign5.47Benign0.05Affected0.14690.6276-2-27.3-14.97
c.3126G>C
Q1042H
2D
AIThe SynGAP1 missense variant Q1042H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.959333Binding0.3100.8460.625-4.258Likely Benign0.335Likely BenignLikely Benign0.302Likely Benign-1.54Neutral0.938Possibly Damaging0.596Possibly Damaging5.42Benign0.03Affected0.22070.4671300.39.01
c.3126G>T
Q1042H
2D
AIThe SynGAP1 missense variant Q1042H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized returns Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.959333Binding0.3100.8460.625-4.258Likely Benign0.335Likely BenignLikely Benign0.302Likely Benign-1.54Neutral0.938Possibly Damaging0.596Possibly Damaging5.42Benign0.03Affected0.22070.4671300.39.01
c.3127A>G
R1043G
2D
AIThe SynGAP1 missense variant R1043G is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.954069Binding0.2990.8530.625-2.168Likely Benign0.201Likely BenignLikely Benign0.383Likely Benign-3.17Deleterious0.130Benign0.049Benign5.94Benign0.00Affected0.31790.3697-3-24.1-99.14
c.3127A>T
R1043W
2D
AIThe SynGAP1 missense variant R1043W is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields a benign prediction; Foldetta results are unavailable. Overall, the majority of high‑confidence tools predict a benign impact, and there is no ClinVar annotation to contradict this assessment. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.978672Disordered0.954069Binding0.2990.8530.625-6.382Likely Benign0.523AmbiguousLikely Benign0.444Likely Benign-3.43Deleterious0.971Probably Damaging0.729Possibly Damaging5.38Benign0.00Affected0.14030.36962-33.630.03
c.3128G>A
R1043K
2D
AIThe SynGAP1 missense variant R1043K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar or gnomAD entries—there is no contradiction with existing database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.954069Binding0.2990.8530.625-4.038Likely Benign0.162Likely BenignLikely Benign0.376Likely Benign-1.41Neutral0.069Benign0.033Benign5.39Benign0.00Affected0.51410.4070Weaken320.6-28.01
c.3128G>C
R1043T
2D
AIThe SynGAP1 missense variant R1043T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.954069Binding0.2990.8530.625-3.928Likely Benign0.298Likely BenignLikely Benign0.463Likely Benign-1.77Neutral0.001Benign0.003Benign5.39Benign0.00Affected0.19750.5513-1-13.8-55.08
c.3128G>T
R1043M
2D
AIThe SynGAP1 missense variant R1043M is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Consensus predictions from multiple in‑silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict benign, while polyPhen‑2 HumDiv and SIFT predict pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus also indicates Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for R1043M, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.954069Binding0.2990.8530.625-4.800Likely Benign0.510AmbiguousLikely Benign0.471Likely Benign-1.98Neutral0.744Possibly Damaging0.229Benign5.38Benign0.00Affected0.19820.44680-16.4-24.99
c.3129G>C
R1043S
2D
AIThe SynGAP1 missense variant R1043S is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools cluster into two groups: benign predictions include PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions come from REVEL and SIFT. AlphaMissense‑Default is uncertain, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized scores benign, SGM‑Consensus is likely benign, and Foldetta results are unavailable. Taken together, the majority of evidence points to a benign impact for R1043S. This conclusion is consistent with the absence of a ClinVar assertion, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.954069Binding0.2990.8530.625-3.223Likely Benign0.457AmbiguousLikely Benign0.509Likely Pathogenic-2.10Neutral0.036Benign0.018Benign5.42Benign0.00Affected3.7750.27270.4628-103.7-69.11
c.3130C>A
P1044T
2D
AIThe SynGAP1 missense variant P1044T is catalogued in gnomAD (ID 6‑33443682‑C‑A) but has no ClinVar entry. Across a broad panel of in silico predictors, every tool reports a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool in the set predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized returns a benign prediction, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, was not available for this variant. Overall, the computational evidence overwhelmingly supports a benign effect, and this is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.952126Binding0.3310.8550.7506-33443682-C-A16.20e-7-4.605Likely Benign0.075Likely BenignLikely Benign0.372Likely Benign-1.02Neutral0.126Benign0.096Benign5.53Benign0.17Tolerated3.7750.16810.6860-100.93.99
c.3130C>G
P1044A
2D
AIThe SynGAP1 missense variant P1044A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly supports a benign classification, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.952126Binding0.3310.8550.750-3.957Likely Benign0.059Likely BenignLikely Benign0.359Likely Benign-1.07Neutral0.059Benign0.061Benign5.50Benign0.18Tolerated0.31940.58501-13.4-26.04
c.3130C>T
P1044S
2D
AIThe SynGAP1 missense variant P1044S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.952126Binding0.3310.8550.750-4.114Likely Benign0.078Likely BenignLikely Benign0.311Likely Benign-0.79Neutral0.011Benign0.015Benign5.51Benign0.14Tolerated0.31940.60811-10.8-10.04
c.3131C>A
P1044Q
2D
AIThe SynGAP1 missense variant P1044Q is not reported in ClinVar and is absent from gnomAD. All evaluated in‑silico predictors—REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods likewise support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.952126Binding0.3310.8550.750-4.439Likely Benign0.091Likely BenignLikely Benign0.338Likely Benign0.51Neutral0.004Benign0.015Benign5.43Benign0.45Tolerated0.15440.55910-1-1.931.01
c.3131C>G
P1044R
2D
AIThe SynGAP1 missense variant P1044R is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign classification, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.952126Binding0.3310.8550.750-3.969Likely Benign0.242Likely BenignLikely Benign0.368Likely Benign0.79Neutral0.259Benign0.140Benign5.45Benign1.00Tolerated0.14510.42700-2-2.959.07
c.3131C>T
P1044L
2D
AIThe SynGAP1 missense variant P1044L is not represented in ClinVar (no ClinVar ID) and is absent from gnomAD. All evaluated in‑silico predictors classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool reports a pathogenic or likely pathogenic outcome. High‑accuracy assessments reinforce this benign prediction: AlphaMissense‑Optimized indicates benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.952126Binding0.3310.8550.750-4.327Likely Benign0.144Likely BenignLikely Benign0.418Likely Benign-1.64Neutral0.411Benign0.187Benign5.43Benign0.15Tolerated0.22640.6586-3-35.416.04
c.3133G>A
A1045T
2D
AIThe SynGAP1 missense variant A1045T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly supports a benign classification, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975609Disordered0.948874Binding0.3520.8820.750-4.531Likely Benign0.074Likely BenignLikely Benign0.059Likely Benign0.03Neutral0.004Benign0.010Benign2.68Benign0.52Tolerated0.18570.668210-2.530.03
c.3133G>C
A1045P
2D
AIThe SynGAP1 missense variant A1045P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also predicts Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975609Disordered0.948874Binding0.3520.8820.750-2.260Likely Benign0.078Likely BenignLikely Benign0.099Likely Benign1.09Neutral0.586Possibly Damaging0.223Benign2.64Benign0.24Tolerated0.21300.53321-1-3.426.04
c.3133G>T
A1045S
2D
AIThe SynGAP1 missense variant A1045S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975609Disordered0.948874Binding0.3520.8820.750-3.724Likely Benign0.073Likely BenignLikely Benign0.055Likely Benign-0.11Neutral0.011Benign0.010Benign2.66Benign0.46Tolerated0.26480.549311-2.616.00
c.3134C>A
A1045D
2D
AIThe SynGAP1 missense variant A1045D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that reach consensus all indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all score the variant as benign. AlphaMissense‑Optimized also predicts a benign outcome, whereas AlphaMissense‑Default remains uncertain. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as “Likely Benign.” No tools predict pathogenicity. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the collective predictions strongly suggest that A1045D is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975609Disordered0.948874Binding0.3520.8820.750-5.734Likely Benign0.418AmbiguousLikely Benign0.066Likely Benign-1.00Neutral0.411Benign0.172Benign2.64Benign0.16Tolerated0.19540.21020-2-5.344.01
c.3134C>T
A1045V
2D
AIThe SynGAP1 missense variant A1045V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975609Disordered0.948874Binding0.3520.8820.750-4.229Likely Benign0.076Likely BenignLikely Benign0.035Likely Benign-0.35Neutral0.011Benign0.017Benign3.06Benign1.00Tolerated0.14870.5474002.428.05
c.3136C>A
P1046T
2D
AIThe SynGAP1 missense variant P1046T is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; the Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.970265Disordered0.942366Binding0.3640.8980.750-5.249Likely Benign0.068Likely BenignLikely Benign0.052Likely Benign-1.18Neutral0.411Benign0.131Benign2.37Pathogenic0.21Tolerated0.14300.59340-10.93.99
c.3136C>T
P1046S
2D
AIThe SynGAP1 missense variant P1046S is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; the Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of computational evidence indicates a benign effect, and this consensus does not contradict any ClinVar status (none is available). Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.970265Disordered0.942366Binding0.3640.8980.750-3.909Likely Benign0.059Likely BenignLikely Benign0.096Likely Benign-0.72Neutral0.126Benign0.096Benign2.39Pathogenic0.70Tolerated0.29290.57441-10.8-10.04
c.3137C>A
P1046H
2D
AIThe SynGAP1 missense variant P1046H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for P1046H. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.970265Disordered0.942366Binding0.3640.8980.750-5.715Likely Benign0.148Likely BenignLikely Benign0.035Likely Benign-1.64Neutral0.832Possibly Damaging0.670Possibly Damaging2.33Pathogenic0.07Tolerated0.15850.52500-2-1.640.02
c.3137C>G
P1046R
2D
AIThe SynGAP1 missense variant P1046R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) all classify the change as benign or likely benign. Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized returns a benign prediction, and the SGM‑Consensus also indicates a likely benign status. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.970265Disordered0.942366Binding0.3640.8980.750-4.929Likely Benign0.222Likely BenignLikely Benign0.077Likely Benign-1.79Neutral0.002Benign0.005Benign2.38Pathogenic0.07Tolerated0.12670.38410-2-2.959.07
c.3137C>T
P1046L
2D
AIThe SynGAP1 missense variant P1046L is reported in gnomAD (ID 6‑33443689‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. In contrast, SIFT and FATHMM predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign; Foldetta results are unavailable. Overall, the preponderance of evidence from multiple independent predictors and the consensus analysis points to a benign classification. This conclusion is consistent with the absence of a ClinVar pathogenic report, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.970265Disordered0.942366Binding0.3640.8980.7506-33443689-C-T16.20e-7-5.022Likely Benign0.116Likely BenignLikely Benign0.100Likely Benign-2.11Neutral0.001Benign0.005Benign2.35Pathogenic0.05Affected3.7750.20360.6442-3-35.416.04
c.3139T>A
S1047T
2D
AIThe SynGAP1 missense variant S1047T is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign status. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.963420Disordered0.933764Binding0.4090.9090.750-4.222Likely Benign0.070Likely BenignLikely Benign0.029Likely Benign0.23Neutral0.069Benign0.049Benign2.63Benign0.63Tolerated0.17960.6265110.114.03
c.3139T>C
S1047P
2D
AIThe SynGAP1 missense variant S1047P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only SIFT indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also classifies the variant as likely benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions points to a benign impact, and this is consistent with the lack of any ClinVar pathogenic annotation. Thus, the variant is most likely benign, and this does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.963420Disordered0.933764Binding0.4090.9090.750-2.415Likely Benign0.076Likely BenignLikely Benign0.064Likely Benign0.52Neutral0.001Benign0.001Benign2.62Benign0.03Affected0.23730.56561-1-0.810.04
c.3139T>G
S1047A
2D
AIThe SynGAP1 missense variant S1047A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable. Overall, the consensus of all available predictions indicates that the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.963420Disordered0.933764Binding0.4090.9090.750-3.503Likely Benign0.060Likely BenignLikely Benign0.040Likely Benign-0.50Neutral0.001Benign0.002Benign2.65Benign0.07Tolerated0.44600.5548112.6-16.00
c.313T>A
S105T
2D
AIThe SynGAP1 missense variant S105T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The high‑accuracy consensus, SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a benign effect. AlphaMissense‑Optimized independently scores the variant as benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.669201Binding0.3640.8700.625-4.166Likely Benign0.132Likely BenignLikely Benign0.055Likely Benign-0.54Neutral0.012Benign0.007Benign4.06Benign0.00Affected0.15830.5212110.114.03
c.313T>G
S105A
2D
AIThe SynGAP1 missense variant S105A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect. The predictions do not contradict ClinVar status, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.669201Binding0.3640.8700.625-3.779Likely Benign0.115Likely BenignLikely Benign0.046Likely Benign-0.67Neutral0.012Benign0.002Benign4.11Benign0.00Affected0.52990.4214Weaken112.6-16.00
c.3142G>A
G1048R
2D
AIThe SynGAP1 missense variant G1048R is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Functional prediction tools show a split: pathogenic calls come from REVEL, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar, whereas benign calls are made by PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus, derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a benign majority, and AlphaMissense‑Optimized itself predicts benign. The SGM‑Consensus, which aggregates these four predictors, reports a likely benign classification. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the absence of a ClinVar assertion; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.923876Binding0.3460.9160.750-4.305Likely Benign0.435AmbiguousLikely Benign0.503Likely Pathogenic-0.54Neutral0.919Possibly Damaging0.728Possibly Damaging2.54Benign0.10Tolerated3.7750.09560.4332-2-3-4.199.14
c.3142G>T
G1048W
2D
AIThe SynGAP1 missense variant G1048W is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.923876Binding0.3460.9160.750-8.803Likely Pathogenic0.340Likely BenignLikely Benign0.498Likely Benign-1.52Neutral0.996Probably Damaging0.961Probably Damaging2.54Benign0.02Affected0.08520.4046-7-2-0.5129.16
c.3143G>A
G1048E
2D
AIThe SynGAP1 missense variant G1048E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only REVEL predicts a pathogenic outcome, while ESM1b is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect. The variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.923876Binding0.3460.9160.750-7.028In-Between0.331Likely BenignLikely Benign0.529Likely Pathogenic-0.62Neutral0.018Benign0.030Benign2.54Benign0.10Tolerated0.14440.40630-2-3.172.06
c.3143G>C
G1048A
2D
AISynGAP1 missense variant G1048A is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only polyPhen‑2 HumDiv predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” status. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that G1048A is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.923876Binding0.3460.9160.750-4.821Likely Benign0.079Likely BenignLikely Benign0.456Likely Benign-0.14Neutral0.573Possibly Damaging0.358Benign2.57Benign0.64Tolerated0.33010.5138102.214.03
c.3143G>T
G1048V
2D
AIThe SynGAP1 missense variant G1048V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are REVEL, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. Thus, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.923876Binding0.3460.9160.750-6.108Likely Benign0.079Likely BenignLikely Benign0.520Likely Pathogenic-0.59Neutral0.958Probably Damaging0.787Possibly Damaging2.54Benign0.11Tolerated0.13120.3688-1-34.642.08
c.3145C>A
P1049T
2D
AIThe SynGAP1 missense variant P1049T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and SIFT—suggest a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta results are unavailable, so no additional stability evidence is present. Overall, the consensus of available predictions indicates that P1049T is most likely benign, and this assessment does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.917915Binding0.4280.9200.750-5.100Likely Benign0.056Likely BenignLikely Benign0.088Likely Benign-1.18Neutral0.519Possibly Damaging0.222Benign2.74Benign0.02Affected0.17910.55140-10.93.99
c.3145C>G
P1049A
2D
AIThe SynGAP1 missense variant P1049A is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.917915Binding0.4280.9200.750-3.870Likely Benign0.049Likely BenignLikely Benign0.055Likely Benign-1.43Neutral0.180Benign0.171Benign2.81Benign0.06Tolerated0.33060.48971-13.4-26.04
c.3145C>T
P1049S
2D
AIThe SynGAP1 missense variant P1049S is reported in gnomAD (variant ID 6‑33443697‑C‑T) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the majority of predictions, including the high‑accuracy tools, indicate that P1049S is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.917915Binding0.4280.9200.7506-33443697-C-T21.24e-6-2.351Likely Benign0.053Likely BenignLikely Benign0.071Likely Benign-1.53Neutral0.519Possibly Damaging0.303Benign2.76Benign0.04Affected3.7750.31440.5083-110.8-10.04
c.3146C>A
P1049H
2D
AIThe SynGAP1 missense variant P1049H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.917915Binding0.4280.9200.750-5.427Likely Benign0.115Likely BenignLikely Benign0.066Likely Benign-2.06Neutral0.978Probably Damaging0.750Possibly Damaging2.76Benign0.01Affected0.18000.50700-2-1.640.02
c.3146C>G
P1049R
2D
AIThe SynGAP1 missense variant P1049R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized returns Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability prediction is available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.917915Binding0.4280.9200.750-5.144Likely Benign0.145Likely BenignLikely Benign0.067Likely Benign-1.90Neutral0.791Possibly Damaging0.500Possibly Damaging2.74Benign0.03Affected0.13760.37690-2-2.959.07
c.3146C>T
P1049L
2D
AIThe SynGAP1 missense variant P1049L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.917915Binding0.4280.9200.750-4.819Likely Benign0.099Likely BenignLikely Benign0.097Likely Benign-2.37Neutral0.001Benign0.002Benign2.71Benign0.02Affected0.22670.5838-3-35.416.04
c.3148G>A
G1050R
2D
AIThe SynGAP1 missense variant G1050R is catalogued in gnomAD (ID 6‑33443700‑G‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. Only FATHMM predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields a benign verdict, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.906802Binding0.3700.9280.8756-33443700-G-A31.86e-6-6.637Likely Benign0.349AmbiguousLikely Benign0.045Likely Benign-0.68Neutral0.009Benign0.008Benign2.48Pathogenic0.06Tolerated3.7750.09390.4532-2-3-4.199.14
c.3148G>C
G1050R
2D
AIThe SynGAP1 missense variant G1050R is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. Only FATHMM predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, and the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign majority vote. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact; this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.906802Binding0.3700.9280.875-6.637Likely Benign0.349AmbiguousLikely Benign0.045Likely Benign-0.68Neutral0.009Benign0.008Benign2.48Pathogenic0.06Tolerated3.7750.09390.4532-2-3-4.199.14
c.3149G>A
G1050E
2D
AIThe SynGAP1 missense variant G1050E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect. There is no ClinVar entry to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.906802Binding0.3700.9280.875-8.175Likely Pathogenic0.266Likely BenignLikely Benign0.071Likely Benign-0.28Neutral0.411Benign0.171Benign2.50Benign0.08Tolerated0.14180.42580-2-3.172.06
c.3149G>C
G1050A
2D
AIThe SynGAP1 missense variant G1050A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.906802Binding0.3700.9280.875-5.514Likely Benign0.074Likely BenignLikely Benign0.047Likely Benign0.18Neutral0.000Benign0.004Benign2.68Benign1.00Tolerated0.33490.5133102.214.03
c.3149G>T
G1050V
2D
AIThe SynGAP1 missense variant G1050V is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; the Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently contains no classification for G1050V.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.906802Binding0.3700.9280.875-6.450Likely Benign0.108Likely BenignLikely Benign0.066Likely Benign-0.83Neutral0.126Benign0.096Benign2.49Pathogenic0.13Tolerated0.12600.3684-1-34.642.08
c.314C>G
S105W
2D
AIThe SynGAP1 missense variant S105W is catalogued in gnomAD (ID 6‑33432179‑C‑G) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” status, reflecting the majority of benign calls. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also leans benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.788093Disordered0.669201Binding0.3640.8700.6256-33432179-C-G21.24e-6-5.600Likely Benign0.606Likely PathogenicLikely Benign0.177Likely Benign-2.28Neutral0.998Probably Damaging0.844Possibly Damaging3.97Benign0.00Affected4.3210.07050.4984-3-2-0.199.14
c.3151G>A
G1051S
2D
AIThe SynGAP1 missense variant G1051S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only FATHMM predicts a pathogenic outcome. When the predictions are grouped, the benign consensus includes eight tools, whereas the pathogenic consensus contains a single tool. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports a benign effect, and the SGM‑Consensus—derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also indicates a likely benign outcome. Foldetta data are unavailable, so no stability inference can be drawn. Overall, the computational evidence overwhelmingly supports a benign classification for G1051S, and this conclusion is consistent with the absence of any ClinVar annotation. Thus, the variant is most likely benign, and this assessment does not contradict ClinVar status, which is currently unreported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.900141Binding0.3580.9360.875-4.742Likely Benign0.079Likely BenignLikely Benign0.445Likely Benign0.10Neutral0.245Benign0.096Benign-0.74Pathogenic0.61Tolerated0.24460.491110-0.430.03
c.3151G>C
G1051R
2D
AIThe SynGAP1 missense variant G1051R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and FATHMM. Two tools (ESM1b and AlphaMissense‑Default) are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because it contains one pathogenic, one benign, and two uncertain calls, and Foldetta results are unavailable. Overall, the balance of evidence favors a benign classification. This conclusion does not contradict ClinVar status, as the variant has no ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.900141Binding0.3580.9360.875-7.907In-Between0.346AmbiguousLikely Benign0.438Likely Benign0.20Neutral0.761Possibly Damaging0.305Benign-0.74Pathogenic0.20Tolerated0.09560.4342-3-2-4.199.14
c.3152G>C
G1051A
2D
AIThe SynGAP1 missense variant G1051A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence indicates a benign effect, and this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.900141Binding0.3580.9360.875-6.406Likely Benign0.081Likely BenignLikely Benign0.406Likely Benign-0.14Neutral0.009Benign0.004Benign-0.74Pathogenic1.00Tolerated0.33530.4944102.214.03
c.3152G>T
G1051V
2D
AIThe SynGAP1 missense variant G1051V is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33443704‑G‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields a benign prediction (2 benign vs. 1 pathogenic, 1 uncertain). Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign effect for G1051V, and this conclusion does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.900141Binding0.3580.9360.8756-33443704-G-T16.20e-7-7.098In-Between0.102Likely BenignLikely Benign0.460Likely Benign-0.62Neutral0.245Benign0.096Benign-0.74Pathogenic0.17Tolerated3.7750.12740.3680-3-14.642.08
c.3154G>C
G1052R
2D
AIThe SynGAP1 missense variant G1052R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and ESM1b predict a pathogenic outcome; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.984420Disordered0.892068Binding0.3670.9380.875-9.050Likely Pathogenic0.383AmbiguousLikely Benign0.497Likely Benign-0.41Neutral0.990Probably Damaging0.798Possibly Damaging3.90Benign0.10Tolerated3.7750.09760.4142-2-3-4.199.14
c.3154G>T
G1052W
2D
AIThe SynGAP1 missense variant G1052W is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984420Disordered0.892068Binding0.3670.9380.875-11.322Likely Pathogenic0.309Likely BenignLikely Benign0.457Likely Benign-0.90Neutral0.997Probably Damaging0.946Probably Damaging3.90Benign0.02Affected0.08720.4046-7-2-0.5129.16
c.3155G>A
G1052E
2D
AIThe SynGAP1 missense variant G1052E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a neutral impact. In contrast, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b predict a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates a likely benign effect. Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign classification, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984420Disordered0.892068Binding0.3670.9380.875-9.869Likely Pathogenic0.287Likely BenignLikely Benign0.448Likely Benign-0.64Neutral0.901Possibly Damaging0.537Possibly Damaging3.90Benign0.12Tolerated0.14050.38730-2-3.172.06
c.3155G>C
G1052A
2D
AIThe SynGAP1 missense variant G1052A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic outcome, creating a single discordant signal. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence supports a benign classification, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984420Disordered0.892068Binding0.3670.9380.875-6.945Likely Benign0.086Likely BenignLikely Benign0.382Likely Benign-0.14Neutral0.649Possibly Damaging0.287Benign3.93Benign1.00Tolerated0.32590.4949102.214.03
c.3155G>T
G1052V
2D
AIThe SynGAP1 missense variant G1052V is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate benign, while the high‑accuracy AlphaMissense‑Optimized score is benign and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign. In contrast, polyPhen‑2 HumDiv and HumVar both predict pathogenic, and ESM1b remains uncertain. No Foldetta stability assessment is available, so it does not influence the overall interpretation. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984420Disordered0.892068Binding0.3670.9380.875-7.717In-Between0.094Likely BenignLikely Benign0.452Likely Benign-0.12Neutral0.901Possibly Damaging0.619Possibly Damaging3.90Benign0.19Tolerated0.13290.3499-1-34.642.08
c.3157A>C
S1053R
2D
AIThe SynGAP1 missense variant S1053R is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority‑vote SGM‑Consensus also reports a likely benign outcome. In contrast, the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy analyses reinforce the benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is likely benign, with no contradictory Foldetta data. Overall, the preponderance of evidence points to a benign effect for S1053R, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.875-6.421Likely Benign0.359AmbiguousLikely Benign0.225Likely Benign0.43Neutral0.969Probably Damaging0.581Possibly Damaging5.33Benign0.59Tolerated3.7750.13210.3820-10-3.769.11
c.3157A>G
S1053G
2D
AIThe SynGAP1 missense variant S1053G is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions strongly suggests that S1053G is most likely benign, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.875-1.016Likely Benign0.050Likely BenignLikely Benign0.220Likely Benign-0.57Neutral0.001Benign0.002Benign5.32Benign0.59Tolerated0.27240.5046100.4-30.03
c.3157A>T
S1053C
2D
AIThe SynGAP1 missense variant S1053C is catalogued in gnomAD (ID 6‑33443709‑A‑T) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The ESM1b score is uncertain, providing no clear direction. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no reported result for this variant. Overall, the majority of reliable predictors classify S1053C as benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.8756-33443709-A-T-7.574In-Between0.095Likely BenignLikely Benign0.220Likely Benign-0.61Neutral0.977Probably Damaging0.777Possibly Damaging5.30Benign0.11Tolerated3.7750.16750.5895-103.316.06
c.3158G>A
S1053N
2D
AIThe SynGAP1 missense variant S1053N is reported in gnomAD (variant ID 6‑33443710‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts it as pathogenic, while the consensus score from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus also indicates a likely benign outcome. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.8756-33443710-G-A16.21e-7-6.282Likely Benign0.120Likely BenignLikely Benign0.208Likely Benign-0.54Neutral0.625Possibly Damaging0.193Benign5.30Benign0.34Tolerated3.7750.19530.460511-2.727.03
c.3158G>C
S1053T
2D
AIThe SynGAP1 missense variant S1053T is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts it as pathogenic, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the preponderance of evidence points to a benign impact for S1053T, and this conclusion is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.875-6.209Likely Benign0.076Likely BenignLikely Benign0.223Likely Benign-0.25Neutral0.625Possibly Damaging0.249Benign5.32Benign0.70Tolerated0.20550.5976110.114.03
c.3158G>T
S1053I
2D
AIThe SynGAP1 missense variant S1053I is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that S1053I is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.875-6.572Likely Benign0.177Likely BenignLikely Benign0.250Likely Benign-0.46Neutral0.925Possibly Damaging0.413Benign5.32Benign0.10Tolerated0.15360.4780-1-25.326.08
c.3159C>A
S1053R
2D
AIThe SynGAP1 missense variant S1053R is reported in gnomAD (variant ID 6‑33443711‑C‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. Overall, the majority of high‑accuracy predictors and consensus analyses indicate a benign impact. Thus, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.8756-33443711-C-A11.10e-6-6.421Likely Benign0.359AmbiguousLikely Benign0.303Likely Benign0.43Neutral0.969Probably Damaging0.581Possibly Damaging5.33Benign0.59Tolerated3.7750.13210.3820-10-3.769.11
c.3159C>G
S1053R
2D
AIThe SynGAP1 missense variant S1053R is reported in gnomAD (ID 6‑33443711‑C‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and the high‑accuracy consensus methods give a benign verdict: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports “Likely Benign.” Foldetta, a protein‑folding stability predictor combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact. The predictions do not contradict any ClinVar status, as none is currently assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.8756-33443711-C-G-6.421Likely Benign0.359AmbiguousLikely Benign0.304Likely Benign0.43Neutral0.969Probably Damaging0.581Possibly Damaging5.33Benign0.59Tolerated3.7750.13210.3820-10-3.769.11
c.3160G>C
G1054R
2D
AIThe SynGAP1 missense variant G1054R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for G1054R, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.878015Binding0.3890.9360.875-8.863Likely Pathogenic0.326Likely BenignLikely Benign0.234Likely Benign0.29Neutral0.988Probably Damaging0.589Possibly Damaging4.05Benign0.42Tolerated0.11640.4342-3-2-4.199.14
c.3160G>T
G1054C
2D
AIThe SynGAP1 missense variant G1054C is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.878015Binding0.3890.9360.875-9.548Likely Pathogenic0.118Likely BenignLikely Benign0.297Likely Benign-0.59Neutral0.999Probably Damaging0.907Possibly Damaging4.00Benign0.10Tolerated0.14130.4427-3-32.946.09
c.3161G>C
G1054A
2D
AIThe SynGAP1 missense variant G1054A is catalogued in gnomAD (ID 6‑33443713‑G‑C) but has no ClinVar entry. Across a broad panel of in‑silico predictors, every tool reports a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity, so the pathogenic‑prediction group is empty. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no reported result for this variant, so its status is unavailable. Based on the unanimous benign predictions and the lack of any ClinVar pathogenic classification, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.878015Binding0.3890.9360.8756-33443713-G-C-6.786Likely Benign0.078Likely BenignLikely Benign0.243Likely Benign-0.05Neutral0.288Benign0.071Benign4.03Benign1.00Tolerated3.7750.33050.5144012.214.03
c.3161G>T
G1054V
2D
AIThe SynGAP1 missense variant G1054V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as likely benign. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts benign and the SGM‑Consensus also reports likely benign; Foldetta results are unavailable. Overall, the consensus of the available predictions points to a benign impact, and this is consistent with the lack of ClinVar evidence; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.878015Binding0.3890.9360.875-6.994Likely Benign0.110Likely BenignLikely Benign0.171Likely Benign-0.22Neutral0.818Possibly Damaging0.221Benign4.01Benign0.18Tolerated0.15780.3694-1-34.642.08
c.3163G>A
G1055R
2D
AIThe SynGAP1 missense variant G1055R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors benign, while Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.982235Disordered0.872113Binding0.3790.9350.875-8.778Likely Pathogenic0.375AmbiguousLikely Benign0.275Likely Benign-0.09Neutral0.970Probably Damaging0.728Possibly Damaging3.31Benign0.08Tolerated0.10130.4733-3-2-4.199.14
c.3163G>C
G1055R
2D
AIThe SynGAP1 missense variant G1055R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. AlphaMissense‑Default is uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign outcome (2 benign vs. 1 pathogenic, 1 uncertain). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence indicates the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.982235Disordered0.872113Binding0.3790.9350.875-8.778Likely Pathogenic0.375AmbiguousLikely Benign0.275Likely Benign-0.09Neutral0.970Probably Damaging0.728Possibly Damaging3.31Benign0.08Tolerated0.10130.4733-3-2-4.199.14
c.3163G>T
G1055W
2D
AIThe SynGAP1 missense variant G1055W is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar status, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.872113Binding0.3790.9350.875-11.436Likely Pathogenic0.317Likely BenignLikely Benign0.367Likely Benign-0.77Neutral0.997Probably Damaging0.946Probably Damaging3.28Benign0.01Affected0.08990.4246-7-2-0.5129.16
c.3164G>A
G1055E
2D
AIThe SynGAP1 missense variant G1055E is catalogued in gnomAD (variant ID 6‑33443716‑G‑A) but has no ClinVar entry. In silico prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a benign effect. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.872113Binding0.3790.9350.8756-33443716-G-A16.21e-7-10.951Likely Pathogenic0.290Likely BenignLikely Benign0.320Likely Benign-0.03Neutral0.901Possibly Damaging0.456Possibly Damaging3.30Benign0.10Tolerated3.7750.15250.4459-20-3.172.06
c.3164G>C
G1055A
2D
AIThe SynGAP1 missense variant G1055A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only polyPhen‑2 HumDiv indicates a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign and the SGM‑Consensus also reports Likely Benign; Foldetta results are unavailable. Overall, the consensus of the available predictions points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.872113Binding0.3790.9350.875-6.835Likely Benign0.083Likely BenignLikely Benign0.244Likely Benign0.15Neutral0.649Possibly Damaging0.148Benign3.30Benign1.00Tolerated0.33500.5144102.214.03
c.3164G>T
G1055V
2D
AIThe SynGAP1 missense variant G1055V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while ESM1b remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.872113Binding0.3790.9350.875-7.434In-Between0.114Likely BenignLikely Benign0.399Likely Benign0.26Neutral0.818Possibly Damaging0.222Benign3.28Benign0.17Tolerated0.13990.3694-1-34.642.08
c.3166G>A
G1056S
2D
AIThe SynGAP1 missense variant G1056S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.868632Binding0.4020.9350.875-5.252Likely Benign0.080Likely BenignLikely Benign0.339Likely Benign-0.28Neutral0.451Benign0.149Benign1.87Pathogenic0.55Tolerated0.24970.570210-0.430.03
c.3166G>C
G1056R
2D
AIThe SynGAP1 missense variant G1056R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are ESM1b and FATHMM, while AlphaMissense‑Default remains uncertain. High‑accuracy assessment shows AlphaMissense‑Optimized as benign, the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) favors a pathogenic outcome, and Foldetta data are unavailable. Overall, the majority of conventional predictors indicate a benign impact, whereas the SGM Consensus suggests pathogenicity. Given the preponderance of benign predictions and the lack of ClinVar evidence, the variant is most likely benign, and this assessment does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988291Disordered0.868632Binding0.4020.9350.875-9.358Likely Pathogenic0.390AmbiguousLikely Benign0.410Likely Benign0.12Neutral0.011Benign0.010Benign1.83Pathogenic0.13Tolerated0.11270.4533-3-2-4.199.14
c.3166G>T
G1056C
2D
AIThe SynGAP1 missense variant G1056C is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 benign vs 2 pathogenic), and Foldetta results are unavailable. Overall, the balance of evidence leans toward a benign impact. This conclusion does not contradict ClinVar status, as the variant has no ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988291Disordered0.868632Binding0.4020.9350.875-9.974Likely Pathogenic0.122Likely BenignLikely Benign0.432Likely Benign-0.70Neutral0.994Probably Damaging0.777Possibly Damaging1.83Pathogenic0.06Tolerated0.14140.4439-3-32.946.09
c.3167G>A
G1056D
2D
AIThe SynGAP1 missense variant G1056D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, ESM1b, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (2 benign vs. 2 pathogenic), and Foldetta results are unavailable. Overall, the majority of evidence (six benign vs. three pathogenic) supports a benign classification. This conclusion does not contradict ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988291Disordered0.868632Binding0.4020.9350.875-10.352Likely Pathogenic0.328Likely BenignLikely Benign0.380Likely Benign0.09Neutral0.666Possibly Damaging0.193Benign1.83Pathogenic0.92Tolerated0.19120.26261-1-3.158.04
c.3167G>C
G1056A
2D
AIThe SynGAP1 missense variant G1056A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while ESM1b remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign consensus (2 benign vs. 1 pathogenic, with one uncertain). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988291Disordered0.868632Binding0.4020.9350.875-7.458In-Between0.086Likely BenignLikely Benign0.325Likely Benign-0.25Neutral0.264Benign0.097Benign1.85Pathogenic0.49Tolerated0.33250.4957102.214.03
c.3167G>T
G1056V
2D
AIThe SynGAP1 missense variant G1056V is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are ESM1b and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (2 benign vs 2 pathogenic), and Foldetta results are unavailable. Overall, the majority of evidence (7 benign vs 2 pathogenic) supports a benign classification. This consensus does not contradict ClinVar status, which has no entry for this variant. Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988291Disordered0.868632Binding0.4020.9350.875-8.130Likely Pathogenic0.097Likely BenignLikely Benign0.448Likely Benign-0.24Neutral0.292Benign0.110Benign1.83Pathogenic0.08Tolerated0.14880.3507-1-34.642.08
c.3169A>C
S1057R
2D
AIThe SynGAP1 missense variant S1057R is catalogued in gnomAD (ID 6‑33443721‑A‑C) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.8756-33443721-A-C-6.648Likely Benign0.379AmbiguousLikely Benign0.221Likely Benign-0.24Neutral0.677Possibly Damaging0.168Benign5.30Benign0.21Tolerated3.7750.15840.3620-10-3.769.11
c.3169A>G
S1057G
2D
AIThe SynGAP1 missense variant S1057G is reported in gnomAD (ID 6‑33443721‑A‑G) but has no ClinVar entry. All evaluated in‑silico predictors uniformly classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. The high‑accuracy consensus methods likewise support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are unavailable. Consequently, the variant is most likely benign based on current predictions, and this assessment does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.8756-33443721-A-G17.20e-7-1.005Likely Benign0.049Likely BenignLikely Benign0.211Likely Benign-0.47Neutral0.421Benign0.111Benign5.76Benign0.52Tolerated3.7750.26540.4846010.4-30.03
c.3169A>T
S1057C
2D
AIThe SynGAP1 missense variant S1057C is reported in gnomAD (ID 6‑33443721‑A‑T) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Two tools, polyPhen‑2 HumDiv and polyPhen‑2 HumVar, predict a pathogenic impact, while ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar classification (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.8756-33443721-A-T-7.529In-Between0.100Likely BenignLikely Benign0.258Likely Benign-0.64Neutral0.977Probably Damaging0.683Possibly Damaging5.23Benign0.10Tolerated3.7750.18560.6106-103.316.06
c.316A>G
R106G
2D
AIThe SynGAP1 missense variant R106G is listed in gnomAD (ID 6‑33432181‑A‑G) but has no ClinVar entry. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. Those that predict a pathogenic effect are SIFT and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, SGM‑Consensus as likely benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. There is no ClinVar classification to contradict this assessment. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.663409Binding0.3450.8620.8756-33432181-A-G16.20e-7-2.617Likely Benign0.835Likely PathogenicAmbiguous0.161Likely Benign-2.21Neutral0.421Benign0.050Benign3.65Benign0.00Affected4.0530.36800.3980-2-34.1-99.14
c.316A>T
R106W
2D
AIThe SynGAP1 missense variant R106W is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and FATHMM, while those that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain. High‑accuracy assessments are inconclusive: AlphaMissense‑Optimized is uncertain, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is a 2‑vs‑2 tie, and Foldetta results are unavailable. Overall, more tools predict pathogenicity (5) than benign (3), and no ClinVar evidence contradicts this assessment. Thus, the variant is most likely pathogenic based on the available predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.675549Disordered0.663409Binding0.3450.8620.875-5.350Likely Benign0.875Likely PathogenicAmbiguous0.240Likely Benign-3.31Deleterious0.983Probably Damaging0.624Possibly Damaging3.62Benign0.00Affected0.13690.39952-33.630.03
c.3170G>C
S1057T
2D
AIThe SynGAP1 missense variant S1057T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods indicates that the variant is most likely benign, and this assessment is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.875-6.375Likely Benign0.079Likely BenignLikely Benign0.241Likely Benign-0.18Neutral0.625Possibly Damaging0.170Benign5.26Benign0.60Tolerated0.22890.5976110.114.03
c.3170G>T
S1057I
2D
AIThe SynGAP1 missense variant S1057I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to the variant being most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.875-6.887Likely Benign0.186Likely BenignLikely Benign0.259Likely Benign-0.87Neutral0.925Possibly Damaging0.238Benign5.24Benign0.07Tolerated0.18020.4980-1-25.326.08
c.3171C>A
S1057R
2D
AIThe SynGAP1 missense variant S1057R is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign. Only polyPhen‑2 HumDiv flags it as pathogenic, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.875-6.648Likely Benign0.379AmbiguousLikely Benign0.272Likely Benign-0.24Neutral0.677Possibly Damaging0.168Benign5.30Benign0.21Tolerated3.7750.15840.3620-10-3.769.11
c.3171C>G
S1057R
2D
AIThe SynGAP1 missense variant S1057R is catalogued in gnomAD (ID 6‑33443723‑C‑G) but has no ClinVar submission. Functional prediction tools largely converge on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all report benign or tolerated. Only polyPhen‑2 HumDiv flags it as pathogenic, while AlphaMissense‑Default remains uncertain. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus confirms a benign likelihood; Foldetta data are unavailable, so no stability evidence is provided. Taken together, the preponderance of evidence indicates the variant is most likely benign, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.8756-33443723-C-G-6.648Likely Benign0.379AmbiguousLikely Benign0.272Likely Benign-0.24Neutral0.677Possibly Damaging0.168Benign5.30Benign0.21Tolerated3.7750.15840.3620-10-3.769.11
c.3172G>C
G1058R
2D
AIThe SynGAP1 missense variant G1058R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only two predictors—SIFT and ESM1b—suggest a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign consensus. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not conflict with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.980739Disordered0.885724Binding0.4070.9290.875-8.967Likely Pathogenic0.339Likely BenignLikely Benign0.138Likely Benign0.34Neutral0.174Benign0.140Benign5.29Benign0.00Affected0.11450.4342-3-2-4.199.14
c.3172G>T
G1058C
2D
AIThe SynGAP1 missense variant G1058C is reported in gnomAD (ID 6‑33443724‑G‑T) but has no ClinVar entry. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are polyPhen‑2 HumDiv, SIFT, and ESM1b. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of computational evidence points to a benign effect, and this is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.980739Disordered0.885724Binding0.4070.9290.8756-33443724-G-T16.21e-7-9.384Likely Pathogenic0.132Likely BenignLikely Benign0.264Likely Benign-0.19Neutral0.600Possibly Damaging0.433Benign5.19Benign0.01Affected3.7750.14560.4627-3-32.946.09
c.3173G>A
G1058D
2D
AIThe SynGAP1 missense variant G1058D is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33443725‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict ClinVar, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.980739Disordered0.885724Binding0.4070.9290.8756-33443725-G-A16.21e-7-10.344Likely Pathogenic0.391AmbiguousLikely Benign0.177Likely Benign-0.33Neutral0.077Benign0.042Benign5.20Benign0.01Affected3.7750.18890.2435-11-3.158.04
c.3173G>C
G1058A
2D
AIThe SynGAP1 missense variant G1058A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.980739Disordered0.885724Binding0.4070.9290.875-6.823Likely Benign0.082Likely BenignLikely Benign0.159Likely Benign0.21Neutral0.000Benign0.002Benign5.29Benign0.55Tolerated0.32880.5144102.214.03
c.3173G>T
G1058V
2D
AIThe SynGAP1 missense variant G1058V is reported in gnomAD (variant ID 6‑33443725‑G‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.980739Disordered0.885724Binding0.4070.9290.8756-33443725-G-T16.21e-7-6.877Likely Benign0.114Likely BenignLikely Benign0.152Likely Benign-0.12Neutral0.000Benign0.001Benign5.22Benign0.01Affected3.7750.15610.3694-3-14.642.08
c.3175G>C
G1059R
2D
AIThe SynGAP1 missense variant G1059R is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in silico predictors shows a predominance of benign calls: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized all predict a benign effect, whereas SIFT and ESM1b predict pathogenicity; AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce this trend: AlphaMissense‑Optimized is benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also returns a benign prediction. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the balance of evidence points to a benign impact for G1059R, and this conclusion is consistent with the absence of any ClinVar annotation or gnomAD observation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.983019Disordered0.898939Binding0.3990.9260.875-8.452Likely Pathogenic0.376AmbiguousLikely Benign0.333Likely Benign-0.55Neutral0.001Benign0.001Benign2.53Benign0.00Affected4.3220.10520.4342-3-2-4.199.14
c.3175G>T
G1059W
2D
AIThe SynGAP1 missense variant G1059W is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.898939Binding0.3990.9260.875-11.549Likely Pathogenic0.312Likely BenignLikely Benign0.446Likely Benign-1.18Neutral0.983Probably Damaging0.813Possibly Damaging2.53Benign0.00Affected0.09250.4046-7-2-0.5129.16
c.3176G>A
G1059E
2D
AIThe SynGAP1 missense variant G1059E is reported in gnomAD (variant ID 6‑33443728‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only two tools—SIFT and ESM1b—predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.898939Binding0.3990.9260.8756-33443728-G-A16.22e-7-10.459Likely Pathogenic0.297Likely BenignLikely Benign0.390Likely Benign-0.71Neutral0.126Benign0.066Benign2.53Benign0.00Affected4.3220.14640.4069-20-3.172.06
c.3176G>T
G1059V
2D
AIThe SynGAP1 missense variant G1059V is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in silico predictors indicates a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score benign, while the majority‑vote SGM‑Consensus also classifies it as likely benign. Only SIFT predicts a pathogenic outcome, and ESM1b remains uncertain. High‑accuracy tools corroborate the benign prediction: AlphaMissense‑Optimized is benign and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is likely benign; Foldetta results are not available. Overall, the preponderance of evidence supports a benign classification for G1059V, and this assessment does not conflict with ClinVar, which currently contains no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.898939Binding0.3990.9260.875-7.242In-Between0.106Likely BenignLikely Benign0.478Likely Benign-0.82Neutral0.259Benign0.066Benign2.54Benign0.00Affected0.14620.3494-1-34.642.08
c.3178G>C
G1060R
2D
AIThe SynGAP1 missense variant G1060R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for G1060R, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979242Disordered0.913048Binding0.4070.9280.875-8.225Likely Pathogenic0.323Likely BenignLikely Benign0.362Likely Benign-0.29Neutral0.971Probably Damaging0.580Possibly Damaging2.63Benign0.17Tolerated0.10380.4342-3-2-4.199.14
c.3178G>T
G1060C
2D
AIThe SynGAP1 missense variant G1060C is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for G1060C, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979242Disordered0.913048Binding0.4070.9280.875-9.630Likely Pathogenic0.116Likely BenignLikely Benign0.363Likely Benign-0.60Neutral0.999Probably Damaging0.917Probably Damaging2.63Benign0.12Tolerated0.13400.4227-3-32.946.09
c.3179G>A
G1060D
2D
AIThe SynGAP1 missense variant G1060D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also leans benign (2 benign vs 1 pathogenic). Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.979242Disordered0.913048Binding0.4070.9280.875-9.824Likely Pathogenic0.342AmbiguousLikely Benign0.391Likely Benign-0.58Neutral0.905Possibly Damaging0.538Possibly Damaging2.63Benign0.20Tolerated0.17030.20351-1-3.158.04
c.3179G>C
G1060A
2D
AIThe SynGAP1 missense variant G1060A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic outcome, creating a single discordant signal. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979242Disordered0.913048Binding0.4070.9280.875-6.539Likely Benign0.082Likely BenignLikely Benign0.341Likely Benign0.30Neutral0.664Possibly Damaging0.283Benign2.69Benign0.98Tolerated0.33350.4944102.214.03
c.317G>A
R106K
2D
AIThe SynGAP1 missense variant R106K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus indicates Likely Benign, and Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign effect for R106K, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.663409Binding0.3450.8620.875-4.312Likely Benign0.513AmbiguousLikely Benign0.150Likely Benign-1.25Neutral0.004Benign0.001Benign3.82Benign0.00Affected0.56020.4129Weaken320.6-28.01
c.317G>C
R106T
2D
AIThe SynGAP1 missense variant R106T is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain, and no Foldetta stability assessment is available. Separately, the high‑accuracy consensus (SGM‑Consensus) classifies the variant as Likely Benign, while AlphaMissense‑Optimized remains uncertain and Foldetta data are missing. Based on the overall pattern of predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.663409Binding0.3450.8620.875-4.197Likely Benign0.950Likely PathogenicAmbiguous0.229Likely Benign-2.30Neutral0.004Benign0.002Benign3.67Benign0.00Affected0.19410.4742-1-13.8-55.08
c.317G>T
R106M
2D
AIThe SynGAP1 missense variant R106M is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumVar, ESM1b, and FATHMM. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy methods give the following results: AlphaMissense‑Optimized predicts pathogenic; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (2 vs 2), and Foldetta data are unavailable. Because the majority of tools (five of nine) predict pathogenicity and the most accurate predictor (AlphaMissense‑Optimized) also indicates pathogenicity, the variant is most likely pathogenic. This assessment does not contradict ClinVar status, as the variant has not yet been reported there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.675549Disordered0.663409Binding0.3450.8620.875-4.804Likely Benign0.967Likely PathogenicLikely Pathogenic0.184Likely Benign-2.65Deleterious0.940Possibly Damaging0.360Benign3.64Benign0.00Affected0.19710.41460-16.4-24.99
c.3181G>C
G1061R
2D
AIThe SynGAP1 missense variant G1061R is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while ESM1b and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because it contains two benign and two uncertain calls, and Foldetta results are unavailable. Overall, the balance of evidence favors a benign classification. This conclusion does not contradict ClinVar status, as the variant has not been reported there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.978672Disordered0.926729Binding0.3940.9230.875-7.721In-Between0.343AmbiguousLikely Benign0.315Likely Benign-0.17Neutral0.411Benign0.132Benign3.99Benign0.00Affected0.10370.4332-3-2-4.199.14
c.3182G>A
G1061D
2D
AIThe SynGAP1 missense variant G1061D is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign prediction (2 benign vs. 1 pathogenic, 1 uncertain). Foldetta results are unavailable. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.978672Disordered0.926729Binding0.3940.9230.875-9.481Likely Pathogenic0.346AmbiguousLikely Benign0.375Likely Benign-1.32Neutral0.224Benign0.120Benign4.01Benign0.00Affected0.16710.20241-1-3.158.04
c.3182G>C
G1061A
2D
AIThe SynGAP1 missense variant G1061A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.926729Binding0.3940.9230.875-6.328Likely Benign0.082Likely BenignLikely Benign0.244Likely Benign-0.34Neutral0.004Benign0.002Benign4.01Benign0.00Affected0.32890.5133102.214.03
c.3182G>T
G1061V
2D
AIThe SynGAP1 missense variant G1061V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign. Foldetta results are unavailable. Overall, the majority of evidence indicates that G1061V is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.926729Binding0.3940.9230.875-6.709Likely Benign0.106Likely BenignLikely Benign0.307Likely Benign-1.41Neutral0.224Benign0.066Benign3.98Benign0.00Affected0.14310.3684-1-34.642.08
c.3184G>C
G1062R
2D
AIThe SynGAP1 missense variant G1062R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicating a likely benign outcome, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.936972Binding0.3680.9170.875-6.933Likely Benign0.353AmbiguousLikely Benign0.413Likely Benign-0.34Neutral0.797Possibly Damaging0.139Benign4.10Benign0.01Affected4.3220.10130.4342-3-2-4.199.14
c.3184G>T
G1062W
2D
AIThe SynGAP1 missense variant G1062W is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which labels the variant as “Likely Benign.” Pathogenic predictions come from polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b, all of which classify the change as damaging. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.936972Binding0.3680.9170.875-9.667Likely Pathogenic0.315Likely BenignLikely Benign0.401Likely Benign-1.38Neutral0.993Probably Damaging0.890Possibly Damaging4.09Benign0.00Affected0.09080.4246-7-2-0.5129.16
c.3185G>A
G1062E
2D
AIThe SynGAP1 missense variant G1062E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.936972Binding0.3680.9170.875-8.185Likely Pathogenic0.272Likely BenignLikely Benign0.383Likely Benign-1.02Neutral0.126Benign0.041Benign4.10Benign0.01Affected0.14900.40690-2-3.172.06
c.3185G>C
G1062A
2D
AIThe SynGAP1 missense variant G1062A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is benign, and this conclusion does not contradict any ClinVar annotation (none present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.936972Binding0.3680.9170.875-6.124Likely Benign0.079Likely BenignLikely Benign0.350Likely Benign0.20Neutral0.059Benign0.028Benign4.20Benign0.51Tolerated0.33050.5144102.214.03
c.3185G>T
G1062V
2D
AIThe SynGAP1 missense variant G1062V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.936972Binding0.3680.9170.875-6.598Likely Benign0.103Likely BenignLikely Benign0.377Likely Benign-0.78Neutral0.259Benign0.066Benign4.12Benign0.01Affected0.14410.3694-1-34.642.08
c.3187G>A
G1063S
2D
AIThe SynGAP1 missense variant G1063S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign. Foldetta results are unavailable, so they do not influence the overall assessment. Consequently, the variant is most likely benign based on the collective predictions, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975134Disordered0.945784Binding0.3940.9130.875-4.707Likely Benign0.067Likely BenignLikely Benign0.052Likely Benign0.20Neutral0.004Benign0.003Benign4.33Benign0.09Tolerated0.24910.570210-0.430.03
c.3187G>C
G1063R
2D
AIThe SynGAP1 missense variant G1063R is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the collective evidence strongly supports a benign classification, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975134Disordered0.945784Binding0.3940.9130.875-5.711Likely Benign0.391AmbiguousLikely Benign0.078Likely Benign0.55Neutral0.411Benign0.114Benign4.28Benign0.09Tolerated0.10370.5133-3-2-4.199.14
c.3187G>T
G1063C
2D
AIThe SynGAP1 missense variant G1063C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which itself is “Likely Benign”). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present). Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975134Disordered0.945784Binding0.3940.9130.875-8.315Likely Pathogenic0.106Likely BenignLikely Benign0.075Likely Benign-1.07Neutral0.938Possibly Damaging0.477Possibly Damaging4.19Benign0.01Affected0.14400.4639-3-32.946.09
c.3188G>A
G1063D
2D
AIThe SynGAP1 missense variant G1063D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is likely benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the computational evidence overwhelmingly supports a benign impact for G1063D, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975134Disordered0.945784Binding0.3940.9130.875-6.950Likely Benign0.367AmbiguousLikely Benign0.057Likely Benign-0.30Neutral0.411Benign0.058Benign4.24Benign0.08Tolerated0.18780.30261-1-3.158.04
c.3188G>C
G1063A
2D
AIThe SynGAP1 missense variant G1063A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975134Disordered0.945784Binding0.3940.9130.875-5.373Likely Benign0.079Likely BenignLikely Benign0.045Likely Benign0.33Neutral0.000Benign0.002Benign4.30Benign0.12Tolerated0.33480.4957102.214.03
c.3188G>T
G1063V
2D
AIThe SynGAP1 missense variant G1063V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority of the high‑accuracy tools) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from multiple prediction algorithms and high‑accuracy tools indicates that G1063V is most likely benign, with no ClinVar status to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975134Disordered0.945784Binding0.3940.9130.875-6.228Likely Benign0.083Likely BenignLikely Benign0.045Likely Benign-0.82Neutral0.004Benign0.002Benign4.29Benign0.03Affected0.14340.3707-1-34.642.08
c.318G>C
R106S
2D
AIThe SynGAP1 missense variant R106S is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Tools that predict a pathogenic effect are SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic, SGM‑Consensus as benign, and the Foldetta stability analysis is unavailable. Overall, the majority of predictions lean toward a benign impact, but the high‑accuracy tools provide conflicting evidence. Thus, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.663409Binding0.3450.8620.875-2.651Likely Benign0.961Likely PathogenicLikely Pathogenic0.093Likely Benign-1.87Neutral0.131Benign0.026Benign3.68Benign0.00Affected0.30500.41290-13.7-69.11
c.318G>T
R106S
2D
AIThe SynGAP1 missense variant R106S is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Tools that predict a pathogenic effect are SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic, SGM‑Consensus as benign, and the Foldetta stability analysis is unavailable. Overall, the majority of predictions lean toward a benign impact, but the high‑accuracy tools provide conflicting evidence. Thus, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.663409Binding0.3450.8620.875-2.651Likely Benign0.961Likely PathogenicLikely Pathogenic0.093Likely Benign-1.87Neutral0.131Benign0.026Benign3.68Benign0.00Affected0.30500.41290-13.7-69.11
c.3190C>A
Q1064K
2D
AIThe SynGAP1 missense variant Q1064K is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective predictions strongly support a benign classification, and this conclusion is consistent with the lack of any ClinVar pathogenic annotation, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875-3.592Likely Benign0.234Likely BenignLikely Benign0.088Likely Benign-0.32Neutral0.224Benign0.120Benign4.23Benign0.24Tolerated0.27580.419211-0.40.04
c.3190C>G
Q1064E
2D
AIThe SynGAP1 missense variant Q1064E is not reported in ClinVar and is absent from gnomAD. All available in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are not available. Based on the unanimous benign predictions and lack of ClinVar evidence, the variant is most likely benign and does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875-4.277Likely Benign0.184Likely BenignLikely Benign0.075Likely Benign-0.48Neutral0.203Benign0.077Benign4.22Benign0.32Tolerated0.22590.2843220.00.98
c.3191A>C
Q1064P
2D
AIThe SynGAP1 missense variant Q1064P is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875-2.032Likely Benign0.058Likely BenignLikely Benign0.270Likely Benign0.93Neutral0.001Benign0.001Benign4.23Benign0.20Tolerated0.28190.47660-11.9-31.01
c.3191A>G
Q1064R
2D
AIThe SynGAP1 missense variant Q1064R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and there is no conflict with ClinVar status because the variant is not yet classified there. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875-2.981Likely Benign0.202Likely BenignLikely Benign0.143Likely Benign-0.28Neutral0.586Possibly Damaging0.159Benign4.19Benign0.16Tolerated0.22570.365411-1.028.06
c.3191A>T
Q1064L
2D
AIThe SynGAP1 missense variant Q1064L is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, is not available for this variant. Overall, the consensus of all available predictions strongly supports a benign classification, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875-3.492Likely Benign0.099Likely BenignLikely Benign0.133Likely Benign-1.16Neutral0.224Benign0.091Benign4.20Benign0.13Tolerated0.18170.5485-2-27.3-14.97
c.3192G>T
Q1064H
2D
AIThe SynGAP1 missense variant Q1064H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for Q1064H, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875-4.576Likely Benign0.162Likely BenignLikely Benign0.063Likely Benign-0.66Neutral0.938Possibly Damaging0.596Possibly Damaging4.15Benign0.05Affected0.24670.4243300.39.01
c.3193C>A
P1065T
2D
AIThe SynGAP1 missense variant P1065T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of predictions (six benign vs. four pathogenic) lean toward a benign classification. There is no ClinVar status to contradict this assessment, so the variant is most likely benign based on current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.959518Binding0.4240.9170.875-5.392Likely Benign0.074Likely BenignLikely Benign0.062Likely Benign-1.23Neutral0.770Possibly Damaging0.481Possibly Damaging2.04Pathogenic0.00Affected0.15770.67880-10.93.99
c.3193C>G
P1065A
2D
AIThe SynGAP1 missense variant P1065A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for P1065A, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.959518Binding0.4240.9170.875-4.043Likely Benign0.054Likely BenignLikely Benign0.050Likely Benign-1.85Neutral0.580Possibly Damaging0.184Benign2.19Pathogenic0.00Affected0.31400.57901-13.4-26.04
c.3193C>T
P1065S
2D
AIThe SynGAP1 missense variant P1065S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.959518Binding0.4240.9170.875-5.512Likely Benign0.076Likely BenignLikely Benign0.041Likely Benign-2.07Neutral0.770Possibly Damaging0.255Benign2.06Pathogenic0.00Affected0.31720.60211-10.8-10.04
c.3194C>A
P1065Q
2D
AIThe SynGAP1 missense variant P1065Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.959518Binding0.4240.9170.875-3.928Likely Benign0.074Likely BenignLikely Benign0.026Likely Benign-2.44Neutral0.102Benign0.057Benign2.00Pathogenic0.00Affected0.14870.54780-1-1.931.01
c.3194C>G
P1065R
2D
AIThe SynGAP1 missense variant P1065R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence from multiple independent predictors indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.959518Binding0.4240.9170.875-3.237Likely Benign0.228Likely BenignLikely Benign0.043Likely Benign-2.46Neutral0.102Benign0.052Benign2.00Pathogenic0.00Affected0.14390.43690-2-2.959.07
c.3196C>A
P1066T
2D
AIThe SynGAP1 missense variant P1066T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. Foldetta results are unavailable. Overall, the majority of computational evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.967676Disordered0.968838Binding0.4030.9130.875-5.973Likely Benign0.082Likely BenignLikely Benign0.167Likely Benign-2.61Deleterious0.996Probably Damaging0.928Probably Damaging2.66Benign0.00Affected0.16520.72400-10.93.99
c.3196C>G
P1066A
2D
AIThe SynGAP1 missense variant P1066A is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.967676Disordered0.968838Binding0.4030.9130.875-4.856Likely Benign0.050Likely BenignLikely Benign0.149Likely Benign-2.35Neutral0.972Probably Damaging0.802Possibly Damaging2.78Benign0.00Affected0.32280.60421-13.4-26.04
c.3197C>A
P1066H
2D
AIThe SynGAP1 missense variant P1066H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.967676Disordered0.968838Binding0.4030.9130.875-6.034Likely Benign0.185Likely BenignLikely Benign0.146Likely Benign-2.90Deleterious1.000Probably Damaging0.975Probably Damaging2.61Benign0.00Affected0.19840.58610-2-1.640.02
c.3197C>G
P1066R
2D
AIThe SynGAP1 missense variant P1066R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, tools that predict a pathogenic outcome are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.967676Disordered0.968838Binding0.4030.9130.875-5.154Likely Benign0.292Likely BenignLikely Benign0.176Likely Benign-2.89Deleterious0.992Probably Damaging0.873Possibly Damaging2.63Benign0.00Affected0.15230.47420-2-2.959.07
c.3199C>A
P1067T
2D
AIThe SynGAP1 missense variant P1067T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. In contrast, polyPhen‑2 HumDiv and SIFT predict pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.966441Disordered0.975099Binding0.4590.9070.875-4.898Likely Benign0.084Likely BenignLikely Benign0.062Likely Benign-1.94Neutral0.827Possibly Damaging0.375Benign2.79Benign0.04Affected0.14490.61320-10.93.99
c.3199C>G
P1067A
2D
AIThe SynGAP1 missense variant P1067A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic outcome, representing the sole discordant prediction. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the preponderance of evidence supports a benign classification for P1067A, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.966441Disordered0.975099Binding0.4590.9070.875-4.639Likely Benign0.052Likely BenignLikely Benign0.073Likely Benign-2.05Neutral0.664Possibly Damaging0.283Benign2.87Benign0.07Tolerated0.30970.53221-13.4-26.04
c.3199C>T
P1067S
2D
AIThe SynGAP1 missense variant P1067S is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Based on the collective predictions, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.966441Disordered0.975099Binding0.4590.9070.875-4.673Likely Benign0.073Likely BenignLikely Benign0.079Likely Benign-1.43Neutral0.271Benign0.054Benign2.91Benign0.48Tolerated0.30860.57531-10.8-10.04
c.319A>G
R107G
2D
AIThe SynGAP1 missense variant R107G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM, while those that predict a pathogenic effect are PROVEAN, SIFT, and AlphaMissense‑Default. High‑accuracy assessments are inconclusive: AlphaMissense‑Optimized is uncertain, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is a tie and thus unavailable, and Foldetta stability analysis is missing. Overall, the majority of tools (five benign vs. three pathogenic) suggest a benign impact, but the lack of consensus from the most accurate predictors means the variant’s effect remains uncertain. This assessment does not contradict any ClinVar status, as none is available.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.666105Disordered0.663448Binding0.3310.8630.875-3.486Likely Benign0.948Likely PathogenicAmbiguous0.180Likely Benign-3.15Deleterious0.421Benign0.050Benign2.98Benign0.00Affected0.32800.4000-3-24.1-99.14
c.319A>T
R107W
2D
AIThe SynGAP1 missense variant R107W is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and FATHMM. Tools that predict a pathogenic effect comprise PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (two pathogenic vs two benign), and Foldetta results are unavailable. Overall, the majority of evidence (six pathogenic vs three benign) points to a pathogenic impact. Thus, the variant is most likely pathogenic, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.666105Disordered0.663448Binding0.3310.8630.875-4.963Likely Benign0.965Likely PathogenicLikely Pathogenic0.328Likely Benign-2.99Deleterious0.983Probably Damaging0.624Possibly Damaging2.95Benign0.00Affected0.11460.42282-33.630.03

Found 8751 rows. Show 800 rows per page. Page 6/11 « Previous | Next »