SynGap Missense Server

Table of SynGAP1 Isoform α2 (UniProt Q96PV0-1) Missense Variants.

c.dna Variant SGM Consensus Domain and Structure information: based on WT protein Annotated databases Deep learning-based pathogenicity predictions Folding stability-based pathogenicity predictions Sequence/structure-based pathogenicity predictions Phase Separation Evolutionary/physical properties Molecular Dynamics-based analysis DOI
Domain IUPred2 ANCHOR2 AlphaFold MobiDB PhosphoSitePlus ClinVar gnomAD ESM1b AlphaMissense FoldX Rosetta Foldetta PremPS REVEL PROVEAN PolyPhen-2 HumDiv PolyPhen-2 HumVar FATHMM SIFT PSMutPred PAM Physical SASA Normalized B-factor backbone Normalized B-factor sidechain SynGAP Structural Annotation
Score Prediction Score Prediction pLDDT disorder disorder LTP HTP KL PTM Clinical Status Review Subm. ID Allele count Allele freq. LLR score Prediction Pathogenicity Class Optimized Average ΔΔG Prediction StdDev ΔΔG Prediction ΔΔG Prediction ΔΔG Prediction Score Prediction Score Prediction pph2_prob Prediction pph2_prob Prediction Nervous System Score Prediction Prediction Status Conservation Sequences IP RF SP RF Prediction PAM250 PAM120 Hydropathy Δ MW Δ Average Δ Δ StdDev Δ StdDev Secondary Tertiary bonds Inside out GAP-Ras interface At membrane No effect MD Alert Verdict Description
c.3328A>C
S1110R
2D
AIThe SynGAP1 missense variant S1110R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive due to a 2‑to‑2 split, and Foldetta results are unavailable. Overall, the balance of evidence (six benign versus three pathogenic predictions) indicates that the variant is most likely benign. This conclusion does not contradict ClinVar status, as the variant has no ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.912647Disordered0.934156Binding0.3460.8920.875-5.075Likely Benign0.773Likely PathogenicLikely Benign0.065Likely Benign-2.46Neutral0.144Benign0.042Benign2.31Pathogenic0.01Affected0.10570.35710-1-3.769.11
c.3328A>G
S1110G
2D
AIThe SynGAP1 missense variant S1110G is listed in ClinVar (ID 1722210.0) as benign and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion aligns with the ClinVar benign classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.912647Disordered0.934156Binding0.3460.8920.875Likely Benign 1-4.674Likely Benign0.079Likely BenignLikely Benign0.035Likely Benign-2.26Neutral0.036Benign0.026Benign2.19Pathogenic0.08Tolerated4.3220.25590.4806100.4-30.03
c.3328A>T
S1110C
2D
AIThe SynGAP1 missense variant S1110C is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also resolves to benign (2 benign vs. 1 pathogenic vote). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of evidence—including the high‑accuracy consensus—points to a benign impact. This conclusion is not contradicted by ClinVar, which has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.912647Disordered0.934156Binding0.3460.8920.875-7.250In-Between0.096Likely BenignLikely Benign0.027Likely Benign-2.12Neutral0.898Possibly Damaging0.477Possibly Damaging2.16Pathogenic0.01Affected0.12140.59540-13.316.06
c.3329G>A
S1110N
2D
AIThe SynGAP1 missense variant S1110N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for S1110N, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.912647Disordered0.934156Binding0.3460.8920.875-5.028Likely Benign0.167Likely BenignLikely Benign0.039Likely Benign-1.99Neutral0.144Benign0.078Benign2.20Pathogenic0.01Affected0.15420.471611-2.727.03
c.3329G>C
S1110T
2D
AIThe SynGAP1 missense variant S1110T is not reported in ClinVar (ClinVar ID None) and has no entries in gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Based on the preponderance of benign predictions and the consensus from high‑accuracy tools, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.912647Disordered0.934156Binding0.3460.8920.875-3.989Likely Benign0.079Likely BenignLikely Benign0.032Likely Benign-1.76Neutral0.001Benign0.003Benign2.21Pathogenic0.04Affected0.15810.6224110.114.03
c.3329G>T
S1110I
2D
AIThe SynGAP1 missense variant S1110I is catalogued in gnomAD (ID 6‑33443881‑G‑T) but has no ClinVar submission. Functional prediction tools show a split: six algorithms (REVEL, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized) predict a benign effect, whereas three (PROVEAN, SIFT, FATHMM) predict pathogenicity. High‑accuracy assessments further refine the picture: AlphaMissense‑Optimized classifies the variant as benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (two benign, two pathogenic); Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, has no available result for this residue. Overall, the preponderance of evidence points to a benign impact, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.912647Disordered0.934156Binding0.3460.8920.8756-33443881-G-T-6.124Likely Benign0.198Likely BenignLikely Benign0.038Likely Benign-2.99Deleterious0.007Benign0.003Benign2.17Pathogenic0.01Affected4.3220.12030.4971-2-15.326.08
c.3330C>A
S1110R
2D
AIThe SynGAP1 missense variant S1110R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a 2‑to‑2 split, and Foldetta results are unavailable. Overall, the majority of evidence (six benign vs. three pathogenic predictions) points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.912647Disordered0.934156Binding0.3460.8920.875-5.075Likely Benign0.773Likely PathogenicLikely Benign0.043Likely Benign-2.46Neutral0.144Benign0.042Benign2.31Pathogenic0.01Affected0.10570.35710-1-3.769.11
c.3330C>G
S1110R
2D
AIThe SynGAP1 missense variant S1110R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a 2‑to‑2 split, and Foldetta results are unavailable. Overall, the majority of evidence (six benign vs. three pathogenic predictions) points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.912647Disordered0.934156Binding0.3460.8920.875-5.075Likely Benign0.773Likely PathogenicLikely Benign0.043Likely Benign-2.46Neutral0.144Benign0.042Benign2.31Pathogenic0.01Affected0.10570.35710-1-3.769.11
c.3304G>A
A1102T
2D
AIThe SynGAP1 missense variant A1102T is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443856‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.915074Disordered0.962659Binding0.3880.8590.875Uncertain 16-33443856-G-A117.17e-6-3.540Likely Benign0.070Likely BenignLikely Benign0.044Likely Benign-0.30Neutral0.001Benign0.001Benign2.32Pathogenic0.95Tolerated3.7750.17550.769910-2.530.03
c.3304G>C
A1102P
2D
AIThe SynGAP1 missense variant A1102P is listed in ClinVar (ID 2789225.0) with an “Uncertain” status and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this is consistent with the ClinVar “Uncertain” classification rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.915074Disordered0.962659Binding0.3880.8590.875Uncertain 1-5.120Likely Benign0.077Likely BenignLikely Benign0.118Likely Benign-0.97Neutral0.000Benign0.002Benign2.26Pathogenic0.13Tolerated3.7750.19780.5919-11-3.426.04
c.3304G>T
A1102S
2D
AIThe SynGAP1 missense variant A1102S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign classification, and this conclusion does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.915074Disordered0.962659Binding0.3880.8590.875-2.900Likely Benign0.067Likely BenignLikely Benign0.041Likely Benign0.05Neutral0.019Benign0.032Benign2.57Benign0.59Tolerated0.26660.650111-2.616.00
c.3305C>A
A1102D
2D
AIThe SynGAP1 missense variant A1102D is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently contains no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.915074Disordered0.962659Binding0.3880.8590.875-4.647Likely Benign0.388AmbiguousLikely Benign0.081Likely Benign-1.38Neutral0.033Benign0.028Benign2.27Pathogenic0.12Tolerated0.20450.29840-2-5.344.01
c.3305C>G
A1102G
2D
AIThe SynGAP1 A1102G missense variant is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome. The high‑accuracy consensus (SGM‑Consensus) classifies the variant as “Likely Benign,” and AlphaMissense‑Optimized also reports a benign prediction. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.915074Disordered0.962659Binding0.3880.8590.875-3.070Likely Benign0.078Likely BenignLikely Benign0.060Likely Benign0.39Neutral0.000Benign0.001Benign2.30Pathogenic0.14Tolerated0.19470.495810-2.2-14.03
c.3305C>T
A1102V
2D
AIThe SynGAP1 missense variant A1102V is listed in ClinVar (ID 2846719.0) as Benign and is present in gnomAD (variant ID 6‑33443857‑C‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion aligns with the ClinVar benign classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.915074Disordered0.962659Binding0.3880.8590.875Benign 16-33443857-C-T-2.440Likely Benign0.077Likely BenignLikely Benign0.081Likely Benign-1.27Neutral0.017Benign0.028Benign2.29Pathogenic0.12Tolerated3.7750.13330.6264002.428.05
c.3994A>C
T1332P
2D
AIThe SynGAP1 missense variant T1332P is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and FATHMM, whereas a majority of tools (PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default) predict a pathogenic impact; AlphaMissense‑Optimized is uncertain. High‑accuracy assessments are inconclusive: AlphaMissense‑Optimized is uncertain, the SGM Consensus (a majority vote among AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is tied 2‑2 and thus unavailable, and Foldetta results are not provided. Overall, the balance of evidence favors a pathogenic classification, and this assessment does not contradict any existing ClinVar status because the variant has no ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.915074Disordered0.948427Binding0.4420.7540.875-3.404Likely Benign0.918Likely PathogenicAmbiguous0.238Likely Benign-3.12Deleterious0.994Probably Damaging0.981Probably Damaging2.95Benign0.00Affected0.21850.53080-1-0.9-3.99
c.3994A>G
T1332A
2D
AIThe SynGAP1 missense variant T1332A is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, ESM1b, and FATHMM, whereas those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain. High‑accuracy assessments are inconclusive: AlphaMissense‑Optimized remains uncertain; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is a 2‑vs‑2 tie, and Foldetta results are unavailable. Overall, the majority of available predictions (five pathogenic vs. three benign) indicate a pathogenic impact. This conclusion is not contradicted by ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.915074Disordered0.948427Binding0.4420.7540.875-3.521Likely Benign0.887Likely PathogenicAmbiguous0.150Likely Benign-2.85Deleterious0.953Possibly Damaging0.935Probably Damaging3.02Benign0.00Affected0.40420.4766102.5-30.03
c.3994A>T
T1332S
2D
AIThe SynGAP1 missense variant T1332S is reported in gnomAD (ID 6‑33451868‑A‑T) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as “Likely Benign” (three benign votes versus one pathogenic). High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect; this conclusion is not contradicted by ClinVar, which contains no classification for T1332S.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.915074Disordered0.948427Binding0.4420.7540.8756-33451868-A-T-3.085Likely Benign0.674Likely PathogenicLikely Benign0.163Likely Benign-2.29Neutral0.980Probably Damaging0.935Probably Damaging3.00Benign0.00Affected3.7750.34510.500711-0.1-14.03
c.3995C>A
T1332K
2D
AIThe SynGAP1 missense variant T1332K is catalogued in gnomAD (ID 6‑33451869‑C‑A) but has no ClinVar submission. Functional prediction tools cluster into two groups: benign predictions from REVEL, ESM1b, and FATHMM; pathogenic predictions from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain. A high‑accuracy consensus (SGM) derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN yields a 2‑to‑2 split, leaving the consensus inconclusive. No Foldetta stability assessment is available. Overall, the majority of evidence (five pathogenic versus three benign) points to a pathogenic effect. This conclusion is not contradicted by ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.915074Disordered0.948427Binding0.4420.7540.8756-33451869-C-A-3.264Likely Benign0.935Likely PathogenicAmbiguous0.247Likely Benign-3.48Deleterious0.998Probably Damaging0.989Probably Damaging2.96Benign0.00Affected3.7750.14240.4376-10-3.227.07
c.3995C>G
T1332R
2D
AIThe SynGAP1 missense variant T1332R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and FATHMM, whereas a majority of tools (PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default) predict a pathogenic impact. AlphaMissense‑Optimized is uncertain. High‑accuracy assessments are inconclusive: AlphaMissense‑Optimized remains uncertain; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is a 2‑vs‑2 tie and therefore unavailable; Foldetta results are not provided. Overall, the balance of evidence (five pathogenic versus three benign predictions) indicates that the variant is most likely pathogenic, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.915074Disordered0.948427Binding0.4420.7540.875-3.354Likely Benign0.878Likely PathogenicAmbiguous0.271Likely Benign-3.59Deleterious0.998Probably Damaging0.993Probably Damaging2.96Benign0.00Affected0.11730.3867-1-1-3.855.08
c.3995C>T
T1332M
2D
AISynGAP1 missense variant T1332M is listed as Benign in ClinVar (ID 794425) and is present in gnomAD (6‑33451869‑C‑T). Functional prediction tools show mixed results: benign calls come from REVEL, ESM1b, and FATHMM, while pathogenic calls are made by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. High‑accuracy assessments are inconclusive: AlphaMissense‑Optimized returned an uncertain result, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is a tie, and no Foldetta stability data are available. Overall, the majority of evidence points toward a pathogenic effect, which contradicts the ClinVar benign classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.915074Disordered0.948427Binding0.4420.7540.875Likely Benign 16-33451869-C-T201.86e-5-4.107Likely Benign0.948Likely PathogenicAmbiguous0.252Likely Benign-3.63Deleterious1.000Probably Damaging0.991Probably Damaging2.95Benign0.00Affected3.7750.15510.6513-1-12.630.09
c.4000A>C
N1334H
2D
AIThe SynGAP1 missense variant N1334H is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of reliable tools and the high‑accuracy consensus predict a benign impact. This conclusion is not contradicted by ClinVar, which contains no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.915074Disordered0.960403Binding0.4060.7340.875-4.954Likely Benign0.496AmbiguousLikely Benign0.164Likely Benign-2.99Deleterious0.985Probably Damaging0.927Probably Damaging3.50Benign0.00Affected0.19630.6246210.323.04
c.4000A>G
N1334D
2D
AIThe SynGAP1 missense variant N1334D (ClinVar ID 3653769.0) is listed as Uncertain in ClinVar and is present in gnomAD (ID 6‑33451874‑A‑G). Functional prediction tools show a split: benign calls come from REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic calls come from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. High‑accuracy assessments give a benign result from AlphaMissense‑Optimized, an inconclusive SGM Consensus (a 2‑vs‑2 majority vote among AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN), and no available Foldetta stability data. Overall, the majority of predictions (5/10) indicate pathogenicity, and the high‑accuracy tools do not overturn this trend. Therefore, the variant is most likely pathogenic, which does not contradict its ClinVar status of Uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.915074Disordered0.960403Binding0.4060.7340.875Uncertain 16-33451874-A-G-4.584Likely Benign0.674Likely PathogenicLikely Benign0.126Likely Benign-3.06Deleterious0.886Possibly Damaging0.522Possibly Damaging3.55Benign0.00Affected3.7750.24440.3307120.00.98
c.4000A>T
N1334Y
2D
AIThe SynGAP1 missense variant N1334Y is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized, whereas pathogenic predictions are made by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—yields a tie and is therefore inconclusive; Foldetta results are unavailable. Overall, the majority of conventional tools predict a pathogenic impact, but the single high‑accuracy benign prediction and the inconclusive consensus suggest uncertainty. Consequently, the variant is most likely pathogenic based on the prevailing evidence, and this assessment does not contradict any ClinVar annotation because the variant has not yet been reported there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.915074Disordered0.960403Binding0.4060.7340.875-5.916Likely Benign0.770Likely PathogenicLikely Benign0.249Likely Benign-4.62Deleterious0.985Probably Damaging0.852Possibly Damaging3.49Benign0.00Affected0.07160.5447-2-22.249.07
c.4001A>C
N1334T
2D
AIThe SynGAP1 missense variant N1334T is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (a majority vote among AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (two pathogenic vs. two benign votes). Foldetta, which evaluates protein‑folding stability, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and there is no ClinVar entry to contradict this assessment. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.915074Disordered0.960403Binding0.4060.7340.875-4.249Likely Benign0.576Likely PathogenicLikely Benign0.103Likely Benign-3.45Deleterious0.047Benign0.063Benign3.59Benign0.00Affected0.16000.5519002.8-13.00
c.4001A>G
N1334S
2D
AIThe SynGAP1 missense variant N1334S is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and SIFT. AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields a benign consensus (2 benign vs. 1 pathogenic, 1 uncertain). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.915074Disordered0.960403Binding0.4060.7340.875-3.989Likely Benign0.409AmbiguousLikely Benign0.107Likely Benign-2.94Deleterious0.557Possibly Damaging0.348Benign3.56Benign0.00Affected0.35420.4708112.7-27.03
c.4001A>T
N1334I
2D
AIThe SynGAP1 missense variant N1334I is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and FATHMM, whereas those that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (2 pathogenic vs. 2 benign), and Foldetta results are unavailable. Overall, the balance of evidence (seven pathogenic vs. three benign predictions) indicates that the variant is most likely pathogenic. This conclusion is not contradicted by ClinVar status, as the variant has no existing ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.915074Disordered0.960403Binding0.4060.7340.875-5.880Likely Benign0.962Likely PathogenicLikely Pathogenic0.193Likely Benign-5.06Deleterious0.985Probably Damaging0.721Possibly Damaging3.50Benign0.00Affected0.08610.5491-2-38.0-0.94
c.4002C>A
N1334K
2D
AIThe SynGAP1 missense variant N1334K is listed in gnomAD (ID 6‑33451876‑C‑A) but has no ClinVar record. Functional prediction tools cluster into two groups: benign predictions come from REVEL, ESM1b, and FATHMM, while pathogenic predictions arise from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain. The high‑accuracy consensus (SGM Consensus) derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN is inconclusive (2 pathogenic vs 2 benign). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, more tools (five) predict pathogenicity than benign (three), and the high‑accuracy methods do not overturn this trend. Therefore, the variant is most likely pathogenic, and this assessment does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.915074Disordered0.960403Binding0.4060.7340.8756-33451876-C-A-4.875Likely Benign0.934Likely PathogenicAmbiguous0.109Likely Benign-3.49Deleterious0.979Probably Damaging0.756Possibly Damaging3.54Benign0.00Affected3.7750.23550.516301-0.414.07
c.4002C>G
N1334K
2D
AIThe SynGAP1 missense variant N1334K is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, ESM1b, and FATHMM, whereas pathogenic predictions arise from PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain. High‑accuracy assessments are limited: AlphaMissense‑Optimized remains inconclusive; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is a 2‑to‑2 tie and therefore unavailable; Foldetta predictions are not provided. Overall, the balance of evidence favors a pathogenic effect for N1334K. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical databases.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.915074Disordered0.960403Binding0.4060.7340.875-4.875Likely Benign0.934Likely PathogenicAmbiguous0.120Likely Benign-3.49Deleterious0.979Probably Damaging0.756Possibly Damaging3.54Benign0.00Affected3.7750.23550.516301-0.414.07
c.2203A>C
S735R
2D
AIThe SynGAP1 missense variant S735R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, while the SGM‑Consensus (majority vote) remains Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. The variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.916840Disordered0.412174Uncertain0.2900.7520.875-6.318Likely Benign0.784Likely PathogenicAmbiguous0.126Likely Benign-1.25Neutral0.997Probably Damaging0.933Probably Damaging2.66Benign0.72Tolerated0.09130.28610-1-3.769.11
c.2203A>G
S735G
2D
AIThe SynGAP1 missense variant S735G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Based on the majority of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.916840Disordered0.412174Uncertain0.2900.7520.875-5.986Likely Benign0.083Likely BenignLikely Benign0.097Likely Benign-0.55Neutral0.953Possibly Damaging0.744Possibly Damaging2.68Benign0.23Tolerated0.27770.4089100.4-30.03
c.2203A>T
S735C
2D
AIThe SynGAP1 missense variant S735C is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. ESM1b is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for S735C, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.916840Disordered0.412174Uncertain0.2900.7520.875-7.291In-Between0.102Likely BenignLikely Benign0.174Likely Benign-2.22Neutral1.000Probably Damaging0.983Probably Damaging2.60Benign0.05Affected0.11360.54640-13.316.06
c.2204G>A
S735N
2D
AIThe SynGAP1 missense variant S735N is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.916840Disordered0.412174Uncertain0.2900.7520.875-6.697Likely Benign0.142Likely BenignLikely Benign0.068Likely Benign-0.68Neutral0.400Benign0.138Benign2.65Benign0.18Tolerated0.13750.382711-2.727.03
c.2204G>C
S735T
2D
AIThe SynGAP1 missense variant S735T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.916840Disordered0.412174Uncertain0.2900.7520.875-5.340Likely Benign0.082Likely BenignLikely Benign0.118Likely Benign-1.03Neutral0.980Probably Damaging0.799Possibly Damaging2.67Benign0.46Tolerated0.14640.5321110.114.03
c.2204G>T
S735I
2D
AIThe SynGAP1 missense variant S735I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for S735I, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.916840Disordered0.412174Uncertain0.2900.7520.875-5.669Likely Benign0.167Likely BenignLikely Benign0.117Likely Benign-1.71Neutral0.999Probably Damaging0.977Probably Damaging2.64Benign0.09Tolerated0.09330.5069-1-25.326.08
c.2205C>A
S735R
2D
AIThe SynGAP1 missense variant S735R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, whereas the SGM‑Consensus (majority vote) supports a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.916840Disordered0.412174Uncertain0.2900.7520.875-6.318Likely Benign0.784Likely PathogenicAmbiguous0.108Likely Benign-1.25Neutral0.997Probably Damaging0.933Probably Damaging2.66Benign0.72Tolerated0.09130.28610-1-3.769.11
c.2205C>G
S735R
2D
AIThe SynGAP1 missense variant S735R has no ClinVar record and is not listed in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while polyPhen‑2 (HumDiv and HumVar) and AlphaMissense‑Default predict a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, whereas the SGM‑Consensus (majority vote) remains Benign; Foldetta results are unavailable. Overall, the balance of evidence—five benign versus three pathogenic predictions, a benign SGM‑Consensus, and no contradictory ClinVar annotation—indicates that the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.916840Disordered0.412174Uncertain0.2900.7520.875-6.318Likely Benign0.784Likely PathogenicAmbiguous0.108Likely Benign-1.25Neutral0.997Probably Damaging0.933Probably Damaging2.66Benign0.72Tolerated0.09130.28610-1-3.769.11
c.3217T>A
S1073T
2D
AIThe SynGAP1 missense variant S1073T is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.916840Disordered0.985818Binding0.3130.9050.750-5.203Likely Benign0.169Likely BenignLikely Benign0.161Likely Benign-0.26Neutral0.025Benign0.026Benign4.06Benign0.55Tolerated0.16960.6509110.114.03
c.3217T>C
S1073P
2D
AIThe SynGAP1 missense variant S1073P is reported in gnomAD (variant ID 6‑33443769‑T‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign impact for S1073P, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.916840Disordered0.985818Binding0.3130.9050.7506-33443769-T-C16.23e-7-4.520Likely Benign0.338Likely BenignLikely Benign0.082Likely Benign-0.76Neutral0.006Benign0.008Benign3.85Benign0.01Affected3.7750.22430.5900-11-0.810.04
c.3217T>G
S1073A
2D
AIThe SynGAP1 missense variant S1073A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) confirms a benign status. Foldetta’s protein‑folding stability analysis is unavailable for this variant. Overall, the preponderance of evidence from multiple prediction algorithms and high‑accuracy tools suggests that the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.916840Disordered0.985818Binding0.3130.9050.750-5.333Likely Benign0.220Likely BenignLikely Benign0.104Likely Benign-0.96Neutral0.447Benign0.103Benign3.95Benign0.02Affected0.45710.5883112.6-16.00
c.3218C>A
S1073Y
2D
AIThe SynGAP1 missense change S1073Y is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.916840Disordered0.985818Binding0.3130.9050.750-6.768Likely Benign0.752Likely PathogenicLikely Benign0.165Likely Benign-2.43Neutral0.990Probably Damaging0.796Possibly Damaging3.81Benign0.00Affected0.09770.5684-3-2-0.576.10
c.3218C>G
S1073C
2D
AISynGAP1 missense variant S1073C is recorded in gnomAD (ID 6‑33443770‑C‑G) but has no ClinVar submission. Functional prediction tools show mixed results: benign calls come from REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized, whereas pathogenic calls are made by polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. The AlphaMissense‑Default score is uncertain. A consensus from the SGM framework (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because the votes are split. High‑accuracy methods give a benign prediction from AlphaMissense‑Optimized; the SGM Consensus remains ambiguous, and Foldetta stability analysis is unavailable. Consequently, the evidence does not strongly favor either outcome. The variant is most likely of uncertain significance, with no contradiction to ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.916840Disordered0.985818Binding0.3130.9050.7506-33443770-C-G16.23e-7-8.862Likely Pathogenic0.461AmbiguousLikely Benign0.137Likely Benign-1.52Neutral0.997Probably Damaging0.840Possibly Damaging3.81Benign0.00Affected3.7750.13430.6088-103.316.06
c.3218C>T
S1073F
2D
AIThe SynGAP1 missense variant S1073F is not reported in ClinVar (ClinVar status: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and FATHMM, whereas those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The high‑accuracy AlphaMissense‑Optimized tool returns an uncertain result, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (2 pathogenic vs. 2 benign). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of available predictions (five pathogenic vs. three benign) lean toward a pathogenic impact. Thus, the variant is most likely pathogenic based on current computational evidence, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.916840Disordered0.985818Binding0.3130.9050.750-6.783Likely Benign0.836Likely PathogenicAmbiguous0.161Likely Benign-2.58Deleterious0.990Probably Damaging0.796Possibly Damaging3.81Benign0.00Affected0.09520.5957-3-23.660.10
c.2824C>A
P942T
2D
AIThe SynGAP1 missense variant P942T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for P942T, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.878102Binding0.3650.9150.625-5.745Likely Benign0.067Likely BenignLikely Benign0.027Likely Benign-1.23Neutral0.224Benign0.096Benign2.49Pathogenic0.00Affected0.16830.55990-10.93.99
c.2824C>G
P942A
2D
AIThe SynGAP1 missense variant P942A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.878102Binding0.3650.9150.625-4.404Likely Benign0.047Likely BenignLikely Benign0.023Likely Benign-0.90Neutral0.059Benign0.061Benign2.52Benign0.00Affected0.33620.46211-13.4-26.04
c.2824C>T
P942S
2D
AIThe SynGAP1 missense variant P942S is catalogued in gnomAD (ID 6‑33443376‑C‑T) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.878102Binding0.3650.9150.6256-33443376-C-T16.20e-7-3.919Likely Benign0.062Likely BenignLikely Benign0.036Likely Benign-0.80Neutral0.011Benign0.015Benign2.43Pathogenic0.00Affected4.3240.32260.4806-110.8-10.04
c.2825C>A
P942Q
2D
AIThe SynGAP1 missense variant P942Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for P942Q, and this conclusion does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.878102Binding0.3650.9150.625-6.094Likely Benign0.080Likely BenignLikely Benign0.028Likely Benign-1.12Neutral0.026Benign0.015Benign2.36Pathogenic0.00Affected0.15080.47030-1-1.931.01
c.2825C>G
P942R
2D
AIThe SynGAP1 missense variant P942R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.878102Binding0.3650.9150.625-5.405Likely Benign0.159Likely BenignLikely Benign0.045Likely Benign-0.78Neutral0.411Benign0.139Benign2.36Pathogenic0.00Affected0.13070.36930-2-2.959.07
c.2825C>T
P942L
2D
AIThe SynGAP1 missense variant P942L is listed in ClinVar (ID 2851884.0) with an “Uncertain” status and is present in gnomAD (variant ID 6‑33443377‑C‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this is consistent with the ClinVar “Uncertain” designation rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.878102Binding0.3650.9150.625Uncertain 16-33443377-C-T42.48e-6-5.063Likely Benign0.086Likely BenignLikely Benign0.048Likely Benign-2.00Neutral0.411Benign0.239Benign2.37Pathogenic0.00Affected4.3240.20940.5507-3-35.416.04
c.3211G>A
G1071S
2D
AIThe SynGAP1 missense variant G1071S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence points to a benign impact for G1071S, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983740Binding0.3130.9050.875-1.139Likely Benign0.168Likely BenignLikely Benign0.093Likely Benign-1.06Neutral0.692Possibly Damaging0.222Benign4.10Benign0.28Tolerated0.24680.545110-0.430.03
c.3211G>C
G1071R
2D
AIThe SynGAP1 missense variant G1071R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and FATHMM. Those that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain. High‑accuracy assessments are inconclusive: AlphaMissense‑Optimized is uncertain; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is a 2‑vs‑2 tie and thus unavailable; Foldetta results are not provided and are therefore unavailable. Overall, more tools predict pathogenicity (5) than benignity (3), and no ClinVar entry contradicts this assessment. **The variant is most likely pathogenic based on the available predictions.**

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.919029Disordered0.983740Binding0.3130.9050.875-3.052Likely Benign0.886Likely PathogenicAmbiguous0.135Likely Benign-2.61Deleterious0.970Probably Damaging0.728Possibly Damaging4.06Benign0.00Affected0.09800.4482-3-2-4.199.14
c.3211G>T
G1071C
2D
AIThe SynGAP1 missense variant G1071C is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign; the Foldetta stability analysis is unavailable. Overall, the majority of evidence—including the consensus and high‑accuracy predictions—supports a benign classification, and this is consistent with the lack of ClinVar annotation. Thus, the variant is most likely benign, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983740Binding0.3130.9050.875-5.364Likely Benign0.305Likely BenignLikely Benign0.182Likely Benign-2.16Neutral0.997Probably Damaging0.889Possibly Damaging4.01Benign0.00Affected0.13230.4227-3-32.946.09
c.3212G>A
G1071D
2D
AIThe SynGAP1 missense variant G1071D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, SGM‑Consensus as Likely Benign, and Foldetta results are unavailable. Overall, the majority of evidence points toward a benign impact, with no conflict with ClinVar status (which has no entry). Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983740Binding0.3130.9050.875-4.704Likely Benign0.866Likely PathogenicAmbiguous0.101Likely Benign-1.92Neutral0.970Probably Damaging0.728Possibly Damaging4.05Benign0.01Affected0.17600.21751-1-3.158.04
c.3212G>C
G1071A
2D
AIThe SynGAP1 missense variant G1071A is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM Consensus—derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign effect, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983740Binding0.3130.9050.875-1.825Likely Benign0.229Likely BenignLikely Benign0.070Likely Benign-1.34Neutral0.025Benign0.022Benign4.12Benign0.05Affected0.33760.5084102.214.03
c.3212G>T
G1071V
2D
AIThe SynGAP1 missense variant G1071V is catalogued in gnomAD (ID 6‑33443764‑G‑T) but has no ClinVar entry. In silico prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign or likely benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the consensus of the majority of tools, including the high‑accuracy methods, supports a benign interpretation. This prediction does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983740Binding0.3130.9050.8756-33443764-G-T31.87e-6-2.901Likely Benign0.300Likely BenignLikely Benign0.110Likely Benign-2.42Neutral0.057Benign0.022Benign4.14Benign0.01Affected3.7750.14080.3634-3-14.642.08
c.3235A>C
S1079R
2D
AIThe SynGAP1 missense variant S1079R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. AlphaMissense‑Optimized returns an uncertain result. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, SGM‑Consensus as Likely Benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta) has no available result for this variant. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983887Binding0.3070.9000.750-4.579Likely Benign0.955Likely PathogenicAmbiguous0.163Likely Benign-1.81Neutral0.177Benign0.075Benign3.86Benign0.00Affected3.7750.08110.40280-1-3.769.11
c.3235A>G
S1079G
2D
AIThe SynGAP1 missense variant S1079G is reported in gnomAD (variant ID 6‑33443787‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign status. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods points to a benign effect. This conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983887Binding0.3070.9000.7506-33443787-A-G63.76e-6-3.552Likely Benign0.177Likely BenignLikely Benign0.065Likely Benign-1.50Neutral0.036Benign0.018Benign3.87Benign0.00Affected3.7750.21510.4623010.4-30.03
c.3235A>T
S1079C
2D
AIThe SynGAP1 missense variant S1079C is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, FATHMM, and AlphaMissense‑Optimized, whereas pathogenic predictions are made by PROVEAN, polyPhen‑2 (HumDiv and HumVar), and SIFT. Two tools—ESM1b and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive, and Foldetta data are unavailable. Overall, the balance of evidence slightly favors a pathogenic interpretation, with four tools supporting pathogenicity versus three supporting benignity. This assessment does not contradict ClinVar status, as the variant has not yet been classified in that database.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.919029Disordered0.983887Binding0.3070.9000.750-7.333In-Between0.370AmbiguousLikely Benign0.138Likely Benign-2.61Deleterious0.898Possibly Damaging0.477Possibly Damaging3.81Benign0.00Affected0.09490.55360-13.316.06
c.3236G>A
S1079N
2D
AIThe SynGAP1 missense variant S1079N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority of the high‑accuracy tools) also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of predictions indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983887Binding0.3070.9000.750-4.989Likely Benign0.505AmbiguousLikely Benign0.026Likely Benign-0.97Neutral0.001Benign0.001Benign3.93Benign0.00Affected0.12250.465711-2.727.03
c.3236G>C
S1079T
2D
AIThe SynGAP1 missense variant S1079T is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores the variant as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports it as Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the computational evidence strongly suggests the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for S1079T.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983887Binding0.3070.9000.750-3.225Likely Benign0.163Likely BenignLikely Benign0.023Likely Benign-1.28Neutral0.001Benign0.003Benign3.91Benign0.00Affected0.12830.5920110.114.03
c.3236G>T
S1079I
2D
AIThe SynGAP1 missense variant S1079I is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 pathogenic vs. 2 benign). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no classification for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.919029Disordered0.983887Binding0.3070.9000.750-4.732Likely Benign0.688Likely PathogenicLikely Benign0.093Likely Benign-2.86Deleterious0.078Benign0.025Benign3.83Benign0.00Affected0.09210.4775-1-25.326.08
c.3237C>A
S1079R
2D
AIThe SynGAP1 missense variant S1079R is listed in ClinVar with an “Uncertain” status and is present in gnomAD (gnomAD ID 6‑33443789‑C‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Those that predict a pathogenic effect are SIFT and AlphaMissense‑Default. AlphaMissense‑Optimized is inconclusive. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments are limited: AlphaMissense‑Optimized remains uncertain, SGM‑Consensus is benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, which does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983887Binding0.3070.9000.750Uncertain 16-33443789-C-A42.51e-6-4.579Likely Benign0.955Likely PathogenicAmbiguous0.123Likely Benign-1.81Neutral0.177Benign0.075Benign3.86Benign0.00Affected3.7750.08110.40280-1-3.769.11
c.3237C>G
S1079R
2D
AIThe SynGAP1 missense variant S1079R is listed in ClinVar (ID 1047537.0) as Benign and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain, and no Foldetta (FoldX‑MD/Rosetta stability) result is available. High‑accuracy assessments therefore show a benign consensus (SGM‑Consensus) with one uncertain AlphaMissense‑Optimized prediction and no destabilizing Foldetta evidence. Overall, the majority of predictions support a benign classification, which is consistent with the ClinVar status and does not contradict it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983887Binding0.3070.9000.750Benign 1-4.579Likely Benign0.955Likely PathogenicAmbiguous0.124Likely Benign-1.81Neutral0.177Benign0.075Benign3.86Benign0.00Affected3.7750.08110.40280-1-3.769.11
c.3277C>A
Q1093K
2D
AIThe SynGAP1 missense variant Q1093K is reported in gnomAD (variant ID 6‑33443829‑C‑A) but has no ClinVar entry. Functional prediction tools uniformly favor a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all classify the change as benign, and AlphaMissense‑Optimized also predicts benign. No tool predicts pathogenicity; AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983312Binding0.3510.8861.0006-33443829-C-A-3.919Likely Benign0.558AmbiguousLikely Benign0.061Likely Benign-0.92Neutral0.224Benign0.091Benign2.78Benign0.06Tolerated3.7750.19260.586111-0.40.04
c.3277C>G
Q1093E
2D
AIThe SynGAP1 missense change Q1093E is not reported in ClinVar and is absent from gnomAD. In silico assessment shows unanimous benign predictions: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign. No tool predicts pathogenicity. High‑accuracy consensus methods reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” The protein‑folding stability predictor Foldetta was not available for this variant. Overall, the evidence strongly supports a benign effect, and this conclusion is consistent with the lack of ClinVar annotation. Thus, the variant is most likely benign and does not contradict existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983312Binding0.3510.8861.000-3.104Likely Benign0.265Likely BenignLikely Benign0.047Likely Benign-0.59Neutral0.112Benign0.041Benign2.78Benign0.07Tolerated0.15140.3717220.00.98
c.3278A>C
Q1093P
2D
AIThe SynGAP1 missense variant Q1093P is not reported in ClinVar and is absent from gnomAD. Consensus from most in silico predictors classifies it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic effect. High‑accuracy assessments reinforce the benign interpretation: AlphaMissense‑Optimized scores benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates likely benign, while Foldetta stability analysis is unavailable. Overall, the evidence points to a benign effect for Q1093P, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983312Binding0.3510.8861.000-2.613Likely Benign0.080Likely BenignLikely Benign0.137Likely Benign-0.96Neutral0.001Benign0.001Benign2.69Benign0.05Affected0.20590.59560-11.9-31.01
c.3278A>G
Q1093R
2D
AIThe SynGAP1 missense variant Q1093R is reported in gnomAD (ID 6‑33443830‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic prediction comes from SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as likely benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983312Binding0.3510.8861.0006-33443830-A-G16.40e-7-3.681Likely Benign0.483AmbiguousLikely Benign0.065Likely Benign-1.06Neutral0.224Benign0.091Benign2.73Benign0.04Affected3.7750.15370.390411-1.028.06
c.3278A>T
Q1093L
2D
AIThe SynGAP1 missense variant Q1093L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983312Binding0.3510.8861.000-3.242Likely Benign0.165Likely BenignLikely Benign0.055Likely Benign-1.10Neutral0.224Benign0.091Benign2.72Benign0.03Affected0.08990.6837-2-27.3-14.97
c.3279G>C
Q1093H
2D
AIThe SynGAP1 missense variant Q1093H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983312Binding0.3510.8861.000-4.003Likely Benign0.337Likely BenignLikely Benign0.060Likely Benign-1.14Neutral0.002Benign0.003Benign2.69Benign0.02Affected0.16000.5269300.39.01
c.3279G>T
Q1093H
2D
AIThe SynGAP1 missense variant Q1093H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983312Binding0.3510.8861.000-4.003Likely Benign0.337Likely BenignLikely Benign0.060Likely Benign-1.14Neutral0.002Benign0.003Benign2.69Benign0.02Affected0.16000.5269300.39.01
c.3289C>A
P1097T
2D
AIThe SynGAP1 missense variant P1097T is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, is not available for this variant. Overall, the computational evidence strongly supports a benign impact, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.974957Binding0.3840.8581.000-5.000Likely Benign0.097Likely BenignLikely Benign0.110Likely Benign-1.38Neutral0.009Benign0.013Benign2.61Benign0.21Tolerated0.17510.65670-10.93.99
c.3289C>G
P1097A
2D
AIThe SynGAP1 missense variant P1097A is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; no tool predicts pathogenicity. The high‑accuracy consensus (SGM‑Consensus, derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the unanimous benign predictions and the lack of any pathogenic evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.974957Binding0.3840.8581.000-4.315Likely Benign0.072Likely BenignLikely Benign0.059Likely Benign-1.77Neutral0.245Benign0.140Benign2.71Benign0.26Tolerated0.31990.53811-13.4-26.04
c.3289C>T
P1097S
2D
AIThe SynGAP1 missense variant P1097S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.974957Binding0.3840.8581.000-3.748Likely Benign0.116Likely BenignLikely Benign0.053Likely Benign-1.04Neutral0.025Benign0.023Benign2.62Benign0.70Tolerated0.33320.56911-10.8-10.04
c.3290C>A
P1097Q
2D
AIThe SynGAP1 missense variant P1097Q is reported in gnomAD (ID 6‑33443842‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.974957Binding0.3840.8581.0006-33443842-C-A-4.765Likely Benign0.198Likely BenignLikely Benign0.092Likely Benign-1.10Neutral0.918Possibly Damaging0.604Possibly Damaging2.58Benign0.12Tolerated3.7750.16130.5136-10-1.931.01
c.3290C>G
P1097R
2D
AIThe SynGAP1 missense variant P1097R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Based on the preponderance of benign predictions and the lack of pathogenic evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.974957Binding0.3840.8581.000-4.938Likely Benign0.422AmbiguousLikely Benign0.079Likely Benign-1.75Neutral0.918Possibly Damaging0.525Possibly Damaging2.58Benign0.07Tolerated0.15170.40270-2-2.959.07
c.3290C>T
P1097L
2D
AIThe SynGAP1 missense variant P1097L is listed in ClinVar as Benign (ClinVar ID 2060978.0) and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as benign; Foldetta results are unavailable. Overall, the majority of evidence supports a benign impact, and this conclusion is consistent with the ClinVar designation. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.974957Binding0.3840.8581.000Benign 1-4.410Likely Benign0.145Likely BenignLikely Benign0.131Likely Benign-2.07Neutral0.611Possibly Damaging0.198Benign2.64Benign0.05Affected3.7750.23490.6356-3-35.416.04
c.3292A>C
S1098R
2D
AIThe SynGAP1 missense variant S1098R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign, reflecting the majority of benign predictions. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, and the SGM‑Consensus (majority vote) also indicates Benign. Foldetta results are not available, so no stability evidence is considered. Overall, the majority of computational evidence supports a benign impact for S1098R, and this is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.973030Binding0.3370.8551.000-4.583Likely Benign0.775Likely PathogenicLikely Benign0.127Likely Benign-1.00Neutral0.586Possibly Damaging0.223Benign2.72Benign0.16Tolerated0.10530.40120-1-3.769.11
c.3292A>G
S1098G
2D
AIThe SynGAP1 missense variant S1098G is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Overall, the collective predictions strongly support a benign impact, and this conclusion is consistent with the lack of a ClinVar pathogenic classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.973030Binding0.3370.8551.000-3.494Likely Benign0.072Likely BenignLikely Benign0.066Likely Benign-0.39Neutral0.000Benign0.001Benign2.72Benign0.57Tolerated0.26340.5206100.4-30.03
c.3292A>T
S1098C
2D
AIThe SynGAP1 missense variant S1098C is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus likewise indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.973030Binding0.3370.8551.000-6.553Likely Benign0.106Likely BenignLikely Benign0.094Likely Benign-1.46Neutral0.938Possibly Damaging0.665Possibly Damaging2.65Benign0.12Tolerated0.12490.62330-13.316.06
c.3293G>A
S1098N
2D
AIThe SynGAP1 missense variant S1098N is listed in ClinVar (ID 864704.0) with an “Uncertain” clinical significance and is present in gnomAD (variant ID 6‑33443845‑G‑A). All evaluated in‑silico predictors agree on a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. No tool predicts pathogenicity. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status is unavailable. Overall, the computational evidence strongly supports a benign classification, which is consistent with the ClinVar “Uncertain” status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.973030Binding0.3370.8551.000Conflicting 26-33443845-G-A63.89e-6-5.120Likely Benign0.156Likely BenignLikely Benign0.063Likely Benign-0.58Neutral0.369Benign0.120Benign2.76Benign0.36Tolerated3.7750.16650.514511-2.727.03
c.3293G>C
S1098T
2D
AIThe SynGAP1 missense variant S1098T is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.973030Binding0.3370.8551.000-4.144Likely Benign0.073Likely BenignLikely Benign0.051Likely Benign-0.18Neutral0.224Benign0.120Benign2.76Benign0.88Tolerated0.17060.6653110.114.03
c.3293G>T
S1098I
2D
AIThe SynGAP1 missense variant S1098I is catalogued in gnomAD (ID 6‑33443845‑G‑T) and has no ClinVar entry. All evaluated in‑silico predictors classify it as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool reports a pathogenic outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.973030Binding0.3370.8551.0006-33443845-G-T-4.497Likely Benign0.182Likely BenignLikely Benign0.139Likely Benign-0.92Neutral0.259Benign0.066Benign2.67Benign0.15Tolerated3.7750.12190.5601-2-15.326.08
c.3294T>A
S1098R
2D
AIThe SynGAP1 missense variant S1098R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign (three benign votes versus one pathogenic). High‑accuracy assessments therefore support a benign outcome: AlphaMissense‑Optimized is benign, SGM‑Consensus is benign, and the protein‑folding stability method Foldetta is not available for this variant. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.973030Binding0.3370.8551.000-4.583Likely Benign0.775Likely PathogenicLikely Benign0.133Likely Benign-1.00Neutral0.586Possibly Damaging0.223Benign2.72Benign0.16Tolerated0.10530.40120-1-3.769.11
c.3294T>G
S1098R
2D
AIThe SynGAP1 missense variant S1098R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign (three benign votes versus one pathogenic). High‑accuracy assessments therefore support a benign outcome: AlphaMissense‑Optimized is benign, SGM‑Consensus is benign, and the protein‑folding stability method Foldetta is not available for this variant. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.973030Binding0.3370.8551.000-4.583Likely Benign0.775Likely PathogenicLikely Benign0.134Likely Benign-1.00Neutral0.586Possibly Damaging0.223Benign2.72Benign0.16Tolerated0.10530.40120-1-3.769.11
c.3391C>A
P1131T
2D
AIThe SynGAP1 missense variant P1131T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this is consistent with the lack of ClinVar annotation. Thus, the variant is most likely benign, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.855155Binding0.3600.8990.750-4.766Likely Benign0.219Likely BenignLikely Benign0.313Likely Benign-2.93Deleterious0.245Benign0.096Benign5.30Benign0.00Affected0.13530.63150-10.93.99
c.3391C>G
P1131A
2D
AIThe SynGAP1 missense variant P1131A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. In contrast, PROVEAN and SIFT predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion is consistent with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.855155Binding0.3600.8990.750-4.785Likely Benign0.171Likely BenignLikely Benign0.207Likely Benign-2.88Deleterious0.009Benign0.008Benign5.36Benign0.00Affected0.29770.55011-13.4-26.04
c.3391C>T
P1131S
2D
AIThe SynGAP1 missense variant P1131S is reported in gnomAD (variant ID 6‑33443943‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. In contrast, PROVEAN and SIFT predict a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this conclusion is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign, and this is not contradictory to ClinVar.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.855155Binding0.3600.8990.7506-33443943-C-T16.72e-7-4.089Likely Benign0.246Likely BenignLikely Benign0.209Likely Benign-2.62Deleterious0.025Benign0.015Benign5.54Benign0.00Affected4.3240.29360.5936-110.8-10.04
c.3392C>A
P1131H
2D
AIThe SynGAP1 missense variant P1131H is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus as benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta) has no available result for this variant. Overall, the balance of evidence leans toward a benign classification, and this assessment does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.919029Disordered0.855155Binding0.3600.8990.750-5.207Likely Benign0.454AmbiguousLikely Benign0.357Likely Benign-3.50Deleterious0.971Probably Damaging0.750Possibly Damaging5.24Benign0.00Affected0.15190.55460-2-1.640.02
c.3392C>G
P1131R
2D
AIThe SynGAP1 P1131R missense variant has no ClinVar record and is absent from gnomAD. Prediction tools cluster into two groups: benign predictions come from REVEL, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions come from PROVEAN, polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a 2‑to‑2 split, and Foldetta data are unavailable. With five benign versus four pathogenic calls and a benign result from the most accurate tool, the variant is most likely benign. This assessment does not contradict ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.919029Disordered0.855155Binding0.3600.8990.750-3.792Likely Benign0.702Likely PathogenicLikely Benign0.416Likely Benign-2.58Deleterious0.918Possibly Damaging0.420Benign5.26Benign0.00Affected0.12520.40100-2-2.959.07
c.3392C>T
P1131L
2D
AIThe SynGAP1 missense variant P1131L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. Tools that predict a pathogenic effect are PROVEAN and SIFT, while AlphaMissense‑Default remains uncertain. The high‑accuracy AlphaMissense‑Optimized tool classifies the variant as benign. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also yields a benign prediction (2 benign vs. 1 pathogenic, with one uncertain). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this assessment does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.919029Disordered0.855155Binding0.3600.8990.750-5.267Likely Benign0.420AmbiguousLikely Benign0.293Likely Benign-3.62Deleterious0.002Benign0.005Benign5.26Benign0.00Affected0.20430.6998-3-35.416.04
c.3394T>A
S1132T
2D
AIThe SynGAP1 missense variant S1132T is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification—there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.845506Binding0.2890.8940.750-3.700Likely Benign0.073Likely BenignLikely Benign0.190Likely Benign-0.71Neutral0.011Benign0.017Benign5.45Benign0.50Tolerated0.15520.6309110.114.03
c.3394T>C
S1132P
2D
AIThe SynGAP1 missense variant S1132P is listed in ClinVar with an uncertain significance (ClinVar ID 1341927.0) and is present in the gnomAD database (gnomAD ID 6‑33443946‑T‑C). All available in‑silico predictors uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign or likely benign outcomes. No tool in the dataset predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status is unavailable. Overall, the computational evidence strongly supports a benign effect, which is consistent with the ClinVar uncertain classification rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.845506Binding0.2890.8940.750Conflicting 36-33443946-T-C16.74e-7-1.423Likely Benign0.144Likely BenignLikely Benign0.301Likely Benign0.38Neutral0.003Benign0.006Benign5.40Benign0.28Tolerated4.3240.20810.57001-1-0.810.04
c.3394T>G
S1132A
2D
AIThe SynGAP1 missense variant S1132A is not reported in ClinVar and is absent from gnomAD, indicating no documented population frequency. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign status. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.845506Binding0.2890.8940.750-3.401Likely Benign0.078Likely BenignLikely Benign0.213Likely Benign-0.60Neutral0.061Benign0.013Benign5.47Benign0.55Tolerated0.44160.5683112.6-16.00
c.3395C>A
S1132Y
2D
AIThe SynGAP1 missense variant S1132Y is listed in ClinVar as a benign alteration (ClinVar ID 845357.0) and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence supports a benign classification, which aligns with the ClinVar status and does not contradict it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.845506Binding0.2890.8940.750Likely Benign 1-5.894Likely Benign0.392AmbiguousLikely Benign0.401Likely Benign-1.76Neutral0.500Possibly Damaging0.208Benign5.40Benign0.09Tolerated4.3240.08890.5233-3-2-0.576.10
c.3395C>G
S1132C
2D
AIThe SynGAP1 missense variant S1132C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for S1132C, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.845506Binding0.2890.8940.750-6.668Likely Benign0.142Likely BenignLikely Benign0.318Likely Benign-1.76Neutral0.977Probably Damaging0.777Possibly Damaging5.39Benign0.06Tolerated0.11990.58880-13.316.06
c.3395C>T
S1132F
2D
AIThe SynGAP1 missense variant S1132F is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from both general and high‑accuracy predictors indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.845506Binding0.2890.8940.750-5.458Likely Benign0.385AmbiguousLikely Benign0.310Likely Benign-2.02Neutral0.006Benign0.006Benign5.41Benign0.05Affected0.09210.5506-3-23.660.10
c.3397A>C
I1133L
2D
AIThe SynGAP1 missense variant I1133L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that I1133L is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.832785Binding0.3160.8920.750-1.147Likely Benign0.107Likely BenignLikely Benign0.202Likely Benign-0.26Neutral0.000Benign0.001Benign5.48Benign0.23Tolerated0.09110.430222-0.70.00
c.3397A>G
I1133V
2D
AIThe SynGAP1 missense variant I1133V is listed in ClinVar as Benign (ClinVar ID 999690.0) and is present in the gnomAD database (gnomAD ID 6‑33443949‑A‑G). All evaluated in‑silico predictors classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is Likely Benign. Foldetta results are unavailable. Consequently, the variant is most likely benign, and this prediction aligns with its ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.832785Binding0.3160.8920.750Benign 16-33443949-A-G221.48e-5-3.362Likely Benign0.067Likely BenignLikely Benign0.180Likely Benign0.06Neutral0.007Benign0.007Benign5.47Benign0.58Tolerated4.3230.11900.398543-0.3-14.0310.1016/j.ajhg.2020.11.011
c.3397A>T
I1133F
2D
AIThe SynGAP1 missense variant I1133F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect. The variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.832785Binding0.3160.8920.750-2.941Likely Benign0.164Likely BenignLikely Benign0.272Likely Benign-1.21Neutral0.290Benign0.124Benign5.45Benign0.05Affected0.05980.352210-1.734.02
c.3398T>A
I1133N
2D
AIThe SynGAP1 missense variant I1133N is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign. Pathogenicity is suggested only by polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates Likely Benign; Foldetta stability analysis is unavailable. Overall, the preponderance of evidence points to a benign effect for I1133N, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.832785Binding0.3160.8920.750-5.887Likely Benign0.520AmbiguousLikely Benign0.290Likely Benign-1.07Neutral0.453Possibly Damaging0.162Benign5.51Benign0.02Affected0.09610.1140-2-3-8.00.94
c.3398T>C
I1133T
2D
AIThe SynGAP1 missense variant I1133T has no ClinVar entry and is present in gnomAD (ID 6‑33443950‑T‑C). Consensus among most tools is benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict a benign effect, while AlphaMissense‑Default remains uncertain and no tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates “Likely Benign,” and Foldetta’s protein‑folding stability analysis is unavailable. Overall, the evidence strongly supports a benign classification, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.832785Binding0.3160.8920.7506-33443950-T-C-4.522Likely Benign0.563AmbiguousLikely Benign0.275Likely Benign-0.30Neutral0.026Benign0.030Benign5.50Benign0.18Tolerated4.3230.10070.1975-10-5.2-12.05
c.3398T>G
I1133S
2D
AIThe SynGAP1 missense variant I1133S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is likely benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the collective evidence strongly supports a benign impact for I1133S, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.832785Binding0.3160.8920.750-4.034Likely Benign0.492AmbiguousLikely Benign0.186Likely Benign-0.60Neutral0.007Benign0.016Benign5.70Benign0.08Tolerated0.27620.1110-1-2-5.3-26.08
c.3399C>G
I1133M
2D
AIThe SynGAP1 missense variant I1133M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is benign, and this conclusion does not contradict any ClinVar annotation (none present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.832785Binding0.3160.8920.750-3.409Likely Benign0.096Likely BenignLikely Benign0.223Likely Benign-0.21Neutral0.016Benign0.009Benign5.45Benign0.06Tolerated0.07640.368521-2.618.03
c.3424T>A
S1142T
2D
AIThe SynGAP1 missense variant S1142T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.719935Binding0.2760.8441.000-3.712Likely Benign0.100Likely BenignLikely Benign0.106Likely Benign-1.63Neutral0.611Possibly Damaging0.324Benign2.69Benign0.00Affected0.15480.6427110.114.03
c.3424T>C
S1142P
2D
AIThe SynGAP1 missense variant S1142P is listed in ClinVar (ID 2747352.0) as Benign and is present in gnomAD (variant ID 6‑33444459‑T‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, aligning with the ClinVar classification and not contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.719935Binding0.2760.8441.000Likely Benign 16-33444459-T-C16.20e-7-2.713Likely Benign0.222Likely BenignLikely Benign0.107Likely Benign-2.19Neutral0.918Possibly Damaging0.761Possibly Damaging2.64Benign0.00Affected4.3240.20800.5618-11-0.810.04
c.3424T>G
S1142A
2D
AIThe SynGAP1 missense variant S1142A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) confirms a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that S1142A is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.719935Binding0.2760.8441.000-3.694Likely Benign0.085Likely BenignLikely Benign0.074Likely Benign-1.31Neutral0.002Benign0.015Benign2.73Benign0.00Affected0.46890.5319112.6-16.00
c.3425C>A
S1142Y
2D
AIThe SynGAP1 missense variant S1142Y is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized predicts a benign outcome, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (2 pathogenic vs. 2 benign). Foldetta results are unavailable. Overall, the majority of conventional predictors lean toward pathogenicity, but the single high‑accuracy benign prediction and the inconclusive consensus temper this view. Thus, the variant is most likely pathogenic based on the current predictions, and this assessment does not contradict any ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.919029Disordered0.719935Binding0.2760.8441.000-6.146Likely Benign0.569Likely PathogenicLikely Benign0.200Likely Benign-3.39Deleterious0.971Probably Damaging0.876Possibly Damaging2.64Benign0.00Affected0.08490.5429-3-2-0.576.10
c.3425C>G
S1142C
2D
AIThe SynGAP1 missense variant S1142C is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized, while pathogenic predictions come from PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; ESM1b remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields benign, and Foldetta data are unavailable. Consequently, the variant is most likely benign based on the collective evidence, and this conclusion does not conflict with any ClinVar annotation because no ClinVar entry exists for this change.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.919029Disordered0.719935Binding0.2760.8441.000-7.355In-Between0.182Likely BenignLikely Benign0.146Likely Benign-2.89Deleterious0.992Probably Damaging0.866Possibly Damaging2.70Benign0.00Affected0.11700.60160-13.316.06
c.3425C>T
S1142F
2D
AIThe SynGAP1 missense variant S1142F has no ClinVar record and is not present in gnomAD. Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic outcome are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign majority, and Foldetta data are unavailable. Overall, the balance of evidence—especially from the high‑accuracy tools—suggests that the variant is most likely benign. This conclusion does not contradict ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.919029Disordered0.719935Binding0.2760.8441.000-5.074Likely Benign0.508AmbiguousLikely Benign0.206Likely Benign-3.70Deleterious0.918Possibly Damaging0.827Possibly Damaging2.65Benign0.00Affected0.08610.5603-3-23.660.10
c.3427A>C
T1143P
2D
AIThe SynGAP1 missense variant T1143P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic effect. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.722918Binding0.2750.8371.000-2.307Likely Benign0.155Likely BenignLikely Benign0.183Likely Benign0.80Neutral0.999Probably Damaging0.966Probably Damaging2.69Benign0.24Tolerated0.18180.41080-1-0.9-3.99
c.3427A>G
T1143A
2D
AIThe SynGAP1 missense variant T1143A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Based on the preponderance of benign predictions and the consensus from high‑accuracy methods, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.722918Binding0.2750.8371.000-3.340Likely Benign0.159Likely BenignLikely Benign0.061Likely Benign-1.19Neutral0.877Possibly Damaging0.675Possibly Damaging2.80Benign0.43Tolerated0.32520.3546102.5-30.03
c.3427A>T
T1143S
2D
AIThe SynGAP1 missense variant T1143S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods indicates that T1143S is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.722918Binding0.2750.8371.000-2.427Likely Benign0.150Likely BenignLikely Benign0.086Likely Benign-1.34Neutral0.573Possibly Damaging0.230Benign2.76Benign0.74Tolerated0.28100.364011-0.1-14.03
c.3428C>A
T1143K
2D
AIThe SynGAP1 missense variant T1143K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, whereas the SGM‑Consensus (majority vote) supports a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact for T1143K, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.722918Binding0.2750.8371.000-3.498Likely Benign0.811Likely PathogenicAmbiguous0.163Likely Benign-2.03Neutral0.986Probably Damaging0.895Possibly Damaging2.78Benign0.14Tolerated0.12660.29360-1-3.227.07
c.3428C>G
T1143R
2D
AIThe SynGAP1 missense variant T1143R is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools cluster into two groups: benign predictions include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions come from AlphaMissense‑Default, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.722918Binding0.2750.8371.000-2.882Likely Benign0.782Likely PathogenicLikely Benign0.175Likely Benign-2.31Neutral0.996Probably Damaging0.951Probably Damaging2.73Benign0.09Tolerated0.10870.3060-1-1-3.855.08
c.3428C>T
T1143I
2D
AIThe SynGAP1 missense variant T1143I is not reported in ClinVar and has no entries in gnomAD, indicating it has not been catalogued in these databases. Functional prediction tools largely agree that the substitution is benign: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify it as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic effect. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy predictions from AlphaMissense‑Optimized and the SGM‑Consensus both support a benign outcome, while the absence of a Foldetta result leaves the structural impact unresolved. Overall, the majority of evidence points to a benign effect, and this conclusion is consistent with the lack of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.722918Binding0.2750.8371.000-3.554Likely Benign0.560AmbiguousLikely Benign0.163Likely Benign-1.87Neutral0.999Probably Damaging0.966Probably Damaging2.68Benign0.10Tolerated0.10130.42740-15.212.05
c.3436C>A
P1146T
2D
AIThe SynGAP1 missense variant P1146T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and polyPhen‑2 HumVar, as well as the SGM‑Consensus call of “Likely Benign.” In contrast, PROVEAN, polyPhen‑2 HumDiv, and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores benign, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. Foldetta results are not available. Overall, the majority of evidence points to a benign effect for P1146T, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.732173Binding0.4150.8371.000-3.494Likely Benign0.272Likely BenignLikely Benign0.454Likely Benign-4.11Deleterious0.573Possibly Damaging0.334Benign5.51Benign0.00Affected0.14780.57890-10.93.99
c.3436C>G
P1146A
2D
AIThe SynGAP1 missense variant P1146A is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, tools that predict a pathogenic outcome are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for P1146A, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.732173Binding0.4150.8371.000-3.896Likely Benign0.203Likely BenignLikely Benign0.300Likely Benign-3.56Deleterious0.972Probably Damaging0.760Possibly Damaging5.53Benign0.00Affected0.35160.47911-13.4-26.04
c.3436C>T
P1146S
2D
AIThe SynGAP1 missense variant P1146S is reported in ClinVar as “Not submitted” and is present in gnomAD (variant ID 6-33444471-C‑T). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this is consistent with the lack of a ClinVar pathogenic classification. Thus, the variant is most likely benign, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.732173Binding0.4150.8371.0006-33444471-C-T21.24e-6-3.045Likely Benign0.318Likely BenignLikely Benign0.470Likely Benign-3.66Deleterious0.945Possibly Damaging0.760Possibly Damaging5.52Benign0.00Affected4.3240.34080.5186-110.8-10.04
c.3437C>A
P1146H
2D
AIThe SynGAP1 missense variant P1146H is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include ESM1b, FATHMM, and AlphaMissense‑Optimized, whereas a majority of tools (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT) predict a pathogenic impact; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign outcome (2 benign vs. 1 pathogenic, 1 uncertain). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence points to a pathogenic effect, and this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.919029Disordered0.732173Binding0.4150.8371.000-4.428Likely Benign0.518AmbiguousLikely Benign0.529Likely Pathogenic-4.93Deleterious1.000Probably Damaging0.983Probably Damaging5.46Benign0.00Affected0.16250.45120-2-1.640.02
c.3437C>G
P1146R
2D
AIThe SynGAP1 missense variant P1146R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a pathogenic effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. Tools that agree on a benign effect are ESM1b, FATHMM, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized predicts a benign outcome, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive due to a 2‑vs‑2 split, and Foldetta results are unavailable. Overall, the majority of available predictions (seven pathogenic versus three benign) indicate that the variant is most likely pathogenic. This conclusion is not contradicted by ClinVar status, as the variant has no existing ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.919029Disordered0.732173Binding0.4150.8371.000-3.826Likely Benign0.729Likely PathogenicLikely Benign0.603Likely Pathogenic-4.81Deleterious0.996Probably Damaging0.967Probably Damaging5.50Benign0.00Affected0.13150.31930-2-2.959.07
c.3437C>T
P1146L
2D
AISynGAP1 missense variant P1146L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include ESM1b, FATHMM, and AlphaMissense‑Optimized, whereas a separate group predicts pathogenicity: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), and SIFT. AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also favors a benign outcome, while Foldetta results are unavailable. Overall, the majority of conventional predictors indicate pathogenicity, but the most accurate tools lean benign. Thus, the variant is most likely pathogenic based on the collective predictions, and this assessment does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.919029Disordered0.732173Binding0.4150.8371.000-2.182Likely Benign0.483AmbiguousLikely Benign0.564Likely Pathogenic-5.25Deleterious0.992Probably Damaging0.912Probably Damaging5.51Benign0.00Affected0.21510.6446-3-35.416.04
c.3991A>C
I1331L
2D
AIThe SynGAP1 missense variant I1331L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), which collectively classify the variant as likely benign. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The high‑accuracy AlphaMissense‑Optimized result is uncertain, and Foldetta stability analysis is unavailable. Overall, the balance of evidence leans toward a benign interpretation, with no conflict with ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.921076Disordered0.941705Binding0.3590.7520.875-2.450Likely Benign0.892Likely PathogenicAmbiguous0.180Likely Benign-1.04Neutral0.762Possibly Damaging0.785Possibly Damaging3.45Benign0.00Affected0.07520.361622-0.70.00
c.3991A>G
I1331V
2D
AIThe SynGAP1 missense variant I1331V is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as “Uncertain,” SGM‑Consensus as “Likely Benign,” and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.921076Disordered0.941705Binding0.3590.7520.875-2.799Likely Benign0.899Likely PathogenicAmbiguous0.138Likely Benign-0.51Neutral0.581Possibly Damaging0.785Possibly Damaging3.59Benign0.00Affected0.10910.307443-0.3-14.03
c.3991A>T
I1331F
2D
AIThe SynGAP1 missense variant I1331F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as “Uncertain” and the SGM‑Consensus as “Likely Benign”; Foldetta results are unavailable. Overall, the balance of evidence leans toward a benign interpretation, with no ClinVar entry to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.921076Disordered0.941705Binding0.3590.7520.875-4.220Likely Benign0.946Likely PathogenicAmbiguous0.181Likely Benign-2.46Neutral0.984Probably Damaging0.969Probably Damaging3.31Benign0.00Affected0.05220.322510-1.734.02
c.3992T>A
I1331N
2D
AIThe SynGAP1 missense variant I1331N is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33451866‑T‑A). Prediction tools that agree on a benign effect include REVEL, ESM1b, and FATHMM, whereas those that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (2 vs 2), and Foldetta results are unavailable. Overall, the majority of evaluated tools predict a pathogenic impact, and there is no conflict with ClinVar status. Thus, the variant is most likely pathogenic.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.921076Disordered0.941705Binding0.3590.7520.8756-33451866-T-A-3.788Likely Benign0.994Likely PathogenicLikely Pathogenic0.237Likely Benign-4.09Deleterious0.984Probably Damaging0.979Probably Damaging3.29Benign0.00Affected3.7750.10120.0666-3-2-8.00.94
c.3992T>C
I1331T
2D
AIThe SynGAP1 missense variant I1331T is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and FATHMM. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized predicts pathogenic. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (two pathogenic vs. two benign). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence (seven pathogenic vs. three benign predictions) indicates that the variant is most likely pathogenic, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.921076Disordered0.941705Binding0.3590.7520.875-2.953Likely Benign0.999Likely PathogenicLikely Pathogenic0.170Likely Benign-2.69Deleterious0.947Possibly Damaging0.950Probably Damaging3.32Benign0.00Affected0.11150.15500-1-5.2-12.05
c.3992T>G
I1331S
2D
AIThe SynGAP1 I1331S variant is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and FATHMM. Tools that agree on a pathogenic effect include PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized predicts pathogenicity, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive due to a 2‑to‑2 split, and Foldetta results are unavailable. Overall, the majority of evidence (six pathogenic vs. three benign predictions) indicates that the variant is most likely pathogenic. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.921076Disordered0.941705Binding0.3590.7520.875-3.014Likely Benign0.997Likely PathogenicLikely Pathogenic0.230Likely Benign-3.40Deleterious0.984Probably Damaging0.969Probably Damaging3.30Benign0.00Affected0.29290.0836-1-2-5.3-26.08
c.3993T>G
I1331M
2D
AIThe SynGAP1 I1331M missense variant has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on benign impact include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict pathogenicity are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, and Foldetta results are unavailable. Considering the majority of consensus‑based and individual predictors, the variant is most likely benign. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.921076Disordered0.941705Binding0.3590.7520.875-4.202Likely Benign0.883Likely PathogenicAmbiguous0.143Likely Benign-1.69Neutral0.984Probably Damaging0.979Probably Damaging3.32Benign0.00Affected0.06980.322021-2.618.03
c.4024G>A
D1342N
2D
AIThe SynGAP1 missense variant D1342N is catalogued in gnomAD (ID 6‑33451898‑G‑A) but has no ClinVar submission. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the substitution as tolerated or benign. Grouping by consensus, all listed predictors fall into the benign category, with no tool reporting pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta stability analysis is unavailable for this variant. Consequently, the aggregate evidence strongly supports a benign classification, and this assessment does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.921076Disordered0.981682Binding0.3160.6780.8756-33451898-G-A-3.459Likely Benign0.140Likely BenignLikely Benign0.058Likely Benign0.29Neutral0.000Benign0.002Benign4.07Benign0.93Tolerated4.3240.18680.6022120.0-0.98
c.4024G>C
D1342H
2D
AIThe SynGAP1 missense variant D1342H is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and SIFT—suggest a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Overall, the consensus of available predictions indicates that D1342H is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.921076Disordered0.981682Binding0.3160.6780.875-3.765Likely Benign0.310Likely BenignLikely Benign0.039Likely Benign-0.56Neutral0.834Possibly Damaging0.400Benign4.00Benign0.02Affected0.23650.61771-10.322.05
c.4024G>T
D1342Y
2D
AIThe SynGAP1 missense variant D1342Y is reported in gnomAD (6‑33451898‑G‑T) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions are made by polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar status (none available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.921076Disordered0.981682Binding0.3160.6780.8756-33451898-G-T-4.108Likely Benign0.398AmbiguousLikely Benign0.095Likely Benign-1.34Neutral0.939Possibly Damaging0.496Possibly Damaging3.98Benign0.01Affected4.3240.08680.5377-3-42.248.09
c.4025A>C
D1342A
2D
AIThe SynGAP1 missense variant D1342A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized reports a benign effect, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are unavailable. Overall, the preponderance of evidence supports a benign classification for D1342A, and this conclusion does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.921076Disordered0.981682Binding0.3160.6780.875-2.719Likely Benign0.145Likely BenignLikely Benign0.049Likely Benign-0.58Neutral0.371Benign0.084Benign4.06Benign0.02Affected0.42700.56760-25.3-44.01
c.4025A>G
D1342G
2D
AIThe SynGAP1 missense variant D1342G is reported in gnomAD (variant ID 6‑33451899‑A‑G) but has no ClinVar entry. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.921076Disordered0.981682Binding0.3160.6780.8756-33451899-A-G17.29e-7-3.227Likely Benign0.129Likely BenignLikely Benign0.021Likely Benign-0.89Neutral0.225Benign0.045Benign4.05Benign0.09Tolerated4.3240.36330.5601-113.1-58.04
c.4025A>T
D1342V
2D
AIThe SynGAP1 missense variant D1342V is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign and the SGM‑Consensus also indicating a likely benign outcome; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.921076Disordered0.981682Binding0.3160.6780.875-2.890Likely Benign0.317Likely BenignLikely Benign0.089Likely Benign-1.27Neutral0.588Possibly Damaging0.212Benign4.01Benign0.00Affected0.12140.5617-2-37.7-15.96
c.4026C>A
D1342E
2D
AIThe SynGAP1 missense variant D1342E is catalogued in gnomAD (ID 6‑33451900‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign or tolerated outcomes. Only SIFT predicts a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates that D1342E is most likely benign, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.921076Disordered0.981682Binding0.3160.6780.8756-33451900-C-A-3.169Likely Benign0.134Likely BenignLikely Benign0.026Likely Benign-0.88Neutral0.225Benign0.084Benign4.16Benign0.04Affected4.3240.21300.5720230.014.03
c.4026C>G
D1342E
2D
AIThe SynGAP1 missense variant D1342E is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is likely benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the consensus of available predictions points to a benign effect for D1342E, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.921076Disordered0.981682Binding0.3160.6780.875-3.169Likely Benign0.134Likely BenignLikely Benign0.026Likely Benign-0.88Neutral0.225Benign0.084Benign4.16Benign0.04Affected4.3240.21300.5720230.014.03
c.3214A>C
K1072Q
2D
AIThe SynGAP1 missense variant K1072Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation because no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.984675Binding0.3070.9070.750-1.631Likely Benign0.589Likely PathogenicLikely Benign0.081Likely Benign-0.63Neutral0.999Probably Damaging0.995Probably Damaging3.95Benign0.12Tolerated0.44650.1804110.4-0.04
c.3214A>G
K1072E
2D
AIThe SynGAP1 missense variant K1072E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools show mixed results: benign predictions come from REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions are returned by polyPhen‑2 HumDiv, polyPhen‑2 HumVar, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments indicate that AlphaMissense‑Optimized classifies the variant as pathogenic, whereas the SGM‑Consensus (derived from the same set of predictors) labels it as likely benign. No Foldetta stability analysis is available for this residue. Overall, the majority of tools lean toward a benign effect, but the presence of pathogenic calls from several high‑confidence predictors suggests uncertainty. The variant is most likely benign based on the preponderance of evidence, and this conclusion does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.984675Binding0.3070.9070.750-3.889Likely Benign0.961Likely PathogenicLikely Pathogenic0.105Likely Benign-0.90Neutral0.997Probably Damaging0.989Probably Damaging3.96Benign0.08Tolerated0.36360.1874010.40.94
c.3215A>C
K1072T
2D
AIThe SynGAP1 missense variant K1072T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, and the SGM‑Consensus result is benign; Foldetta predictions are unavailable. Overall, the balance of evidence leans toward a benign impact. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.984675Binding0.3070.9070.750-2.557Likely Benign0.834Likely PathogenicAmbiguous0.082Likely Benign-1.31Neutral0.999Probably Damaging0.995Probably Damaging3.92Benign0.06Tolerated0.19670.43070-13.2-27.07
c.3215A>G
K1072R
2D
AIThe SynGAP1 missense variant K1072R is reported in gnomAD (ID 6‑33443767‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict it to be pathogenic. When predictions are grouped by consensus, the benign group contains seven tools, whereas the pathogenic group contains two. High‑accuracy assessments reinforce the benign view: AlphaMissense‑Optimized reports a benign outcome, and the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign effect. No Foldetta stability data are available, so folding‑stability evidence is unavailable. Overall, the majority of evidence points to a benign impact, and this is not in conflict with ClinVar status, which currently has no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.984675Binding0.3070.9070.7506-33443767-A-G16.23e-7-2.458Likely Benign0.100Likely BenignLikely Benign0.116Likely Benign-0.15Neutral0.997Probably Damaging0.989Probably Damaging4.16Benign0.88Tolerated3.7750.46550.206123-0.628.01
c.3215A>T
K1072M
2D
AIThe SynGAP1 K1072M missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points toward a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign based on current predictive data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.984675Binding0.3070.9070.750-2.821Likely Benign0.928Likely PathogenicAmbiguous0.144Likely Benign-1.37Neutral1.000Probably Damaging0.998Probably Damaging3.88Benign0.02Affected0.12660.48770-15.83.02
c.3216G>C
K1072N
2D
AIThe SynGAP1 missense variant K1072N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as “Uncertain” and the SGM‑Consensus as “Likely Benign”; Foldetta results are not available. Overall, the balance of evidence leans toward a benign impact, with no ClinVar entry to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.984675Binding0.3070.9070.750-2.215Likely Benign0.953Likely PathogenicAmbiguous0.078Likely Benign-1.18Neutral0.999Probably Damaging0.995Probably Damaging3.92Benign0.05Affected0.34490.2391100.4-14.07
c.3216G>T
K1072N
2D
AIThe SynGAP1 missense variant K1072N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as “Uncertain” and the SGM‑Consensus as “Likely Benign”; Foldetta results are not available. Overall, the balance of evidence leans toward a benign impact, with no ClinVar entry to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.984675Binding0.3070.9070.750-2.215Likely Benign0.953Likely PathogenicAmbiguous0.078Likely Benign-1.18Neutral0.999Probably Damaging0.995Probably Damaging3.92Benign0.05Affected0.34490.2391100.4-14.07
c.3223C>A
Q1075K
2D
AIThe SynGAP1 missense variant Q1075K (ClinVar ID 2762879.0) is listed as “Uncertain” in ClinVar and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is “Likely Benign” because three of the four contributing tools predict benign. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote) as benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.988305Binding0.3540.8940.750Uncertain 1-5.135Likely Benign0.728Likely PathogenicLikely Benign0.134Likely Benign-0.67Neutral0.963Probably Damaging0.959Probably Damaging2.75Benign1.00Tolerated3.7750.18980.441111-0.40.04
c.3223C>G
Q1075E
2D
AIThe SynGAP1 missense variant Q1075E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default remains uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. High‑accuracy assessments therefore indicate a benign outcome: AlphaMissense‑Optimized predicts benign, SGM‑Consensus is Likely Benign, and Foldetta data is missing. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.988305Binding0.3540.8940.750-2.275Likely Benign0.401AmbiguousLikely Benign0.065Likely Benign-0.70Neutral0.963Probably Damaging0.959Probably Damaging2.75Benign0.25Tolerated0.14590.2463220.00.98
c.3224A>C
Q1075P
2D
AIThe SynGAP1 missense variant Q1075P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only two tools, polyPhen‑2 HumDiv and HumVar, predict a pathogenic outcome. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy methods corroborate this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the consensus of the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.988305Binding0.3540.8940.750-1.854Likely Benign0.086Likely BenignLikely Benign0.175Likely Benign0.78Neutral0.996Probably Damaging0.988Probably Damaging2.68Benign0.28Tolerated0.22880.57410-11.9-31.01
c.3224A>G
Q1075R
2D
AIThe SynGAP1 missense variant Q1075R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and AlphaMissense‑Default predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar status, as none is assigned to the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.988305Binding0.3540.8940.750-5.039Likely Benign0.697Likely PathogenicLikely Benign0.142Likely Benign-0.37Neutral0.985Probably Damaging0.973Probably Damaging2.72Benign0.93Tolerated0.15040.265011-1.028.06
c.3224A>T
Q1075L
2D
AIThe SynGAP1 missense variant Q1075L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools, polyPhen‑2 HumDiv and HumVar, predict pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy methods confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence supports a benign impact for Q1075L, and this conclusion is consistent with the absence of a ClinVar assertion. The variant is most likely benign based on predictions, and there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.988305Binding0.3540.8940.750-3.976Likely Benign0.209Likely BenignLikely Benign0.128Likely Benign-2.10Neutral0.985Probably Damaging0.973Probably Damaging2.72Benign0.15Tolerated0.08880.6454-2-27.3-14.97
c.3225G>C
Q1075H
2D
AIThe SynGAP1 missense variant Q1075H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, the SGM‑Consensus also indicates likely benign, while Foldetta data is missing. Overall, the majority of reliable predictors classify the variant as benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.988305Binding0.3540.8940.750-4.616Likely Benign0.486AmbiguousLikely Benign0.072Likely Benign-1.06Neutral0.996Probably Damaging0.992Probably Damaging2.68Benign0.13Tolerated0.14570.4214300.39.01
c.3225G>T
Q1075H
2D
AIThe SynGAP1 missense variant Q1075H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, the SGM‑Consensus also indicates likely benign, while Foldetta data is missing. Overall, the majority of reliable predictors classify the variant as benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.988305Binding0.3540.8940.750-4.616Likely Benign0.486AmbiguousLikely Benign0.072Likely Benign-1.06Neutral0.996Probably Damaging0.992Probably Damaging2.68Benign0.13Tolerated0.14570.4214300.39.01
c.3226T>A
L1076M
2D
AIThe SynGAP1 missense variant L1076M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of predictions (six benign vs. four pathogenic) lean toward a benign interpretation. Thus, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.989617Binding0.3010.8920.750-5.047Likely Benign0.320Likely BenignLikely Benign0.087Likely Benign0.02Neutral0.999Probably Damaging0.995Probably Damaging2.42Pathogenic0.04Affected0.08860.414742-1.918.03
c.3226T>G
L1076V
2D
AIThe SynGAP1 missense variant L1076V is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign, while Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.989617Binding0.3010.8920.750-3.615Likely Benign0.344AmbiguousLikely Benign0.097Likely Benign-0.56Neutral0.995Probably Damaging0.982Probably Damaging2.53Benign0.11Tolerated0.16320.3781210.4-14.03
c.3227T>C
L1076S
2D
AIThe SynGAP1 missense variant L1076S is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, and ESM1b, whereas polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Default all predict a pathogenic outcome. High‑accuracy assessments are less decisive: AlphaMissense‑Optimized is uncertain; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (two benign vs. two pathogenic votes); and Foldetta results are unavailable. Consequently, the evidence is evenly split between benign and pathogenic predictions. The variant is therefore most likely of uncertain significance, and this assessment does not contradict the absence of a ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.922952Disordered0.989617Binding0.3010.8920.750-2.975Likely Benign0.913Likely PathogenicAmbiguous0.225Likely Benign0.55Neutral0.999Probably Damaging0.983Probably Damaging2.43Pathogenic0.75Tolerated0.30450.1178-3-2-4.6-26.08
c.3227T>G
L1076W
2D
AIThe SynGAP1 missense variant L1076W is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, and ESM1b, whereas those that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. The high‑accuracy AlphaMissense‑Optimized tool returns an uncertain result, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 pathogenic vs. 2 benign). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evaluated predictors (five pathogenic vs. three benign) lean toward a pathogenic interpretation. This prediction is not contradicted by ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.922952Disordered0.989617Binding0.3010.8920.750-6.377Likely Benign0.822Likely PathogenicAmbiguous0.183Likely Benign-1.40Neutral1.000Probably Damaging0.996Probably Damaging2.38Pathogenic0.02Affected0.07490.3740-2-2-4.773.05
c.3228G>C
L1076F
2D
AIThe SynGAP1 missense variant L1076F is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that classify the variant as benign include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Those that predict pathogenicity are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a 2‑to‑2 split, and Foldetta results are unavailable. Overall, the majority of predictions (5 pathogenic vs. 4 benign) lean toward pathogenicity, and this is consistent with the lack of ClinVar annotation. Thus, the variant is most likely pathogenic, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.922952Disordered0.989617Binding0.3010.8920.750-4.606Likely Benign0.675Likely PathogenicLikely Benign0.092Likely Benign-0.92Neutral0.999Probably Damaging0.995Probably Damaging2.42Pathogenic0.03Affected0.07590.376720-1.034.02
c.3228G>T
L1076F
2D
AIThe SynGAP1 missense variant L1076F is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that classify the variant as benign include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Those that predict pathogenicity are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a 2‑to‑2 split, and Foldetta results are unavailable. Overall, the majority of predictions (5 pathogenic vs. 4 benign) lean toward pathogenicity, and this is consistent with the lack of ClinVar annotation. Thus, the variant is most likely pathogenic, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.922952Disordered0.989617Binding0.3010.8920.750-4.606Likely Benign0.675Likely PathogenicLikely Benign0.092Likely Benign-0.92Neutral0.999Probably Damaging0.995Probably Damaging2.42Pathogenic0.03Affected0.07590.376720-1.034.02
c.3283C>A
P1095T
2D
AIThe SynGAP1 missense variant P1095T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only polyPhen‑2 HumDiv indicates a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Overall, the consensus of the available predictions points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.979251Binding0.3870.8701.000-4.706Likely Benign0.195Likely BenignLikely Benign0.108Likely Benign-1.42Neutral0.872Possibly Damaging0.399Benign2.77Benign0.13Tolerated0.16850.66770-10.93.99
c.3283C>G
P1095A
2D
AIThe SynGAP1 missense variant P1095A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only polyPhen‑2 HumDiv indicates a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Overall, the consensus of the available predictions points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.979251Binding0.3870.8701.000-4.555Likely Benign0.129Likely BenignLikely Benign0.060Likely Benign-0.80Neutral0.580Possibly Damaging0.242Benign2.79Benign0.18Tolerated0.31220.57031-13.4-26.04
c.3283C>T
P1095S
2D
AIThe SynGAP1 missense variant P1095S is reported in gnomAD (ID 6‑33443835‑C‑T) and has no ClinVar entry. All evaluated in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Based on the unanimous benign predictions and the absence of any pathogenic signal, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.979251Binding0.3870.8701.0006-33443835-C-T74.51e-6-3.819Likely Benign0.182Likely BenignLikely Benign0.128Likely Benign-0.64Neutral0.207Benign0.072Benign2.80Benign1.00Tolerated3.7750.31500.5963-110.8-10.04
c.3284C>A
P1095Q
2D
AIThe SynGAP1 missense variant P1095Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv flags it as pathogenic, but this is the sole discordant call. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.979251Binding0.3870.8701.000-4.171Likely Benign0.295Likely BenignLikely Benign0.110Likely Benign-1.64Neutral0.922Possibly Damaging0.441Benign2.85Benign0.45Tolerated0.15730.55190-1-1.931.01
c.3284C>G
P1095R
2D
AIThe SynGAP1 missense variant P1095R is reported in ClinVar as “Not submitted” and is not present in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, all of which classify the change as benign or tolerant. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT predict a pathogenic impact. AlphaMissense‑Default remains uncertain, and no Foldetta stability assessment is available. High‑accuracy consensus methods reinforce the benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign,” and Foldetta data are missing. Overall, the majority of reliable predictors and consensus analyses indicate that P1095R is most likely benign, and this conclusion does not contradict the ClinVar status, which currently contains no pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.979251Binding0.3870.8701.000-5.180Likely Benign0.553AmbiguousLikely Benign0.091Likely Benign-1.93Neutral0.922Possibly Damaging0.528Possibly Damaging2.77Benign0.04Affected0.15130.45760-2-2.959.07
c.3284C>T
P1095L
2D
AIThe SynGAP1 missense variant P1095L is catalogued in gnomAD (ID 6‑33443836‑C‑T) but has no ClinVar record. Functional prediction tools cluster into two groups: benign predictions come from REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from PROVEAN, polyPhen‑2 (HumDiv and HumVar), and SIFT; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors benign, and Foldetta data are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.922952Disordered0.979251Binding0.3870.8701.0006-33443836-C-T16.44e-7-4.697Likely Benign0.363AmbiguousLikely Benign0.126Likely Benign-2.78Deleterious0.960Probably Damaging0.604Possibly Damaging2.74Benign0.03Affected3.7750.21990.6347-3-35.416.04
c.3433A>C
N1145H
2D
AIThe SynGAP1 missense variant N1145H is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while polyPhen‑2 (HumDiv and HumVar) and SIFT predict pathogenic. Grouping by consensus, the benign‑predicting tools outnumber the pathogenic ones. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized scores benign, and the SGM Consensus—derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also indicates a likely benign outcome. Foldetta results are unavailable. Overall, the computational evidence supports a benign classification for the variant, and this is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.722723Binding0.2840.8501.000-2.974Likely Benign0.187Likely BenignLikely Benign0.391Likely Benign-2.42Neutral0.999Probably Damaging0.998Probably Damaging5.41Benign0.02Affected0.15200.7233210.323.04
c.3433A>G
N1145D
2D
AIThe SynGAP1 missense variant N1145D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and AlphaMissense‑Default predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.722723Binding0.2840.8501.000-3.053Likely Benign0.682Likely PathogenicLikely Benign0.332Likely Benign-2.04Neutral0.997Probably Damaging0.992Probably Damaging5.57Benign0.08Tolerated0.20820.3956210.00.98
c.3433A>T
N1145Y
2D
AIThe SynGAP1 missense variant N1145Y is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include ESM1b, FATHMM, and AlphaMissense‑Optimized, whereas REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), and SIFT uniformly predict a pathogenic impact. AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields benign, while Foldetta results are unavailable. Overall, the majority of conventional tools predict pathogenicity, but the high‑accuracy consensus leans benign. Based on the collective evidence, the variant is most likely pathogenic, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.922952Disordered0.722723Binding0.2840.8501.000-2.945Likely Benign0.451AmbiguousLikely Benign0.543Likely Pathogenic-4.07Deleterious0.999Probably Damaging0.998Probably Damaging5.40Benign0.01Affected0.06220.6337-2-22.249.07
c.3434A>C
N1145T
2D
AIThe SynGAP1 missense variant N1145T is reported in gnomAD (ID 6‑33444469‑A‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) predict the variant to be pathogenic. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta’s protein‑folding stability analysis is unavailable. Overall, the preponderance of evidence points to a benign impact for N1145T, and this conclusion does not contradict any ClinVar status, as none is currently assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.722723Binding0.2840.8501.0006-33444469-A-C16.20e-7-1.915Likely Benign0.217Likely BenignLikely Benign0.403Likely Benign-2.17Neutral0.997Probably Damaging0.992Probably Damaging5.45Benign0.07Tolerated4.3240.14180.7209002.8-13.00
c.3434A>G
N1145S
2D
AIThe SynGAP1 missense variant N1145S is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33444469‑A‑G). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). In contrast, PolyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.722723Binding0.2840.8501.000Uncertain 16-33444469-A-G21.24e-6-0.989Likely Benign0.126Likely BenignLikely Benign0.308Likely Benign-1.15Neutral0.997Probably Damaging0.989Probably Damaging5.55Benign0.89Tolerated4.3240.40780.6708112.7-27.03
c.3434A>T
N1145I
2D
AIThe SynGAP1 missense variant N1145I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools cluster into two groups: pathogenic predictions come from REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; benign predictions come from ESM1b, FATHMM, and AlphaMissense‑Optimized. AlphaMissense‑Default is uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign, while Foldetta results are unavailable. Overall, the majority of conventional predictors indicate pathogenicity, whereas the high‑accuracy subset leans benign. Based on the aggregate evidence, the variant is most likely pathogenic, and this assessment does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.922952Disordered0.722723Binding0.2840.8501.000-3.172Likely Benign0.378AmbiguousLikely Benign0.504Likely Pathogenic-4.19Deleterious0.999Probably Damaging0.998Probably Damaging5.41Benign0.00Affected0.07200.6145-2-38.0-0.94
c.3435C>A
N1145K
2D
AIThe SynGAP1 missense variant N1145K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as “Uncertain” and the SGM‑Consensus as “Likely Benign”; Foldetta results are unavailable. Overall, the balance of evidence leans toward a benign interpretation, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.722723Binding0.2840.8501.000-2.545Likely Benign0.814Likely PathogenicAmbiguous0.440Likely Benign-2.40Neutral0.997Probably Damaging0.995Probably Damaging5.50Benign0.03Affected0.19590.601810-0.414.07
c.3435C>G
N1145K
2D
AIThe SynGAP1 missense variant N1145K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), which collectively suggest a likely benign impact. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The high‑accuracy AlphaMissense‑Optimized result is uncertain, and Foldetta stability analysis is unavailable. Overall, the balance of evidence leans toward a benign interpretation, with no conflict with ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.722723Binding0.2840.8501.000-2.545Likely Benign0.814Likely PathogenicAmbiguous0.440Likely Benign-2.40Neutral0.997Probably Damaging0.995Probably Damaging5.50Benign0.03Affected0.19590.601810-0.414.07
c.3271C>A
L1091I
2D
AIThe SynGAP1 missense variant L1091I is reported in gnomAD (ID 6‑33443823‑C‑A) but has no ClinVar entry. Across the available in‑silico predictors, every tool classified the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all returned benign scores. No tool predicted pathogenicity, so the pathogenic‑prediction group is empty. High‑accuracy assessments reinforce this benign view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available for this variant. Overall, the computational evidence strongly supports a benign effect, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.924947Disordered0.984454Binding0.3760.8891.0006-33443823-C-A-4.304Likely Benign0.273Likely BenignLikely Benign0.057Likely Benign-0.66Neutral0.186Benign0.055Benign2.55Benign0.13Tolerated3.7750.10730.3911220.70.00
c.3271C>G
L1091V
2D
AIThe SynGAP1 missense variant L1091V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only polyPhen‑2 HumDiv indicates a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign and the SGM‑Consensus also reports Likely Benign; Foldetta results are not available. Overall, the consensus of the available predictions points to a benign effect, and this conclusion is consistent with the lack of ClinVar evidence, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.924947Disordered0.984454Binding0.3760.8891.000-4.587Likely Benign0.328Likely BenignLikely Benign0.048Likely Benign-0.62Neutral0.779Possibly Damaging0.211Benign2.57Benign0.08Tolerated0.15600.3561210.4-14.03
c.3272T>A
L1091Q
2D
AIThe SynGAP1 missense variant L1091Q is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, and ESM1b, whereas those that agree on a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments are less definitive: AlphaMissense‑Optimized is uncertain; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 pathogenic vs 2 benign), and Foldetta results are unavailable. Overall, the majority of available predictions (five pathogenic vs three benign) lean toward a pathogenic impact. Thus, the variant is most likely pathogenic based on current computational evidence, and this assessment does not contradict any ClinVar status because the variant has not yet been reported there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.924947Disordered0.984454Binding0.3760.8891.000-4.381Likely Benign0.854Likely PathogenicAmbiguous0.155Likely Benign-1.32Neutral0.997Probably Damaging0.939Probably Damaging2.47Pathogenic0.02Affected0.11920.1514-2-2-7.314.97
c.3272T>C
L1091P
2D
AIThe SynGAP1 missense variant L1091P is listed in gnomAD (ID 6‑33443824‑T‑C) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, and ESM1b, while pathogenic predictions are reported by polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. AlphaMissense‑Optimized returns an uncertain result, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is a 2‑vs‑2 tie, leaving it inconclusive. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of tools (five pathogenic vs three benign) predict a deleterious effect, and the high‑accuracy AlphaMissense‑Optimized score is uncertain. Consequently, the variant is most likely pathogenic based on current predictions, and this assessment does not contradict any ClinVar status, as none is reported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.924947Disordered0.984454Binding0.3760.8891.0006-33443824-T-C-4.139Likely Benign0.871Likely PathogenicAmbiguous0.180Likely Benign-1.25Neutral0.997Probably Damaging0.939Probably Damaging2.45Pathogenic0.04Affected3.7750.31990.1918-3-3-5.4-16.04
c.3272T>G
L1091R
2D
AIThe SynGAP1 missense variant L1091R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, and ESM1b, whereas those that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. The high‑accuracy AlphaMissense‑Optimized tool returns an uncertain result, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 pathogenic vs. 2 benign). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of consensus tools (five pathogenic vs. three benign) suggest a pathogenic impact. Thus, the variant is most likely pathogenic based on current predictions, and this assessment does not contradict any ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.924947Disordered0.984454Binding0.3760.8891.000-3.662Likely Benign0.896Likely PathogenicAmbiguous0.191Likely Benign-1.51Neutral0.997Probably Damaging0.939Probably Damaging2.47Pathogenic0.02Affected0.12740.1357-3-2-8.343.03
c.3274T>A
L1092M
2D
AIThe SynGAP1 missense variant L1092M is not reported in ClinVar and has no entries in gnomAD, indicating it has not been catalogued in these databases. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the substitution as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default tool remains uncertain, and no Foldetta stability assessment is available. High‑accuracy predictions from AlphaMissense‑Optimized and the SGM‑Consensus both support a benign outcome, whereas the absence of a Foldetta result precludes a stability‑based conclusion. Overall, the majority of evidence points to a benign effect for the variant, and this assessment does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.924947Disordered0.985431Binding0.3850.8901.000-5.348Likely Benign0.383AmbiguousLikely Benign0.083Likely Benign-0.15Neutral0.986Probably Damaging0.875Possibly Damaging2.66Benign0.21Tolerated0.09190.447942-1.918.03
c.3274T>G
L1092V
2D
AIThe SynGAP1 missense variant L1092V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The high‑accuracy consensus (SGM‑Consensus) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.924947Disordered0.985431Binding0.3850.8901.000-4.906Likely Benign0.451AmbiguousLikely Benign0.034Likely Benign-0.36Neutral0.051Benign0.037Benign2.79Benign0.37Tolerated0.16580.3912210.4-14.03
c.3275T>C
L1092S
2D
AIThe SynGAP1 missense variant L1092S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, SGM‑Consensus as likely benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for this variant. This conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.924947Disordered0.985431Binding0.3850.8901.000-3.649Likely Benign0.900Likely PathogenicAmbiguous0.121Likely Benign-0.42Neutral0.986Probably Damaging0.823Possibly Damaging2.68Benign0.25Tolerated0.30860.1119-3-2-4.6-26.08
c.3275T>G
L1092W
2D
AIThe SynGAP1 missense variant L1092W is not reported in ClinVar (ClinVar status: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, and FATHMM, while those that agree on a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. Two tools give uncertain results: ESM1b and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta is unavailable. Overall, the majority of conventional tools predict pathogenicity, but the high‑accuracy consensus leans toward a benign interpretation. Thus, the variant is most likely benign based on the most reliable predictions, and this conclusion does not contradict the absence of a ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.924947Disordered0.985431Binding0.3850.8901.000-7.014In-Between0.804Likely PathogenicAmbiguous0.120Likely Benign-2.00Neutral0.999Probably Damaging0.968Probably Damaging2.58Benign0.03Affected0.07870.4033-2-2-4.773.05
c.3276G>C
L1092F
2D
AIThe SynGAP1 missense variant L1092F is reported in gnomAD (6‑33443828‑G‑C) but has no ClinVar entry. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.924947Disordered0.985431Binding0.3850.8901.0006-33443828-G-C16.40e-7-5.010Likely Benign0.623Likely PathogenicLikely Benign0.067Likely Benign-1.40Neutral0.986Probably Damaging0.823Possibly Damaging2.63Benign0.18Tolerated3.7750.07720.406002-1.034.02
c.3276G>T
L1092F
2D
AIThe SynGAP1 missense variant L1092F is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools show a split: benign calls from REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, whereas pathogenic calls come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, indicates a likely benign outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also leans benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this conclusion is consistent with the lack of ClinVar annotation and gnomAD absence. Therefore, the variant is most likely benign, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.924947Disordered0.985431Binding0.3850.8901.000-5.010Likely Benign0.623Likely PathogenicLikely Benign0.067Likely Benign-1.40Neutral0.986Probably Damaging0.823Possibly Damaging2.63Benign0.18Tolerated3.7750.07720.406002-1.034.02
c.2206C>A
R736S
2D
AIThe SynGAP1 missense variant R736S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools (polyPhen‑2 HumDiv and SIFT) predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.415259Uncertain0.3050.7710.875-3.864Likely Benign0.223Likely BenignLikely Benign0.073Likely Benign-1.17Neutral0.653Possibly Damaging0.361Benign2.63Benign0.00Affected0.34220.21630-13.7-69.11
c.2206C>G
R736G
2D
AIThe SynGAP1 missense variant R736G is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv and SIFT predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. Therefore, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.415259Uncertain0.3050.7710.875-4.100Likely Benign0.121Likely BenignLikely Benign0.089Likely Benign-2.05Neutral0.653Possibly Damaging0.361Benign2.51Benign0.00Affected0.37080.2554-3-24.1-99.14
c.2206C>T
R736C
2D
AISynGAP1 missense variant R736C is listed in ClinVar with an uncertain significance and is present in gnomAD (ID 6‑33441671‑C‑T). Functional prediction tools cluster into two groups: benign predictions from REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized; pathogenic predictions from polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM, while ESM1b remains uncertain. High‑accuracy assessments reinforce the benign trend: AlphaMissense‑Optimized scores benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also returns benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence indicates a benign effect, which does not conflict with the ClinVar uncertain designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.926919Disordered0.415259Uncertain0.3050.7710.875Conflicting 36-33441671-C-T84.96e-6-7.113In-Between0.120Likely BenignLikely Benign0.190Likely Benign-2.06Neutral0.999Probably Damaging0.825Possibly Damaging2.48Pathogenic0.00Affected4.0730.37400.1691-4-37.0-53.05
c.2207G>A
R736H
2D
AIThe SynGAP1 missense variant R736H is listed in ClinVar (ID 1351080.0) with an “Uncertain” status and is present in gnomAD (variant ID 6‑33441672‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign. Foldetta results are not available. Overall, the majority of computational evidence indicates a benign impact, and this does not contradict the ClinVar “Uncertain” classification. Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.415259Uncertain0.3050.7710.875Uncertain 16-33441672-G-A63.72e-6-5.409Likely Benign0.067Likely BenignLikely Benign0.029Likely Benign-0.12Neutral0.004Benign0.001Benign2.50Benign0.00Affected4.0730.28460.0921201.3-19.05
c.2207G>C
R736P
2D
AIThe SynGAP1 missense variant R736P is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the overall assessment. Overall, the majority of evidence points to a benign effect for R736P, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.415259Uncertain0.3050.7710.875-5.246Likely Benign0.152Likely BenignLikely Benign0.085Likely Benign-1.83Neutral0.966Probably Damaging0.638Possibly Damaging2.50Benign0.00Affected0.23960.32370-22.9-59.07
c.2207G>T
R736L
2D
AIThe SynGAP1 missense variant R736L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools (polyPhen‑2 HumDiv and SIFT) predict pathogenicity, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods points to a benign classification, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.415259Uncertain0.3050.7710.875-4.173Likely Benign0.133Likely BenignLikely Benign0.061Likely Benign-1.27Neutral0.653Possibly Damaging0.361Benign2.60Benign0.00Affected0.18560.3180-3-28.3-43.03
c.2389C>A
P797T
2D
AIThe SynGAP1 missense variant P797T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.926919Disordered0.449970Uncertain0.5610.9020.875-6.554Likely Benign0.064Likely BenignLikely Benign0.030Likely Benign-0.15Neutral0.901Possibly Damaging0.708Possibly Damaging4.23Benign0.24Tolerated0.17330.58300-10.93.99
c.2389C>G
P797A
2D
AIThe SynGAP1 missense variant P797A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign. Foldetta results are not available, so they do not influence the assessment. Overall, the majority of evidence indicates that P797A is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.926919Disordered0.449970Uncertain0.5610.9020.875-5.548Likely Benign0.050Likely BenignLikely Benign0.037Likely Benign-0.33Neutral0.649Possibly Damaging0.535Possibly Damaging4.25Benign0.54Tolerated0.37040.48321-13.4-26.04
c.2389C>T
P797S
2D
AIThe SynGAP1 missense variant P797S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as tolerated or benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports it as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect for P797S, and this conclusion is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign, and this assessment does not contradict ClinVar.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.926919Disordered0.449970Uncertain0.5610.9020.875-6.232Likely Benign0.068Likely BenignLikely Benign0.029Likely Benign-0.14Neutral0.901Possibly Damaging0.637Possibly Damaging4.25Benign0.38Tolerated0.36340.52281-10.8-10.04
c.2390C>A
P797Q
2D
AIThe SynGAP1 missense variant P797Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. Thus, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.926919Disordered0.449970Uncertain0.5610.9020.875-6.201Likely Benign0.081Likely BenignLikely Benign0.066Likely Benign-0.04Neutral0.940Possibly Damaging0.801Possibly Damaging4.23Benign0.15Tolerated0.16360.47870-1-1.931.01
c.2390C>G
P797R
2D
AIThe SynGAP1 missense variant P797R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate a benign effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports “Likely Benign.” No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome; Foldetta results are not available. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.926919Disordered0.449970Uncertain0.5610.9020.875-5.642Likely Benign0.179Likely BenignLikely Benign0.045Likely Benign0.00Neutral0.006Benign0.026Benign4.28Benign0.20Tolerated0.15490.30850-2-2.959.07
c.2390C>T
P797L
2D
AIThe SynGAP1 missense variant P797L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.926919Disordered0.449970Uncertain0.5610.9020.875-5.631Likely Benign0.072Likely BenignLikely Benign0.033Likely Benign-0.66Neutral0.818Possibly Damaging0.637Possibly Damaging4.23Benign0.40Tolerated0.25500.6538-3-35.416.04
c.3100C>A
P1034T
2D
AIThe SynGAP1 missense variant P1034T is not reported in ClinVar and has no entry in gnomAD, indicating it is not catalogued in these databases. Prediction tools largely agree on a benign effect: SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only two tools predict a pathogenic outcome: SIFT and FATHMM. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of predictions support a benign impact, and this is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.991713Binding0.3430.7520.625-4.367Likely Benign0.285Likely BenignLikely Benign0.026Likely Benign-2.00Neutral0.126Benign0.096Benign2.44Pathogenic0.03Affected0.15180.66200-10.93.99
c.3100C>G
P1034A
2D
AIThe SynGAP1 missense variant P1034A is listed in ClinVar as Benign (ClinVar ID 1901716.0) and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only FATHMM predicts a pathogenic outcome, representing the sole discordant signal. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the consensus of the majority of tools, including the high‑accuracy methods, indicates a benign impact. This prediction aligns with the ClinVar status, with no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.991713Binding0.3430.7520.625Benign 1-4.174Likely Benign0.178Likely BenignLikely Benign0.060Likely Benign-2.44Neutral0.059Benign0.061Benign2.47Pathogenic0.06Tolerated3.7750.30280.56221-13.4-26.04
c.3100C>T
P1034S
2D
AIThe SynGAP1 missense variant P1034S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for P1034S, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.991713Binding0.3430.7520.625-3.730Likely Benign0.262Likely BenignLikely Benign0.054Likely Benign-2.28Neutral0.011Benign0.015Benign2.44Pathogenic0.05Affected0.30440.58531-10.8-10.04
c.3101C>A
P1034H
2D
AIThe SynGAP1 missense variant P1034H is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicting benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) predicts pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of predictions (five pathogenic vs. three benign) lean toward pathogenicity, and this conclusion does not contradict the lack of ClinVar annotation. Thus, the variant is most likely pathogenic based on current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.926919Disordered0.991713Binding0.3430.7520.625-4.634Likely Benign0.540AmbiguousLikely Benign0.083Likely Benign-3.17Deleterious0.938Possibly Damaging0.750Possibly Damaging2.38Pathogenic0.02Affected0.17760.54510-2-1.640.02
c.3101C>G
P1034R
2D
AIThe SynGAP1 P1034R variant has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, SIFT, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, while the SGM Consensus (a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports it as Likely Pathogenic; Foldetta stability analysis is unavailable. Overall, the predictions are mixed, with a slight tilt toward pathogenicity due to the SGM Consensus result and the number of pathogenic calls. The variant is most likely pathogenic based on the current computational evidence, and this assessment does not contradict ClinVar status, as no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.926919Disordered0.991713Binding0.3430.7520.625-3.666Likely Benign0.676Likely PathogenicLikely Benign0.073Likely Benign-3.04Deleterious0.002Benign0.005Benign2.40Pathogenic0.02Affected0.13660.41820-2-2.959.07
c.3101C>T
P1034L
2D
AIThe SynGAP1 missense variant P1034L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Tools that predict a pathogenic effect are PROVEAN and SIFT, while AlphaMissense‑Default is uncertain. The high‑accuracy AlphaMissense‑Optimized model classifies the variant as benign. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also yields a benign prediction (2 benign vs. 1 pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that P1034L is most likely benign, and this assessment does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.926919Disordered0.991713Binding0.3430.7520.625-4.204Likely Benign0.449AmbiguousLikely Benign0.067Likely Benign-3.24Deleterious0.001Benign0.005Benign2.53Benign0.01Affected0.22670.6937-3-35.416.04
c.3286G>A
E1096K
2D
AIThe SynGAP1 missense variant E1096K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, and the SGM‑Consensus remains Likely Benign; Foldetta results are unavailable. Overall, the balance of evidence leans toward a benign interpretation, with no conflict with ClinVar status because no ClinVar assertion exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.976475Binding0.3080.8581.000-4.148Likely Benign0.845Likely PathogenicAmbiguous0.097Likely Benign-1.44Neutral0.872Possibly Damaging0.478Possibly Damaging2.75Benign0.15Tolerated0.24400.753301-0.4-0.94
c.3286G>C
E1096Q
2D
AIThe SynGAP1 missense variant E1096Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (both HumDiv and HumVar) predict a pathogenic outcome. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as likely benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from multiple prediction algorithms and high‑accuracy tools suggests that E1096Q is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.976475Binding0.3080.8581.000-3.134Likely Benign0.462AmbiguousLikely Benign0.142Likely Benign-1.08Neutral0.954Possibly Damaging0.654Possibly Damaging2.73Benign0.29Tolerated0.15270.7459220.0-0.98
c.3287A>C
E1096A
2D
AIThe SynGAP1 missense variant E1096A is listed in ClinVar (ID 2579889.0) with an uncertain significance annotation and is not reported in gnomAD. Consensus from multiple in‑silico predictors shows a predominance of benign calls: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only polyPhen‑2 HumDiv assigns a pathogenic label, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign; Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the aggregate evidence points to a benign effect, which is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.976475Binding0.3080.8581.000Uncertain 1-4.504Likely Benign0.510AmbiguousLikely Benign0.164Likely Benign-1.37Neutral0.626Possibly Damaging0.184Benign2.77Benign0.16Tolerated3.7750.38050.7569-105.3-58.04
c.3287A>G
E1096G
2D
AIThe SynGAP1 missense variant E1096G is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in silico predictors shows a split: polyPhen‑2 HumDiv and HumVar classify it as pathogenic, whereas REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized predict a benign effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign outcome, and AlphaMissense‑Optimized itself is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of high‑accuracy tools (AlphaMissense‑Optimized and SGM‑Consensus) indicate a benign impact, and no evidence contradicts this assessment with ClinVar data, which is currently lacking.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.976475Binding0.3080.8581.000-2.749Likely Benign0.536AmbiguousLikely Benign0.118Likely Benign-2.14Neutral0.872Possibly Damaging0.478Possibly Damaging2.70Benign0.06Tolerated0.27890.62200-23.1-72.06
c.3287A>T
E1096V
2D
AIThe SynGAP1 missense variant E1096V is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus, REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is Likely Benign. No Foldetta stability result is available. Overall, the majority of evidence indicates the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.976475Binding0.3080.8581.000-3.588Likely Benign0.650Likely PathogenicLikely Benign0.138Likely Benign-1.06Neutral0.043Benign0.017Benign2.81Benign0.03Affected0.10820.7596-2-27.7-29.98
c.3288G>C
E1096D
2D
AIThe SynGAP1 missense variant E1096D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign interpretation, and this conclusion does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.976475Binding0.3080.8581.000-3.818Likely Benign0.192Likely BenignLikely Benign0.116Likely Benign-0.40Neutral0.115Benign0.052Benign2.71Benign0.38Tolerated0.20340.4994320.0-14.03
c.3288G>T
E1096D
2D
AIThe SynGAP1 missense variant E1096D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign classification, and this conclusion is not contradicted by any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.976475Binding0.3080.8581.000-3.818Likely Benign0.192Likely BenignLikely Benign0.116Likely Benign-0.40Neutral0.115Benign0.052Benign2.71Benign0.38Tolerated0.20340.4994320.0-14.03
c.3418A>C
T1140P
2D
AIThe SynGAP1 missense variant T1140P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools, polyPhen‑2 HumDiv and HumVar, predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect for T1140P, and this conclusion is consistent with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.708094Binding0.2930.8541.000-1.921Likely Benign0.126Likely BenignLikely Benign0.058Likely Benign-1.49Neutral0.761Possibly Damaging0.478Possibly Damaging2.61Benign0.32Tolerated0.20440.38370-1-0.9-3.99
c.3418A>G
T1140A
2D
AIThe SynGAP1 missense variant T1140A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.708094Binding0.2930.8541.000-3.838Likely Benign0.107Likely BenignLikely Benign0.061Likely Benign-0.36Neutral0.002Benign0.003Benign2.71Benign1.00Tolerated0.39490.3463102.5-30.03
c.3418A>T
T1140S
2D
AIThe SynGAP1 missense variant T1140S is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.708094Binding0.2930.8541.000-2.805Likely Benign0.105Likely BenignLikely Benign0.052Likely Benign-0.27Neutral0.025Benign0.010Benign3.25Benign0.91Tolerated0.34010.350411-0.1-14.03
c.3419C>A
T1140K
2D
AIThe SynGAP1 missense variant T1140K is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. The high‑accuracy consensus, SGM‑Consensus, is derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN and therefore reports a likely benign outcome. AlphaMissense‑Optimized also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence—including the high‑accuracy consensus—points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.708094Binding0.2930.8541.000-4.053Likely Benign0.657Likely PathogenicLikely Benign0.068Likely Benign-1.65Neutral0.611Possibly Damaging0.257Benign2.63Benign0.22Tolerated0.11960.29500-1-3.227.07
c.3419C>G
T1140R
2D
AIThe SynGAP1 missense variant T1140R is listed in gnomAD (ID 6‑33444454‑C‑G) but has no ClinVar entry. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.708094Binding0.2930.8541.0006-33444454-C-G16.20e-7-4.245Likely Benign0.682Likely PathogenicLikely Benign0.073Likely Benign-1.69Neutral0.761Possibly Damaging0.398Benign2.61Benign0.15Tolerated4.3240.09970.2442-1-1-3.855.08
c.3419C>T
T1140I
2D
AIThe SynGAP1 missense variant T1140I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports it as likely benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, and AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods indicates that the variant is most likely benign, with no conflict with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.708094Binding0.2930.8541.000-5.205Likely Benign0.368AmbiguousLikely Benign0.058Likely Benign-1.85Neutral0.611Possibly Damaging0.398Benign2.61Benign0.08Tolerated0.09480.46480-15.212.05
c.3208A>G
R1070G
2D
AIThe SynGAP1 missense variant R1070G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Consensus from standard in silico predictors shows five tools (REVEL, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized) classifying it as benign, while four (PROVEAN, polyPhen‑2 HumDiv, SIFT, AlphaMissense‑Default) predict pathogenicity. High‑accuracy assessments give a benign result from AlphaMissense‑Optimized; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (2 vs 2), and Foldetta data are unavailable. Overall, the balance of evidence leans toward a benign effect. This conclusion does not conflict with ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.930790Disordered0.982693Binding0.2970.9060.875-4.731Likely Benign0.568Likely PathogenicLikely Benign0.149Likely Benign-2.88Deleterious0.789Possibly Damaging0.258Benign3.75Benign0.01Affected0.31500.4070-3-24.1-99.14
c.3208A>T
R1070W
2D
AIThe SynGAP1 missense variant R1070W is not reported in ClinVar and is absent from gnomAD. Prediction tools cluster into two groups: benign predictions come from REVEL, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions come from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and the SGM‑Consensus score (Likely Pathogenic). High‑accuracy assessments show AlphaMissense‑Optimized labeling the variant as benign, whereas the SGM‑Consensus (a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates it is likely pathogenic. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this residue. Overall, the majority of tools and the SGM‑Consensus support a pathogenic effect, so the variant is most likely pathogenic, and this assessment does not contradict any ClinVar annotation because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.930790Disordered0.982693Binding0.2970.9060.875-8.063Likely Pathogenic0.743Likely PathogenicLikely Benign0.139Likely Benign-3.42Deleterious0.999Probably Damaging0.956Probably Damaging3.72Benign0.00Affected0.11950.42932-33.630.03
c.3209G>A
R1070K
2D
AIThe SynGAP1 missense variant R1070K is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. All evaluated in‑silico predictors agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” High‑accuracy tools reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta results are unavailable. Based on the unanimous benign predictions, the variant is most likely benign, and this assessment does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.982693Binding0.2970.9060.875Conflicting 2-5.093Likely Benign0.326Likely BenignLikely Benign0.104Likely Benign-1.42Neutral0.049Benign0.048Benign3.86Benign0.09Tolerated3.7750.49970.4867320.6-28.01
c.3209G>C
R1070T
2D
AIThe SynGAP1 missense variant R1070T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as “Uncertain” and the SGM‑Consensus as “Likely Benign”; Foldetta results are not available. Overall, the balance of evidence leans toward a benign impact, with no ClinVar entry to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.982693Binding0.2970.9060.875-5.093Likely Benign0.860Likely PathogenicAmbiguous0.144Likely Benign-2.35Neutral0.948Possibly Damaging0.507Possibly Damaging3.78Benign0.01Affected3.7750.16340.4727-1-13.8-55.08
c.3209G>T
R1070M
2D
AIThe SynGAP1 missense variant R1070M is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the balance of evidence, including the consensus benign call and the absence of pathogenic predictions from the most reliable tools, suggests the variant is most likely benign. This conclusion does not contradict ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.982693Binding0.2970.9060.875-6.455Likely Benign0.917Likely PathogenicAmbiguous0.183Likely Benign-2.27Neutral0.995Probably Damaging0.907Possibly Damaging3.74Benign0.00Affected0.16610.43240-16.4-24.99
c.3209_3210delinsCA
R1070T
2D
AIThe SynGAP1 missense variant R1070T is listed in ClinVar (ID 2759838.0) with an “Uncertain” clinical significance and is not reported in gnomAD. Prediction tools that agree on a benign effect include PROVEAN, ESM1b, FATHMM, and the SGM‑Consensus (which aggregates these three benign calls with the pathogenic AlphaMissense‑Default to yield a Likely Benign verdict). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. AlphaMissense‑Optimized returns an uncertain result. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Benign, and no Foldetta stability data is available. Overall, the balance of evidence leans toward a benign impact, which is consistent with the ClinVar “Uncertain” status and does not contradict it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.982693Binding0.2970.9060.875Uncertain 1-5.093Likely Benign0.860Likely PathogenicAmbiguous-2.35Neutral0.948Possibly Damaging0.507Possibly Damaging3.78Benign0.01Affected3.7750.16340.4727-1-13.8-55.08
c.3210G>C
R1070S
2D
AIThe SynGAP1 missense variant R1070S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, and FATHMM. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, while Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. Thus, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.982693Binding0.2970.9060.875-4.311Likely Benign0.913Likely PathogenicAmbiguous0.091Likely Benign-2.07Neutral0.789Possibly Damaging0.258Benign3.85Benign0.01Affected0.26400.40420-13.7-69.11
c.3210G>T
R1070S
2D
AIThe SynGAP1 missense variant R1070S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, and FATHMM. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, SGM‑Consensus as likely benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.982693Binding0.2970.9060.875-4.311Likely Benign0.913Likely PathogenicAmbiguous0.091Likely Benign-2.07Neutral0.789Possibly Damaging0.258Benign3.85Benign0.01Affected0.26400.40420-13.7-69.11
c.3220C>A
Q1074K
2D
AIThe SynGAP1 missense variant Q1074K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only AlphaMissense‑Default predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as likely benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for this variant, and this conclusion is consistent with the lack of any ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.987006Binding0.3390.8970.750-6.162Likely Benign0.712Likely PathogenicLikely Benign0.110Likely Benign-0.88Neutral0.011Benign0.006Benign2.75Benign0.36Tolerated0.18650.460011-0.40.04
c.3220C>G
Q1074E
2D
AIThe SynGAP1 missense variant Q1074E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions strongly suggests that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.987006Binding0.3390.8970.750-2.815Likely Benign0.419AmbiguousLikely Benign0.096Likely Benign-0.79Neutral0.264Benign0.103Benign2.79Benign0.24Tolerated0.13860.2856220.00.98
c.3221A>C
Q1074P
2D
AIThe SynGAP1 missense variant Q1074P is listed in gnomAD (ID 6‑33443773‑A‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign or tolerated. Only polyPhen‑2 HumDiv flags it as pathogenic, creating a single outlier. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.987006Binding0.3390.8970.7506-33443773-A-C16.23e-7-4.259Likely Benign0.083Likely BenignLikely Benign0.188Likely Benign0.52Neutral0.925Possibly Damaging0.432Benign2.66Benign0.13Tolerated3.7750.20460.5784-101.9-31.01
c.3221A>G
Q1074R
2D
AIThe SynGAP1 missense variant Q1074R is listed in gnomAD (ID 6‑33443773‑A‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only AlphaMissense‑Default predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar status (none reported). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.987006Binding0.3390.8970.7506-33443773-A-G-5.710Likely Benign0.594Likely PathogenicLikely Benign0.124Likely Benign-0.54Neutral0.292Benign0.157Benign2.70Benign0.28Tolerated3.7750.15230.264311-1.028.06
c.3221A>T
Q1074L
2D
AIThe SynGAP1 missense variant Q1074L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.987006Binding0.3390.8970.750-3.561Likely Benign0.259Likely BenignLikely Benign0.118Likely Benign-1.29Neutral0.625Possibly Damaging0.266Benign2.68Benign1.00Tolerated0.08400.6293-2-27.3-14.97
c.3222G>C
Q1074H
2D
AIThe SynGAP1 missense variant Q1074H is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools uniformly favor a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity, and the only uncertain call comes from AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports the variant as “Likely Benign.” High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.987006Binding0.3390.8970.750-5.051Likely Benign0.381AmbiguousLikely Benign0.053Likely Benign-0.12Neutral0.006Benign0.008Benign2.67Benign0.07Tolerated0.14360.4407300.39.01
c.3222G>T
Q1074H
2D
AIThe SynGAP1 missense variant Q1074H is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools uniformly favor a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity, and the only uncertain call comes from AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports the variant as “Likely Benign.” High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.987006Binding0.3390.8970.750-5.051Likely Benign0.381AmbiguousLikely Benign0.053Likely Benign-0.12Neutral0.006Benign0.008Benign2.67Benign0.07Tolerated0.14360.4407300.39.01
c.3421C>A
P1141T
2D
AIThe SynGAP1 missense variant P1141T is not reported in ClinVar (ClinVar status: not reported) and is absent from gnomAD (gnomAD: not present). Prediction tools that agree on a benign effect include REVEL, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (two benign vs. two pathogenic). High‑accuracy methods give AlphaMissense‑Optimized a benign prediction; the SGM Consensus remains inconclusive, and Foldetta (combining FoldX‑MD and Rosetta) has no available result. Overall, the balance of evidence, particularly the benign call from the high‑accuracy AlphaMissense‑Optimized model, suggests that the variant is most likely benign, and this assessment does not contradict the current ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.930790Disordered0.716087Binding0.3640.8521.000-4.090Likely Benign0.176Likely BenignLikely Benign0.106Likely Benign-3.85Deleterious0.856Possibly Damaging0.723Possibly Damaging0.98Pathogenic0.00Affected0.15940.61450-10.93.99
c.3421C>G
P1141A
2D
AIThe SynGAP1 missense variant P1141A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. The SGM Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive because it yields a 2‑to‑2 split. Foldetta, a protein‑folding‑stability method that combines FoldX‑MD and Rosetta outputs, has no available result for this variant. High‑accuracy tools therefore provide mixed evidence: AlphaMissense‑Optimized indicates benign, while the consensus and stability analyses are unavailable. Overall, the majority of individual predictors (five versus four) favor a pathogenic interpretation, and this does not contradict any ClinVar annotation because none exists. Thus, the variant is most likely pathogenic based on current computational predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.930790Disordered0.716087Binding0.3640.8521.000-3.885Likely Benign0.120Likely BenignLikely Benign0.076Likely Benign-3.67Deleterious0.856Possibly Damaging0.492Possibly Damaging1.00Pathogenic0.00Affected0.35250.51351-13.4-26.04
c.3421C>T
P1141S
2D
AIThe SynGAP1 missense variant P1141S is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. The SGM Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (2 benign vs 2 pathogenic). Foldetta results are unavailable. Overall, five of the nine evaluated tools predict pathogenicity while four predict benignity, giving a slight majority toward a deleterious effect. Thus, the variant is most likely pathogenic based on current computational predictions, and this assessment does not contradict any ClinVar status because the variant has not yet been reported there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.930790Disordered0.716087Binding0.3640.8521.000-2.574Likely Benign0.187Likely BenignLikely Benign0.094Likely Benign-3.58Deleterious0.856Possibly Damaging0.492Possibly Damaging0.99Pathogenic0.00Affected0.33790.55661-10.8-10.04
c.3422C>A
P1141Q
2D
AIThe SynGAP1 missense variant P1141Q is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 benign vs 2 pathogenic), and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.930790Disordered0.716087Binding0.3640.8521.000-4.331Likely Benign0.274Likely BenignLikely Benign0.136Likely Benign-2.72Deleterious0.074Benign0.047Benign0.97Pathogenic0.00Affected0.14490.51860-1-1.931.01
c.3422C>G
P1141R
2D
AIThe SynGAP1 missense variant P1141R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect comprise PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM‑Consensus indicates a likely pathogenic outcome; a Foldetta stability analysis is unavailable. Overall, the majority of computational predictions (seven pathogenic vs. three benign) support a pathogenic classification. This consensus does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.930790Disordered0.716087Binding0.3640.8521.000-4.768Likely Benign0.626Likely PathogenicLikely Benign0.120Likely Benign-3.90Deleterious0.913Possibly Damaging0.690Possibly Damaging0.97Pathogenic0.00Affected0.13290.36140-2-2.959.07
c.3422C>T
P1141L
2D
AIThe SynGAP1 missense variant P1141L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicting benign, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—leans pathogenic (two pathogenic versus one benign). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from both general and high‑accuracy tools indicates that P1141L is most likely pathogenic, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.930790Disordered0.716087Binding0.3640.8521.000-3.817Likely Benign0.352AmbiguousLikely Benign0.110Likely Benign-4.64Deleterious0.954Possibly Damaging0.759Possibly Damaging0.98Pathogenic0.00Affected0.21470.6099-3-35.416.04
c.3985C>A
L1329M
2D
AIThe SynGAP1 missense change L1329M is recorded in gnomAD (ID 6‑33451859‑C‑A) but has no ClinVar entry. Functional prediction tools split into two consensus groups: benign‑predicted by REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized; pathogenic‑predicted by polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized scores benign, and the SGM‑Consensus likewise indicates benign. Foldetta, a protein‑folding stability predictor combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.924905Binding0.3360.7480.8756-33451859-C-A-5.493Likely Benign0.780Likely PathogenicLikely Benign0.087Likely Benign-1.16Neutral0.994Probably Damaging0.990Probably Damaging3.10Benign0.00Affected3.7750.09140.427324-1.918.03
c.3985C>G
L1329V
2D
AIThe SynGAP1 missense variant L1329V is catalogued in gnomAD (6‑33451859‑C‑G) but has no ClinVar entry. Functional prediction tools show mixed results: benign calls come from REVEL, PROVEAN, ESM1b, and FATHMM, whereas pathogenic calls are reported by polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. When predictions are grouped by consensus, the majority of standard algorithms (REVEL, PROVEAN, ESM1b, FATHMM) support a benign effect, while a minority (polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default) suggest pathogenicity. High‑accuracy assessments further clarify the picture: AlphaMissense‑Optimized predicts a benign outcome, and the SGM‑Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also favors benign. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign effect, and this conclusion is consistent with the lack of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.924905Binding0.3360.7480.8756-33451859-C-G16.40e-7-4.209Likely Benign0.770Likely PathogenicLikely Benign0.077Likely Benign-1.55Neutral0.980Probably Damaging0.952Probably Damaging3.18Benign0.00Affected3.7750.15710.3579120.4-14.03
c.3986T>A
L1329Q
2D
AIThe SynGAP1 missense variant L1329Q is reported in gnomAD (ID 6‑33451860‑T‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, ESM1b, and FATHMM, whereas pathogenic predictions are made by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as pathogenic; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive, and Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a deleterious effect, indicating that the variant is most likely pathogenic, and this assessment does not contradict any ClinVar status because none is available.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.930790Disordered0.924905Binding0.3360.7480.8756-33451860-T-A-4.106Likely Benign0.956Likely PathogenicLikely Pathogenic0.157Likely Benign-3.31Deleterious0.994Probably Damaging0.993Probably Damaging3.05Benign0.00Affected3.7750.13820.1505-2-2-7.314.97
c.3986T>C
L1329P
2D
AIThe SynGAP1 missense variant L1329P is listed in gnomAD (ID 6‑33451860‑T‑C) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, ESM1b, and FATHMM, while pathogenic predictions are reported by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain. The SGM Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a tie and is therefore inconclusive. No Foldetta stability assessment is available. Overall, the majority of high‑confidence predictors (five pathogenic vs three benign) lean toward a pathogenic effect. Because ClinVar contains no classification, there is no conflict with existing clinical annotation. Thus, based on current in silico evidence, the variant is most likely pathogenic.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.930790Disordered0.924905Binding0.3360.7480.8756-33451860-T-C-2.903Likely Benign0.951Likely PathogenicAmbiguous0.165Likely Benign-3.74Deleterious0.994Probably Damaging0.993Probably Damaging3.04Benign0.00Affected3.7750.33960.1794-3-3-5.4-16.04
c.3986T>G
L1329R
2D
AIThe SynGAP1 missense variant L1329R is catalogued in gnomAD (ID 6‑33451860‑T‑G) but has no ClinVar submission. Functional prediction tools cluster into two groups: benign predictions from REVEL, ESM1b, and FATHMM; pathogenic predictions from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. AlphaMissense‑Optimized returns an uncertain result. The SGM Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive due to a 2‑to‑2 split. No Foldetta stability assessment is available. Overall, the majority of high‑confidence predictors (five pathogenic vs three benign) lean toward a pathogenic effect. Because ClinVar contains no classification, there is no conflict with existing clinical annotations. Thus, based on current in silico evidence, the variant is most likely pathogenic.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.930790Disordered0.924905Binding0.3360.7480.8756-33451860-T-G-3.636Likely Benign0.923Likely PathogenicAmbiguous0.141Likely Benign-3.16Deleterious0.994Probably Damaging0.990Probably Damaging3.05Benign0.00Affected3.7750.15940.1547-2-3-8.343.03
c.3997G>A
E1333K
2D
AISynGAP1 missense variant E1333K is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and FATHMM, while those that predict a pathogenic impact are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Uncertain, and Foldetta results are unavailable. Overall, the consensus of multiple benign‑predicting tools and the SGM‑Consensus suggests a benign outcome, whereas a subset of tools indicates pathogenicity. Thus, the variant is most likely benign based on the current predictions, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.953319Binding0.3470.7460.750-5.038Likely Benign0.942Likely PathogenicAmbiguous0.244Likely Benign-2.49Neutral0.980Probably Damaging0.956Probably Damaging2.84Benign0.00Affected0.27280.749101-0.4-0.94
c.3997G>C
E1333Q
2D
AIThe SynGAP1 missense variant E1333Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic impact are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (3 benign vs. 1 pathogenic votes) also indicates benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the preponderance of evidence points to a benign effect for E1333Q, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.953319Binding0.3470.7460.750-4.034Likely Benign0.746Likely PathogenicLikely Benign0.217Likely Benign-1.84Neutral0.980Probably Damaging0.968Probably Damaging2.83Benign0.00Affected0.15480.7617220.0-0.98
c.3998A>C
E1333A
2D
AIThe SynGAP1 missense variant E1333A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and FATHMM. Tools that agree on a pathogenic effect include PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. The high‑accuracy AlphaMissense‑Optimized tool returned an uncertain result, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (2 vs 2). Foldetta, which would assess protein‑folding stability, has no available output for this variant. Overall, more tools predict pathogenicity than benignity, and no ClinVar entry contradicts this assessment. Thus, the variant is most likely pathogenic based on the current computational predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.930790Disordered0.953319Binding0.3470.7460.750-3.636Likely Benign0.834Likely PathogenicAmbiguous0.254Likely Benign-3.76Deleterious0.980Probably Damaging0.956Probably Damaging2.83Benign0.00Affected0.41770.73820-15.3-58.04
c.3998A>G
E1333G
2D
AIThe SynGAP1 missense variant E1333G is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and FATHMM, whereas those that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain. High‑accuracy assessments are inconclusive: AlphaMissense‑Optimized remains uncertain; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is a 2‑vs‑2 tie and therefore unavailable; Foldetta, which would evaluate protein‑folding stability, has no result for this variant. Overall, more tools predict pathogenicity than benignity, and no ClinVar entry contradicts this assessment. Thus, the variant is most likely pathogenic based on the available predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.930790Disordered0.953319Binding0.3470.7460.750-4.504Likely Benign0.801Likely PathogenicAmbiguous0.260Likely Benign-4.31Deleterious0.994Probably Damaging0.968Probably Damaging2.83Benign0.00Affected0.31010.62170-23.1-72.06
c.3998A>T
E1333V
2D
AIThe SynGAP1 E1333V missense change is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect are REVEL, ESM1b, and FATHMM. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. High‑accuracy assessments show AlphaMissense‑Optimized predicts pathogenicity; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (two pathogenic vs two benign votes), and Foldetta results are unavailable. Overall, the majority of evidence (six pathogenic vs three benign) points to a pathogenic impact. Thus, the variant is most likely pathogenic, and this conclusion does not contradict any ClinVar status because no ClinVar assertion exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.930790Disordered0.953319Binding0.3470.7460.750-4.322Likely Benign0.974Likely PathogenicLikely Pathogenic0.289Likely Benign-4.30Deleterious0.994Probably Damaging0.981Probably Damaging2.81Benign0.00Affected0.09940.7615-2-27.7-29.98
c.3999G>C
E1333D
2D
AIThe SynGAP1 missense variant E1333D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for E1333D, and this conclusion does not contradict any ClinVar status, as none is available.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.953319Binding0.3470.7460.750-4.239Likely Benign0.651Likely PathogenicLikely Benign0.117Likely Benign-1.78Neutral0.953Possibly Damaging0.935Probably Damaging2.88Benign0.00Affected0.19890.5029320.0-14.03
c.3999G>T
E1333D
2D
AIThe SynGAP1 missense variant E1333D is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in‑silico predictors indicates a benign effect: REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all predict a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT classify the change as pathogenic, and AlphaMissense‑Default also predicts pathogenicity. High‑accuracy tools specifically give a benign prediction for AlphaMissense‑Optimized and a likely benign result for the SGM‑Consensus; Foldetta data are unavailable. Overall, the majority of evidence supports a benign interpretation, and this is consistent with the absence of a ClinVar pathogenic claim. Thus, the variant is most likely benign, and this is consistent with the lack of a ClinVar pathogenic claim.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.953319Binding0.3470.7460.750-4.239Likely Benign0.651Likely PathogenicLikely Benign0.117Likely Benign-1.78Neutral0.953Possibly Damaging0.935Probably Damaging2.88Benign0.00Affected0.19890.5029320.0-14.03
c.2386C>A
P796T
2D
AIThe SynGAP1 P796T missense variant is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. In contrast, polyPhen‑2 HumDiv and SIFT predict pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.936162Disordered0.426363Uncertain0.4270.9000.875-5.399Likely Benign0.062Likely BenignLikely Benign0.082Likely Benign-0.01Neutral0.494Possibly Damaging0.236Benign4.26Benign0.04Affected0.17050.49610-10.93.99
c.2386C>G
P796A
2D
AIThe SynGAP1 missense variant P796A is not reported in ClinVar (ClinVar ID: None) but is present in gnomAD (gnomAD ID: 6‑33442938‑C‑G). All evaluated in silico predictors classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized return benign or benign‑like scores. No tool predicts pathogenicity. Grouping by agreement, the benign‑predicting tools comprise the entire set, while no pathogenic predictions are available. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta, a protein‑folding stability method, did not provide a result for this variant. Overall, the computational evidence strongly suggests that P796A is most likely benign, and this conclusion does not contradict the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.936162Disordered0.426363Uncertain0.4270.9000.8756-33442938-C-G-6.077Likely Benign0.050Likely BenignLikely Benign0.023Likely Benign-0.31Neutral0.174Benign0.063Benign4.28Benign0.08Tolerated4.3220.35980.3776-113.4-26.04
c.2386C>T
P796S
2D
AIThe SynGAP1 missense variant P796S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) reports likely benign. Foldetta results are not available for this variant. Based on the collective evidence, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.936162Disordered0.426363Uncertain0.4270.9000.875-5.382Likely Benign0.067Likely BenignLikely Benign0.055Likely Benign0.05Neutral0.174Benign0.091Benign4.28Benign0.48Tolerated0.35600.41711-10.8-10.04
c.2387C>A
P796Q
2D
AIThe SynGAP1 missense variant P796Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign, while the only tool predicting a deleterious outcome is SIFT, which labels it pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) indicates likely benign; no Foldetta stability data are available. Overall, the consensus of the majority of predictors and the high‑accuracy tools points to a benign effect for P796Q, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation. Thus, the variant is most likely benign, and this assessment does not contradict any ClinVar classification, as no pathogenic claim is present.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.936162Disordered0.426363Uncertain0.4270.9000.875-6.575Likely Benign0.084Likely BenignLikely Benign0.074Likely Benign-0.15Neutral0.325Benign0.103Benign4.27Benign0.01Affected0.15620.41170-1-1.931.01
c.2387C>G
P796R
2D
AIThe SynGAP1 P796R missense change is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports it as “Likely Benign.” Only SIFT predicts a pathogenic outcome, and ESM1b remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Taken together, the overwhelming majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.936162Disordered0.426363Uncertain0.4270.9000.875-7.053In-Between0.191Likely BenignLikely Benign0.063Likely Benign-0.57Neutral0.002Benign0.002Benign4.28Benign0.01Affected0.15580.29340-2-2.959.07
c.2387C>T
P796L
2D
AIThe SynGAP1 P796L missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is also benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.936162Disordered0.426363Uncertain0.4270.9000.875-5.442Likely Benign0.069Likely BenignLikely Benign0.063Likely Benign-1.06Neutral0.325Benign0.182Benign4.24Benign0.01Affected0.23280.5712-3-35.416.04
c.3310C>A
P1104T
2D
AIThe SynGAP1 missense variant P1104T is reported in gnomAD (variant ID 6‑33443862‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. No Foldetta stability analysis is available, so it does not influence the conclusion. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar classification (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.936162Disordered0.954801Binding0.4400.8630.8756-33443862-C-A-3.995Likely Benign0.070Likely BenignLikely Benign0.094Likely Benign-0.14Neutral0.770Possibly Damaging0.481Possibly Damaging2.76Benign0.09Tolerated3.7750.15490.6700-100.93.99
c.3310C>G
P1104A
2D
AIThe SynGAP1 missense variant P1104A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.936162Disordered0.954801Binding0.4400.8630.875-3.677Likely Benign0.059Likely BenignLikely Benign0.041Likely Benign-0.54Neutral0.409Benign0.184Benign2.74Benign0.22Tolerated0.32890.53151-13.4-26.04
c.3310C>T
P1104S
2D
AIThe SynGAP1 missense variant P1104S is listed in ClinVar (ID 2912797.0) as Benign and is present in gnomAD (variant ID 6‑33443862‑C‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is Likely Benign, and AlphaMissense‑Optimized also reports Benign. Foldetta results are not available. Overall, the majority of computational evidence supports a benign classification, which is consistent with the ClinVar status. Thus, the variant is most likely benign and does not contradict the ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.936162Disordered0.954801Binding0.4400.8630.875Benign 16-33443862-C-T16.54e-7-2.330Likely Benign0.073Likely BenignLikely Benign0.088Likely Benign-0.30Neutral0.770Possibly Damaging0.404Benign2.77Benign0.10Tolerated3.7750.32710.5746-110.8-10.04
c.3311C>A
P1104Q
2D
AIThe SynGAP1 missense variant P1104Q is reported in gnomAD (ID 6‑33443863‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign likelihood. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is assigned).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.936162Disordered0.954801Binding0.4400.8630.8756-33443863-C-A-3.161Likely Benign0.104Likely BenignLikely Benign0.114Likely Benign-0.64Neutral0.986Probably Damaging0.825Possibly Damaging2.68Benign0.06Tolerated3.7750.14980.5063-10-1.931.01
c.3311C>G
P1104R
2D
AIThe SynGAP1 missense variant P1104R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus likewise indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.936162Disordered0.954801Binding0.4400.8630.875-3.864Likely Benign0.328Likely BenignLikely Benign0.099Likely Benign-0.64Neutral0.986Probably Damaging0.761Possibly Damaging2.68Benign0.06Tolerated0.13870.37030-2-2.959.07
c.3311C>T
P1104L
2D
AIThe SynGAP1 missense variant P1104L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only polyPhen‑2 HumDiv indicates a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also predicts Likely Benign; Foldetta results are unavailable. Overall, the consensus of the majority of tools, including the high‑accuracy predictors, points to a benign impact. This conclusion is consistent with the lack of ClinVar evidence and does not contradict any existing database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.936162Disordered0.954801Binding0.4400.8630.875-3.846Likely Benign0.096Likely BenignLikely Benign0.146Likely Benign-0.33Neutral0.626Possibly Damaging0.168Benign2.81Benign1.00Tolerated0.22640.6795-3-35.416.04
c.3112A>C
T1038P
2D
AIThe SynGAP1 missense variant T1038P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (both HumDiv and HumVar) predict a pathogenic outcome. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.982911Binding0.2790.7940.625-2.196Likely Benign0.390AmbiguousLikely Benign0.116Likely Benign-1.10Neutral0.965Probably Damaging0.611Possibly Damaging2.66Benign0.26Tolerated0.18560.46800-1-0.9-3.99
c.3112A>G
T1038A
2D
AIThe SynGAP1 missense variant T1038A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, whereas only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as likely benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the consensus of the available predictions points to a benign impact, and this is consistent with the lack of ClinVar evidence, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.982911Binding0.2790.7940.625-3.544Likely Benign0.265Likely BenignLikely Benign0.047Likely Benign-0.79Neutral0.649Possibly Damaging0.209Benign2.81Benign0.15Tolerated0.34290.3983102.5-30.03
c.3112A>T
T1038S
2D
AIThe SynGAP1 missense variant T1038S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence supports a benign classification, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.982911Binding0.2790.7940.625-2.693Likely Benign0.198Likely BenignLikely Benign0.101Likely Benign-0.17Neutral0.649Possibly Damaging0.209Benign2.98Benign0.74Tolerated0.28790.403511-0.1-14.03
c.3113C>A
T1038N
2D
AIThe SynGAP1 missense variant T1038N is not reported in ClinVar and has no entries in gnomAD, indicating it has not been catalogued in these databases. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the substitution as benign, while the majority‑vote consensus from SGM (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, and AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates likely benign. No Foldetta stability analysis is available, so folding‑stability evidence is lacking. Overall, the preponderance of computational evidence supports a benign classification for T1038N, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation. Thus, the variant is most likely benign, and this is not contradicted by ClinVar, which has no pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.982911Binding0.2790.7940.625-3.837Likely Benign0.390AmbiguousLikely Benign0.054Likely Benign-1.36Neutral0.818Possibly Damaging0.355Benign2.68Benign0.10Tolerated0.11840.449000-2.813.00
c.3113C>G
T1038S
2D
AIThe SynGAP1 missense variant T1038S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence supports a benign classification, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.982911Binding0.2790.7940.625-2.693Likely Benign0.198Likely BenignLikely Benign0.102Likely Benign-0.17Neutral0.649Possibly Damaging0.209Benign2.98Benign0.74Tolerated0.28790.403511-0.1-14.03
c.3113C>T
T1038I
2D
AIThe SynGAP1 T1038I missense variant has no ClinVar record and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), which classifies the variant as Likely Benign. Tools that predict a pathogenic outcome are polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. The high‑accuracy AlphaMissense‑Optimized score is Uncertain, and the Foldetta protein‑folding stability assessment is unavailable. Overall, the balance of evidence leans toward a benign interpretation, with one high‑accuracy tool inconclusive and no conflicting ClinVar annotation. Thus, the variant is most likely benign, and there is no ClinVar status that contradicts this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.982911Binding0.2790.7940.625-4.552Likely Benign0.877Likely PathogenicAmbiguous0.093Likely Benign-2.02Neutral0.990Probably Damaging0.637Possibly Damaging2.69Benign0.04Affected0.10120.50360-15.212.05
c.3280T>A
S1094T
2D
AIThe SynGAP1 missense variant S1094T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.981352Binding0.3580.8771.000-4.009Likely Benign0.194Likely BenignLikely Benign0.077Likely Benign-0.57Neutral0.790Possibly Damaging0.433Benign2.59Benign0.16Tolerated0.18740.6902110.114.03
c.3280T>C
S1094P
2D
AIThe SynGAP1 missense variant S1094P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for S1094P, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.981352Binding0.3580.8771.000-2.430Likely Benign0.285Likely BenignLikely Benign0.124Likely Benign-1.31Neutral0.990Probably Damaging0.798Possibly Damaging2.46Pathogenic0.13Tolerated0.23220.60991-1-0.810.04
c.3280T>G
S1094A
2D
AIThe SynGAP1 missense variant S1094A is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity, so the pathogenic‑prediction group is empty. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.981352Binding0.3580.8771.000-3.595Likely Benign0.188Likely BenignLikely Benign0.117Likely Benign-0.78Neutral0.447Benign0.252Benign2.66Benign1.00Tolerated0.46920.5403112.6-16.00
c.3281C>A
S1094Y
2D
AIThe SynGAP1 missense variant S1094Y is not reported in ClinVar (status: none) but is present in gnomAD (ID 6‑33443833‑C‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (two benign, two pathogenic). Foldetta, a protein‑folding‑stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. High‑accuracy predictions therefore show a benign call from AlphaMissense‑Optimized, an inconclusive SGM Consensus, and no Foldetta data. Overall, the balance of evidence leans toward a pathogenic interpretation (five pathogenic versus four benign calls), and this does not contradict the ClinVar status, which currently has no assertion for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.938133Disordered0.981352Binding0.3580.8771.0006-33443833-C-A-5.609Likely Benign0.631Likely PathogenicLikely Benign0.155Likely Benign-2.07Neutral0.990Probably Damaging0.856Possibly Damaging2.45Pathogenic0.02Affected3.7750.10070.5877-2-3-0.576.10
c.3281C>G
S1094C
2D
AIThe SynGAP1 missense variant S1094C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. Two tools—AlphaMissense‑Default and ESM1b—return uncertain results. High‑accuracy assessments are limited: AlphaMissense‑Optimized indicates a benign effect; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields no clear consensus and is treated as unavailable; Foldetta data are not provided, so its stability prediction is also unavailable. Overall, the balance of evidence favors a pathogenic interpretation, and this conclusion does not conflict with the absence of a ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.938133Disordered0.981352Binding0.3580.8771.000-7.143In-Between0.425AmbiguousLikely Benign0.131Likely Benign-1.81Neutral0.997Probably Damaging0.946Probably Damaging2.45Pathogenic0.05Affected0.14030.63090-13.316.06
c.3281C>T
S1094F
2D
AIThe SynGAP1 missense variant S1094F is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized predicts a benign outcome, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—yields a tie and is therefore inconclusive. Foldetta, which would provide a protein‑folding stability estimate, has no available result for this variant. Overall, the majority of conventional predictors lean toward pathogenicity, but the single high‑accuracy tool predicts benign and the consensus is unresolved. Thus, the variant is most likely pathogenic based on the current predictions, and this assessment does not contradict any ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.938133Disordered0.981352Binding0.3580.8771.000-5.655Likely Benign0.666Likely PathogenicLikely Benign0.150Likely Benign-2.17Neutral0.990Probably Damaging0.856Possibly Damaging2.45Pathogenic0.02Affected0.09250.5851-3-23.660.10
c.3109A>C
I1037L
2D
AIThe SynGAP1 missense variant I1037L is not reported in ClinVar and is absent from gnomAD, indicating no known clinical or population evidence. Functional prediction tools uniformly favor a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity, and the only uncertain call comes from AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports the variant as “Likely Benign.” High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that I1037L is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-2.563Likely Benign0.448AmbiguousLikely Benign0.074Likely Benign-0.46Neutral0.421Benign0.128Benign2.82Benign0.81Tolerated0.09390.430222-0.70.00
c.3109A>G
I1037V
2D
AIThe SynGAP1 missense variant I1037V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that I1037V is most likely benign, and this conclusion is not contradicted by ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-2.326Likely Benign0.461AmbiguousLikely Benign0.085Likely Benign-0.09Neutral0.421Benign0.128Benign2.76Benign0.93Tolerated0.12290.398543-0.3-14.03
c.3109A>T
I1037F
2D
AIThe SynGAP1 missense variant I1037F is not reported in ClinVar and has no entries in gnomAD. Consensus from multiple in‑silico predictors shows a split: benign predictions come from REVEL, PROVEAN, SIFT, ESM1b, and FATHMM, while pathogenic predictions arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy tools further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, is not available for this variant. Overall, the majority of evidence points to a benign effect, and this assessment is consistent with the absence of a ClinVar pathogenic claim. Thus, the variant is most likely benign, and this conclusion does not contradict ClinVar, which has no pathogenic assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-3.517Likely Benign0.653Likely PathogenicLikely Benign0.115Likely Benign-0.97Neutral0.977Probably Damaging0.632Possibly Damaging2.71Benign0.16Tolerated0.06530.372210-1.734.02
c.3110T>A
I1037N
2D
AIThe SynGAP1 missense variant I1037N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a Likely Benign classification, while AlphaMissense‑Optimized remains uncertain. Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-3.955Likely Benign0.832Likely PathogenicAmbiguous0.131Likely Benign1.56Neutral0.666Possibly Damaging0.211Benign2.81Benign0.34Tolerated0.10220.1140-2-3-8.00.94
c.3110T>C
I1037T
2D
AIThe SynGAP1 missense variant I1037T is not reported in ClinVar (ClinVar ID None) but is present in gnomAD (ID 6‑33443662‑T‑C). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. Tools that predict a pathogenic effect are AlphaMissense‑Default and AlphaMissense‑Optimized. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as pathogenic, while the SGM‑Consensus remains Likely Benign; Foldetta results are unavailable. Overall, the majority of predictions (seven benign vs. two pathogenic) indicate that the variant is most likely benign, and this assessment does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.6256-33443662-T-C16.21e-7-2.565Likely Benign0.973Likely PathogenicLikely Pathogenic0.066Likely Benign0.40Neutral0.292Benign0.110Benign2.79Benign0.34Tolerated3.7750.10710.2175-10-5.2-12.05
c.3110T>G
I1037S
2D
AIThe SynGAP1 missense variant I1037S is not reported in ClinVar and has no entries in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), which classifies the variant as Likely Benign. Only AlphaMissense‑Default predicts a pathogenic outcome, while AlphaMissense‑Optimized is uncertain and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta) has no available result for this variant. Based on the overall consensus of the majority of tools, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-2.247Likely Benign0.935Likely PathogenicAmbiguous0.120Likely Benign0.43Neutral0.032Benign0.017Benign2.83Benign0.27Tolerated0.26340.1110-1-2-5.3-26.08
c.3111C>G
I1037M
2D
AIThe SynGAP1 missense variant I1037M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. Only two tools, polyPhen‑2 HumDiv and polyPhen‑2 HumVar, predict a pathogenic effect. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence supports a benign classification, and this is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-3.849Likely Benign0.333Likely BenignLikely Benign0.093Likely Benign-0.40Neutral0.977Probably Damaging0.721Possibly Damaging2.71Benign0.18Tolerated0.07750.388521-2.618.03
c.3205C>A
Q1069K
2D
AIThe SynGAP1 missense variant Q1069K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Overall, the majority of computational evidence points to a benign effect, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.981477Binding0.3330.9060.875-5.080Likely Benign0.542AmbiguousLikely Benign0.099Likely Benign-0.88Neutral0.625Possibly Damaging0.266Benign2.77Benign0.28Tolerated0.19040.507111-0.40.04
c.3205C>G
Q1069E
2D
AIThe SynGAP1 missense variant Q1069E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.981477Binding0.3330.9060.875-5.165Likely Benign0.322Likely BenignLikely Benign0.107Likely Benign-0.68Neutral0.451Benign0.266Benign2.76Benign0.33Tolerated0.14600.3127220.00.98
c.3206A>C
Q1069P
2D
AIThe SynGAP1 missense variant Q1069P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign consensus. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.981477Binding0.3330.9060.875-3.458Likely Benign0.056Likely BenignLikely Benign0.211Likely Benign0.75Neutral0.977Probably Damaging0.722Possibly Damaging2.73Benign1.00Tolerated0.21790.59440-11.9-31.01
c.3206A>G
Q1069R
2D
AIThe SynGAP1 missense variant Q1069R is not reported in ClinVar (ClinVar ID = None) and has no entries in gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable. Overall, the preponderance of evidence points to the variant being most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.981477Binding0.3330.9060.875-3.257Likely Benign0.467AmbiguousLikely Benign0.094Likely Benign-1.17Neutral0.666Possibly Damaging0.355Benign2.73Benign0.21Tolerated0.15570.311411-1.028.06
c.3206A>T
Q1069L
2D
AIThe SynGAP1 missense variant Q1069L is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.981477Binding0.3330.9060.875-4.278Likely Benign0.141Likely BenignLikely Benign0.104Likely Benign-0.96Neutral0.003Benign0.008Benign2.83Benign0.10Tolerated0.09360.6624-2-27.3-14.97
c.3207G>C
Q1069H
2D
AIThe SynGAP1 missense variant Q1069H is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.981477Binding0.3330.9060.875-4.723Likely Benign0.306Likely BenignLikely Benign0.085Likely Benign-1.31Neutral0.006Benign0.008Benign2.69Benign0.06Tolerated0.15600.4678300.39.01
c.3207G>T
Q1069H
2D
AIThe SynGAP1 missense variant Q1069H is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.981477Binding0.3330.9060.875-4.723Likely Benign0.306Likely BenignLikely Benign0.085Likely Benign-1.31Neutral0.006Benign0.008Benign2.69Benign0.06Tolerated0.15600.4678300.39.01
c.3988C>A
Q1330K
2D
AIThe SynGAP1 missense variant Q1330K is catalogued in gnomAD (ID 6‑33451862‑C‑A) but has no ClinVar entry. Functional prediction tools split in two groups: benign calls come from REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized; pathogenic calls come from polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” status, reflecting the majority of benign predictions. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence—including the high‑accuracy tools—suggests that Q1330K is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.931969Binding0.3690.7520.8756-33451862-C-A-4.120Likely Benign0.605Likely PathogenicLikely Benign0.027Likely Benign-1.52Neutral0.544Possibly Damaging0.259Benign3.98Benign0.04Affected3.7750.16070.412711-0.40.04
c.3988C>G
Q1330E
2D
AIThe SynGAP1 missense variant Q1330E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as likely benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign and the SGM‑Consensus also reports likely benign; Foldetta results are unavailable. Overall, the consensus of the available predictions points to a benign impact, and this is consistent with the lack of ClinVar evidence, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.931969Binding0.3690.7520.875-3.428Likely Benign0.281Likely BenignLikely Benign0.035Likely Benign-1.12Neutral0.613Possibly Damaging0.240Benign3.98Benign0.06Tolerated0.13460.2409220.00.98
c.3989A>C
Q1330P
2D
AIThe SynGAP1 missense variant Q1330P is listed in gnomAD (ID 6‑33451863‑A‑C) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, and FATHMM; pathogenic predictions come from polyPhen‑2 HumDiv, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments are mixed: AlphaMissense‑Optimized yields an “Uncertain” result, SGM‑Consensus confirms a benign leaning, and Foldetta (combining FoldX‑MD and Rosetta outputs) is not available for this variant. Overall, the balance of evidence favors a benign effect, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.931969Binding0.3690.7520.8756-33451863-A-C-3.087Likely Benign0.814Likely PathogenicAmbiguous0.076Likely Benign-2.45Neutral0.898Possibly Damaging0.441Benign3.91Benign0.03Affected3.7750.22660.4983-101.9-31.01
c.3989A>G
Q1330R
2D
AIThe SynGAP1 missense variant Q1330R is listed in gnomAD (ID 6‑33451863‑A‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.931969Binding0.3690.7520.8756-33451863-A-G-3.601Likely Benign0.472AmbiguousLikely Benign0.031Likely Benign-1.65Neutral0.898Possibly Damaging0.341Benign3.95Benign0.03Affected3.7750.13490.233311-1.028.06
c.3989A>T
Q1330L
2D
AIThe SynGAP1 missense variant Q1330L is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and SIFT. AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction. Foldetta results are unavailable. Overall, the majority of evidence (5 benign vs 3 pathogenic) supports a benign classification. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.943310Disordered0.931969Binding0.3690.7520.875-3.780Likely Benign0.417AmbiguousLikely Benign0.110Likely Benign-2.74Deleterious0.784Possibly Damaging0.341Benign3.92Benign0.02Affected0.07410.5480-2-27.3-14.97
c.3990G>C
Q1330H
2D
AIThe SynGAP1 missense variant Q1330H is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools cluster into two consensus groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign effect. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, the SGM‑Consensus also reports it as likely benign, and Foldetta (which integrates FoldX‑MD and Rosetta stability calculations) has no available result for this residue. Based on the preponderance of benign predictions from multiple independent algorithms and the lack of pathogenic evidence, the variant is most likely benign. This conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.931969Binding0.3690.7520.875-3.557Likely Benign0.477AmbiguousLikely Benign0.066Likely Benign-1.91Neutral0.969Probably Damaging0.732Possibly Damaging3.91Benign0.02Affected0.11900.3996300.39.01
c.3990G>T
Q1330H
2D
AIThe SynGAP1 missense variant Q1330H is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools cluster into two consensus groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign effect. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, the SGM‑Consensus also reports it as likely benign, and Foldetta (which integrates FoldX‑MD and Rosetta stability calculations) has no available result for this residue. Based on the preponderance of benign predictions from multiple independent algorithms and the lack of pathogenic evidence, the variant is most likely benign. This conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.931969Binding0.3690.7520.875-3.557Likely Benign0.477AmbiguousLikely Benign0.066Likely Benign-1.91Neutral0.969Probably Damaging0.732Possibly Damaging3.91Benign0.02Affected0.11900.3996300.39.01
c.3103C>A
P1035T
2D
AIThe SynGAP1 missense variant P1035T is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default remains uncertain, and no Foldetta stability assessment is available. High‑accuracy evidence from AlphaMissense‑Optimized and the SGM‑Consensus both support a benign classification, while the absence of a Foldetta result does not alter this view. Overall, the majority of predictions indicate a benign effect, and this is consistent with the ClinVar “Uncertain” designation rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.945666Disordered0.989572Binding0.3000.7560.625Uncertain 1-4.447Likely Benign0.426AmbiguousLikely Benign0.087Likely Benign-0.96Neutral0.901Possibly Damaging0.537Possibly Damaging2.72Benign0.23Tolerated3.7750.16280.72200-10.93.99
c.3103C>G
P1035A
2D
AIThe SynGAP1 missense variant P1035A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic outcome, creating a single discordant signal. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.945666Disordered0.989572Binding0.3000.7560.625-4.293Likely Benign0.241Likely BenignLikely Benign0.041Likely Benign-1.02Neutral0.481Possibly Damaging0.222Benign2.74Benign0.41Tolerated0.31880.60221-13.4-26.04
c.3103C>T
P1035S
2D
AIThe SynGAP1 missense variant P1035S is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign. Only polyPhen‑2 HumDiv flags it as pathogenic, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign outcome. High‑accuracy assessments further support this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus itself is benign; Foldetta results are unavailable. Taken together, the preponderance of evidence points to a benign impact for P1035S, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.945666Disordered0.989572Binding0.3000.7560.625-3.678Likely Benign0.341AmbiguousLikely Benign0.059Likely Benign-0.97Neutral0.818Possibly Damaging0.355Benign2.79Benign0.28Tolerated0.32570.62531-10.8-10.04
c.3104C>A
P1035H
2D
AIThe SynGAP1 missense variant P1035H is not reported in ClinVar and has no entries in gnomAD. Consensus predictions from multiple in‑silico tools are mixed: benign calls come from SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, whereas pathogenic calls are made by polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized predicts a benign effect, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates a likely benign outcome. No Foldetta stability analysis is available for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.945666Disordered0.989572Binding0.3000.7560.625-5.333Likely Benign0.608Likely PathogenicLikely Benign0.058Likely Benign-0.76Neutral0.997Probably Damaging0.889Possibly Damaging2.68Benign0.15Tolerated0.18930.56690-2-1.640.02
c.3104C>G
P1035R
2D
AIThe SynGAP1 missense variant P1035R is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and there is no ClinVar entry to contradict this assessment. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.945666Disordered0.989572Binding0.3000.7560.625-4.534Likely Benign0.604Likely PathogenicLikely Benign0.119Likely Benign1.07Neutral0.970Probably Damaging0.728Possibly Damaging2.89Benign0.93Tolerated0.14240.42010-2-2.959.07
c.3104C>T
P1035L
2D
AIThe SynGAP1 missense variant P1035L is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.945666Disordered0.989572Binding0.3000.7560.625-5.694Likely Benign0.675Likely PathogenicLikely Benign0.071Likely Benign-2.11Neutral0.970Probably Damaging0.728Possibly Damaging2.70Benign0.21Tolerated0.24440.7354-3-35.416.04
c.3307C>A
R1103S
2D
AIThe SynGAP1 missense variant R1103S is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and FATHMM, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign, and Foldetta results are unavailable. Overall, the majority of evidence (six benign versus two pathogenic predictions) indicates that R1103S is most likely benign, and this conclusion does not contradict any ClinVar annotation because no ClinVar claim exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.945666Disordered0.957363Binding0.3280.8620.875-3.611Likely Benign0.464AmbiguousLikely Benign0.111Likely Benign-1.94Neutral0.511Possibly Damaging0.187Benign2.48Pathogenic0.28Tolerated0.30250.42240-13.7-69.11
c.3307C>G
R1103G
2D
AIThe SynGAP1 missense variant R1103G is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 benign vs 2 pathogenic), and Foldetta results are unavailable. Overall, the balance of evidence—five benign predictions versus four pathogenic, with a benign high‑accuracy tool and no conflicting ClinVar annotation—suggests that the variant is most likely benign. This conclusion does not contradict any ClinVar status, as the variant has not been reported there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.945666Disordered0.957363Binding0.3280.8620.875-3.516Likely Benign0.221Likely BenignLikely Benign0.132Likely Benign-2.65Deleterious0.911Possibly Damaging0.308Benign2.44Pathogenic0.03Affected0.34290.4077-3-24.1-99.14
c.3307C>T
R1103C
2D
AISynGAP1 missense variant R1103C is listed in ClinVar with an uncertain significance and is present in gnomAD (ID 6‑33443859‑C‑T). Prediction tools that agree on a benign effect include REVEL, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (two benign, two pathogenic). AlphaMissense‑Optimized reports a benign outcome, while Foldetta results are unavailable. Overall, the balance of evidence favors a pathogenic interpretation, which is in contrast to the ClinVar designation of uncertain significance.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.945666Disordered0.957363Binding0.3280.8620.875Uncertain 16-33443859-C-T63.92e-6-2.440Likely Benign0.246Likely BenignLikely Benign0.140Likely Benign-3.01Deleterious0.996Probably Damaging0.787Possibly Damaging2.41Pathogenic0.01Affected3.7750.33760.4121-3-47.0-53.05
c.3308G>A
R1103H
2D
AIThe SynGAP1 missense variant R1103H is listed in ClinVar (ID 577408.0) as benign and is present in gnomAD (variant ID 6‑33443860‑G‑A). Prediction tools that classify the variant as benign include REVEL, PROVEAN, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM Consensus. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as benign, while Foldetta results are unavailable. Overall, the majority of predictions support a benign impact, and this conclusion aligns with the ClinVar benign classification, indicating no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.945666Disordered0.957363Binding0.3280.8620.875Benign/Likely benign 36-33443860-G-A312.03e-5-3.622Likely Benign0.156Likely BenignLikely Benign0.116Likely Benign-1.97Neutral0.996Probably Damaging0.733Possibly Damaging2.49Pathogenic0.01Affected3.7750.29770.2380201.3-19.05
c.3308G>C
R1103P
2D
AIThe SynGAP1 missense variant R1103P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are not available. Overall, the majority of predictions (six benign vs. four pathogenic) support a benign classification. There is no ClinVar entry to contradict this assessment, so the variant is most likely benign based on current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.945666Disordered0.957363Binding0.3280.8620.875-2.149Likely Benign0.229Likely BenignLikely Benign0.098Likely Benign-2.48Neutral0.969Probably Damaging0.659Possibly Damaging2.43Pathogenic0.02Affected0.22880.51090-22.9-59.07
c.3308G>T
R1103L
2D
AIThe SynGAP1 missense variant R1103L is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443860‑G‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” outcome (3 benign vs. 1 pathogenic votes). High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this is consistent with the ClinVar “Uncertain” classification rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.945666Disordered0.957363Binding0.3280.8620.875Uncertain 16-33443860-G-T-2.330Likely Benign0.205Likely BenignLikely Benign0.173Likely Benign-2.35Neutral0.002Benign0.005Benign2.44Pathogenic0.02Affected3.7750.20980.5181-3-28.3-43.03
c.3202T>A
L1068M
2D
AIThe SynGAP1 missense variant L1068M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of predictions (six benign vs. four pathogenic) lean toward a benign impact. There is no ClinVar entry to contradict this assessment, so the variant is most likely benign based on current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.947281Disordered0.981041Binding0.3620.9070.875-5.739Likely Benign0.120Likely BenignLikely Benign0.043Likely Benign-0.22Neutral0.977Probably Damaging0.721Possibly Damaging2.49Pathogenic0.00Affected0.09300.458242-1.918.03
c.3202T>G
L1068V
2D
AIThe SynGAP1 missense variant L1068V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.947281Disordered0.981041Binding0.3620.9070.875-5.325Likely Benign0.078Likely BenignLikely Benign0.051Likely Benign-0.58Neutral0.451Benign0.110Benign2.54Benign0.00Affected0.16190.4404210.4-14.03
c.3203T>C
L1068S
2D
AIThe SynGAP1 missense variant L1068S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.947281Disordered0.981041Binding0.3620.9070.875-6.297Likely Benign0.211Likely BenignLikely Benign0.175Likely Benign-0.57Neutral0.032Benign0.017Benign2.59Benign0.00Affected0.28100.1853-3-2-4.6-26.08
c.3203T>G
L1068W
2D
AIThe SynGAP1 missense variant L1068W is not reported in ClinVar (ClinVar status: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, and AlphaMissense‑Optimized, whereas polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all predict a pathogenic outcome; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further refine the picture: AlphaMissense‑Optimized remains benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) resolves as pathogenic, and Foldetta’s protein‑folding stability analysis is unavailable. Overall, the majority of evidence points toward a pathogenic impact for L1068W. This conclusion is not contradicted by ClinVar, which contains no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.947281Disordered0.981041Binding0.3620.9070.875-8.574Likely Pathogenic0.342AmbiguousLikely Benign0.151Likely Benign-1.96Neutral0.994Probably Damaging0.884Possibly Damaging2.46Pathogenic0.00Affected0.07420.3763-2-2-4.773.05
c.3204G>C
L1068F
2D
AIThe SynGAP1 missense variant L1068F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of predictions (six benign vs. four pathogenic) favor a benign classification. Thus, the variant is most likely benign based on current computational evidence, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.947281Disordered0.981041Binding0.3620.9070.875-6.338Likely Benign0.182Likely BenignLikely Benign0.107Likely Benign-1.38Neutral0.934Possibly Damaging0.537Possibly Damaging2.49Pathogenic0.00Affected0.07540.420220-1.034.02
c.3204G>T
L1068F
2D
AIThe SynGAP1 missense variant L1068F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of predictions (six benign vs. four pathogenic) favor a benign classification. Thus, the variant is most likely benign based on current computational evidence, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.947281Disordered0.981041Binding0.3620.9070.875-6.338Likely Benign0.182Likely BenignLikely Benign0.106Likely Benign-1.38Neutral0.934Possibly Damaging0.537Possibly Damaging2.49Pathogenic0.00Affected0.07540.420220-1.034.02
c.3106C>A
Q1036K
2D
AIThe SynGAP1 missense variant Q1036K is not reported in ClinVar and has no entry in gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus, REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. High‑accuracy assessments reinforce the benign prediction: AlphaMissense‑Optimized scores the variant as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. No Foldetta stability analysis is available for this variant. Overall, the majority of computational evidence indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.987955Binding0.2750.7650.625-3.757Likely Benign0.646Likely PathogenicLikely Benign0.079Likely Benign-1.72Neutral0.011Benign0.005Benign2.58Benign0.05Affected0.20960.522011-0.40.04
c.3106C>G
Q1036E
2D
AIThe SynGAP1 missense variant Q1036E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign. Only SIFT predicts a pathogenic outcome. When predictions are grouped by consensus, the benign group contains nine tools, while the pathogenic group contains one (SIFT). High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable, so they do not influence the assessment. Overall, the evidence strongly suggests the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.987955Binding0.2750.7650.625-3.797Likely Benign0.313Likely BenignLikely Benign0.056Likely Benign-1.22Neutral0.264Benign0.062Benign2.59Benign0.03Affected0.16290.3484220.00.98
c.3107A>C
Q1036P
2D
AIThe SynGAP1 missense variant Q1036P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as tolerated or benign. In contrast, polyPhen‑2 HumDiv and SIFT predict a damaging or pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign status. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence from multiple prediction algorithms and the consensus score indicates that the variant is most likely benign, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.987955Binding0.2750.7650.625-2.491Likely Benign0.135Likely BenignLikely Benign0.104Likely Benign-2.00Neutral0.802Possibly Damaging0.238Benign2.57Benign0.01Affected0.20180.55640-11.9-31.01
c.3107A>G
Q1036R
2D
AIThe SynGAP1 missense variant Q1036R is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions come from SIFT and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority of the four high‑accuracy tools) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the collective evidence points to a benign effect for Q1036R, and this conclusion does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.987955Binding0.2750.7650.625-3.816Likely Benign0.596Likely PathogenicLikely Benign0.083Likely Benign-1.32Neutral0.292Benign0.071Benign2.54Benign0.04Affected0.17100.307111-1.028.06
c.3107A>T
Q1036L
2D
AIThe SynGAP1 missense variant Q1036L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors a benign outcome, with two benign votes versus one pathogenic and one uncertain. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.948786Disordered0.987955Binding0.2750.7650.625-4.389Likely Benign0.435AmbiguousLikely Benign0.092Likely Benign-2.92Deleterious0.152Benign0.045Benign2.52Benign0.01Affected0.10690.5996-2-27.3-14.97
c.3108G>C
Q1036H
2D
AIThe SynGAP1 missense variant Q1036H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.987955Binding0.2750.7650.625-4.189Likely Benign0.536AmbiguousLikely Benign0.065Likely Benign-1.18Neutral0.977Probably Damaging0.615Possibly Damaging2.50Benign0.29Tolerated3.7750.16410.4835030.39.01
c.3108G>T
Q1036H
2D
AIThe SynGAP1 missense variant Q1036H is listed in gnomAD (ID 6‑33443660‑G‑T) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and Foldetta (FoldX‑MD/Rosetta stability assessment) has no available result. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta data are missing. Overall, the majority of reliable predictors indicate a benign impact, and this is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.987955Binding0.2750.7650.6256-33443660-G-T16.20e-7-4.189Likely Benign0.536AmbiguousLikely Benign0.065Likely Benign-1.18Neutral0.977Probably Damaging0.615Possibly Damaging2.50Benign0.29Tolerated3.7750.16410.4835030.39.01
c.3976C>A
P1326T
2D
AIThe SynGAP1 missense variant P1326T is reported in gnomAD (ID 6‑33451850‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports a benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT predict a pathogenic impact. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority of the same four high‑accuracy tools) is benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates that P1326T is most likely benign, and this assessment does not contradict any ClinVar classification because no ClinVar variant is listed.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.887377Binding0.3930.7820.8756-33451850-C-A-5.755Likely Benign0.117Likely BenignLikely Benign0.135Likely Benign-0.26Neutral0.999Probably Damaging0.992Probably Damaging3.71Benign0.00Affected3.7750.19550.5517-100.93.99
c.3976C>G
P1326A
2D
AIThe SynGAP1 missense variant P1326A is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.887377Binding0.3930.7820.875-4.450Likely Benign0.068Likely BenignLikely Benign0.097Likely Benign-0.76Neutral0.996Probably Damaging0.986Probably Damaging3.73Benign0.00Affected0.37280.43331-13.4-26.04
c.3976C>T
P1326S
2D
AIThe SynGAP1 missense variant P1326S is listed in ClinVar with no submitted interpretation and is present in gnomAD (ID 6‑33451850‑C‑T). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT predict a pathogenic impact. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence—including the high‑accuracy tools—supports a benign classification. This conclusion does not contradict the ClinVar status, which currently has no pathogenic assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.887377Binding0.3930.7820.8756-33451850-C-T-5.221Likely Benign0.121Likely BenignLikely Benign0.107Likely Benign-0.35Neutral0.999Probably Damaging0.992Probably Damaging3.74Benign0.00Affected3.7750.37220.4563-110.8-10.04
c.3977C>A
P1326Q
2D
AIThe SynGAP1 missense variant P1326Q is listed in ClinVar (ID 2806103.0) with an “Uncertain” status and is present in gnomAD (variant ID 6‑33451851‑C‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict the ClinVar “Uncertain” classification, which remains inconclusive.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.887377Binding0.3930.7820.875Uncertain 16-33451851-C-A16.40e-7-5.422Likely Benign0.128Likely BenignLikely Benign0.138Likely Benign-0.86Neutral0.999Probably Damaging0.994Probably Damaging3.62Benign0.00Affected3.7750.17690.4457-10-1.931.01
c.3977C>G
P1326R
2D
AIThe SynGAP1 missense variant P1326R is listed in ClinVar (ID 2429486.0) with an “Uncertain” status and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote) also benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.887377Binding0.3930.7820.875Uncertain 1-5.097Likely Benign0.240Likely BenignLikely Benign0.133Likely Benign-0.82Neutral0.999Probably Damaging0.994Probably Damaging3.62Benign0.00Affected3.7750.17100.28080-2-2.959.07
c.3977C>T
P1326L
2D
AIThe SynGAP1 missense variant P1326L is listed in ClinVar (ID 1004879.0) with an “Uncertain” clinical significance and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT predict a pathogenic impact. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as “Likely Benign,” and AlphaMissense‑Optimized also predicts benign. No Foldetta (FoldX‑MD/ Rosetta) stability result is available for this variant. Overall, the majority of evidence—including the high‑confidence SGM consensus and AlphaMissense‑Optimized prediction—supports a benign classification, which does not contradict the current ClinVar status of uncertainty.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.948786Disordered0.887377Binding0.3930.7820.875Uncertain 1-5.541Likely Benign0.115Likely BenignLikely Benign0.117Likely Benign-1.06Neutral0.999Probably Damaging0.994Probably Damaging3.62Benign0.00Affected3.7750.27230.6113-3-35.416.04
c.2905G>A
G969R
2D
AIThe SynGAP1 missense variant G969R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.956572Binding0.4050.8980.750-4.783Likely Benign0.316Likely BenignLikely Benign0.152Likely Benign-0.70Neutral0.611Possibly Damaging0.305Benign4.20Benign0.01Affected0.10390.5473-3-2-4.199.14
c.2905G>C
G969R
2D
AIThe SynGAP1 missense variant G969R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.956572Binding0.4050.8980.750-4.783Likely Benign0.316Likely BenignLikely Benign0.152Likely Benign-0.70Neutral0.611Possibly Damaging0.305Benign4.20Benign0.01Affected0.10390.5473-3-2-4.199.14
c.2906G>A
G969E
2D
AIThe SynGAP1 missense variant G969E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.956572Binding0.4050.8980.750-4.721Likely Benign0.167Likely BenignLikely Benign0.118Likely Benign-0.10Neutral0.611Possibly Damaging0.171Benign4.28Benign0.01Affected0.16630.53990-2-3.172.06
c.2906G>C
G969A
2D
AIThe SynGAP1 missense variant G969A is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity, so the pathogenic‑prediction group is empty. High‑accuracy assessments corroborate this benign consensus: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are not available, so they do not influence the interpretation. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.956572Binding0.4050.8980.750-4.693Likely Benign0.076Likely BenignLikely Benign0.120Likely Benign-0.36Neutral0.393Benign0.096Benign4.25Benign0.51Tolerated0.34140.5096102.214.03
c.2906G>T
G969V
2D
AIThe SynGAP1 missense variant G969V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.956572Binding0.4050.8980.750-5.946Likely Benign0.089Likely BenignLikely Benign0.116Likely Benign-0.92Neutral0.761Possibly Damaging0.239Benign4.18Benign0.01Affected0.14970.3847-1-34.642.08
c.2911C>A
P971T
2D
AIThe SynGAP1 missense variant P971T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.951523Binding0.5450.9050.625-5.627Likely Benign0.053Likely BenignLikely Benign0.053Likely Benign-0.95Neutral0.001Benign0.003Benign3.96Benign0.00Affected0.13880.58880-10.93.99
c.2911C>G
P971A
2D
AIThe SynGAP1 missense variant P971A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.951523Binding0.5450.9050.625-4.244Likely Benign0.049Likely BenignLikely Benign0.060Likely Benign-0.51Neutral0.000Benign0.002Benign4.05Benign0.00Affected0.31000.52821-13.4-26.04
c.2911C>T
P971S
2D
AIThe SynGAP1 missense variant P971S is catalogued in gnomAD (ID 6‑33443463‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) all indicate a benign or likely benign outcome. Only SIFT classifies the change as pathogenic, representing a minority opinion. High‑accuracy assessments further support benignity: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise reports likely benign. No Foldetta stability analysis is available, so it does not influence the overall assessment. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.951523Binding0.5450.9050.6256-33443463-C-T16.20e-7-4.188Likely Benign0.061Likely BenignLikely Benign0.058Likely Benign-0.51Neutral0.002Benign0.003Benign3.99Benign0.00Affected4.3220.30090.5667-110.8-10.04
c.2912C>A
P971H
2D
AIThe SynGAP1 missense variant P971H is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443464‑C‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; a Foldetta stability prediction is not available. Overall, the majority of evidence points to a benign impact, which does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.951523Binding0.5450.9050.625Uncertain 16-33443464-C-A16.20e-7-5.243Likely Benign0.086Likely BenignLikely Benign0.039Likely Benign-1.11Neutral0.898Possibly Damaging0.477Possibly Damaging3.89Benign0.00Affected4.3220.15840.4858-20-1.640.02
c.2912C>G
P971R
2D
AIThe SynGAP1 missense variant P971R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.951523Binding0.5450.9050.625-4.407Likely Benign0.149Likely BenignLikely Benign0.042Likely Benign-1.01Neutral0.453Possibly Damaging0.078Benign3.91Benign0.00Affected0.13060.38180-2-2.959.07
c.2912C>T
P971L
2D
AIThe SynGAP1 missense variant P971L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.951523Binding0.5450.9050.625-4.892Likely Benign0.070Likely BenignLikely Benign0.030Likely Benign-1.57Neutral0.144Benign0.026Benign3.93Benign0.00Affected0.20460.5985-3-35.416.04
c.3430T>A
L1144M
2D
AIThe SynGAP1 missense variant L1144M is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: **benign** – REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized; **pathogenic** – polyPhen‑2 (HumDiv and HumVar) and SIFT. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports Likely Benign. Foldetta predictions are unavailable. Overall, the majority of evidence points to a benign effect for L1144M, and this conclusion does not conflict with ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.726803Binding0.2770.8401.000-4.787Likely Benign0.199Likely BenignLikely Benign0.277Likely Benign-0.25Neutral0.999Probably Damaging0.979Probably Damaging5.38Benign0.05Affected0.08460.386342-1.918.03
c.3430T>G
L1144V
2D
AIThe SynGAP1 missense variant L1144V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools, polyPhen‑2 HumDiv and HumVar, predict pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy methods reinforce this view: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.726803Binding0.2770.8401.000-4.025Likely Benign0.151Likely BenignLikely Benign0.227Likely Benign-0.04Neutral0.952Possibly Damaging0.770Possibly Damaging5.43Benign0.70Tolerated0.15530.3297210.4-14.03
c.3431T>C
L1144S
2D
AIThe SynGAP1 missense variant L1144S has no ClinVar entry and is not reported in gnomAD. Functional prediction tools show a split: benign calls come from PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic calls come from REVEL, polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default. Grouping by consensus, the majority of tools (four benign vs. five pathogenic) lean slightly toward pathogenicity, but the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—labels the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability predictor, did not return a result for this variant. Overall, the computational evidence most strongly suggests the variant is benign, and this conclusion does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.726803Binding0.2770.8401.000-2.248Likely Benign0.683Likely PathogenicLikely Benign0.580Likely Pathogenic-1.69Neutral1.000Probably Damaging0.979Probably Damaging5.41Benign0.01Affected0.30450.0863-3-2-4.6-26.08
c.3431T>G
L1144W
2D
AIThe SynGAP1 missense variant L1144W is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33444466‑T‑G). Prediction tools that agree on a benign effect include ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a 2‑to‑2 split; Foldetta results are unavailable. Overall, the majority of predictions (six pathogenic vs. three benign) indicate a pathogenic impact. This conclusion is not contradicted by ClinVar status, which has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.950334Disordered0.726803Binding0.2770.8401.0006-33444466-T-G16.20e-7-5.745Likely Benign0.707Likely PathogenicLikely Benign0.575Likely Pathogenic-2.87Deleterious1.000Probably Damaging0.995Probably Damaging5.36Benign0.01Affected4.3240.07030.3166-2-2-4.773.05
c.3432G>C
L1144F
2D
AIThe SynGAP1 missense variant L1144F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for the variant, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.726803Binding0.2770.8401.000-4.375Likely Benign0.406AmbiguousLikely Benign0.415Likely Benign-1.71Neutral0.999Probably Damaging0.969Probably Damaging5.69Benign0.04Affected0.06850.328320-1.034.02
c.3432G>T
L1144F
2D
AIThe SynGAP1 missense variant L1144F is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions come from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the aggregate evidence, the variant is most likely benign. This assessment does not contradict ClinVar status, as no ClinVar claim exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.726803Binding0.2770.8401.000-4.375Likely Benign0.406AmbiguousLikely Benign0.415Likely Benign-1.71Neutral0.999Probably Damaging0.969Probably Damaging5.69Benign0.04Affected0.06850.328320-1.034.02
c.2908G>A
E970K
2D
AIThe SynGAP1 missense variant E970K is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign interpretation, and this conclusion does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.951925Disordered0.953422Binding0.3420.9020.750-3.344Likely Benign0.303Likely BenignLikely Benign0.102Likely Benign-0.24Neutral0.078Benign0.042Benign4.18Benign0.17Tolerated0.33720.736101-0.4-0.94
c.2908G>C
E970Q
2D
AIThe SynGAP1 missense variant E970Q is catalogued in gnomAD (6-33443460‑G‑C) and has no ClinVar entry. All available in silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool reports a pathogenic outcome. Grouping by consensus, the benign‑predicting tools comprise the entire set, while no pathogenic predictions are present. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are unavailable. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.951925Disordered0.953422Binding0.3420.9020.7506-33443460-G-C16.20e-7-2.662Likely Benign0.141Likely BenignLikely Benign0.053Likely Benign-0.23Neutral0.007Benign0.006Benign4.13Benign0.21Tolerated4.3220.25770.6899220.0-0.98
c.2909A>C
E970A
2D
AIThe SynGAP1 missense variant E970A is not reported in ClinVar and is absent from gnomAD. All available in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the consensus of all predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.951925Disordered0.953422Binding0.3420.9020.750-1.704Likely Benign0.156Likely BenignLikely Benign0.068Likely Benign-0.89Neutral0.069Benign0.018Benign4.15Benign0.19Tolerated0.36790.67980-15.3-58.04
c.2909A>G
E970G
2D
AIThe SynGAP1 missense variant E970G is listed in ClinVar (ID 2013677.0) as Benign and is not reported in gnomAD. All available in‑silico predictors classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts a benign effect, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no reported result for this variant. Overall, the computational evidence overwhelmingly supports a benign classification, which is consistent with the ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.951925Disordered0.953422Binding0.3420.9020.750Benign 1-0.167Likely Benign0.139Likely BenignLikely Benign0.139Likely Benign-0.93Neutral0.144Benign0.058Benign4.09Benign0.10Tolerated4.3220.27010.58330-23.1-72.06
c.2909A>T
E970V
2D
AIThe SynGAP1 missense variant E970V is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign interpretation, and this conclusion does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.951925Disordered0.953422Binding0.3420.9020.750-2.791Likely Benign0.208Likely BenignLikely Benign0.245Likely Benign-1.08Neutral0.002Benign0.002Benign4.11Benign0.08Tolerated0.19900.7037-2-27.7-29.98
c.2910G>C
E970D
2D
AIThe SynGAP1 missense variant E970D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification—there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.951925Disordered0.953422Binding0.3420.9020.750-3.381Likely Benign0.062Likely BenignLikely Benign0.063Likely Benign-0.44Neutral0.001Benign0.001Benign4.14Benign0.33Tolerated0.27290.4610320.0-14.03
c.2910G>T
E970D
2D
AIThe SynGAP1 missense variant E970D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.951925Disordered0.953422Binding0.3420.9020.750-3.381Likely Benign0.062Likely BenignLikely Benign0.063Likely Benign-0.44Neutral0.001Benign0.001Benign4.14Benign0.33Tolerated0.27290.4610320.0-14.03
c.2362T>A
S788T
2D
AIThe SynGAP1 missense variant S788T is listed in ClinVar with an uncertain significance (ClinVar ID 392728.0) and is present in the gnomAD database (gnomAD ID 6‑33442914‑T‑A). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score, which is derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN. Tools that predict a pathogenic outcome are polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, while the SGM‑Consensus (majority vote) also favors a benign interpretation. No Foldetta stability prediction is available for this variant. Overall, the majority of computational evidence points to a benign effect, which is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.956248Disordered0.573557Binding0.3490.8950.750Uncertain 26-33442914-T-A42.49e-6-4.288Likely Benign0.288Likely BenignLikely Benign0.092Likely Benign-2.25Neutral0.979Probably Damaging0.982Probably Damaging1.55Pathogenic0.02Affected3.6460.17940.6339110.114.03
c.2362T>C
S788P
2D
AIThe SynGAP1 missense variant S788P is catalogued in gnomAD (ID 6‑33442914‑T‑C) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, ESM1b, and AlphaMissense‑Optimized, whereas pathogenic predictions are reported by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. The AlphaMissense‑Default score is uncertain. A consensus derived from the SGM framework (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a pathogenic verdict. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus as pathogenic, and Foldetta (combining FoldX‑MD and Rosetta) is unavailable for this residue. Taken together, the preponderance of evidence from standard predictors and the SGM consensus points to a likely pathogenic effect, which does not contradict any existing ClinVar annotation because none is present.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.956248Disordered0.573557Binding0.3490.8950.7506-33442914-T-C-1.857Likely Benign0.435AmbiguousLikely Benign0.236Likely Benign-3.91Deleterious0.997Probably Damaging0.995Probably Damaging1.51Pathogenic0.01Affected3.6460.23380.5537-11-0.810.04
c.2362T>G
S788A
2D
AIThe SynGAP1 missense variant S788A is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for S788A. This consensus does not contradict ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.956248Disordered0.573557Binding0.3490.8950.750-5.381Likely Benign0.255Likely BenignLikely Benign0.088Likely Benign-2.24Neutral0.979Probably Damaging0.982Probably Damaging1.59Pathogenic0.02Affected0.50790.5041Strenghten112.6-16.00
c.2363C>A
S788Y
2D
AIThe SynGAP1 missense variant S788Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Prediction tools that agree on a benign effect include only REVEL, whereas the remaining tools—PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and the SGM‑Consensus score—consistently predict a pathogenic or likely pathogenic impact. High‑accuracy assessments show that the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely pathogenic effect, AlphaMissense‑Optimized is uncertain (treated as unavailable), and Foldetta results are not provided. Based on the collective predictions, the variant is most likely pathogenic, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicSH3-binding motif0.956248Disordered0.573557Binding0.3490.8950.750-8.745Likely Pathogenic0.795Likely PathogenicAmbiguous0.251Likely Benign-4.56Deleterious0.997Probably Damaging0.996Probably Damaging1.50Pathogenic0.00Affected0.08440.5551-3-2-0.576.10
c.2363C>G
S788C
2D
AIThe SynGAP1 missense variant S788C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect are REVEL and AlphaMissense‑Optimized, while five tools (PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM) predict a pathogenic outcome. Two tools (ESM1b and AlphaMissense‑Default) return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, whereas the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—classifies the variant as pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a pathogenic effect, and this conclusion does not contradict any ClinVar status because the variant has not yet been classified in that database.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.956248Disordered0.573557Binding0.3490.8950.750-7.935In-Between0.472AmbiguousLikely Benign0.269Likely Benign-3.90Deleterious0.999Probably Damaging0.997Probably Damaging1.50Pathogenic0.00Affected0.13930.60730-13.316.06
c.2363C>T
S788F
2D
AIThe SynGAP1 missense variant S788F is not reported in ClinVar and has no entry in gnomAD. Prediction tools that agree on a benign effect include REVEL and AlphaMissense‑Optimized, whereas the majority of tools predict a pathogenic impact: PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and the SGM‑Consensus score (Likely Pathogenic). ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM‑Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates likely pathogenic; Foldetta stability analysis is unavailable. Overall, the preponderance of predictions points to a pathogenic effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicSH3-binding motif0.956248Disordered0.573557Binding0.3490.8950.750-7.870In-Between0.749Likely PathogenicLikely Benign0.275Likely Benign-4.73Deleterious0.997Probably Damaging0.996Probably Damaging1.50Pathogenic0.00Affected0.07810.5824-3-23.660.10
c.3121C>A
P1041T
2D
AIThe SynGAP1 missense variant P1041T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is benign, and this conclusion does not contradict any ClinVar annotation (none present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.962114Disordered0.967463Binding0.3450.8330.625-5.009Likely Benign0.187Likely BenignLikely Benign0.361Likely Benign-2.45Neutral0.051Benign0.025Benign5.50Benign0.10Tolerated0.16320.66990-10.93.99
c.3121C>G
P1041A
2D
AIThe SynGAP1 missense variant P1041A is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and polyPhen‑2 HumDiv. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; the Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.962114Disordered0.967463Binding0.3450.8330.625-4.597Likely Benign0.157Likely BenignLikely Benign0.331Likely Benign-2.73Deleterious0.798Possibly Damaging0.283Benign5.53Benign0.24Tolerated0.31540.59391-13.4-26.04
c.3121C>T
P1041S
2D
AIThe SynGAP1 missense variant P1041S is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443673‑C‑T). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and polyPhen‑2 HumDiv. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote) also as benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.962114Disordered0.967463Binding0.3450.8330.625Conflicting 26-33443673-C-T16.20e-7-4.246Likely Benign0.121Likely BenignLikely Benign0.344Likely Benign-2.72Deleterious0.664Possibly Damaging0.283Benign5.48Benign0.11Tolerated3.7750.31990.61201-10.8-10.04
c.3122C>A
P1041H
2D
AIThe SynGAP1 missense variant P1041H is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction, and Foldetta’s protein‑folding stability result is unavailable. Overall, the majority of high‑confidence tools predict a benign impact, and there is no conflict with ClinVar status because the variant has not been reported there. Thus, based on current predictions, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.962114Disordered0.967463Binding0.3450.8330.625-5.312Likely Benign0.377AmbiguousLikely Benign0.476Likely Benign-3.32Deleterious0.999Probably Damaging0.917Probably Damaging5.45Benign0.03Affected0.18830.54340-2-1.640.02
c.3122C>G
P1041R
2D
AIThe SynGAP1 missense variant P1041R is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. The AlphaMissense‑Default result is uncertain, and no Foldetta stability data are available, so these are treated as unavailable. Overall, six tools support a benign classification while three support pathogenicity, and the high‑accuracy AlphaMissense‑Optimized and SGM Consensus both predict benign. Therefore, the variant is most likely benign based on the current predictions, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.962114Disordered0.967463Binding0.3450.8330.625-4.808Likely Benign0.545AmbiguousLikely Benign0.443Likely Benign-3.33Deleterious0.986Probably Damaging0.787Possibly Damaging5.46Benign0.07Tolerated0.14010.42920-2-2.959.07
c.3122C>T
P1041L
2D
AIThe SynGAP1 missense variant P1041L is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and polyPhen‑2 HumDiv. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also resolves to benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact. This conclusion does not contradict ClinVar, which has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.962114Disordered0.967463Binding0.3450.8330.625-4.901Likely Benign0.399AmbiguousLikely Benign0.403Likely Benign-3.14Deleterious0.905Possibly Damaging0.375Benign5.46Benign1.00Tolerated0.23570.6664-3-35.416.04
c.2365C>A
P789T
2D
AIThe SynGAP1 P789T missense variant has no ClinVar entry and is not present in gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, ESM1b, and AlphaMissense‑Optimized, while pathogenic predictions arise from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. AlphaMissense‑Default remains uncertain. High‑accuracy assessments further clarify the variant’s likely effect: AlphaMissense‑Optimized predicts a benign outcome, whereas the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—leans pathogenic (2 pathogenic vs. 1 benign). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status is unavailable. Overall, the preponderance of evidence from both general and high‑accuracy tools indicates that P789T is most likely pathogenic, and this assessment does not contradict any ClinVar status, as none is reported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.963420Disordered0.541575Binding0.3980.9030.750-5.242Likely Benign0.356AmbiguousLikely Benign0.224Likely Benign-4.77Deleterious1.000Probably Damaging0.999Probably Damaging2.06Pathogenic0.00Affected0.13710.38370-10.93.99
c.2365C>G
P789A
2D
AIThe SynGAP1 P789A missense variant is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized; pathogenic predictions come from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. The SGM Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a tie (2 benign, 2 pathogenic) and is therefore inconclusive. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, while the SGM Consensus remains inconclusive and Foldetta data are unavailable. Overall, the majority of tools (five out of nine) predict pathogenicity, but the presence of four benign predictions and the inconclusive high‑accuracy results suggest uncertainty. The variant is most likely pathogenic based on the current predictions, and this assessment does not contradict any ClinVar annotation because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.963420Disordered0.541575Binding0.3980.9030.750-4.777Likely Benign0.235Likely BenignLikely Benign0.258Likely Benign-4.92Deleterious0.999Probably Damaging0.998Probably Damaging2.11Pathogenic0.00Affected0.31200.30521-13.4-26.04
c.2365C>T
P789S
2D
AIThe SynGAP1 P789S variant has no ClinVar entry (ClinVar status: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that classify it as benign include REVEL, ESM1b, and AlphaMissense‑Optimized, whereas pathogenic predictions come from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—predicts pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the balance of evidence leans toward pathogenicity, with five tools supporting a deleterious effect versus three supporting benignity. This prediction does not contradict ClinVar status, which currently has no classification for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.963420Disordered0.541575Binding0.3980.9030.750-4.793Likely Benign0.409AmbiguousLikely Benign0.221Likely Benign-4.64Deleterious1.000Probably Damaging0.999Probably Damaging2.19Pathogenic0.00Affected0.31000.34361-10.8-10.04
c.2366C>A
P789Q
2D
AIThe SynGAP1 P789Q missense change is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) favors pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a pathogenic impact, and this conclusion does not contradict the ClinVar status, which currently has no classification for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.963420Disordered0.541575Binding0.3980.9030.750-5.191Likely Benign0.465AmbiguousLikely Benign0.235Likely Benign-4.53Deleterious1.000Probably Damaging0.999Probably Damaging2.03Pathogenic0.00Affected0.12840.32150-1-1.931.01
c.2366C>G
P789R
2D
AIThe SynGAP1 missense variant P789R is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. In contrast, the majority of tools predict a pathogenic impact: PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default all indicate pathogenicity, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also classifies the variant as Likely Pathogenic. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM‑Consensus remains Likely Pathogenic; Foldetta results are unavailable. Overall, the preponderance of evidence points to a pathogenic effect, and this conclusion does not contradict the absence of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicSH3-binding motif0.963420Disordered0.541575Binding0.3980.9030.750-2.503Likely Benign0.668Likely PathogenicLikely Benign0.354Likely Benign-5.04Deleterious1.000Probably Damaging0.999Probably Damaging2.03Pathogenic0.00Affected0.13530.21290-2-2.959.07
c.2366C>T
P789L
2D
AIThe SynGAP1 P789L missense variant has no ClinVar entry and is not reported in gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, ESM1b, and AlphaMissense‑Optimized, while pathogenic predictions arise from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. AlphaMissense‑Default remains uncertain. High‑accuracy assessments further refine the picture: AlphaMissense‑Optimized predicts benign, whereas the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—leans pathogenic (2 pathogenic vs. 1 benign). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence (five pathogenic vs. three benign predictions, with the SGM Consensus supporting pathogenicity) indicates that P789L is most likely pathogenic, and this assessment does not contradict any ClinVar status, as none is currently assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.963420Disordered0.541575Binding0.3980.9030.750-4.623Likely Benign0.457AmbiguousLikely Benign0.303Likely Benign-5.91Deleterious1.000Probably Damaging0.999Probably Damaging2.02Pathogenic0.00Affected0.19580.4866-3-35.416.04
c.3139T>A
S1047T
2D
AIThe SynGAP1 missense variant S1047T is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign status. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.963420Disordered0.933764Binding0.4090.9090.750-4.222Likely Benign0.070Likely BenignLikely Benign0.029Likely Benign0.23Neutral0.069Benign0.049Benign2.63Benign0.63Tolerated0.17960.6265110.114.03
c.3139T>C
S1047P
2D
AIThe SynGAP1 missense variant S1047P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only SIFT indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also classifies the variant as likely benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions points to a benign impact, and this is consistent with the lack of any ClinVar pathogenic annotation. Thus, the variant is most likely benign, and this does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.963420Disordered0.933764Binding0.4090.9090.750-2.415Likely Benign0.076Likely BenignLikely Benign0.064Likely Benign0.52Neutral0.001Benign0.001Benign2.62Benign0.03Affected0.23730.56561-1-0.810.04
c.3139T>G
S1047A
2D
AIThe SynGAP1 missense variant S1047A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable. Overall, the consensus of all available predictions indicates that the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.963420Disordered0.933764Binding0.4090.9090.750-3.503Likely Benign0.060Likely BenignLikely Benign0.040Likely Benign-0.50Neutral0.001Benign0.002Benign2.65Benign0.07Tolerated0.44600.5548112.6-16.00
c.3140C>T
S1047L
2D
AIThe SynGAP1 missense variant S1047L is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443692‑C‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores benign, and the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates benign. Foldetta stability analysis is not available for this variant. Overall, the preponderance of computational evidence points to a benign effect, which does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.963420Disordered0.933764Binding0.4090.9090.750Uncertain 16-33443692-C-T16.20e-7-4.062Likely Benign0.132Likely BenignLikely Benign0.032Likely Benign-0.63Neutral0.144Benign0.058Benign2.60Benign0.02Affected3.7750.15750.5555-2-34.626.08
c.2368A>C
T790P
2D
AIThe SynGAP1 missense variant T790P has no ClinVar entry (ClinVar status: not reported) but is present in gnomAD (ID 6‑33442920‑A‑C). Prediction tools that agree on a benign effect include REVEL, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 benign vs 2 pathogenic), and Foldetta results are unavailable. Overall, the majority of conventional tools (5 pathogenic vs 4 benign) lean toward a pathogenic interpretation, while the single high‑accuracy tool suggests benign. Thus, the variant is most likely pathogenic based on the prevailing predictions, and this does not contradict the ClinVar status, which currently has no classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.964893Disordered0.509280Binding0.3850.8960.8756-33442920-A-C-3.564Likely Benign0.088Likely BenignLikely Benign0.250Likely Benign-3.55Deleterious0.999Probably Damaging0.997Probably Damaging2.25Pathogenic0.01Affected3.6460.21470.4748-10-0.9-3.99
c.2368A>G
T790A
2D
AIThe SynGAP1 T790A missense change is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized; pathogenic predictions come from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. The SGM Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (2 benign vs. 2 pathogenic). High‑accuracy assessments show AlphaMissense‑Optimized labeling the variant as benign, while the SGM Consensus remains inconclusive and Foldetta data are unavailable. Overall, the majority of standard predictors indicate pathogenicity, but the single high‑accuracy tool that is available suggests a benign effect, and no high‑accuracy tool provides a definitive pathogenic verdict. Consequently, the variant is most likely pathogenic according to the bulk of predictions, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.964893Disordered0.509280Binding0.3850.8960.875-4.337Likely Benign0.096Likely BenignLikely Benign0.167Likely Benign-2.64Deleterious0.992Probably Damaging0.989Probably Damaging2.35Pathogenic0.02Affected0.41570.4207102.5-30.03
c.2368A>T
T790S
2D
AIThe SynGAP1 missense variant T790S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized returns Benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for T790S, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.964893Disordered0.509280Binding0.3850.8960.875-3.914Likely Benign0.123Likely BenignLikely Benign0.125Likely Benign-1.83Neutral0.997Probably Damaging0.989Probably Damaging2.39Pathogenic0.33Tolerated3.6460.34160.444911-0.1-14.03
c.2369C>A
T790N
2D
AIThe SynGAP1 missense variant T790N is listed in ClinVar with an “Uncertain” status and is present in the gnomAD database (ID 6‑33442921‑C‑A). Prediction tools that agree on a benign effect include REVEL, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive and therefore unavailable, and Foldetta results are not reported. Overall, the majority of conventional tools (5 pathogenic vs. 4 benign) lean toward a pathogenic interpretation, while the single high‑accuracy tool suggests benign. The variant’s ClinVar status remains uncertain, so there is no contradiction with the current clinical classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.964893Disordered0.509280Binding0.3850.8960.875Conflicting 36-33442921-C-A694.28e-5-5.243Likely Benign0.276Likely BenignLikely Benign0.103Likely Benign-2.54Deleterious0.999Probably Damaging0.997Probably Damaging2.27Pathogenic0.02Affected3.6460.14460.465300-2.813.00
c.2369C>G
T790S
2D
AIThe SynGAP1 missense variant T790S (ClinVar ID 1020340) is listed as Uncertain in ClinVar and is not reported in gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus, which is derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN. Pathogenic predictions come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict the ClinVar status of Uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.964893Disordered0.509280Binding0.3850.8960.875Uncertain 2-3.914Likely Benign0.123Likely BenignLikely Benign0.134Likely Benign-1.83Neutral0.997Probably Damaging0.989Probably Damaging2.39Pathogenic0.33Tolerated3.6460.34160.444911-0.1-14.03
c.2369C>T
T790I
2D
AIThe SynGAP1 missense variant T790I is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is pathogenic. Foldetta, which would provide a protein‑folding stability estimate, has no available result for this variant. Overall, the majority of evidence points to a pathogenic impact. This conclusion does not contradict the ClinVar status, which currently has no classification for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.964893Disordered0.509280Binding0.3850.8960.875-3.556Likely Benign0.482AmbiguousLikely Benign0.190Likely Benign-3.08Deleterious0.999Probably Damaging0.997Probably Damaging2.28Pathogenic0.01Affected0.09870.54310-15.212.05
c.3118G>A
G1040S
2D
AIThe SynGAP1 missense variant G1040S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include PROVEAN, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are REVEL, polyPhen‑2 HumDiv, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence (six benign versus four pathogenic predictions) points to a benign impact for G1040S. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.964893Disordered0.973805Binding0.3320.8160.625-2.179Likely Benign0.307Likely BenignLikely Benign0.653Likely Pathogenic-1.81Neutral0.827Possibly Damaging0.375Benign-0.74Pathogenic0.02Affected0.23320.529810-0.430.03
c.3118G>C
G1040R
2D
AIThe SynGAP1 missense variant G1040R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely converge on a deleterious effect: pathogenic calls are made by REVEL, PROVEAN, polyPhen‑2 HumDiv, SIFT, FATHMM, AlphaMissense‑Default, and the SGM‑Consensus (which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Benign predictions are limited to polyPhen‑2 HumVar and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as uncertain, while the SGM‑Consensus remains pathogenic. Foldetta, a protein‑folding stability predictor, has no available result for this residue. Taken together, the majority of evidence supports a pathogenic classification, and this conclusion does not conflict with the absence of a ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.964893Disordered0.973805Binding0.3320.8160.625-2.901Likely Benign0.949Likely PathogenicAmbiguous0.704Likely Pathogenic-3.00Deleterious0.463Possibly Damaging0.194Benign-0.74Pathogenic0.00Affected0.09240.4415-3-2-4.199.14
c.3118G>T
G1040C
2D
AIThe SynGAP1 missense variant G1040C is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a deleterious effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Default all predict pathogenicity, while ESM1b and AlphaMissense‑Optimized predict a benign outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Pathogenic. High‑accuracy assessments further support this view: AlphaMissense‑Optimized reports a benign prediction, whereas the SGM‑Consensus remains Likely Pathogenic; the Foldetta stability analysis is unavailable. Overall, the preponderance of evidence from multiple in silico tools indicates that the variant is most likely pathogenic, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.964893Disordered0.973805Binding0.3320.8160.625-6.272Likely Benign0.620Likely PathogenicLikely Benign0.744Likely Pathogenic-3.04Deleterious0.999Probably Damaging0.917Probably Damaging-0.74Pathogenic0.00Affected0.11550.4556-3-32.946.09
c.3119G>A
G1040D
2D
AIThe SynGAP1 missense variant G1040D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include only ESM1b, whereas the remaining tools—REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus—predict a pathogenic impact. The high‑accuracy assessments further support this: AlphaMissense‑Optimized classifies the variant as pathogenic, the SGM‑Consensus (a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) labels it likely pathogenic, and the Foldetta stability analysis is unavailable. Overall, the preponderance of evidence indicates that G1040D is most likely pathogenic, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.964893Disordered0.973805Binding0.3320.8160.625-4.154Likely Benign0.956Likely PathogenicLikely Pathogenic0.761Likely Pathogenic-2.82Deleterious0.986Probably Damaging0.787Possibly Damaging-0.74Pathogenic0.00Affected0.16770.20421-1-3.158.04
c.3119G>C
G1040A
2D
AIThe SynGAP1 missense variant G1040A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are REVEL and FATHMM, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote among AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign prediction (2 benign vs. 1 pathogenic). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation, as the variant is not yet classified in that database.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.964893Disordered0.973805Binding0.3320.8160.625-2.625Likely Benign0.409AmbiguousLikely Benign0.606Likely Pathogenic-1.65Neutral0.114Benign0.030Benign-0.74Pathogenic0.30Tolerated0.32460.5331102.214.03
c.3119G>T
G1040V
2D
AIThe SynGAP1 missense variant G1040V is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443671‑G‑T). Prediction tools that agree on a benign effect are ESM1b and AlphaMissense‑Optimized; those that predict a pathogenic effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and the SGM‑Consensus score (Likely Pathogenic). High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Pathogenic, and Foldetta results are unavailable. Overall, the majority of predictions indicate a pathogenic impact, and this is not in conflict with the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.964893Disordered0.973805Binding0.3320.8160.625Uncertain 16-33443671-G-T42.48e-6-3.453Likely Benign0.645Likely PathogenicLikely Benign0.774Likely Pathogenic-2.89Deleterious0.827Possibly Damaging0.456Possibly Damaging-0.74Pathogenic0.01Affected3.7750.12390.4213-1-34.642.08
c.2371A>C
K791Q
2D
AIThe SynGAP1 missense variant K791Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv flags the variant as pathogenic, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports it as Likely Benign. High‑accuracy assessments confirm this trend: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that K791Q is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.966441Disordered0.478670Uncertain0.3560.8960.875-3.418Likely Benign0.195Likely BenignLikely Benign0.081Likely Benign-0.09Neutral0.802Possibly Damaging0.335Benign4.17Benign0.46Tolerated0.53220.1159Weaken110.4-0.04
c.2371A>G
K791E
2D
AIThe SynGAP1 missense variant K791E is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools uniformly favor a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) indicates likely benign; Foldetta results are unavailable. Taken together, the preponderance of evidence supports a benign impact for K791E, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.966441Disordered0.478670Uncertain0.3560.8960.875-3.823Likely Benign0.465AmbiguousLikely Benign0.053Likely Benign-0.58Neutral0.451Benign0.193Benign4.22Benign0.65Tolerated0.48290.0876010.40.94
c.2372A>C
K791T
2D
AIThe SynGAP1 missense variant K791T is listed in gnomAD (ID 6‑33442924‑A‑C) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). No tool predicts pathogenicity. The high‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign outcome, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence overwhelmingly supports a benign classification, and this is consistent with the absence of a ClinVar pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.966441Disordered0.478670Uncertain0.3560.8960.8756-33442924-A-C21.24e-6-1.578Likely Benign0.415AmbiguousLikely Benign0.033Likely Benign-0.92Neutral0.032Benign0.017Benign4.17Benign0.16Tolerated3.6460.27340.3340-103.2-27.07
c.2372A>G
K791R
2D
AIThe SynGAP1 missense variant K791R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv flags the variant as pathogenic, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports it as Likely Benign. High‑accuracy assessments confirm this trend: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta results are not available, so they do not influence the assessment. Overall, the preponderance of evidence supports a benign classification for K791R, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.966441Disordered0.478670Uncertain0.3560.8960.875-2.359Likely Benign0.082Likely BenignLikely Benign0.028Likely Benign-0.96Neutral0.802Possibly Damaging0.249Benign4.14Benign0.50Tolerated0.55200.1223Weaken32-0.628.01
c.2372A>T
K791M
2D
AIThe SynGAP1 missense variant K791M is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Default predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the balance of evidence, including the consensus and high‑accuracy predictions, points to a benign impact for K791M. This conclusion is not contradicted by ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.966441Disordered0.478670Uncertain0.3560.8960.875-3.898Likely Benign0.653Likely PathogenicLikely Benign0.050Likely Benign-1.12Neutral0.934Possibly Damaging0.558Possibly Damaging4.10Benign0.04Affected0.16420.41790-15.83.02
c.2373G>C
K791N
2D
AIThe SynGAP1 missense variant K791N is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain, and Foldetta (combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Overall, the majority of high‑accuracy predictions (SGM‑Consensus, AlphaMissense‑Optimized uncertain, Foldetta unavailable) lean toward a benign interpretation, with only two pathogenic calls. Thus, based on the current computational evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.966441Disordered0.478670Uncertain0.3560.8960.875-4.001Likely Benign0.794Likely PathogenicAmbiguous0.027Likely Benign-1.26Neutral0.666Possibly Damaging0.267Benign4.14Benign0.13Tolerated0.45780.1354100.4-14.07
c.2373G>T
K791N
2D
AIThe SynGAP1 missense variant K791N is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Overall, the majority of high‑accuracy predictions (including the SGM‑Consensus) indicate a benign impact, and there is no conflict with ClinVar status. Thus, based on the current computational evidence, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.966441Disordered0.478670Uncertain0.3560.8960.875-4.001Likely Benign0.794Likely PathogenicAmbiguous0.027Likely Benign-1.26Neutral0.666Possibly Damaging0.267Benign4.14Benign0.13Tolerated0.45780.1354100.4-14.07
c.3199C>A
P1067T
2D
AIThe SynGAP1 missense variant P1067T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. In contrast, polyPhen‑2 HumDiv and SIFT predict pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.966441Disordered0.975099Binding0.4590.9070.875-4.898Likely Benign0.084Likely BenignLikely Benign0.062Likely Benign-1.94Neutral0.827Possibly Damaging0.375Benign2.79Benign0.04Affected0.14490.61320-10.93.99
c.3199C>G
P1067A
2D
AIThe SynGAP1 missense variant P1067A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic outcome, representing the sole discordant prediction. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the preponderance of evidence supports a benign classification for P1067A, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.966441Disordered0.975099Binding0.4590.9070.875-4.639Likely Benign0.052Likely BenignLikely Benign0.073Likely Benign-2.05Neutral0.664Possibly Damaging0.283Benign2.87Benign0.07Tolerated0.30970.53221-13.4-26.04
c.3199C>T
P1067S
2D
AIThe SynGAP1 missense variant P1067S is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Based on the collective predictions, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.966441Disordered0.975099Binding0.4590.9070.875-4.673Likely Benign0.073Likely BenignLikely Benign0.079Likely Benign-1.43Neutral0.271Benign0.054Benign2.91Benign0.48Tolerated0.30860.57531-10.8-10.04
c.3200C>A
P1067Q
2D
AIThe SynGAP1 missense variant P1067Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. In contrast, polyPhen‑2 HumDiv and SIFT predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign status. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign effect for P1067Q, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.966441Disordered0.975099Binding0.4590.9070.875-4.767Likely Benign0.114Likely BenignLikely Benign0.136Likely Benign-2.39Neutral0.463Possibly Damaging0.087Benign2.84Benign0.01Affected0.13690.54150-1-1.931.01
c.3200C>G
P1067R
2D
AIThe SynGAP1 missense variant P1067R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also predicts benign, while Foldetta’s stability analysis is unavailable. Taken together, the majority of reliable predictors and the high‑accuracy tools indicate a benign impact. This conclusion is not contradicted by ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.966441Disordered0.975099Binding0.4590.9070.875-4.878Likely Benign0.376AmbiguousLikely Benign0.167Likely Benign-2.74Deleterious0.971Probably Damaging0.580Possibly Damaging2.78Benign0.01Affected0.13000.36510-2-2.959.07
c.3200C>T
P1067L
2D
AIThe SynGAP1 missense variant P1067L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of predictions and the consensus analysis indicate a benign impact. This conclusion is consistent with the lack of ClinVar evidence and does not contradict any existing database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.966441Disordered0.975099Binding0.4590.9070.875-4.461Likely Benign0.107Likely BenignLikely Benign0.157Likely Benign-3.01Deleterious0.951Possibly Damaging0.619Possibly Damaging2.76Benign0.01Affected0.20470.6198-3-35.416.04
c.3196C>A
P1066T
2D
AIThe SynGAP1 missense variant P1066T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. Foldetta results are unavailable. Overall, the majority of computational evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.967676Disordered0.968838Binding0.4030.9130.875-5.973Likely Benign0.082Likely BenignLikely Benign0.167Likely Benign-2.61Deleterious0.996Probably Damaging0.928Probably Damaging2.66Benign0.00Affected0.16520.72400-10.93.99
c.3196C>G
P1066A
2D
AIThe SynGAP1 missense variant P1066A is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.967676Disordered0.968838Binding0.4030.9130.875-4.856Likely Benign0.050Likely BenignLikely Benign0.149Likely Benign-2.35Neutral0.972Probably Damaging0.802Possibly Damaging2.78Benign0.00Affected0.32280.60421-13.4-26.04
c.3196C>T
P1066S
2D
AIThe SynGAP1 missense variant P1066S is listed in ClinVar as Pathogenic (ClinVar ID 1343237.0) and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; a Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, which contradicts the ClinVar pathogenic classification. Thus, based on current predictions, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.967676Disordered0.968838Binding0.4030.9130.875Likely Pathogenic 1-4.746Likely Benign0.070Likely BenignLikely Benign0.145Likely Benign-2.47Neutral0.972Probably Damaging0.850Possibly Damaging2.74Benign0.00Affected4.3220.33040.63531-10.8-10.04
c.3197C>A
P1066H
2D
AIThe SynGAP1 missense variant P1066H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.967676Disordered0.968838Binding0.4030.9130.875-6.034Likely Benign0.185Likely BenignLikely Benign0.146Likely Benign-2.90Deleterious1.000Probably Damaging0.975Probably Damaging2.61Benign0.00Affected0.19840.58610-2-1.640.02
c.3197C>G
P1066R
2D
AIThe SynGAP1 missense variant P1066R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, tools that predict a pathogenic outcome are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.967676Disordered0.968838Binding0.4030.9130.875-5.154Likely Benign0.292Likely BenignLikely Benign0.176Likely Benign-2.89Deleterious0.992Probably Damaging0.873Possibly Damaging2.63Benign0.00Affected0.15230.47420-2-2.959.07
c.3197C>T
P1066L
2D
AIThe SynGAP1 missense variant P1066L is listed in ClinVar as a benign variant (ClinVar ID 951518.0) and is present in gnomAD (ID 6‑33443749‑C‑T). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, which is consistent with the ClinVar classification and does not contradict the reported status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.967676Disordered0.968838Binding0.4030.9130.875Likely Benign 16-33443749-C-T148.71e-6-5.478Likely Benign0.092Likely BenignLikely Benign0.173Likely Benign-3.68Deleterious0.996Probably Damaging0.903Possibly Damaging2.72Benign0.00Affected4.3220.22690.6780-3-35.416.04
c.3115A>C
I1039L
2D
AIThe SynGAP1 missense variant I1039L is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, is not available for this variant. Overall, the consensus of all available predictions strongly supports a benign classification, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.979204Binding0.2920.8060.625-2.035Likely Benign0.269Likely BenignLikely Benign0.083Likely Benign-0.14Neutral0.264Benign0.048Benign2.82Benign0.98Tolerated0.10570.460522-0.70.00
c.3115A>G
I1039V
2D
AIThe SynGAP1 missense variant I1039V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.979204Binding0.2920.8060.625-2.455Likely Benign0.164Likely BenignLikely Benign0.060Likely Benign0.21Neutral0.264Benign0.048Benign2.76Benign0.41Tolerated0.14050.411243-0.3-14.03
c.3115A>T
I1039F
2D
AIThe SynGAP1 missense variant I1039F is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign interpretation: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict benign, while the majority of other predictors (polyPhen‑2 HumDiv and HumVar) indicate pathogenic. When predictions are grouped by agreement, the benign‑oriented tools outnumber the pathogenic ones, and the single uncertain call from AlphaMissense‑Default does not alter this balance. High‑accuracy assessments reinforce the benign trend: AlphaMissense‑Optimized scores the variant as benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports it as Likely Benign. Foldetta data are unavailable. Overall, the computational evidence overwhelmingly supports a benign effect, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.979204Binding0.2920.8060.625-2.872Likely Benign0.545AmbiguousLikely Benign0.124Likely Benign-1.16Neutral0.925Possibly Damaging0.510Possibly Damaging2.68Benign0.13Tolerated0.07100.436810-1.734.02
c.3116T>A
I1039N
2D
AIThe SynGAP1 missense variant I1039N has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. AlphaMissense‑Optimized is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar status (none is present). Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.979204Binding0.2920.8060.625-3.469Likely Benign0.951Likely PathogenicAmbiguous0.155Likely Benign-1.24Neutral0.011Benign0.010Benign2.67Benign0.02Affected0.11510.1311-2-3-8.00.94
c.3116T>C
I1039T
2D
AIThe SynGAP1 missense variant I1039T is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443668‑T‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM; the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports a likely benign outcome. Only AlphaMissense‑Default predicts a pathogenic effect. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign, while a Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this is consistent with the ClinVar “Uncertain” classification rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.979204Binding0.2920.8060.625Uncertain 26-33443668-T-C127.43e-6-2.465Likely Benign0.645Likely PathogenicLikely Benign0.193Likely Benign0.45Neutral0.004Benign0.008Benign2.75Benign0.10Tolerated3.7750.12480.2293-10-5.2-12.05
c.3116T>G
I1039S
2D
AIThe SynGAP1 missense variant I1039S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM all classify the substitution as benign. In contrast, SIFT and AlphaMissense‑Default predict a pathogenic impact. The high‑accuracy AlphaMissense‑Optimized score is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. No Foldetta stability assessment is available. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.979204Binding0.2920.8060.625-1.688Likely Benign0.829Likely PathogenicAmbiguous0.171Likely Benign-0.20Neutral0.032Benign0.008Benign2.76Benign0.03Affected0.29170.1294-1-2-5.3-26.08
c.3117T>G
I1039M
2D
AIThe SynGAP1 missense variant I1039M is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for I1039M, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.979204Binding0.2920.8060.625-3.444Likely Benign0.292Likely BenignLikely Benign0.116Likely Benign-0.38Neutral0.977Probably Damaging0.721Possibly Damaging2.68Benign0.16Tolerated0.09260.439221-2.618.03
c.3124C>A
Q1042K
2D
AIThe SynGAP1 missense variant Q1042K is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the collective predictions strongly suggest that the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.959333Binding0.3100.8460.625-4.331Likely Benign0.498AmbiguousLikely Benign0.304Likely Benign-1.52Neutral0.224Benign0.091Benign5.44Benign0.13Tolerated0.23380.520211-0.40.04
c.3124C>G
Q1042E
2D
AIThe SynGAP1 missense variant Q1042E is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.959333Binding0.3100.8460.625-4.231Likely Benign0.262Likely BenignLikely Benign0.267Likely Benign-1.12Neutral0.224Benign0.077Benign5.44Benign0.15Tolerated0.20420.3276220.00.98
c.3125A>C
Q1042P
2D
AIThe SynGAP1 missense variant Q1042P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only polyPhen‑2 HumDiv indicates a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Overall, the consensus of the available predictions points to a benign effect, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.959333Binding0.3100.8460.625-2.085Likely Benign0.060Likely BenignLikely Benign0.461Likely Benign-0.73Neutral0.586Possibly Damaging0.223Benign5.42Benign0.31Tolerated0.23360.57620-11.9-31.01
c.3125A>G
Q1042R
2D
AIThe SynGAP1 missense variant Q1042R is listed in ClinVar (ID 2662705.0) with an “Uncertain” clinical significance and is present in gnomAD (variant ID 6‑33443677‑A‑G). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are unavailable. Overall, the majority of evidence supports a benign impact for Q1042R, and this conclusion does not contradict the ClinVar status, which remains uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.959333Binding0.3100.8460.625Uncertain 26-33443677-A-G21.24e-6-2.928Likely Benign0.413AmbiguousLikely Benign0.300Likely Benign-1.39Neutral0.586Possibly Damaging0.120Benign5.48Benign0.12Tolerated3.7750.19290.388711-1.028.06
c.3125A>T
Q1042L
2D
AIThe SynGAP1 missense variant Q1042L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.959333Binding0.3100.8460.625-3.796Likely Benign0.203Likely BenignLikely Benign0.338Likely Benign-2.47Neutral0.369Benign0.120Benign5.47Benign0.05Affected0.14690.6276-2-27.3-14.97
c.3126G>C
Q1042H
2D
AIThe SynGAP1 missense variant Q1042H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.959333Binding0.3100.8460.625-4.258Likely Benign0.335Likely BenignLikely Benign0.302Likely Benign-1.54Neutral0.938Possibly Damaging0.596Possibly Damaging5.42Benign0.03Affected0.22070.4671300.39.01
c.3126G>T
Q1042H
2D
AIThe SynGAP1 missense variant Q1042H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized returns Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.959333Binding0.3100.8460.625-4.258Likely Benign0.335Likely BenignLikely Benign0.302Likely Benign-1.54Neutral0.938Possibly Damaging0.596Possibly Damaging5.42Benign0.03Affected0.22070.4671300.39.01
c.3136C>A
P1046T
2D
AIThe SynGAP1 missense variant P1046T is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; the Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.970265Disordered0.942366Binding0.3640.8980.750-5.249Likely Benign0.068Likely BenignLikely Benign0.052Likely Benign-1.18Neutral0.411Benign0.131Benign2.37Pathogenic0.21Tolerated0.14300.59340-10.93.99
c.3136C>G
P1046A
2D
AIThe SynGAP1 missense variant P1046A is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443688‑C‑G). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; a Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.970265Disordered0.942366Binding0.3640.8980.750Uncertain 16-33443688-C-G16.20e-7-3.246Likely Benign0.048Likely BenignLikely Benign0.041Likely Benign-1.67Neutral0.001Benign0.008Benign2.39Pathogenic0.29Tolerated3.7750.29760.5358-113.4-26.04
c.3136C>T
P1046S
2D
AIThe SynGAP1 missense variant P1046S is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; the Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of computational evidence indicates a benign effect, and this consensus does not contradict any ClinVar status (none is available). Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.970265Disordered0.942366Binding0.3640.8980.750-3.909Likely Benign0.059Likely BenignLikely Benign0.096Likely Benign-0.72Neutral0.126Benign0.096Benign2.39Pathogenic0.70Tolerated0.29290.57441-10.8-10.04
c.3137C>A
P1046H
2D
AIThe SynGAP1 missense variant P1046H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for P1046H. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.970265Disordered0.942366Binding0.3640.8980.750-5.715Likely Benign0.148Likely BenignLikely Benign0.035Likely Benign-1.64Neutral0.832Possibly Damaging0.670Possibly Damaging2.33Pathogenic0.07Tolerated0.15850.52500-2-1.640.02
c.3137C>G
P1046R
2D
AIThe SynGAP1 missense variant P1046R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) all classify the change as benign or likely benign. Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized returns a benign prediction, and the SGM‑Consensus also indicates a likely benign status. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.970265Disordered0.942366Binding0.3640.8980.750-4.929Likely Benign0.222Likely BenignLikely Benign0.077Likely Benign-1.79Neutral0.002Benign0.005Benign2.38Pathogenic0.07Tolerated0.12670.38410-2-2.959.07
c.3137C>T
P1046L
2D
AIThe SynGAP1 missense variant P1046L is reported in gnomAD (ID 6‑33443689‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. In contrast, SIFT and FATHMM predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign; Foldetta results are unavailable. Overall, the preponderance of evidence from multiple independent predictors and the consensus analysis points to a benign classification. This conclusion is consistent with the absence of a ClinVar pathogenic report, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.970265Disordered0.942366Binding0.3640.8980.7506-33443689-C-T16.20e-7-5.022Likely Benign0.116Likely BenignLikely Benign0.100Likely Benign-2.11Neutral0.001Benign0.005Benign2.35Pathogenic0.05Affected3.7750.20360.6442-3-35.416.04
c.2377A>C
K793Q
2D
AIThe SynGAP1 missense variant K793Q is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign outcome, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign status. Foldetta results are unavailable, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.971072Disordered0.426071Uncertain0.3440.9010.875-2.838Likely Benign0.256Likely BenignLikely Benign0.032Likely Benign-0.83Neutral0.174Benign0.099Benign4.13Benign0.06Tolerated0.52760.1540Weaken110.4-0.04
c.2377A>G
K793E
2D
AIThe SynGAP1 missense variant K793E is listed in gnomAD (ID 6‑33442929‑A‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.971072Disordered0.426071Uncertain0.3440.9010.8756-33442929-A-G-4.233Likely Benign0.555AmbiguousLikely Benign0.035Likely Benign-1.05Neutral0.001Benign0.006Benign4.17Benign0.05Affected4.0730.46700.1499100.40.94
c.2378A>C
K793T
2D
AIThe SynGAP1 missense variant K793T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. Only SIFT predicts a pathogenic outcome, and AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) indicates likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for K793T, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.971072Disordered0.426071Uncertain0.3440.9010.875-3.861Likely Benign0.393AmbiguousLikely Benign0.066Likely Benign-1.47Neutral0.174Benign0.123Benign4.12Benign0.03Affected0.27560.34730-13.2-27.07
c.2378A>G
K793R
2D
AIThe SynGAP1 missense variant K793R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that assess sequence conservation and functional impact all converge on a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. No tool in the dataset indicates pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign,” while Foldetta results are unavailable. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.971072Disordered0.426071Uncertain0.3440.9010.875-2.789Likely Benign0.113Likely BenignLikely Benign0.026Likely Benign-0.29Neutral0.001Benign0.003Benign4.18Benign0.22Tolerated0.52700.1657Weaken32-0.628.01
c.2378A>T
K793M
2D
AIThe SynGAP1 K793M missense change is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is also benign; Foldetta results are not available. Overall, the balance of evidence, including the two high‑accuracy tools, points to a benign effect for K793M. This conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.971072Disordered0.426071Uncertain0.3440.9010.875-4.762Likely Benign0.570Likely PathogenicLikely Benign0.073Likely Benign-1.49Neutral0.820Possibly Damaging0.601Possibly Damaging4.06Benign0.01Affected0.16740.40200-15.83.02
c.2379G>C
K793N
2D
AIThe SynGAP1 missense variant K793N is catalogued in gnomAD (6‑33442931‑G‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all classify it as benign, and the SGM‑Consensus score (Likely Benign) supports this view. Only AlphaMissense‑Default predicts pathogenicity. High‑accuracy assessments further reinforce the benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields a benign classification. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that K793N is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.971072Disordered0.426071Uncertain0.3440.9010.8756-33442931-G-C42.48e-6-5.162Likely Benign0.632Likely PathogenicLikely Benign0.040Likely Benign1.18Neutral0.174Benign0.135Benign4.13Benign0.47Tolerated4.0730.44290.1976010.4-14.07
c.2379G>T
K793N
2D
AIThe SynGAP1 missense variant K793N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. Only AlphaMissense‑Default predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is also benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.971072Disordered0.426071Uncertain0.3440.9010.875-5.162Likely Benign0.632Likely PathogenicLikely Benign0.040Likely Benign1.18Neutral0.174Benign0.135Benign4.13Benign0.47Tolerated4.0730.44290.1976010.4-14.07
c.2383C>A
P795T
2D
AIThe SynGAP1 missense variant P795T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity, and the only uncertain result comes from ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign; Foldetta results are not available. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.972450Disordered0.410339Uncertain0.4570.9030.875-7.030In-Between0.060Likely BenignLikely Benign0.068Likely Benign-0.63Neutral0.036Benign0.026Benign4.26Benign0.09Tolerated0.17130.63810-10.93.99
c.2383C>G
P795A
2D
AIThe SynGAP1 missense variant P795A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; no tool predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly suggests that P795A is most likely benign, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.972450Disordered0.410339Uncertain0.4570.9030.875-5.348Likely Benign0.049Likely BenignLikely Benign0.053Likely Benign-0.52Neutral0.016Benign0.011Benign4.32Benign0.16Tolerated0.36720.53711-13.4-26.04
c.2383C>T
P795S
2D
AIThe SynGAP1 missense variant P795S is catalogued in gnomAD (6‑33442935‑C‑T) but has no entry in ClinVar. Across the spectrum of in‑silico predictors, every tool listed—REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—consistently scores the variant as benign. No pathogenic predictions are reported. Grouping by agreement, all available tools fall into the benign category, with no tools indicating pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates likely benign. Foldetta results are not provided, so they are treated as unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.972450Disordered0.410339Uncertain0.4570.9030.8756-33442935-C-T16.20e-7-5.846Likely Benign0.067Likely BenignLikely Benign0.056Likely Benign-0.23Neutral0.001Benign0.002Benign4.30Benign0.24Tolerated4.3220.35170.5766-110.8-10.04
c.2384C>A
P795H
2D
AIThe SynGAP1 missense variant P795H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT predict a pathogenic outcome. ESM1b is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.972450Disordered0.410339Uncertain0.4570.9030.875-7.717In-Between0.121Likely BenignLikely Benign0.069Likely Benign-0.61Neutral0.898Possibly Damaging0.477Possibly Damaging4.24Benign0.05Affected0.19470.51840-2-1.640.02
c.2384C>G
P795R
2D
AIThe SynGAP1 missense variant P795R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only SIFT classifies the change as pathogenic, but this is the sole discordant call. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that P795R is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.972450Disordered0.410339Uncertain0.4570.9030.875-6.536Likely Benign0.221Likely BenignLikely Benign0.059Likely Benign-1.02Neutral0.290Benign0.114Benign4.25Benign0.05Affected0.14300.40650-2-2.959.07
c.2384C>T
P795L
2D
AIThe SynGAP1 missense variant P795L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a “Likely Benign” status. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) confirms a benign outcome. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the preponderance of evidence indicates that P795L is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.972450Disordered0.410339Uncertain0.4570.9030.875-2.677Likely Benign0.070Likely BenignLikely Benign0.047Likely Benign-0.45Neutral0.016Benign0.010Benign4.27Benign0.04Affected0.23720.6499-3-35.416.04
c.2827G>A
G943S
2D
AIThe SynGAP1 missense variant G943S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign. Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.973328Disordered0.860437Binding0.3720.9100.750-5.785Likely Benign0.079Likely BenignLikely Benign0.295Likely Benign0.34Neutral0.059Benign0.039Benign2.88Benign0.51Tolerated0.24820.550210-0.430.03
c.2827G>C
G943R
2D
AIThe SynGAP1 missense variant G943R is reported in gnomAD (variant ID 6-33443379‑G‑C) but has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity; only ESM1b is uncertain. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions strongly supports a benign classification, and this is consistent with the absence of a ClinVar pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.973328Disordered0.860437Binding0.3720.9100.7506-33443379-G-C16.20e-7-7.159In-Between0.335Likely BenignLikely Benign0.308Likely Benign1.00Neutral0.411Benign0.062Benign2.86Benign0.94Tolerated4.3240.09760.4933-2-3-4.199.14
c.2827G>T
G943C
2D
AIThe SynGAP1 missense variant G943C is not reported in ClinVar and has no entries in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which itself is “Likely Benign”). In contrast, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b all predict a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta stability analysis is unavailable. Overall, the majority of evidence—including the consensus and high‑accuracy tools—points to a benign impact. Thus, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.973328Disordered0.860437Binding0.3720.9100.750-9.822Likely Pathogenic0.108Likely BenignLikely Benign0.356Likely Benign-0.94Neutral0.938Possibly Damaging0.649Possibly Damaging2.84Benign0.10Tolerated0.14250.4439-3-32.946.09
c.2828G>A
G943D
2D
AIThe SynGAP1 missense variant G943D is not reported in ClinVar and is absent from gnomAD. In silico predictors that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; ESM1b is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Taken together, the overwhelming majority of predictions indicate a benign effect, and this conclusion does not contradict any ClinVar status (none is assigned). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.973328Disordered0.860437Binding0.3720.9100.750-7.951In-Between0.304Likely BenignLikely Benign0.296Likely Benign-0.28Neutral0.224Benign0.113Benign2.85Benign0.11Tolerated0.19040.28261-1-3.158.04
c.2828G>C
G943A
2D
AIThe SynGAP1 missense variant G943A is reported in gnomAD (ID 6‑33443380‑G‑C) but has no ClinVar entry. All available in silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Based on the unanimous benign predictions and lack of ClinVar pathogenicity, the variant is most likely benign and does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.973328Disordered0.860437Binding0.3720.9100.7506-33443380-G-C31.86e-6-6.684Likely Benign0.070Likely BenignLikely Benign0.274Likely Benign0.10Neutral0.001Benign0.002Benign2.87Benign0.89Tolerated4.3240.34150.4957012.214.03
c.2828G>T
G943V
2D
AIThe SynGAP1 missense variant G943V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. The only tool with an uncertain outcome is ESM1b, which does not alter the overall consensus. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign classification. High‑accuracy predictors corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are not available. Taken together, the evidence overwhelmingly supports a benign interpretation, and there is no conflict with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.973328Disordered0.860437Binding0.3720.9100.750-7.658In-Between0.092Likely BenignLikely Benign0.265Likely Benign-0.43Neutral0.224Benign0.062Benign2.85Benign0.16Tolerated0.13990.3507-1-34.642.08
c.2374G>A
E792K
2D
AIThe SynGAP1 missense variant E792K is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and AlphaMissense‑Default. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.974374Disordered0.452261Uncertain0.3520.8960.875-4.942Likely Benign0.753Likely PathogenicLikely Benign0.059Likely Benign-2.47Neutral0.033Benign0.017Benign3.90Benign0.01Affected0.26460.758401-0.4-0.94
c.2374G>C
E792Q
2D
AIThe SynGAP1 missense variant E792Q is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” verdict, reflecting the majority of benign calls. High‑accuracy assessments further support this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates that E792Q is most likely benign, and this conclusion does not contradict the absence of a ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.974374Disordered0.452261Uncertain0.3520.8960.875-3.782Likely Benign0.411AmbiguousLikely Benign0.052Likely Benign-1.60Neutral0.077Benign0.049Benign3.89Benign0.02Affected0.14690.7401220.0-0.98
c.2375A>C
E792A
2D
AIThe SynGAP1 missense variant E792A is catalogued in gnomAD (ID 6‑33442927‑A‑C) but has no ClinVar submission. Functional prediction tools cluster into two groups: benign (REVEL, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized) and pathogenic (PROVEAN, SIFT). The high‑accuracy AlphaMissense‑Optimized score is benign, and the SGM consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also favors benign. Foldetta, a protein‑folding stability predictor, has no available result for this residue. Overall, the preponderance of evidence points to a benign effect. This conclusion is consistent with the absence of a ClinVar pathogenic classification; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.974374Disordered0.452261Uncertain0.3520.8960.8756-33442927-A-C16.20e-7-3.248Likely Benign0.515AmbiguousLikely Benign0.060Likely Benign-3.35Deleterious0.000Benign0.001Benign3.92Benign0.01Affected3.6460.45860.7544-105.3-58.04
c.2375A>G
E792G
2D
AIThe SynGAP1 E792G missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and SIFT. AlphaMissense‑Default is uncertain. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, favors a benign outcome (2 benign vs. 1 pathogenic vote). High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus as benign, and Foldetta results are unavailable. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.974374Disordered0.452261Uncertain0.3520.8960.875-3.925Likely Benign0.353AmbiguousLikely Benign0.037Likely Benign-3.77Deleterious0.000Benign0.000Benign3.88Benign0.01Affected0.31450.60360-23.1-72.06
c.2375A>T
E792V
2D
AIThe SynGAP1 E792V missense change is not listed in ClinVar and has no allele record in gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM, while pathogenic predictions arise from PROVEAN, SIFT, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, whereas the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—yields a tie and is therefore inconclusive. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the balance of evidence leans toward a benign effect. This conclusion is consistent with the absence of a ClinVar assertion, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.974374Disordered0.452261Uncertain0.3520.8960.875-4.643Likely Benign0.640Likely PathogenicLikely Benign0.072Likely Benign-3.85Deleterious0.000Benign0.001Benign3.83Benign0.00Affected0.09870.7772-2-27.7-29.98
c.2376A>C
E792D
2D
AIThe SynGAP1 missense variant E792D is not reported in ClinVar and is absent from gnomAD. All evaluated in‑silico predictors classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. No pathogenic predictions are present. High‑accuracy tools reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise predicts likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.974374Disordered0.452261Uncertain0.3520.8960.875-3.746Likely Benign0.089Likely BenignLikely Benign0.091Likely Benign-1.06Neutral0.000Benign0.001Benign3.97Benign0.26Tolerated0.20960.5376320.0-14.03
c.2376A>T
E792D
2D
AIThe SynGAP1 missense variant E792D is not reported in ClinVar and is absent from gnomAD. All evaluated in‑silico predictors classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. No pathogenic predictions are present. High‑accuracy tools reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise predicts likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.974374Disordered0.452261Uncertain0.3520.8960.875-3.746Likely Benign0.089Likely BenignLikely Benign0.091Likely Benign-1.06Neutral0.000Benign0.001Benign3.97Benign0.26Tolerated0.20960.5376320.0-14.03
c.2899C>G
R967G
2D
AIThe SynGAP1 missense variant R967G is reported in gnomAD (ID 6‑33443451‑C‑G) and has no ClinVar entry. All evaluated in silico predictors classify it as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are unavailable. Based on the unanimous benign predictions and absence of a ClinVar pathogenic claim, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.974374Disordered0.969686Binding0.3400.8880.7506-33443451-C-G16.20e-7-2.214Likely Benign0.098Likely BenignLikely Benign0.279Likely Benign-0.93Neutral0.005Benign0.007Benign4.17Benign0.18Tolerated4.3220.31870.4070-2-34.1-99.14
c.2900G>A
R967Q
2D
AIThe SynGAP1 missense variant R967Q is listed in ClinVar as Benign (ClinVar ID 536992.0) and is present in gnomAD (6‑33443452‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, aligning with the ClinVar classification and not contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.974374Disordered0.969686Binding0.3400.8880.750Benign/Likely benign 26-33443452-G-A311.92e-5-3.057Likely Benign0.080Likely BenignLikely Benign0.104Likely Benign-0.01Neutral0.994Probably Damaging0.626Possibly Damaging4.21Benign0.36Tolerated4.3220.31410.3446111.0-28.06
c.2900G>C
R967P
2D
AIThe SynGAP1 missense variant R967P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect for R967P, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.974374Disordered0.969686Binding0.3400.8880.750-2.506Likely Benign0.132Likely BenignLikely Benign0.175Likely Benign-0.76Neutral0.996Probably Damaging0.828Possibly Damaging4.14Benign0.17Tolerated0.21450.55330-22.9-59.07
c.2900G>T
R967L
2D
AIThe SynGAP1 missense variant R967L is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443452‑G‑T). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for R967L, which does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.974374Disordered0.969686Binding0.3400.8880.750Uncertain 16-33443452-G-T16.20e-7-3.496Likely Benign0.164Likely BenignLikely Benign0.123Likely Benign-0.99Neutral0.959Probably Damaging0.586Possibly Damaging4.15Benign0.75Tolerated4.3220.19640.5093-2-38.3-43.03
c.3187G>A
G1063S
2D
AIThe SynGAP1 missense variant G1063S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign. Foldetta results are unavailable, so they do not influence the overall assessment. Consequently, the variant is most likely benign based on the collective predictions, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975134Disordered0.945784Binding0.3940.9130.875-4.707Likely Benign0.067Likely BenignLikely Benign0.052Likely Benign0.20Neutral0.004Benign0.003Benign4.33Benign0.09Tolerated0.24910.570210-0.430.03
c.3187G>C
G1063R
2D
AIThe SynGAP1 missense variant G1063R is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the collective evidence strongly supports a benign classification, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975134Disordered0.945784Binding0.3940.9130.875-5.711Likely Benign0.391AmbiguousLikely Benign0.078Likely Benign0.55Neutral0.411Benign0.114Benign4.28Benign0.09Tolerated0.10370.5133-3-2-4.199.14
c.3187G>T
G1063C
2D
AIThe SynGAP1 missense variant G1063C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which itself is “Likely Benign”). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present). Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975134Disordered0.945784Binding0.3940.9130.875-8.315Likely Pathogenic0.106Likely BenignLikely Benign0.075Likely Benign-1.07Neutral0.938Possibly Damaging0.477Possibly Damaging4.19Benign0.01Affected0.14400.4639-3-32.946.09
c.3188G>A
G1063D
2D
AIThe SynGAP1 missense variant G1063D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is likely benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the computational evidence overwhelmingly supports a benign impact for G1063D, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975134Disordered0.945784Binding0.3940.9130.875-6.950Likely Benign0.367AmbiguousLikely Benign0.057Likely Benign-0.30Neutral0.411Benign0.058Benign4.24Benign0.08Tolerated0.18780.30261-1-3.158.04
c.3188G>C
G1063A
2D
AIThe SynGAP1 missense variant G1063A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975134Disordered0.945784Binding0.3940.9130.875-5.373Likely Benign0.079Likely BenignLikely Benign0.045Likely Benign0.33Neutral0.000Benign0.002Benign4.30Benign0.12Tolerated0.33480.4957102.214.03
c.3188G>T
G1063V
2D
AIThe SynGAP1 missense variant G1063V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority of the high‑accuracy tools) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from multiple prediction algorithms and high‑accuracy tools indicates that G1063V is most likely benign, with no ClinVar status to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975134Disordered0.945784Binding0.3940.9130.875-6.228Likely Benign0.083Likely BenignLikely Benign0.045Likely Benign-0.82Neutral0.004Benign0.002Benign4.29Benign0.03Affected0.14340.3707-1-34.642.08
c.3133G>A
A1045T
2D
AIThe SynGAP1 missense variant A1045T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly supports a benign classification, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975609Disordered0.948874Binding0.3520.8820.750-4.531Likely Benign0.074Likely BenignLikely Benign0.059Likely Benign0.03Neutral0.004Benign0.010Benign2.68Benign0.52Tolerated0.18570.668210-2.530.03
c.3133G>C
A1045P
2D
AIThe SynGAP1 missense variant A1045P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also predicts Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975609Disordered0.948874Binding0.3520.8820.750-2.260Likely Benign0.078Likely BenignLikely Benign0.099Likely Benign1.09Neutral0.586Possibly Damaging0.223Benign2.64Benign0.24Tolerated0.21300.53321-1-3.426.04
c.3133G>T
A1045S
2D
AIThe SynGAP1 missense variant A1045S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975609Disordered0.948874Binding0.3520.8820.750-3.724Likely Benign0.073Likely BenignLikely Benign0.055Likely Benign-0.11Neutral0.011Benign0.010Benign2.66Benign0.46Tolerated0.26480.549311-2.616.00
c.3134C>A
A1045D
2D
AIThe SynGAP1 missense variant A1045D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that reach consensus all indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all score the variant as benign. AlphaMissense‑Optimized also predicts a benign outcome, whereas AlphaMissense‑Default remains uncertain. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as “Likely Benign.” No tools predict pathogenicity. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the collective predictions strongly suggest that A1045D is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975609Disordered0.948874Binding0.3520.8820.750-5.734Likely Benign0.418AmbiguousLikely Benign0.066Likely Benign-1.00Neutral0.411Benign0.172Benign2.64Benign0.16Tolerated0.19540.21020-2-5.344.01
c.3134C>G
A1045G
2D
AIThe SynGAP1 missense variant A1045G is reported in ClinVar as Benign (ClinVar ID 416778.0) and is present in the gnomAD database (gnomAD ID 6‑33443686‑C‑G). Prediction tools that assess pathogenicity all converge on a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign. No tool in the dataset predicts pathogenicity. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available. Overall, the variant is most likely benign, and this prediction aligns with its ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975609Disordered0.948874Binding0.3520.8820.750Benign/Likely benign 76-33443686-C-G14078.72e-4-3.246Likely Benign0.075Likely BenignLikely Benign0.024Likely Benign-1.21Neutral0.224Benign0.066Benign2.64Benign0.33Tolerated3.7750.22460.479810-2.2-14.0310.1016/j.ajhg.2020.11.011
c.3134C>T
A1045V
2D
AIThe SynGAP1 missense variant A1045V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975609Disordered0.948874Binding0.3520.8820.750-4.229Likely Benign0.076Likely BenignLikely Benign0.035Likely Benign-0.35Neutral0.011Benign0.017Benign3.06Benign1.00Tolerated0.14870.5474002.428.05
c.2896C>A
H966N
2D
AIThe SynGAP1 missense variant H966N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while ESM1b is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates that H966N is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.750-7.579In-Between0.085Likely BenignLikely Benign0.094Likely Benign-0.84Neutral0.748Possibly Damaging0.232Benign4.06Benign0.89Tolerated0.21530.378821-0.3-23.04
c.2896C>G
H966D
2D
AIThe SynGAP1 missense variant H966D is listed in gnomAD (ID 6‑33443448‑C‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all classify the change as benign or likely benign. Only two tools predict a damaging outcome—polyPhen‑2 HumDiv and ESM1b—which are outliers relative to the consensus. High‑accuracy assessments confirm the benign trend: AlphaMissense‑Optimized reports a benign effect, and the SGM‑Consensus also indicates a likely benign status. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of predictions support a benign impact, and this is consistent with the absence of a pathogenic ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.7506-33443448-C-G16.20e-7-8.426Likely Pathogenic0.201Likely BenignLikely Benign0.182Likely Benign-1.09Neutral0.494Possibly Damaging0.170Benign4.05Benign0.93Tolerated4.3220.25040.3066-11-0.3-22.05
c.2896C>T
H966Y
2D
AIThe SynGAP1 missense variant H966Y is catalogued in gnomAD (6‑33443448‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) all classify the change as benign or likely benign. Only polyPhen‑2 HumDiv reports a pathogenic prediction, representing the sole discordant signal. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates likely benign. No Foldetta stability data are available, so folding‑stability evidence is inconclusive. Overall, the preponderance of predictions supports a benign classification for H966Y, and this conclusion is not contradicted by any ClinVar status (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.7506-33443448-C-T-6.847Likely Benign0.126Likely BenignLikely Benign0.106Likely Benign-1.27Neutral0.878Possibly Damaging0.232Benign4.01Benign0.23Tolerated4.3220.14650.4506201.926.03
c.2897A>C
H966P
2D
AIThe SynGAP1 missense variant H966P is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.750-5.831Likely Benign0.064Likely BenignLikely Benign0.279Likely Benign-0.27Neutral0.001Benign0.001Benign4.01Benign0.72Tolerated0.21680.43010-21.6-40.02
c.2897A>G
H966R
2D
AIThe SynGAP1 missense variant H966R is reported in gnomAD (ID 6‑33443449‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv flags it as pathogenic, creating a single discordant call. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods indicates that H966R is most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.7506-33443449-A-G-5.474Likely Benign0.157Likely BenignLikely Benign0.172Likely Benign-0.71Neutral0.494Possibly Damaging0.170Benign4.06Benign0.69Tolerated4.3220.21980.341002-1.319.05
c.2897A>T
H966L
2D
AIThe SynGAP1 missense variant H966L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. No pathogenic predictions are present among the evaluated algorithms. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) reports likely benign. Foldetta results are not available for this variant. Based on the collective evidence, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.750-6.119Likely Benign0.095Likely BenignLikely Benign0.183Likely Benign-1.74Neutral0.174Benign0.062Benign4.05Benign0.35Tolerated0.15140.5316-2-37.0-23.98
c.2898C>A
H966Q
2D
AIThe SynGAP1 missense variant H966Q is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that H966Q is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.750-5.662Likely Benign0.100Likely BenignLikely Benign0.113Likely Benign-0.66Neutral0.748Possibly Damaging0.232Benign4.06Benign0.45Tolerated0.20580.391430-0.3-9.01
c.2898C>G
H966Q
2D
AIThe SynGAP1 missense variant H966Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.974672Binding0.3780.8790.750-5.662Likely Benign0.100Likely BenignLikely Benign0.113Likely Benign-0.66Neutral0.748Possibly Damaging0.232Benign4.06Benign0.45Tolerated0.20580.391430-0.3-9.01
c.3184G>A
G1062R
2D
AIThe SynGAP1 missense variant G1062R is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443736‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, polyPhen‑2 HumVar, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, while Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.936972Binding0.3680.9170.875Conflicting 26-33443736-G-A74.35e-6-6.933Likely Benign0.353AmbiguousLikely Benign0.403Likely Benign-0.34Neutral0.797Possibly Damaging0.139Benign4.10Benign0.01Affected4.3220.10130.4342-3-2-4.199.14
c.3184G>C
G1062R
2D
AIThe SynGAP1 missense variant G1062R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicating a likely benign outcome, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.936972Binding0.3680.9170.875-6.933Likely Benign0.353AmbiguousLikely Benign0.413Likely Benign-0.34Neutral0.797Possibly Damaging0.139Benign4.10Benign0.01Affected4.3220.10130.4342-3-2-4.199.14
c.3184G>T
G1062W
2D
AIThe SynGAP1 missense variant G1062W is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which labels the variant as “Likely Benign.” Pathogenic predictions come from polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b, all of which classify the change as damaging. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.936972Binding0.3680.9170.875-9.667Likely Pathogenic0.315Likely BenignLikely Benign0.401Likely Benign-1.38Neutral0.993Probably Damaging0.890Possibly Damaging4.09Benign0.00Affected0.09080.4246-7-2-0.5129.16
c.3185G>A
G1062E
2D
AIThe SynGAP1 missense variant G1062E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.936972Binding0.3680.9170.875-8.185Likely Pathogenic0.272Likely BenignLikely Benign0.383Likely Benign-1.02Neutral0.126Benign0.041Benign4.10Benign0.01Affected0.14900.40690-2-3.172.06
c.3185G>C
G1062A
2D
AIThe SynGAP1 missense variant G1062A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is benign, and this conclusion does not contradict any ClinVar annotation (none present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.936972Binding0.3680.9170.875-6.124Likely Benign0.079Likely BenignLikely Benign0.350Likely Benign0.20Neutral0.059Benign0.028Benign4.20Benign0.51Tolerated0.33050.5144102.214.03
c.3185G>T
G1062V
2D
AIThe SynGAP1 missense variant G1062V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.976962Disordered0.936972Binding0.3680.9170.875-6.598Likely Benign0.103Likely BenignLikely Benign0.377Likely Benign-0.78Neutral0.259Benign0.066Benign4.12Benign0.01Affected0.14410.3694-1-34.642.08
c.2830G>A
G944S
2D
AIThe SynGAP1 missense variant G944S is listed in ClinVar as a benign alteration (ClinVar ID 833552.0) and is present in the gnomAD database (gnomAD ID 6‑33443382‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available for this variant. Overall, the majority of computational evidence supports a benign classification, which aligns with the ClinVar status and does not contradict it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.852408Binding0.3600.9230.750Benign 16-33443382-G-A138.05e-6-5.303Likely Benign0.082Likely BenignLikely Benign0.223Likely Benign-0.75Neutral0.007Benign0.004Benign3.77Benign0.00Affected4.3240.24710.550210-0.430.03
c.2830G>C
G944R
2D
AIThe SynGAP1 missense variant G944R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for G944R, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.852408Binding0.3600.9230.750-6.577Likely Benign0.359AmbiguousLikely Benign0.459Likely Benign-1.82Neutral0.639Possibly Damaging0.299Benign3.73Benign0.00Affected0.10300.4733-3-2-4.199.14
c.2830G>T
G944C
2D
AIThe SynGAP1 missense variant G944C is listed in ClinVar with no submitted interpretation and is present in gnomAD (variant ID 6‑33443382‑G‑T). Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; pathogenic predictions come from polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (majority vote of the four contributing tools) also indicates Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict the ClinVar status, which remains unclassified.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.852408Binding0.3600.9230.7506-33443382-G-T16.20e-7-9.121Likely Pathogenic0.093Likely BenignLikely Benign0.426Likely Benign-1.79Neutral0.975Probably Damaging0.848Possibly Damaging3.70Benign0.00Affected4.3240.13990.4439-3-32.946.09
c.2831G>A
G944D
2D
AIThe SynGAP1 missense variant G944D is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools largely support a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the majority‑vote SGM‑Consensus also indicates a likely benign outcome. Only SIFT predicts a pathogenic effect, and ESM1b remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports a likely benign classification. Foldetta stability analysis is not available for this residue. Overall, the preponderance of evidence points to a benign impact, and this assessment does not conflict with the absence of a ClinVar claim.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.852408Binding0.3600.9230.750-7.684In-Between0.296Likely BenignLikely Benign0.421Likely Benign-1.42Neutral0.224Benign0.131Benign3.70Benign0.00Affected0.18330.28261-1-3.158.04
c.2831G>C
G944A
2D
AIThe SynGAP1 missense variant G944A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.852408Binding0.3600.9230.750-6.397Likely Benign0.089Likely BenignLikely Benign0.314Likely Benign-0.61Neutral0.059Benign0.042Benign3.81Benign0.00Affected0.33520.4957102.214.03
c.2831G>T
G944V
2D
AIThe SynGAP1 missense variant G944V is catalogued in gnomAD (ID 6‑33443383‑G‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all classify the substitution as benign or likely benign. Only SIFT predicts a pathogenic outcome, while ESM1b remains uncertain. High‑accuracy assessments confirm the benign consensus: AlphaMissense‑Optimized reports a benign effect, and the SGM‑Consensus likewise indicates a likely benign status. No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the collective evidence points to a benign variant, and this conclusion is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign, and this assessment does not contradict its ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.852408Binding0.3600.9230.7506-33443383-G-T16.20e-7-7.536In-Between0.090Likely BenignLikely Benign0.446Likely Benign-1.41Neutral0.126Benign0.096Benign3.70Benign0.00Affected4.3240.14550.3507-3-14.642.08
c.3142G>A
G1048R
2D
AIThe SynGAP1 missense variant G1048R is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Functional prediction tools show a split: pathogenic calls come from REVEL, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar, whereas benign calls are made by PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus, derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a benign majority, and AlphaMissense‑Optimized itself predicts benign. The SGM‑Consensus, which aggregates these four predictors, reports a likely benign classification. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the absence of a ClinVar assertion; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.923876Binding0.3460.9160.750-4.305Likely Benign0.435AmbiguousLikely Benign0.503Likely Pathogenic-0.54Neutral0.919Possibly Damaging0.728Possibly Damaging2.54Benign0.10Tolerated3.7750.09560.4332-2-3-4.199.14
c.3142G>C
G1048R
2D
AIThe SynGAP1 missense variant G1048R is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Prediction tools that agree on a benign effect include PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are REVEL, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. The high‑accuracy AlphaMissense‑Optimized score is benign, and the SGM‑Consensus also indicates a likely benign outcome; the Foldetta protein‑folding stability assessment is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.923876Binding0.3460.9160.750Uncertain 1-4.305Likely Benign0.435AmbiguousLikely Benign0.503Likely Pathogenic-0.54Neutral0.919Possibly Damaging0.728Possibly Damaging2.54Benign0.10Tolerated3.7750.09560.4332-2-3-4.199.14
c.3142G>T
G1048W
2D
AIThe SynGAP1 missense variant G1048W is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.923876Binding0.3460.9160.750-8.803Likely Pathogenic0.340Likely BenignLikely Benign0.498Likely Benign-1.52Neutral0.996Probably Damaging0.961Probably Damaging2.54Benign0.02Affected0.08520.4046-7-2-0.5129.16
c.3143G>A
G1048E
2D
AIThe SynGAP1 missense variant G1048E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only REVEL predicts a pathogenic outcome, while ESM1b is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect. The variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.923876Binding0.3460.9160.750-7.028In-Between0.331Likely BenignLikely Benign0.529Likely Pathogenic-0.62Neutral0.018Benign0.030Benign2.54Benign0.10Tolerated0.14440.40630-2-3.172.06
c.3143G>C
G1048A
2D
AISynGAP1 missense variant G1048A is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only polyPhen‑2 HumDiv predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” status. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that G1048A is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.923876Binding0.3460.9160.750-4.821Likely Benign0.079Likely BenignLikely Benign0.456Likely Benign-0.14Neutral0.573Possibly Damaging0.358Benign2.57Benign0.64Tolerated0.33010.5138102.214.03
c.3143G>T
G1048V
2D
AIThe SynGAP1 missense variant G1048V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are REVEL, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. Thus, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.923876Binding0.3460.9160.750-6.108Likely Benign0.079Likely BenignLikely Benign0.520Likely Pathogenic-0.59Neutral0.958Probably Damaging0.787Possibly Damaging2.54Benign0.11Tolerated0.13120.3688-1-34.642.08
c.2902G>A
G968S
2D
AIThe SynGAP1 missense variant G968S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.961360Binding0.3270.8960.750-4.484Likely Benign0.070Likely BenignLikely Benign0.124Likely Benign-0.35Neutral0.058Benign0.023Benign4.22Benign0.37Tolerated0.24820.569910-0.430.03
c.2902G>C
G968R
2D
AIThe SynGAP1 missense variant G968R is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the evidence strongly supports a benign classification, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.961360Binding0.3270.8960.750-4.492Likely Benign0.332Likely BenignLikely Benign0.140Likely Benign-0.63Neutral0.005Benign0.012Benign4.19Benign0.08Tolerated0.09720.5017-3-2-4.199.14
c.2902G>T
G968C
2D
AIThe SynGAP1 missense variant G968C is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.961360Binding0.3270.8960.750-8.441Likely Pathogenic0.117Likely BenignLikely Benign0.170Likely Benign-0.99Neutral0.992Probably Damaging0.820Possibly Damaging4.12Benign0.07Tolerated0.12940.4768-3-32.946.09
c.2903G>A
G968D
2D
AIThe SynGAP1 missense variant G968D is catalogued in gnomAD (ID 6‑33443455‑G‑A) but has no ClinVar entry. Across a broad panel of in‑silico predictors, every tool reports a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity, so the pathogenic‑prediction group is empty. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available for this variant. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.961360Binding0.3270.8960.7506-33443455-G-A16.20e-7-5.134Likely Benign0.179Likely BenignLikely Benign0.157Likely Benign-0.48Neutral0.440Benign0.198Benign4.19Benign0.21Tolerated4.3220.19650.3243-11-3.158.04
c.2903G>C
G968A
2D
AIThe SynGAP1 missense variant G968A is predicted to be benign by all available in‑silico tools. Consensus predictors (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized) and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all classify the change as benign. No tools predict pathogenicity, so the pathogenic group is empty. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized reports benign, and the SGM‑Consensus indicates “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Based on the unanimous benign predictions and the absence of ClinVar evidence, the variant is most likely benign and does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.961360Binding0.3270.8960.750-4.721Likely Benign0.070Likely BenignLikely Benign0.076Likely Benign-0.33Neutral0.245Benign0.140Benign4.24Benign0.68Tolerated0.34010.5154102.214.03
c.2903G>T
G968V
2D
AIThe SynGAP1 missense variant G968V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. The predictions do not contradict ClinVar status, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.961360Binding0.3270.8960.750-6.152Likely Benign0.093Likely BenignLikely Benign0.239Likely Benign-1.08Neutral0.918Possibly Damaging0.525Possibly Damaging4.19Benign0.11Tolerated0.12520.4036-1-34.642.08
c.3145C>A
P1049T
2D
AIThe SynGAP1 missense variant P1049T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and SIFT—suggest a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta results are unavailable, so no additional stability evidence is present. Overall, the consensus of available predictions indicates that P1049T is most likely benign, and this assessment does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.917915Binding0.4280.9200.750-5.100Likely Benign0.056Likely BenignLikely Benign0.088Likely Benign-1.18Neutral0.519Possibly Damaging0.222Benign2.74Benign0.02Affected0.17910.55140-10.93.99
c.3145C>G
P1049A
2D
AIThe SynGAP1 missense variant P1049A is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.917915Binding0.4280.9200.750-3.870Likely Benign0.049Likely BenignLikely Benign0.055Likely Benign-1.43Neutral0.180Benign0.171Benign2.81Benign0.06Tolerated0.33060.48971-13.4-26.04
c.3145C>T
P1049S
2D
AIThe SynGAP1 missense variant P1049S is reported in gnomAD (variant ID 6‑33443697‑C‑T) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the majority of predictions, including the high‑accuracy tools, indicate that P1049S is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.917915Binding0.4280.9200.7506-33443697-C-T21.24e-6-2.351Likely Benign0.053Likely BenignLikely Benign0.071Likely Benign-1.53Neutral0.519Possibly Damaging0.303Benign2.76Benign0.04Affected3.7750.31440.5083-110.8-10.04
c.3146C>A
P1049H
2D
AIThe SynGAP1 missense variant P1049H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.917915Binding0.4280.9200.750-5.427Likely Benign0.115Likely BenignLikely Benign0.066Likely Benign-2.06Neutral0.978Probably Damaging0.750Possibly Damaging2.76Benign0.01Affected0.18000.50700-2-1.640.02
c.3146C>G
P1049R
2D
AIThe SynGAP1 missense variant P1049R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized returns Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability prediction is available for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.917915Binding0.4280.9200.750-5.144Likely Benign0.145Likely BenignLikely Benign0.067Likely Benign-1.90Neutral0.791Possibly Damaging0.500Possibly Damaging2.74Benign0.03Affected0.13760.37690-2-2.959.07
c.3146C>T
P1049L
2D
AIThe SynGAP1 missense variant P1049L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.917915Binding0.4280.9200.750-4.819Likely Benign0.099Likely BenignLikely Benign0.097Likely Benign-2.37Neutral0.001Benign0.002Benign2.71Benign0.02Affected0.22670.5838-3-35.416.04
c.3190C>A
Q1064K
2D
AIThe SynGAP1 missense variant Q1064K is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective predictions strongly support a benign classification, and this conclusion is consistent with the lack of any ClinVar pathogenic annotation, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875-3.592Likely Benign0.234Likely BenignLikely Benign0.088Likely Benign-0.32Neutral0.224Benign0.120Benign4.23Benign0.24Tolerated0.27580.419211-0.40.04
c.3190C>G
Q1064E
2D
AIThe SynGAP1 missense variant Q1064E is not reported in ClinVar and is absent from gnomAD. All available in‑silico predictors classify it as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are not available. Based on the unanimous benign predictions and lack of ClinVar evidence, the variant is most likely benign and does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875-4.277Likely Benign0.184Likely BenignLikely Benign0.075Likely Benign-0.48Neutral0.203Benign0.077Benign4.22Benign0.32Tolerated0.22590.2843220.00.98
c.3191A>C
Q1064P
2D
AIThe SynGAP1 missense variant Q1064P is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875-2.032Likely Benign0.058Likely BenignLikely Benign0.270Likely Benign0.93Neutral0.001Benign0.001Benign4.23Benign0.20Tolerated0.28190.47660-11.9-31.01
c.3191A>G
Q1064R
2D
AIThe SynGAP1 missense variant Q1064R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and there is no conflict with ClinVar status because the variant is not yet classified there. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875-2.981Likely Benign0.202Likely BenignLikely Benign0.143Likely Benign-0.28Neutral0.586Possibly Damaging0.159Benign4.19Benign0.16Tolerated0.22570.365411-1.028.06
c.3191A>T
Q1064L
2D
AIThe SynGAP1 missense variant Q1064L is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, is not available for this variant. Overall, the consensus of all available predictions strongly supports a benign classification, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875-3.492Likely Benign0.099Likely BenignLikely Benign0.133Likely Benign-1.16Neutral0.224Benign0.091Benign4.20Benign0.13Tolerated0.18170.5485-2-27.3-14.97
c.3192G>C
Q1064H
2D
AIThe SynGAP1 missense variant Q1064H is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. The Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence—including high‑accuracy tools—points to a benign effect, and this conclusion does not contradict the current ClinVar “Uncertain” status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875Uncertain 1-4.576Likely Benign0.162Likely BenignLikely Benign0.063Likely Benign-0.66Neutral0.938Possibly Damaging0.596Possibly Damaging4.15Benign0.05Affected0.24670.4243300.39.01
c.3192G>T
Q1064H
2D
AIThe SynGAP1 missense variant Q1064H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for Q1064H, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978316Disordered0.953106Binding0.3780.9140.875-4.576Likely Benign0.162Likely BenignLikely Benign0.063Likely Benign-0.66Neutral0.938Possibly Damaging0.596Possibly Damaging4.15Benign0.05Affected0.24670.4243300.39.01
c.3127A>G
R1043G
2D
AIThe SynGAP1 missense variant R1043G is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.954069Binding0.2990.8530.625-2.168Likely Benign0.201Likely BenignLikely Benign0.383Likely Benign-3.17Deleterious0.130Benign0.049Benign5.94Benign0.00Affected0.31790.3697-3-24.1-99.14
c.3127A>T
R1043W
2D
AIThe SynGAP1 missense variant R1043W is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields a benign prediction; Foldetta results are unavailable. Overall, the majority of high‑confidence tools predict a benign impact, and there is no ClinVar annotation to contradict this assessment. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.978672Disordered0.954069Binding0.2990.8530.625-6.382Likely Benign0.523AmbiguousLikely Benign0.444Likely Benign-3.43Deleterious0.971Probably Damaging0.729Possibly Damaging5.38Benign0.00Affected0.14030.36962-33.630.03
c.3128G>A
R1043K
2D
AIThe SynGAP1 missense variant R1043K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar or gnomAD entries—there is no contradiction with existing database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.954069Binding0.2990.8530.625-4.038Likely Benign0.162Likely BenignLikely Benign0.376Likely Benign-1.41Neutral0.069Benign0.033Benign5.39Benign0.00Affected0.51410.4070Weaken320.6-28.01
c.3128G>C
R1043T
2D
AIThe SynGAP1 missense variant R1043T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from SIFT. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.954069Binding0.2990.8530.625-3.928Likely Benign0.298Likely BenignLikely Benign0.463Likely Benign-1.77Neutral0.001Benign0.003Benign5.39Benign0.00Affected0.19750.5513-1-13.8-55.08
c.3128G>T
R1043M
2D
AIThe SynGAP1 missense variant R1043M is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Consensus predictions from multiple in‑silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict benign, while polyPhen‑2 HumDiv and SIFT predict pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus also indicates Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for R1043M, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.954069Binding0.2990.8530.625-4.800Likely Benign0.510AmbiguousLikely Benign0.471Likely Benign-1.98Neutral0.744Possibly Damaging0.229Benign5.38Benign0.00Affected0.19820.44680-16.4-24.99
c.3129G>C
R1043S
2D
AIThe SynGAP1 missense variant R1043S is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools cluster into two groups: benign predictions include PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions come from REVEL and SIFT. AlphaMissense‑Default is uncertain, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized scores benign, SGM‑Consensus is likely benign, and Foldetta results are unavailable. Taken together, the majority of evidence points to a benign impact for R1043S. This conclusion is consistent with the absence of a ClinVar assertion, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.954069Binding0.2990.8530.625-3.223Likely Benign0.457AmbiguousLikely Benign0.509Likely Pathogenic-2.10Neutral0.036Benign0.018Benign5.42Benign0.00Affected3.7750.27270.4628-103.7-69.11
c.3129G>T
R1043S
2D
AIThe SynGAP1 missense variant R1043S is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443681‑G‑T). Prediction tools that agree on a benign effect include PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are REVEL and SIFT. AlphaMissense‑Default remains uncertain, and no Foldetta stability result is available. High‑accuracy assessments: AlphaMissense‑Optimized classifies the variant as benign; the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome; Foldetta data are missing, so it does not contribute to the evaluation. Based on the collective predictions, the variant is most likely benign, which is consistent with its ClinVar “Uncertain” classification and does not contradict the available evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.954069Binding0.2990.8530.625Uncertain 16-33443681-G-T21.24e-6-3.223Likely Benign0.457AmbiguousLikely Benign0.509Likely Pathogenic-2.10Neutral0.036Benign0.018Benign5.42Benign0.00Affected3.7750.27270.4628-103.7-69.11
c.3181G>A
G1061S
2D
AIThe SynGAP1 missense variant G1061S is listed in ClinVar (ID 3571724.0) with an uncertain significance designation and is not reported in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only SIFT indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta stability analysis is unavailable. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods supports a benign classification for G1061S, which is consistent with its ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.926729Binding0.3940.9230.875Uncertain 1-4.891Likely Benign0.079Likely BenignLikely Benign0.283Likely Benign-0.68Neutral0.004Benign0.004Benign4.00Benign0.00Affected0.24040.530010-0.430.03
c.3181G>C
G1061R
2D
AIThe SynGAP1 missense variant G1061R is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while ESM1b and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because it contains two benign and two uncertain calls, and Foldetta results are unavailable. Overall, the balance of evidence favors a benign classification. This conclusion does not contradict ClinVar status, as the variant has not been reported there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.978672Disordered0.926729Binding0.3940.9230.875-7.721In-Between0.343AmbiguousLikely Benign0.315Likely Benign-0.17Neutral0.411Benign0.132Benign3.99Benign0.00Affected0.10370.4332-3-2-4.199.14
c.3181G>T
G1061C
2D
AIThe SynGAP1 missense variant G1061C is listed in ClinVar (ID 536997.0) with an “Uncertain” clinical significance and is present in gnomAD (variant ID 6‑33443733‑G‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign; Foldetta results are not available. Overall, the majority of evidence (six benign vs. four pathogenic predictions) and the two high‑accuracy tools support a benign classification. This conclusion does not contradict the ClinVar status, which remains uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.926729Binding0.3940.9230.875Conflicting 26-33443733-G-T63.73e-6-9.511Likely Pathogenic0.119Likely BenignLikely Benign0.409Likely Benign-1.46Neutral0.938Possibly Damaging0.665Possibly Damaging3.97Benign0.00Affected4.3220.12830.4227-3-32.946.09
c.3182G>A
G1061D
2D
AIThe SynGAP1 missense variant G1061D is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign prediction (2 benign vs. 1 pathogenic, 1 uncertain). Foldetta results are unavailable. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.978672Disordered0.926729Binding0.3940.9230.875-9.481Likely Pathogenic0.346AmbiguousLikely Benign0.375Likely Benign-1.32Neutral0.224Benign0.120Benign4.01Benign0.00Affected0.16710.20241-1-3.158.04
c.3182G>C
G1061A
2D
AIThe SynGAP1 missense variant G1061A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.926729Binding0.3940.9230.875-6.328Likely Benign0.082Likely BenignLikely Benign0.244Likely Benign-0.34Neutral0.004Benign0.002Benign4.01Benign0.00Affected0.32890.5133102.214.03
c.3182G>T
G1061V
2D
AIThe SynGAP1 missense variant G1061V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign. Foldetta results are unavailable. Overall, the majority of evidence indicates that G1061V is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.926729Binding0.3940.9230.875-6.709Likely Benign0.106Likely BenignLikely Benign0.307Likely Benign-1.41Neutral0.224Benign0.066Benign3.98Benign0.00Affected0.14310.3684-1-34.642.08
c.3178G>A
G1060S
2D
AIThe SynGAP1 missense variant G1060S is listed in ClinVar with an uncertain significance (ClinVar ID 1512003.0) and is present in gnomAD (variant ID 6‑33443730‑G‑A). All evaluated in‑silico predictors classify the change as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this benign view: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the computational evidence overwhelmingly supports a benign effect, which is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979242Disordered0.913048Binding0.4070.9280.875Uncertain 16-33443730-G-A-4.759Likely Benign0.082Likely BenignLikely Benign0.376Likely Benign-0.08Neutral0.271Benign0.054Benign2.69Benign0.49Tolerated4.3220.24680.531110-0.430.03
c.3178G>C
G1060R
2D
AIThe SynGAP1 missense variant G1060R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for G1060R, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979242Disordered0.913048Binding0.4070.9280.875-8.225Likely Pathogenic0.323Likely BenignLikely Benign0.362Likely Benign-0.29Neutral0.971Probably Damaging0.580Possibly Damaging2.63Benign0.17Tolerated0.10380.4342-3-2-4.199.14
c.3178G>T
G1060C
2D
AIThe SynGAP1 missense variant G1060C is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for G1060C, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979242Disordered0.913048Binding0.4070.9280.875-9.630Likely Pathogenic0.116Likely BenignLikely Benign0.363Likely Benign-0.60Neutral0.999Probably Damaging0.917Probably Damaging2.63Benign0.12Tolerated0.13400.4227-3-32.946.09
c.3179G>A
G1060D
2D
AIThe SynGAP1 missense variant G1060D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also leans benign (2 benign vs 1 pathogenic). Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.979242Disordered0.913048Binding0.4070.9280.875-9.824Likely Pathogenic0.342AmbiguousLikely Benign0.391Likely Benign-0.58Neutral0.905Possibly Damaging0.538Possibly Damaging2.63Benign0.20Tolerated0.17030.20351-1-3.158.04
c.3179G>C
G1060A
2D
AIThe SynGAP1 missense variant G1060A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic outcome, creating a single discordant signal. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979242Disordered0.913048Binding0.4070.9280.875-6.539Likely Benign0.082Likely BenignLikely Benign0.341Likely Benign0.30Neutral0.664Possibly Damaging0.283Benign2.69Benign0.98Tolerated0.33350.4944102.214.03
c.3179G>T
G1060V
2D
AIThe SynGAP1 missense variant G1060V is listed in ClinVar as benign (ClinVar ID 1345112.0) and is observed in gnomAD (6‑33443731‑G‑T). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Two tools, polyPhen‑2 HumDiv and HumVar, predict a pathogenic effect. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as likely benign, and AlphaMissense‑Optimized also reports a benign outcome. No Foldetta stability assessment is available for this variant. Overall, the majority of evidence points to a benign impact, aligning with the ClinVar designation and not contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979242Disordered0.913048Binding0.4070.9280.875Benign 16-33443731-G-T16.22e-7-6.966Likely Benign0.103Likely BenignLikely Benign0.369Likely Benign-0.73Neutral0.986Probably Damaging0.728Possibly Damaging2.63Benign0.33Tolerated4.3220.14530.3494-1-34.642.08
c.2380C>A
P794T
2D
AIThe SynGAP1 missense variant P794T is catalogued in gnomAD (ID 6‑33442932‑C‑A) but has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool in the dataset predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields a benign prediction. The Foldetta stability analysis is not available for this variant. Overall, the consensus of all available predictions is benign, and this is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.979741Disordered0.408951Uncertain0.5500.8980.8756-33442932-C-A16.20e-7-4.838Likely Benign0.060Likely BenignLikely Benign0.046Likely Benign-0.34Neutral0.245Benign0.138Benign4.25Benign0.66Tolerated4.0730.17390.6207-100.93.99
c.2380C>G
P794A
2D
AIThe SynGAP1 missense variant P794A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). All evaluated in‑silico predictors classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta results are unavailable, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.979741Disordered0.408951Uncertain0.5500.8980.875-3.766Likely Benign0.056Likely BenignLikely Benign0.038Likely Benign-0.63Neutral0.124Benign0.089Benign4.27Benign0.09Tolerated0.36920.52091-13.4-26.04
c.2380C>T
P794S
2D
AIThe SynGAP1 missense variant P794S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are not available, so they do not influence the assessment. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.979741Disordered0.408951Uncertain0.5500.8980.875-5.086Likely Benign0.079Likely BenignLikely Benign0.041Likely Benign-0.21Neutral0.025Benign0.010Benign4.29Benign0.13Tolerated0.36660.56041-10.8-10.04
c.2381C>A
P794Q
2D
AIThe SynGAP1 missense variant P794Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect for P794Q, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.979741Disordered0.408951Uncertain0.5500.8980.875-4.641Likely Benign0.101Likely BenignLikely Benign0.058Likely Benign-0.31Neutral0.918Possibly Damaging0.601Possibly Damaging4.24Benign0.02Affected0.15810.49710-1-1.931.01
c.2381C>G
P794R
2D
AIThe SynGAP1 missense variant P794R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability result is available. Overall, the majority of evidence points to a benign effect for P794R, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.979741Disordered0.408951Uncertain0.5500.8980.875-5.136Likely Benign0.260Likely BenignLikely Benign0.083Likely Benign-0.73Neutral0.918Possibly Damaging0.522Possibly Damaging4.25Benign0.02Affected0.14670.36620-2-2.959.07
c.2381C>T
P794L
2D
AIThe SynGAP1 missense variant P794L is listed in ClinVar as Benign (ClinVar ID 859213.0) and is present in the gnomAD database (gnomAD ID 6‑33442933‑C‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. The SGM‑Consensus, which is a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as benign, while Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Overall, the consensus of available predictions indicates that P794L is most likely benign, and this conclusion is consistent with its ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.979741Disordered0.408951Uncertain0.5500.8980.875Benign/Likely benign 26-33442933-C-T734.52e-5-3.808Likely Benign0.079Likely BenignLikely Benign0.075Likely Benign-0.80Neutral0.761Possibly Damaging0.321Benign4.24Benign0.03Affected4.0730.24170.6733-3-35.416.04
c.3130C>A
P1044T
2D
AIThe SynGAP1 missense variant P1044T is catalogued in gnomAD (ID 6‑33443682‑C‑A) but has no ClinVar entry. Across a broad panel of in silico predictors, every tool reports a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool in the set predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized returns a benign prediction, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, was not available for this variant. Overall, the computational evidence overwhelmingly supports a benign effect, and this is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.952126Binding0.3310.8550.7506-33443682-C-A16.20e-7-4.605Likely Benign0.075Likely BenignLikely Benign0.372Likely Benign-1.02Neutral0.126Benign0.096Benign5.53Benign0.17Tolerated3.7750.16810.6860-100.93.99
c.3130C>G
P1044A
2D
AIThe SynGAP1 missense variant P1044A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence strongly supports a benign classification, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.952126Binding0.3310.8550.750-3.957Likely Benign0.059Likely BenignLikely Benign0.359Likely Benign-1.07Neutral0.059Benign0.061Benign5.50Benign0.18Tolerated0.31940.58501-13.4-26.04
c.3130C>T
P1044S
2D
AIThe SynGAP1 missense variant P1044S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.952126Binding0.3310.8550.750-4.114Likely Benign0.078Likely BenignLikely Benign0.311Likely Benign-0.79Neutral0.011Benign0.015Benign5.51Benign0.14Tolerated0.31940.60811-10.8-10.04
c.3131C>A
P1044Q
2D
AIThe SynGAP1 missense variant P1044Q is not reported in ClinVar and is absent from gnomAD. All evaluated in‑silico predictors—REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods likewise support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.952126Binding0.3310.8550.750-4.439Likely Benign0.091Likely BenignLikely Benign0.338Likely Benign0.51Neutral0.004Benign0.015Benign5.43Benign0.45Tolerated0.15440.55910-1-1.931.01
c.3131C>G
P1044R
2D
AIThe SynGAP1 missense variant P1044R is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign classification, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.952126Binding0.3310.8550.750-3.969Likely Benign0.242Likely BenignLikely Benign0.368Likely Benign0.79Neutral0.259Benign0.140Benign5.45Benign1.00Tolerated0.14510.42700-2-2.959.07
c.3131C>T
P1044L
2D
AIThe SynGAP1 missense variant P1044L is not represented in ClinVar (no ClinVar ID) and is absent from gnomAD. All evaluated in‑silico predictors classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool reports a pathogenic or likely pathogenic outcome. High‑accuracy assessments reinforce this benign prediction: AlphaMissense‑Optimized indicates benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.952126Binding0.3310.8550.750-4.327Likely Benign0.144Likely BenignLikely Benign0.418Likely Benign-1.64Neutral0.411Benign0.187Benign5.43Benign0.15Tolerated0.22640.6586-3-35.416.04
c.3193C>A
P1065T
2D
AIThe SynGAP1 missense variant P1065T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of predictions (six benign vs. four pathogenic) lean toward a benign classification. There is no ClinVar status to contradict this assessment, so the variant is most likely benign based on current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.959518Binding0.4240.9170.875-5.392Likely Benign0.074Likely BenignLikely Benign0.062Likely Benign-1.23Neutral0.770Possibly Damaging0.481Possibly Damaging2.04Pathogenic0.00Affected0.15770.67880-10.93.99
c.3193C>G
P1065A
2D
AIThe SynGAP1 missense variant P1065A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for P1065A, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.959518Binding0.4240.9170.875-4.043Likely Benign0.054Likely BenignLikely Benign0.050Likely Benign-1.85Neutral0.580Possibly Damaging0.184Benign2.19Pathogenic0.00Affected0.31400.57901-13.4-26.04
c.3193C>T
P1065S
2D
AIThe SynGAP1 missense variant P1065S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.959518Binding0.4240.9170.875-5.512Likely Benign0.076Likely BenignLikely Benign0.041Likely Benign-2.07Neutral0.770Possibly Damaging0.255Benign2.06Pathogenic0.00Affected0.31720.60211-10.8-10.04
c.3194C>A
P1065Q
2D
AIThe SynGAP1 missense variant P1065Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.959518Binding0.4240.9170.875-3.928Likely Benign0.074Likely BenignLikely Benign0.026Likely Benign-2.44Neutral0.102Benign0.057Benign2.00Pathogenic0.00Affected0.14870.54780-1-1.931.01
c.3194C>G
P1065R
2D
AIThe SynGAP1 missense variant P1065R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence from multiple independent predictors indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.979741Disordered0.959518Binding0.4240.9170.875-3.237Likely Benign0.228Likely BenignLikely Benign0.043Likely Benign-2.46Neutral0.102Benign0.052Benign2.00Pathogenic0.00Affected0.14390.43690-2-2.959.07
c.3194C>T
P1065L
2D
AIThe SynGAP1 missense variant P1065L is listed in ClinVar as Benign and is present in gnomAD (ID 6‑33443746‑C‑T). Functional prediction tools cluster into two groups: benign predictions come from REVEL, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized; pathogenic predictions arise from PROVEAN, polyPhen‑2 HumDiv, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—yields a tie and is therefore inconclusive. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no reported result for this variant. Overall, the balance of evidence (5 benign vs. 4 pathogenic predictions) and the high‑accuracy benign call support a benign classification, aligning with the ClinVar status and indicating no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.979741Disordered0.959518Binding0.4240.9170.875Likely Benign 16-33443746-C-T148.71e-6-5.085Likely Benign0.089Likely BenignLikely Benign0.068Likely Benign-2.94Deleterious0.950Possibly Damaging0.419Benign2.01Pathogenic0.00Affected4.3220.22860.6922-3-35.416.04
c.3172G>A
G1058S
2D
AIThe SynGAP1 missense variant G1058S is listed in ClinVar with an “Uncertain” status and is present in gnomAD (variant ID 6-33443724-G-A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Only SIFT predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is also benign. Foldetta results are unavailable. Overall, the majority of computational evidence indicates that the variant is most likely benign, and this conclusion does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.980739Disordered0.885724Binding0.4070.9290.875Conflicting 36-33443724-G-A1147.08e-5-5.178Likely Benign0.081Likely BenignLikely Benign0.108Likely Benign0.26Neutral0.001Benign0.001Benign5.38Benign0.04Affected3.7750.24880.551110-0.430.03
c.3172G>C
G1058R
2D
AIThe SynGAP1 missense variant G1058R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only two predictors—SIFT and ESM1b—suggest a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign consensus. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not conflict with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.980739Disordered0.885724Binding0.4070.9290.875-8.967Likely Pathogenic0.339Likely BenignLikely Benign0.138Likely Benign0.34Neutral0.174Benign0.140Benign5.29Benign0.00Affected0.11450.4342-3-2-4.199.14
c.3172G>T
G1058C
2D
AIThe SynGAP1 missense variant G1058C is reported in gnomAD (ID 6‑33443724‑G‑T) but has no ClinVar entry. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are polyPhen‑2 HumDiv, SIFT, and ESM1b. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of computational evidence points to a benign effect, and this is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.980739Disordered0.885724Binding0.4070.9290.8756-33443724-G-T16.21e-7-9.384Likely Pathogenic0.132Likely BenignLikely Benign0.264Likely Benign-0.19Neutral0.600Possibly Damaging0.433Benign5.19Benign0.01Affected3.7750.14560.4627-3-32.946.09
c.3173G>A
G1058D
2D
AIThe SynGAP1 missense variant G1058D is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33443725‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict ClinVar, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.980739Disordered0.885724Binding0.4070.9290.8756-33443725-G-A16.21e-7-10.344Likely Pathogenic0.391AmbiguousLikely Benign0.177Likely Benign-0.33Neutral0.077Benign0.042Benign5.20Benign0.01Affected3.7750.18890.2435-11-3.158.04
c.3173G>C
G1058A
2D
AIThe SynGAP1 missense variant G1058A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.980739Disordered0.885724Binding0.4070.9290.875-6.823Likely Benign0.082Likely BenignLikely Benign0.159Likely Benign0.21Neutral0.000Benign0.002Benign5.29Benign0.55Tolerated0.32880.5144102.214.03
c.3173G>T
G1058V
2D
AIThe SynGAP1 missense variant G1058V is reported in gnomAD (variant ID 6‑33443725‑G‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.980739Disordered0.885724Binding0.4070.9290.8756-33443725-G-T16.21e-7-6.877Likely Benign0.114Likely BenignLikely Benign0.152Likely Benign-0.12Neutral0.000Benign0.001Benign5.22Benign0.01Affected3.7750.15610.3694-3-14.642.08
c.3157A>C
S1053R
2D
AIThe SynGAP1 missense variant S1053R is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority‑vote SGM‑Consensus also reports a likely benign outcome. In contrast, the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy analyses reinforce the benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is likely benign, with no contradictory Foldetta data. Overall, the preponderance of evidence points to a benign effect for S1053R, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.875-6.421Likely Benign0.359AmbiguousLikely Benign0.225Likely Benign0.43Neutral0.969Probably Damaging0.581Possibly Damaging5.33Benign0.59Tolerated3.7750.13210.3820-10-3.769.11
c.3157A>G
S1053G
2D
AIThe SynGAP1 missense variant S1053G is not reported in ClinVar and is absent from gnomAD, indicating no documented allele frequency data. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions strongly suggests that S1053G is most likely benign, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.875-1.016Likely Benign0.050Likely BenignLikely Benign0.220Likely Benign-0.57Neutral0.001Benign0.002Benign5.32Benign0.59Tolerated0.27240.5046100.4-30.03
c.3157A>T
S1053C
2D
AIThe SynGAP1 missense variant S1053C is catalogued in gnomAD (ID 6‑33443709‑A‑T) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The ESM1b score is uncertain, providing no clear direction. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no reported result for this variant. Overall, the majority of reliable predictors classify S1053C as benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.8756-33443709-A-T-7.574In-Between0.095Likely BenignLikely Benign0.220Likely Benign-0.61Neutral0.977Probably Damaging0.777Possibly Damaging5.30Benign0.11Tolerated3.7750.16750.5895-103.316.06
c.3158G>A
S1053N
2D
AIThe SynGAP1 missense variant S1053N is reported in gnomAD (variant ID 6‑33443710‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts it as pathogenic, while the consensus score from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus also indicates a likely benign outcome. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.8756-33443710-G-A16.21e-7-6.282Likely Benign0.120Likely BenignLikely Benign0.208Likely Benign-0.54Neutral0.625Possibly Damaging0.193Benign5.30Benign0.34Tolerated3.7750.19530.460511-2.727.03
c.3158G>C
S1053T
2D
AIThe SynGAP1 missense variant S1053T is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts it as pathogenic, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the preponderance of evidence points to a benign impact for S1053T, and this conclusion is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.875-6.209Likely Benign0.076Likely BenignLikely Benign0.223Likely Benign-0.25Neutral0.625Possibly Damaging0.249Benign5.32Benign0.70Tolerated0.20550.5976110.114.03
c.3158G>T
S1053I
2D
AIThe SynGAP1 missense variant S1053I is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that S1053I is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.875-6.572Likely Benign0.177Likely BenignLikely Benign0.250Likely Benign-0.46Neutral0.925Possibly Damaging0.413Benign5.32Benign0.10Tolerated0.15360.4780-1-25.326.08
c.3159C>A
S1053R
2D
AIThe SynGAP1 missense variant S1053R is reported in gnomAD (variant ID 6‑33443711‑C‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. Overall, the majority of high‑accuracy predictors and consensus analyses indicate a benign impact. Thus, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.8756-33443711-C-A11.10e-6-6.421Likely Benign0.359AmbiguousLikely Benign0.303Likely Benign0.43Neutral0.969Probably Damaging0.581Possibly Damaging5.33Benign0.59Tolerated3.7750.13210.3820-10-3.769.11
c.3159C>G
S1053R
2D
AIThe SynGAP1 missense variant S1053R is reported in gnomAD (ID 6‑33443711‑C‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and the high‑accuracy consensus methods give a benign verdict: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports “Likely Benign.” Foldetta, a protein‑folding stability predictor combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact. The predictions do not contradict any ClinVar status, as none is currently assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.981594Disordered0.885608Binding0.3990.9440.8756-33443711-C-G-6.421Likely Benign0.359AmbiguousLikely Benign0.304Likely Benign0.43Neutral0.969Probably Damaging0.581Possibly Damaging5.33Benign0.59Tolerated3.7750.13210.3820-10-3.769.11
c.2833C>A
H945N
2D
AIThe SynGAP1 missense variant H945N is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability result is available. Overall, the majority of evidence points to a benign effect for H945N, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.750-5.709Likely Benign0.078Likely BenignLikely Benign0.266Likely Benign-0.29Neutral0.982Probably Damaging0.870Possibly Damaging5.03Benign0.05Affected0.25560.299721-0.3-23.04
c.2833C>G
H945D
2D
AIThe SynGAP1 missense variant H945D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Pathogenic predictions come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for H945D, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.750-6.572Likely Benign0.191Likely BenignLikely Benign0.396Likely Benign-0.18Neutral0.982Probably Damaging0.870Possibly Damaging5.02Benign0.04Affected0.28030.22751-1-0.3-22.05
c.2833C>T
H945Y
2D
AIThe SynGAP1 missense variant H945Y is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates Likely Benign. No Foldetta stability result is available. Overall, the majority of evidence points to a benign effect for H945Y, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.750-6.036Likely Benign0.112Likely BenignLikely Benign0.335Likely Benign-0.07Neutral0.982Probably Damaging0.903Possibly Damaging5.27Benign0.05Affected0.21020.3912021.926.03
c.2834A>C
H945P
2D
AIThe SynGAP1 missense variant H945P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Based on the preponderance of benign predictions and the lack of pathogenic evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.750-1.962Likely Benign0.055Likely BenignLikely Benign0.420Likely Benign-0.34Neutral0.012Benign0.047Benign5.04Benign0.05Affected0.27300.39070-21.6-40.02
c.2834A>G
H945R
2D
AIThe SynGAP1 missense variant H945R is reported in gnomAD (variant ID 6‑33443386‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only the two polyPhen‑2 implementations (HumDiv and HumVar) predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.7506-33443386-A-G16.20e-7-5.186Likely Benign0.118Likely BenignLikely Benign0.333Likely Benign-0.59Neutral0.982Probably Damaging0.903Possibly Damaging5.05Benign0.08Tolerated4.3240.27640.302002-1.319.05
c.2834A>T
H945L
2D
AIThe SynGAP1 missense variant H945L is reported in gnomAD (ID 6‑33443386‑A‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict the variant to be pathogenic. High‑accuracy assessments reinforce the benign view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this is consistent with the absence of a pathogenic ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.7506-33443386-A-T21.24e-6-4.741Likely Benign0.088Likely BenignLikely Benign0.399Likely Benign0.16Neutral0.948Possibly Damaging0.863Possibly Damaging5.05Benign1.00Tolerated4.3240.20850.4526-3-27.0-23.98
c.2835T>A
H945Q
2D
AIThe SynGAP1 missense variant H945Q is listed in ClinVar with an uncertain significance and is present in gnomAD (ID 6‑33443387‑T‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The high‑accuracy consensus from AlphaMissense‑Optimized is benign, and the SGM consensus—derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—is also benign. Foldetta results are not available for this variant. Overall, the majority of computational evidence points to a benign impact, which is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.750Conflicting 26-33443387-T-A31.86e-6-5.248Likely Benign0.091Likely BenignLikely Benign0.343Likely Benign-0.36Neutral0.995Probably Damaging0.939Probably Damaging5.03Benign0.06Tolerated4.3240.26710.312830-0.3-9.01
c.2835T>G
H945Q
2D
AIThe SynGAP1 missense variant H945Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. Only two tools, polyPhen‑2 HumDiv and polyPhen‑2 HumVar, predict a pathogenic effect. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for H945Q, and this conclusion is not contradicted by any ClinVar classification (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.849210Binding0.3860.9230.750-5.248Likely Benign0.091Likely BenignLikely Benign0.343Likely Benign-0.36Neutral0.995Probably Damaging0.939Probably Damaging5.03Benign0.06Tolerated4.3240.26710.312830-0.3-9.01
c.3163G>A
G1055R
2D
AIThe SynGAP1 missense variant G1055R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors benign, while Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.982235Disordered0.872113Binding0.3790.9350.875-8.778Likely Pathogenic0.375AmbiguousLikely Benign0.275Likely Benign-0.09Neutral0.970Probably Damaging0.728Possibly Damaging3.31Benign0.08Tolerated0.10130.4733-3-2-4.199.14
c.3163G>C
G1055R
2D
AIThe SynGAP1 missense variant G1055R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. AlphaMissense‑Default is uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign outcome (2 benign vs. 1 pathogenic, 1 uncertain). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence indicates the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.982235Disordered0.872113Binding0.3790.9350.875-8.778Likely Pathogenic0.375AmbiguousLikely Benign0.275Likely Benign-0.09Neutral0.970Probably Damaging0.728Possibly Damaging3.31Benign0.08Tolerated0.10130.4733-3-2-4.199.14
c.3163G>T
G1055W
2D
AIThe SynGAP1 missense variant G1055W is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar status, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.872113Binding0.3790.9350.875-11.436Likely Pathogenic0.317Likely BenignLikely Benign0.367Likely Benign-0.77Neutral0.997Probably Damaging0.946Probably Damaging3.28Benign0.01Affected0.08990.4246-7-2-0.5129.16
c.3164G>A
G1055E
2D
AIThe SynGAP1 missense variant G1055E is catalogued in gnomAD (variant ID 6‑33443716‑G‑A) but has no ClinVar entry. In silico prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a benign effect. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.872113Binding0.3790.9350.8756-33443716-G-A16.21e-7-10.951Likely Pathogenic0.290Likely BenignLikely Benign0.320Likely Benign-0.03Neutral0.901Possibly Damaging0.456Possibly Damaging3.30Benign0.10Tolerated3.7750.15250.4459-20-3.172.06
c.3164G>C
G1055A
2D
AIThe SynGAP1 missense variant G1055A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign, while only polyPhen‑2 HumDiv indicates a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign and the SGM‑Consensus also reports Likely Benign; Foldetta results are unavailable. Overall, the consensus of the available predictions points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.872113Binding0.3790.9350.875-6.835Likely Benign0.083Likely BenignLikely Benign0.244Likely Benign0.15Neutral0.649Possibly Damaging0.148Benign3.30Benign1.00Tolerated0.33500.5144102.214.03
c.3164G>T
G1055V
2D
AIThe SynGAP1 missense variant G1055V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while ESM1b remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.982235Disordered0.872113Binding0.3790.9350.875-7.434In-Between0.114Likely BenignLikely Benign0.399Likely Benign0.26Neutral0.818Possibly Damaging0.222Benign3.28Benign0.17Tolerated0.13990.3694-1-34.642.08
c.2857C>A
P953T
2D
AIThe SynGAP1 missense variant P953T is predicted to be benign by all evaluated in silico tools. Consensus predictions from SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) classify the variant as Likely Benign. High‑accuracy predictors AlphaMissense‑Optimized also report a benign effect. Other pathogenicity predictors—REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM)—uniformly predict benign. No tools predict pathogenicity. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its stability impact remains unknown. The variant is not listed in ClinVar and has no entry in gnomAD, so no population frequency or clinical classification is available. Based on the unanimous benign predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.920633Binding0.4030.9260.750-6.646Likely Benign0.072Likely BenignLikely Benign0.075Likely Benign-0.80Neutral0.009Benign0.015Benign2.88Benign0.24Tolerated0.22610.60040-10.93.99
c.2857C>G
P953A
2D
AIThe SynGAP1 missense variant P953A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools that assess functional impact all converge on a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. No tool in the dataset indicates pathogenicity. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are not available, so they do not alter the overall assessment. Consequently, the variant is most likely benign based on the collective predictions, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.920633Binding0.4030.9260.750-4.879Likely Benign0.059Likely BenignLikely Benign0.082Likely Benign-0.98Neutral0.124Benign0.061Benign2.81Benign0.41Tolerated0.34760.52031-13.4-26.04
c.2857C>T
P953S
2D
AIThe SynGAP1 missense variant P953S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this trend: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign. Foldetta results are unavailable, so they do not influence the overall assessment. **Thus, the variant is most likely benign, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists.**

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.920633Binding0.4030.9260.750-5.430Likely Benign0.061Likely BenignLikely Benign0.073Likely Benign-0.35Neutral0.009Benign0.008Benign2.96Benign0.37Tolerated0.33590.51841-10.8-10.04
c.2858C>A
P953Q
2D
AIThe SynGAP1 missense variant P953Q is listed in ClinVar with an uncertain significance (ClinVar ID 1176820.0) and is not found in gnomAD. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign effects, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions points to a benign impact, which does not contradict the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.920633Binding0.4030.9260.750Uncertain 1-6.038Likely Benign0.079Likely BenignLikely Benign0.086Likely Benign-0.78Neutral0.058Benign0.015Benign2.78Benign0.29Tolerated3.7750.21050.51080-1-1.931.01
c.2858C>G
P953R
2D
AIThe SynGAP1 missense variant P953R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic outcome, creating a single discordant signal. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence supports a benign classification, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.920633Binding0.4030.9260.750-6.036Likely Benign0.174Likely BenignLikely Benign0.083Likely Benign-1.50Neutral0.611Possibly Damaging0.185Benign2.78Benign0.31Tolerated0.17710.45250-2-2.959.07
c.2858C>T
P953L
2D
AIThe SynGAP1 missense variant P953L is reported in gnomAD (variant ID 6‑33443410‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts it as pathogenic, representing a single dissenting opinion. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods points to a benign effect, and this conclusion is not contradicted by any ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.920633Binding0.4030.9260.7506-33443410-C-T116.82e-6-6.069Likely Benign0.079Likely BenignLikely Benign0.087Likely Benign-1.34Neutral0.611Possibly Damaging0.096Benign2.76Benign0.25Tolerated3.7750.27250.5778-3-35.416.04
c.3160G>A
G1054S
2D
AIThe SynGAP1 missense variant G1054S is listed in ClinVar (ID 699126.0) as Benign and is present in gnomAD (variant ID 6‑33443712‑G‑A). All evaluated in‑silico predictors classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool reports a pathogenic or likely pathogenic outcome. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts Benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the computational evidence strongly supports a benign effect, consistent with the ClinVar designation and not contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.878015Binding0.3890.9360.875Benign 16-33443712-G-A321.99e-5-5.294Likely Benign0.075Likely BenignLikely Benign0.160Likely Benign0.21Neutral0.121Benign0.013Benign4.04Benign0.63Tolerated3.7750.25060.531110-0.430.03
c.3160G>C
G1054R
2D
AIThe SynGAP1 missense variant G1054R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for G1054R, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.878015Binding0.3890.9360.875-8.863Likely Pathogenic0.326Likely BenignLikely Benign0.234Likely Benign0.29Neutral0.988Probably Damaging0.589Possibly Damaging4.05Benign0.42Tolerated0.11640.4342-3-2-4.199.14
c.3160G>T
G1054C
2D
AIThe SynGAP1 missense variant G1054C is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). In contrast, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. No Foldetta stability analysis is available. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.878015Binding0.3890.9360.875-9.548Likely Pathogenic0.118Likely BenignLikely Benign0.297Likely Benign-0.59Neutral0.999Probably Damaging0.907Possibly Damaging4.00Benign0.10Tolerated0.14130.4427-3-32.946.09
c.3161G>A
G1054D
2D
AISynGAP1 missense variant G1054D is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized scores benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence indicates the variant is most likely benign, which does not contradict the current ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.983019Disordered0.878015Binding0.3890.9360.875Uncertain 1-10.385Likely Pathogenic0.351AmbiguousLikely Benign0.279Likely Benign-0.26Neutral0.818Possibly Damaging0.266Benign4.07Benign0.37Tolerated3.7750.18240.20351-1-3.158.04
c.3161G>C
G1054A
2D
AIThe SynGAP1 missense variant G1054A is catalogued in gnomAD (ID 6‑33443713‑G‑C) but has no ClinVar entry. Across a broad panel of in‑silico predictors, every tool reports a benign outcome: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity, so the pathogenic‑prediction group is empty. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no reported result for this variant, so its status is unavailable. Based on the unanimous benign predictions and the lack of any ClinVar pathogenic classification, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.878015Binding0.3890.9360.8756-33443713-G-C-6.786Likely Benign0.078Likely BenignLikely Benign0.243Likely Benign-0.05Neutral0.288Benign0.071Benign4.03Benign1.00Tolerated3.7750.33050.5144012.214.03
c.3161G>T
G1054V
2D
AIThe SynGAP1 missense variant G1054V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as likely benign. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts benign and the SGM‑Consensus also reports likely benign; Foldetta results are unavailable. Overall, the consensus of the available predictions points to a benign impact, and this is consistent with the lack of ClinVar evidence; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.878015Binding0.3890.9360.875-6.994Likely Benign0.110Likely BenignLikely Benign0.171Likely Benign-0.22Neutral0.818Possibly Damaging0.221Benign4.01Benign0.18Tolerated0.15780.3694-1-34.642.08
c.3175G>A
G1059R
2D
AIThe SynGAP1 missense variant G1059R is listed in ClinVar with an uncertain significance and is present in the gnomAD database (ID 6‑33443727‑G‑A). Consensus among most in silico predictors leans toward a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized all report benign. In contrast, SIFT and ESM1b predict pathogenicity, while AlphaMissense‑Default remains uncertain. High‑accuracy assessment consolidates this view: AlphaMissense‑Optimized is benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields a benign classification. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its influence is unavailable. Overall, the preponderance of computational evidence supports a benign interpretation, which is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.983019Disordered0.898939Binding0.3990.9260.875Conflicting 26-33443727-G-A684.23e-5-8.452Likely Pathogenic0.376AmbiguousLikely Benign0.333Likely Benign-0.55Neutral0.001Benign0.001Benign2.53Benign0.00Affected4.3220.10520.4342-3-2-4.199.14
c.3175G>C
G1059R
2D
AIThe SynGAP1 missense variant G1059R is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in silico predictors shows a predominance of benign calls: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized all predict a benign effect, whereas SIFT and ESM1b predict pathogenicity; AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce this trend: AlphaMissense‑Optimized is benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also returns a benign prediction. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the balance of evidence points to a benign impact for G1059R, and this conclusion is consistent with the absence of any ClinVar annotation or gnomAD observation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.983019Disordered0.898939Binding0.3990.9260.875-8.452Likely Pathogenic0.376AmbiguousLikely Benign0.333Likely Benign-0.55Neutral0.001Benign0.001Benign2.53Benign0.00Affected4.3220.10520.4342-3-2-4.199.14
c.3175G>T
G1059W
2D
AIThe SynGAP1 missense variant G1059W is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.898939Binding0.3990.9260.875-11.549Likely Pathogenic0.312Likely BenignLikely Benign0.446Likely Benign-1.18Neutral0.983Probably Damaging0.813Possibly Damaging2.53Benign0.00Affected0.09250.4046-7-2-0.5129.16
c.3176G>A
G1059E
2D
AIThe SynGAP1 missense variant G1059E is reported in gnomAD (variant ID 6‑33443728‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only two tools—SIFT and ESM1b—predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.898939Binding0.3990.9260.8756-33443728-G-A16.22e-7-10.459Likely Pathogenic0.297Likely BenignLikely Benign0.390Likely Benign-0.71Neutral0.126Benign0.066Benign2.53Benign0.00Affected4.3220.14640.4069-20-3.172.06
c.3176G>C
G1059A
2D
AIThe SynGAP1 missense variant G1059A is listed in ClinVar (ID 1420036.0) with an “Uncertain” clinical significance and is present in gnomAD (variant ID 6‑33443728‑G‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of computational evidence supports a benign impact for G1059A, which does not contradict the ClinVar “Uncertain” status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.898939Binding0.3990.9260.875Uncertain 16-33443728-G-C42.49e-6-6.754Likely Benign0.081Likely BenignLikely Benign0.329Likely Benign-0.17Neutral0.001Benign0.002Benign2.56Benign0.00Affected4.3220.32950.4944102.214.03
c.3176G>T
G1059V
2D
AIThe SynGAP1 missense variant G1059V is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in silico predictors indicates a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score benign, while the majority‑vote SGM‑Consensus also classifies it as likely benign. Only SIFT predicts a pathogenic outcome, and ESM1b remains uncertain. High‑accuracy tools corroborate the benign prediction: AlphaMissense‑Optimized is benign and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is likely benign; Foldetta results are not available. Overall, the preponderance of evidence supports a benign classification for G1059V, and this assessment does not conflict with ClinVar, which currently contains no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.983019Disordered0.898939Binding0.3990.9260.875-7.242In-Between0.106Likely BenignLikely Benign0.478Likely Benign-0.82Neutral0.259Benign0.066Benign2.54Benign0.00Affected0.14620.3494-1-34.642.08
c.2860C>A
P954T
2D
AIThe SynGAP1 missense variant P954T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. The variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984159Disordered0.932268Binding0.4650.9260.750-5.657Likely Benign0.072Likely BenignLikely Benign0.089Likely Benign-0.77Neutral0.977Probably Damaging0.856Possibly Damaging2.79Benign0.48Tolerated0.18600.63240-10.93.99
c.2860C>G
P954A
2D
AIThe SynGAP1 missense variant P954A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. There is no ClinVar classification to contradict this conclusion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984159Disordered0.932268Binding0.4650.9260.750-4.985Likely Benign0.051Likely BenignLikely Benign0.072Likely Benign-0.21Neutral0.856Possibly Damaging0.652Possibly Damaging2.91Benign0.90Tolerated0.31030.55501-13.4-26.04
c.2860C>T
P954S
2D
AIThe SynGAP1 missense variant P954S is listed in ClinVar as Benign (ClinVar ID 833606.0) and is present in gnomAD (ID 6‑33443412‑C‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, which is consistent with the ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984159Disordered0.932268Binding0.4650.9260.750Likely Benign 16-33443412-C-T16.20e-7-3.525Likely Benign0.062Likely BenignLikely Benign0.143Likely Benign-0.25Neutral0.954Possibly Damaging0.812Possibly Damaging2.87Benign1.00Tolerated3.7750.30880.56191-10.8-10.04
c.2861C>A
P954H
2D
AIThe SynGAP1 missense variant P954H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar or gnomAD entries—there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984159Disordered0.932268Binding0.4650.9260.750-3.670Likely Benign0.082Likely BenignLikely Benign0.098Likely Benign-0.50Neutral0.041Benign0.067Benign2.75Benign0.04Affected0.20540.47560-2-1.640.02
c.2861C>G
P954R
2D
AIThe SynGAP1 missense variant P954R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (which is “Likely Benign”). In contrast, the two polyPhen‑2 implementations (HumDiv and HumVar) predict a pathogenic impact. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is also likely benign. No Foldetta stability result is available, so it does not influence the assessment. Overall, the majority of evidence indicates that P954R is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984159Disordered0.932268Binding0.4650.9260.750-6.329Likely Benign0.160Likely BenignLikely Benign0.097Likely Benign-1.19Neutral0.954Possibly Damaging0.826Possibly Damaging2.78Benign0.11Tolerated0.15480.39400-2-2.959.07
c.2861C>T
P954L
2D
AIThe SynGAP1 missense variant P954L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict it to be pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984159Disordered0.932268Binding0.4650.9260.750-5.607Likely Benign0.092Likely BenignLikely Benign0.097Likely Benign-0.43Neutral0.977Probably Damaging0.812Possibly Damaging2.78Benign0.55Tolerated0.23460.5867-3-35.416.04
c.3154G>A
G1052R
2D
AISynGAP1 missense variant G1052R is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Functional prediction tools cluster into two groups: benign predictions from REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized scores the variant as benign, and the SGM consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of evidence points to a benign effect, which does not contradict the ClinVar uncertain status but provides additional support toward a likely benign classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.984420Disordered0.892068Binding0.3670.9380.875Uncertain 1-9.050Likely Pathogenic0.383AmbiguousLikely Benign0.497Likely Benign-0.41Neutral0.990Probably Damaging0.798Possibly Damaging3.90Benign0.10Tolerated3.7750.09760.4142-2-3-4.199.14
c.3154G>C
G1052R
2D
AIThe SynGAP1 missense variant G1052R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and ESM1b predict a pathogenic outcome; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.984420Disordered0.892068Binding0.3670.9380.875-9.050Likely Pathogenic0.383AmbiguousLikely Benign0.497Likely Benign-0.41Neutral0.990Probably Damaging0.798Possibly Damaging3.90Benign0.10Tolerated3.7750.09760.4142-2-3-4.199.14
c.3154G>T
G1052W
2D
AIThe SynGAP1 missense variant G1052W is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which classifies the variant as Likely Benign. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984420Disordered0.892068Binding0.3670.9380.875-11.322Likely Pathogenic0.309Likely BenignLikely Benign0.457Likely Benign-0.90Neutral0.997Probably Damaging0.946Probably Damaging3.90Benign0.02Affected0.08720.4046-7-2-0.5129.16
c.3155G>A
G1052E
2D
AIThe SynGAP1 missense variant G1052E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: SGM‑Consensus (Likely Benign), REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a neutral impact. In contrast, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b predict a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates a likely benign effect. Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign classification, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984420Disordered0.892068Binding0.3670.9380.875-9.869Likely Pathogenic0.287Likely BenignLikely Benign0.448Likely Benign-0.64Neutral0.901Possibly Damaging0.537Possibly Damaging3.90Benign0.12Tolerated0.14050.38730-2-3.172.06
c.3155G>C
G1052A
2D
AIThe SynGAP1 missense variant G1052A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic outcome, creating a single discordant signal. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence supports a benign classification, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984420Disordered0.892068Binding0.3670.9380.875-6.945Likely Benign0.086Likely BenignLikely Benign0.382Likely Benign-0.14Neutral0.649Possibly Damaging0.287Benign3.93Benign1.00Tolerated0.32590.4949102.214.03
c.3155G>T
G1052V
2D
AIThe SynGAP1 missense variant G1052V is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate benign, while the high‑accuracy AlphaMissense‑Optimized score is benign and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign. In contrast, polyPhen‑2 HumDiv and HumVar both predict pathogenic, and ESM1b remains uncertain. No Foldetta stability assessment is available, so it does not influence the overall interpretation. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984420Disordered0.892068Binding0.3670.9380.875-7.717In-Between0.094Likely BenignLikely Benign0.452Likely Benign-0.12Neutral0.901Possibly Damaging0.619Possibly Damaging3.90Benign0.19Tolerated0.13290.3499-1-34.642.08
c.2863T>A
S955T
2D
AIThe SynGAP1 missense variant S955T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for S955T, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.945325Binding0.3500.9240.750-4.717Likely Benign0.087Likely BenignLikely Benign0.070Likely Benign-0.96Neutral0.451Benign0.265Benign2.38Pathogenic0.00Affected0.21840.5927110.114.03
c.2863T>C
S955P
2D
AIThe SynGAP1 missense variant S955P is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443415‑T‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Tools that predict a pathogenic effect are SIFT and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this is consistent with the ClinVar “Uncertain” classification rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.945325Binding0.3500.9240.750Uncertain 16-33443415-T-C31.86e-6-2.584Likely Benign0.073Likely BenignLikely Benign0.098Likely Benign-0.75Neutral0.001Benign0.004Benign2.33Pathogenic0.00Affected3.7750.26290.55371-1-0.810.04
c.2863T>G
S955A
2D
AIThe SynGAP1 missense variant S955A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.945325Binding0.3500.9240.750-4.258Likely Benign0.068Likely BenignLikely Benign0.091Likely Benign-0.71Neutral0.004Benign0.006Benign2.41Pathogenic0.00Affected0.42620.5038112.6-16.00
c.2864C>A
S955Y
2D
AIThe SynGAP1 missense variant S955Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also as benign; Foldetta results are unavailable. Overall, the majority of predictions (six benign vs. four pathogenic) support a benign classification. There is no ClinVar entry to contradict this assessment, so the variant is most likely benign based on current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.945325Binding0.3500.9240.750-6.212Likely Benign0.216Likely BenignLikely Benign0.077Likely Benign-1.62Neutral0.977Probably Damaging0.721Possibly Damaging2.32Pathogenic0.00Affected0.13210.4932-3-2-0.576.10
c.2864C>G
S955C
2D
AIThe SynGAP1 missense variant S955C is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. The SGM Consensus, which takes a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (2 benign vs. 2 pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of available predictions (5 pathogenic vs. 4 benign) indicate a likely pathogenic impact. This conclusion is not contradicted by ClinVar status, as the variant has no existing ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.984871Disordered0.945325Binding0.3500.9240.750-8.675Likely Pathogenic0.117Likely BenignLikely Benign0.064Likely Benign-1.48Neutral0.977Probably Damaging0.796Possibly Damaging2.32Pathogenic0.00Affected0.17410.54700-13.316.06
c.2864C>T
S955F
2D
AISynGAP1 missense variant S955F is listed in ClinVar as uncertain and is present in gnomAD (ID 6‑33443416‑C‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM; ESM1b is inconclusive. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also returns benign, and Foldetta results are unavailable. Overall, the majority of high‑confidence predictions favor a benign impact, and this does not contradict the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.984871Disordered0.945325Binding0.3500.9240.750Conflicting 46-33443416-C-T955.89e-5-7.374In-Between0.176Likely BenignLikely Benign0.093Likely Benign-1.73Neutral0.977Probably Damaging0.721Possibly Damaging2.32Pathogenic0.00Affected3.7750.12460.4943-3-23.660.10
c.2866T>A
S956T
2D
AIThe SynGAP1 missense variant S956T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign impact for S956T, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.957345Binding0.3640.9170.750-5.404Likely Benign0.097Likely BenignLikely Benign0.079Likely Benign-0.45Neutral0.369Benign0.159Benign2.00Pathogenic0.08Tolerated0.22440.5727110.114.03
c.2866T>C
S956P
2D
AIThe SynGAP1 missense variant S956P is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.957345Binding0.3640.9170.750-3.526Likely Benign0.082Likely BenignLikely Benign0.157Likely Benign-0.55Neutral0.000Benign0.001Benign1.95Pathogenic0.05Affected0.26700.53371-1-0.810.04
c.2866T>G
S956A
2D
AIThe SynGAP1 missense variant S956A is not reported in ClinVar or gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify it as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports it as likely benign. Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta stability analysis is unavailable. Overall, the collective evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.957345Binding0.3640.9170.750-4.468Likely Benign0.087Likely BenignLikely Benign0.111Likely Benign-0.47Neutral0.112Benign0.039Benign2.18Pathogenic0.13Tolerated0.42390.4838112.6-16.00
c.2867C>A
S956Y
2D
AIThe SynGAP1 missense variant S956Y is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion is consistent with the lack of ClinVar annotation. Thus, the variant is most likely benign, with no contradiction from ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.957345Binding0.3640.9170.750-4.920Likely Benign0.233Likely BenignLikely Benign0.085Likely Benign-0.90Neutral0.411Benign0.097Benign1.93Pathogenic0.22Tolerated0.14490.4932-3-2-0.576.10
c.2867C>G
S956C
2D
AIThe SynGAP1 missense variant S956C is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. The SGM Consensus, which takes a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (two benign vs. two pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of available predictions (five pathogenic vs. four benign) indicate a likely pathogenic impact. This conclusion is not contradicted by ClinVar status, as the variant has no existing ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.984871Disordered0.957345Binding0.3640.9170.750-9.292Likely Pathogenic0.108Likely BenignLikely Benign0.107Likely Benign-0.34Neutral0.938Possibly Damaging0.665Possibly Damaging1.94Pathogenic0.03Affected0.18330.54700-13.316.06
c.2867C>T
S956F
2D
AIThe SynGAP1 missense variant S956F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact. The predictions do not contradict any ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.984871Disordered0.957345Binding0.3640.9170.750-6.654Likely Benign0.226Likely BenignLikely Benign0.101Likely Benign-1.04Neutral0.832Possibly Damaging0.398Benign1.93Pathogenic0.39Tolerated0.13150.4943-3-23.660.10
c.2836G>A
G946R
2D
AIThe SynGAP1 missense variant G946R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while ESM1b is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus itself is Likely Benign. Foldetta results are unavailable. Overall, the majority of computational evidence indicates that G946R is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985417Disordered0.845792Binding0.3570.9200.750-7.127In-Between0.308Likely BenignLikely Benign0.296Likely Benign-0.69Neutral0.818Possibly Damaging0.435Benign4.65Benign0.00Affected0.11570.5133-3-2-4.199.14
c.2836G>C
G946R
2D
AIThe SynGAP1 missense variant G946R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while ESM1b is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus itself is Likely Benign. Foldetta results are unavailable. Overall, the majority of computational evidence indicates that G946R is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985417Disordered0.845792Binding0.3570.9200.750-7.127In-Between0.308Likely BenignLikely Benign0.296Likely Benign-0.69Neutral0.818Possibly Damaging0.435Benign4.65Benign0.00Affected0.11570.5133-3-2-4.199.14
c.2837G>A
G946E
2D
AIThe SynGAP1 missense variant G946E is listed in ClinVar (ID 1299783.0) as benign and is present in gnomAD (6‑33443389‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized, while polyPhen‑2 HumDiv, SIFT, and ESM1b predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, aligning with the ClinVar designation and showing no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985417Disordered0.845792Binding0.3570.9200.750Benign 36-33443389-G-A138.05e-6-8.793Likely Pathogenic0.257Likely BenignLikely Benign0.341Likely Benign-0.51Neutral0.818Possibly Damaging0.355Benign4.58Benign0.00Affected4.3240.16910.48590-2-3.172.06
c.2837G>C
G946A
2D
AIThe SynGAP1 missense variant G946A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for G946A, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985417Disordered0.845792Binding0.3570.9200.750-7.004In-Between0.079Likely BenignLikely Benign0.191Likely Benign0.33Neutral0.649Possibly Damaging0.209Benign4.77Benign0.00Affected0.33780.4957102.214.03
c.2837G>T
G946V
2D
AIThe SynGAP1 missense variant G946V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. ESM1b is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for G946V, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985417Disordered0.845792Binding0.3570.9200.750-7.528In-Between0.109Likely BenignLikely Benign0.368Likely Benign-0.30Neutral0.901Possibly Damaging0.516Possibly Damaging4.57Benign0.00Affected0.15240.3707-1-34.642.08
c.2854G>A
G952S
2D
AIThe SynGAP1 missense variant G952S is listed in ClinVar (ID 1325573.0) with an “Uncertain” clinical significance and is present in gnomAD (variant ID 6‑33443406‑G‑A). All evaluated in‑silico predictors agree on a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. No tool predicts pathogenicity. High‑accuracy assessments reinforce this consensus: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status is unavailable. Overall, the computational evidence strongly supports a benign classification, which is consistent with the ClinVar “Uncertain” status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.910621Binding0.3410.9260.750Conflicting 26-33443406-G-A21.24e-6-6.190Likely Benign0.077Likely BenignLikely Benign0.167Likely Benign0.19Neutral0.000Benign0.002Benign3.31Benign0.07Tolerated3.7750.25090.550210-0.430.03
c.2854G>C
G952R
2D
AIThe SynGAP1 missense variant G952R is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only SIFT predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that G952R is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.910621Binding0.3410.9260.750-5.974Likely Benign0.295Likely BenignLikely Benign0.139Likely Benign-0.93Neutral0.077Benign0.011Benign3.20Benign0.02Affected0.11450.4933-3-2-4.199.14
c.2854G>T
G952C
2D
AIThe SynGAP1 missense variant G952C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. Thus, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.910621Binding0.3410.9260.750-8.599Likely Pathogenic0.088Likely BenignLikely Benign0.272Likely Benign-0.18Neutral0.371Benign0.169Benign3.20Benign0.01Affected0.14580.4439-3-32.946.09
c.2855G>A
G952D
2D
AIThe SynGAP1 missense variant G952D is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools overwhelmingly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is labeled Likely Benign. Only SIFT predicts a pathogenic outcome, and ESM1b remains uncertain. High‑accuracy assessments corroborate the benign trend: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Overall, the computational evidence strongly supports a benign classification, and this is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.910621Binding0.3410.9260.750-7.299In-Between0.274Likely BenignLikely Benign0.241Likely Benign-0.75Neutral0.033Benign0.015Benign3.20Benign0.05Affected0.19280.28261-1-3.158.04
c.2855G>C
G952A
2D
AIThe SynGAP1 missense variant G952A is predicted to be benign by every evaluated in‑silico tool. Benign predictions are reported by REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity, so the pathogenic group is empty. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability method, has no available result for this variant. ClinVar contains no entry for G952A, so there is no conflicting clinical annotation. Overall, the computational evidence indicates the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.910621Binding0.3410.9260.750-5.796Likely Benign0.075Likely BenignLikely Benign0.273Likely Benign-0.20Neutral0.000Benign0.000Benign3.26Benign0.08Tolerated0.33090.4957102.214.03
c.2855G>T
G952V
2D
AIThe SynGAP1 missense variant G952V is listed in ClinVar (ID 2055482.0) with an “Uncertain” status and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while ESM1b remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as “Likely Benign.” High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates that G952V is most likely benign, and this conclusion does not contradict the current ClinVar status of uncertainty.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.910621Binding0.3410.9260.750Uncertain 1-7.074In-Between0.078Likely BenignLikely Benign0.231Likely Benign-0.33Neutral0.000Benign0.000Benign3.20Benign0.02Affected3.7750.15380.3507-1-34.642.08
c.2869C>A
H957N
2D
AIThe SynGAP1 missense variant H957N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only FATHMM predicts a pathogenic outcome. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign status. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.968874Binding0.3620.9150.750-6.804Likely Benign0.090Likely BenignLikely Benign0.053Likely Benign-0.45Neutral0.144Benign0.058Benign2.45Pathogenic0.50Tolerated0.23430.378821-0.3-23.04
c.2869C>G
H957D
2D
AIThe SynGAP1 missense variant H957D is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are ESM1b and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (2 benign vs 2 pathogenic), and Foldetta results are unavailable. Overall, the majority of evidence (7 benign vs 2 pathogenic) supports a benign classification. This prediction is consistent with the lack of ClinVar annotation and gnomAD presence, indicating no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.985964Disordered0.968874Binding0.3620.9150.750-8.777Likely Pathogenic0.237Likely BenignLikely Benign0.149Likely Benign-0.77Neutral0.144Benign0.058Benign2.45Pathogenic0.44Tolerated0.26460.30661-1-0.3-22.05
c.2869C>T
H957Y
2D
AIThe SynGAP1 missense variant H957Y is listed in gnomAD (ID 6‑33443421‑C‑T) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) which reports “Likely Benign.” Pathogenic predictions come from polyPhen‑2 HumDiv and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.968874Binding0.3620.9150.7506-33443421-C-T16.20e-7-6.631Likely Benign0.129Likely BenignLikely Benign0.099Likely Benign-1.00Neutral0.510Possibly Damaging0.147Benign2.42Pathogenic0.10Tolerated3.7750.15600.4906201.926.03
c.2870A>C
H957P
2D
AIThe SynGAP1 H957P missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and FATHMM. The high‑accuracy consensus (SGM‑Consensus) is derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yielding a Likely Benign classification (3 benign vs. 1 pathogenic). AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.968874Binding0.3620.9150.750-6.347Likely Benign0.061Likely BenignLikely Benign0.244Likely Benign-0.61Neutral0.453Possibly Damaging0.105Benign2.42Pathogenic0.13Tolerated0.23000.47010-21.6-40.02
c.2870A>G
H957R
2D
AIThe SynGAP1 missense variant H957R is catalogued in gnomAD (ID 6‑33443422‑A‑G) but has no ClinVar entry. Functional prediction tools uniformly classify it as benign: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all report benign or tolerated outcomes. No tool predicts pathogenicity. Grouping by consensus, all listed predictors fall into the benign category, with no opposing pathogenic calls. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta results are unavailable, so they do not influence the assessment. Overall, the evidence strongly supports a benign classification for H957R, and this conclusion does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.968874Binding0.3620.9150.7506-33443422-A-G16.20e-7-6.723Likely Benign0.183Likely BenignLikely Benign0.105Likely Benign-1.31Neutral0.144Benign0.078Benign2.58Benign0.32Tolerated3.7750.24100.361002-1.319.05
c.2870A>T
H957L
2D
AIThe SynGAP1 missense variant H957L is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only FATHMM predicts a pathogenic outcome. When predictions are grouped by consensus, the benign group contains eight tools, whereas the pathogenic group contains only FATHMM. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a Likely Benign result. Foldetta, a protein‑folding stability method, has no available output for this variant. Overall, the preponderance of evidence indicates that H957L is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.968874Binding0.3620.9150.750-6.598Likely Benign0.090Likely BenignLikely Benign0.296Likely Benign-0.38Neutral0.000Benign0.000Benign2.44Pathogenic0.09Tolerated0.15250.5516-2-37.0-23.98
c.2871T>A
H957Q
2D
AIThe SynGAP1 missense variant H957Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is not contradicted by any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.968874Binding0.3620.9150.750-6.304Likely Benign0.130Likely BenignLikely Benign0.113Likely Benign-0.87Neutral0.255Benign0.105Benign2.54Benign0.56Tolerated0.22270.411430-0.3-9.01
c.2871T>G
H957Q
2D
AIThe SynGAP1 missense variant H957Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is not contradicted by any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.968874Binding0.3620.9150.750-6.304Likely Benign0.130Likely BenignLikely Benign0.113Likely Benign-0.87Neutral0.255Benign0.105Benign2.54Benign0.56Tolerated0.22270.411430-0.3-9.01
c.2872C>A
H958N
2D
AIThe SynGAP1 missense variant H958N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.976011Binding0.3710.9130.750-8.644Likely Pathogenic0.097Likely BenignLikely Benign0.110Likely Benign-0.56Neutral0.836Possibly Damaging0.232Benign4.17Benign1.00Tolerated0.23580.363821-0.3-23.04
c.2872C>G
H958D
2D
AIThe SynGAP1 missense variant H958D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and ESM1b—suggest a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.976011Binding0.3710.9130.750-11.494Likely Pathogenic0.227Likely BenignLikely Benign0.200Likely Benign-0.55Neutral0.925Possibly Damaging0.232Benign4.16Benign0.55Tolerated0.27320.28661-1-0.3-22.05
c.2872C>T
H958Y
2D
AIThe SynGAP1 missense variant H958Y is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and ESM1b—suggest a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not conflict with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.976011Binding0.3710.9130.750-8.393Likely Pathogenic0.132Likely BenignLikely Benign0.129Likely Benign-1.03Neutral0.836Possibly Damaging0.232Benign4.14Benign0.06Tolerated0.17920.4706021.926.03
c.2873A>C
H958P
2D
AIThe SynGAP1 missense variant H958P is listed in ClinVar as a benign alteration (ClinVar ID 1006798.0) and is present in the gnomAD database (gnomAD ID 6‑33443425‑A‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion aligns with the ClinVar benign status, showing no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.976011Binding0.3710.9130.750Benign 16-33443425-A-C21.24e-6-8.369Likely Pathogenic0.068Likely BenignLikely Benign0.204Likely Benign-0.36Neutral0.925Possibly Damaging0.316Benign4.14Benign0.10Tolerated3.7750.22900.47010-21.6-40.02
c.2873A>G
H958R
2D
AIThe SynGAP1 missense variant H958R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.976011Binding0.3710.9130.750-9.188Likely Pathogenic0.169Likely BenignLikely Benign0.134Likely Benign-1.29Neutral0.836Possibly Damaging0.232Benign4.17Benign0.09Tolerated0.24400.341020-1.319.05
c.2873A>T
H958L
2D
AIThe SynGAP1 missense variant H958L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only two tools, SIFT and ESM1b, predict a pathogenic outcome. When the high‑accuracy consensus is considered, the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a likely benign verdict, and AlphaMissense‑Optimized also reports benign. Foldetta predictions are unavailable. Overall, the majority of evidence supports a benign interpretation, and this is consistent with the lack of ClinVar annotation. Thus, the variant is most likely benign and does not contradict existing ClinVar data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.976011Binding0.3710.9130.750-8.422Likely Pathogenic0.087Likely BenignLikely Benign0.181Likely Benign-1.28Neutral0.001Benign0.001Benign4.25Benign0.03Affected0.17230.5338-2-37.0-23.98
c.2874C>A
H958Q
2D
AIThe SynGAP1 missense variant H958Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. The predictions do not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.976011Binding0.3710.9130.750-8.625Likely Pathogenic0.117Likely BenignLikely Benign0.144Likely Benign-0.97Neutral0.925Possibly Damaging0.316Benign4.18Benign0.11Tolerated0.22810.373630-0.3-9.01
c.2874C>G
H958Q
2D
AIThe SynGAP1 missense variant H958Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. The predictions do not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.976011Binding0.3710.9130.750-8.625Likely Pathogenic0.117Likely BenignLikely Benign0.144Likely Benign-0.97Neutral0.925Possibly Damaging0.316Benign4.18Benign0.11Tolerated0.22810.373630-0.3-9.01
c.2875C>A
H959N
2D
AIThe SynGAP1 missense variant H959N is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while only ESM1b predicts it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from multiple independent predictors and high‑accuracy tools indicates that H959N is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.980566Binding0.3330.9050.750-8.811Likely Pathogenic0.104Likely BenignLikely Benign0.115Likely Benign-0.10Neutral0.144Benign0.058Benign4.15Benign0.21Tolerated0.22980.383821-0.3-23.04
c.2875C>G
H959D
2D
AIThe SynGAP1 missense variant H959D is listed in gnomAD (ID 6‑33443427‑C‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, resolves to “Likely Benign” (three benign votes versus one pathogenic). High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar status (none reported). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.980566Binding0.3330.9050.7506-33443427-C-G16.20e-7-12.060Likely Pathogenic0.235Likely BenignLikely Benign0.176Likely Benign-0.73Neutral0.144Benign0.058Benign4.14Benign0.29Tolerated3.7750.25860.3066-11-0.3-22.05
c.2875C>T
H959Y
2D
AIThe SynGAP1 missense variant H959Y is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate a tolerated change, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also classifies it as Likely Benign. In contrast, polyPhen‑2 HumDiv, SIFT, and ESM1b predict a pathogenic impact. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect for H959Y, and this conclusion does not conflict with ClinVar, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.980566Binding0.3330.9050.750-8.367Likely Pathogenic0.146Likely BenignLikely Benign0.140Likely Benign-1.09Neutral0.510Possibly Damaging0.147Benign4.09Benign0.05Affected0.16720.4906021.926.03
c.2876A>C
H959P
2D
AIThe SynGAP1 missense variant H959P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.980566Binding0.3330.9050.750-8.902Likely Pathogenic0.070Likely BenignLikely Benign0.232Likely Benign-0.61Neutral0.453Possibly Damaging0.105Benign4.14Benign0.38Tolerated0.22840.49010-21.6-40.02
c.2876A>G
H959R
2D
AIThe SynGAP1 missense variant H959R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as likely benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.980566Binding0.3330.9050.750-9.459Likely Pathogenic0.182Likely BenignLikely Benign0.162Likely Benign-1.11Neutral0.144Benign0.078Benign4.14Benign0.15Tolerated0.24160.361020-1.319.05
c.2876A>T
H959L
2D
AIThe SynGAP1 missense variant H959L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as likely benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that H959L is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.980566Binding0.3330.9050.750-8.515Likely Pathogenic0.100Likely BenignLikely Benign0.236Likely Benign-1.38Neutral0.000Benign0.000Benign4.14Benign0.09Tolerated0.16980.5538-2-37.0-23.98
c.2877C>A
H959Q
2D
AIThe SynGAP1 missense variant H959Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports it as likely benign. Only ESM1b predicts a pathogenic outcome, representing the sole discordant signal. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that H959Q is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.980566Binding0.3330.9050.750-8.657Likely Pathogenic0.126Likely BenignLikely Benign0.182Likely Benign-0.77Neutral0.255Benign0.105Benign4.15Benign0.10Tolerated0.22640.393630-0.3-9.01
c.2877C>G
H959Q
2D
AIThe SynGAP1 missense variant H959Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the variant as benign, while the single pathogenic prediction comes from ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus itself is benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that H959Q is most likely benign, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.985964Disordered0.980566Binding0.3330.9050.750-8.657Likely Pathogenic0.126Likely BenignLikely Benign0.182Likely Benign-0.77Neutral0.255Benign0.105Benign4.15Benign0.10Tolerated0.22640.393630-0.3-9.01
c.2848G>A
G950S
2D
AIThe SynGAP1 missense variant G950S is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; the Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.888649Binding0.3680.9230.750-5.286Likely Benign0.071Likely BenignLikely Benign0.288Likely Benign0.46Neutral0.004Benign0.008Benign2.32Pathogenic0.52Tolerated0.24590.550210-0.430.03
c.2848G>C
G950R
2D
AIThe SynGAP1 missense variant G950R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for G950R, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.888649Binding0.3680.9230.750-6.929Likely Benign0.318Likely BenignLikely Benign0.388Likely Benign-1.10Neutral0.002Benign0.005Benign2.26Pathogenic0.01Affected0.10090.4733-3-2-4.199.14
c.2848G>T
G950C
2D
AIThe SynGAP1 missense variant G950C is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. The SGM Consensus, which takes a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (2 benign vs. 2 pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of high‑confidence predictors (five pathogenic vs. four benign) indicate a pathogenic impact. This conclusion is not contradicted by ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.888649Binding0.3680.9230.750-9.589Likely Pathogenic0.092Likely BenignLikely Benign0.395Likely Benign-0.35Neutral0.983Probably Damaging0.750Possibly Damaging2.26Pathogenic0.01Affected0.14060.4439-3-32.946.09
c.2849G>A
G950D
2D
AIThe SynGAP1 missense variant G950D is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM, while ESM1b remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign outcome. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.888649Binding0.3680.9230.750-7.515In-Between0.245Likely BenignLikely Benign0.402Likely Benign-0.61Neutral0.411Benign0.131Benign2.26Pathogenic0.02Affected0.18740.28261-1-3.158.04
c.2849G>C
G950A
2D
AIThe SynGAP1 missense variant G950A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only FATHMM predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict, reflecting the majority of benign calls. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.888649Binding0.3680.9230.750-6.557Likely Benign0.081Likely BenignLikely Benign0.339Likely Benign-0.13Neutral0.059Benign0.061Benign2.28Pathogenic0.08Tolerated0.33430.4957102.214.03
c.2849G>T
G950V
2D
AIThe SynGAP1 missense variant G950V is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM, while ESM1b remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields a benign prediction. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence indicates that G950V is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.888649Binding0.3680.9230.750-7.796In-Between0.093Likely BenignLikely Benign0.428Likely Benign-0.91Neutral0.411Benign0.239Benign2.26Pathogenic0.01Affected0.13920.3507-1-34.642.08
c.3148G>A
G1050R
2D
AIThe SynGAP1 missense variant G1050R is catalogued in gnomAD (ID 6‑33443700‑G‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. Only FATHMM predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields a benign verdict, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.906802Binding0.3700.9280.8756-33443700-G-A31.86e-6-6.637Likely Benign0.349AmbiguousLikely Benign0.045Likely Benign-0.68Neutral0.009Benign0.008Benign2.48Pathogenic0.06Tolerated3.7750.09390.4532-2-3-4.199.14
c.3148G>C
G1050R
2D
AIThe SynGAP1 missense variant G1050R is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. Only FATHMM predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, and the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign majority vote. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact; this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.906802Binding0.3700.9280.875-6.637Likely Benign0.349AmbiguousLikely Benign0.045Likely Benign-0.68Neutral0.009Benign0.008Benign2.48Pathogenic0.06Tolerated3.7750.09390.4532-2-3-4.199.14
c.3149G>A
G1050E
2D
AIThe SynGAP1 missense variant G1050E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect. There is no ClinVar entry to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.906802Binding0.3700.9280.875-8.175Likely Pathogenic0.266Likely BenignLikely Benign0.071Likely Benign-0.28Neutral0.411Benign0.171Benign2.50Benign0.08Tolerated0.14180.42580-2-3.172.06
c.3149G>C
G1050A
2D
AIThe SynGAP1 missense variant G1050A is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of all available predictions is that the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.906802Binding0.3700.9280.875-5.514Likely Benign0.074Likely BenignLikely Benign0.047Likely Benign0.18Neutral0.000Benign0.004Benign2.68Benign1.00Tolerated0.33490.5133102.214.03
c.3149G>T
G1050V
2D
AIThe SynGAP1 missense variant G1050V is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; the Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently contains no classification for G1050V.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.906802Binding0.3700.9280.875-6.450Likely Benign0.108Likely BenignLikely Benign0.066Likely Benign-0.83Neutral0.126Benign0.096Benign2.49Pathogenic0.13Tolerated0.12600.3684-1-34.642.08
c.3151G>A
G1051S
2D
AIThe SynGAP1 missense variant G1051S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only FATHMM predicts a pathogenic outcome. When the predictions are grouped, the benign consensus includes eight tools, whereas the pathogenic consensus contains a single tool. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports a benign effect, and the SGM‑Consensus—derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also indicates a likely benign outcome. Foldetta data are unavailable, so no stability inference can be drawn. Overall, the computational evidence overwhelmingly supports a benign classification for G1051S, and this conclusion is consistent with the absence of any ClinVar annotation. Thus, the variant is most likely benign, and this assessment does not contradict ClinVar status, which is currently unreported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.900141Binding0.3580.9360.875-4.742Likely Benign0.079Likely BenignLikely Benign0.445Likely Benign0.10Neutral0.245Benign0.096Benign-0.74Pathogenic0.61Tolerated0.24460.491110-0.430.03
c.3151G>C
G1051R
2D
AIThe SynGAP1 missense variant G1051R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and FATHMM. Two tools (ESM1b and AlphaMissense‑Default) are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because it contains one pathogenic, one benign, and two uncertain calls, and Foldetta results are unavailable. Overall, the balance of evidence favors a benign classification. This conclusion does not contradict ClinVar status, as the variant has no ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.900141Binding0.3580.9360.875-7.907In-Between0.346AmbiguousLikely Benign0.438Likely Benign0.20Neutral0.761Possibly Damaging0.305Benign-0.74Pathogenic0.20Tolerated0.09560.4342-3-2-4.199.14
c.3151G>T
G1051C
2D
AIThe SynGAP1 missense variant G1051C is listed in ClinVar as Pathogenic and is not reported in gnomAD. Functional prediction tools show a split assessment: benign calls come from REVEL, PROVEAN, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized, while pathogenic calls come from polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. High‑accuracy methods give a benign result from AlphaMissense‑Optimized; the SGM Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is tied (2 benign vs. 2 pathogenic) and therefore inconclusive, and Foldetta’s stability prediction is unavailable. Overall, the majority of predictions lean toward a benign effect, which contradicts the ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.900141Binding0.3580.9360.875Likely Pathogenic 1-9.050Likely Pathogenic0.122Likely BenignLikely Benign0.497Likely Benign-0.90Neutral0.971Probably Damaging0.750Possibly Damaging-0.74Pathogenic0.10Tolerated3.7750.13220.4612-3-32.946.09
c.3152G>A
G1051D
2D
AISynGAP1 missense variant G1051D is listed in ClinVar as Benign and is present in gnomAD (variant ID 6‑33443704‑G‑A). Prediction tools that classify the variant as benign include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict pathogenicity are polyPhen‑2 HumDiv, ESM1b, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (two benign versus two pathogenic votes), and Foldetta stability analysis is unavailable. Overall, the balance of evidence favors a benign effect, consistent with the ClinVar annotation and not contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.900141Binding0.3580.9360.875Benign 16-33443704-G-A21.24e-6-9.379Likely Pathogenic0.311Likely BenignLikely Benign0.445Likely Benign-0.31Neutral0.761Possibly Damaging0.239Benign-0.74Pathogenic0.39Tolerated3.7750.18720.2235-11-3.158.04
c.3152G>C
G1051A
2D
AIThe SynGAP1 missense variant G1051A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence indicates a benign effect, and this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987317Disordered0.900141Binding0.3580.9360.875-6.406Likely Benign0.081Likely BenignLikely Benign0.406Likely Benign-0.14Neutral0.009Benign0.004Benign-0.74Pathogenic1.00Tolerated0.33530.4944102.214.03
c.3152G>T
G1051V
2D
AIThe SynGAP1 missense variant G1051V is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33443704‑G‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields a benign prediction (2 benign vs. 1 pathogenic, 1 uncertain). Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign effect for G1051V, and this conclusion does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.987317Disordered0.900141Binding0.3580.9360.8756-33443704-G-T16.20e-7-7.098In-Between0.102Likely BenignLikely Benign0.460Likely Benign-0.62Neutral0.245Benign0.096Benign-0.74Pathogenic0.17Tolerated3.7750.12740.3680-3-14.642.08
c.2878C>A
H960N
2D
AIThe SynGAP1 missense variant H960N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987911Disordered0.983385Binding0.3800.9010.750-8.822Likely Pathogenic0.101Likely BenignLikely Benign0.130Likely Benign-0.57Neutral0.494Possibly Damaging0.129Benign4.19Benign0.40Tolerated0.21370.369521-0.3-23.04
c.2878C>G
H960D
2D
AIThe SynGAP1 missense variant H960D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. The predictions do not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987911Disordered0.983385Binding0.3800.9010.750-12.235Likely Pathogenic0.243Likely BenignLikely Benign0.147Likely Benign-1.09Neutral0.494Possibly Damaging0.170Benign4.19Benign0.31Tolerated0.25040.29231-1-0.3-22.05
c.2878C>T
H960Y
2D
AIThe SynGAP1 missense variant H960Y is reported in gnomAD (ID 6‑33443430‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only two tools predict pathogenicity—polyPhen‑2 HumDiv and ESM1b—while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports likely benign; Foldetta results are unavailable. Overall, the consensus of the majority of prediction algorithms and the high‑accuracy tools points to a benign effect. This conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987911Disordered0.983385Binding0.3800.9010.7506-33443430-C-T16.20e-7-8.181Likely Pathogenic0.158Likely BenignLikely Benign0.097Likely Benign-1.25Neutral0.748Possibly Damaging0.232Benign4.13Benign0.21Tolerated3.7750.14460.4963201.926.03
c.2879A>C
H960P
2D
AIThe SynGAP1 missense variant H960P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987911Disordered0.983385Binding0.3800.9010.750-8.672Likely Pathogenic0.064Likely BenignLikely Benign0.119Likely Benign-0.95Neutral0.494Possibly Damaging0.170Benign4.18Benign0.28Tolerated0.21570.49010-21.6-40.02
c.2879A>G
H960R
2D
AIThe SynGAP1 missense variant H960R is reported in gnomAD (ID 6‑33443431‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only two tools predict pathogenicity—polyPhen‑2 HumDiv and ESM1b—while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports likely benign. No Foldetta stability data are available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987911Disordered0.983385Binding0.3800.9010.7506-33443431-A-G16.20e-7-9.238Likely Pathogenic0.192Likely BenignLikely Benign0.075Likely Benign-1.10Neutral0.494Possibly Damaging0.170Benign4.19Benign0.25Tolerated3.7750.22370.366702-1.319.05
c.2879A>T
H960L
2D
AIThe SynGAP1 missense variant H960L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic prediction comes from ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987911Disordered0.983385Binding0.3800.9010.750-8.386Likely Pathogenic0.108Likely BenignLikely Benign0.130Likely Benign-1.30Neutral0.174Benign0.043Benign4.17Benign0.33Tolerated0.14650.5595-2-37.0-23.98
c.2880C>A
H960Q
2D
AIThe SynGAP1 missense variant H960Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. The predictions do not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987911Disordered0.983385Binding0.3800.9010.750-8.551Likely Pathogenic0.124Likely BenignLikely Benign0.109Likely Benign-0.79Neutral0.748Possibly Damaging0.170Benign4.20Benign0.21Tolerated0.20450.399330-0.3-9.01
c.2880C>G
H960Q
2D
AIThe SynGAP1 missense variant H960Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.987911Disordered0.983385Binding0.3800.9010.750-8.551Likely Pathogenic0.124Likely BenignLikely Benign0.109Likely Benign-0.79Neutral0.748Possibly Damaging0.170Benign4.20Benign0.21Tolerated0.20450.399330-0.3-9.01
c.2851C>A
H951N
2D
AIThe SynGAP1 missense variant H951N is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the evidence strongly supports a benign classification, and this conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-5.833Likely Benign0.074Likely BenignLikely Benign0.140Likely Benign-0.41Neutral0.011Benign0.018Benign5.43Benign0.16Tolerated0.25900.319721-0.3-23.04
c.2851C>G
H951D
2D
AIThe SynGAP1 missense variant H951D is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated methods. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on current predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-5.901Likely Benign0.188Likely BenignLikely Benign0.186Likely Benign-0.33Neutral0.000Benign0.001Benign5.43Benign0.46Tolerated0.28510.24751-1-0.3-22.05
c.2851C>T
H951Y
2D
AIThe SynGAP1 missense variant H951Y is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Overall, the consensus of high‑accuracy predictors (AlphaMissense‑Optimized and SGM‑Consensus) supports a benign interpretation. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-5.165Likely Benign0.113Likely BenignLikely Benign0.142Likely Benign-1.03Neutral0.000Benign0.001Benign5.61Benign0.10Tolerated0.22470.4112021.926.03
c.2852A>C
H951P
2D
AIThe SynGAP1 missense variant H951P is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the collective evidence strongly supports a benign classification, and this conclusion is consistent with the lack of a ClinVar entry, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-2.798Likely Benign0.051Likely BenignLikely Benign0.312Likely Benign-0.06Neutral0.000Benign0.001Benign5.43Benign0.14Tolerated0.27450.37070-21.6-40.02
c.2852A>G
H951R
2D
AIThe SynGAP1 missense variant H951R is listed in ClinVar as Pathogenic (ClinVar ID 1003739.0) and is not reported in gnomAD. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign. The Foldetta protein‑folding stability analysis is unavailable for this variant. Based on the collective predictions, the variant is most likely benign, which contradicts its ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750Likely Pathogenic 1-4.964Likely Benign0.125Likely BenignLikely Benign0.185Likely Benign-1.08Neutral0.048Benign0.029Benign5.46Benign0.24Tolerated3.7750.28080.322020-1.319.05
c.2852A>T
H951L
2D
AIThe SynGAP1 missense variant H951L is not reported in ClinVar and is absent from gnomAD, indicating no documented clinical or population evidence. Functional prediction tools uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict a benign effect. No tool in the dataset indicates pathogenicity. High‑accuracy assessments corroborate this benign prediction: AlphaMissense‑Optimized reports a benign outcome, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification. Foldetta results are not available, so they do not influence the assessment. Overall, the variant is most likely benign, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-4.822Likely Benign0.087Likely BenignLikely Benign0.192Likely Benign-0.99Neutral0.022Benign0.018Benign5.47Benign0.43Tolerated0.22240.4526-2-37.0-23.98
c.2853T>A
H951Q
2D
AIThe SynGAP1 missense variant H951Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-4.755Likely Benign0.089Likely BenignLikely Benign0.172Likely Benign-0.51Neutral0.001Benign0.002Benign5.43Benign0.29Tolerated0.27570.332830-0.3-9.01
c.2853T>G
H951Q
2D
AIThe SynGAP1 missense variant H951Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.901477Binding0.4150.9250.750-4.755Likely Benign0.089Likely BenignLikely Benign0.171Likely Benign-0.51Neutral0.001Benign0.002Benign5.43Benign0.29Tolerated0.27570.332830-0.3-9.01
c.3166G>A
G1056S
2D
AIThe SynGAP1 missense variant G1056S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only FATHMM predicts a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.868632Binding0.4020.9350.875-5.252Likely Benign0.080Likely BenignLikely Benign0.339Likely Benign-0.28Neutral0.451Benign0.149Benign1.87Pathogenic0.55Tolerated0.24970.570210-0.430.03
c.3166G>C
G1056R
2D
AIThe SynGAP1 missense variant G1056R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are ESM1b and FATHMM, while AlphaMissense‑Default remains uncertain. High‑accuracy assessment shows AlphaMissense‑Optimized as benign, the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) favors a pathogenic outcome, and Foldetta data are unavailable. Overall, the majority of conventional predictors indicate a benign impact, whereas the SGM Consensus suggests pathogenicity. Given the preponderance of benign predictions and the lack of ClinVar evidence, the variant is most likely benign, and this assessment does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988291Disordered0.868632Binding0.4020.9350.875-9.358Likely Pathogenic0.390AmbiguousLikely Benign0.410Likely Benign0.12Neutral0.011Benign0.010Benign1.83Pathogenic0.13Tolerated0.11270.4533-3-2-4.199.14
c.3166G>T
G1056C
2D
AIThe SynGAP1 missense variant G1056C is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive (2 benign vs 2 pathogenic), and Foldetta results are unavailable. Overall, the balance of evidence leans toward a benign impact. This conclusion does not contradict ClinVar status, as the variant has no ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988291Disordered0.868632Binding0.4020.9350.875-9.974Likely Pathogenic0.122Likely BenignLikely Benign0.432Likely Benign-0.70Neutral0.994Probably Damaging0.777Possibly Damaging1.83Pathogenic0.06Tolerated0.14140.4439-3-32.946.09
c.3167G>A
G1056D
2D
AIThe SynGAP1 missense variant G1056D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, ESM1b, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (2 benign vs. 2 pathogenic), and Foldetta results are unavailable. Overall, the majority of evidence (six benign vs. three pathogenic) supports a benign classification. This conclusion does not contradict ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988291Disordered0.868632Binding0.4020.9350.875-10.352Likely Pathogenic0.328Likely BenignLikely Benign0.380Likely Benign0.09Neutral0.666Possibly Damaging0.193Benign1.83Pathogenic0.92Tolerated0.19120.26261-1-3.158.04
c.3167G>C
G1056A
2D
AIThe SynGAP1 missense variant G1056A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while ESM1b remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign consensus (2 benign vs. 1 pathogenic, with one uncertain). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988291Disordered0.868632Binding0.4020.9350.875-7.458In-Between0.086Likely BenignLikely Benign0.325Likely Benign-0.25Neutral0.264Benign0.097Benign1.85Pathogenic0.49Tolerated0.33250.4957102.214.03
c.3167G>T
G1056V
2D
AIThe SynGAP1 missense variant G1056V is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are ESM1b and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive (2 benign vs 2 pathogenic), and Foldetta results are unavailable. Overall, the majority of evidence (7 benign vs 2 pathogenic) supports a benign classification. This consensus does not contradict ClinVar status, which has no entry for this variant. Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988291Disordered0.868632Binding0.4020.9350.875-8.130Likely Pathogenic0.097Likely BenignLikely Benign0.448Likely Benign-0.24Neutral0.292Benign0.110Benign1.83Pathogenic0.08Tolerated0.14880.3507-1-34.642.08
c.3169A>C
S1057R
2D
AIThe SynGAP1 missense variant S1057R is catalogued in gnomAD (ID 6‑33443721‑A‑C) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.8756-33443721-A-C-6.648Likely Benign0.379AmbiguousLikely Benign0.221Likely Benign-0.24Neutral0.677Possibly Damaging0.168Benign5.30Benign0.21Tolerated3.7750.15840.3620-10-3.769.11
c.3169A>G
S1057G
2D
AIThe SynGAP1 missense variant S1057G is reported in gnomAD (ID 6‑33443721‑A‑G) but has no ClinVar entry. All evaluated in‑silico predictors uniformly classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. The high‑accuracy consensus methods likewise support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are unavailable. Consequently, the variant is most likely benign based on current predictions, and this assessment does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.8756-33443721-A-G17.20e-7-1.005Likely Benign0.049Likely BenignLikely Benign0.211Likely Benign-0.47Neutral0.421Benign0.111Benign5.76Benign0.52Tolerated3.7750.26540.4846010.4-30.03
c.3169A>T
S1057C
2D
AIThe SynGAP1 missense variant S1057C is reported in gnomAD (ID 6‑33443721‑A‑T) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Two tools, polyPhen‑2 HumDiv and polyPhen‑2 HumVar, predict a pathogenic impact, while ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar classification (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.8756-33443721-A-T-7.529In-Between0.100Likely BenignLikely Benign0.258Likely Benign-0.64Neutral0.977Probably Damaging0.683Possibly Damaging5.23Benign0.10Tolerated3.7750.18560.6106-103.316.06
c.3170G>A
S1057N
2D
AIThe SynGAP1 missense variant S1057N is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. All available in‑silico predictors classify the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all return benign scores, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” No tool predicts pathogenicity. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, while Foldetta (combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Overall, the computational evidence overwhelmingly supports a benign effect, and this is consistent with the ClinVar “Uncertain” classification rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.875Uncertain 1-6.386Likely Benign0.117Likely BenignLikely Benign0.218Likely Benign-0.41Neutral0.451Benign0.129Benign5.25Benign0.28Tolerated0.22320.460511-2.727.03
c.3170G>C
S1057T
2D
AIThe SynGAP1 missense variant S1057T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods indicates that the variant is most likely benign, and this assessment is consistent with the lack of ClinVar evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.875-6.375Likely Benign0.079Likely BenignLikely Benign0.241Likely Benign-0.18Neutral0.625Possibly Damaging0.170Benign5.26Benign0.60Tolerated0.22890.5976110.114.03
c.3170G>T
S1057I
2D
AIThe SynGAP1 missense variant S1057I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to the variant being most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.875-6.887Likely Benign0.186Likely BenignLikely Benign0.259Likely Benign-0.87Neutral0.925Possibly Damaging0.238Benign5.24Benign0.07Tolerated0.18020.4980-1-25.326.08
c.3171C>A
S1057R
2D
AIThe SynGAP1 missense variant S1057R is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign. Only polyPhen‑2 HumDiv flags it as pathogenic, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.875-6.648Likely Benign0.379AmbiguousLikely Benign0.272Likely Benign-0.24Neutral0.677Possibly Damaging0.168Benign5.30Benign0.21Tolerated3.7750.15840.3620-10-3.769.11
c.3171C>G
S1057R
2D
AIThe SynGAP1 missense variant S1057R is catalogued in gnomAD (ID 6‑33443723‑C‑G) but has no ClinVar submission. Functional prediction tools largely converge on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all report benign or tolerated. Only polyPhen‑2 HumDiv flags it as pathogenic, while AlphaMissense‑Default remains uncertain. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus confirms a benign likelihood; Foldetta data are unavailable, so no stability evidence is provided. Taken together, the preponderance of evidence indicates the variant is most likely benign, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.8756-33443723-C-G-6.648Likely Benign0.379AmbiguousLikely Benign0.272Likely Benign-0.24Neutral0.677Possibly Damaging0.168Benign5.30Benign0.21Tolerated3.7750.15840.3620-10-3.769.11
c.2842G>A
G948S
2D
AIThe SynGAP1 missense variant G948S is not reported in ClinVar and is absent from gnomAD. In silico prediction tools that assess sequence conservation and structural impact uniformly classify the variant as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this benign assessment: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the collective evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.862121Binding0.3650.9190.750-4.760Likely Benign0.080Likely BenignLikely Benign0.177Likely Benign1.09Neutral0.068Benign0.026Benign4.57Benign1.00Tolerated0.24660.550210-0.430.03
c.2842G>C
G948R
2D
AIThe SynGAP1 missense variant G948R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and SIFT—suggest a pathogenic impact. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.862121Binding0.3650.9190.750-6.782Likely Benign0.315Likely BenignLikely Benign0.266Likely Benign-0.60Neutral0.818Possibly Damaging0.435Benign4.58Benign0.04Affected0.10690.4933-3-2-4.199.14
c.2842G>T
G948C
2D
AIThe SynGAP1 missense variant G948C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. The high‑accuracy consensus (SGM‑Consensus) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the majority of evidence points to a benign impact. The predictions do not contradict ClinVar status, as no ClinVar assertion exists for this variant. Thus, based on the available computational predictions, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.862121Binding0.3650.9190.750-10.254Likely Pathogenic0.102Likely BenignLikely Benign0.247Likely Benign-0.77Neutral0.997Probably Damaging0.840Possibly Damaging4.50Benign0.04Affected0.14220.4439-3-32.946.09
c.2843G>A
G948D
2D
AIThe SynGAP1 missense variant G948D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.862121Binding0.3650.9190.750-8.423Likely Pathogenic0.267Likely BenignLikely Benign0.279Likely Benign0.15Neutral0.818Possibly Damaging0.266Benign4.55Benign0.11Tolerated0.18710.28261-1-3.158.04
c.2843G>C
G948A
2D
AIThe SynGAP1 missense variant G948A is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. Foldetta results are unavailable. Overall, the consensus of all available predictions points to a benign impact, and this conclusion is consistent with the lack of a ClinVar classification, so there is no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.862121Binding0.3650.9190.750-5.627Likely Benign0.078Likely BenignLikely Benign0.189Likely Benign0.04Neutral0.288Benign0.103Benign4.64Benign0.39Tolerated0.33500.4957102.214.03
c.2843G>T
G948V
2D
AIThe SynGAP1 missense variant G948V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods indicates that G948V is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.862121Binding0.3650.9190.750-6.541Likely Benign0.102Likely BenignLikely Benign0.256Likely Benign-0.48Neutral0.901Possibly Damaging0.435Benign4.52Benign0.06Tolerated0.14640.3507-1-34.642.08
c.2893C>A
H965N
2D
AIThe SynGAP1 missense variant H965N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Across the available in‑silico predictors, the majority (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized) uniformly predict a benign effect, while no tool predicts pathogenicity. ESM1b is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign; Foldetta results are not available. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.978700Binding0.3420.8820.750-7.605In-Between0.082Likely BenignLikely Benign0.076Likely Benign-0.50Neutral0.000Benign0.001Benign4.09Benign0.80Tolerated0.23600.383821-0.3-23.04
c.2893C>G
H965D
2D
AIThe SynGAP1 missense variant H965D is reported in gnomAD (6‑33443445‑C‑G) and has no ClinVar entry. Consensus from most in silico predictors—REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—classifies the change as benign, while only the ESM1b model flags it as pathogenic. High‑accuracy assessments reinforce the benign prediction: AlphaMissense‑Optimized returns a benign score, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, did not provide a result for this residue, so its status is unavailable. Overall, the preponderance of evidence indicates that H965D is most likely benign, and this assessment does not contradict any ClinVar classification because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.978700Binding0.3420.8820.7506-33443445-C-G16.20e-7-9.827Likely Pathogenic0.192Likely BenignLikely Benign0.147Likely Benign-0.94Neutral0.007Benign0.018Benign4.09Benign0.62Tolerated3.7750.26970.3066-11-0.3-22.05
c.2893C>T
H965Y
2D
AIThe SynGAP1 missense variant H965Y is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all score the substitution as tolerated. The consensus score from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” No tool predicts pathogenicity, and the single uncertain result from ESM1b does not alter the overall benign consensus. High‑accuracy methods corroborate this: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and Foldetta data are unavailable. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.978700Binding0.3420.8820.750-7.121In-Between0.133Likely BenignLikely Benign0.092Likely Benign-1.02Neutral0.327Benign0.147Benign4.03Benign0.25Tolerated0.15820.4906021.926.03
c.2894A>C
H965P
2D
AIThe SynGAP1 missense variant H965P is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. No tool predicts pathogenicity. The high‑accuracy consensus methods also support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta results are unavailable. Overall, the variant is most likely benign, and this prediction does not contradict any ClinVar status, as no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.978700Binding0.3420.8820.750-6.835Likely Benign0.059Likely BenignLikely Benign0.245Likely Benign-0.69Neutral0.000Benign0.001Benign4.06Benign0.19Tolerated0.23420.49010-21.6-40.02
c.2894A>G
H965R
2D
AIThe SynGAP1 missense variant H965R is catalogued in gnomAD (ID 6‑33443446‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all classify the change as benign or likely benign. No tool predicts pathogenicity; ESM1b is uncertain but does not contradict the benign consensus. High‑accuracy assessments confirm this view: AlphaMissense‑Optimized reports a benign effect, and the SGM‑Consensus likewise indicates a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no reported result for this variant, so it does not influence the assessment. Overall, the available predictions strongly suggest that H965R is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.978700Binding0.3420.8820.7506-33443446-A-G16.20e-7-7.056In-Between0.156Likely BenignLikely Benign0.104Likely Benign-0.88Neutral0.065Benign0.049Benign4.08Benign0.38Tolerated3.7750.23940.361002-1.319.05
c.2894A>T
H965L
2D
AIThe SynGAP1 missense variant H965L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect. Benign predictors include REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized; no tool in the dataset returned a pathogenic prediction. Consensus predictors such as SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) classify the variant as Likely Benign. High‑accuracy methods corroborate this: AlphaMissense‑Optimized is benign, and the SGM Consensus is Likely Benign; Foldetta results are not available. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.978700Binding0.3420.8820.750-6.708Likely Benign0.091Likely BenignLikely Benign0.128Likely Benign-1.66Neutral0.033Benign0.018Benign4.06Benign1.00Tolerated0.16060.5338-2-37.0-23.98
c.2895C>A
H965Q
2D
AIThe SynGAP1 missense variant H965Q is not reported in ClinVar and is absent from gnomAD. In silico prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. No pathogenic predictions are present among the evaluated tools. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.978700Binding0.3420.8820.750-6.447Likely Benign0.101Likely BenignLikely Benign0.042Likely Benign-0.71Neutral0.138Benign0.105Benign4.09Benign0.28Tolerated0.22570.393630-0.3-9.01
c.2895C>G
H965Q
2D
AIThe SynGAP1 missense variant H965Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect. Consensus predictors such as SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) classify the variant as Likely Benign. Individual algorithms—REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized—all predict a benign outcome. No tool in the dataset returned a pathogenic prediction. High‑accuracy methods: AlphaMissense‑Optimized is benign; SGM‑Consensus is Likely Benign; Foldetta results are not available. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988505Disordered0.978700Binding0.3420.8820.750-6.447Likely Benign0.101Likely BenignLikely Benign0.043Likely Benign-0.71Neutral0.138Benign0.105Benign4.09Benign0.28Tolerated0.22570.393630-0.3-9.01
c.2839G>A
G947R
2D
AIThe SynGAP1 missense variant G947R is listed in gnomAD (6-33443391-G-A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Optimized) and pathogenic (SIFT). Two tools remain uncertain (ESM1b, AlphaMissense‑Default). High‑accuracy assessments show AlphaMissense‑Optimized predicts a benign effect, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—does not reach a definitive conclusion (two benign, two uncertain). Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no reported result for this variant. Overall, the preponderance of evidence points to a benign impact, and this assessment does not contradict any ClinVar status, as none is available.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988695Disordered0.850554Binding0.3580.9190.7506-33443391-G-A63.72e-6-7.481In-Between0.343AmbiguousLikely Benign0.273Likely Benign-0.60Neutral0.411Benign0.140Benign4.94Benign0.04Affected4.3240.10340.4733-2-3-4.199.14
c.2839G>C
G947R
2D
AIThe SynGAP1 missense variant G947R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while ESM1b and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive, and Foldetta stability analysis is unavailable. Overall, the balance of evidence favors a benign classification, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988695Disordered0.850554Binding0.3580.9190.750-7.481In-Between0.343AmbiguousLikely Benign0.273Likely Benign-0.60Neutral0.411Benign0.140Benign4.94Benign0.04Affected4.3240.10340.4733-2-3-4.199.14
c.2839G>T
G947W
2D
AIThe SynGAP1 missense variant G947W has no ClinVar record and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988695Disordered0.850554Binding0.3580.9190.750-10.819Likely Pathogenic0.285Likely BenignLikely Benign0.349Likely Benign-1.21Neutral0.983Probably Damaging0.868Possibly Damaging4.90Benign0.01Affected0.09140.4059-7-2-0.5129.16
c.2840G>A
G947E
2D
AIThe SynGAP1 missense variant G947E is reported in ClinVar as “Not submitted” and is present in gnomAD (variant ID 6-33443392-G-A). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome, creating a single discordant signal. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is also likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that G947E is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988695Disordered0.850554Binding0.3580.9190.7506-33443392-G-A16.20e-7-9.574Likely Pathogenic0.243Likely BenignLikely Benign0.302Likely Benign0.08Neutral0.126Benign0.096Benign4.92Benign0.10Tolerated4.3240.15550.4259-20-3.172.06
c.2840G>C
G947A
2D
AIThe SynGAP1 missense variant G947A is listed in ClinVar (ID 1595137) as Benign and is present in gnomAD (variant ID 6‑33443392‑G‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool in the dataset predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is Likely Benign, and Foldetta results are unavailable. Overall, the computational evidence strongly indicates that the variant is most likely benign, and this conclusion is consistent with the ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988695Disordered0.850554Binding0.3580.9190.750Benign/Likely benign 26-33443392-G-C281.73e-5-6.511Likely Benign0.080Likely BenignLikely Benign0.156Likely Benign-0.41Neutral0.224Benign0.131Benign4.97Benign0.10Tolerated4.3240.33750.4957102.214.03
c.2840G>T
G947V
2D
AIThe SynGAP1 missense variant G947V is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all indicate benign, whereas polyPhen‑2 HumDiv and SIFT predict pathogenicity; ESM1b remains uncertain. High‑accuracy methods reinforce the benign assessment: AlphaMissense‑Optimized scores benign, the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign,” and Foldetta data are not available. Overall, the preponderance of evidence points to a benign impact for G947V, and this conclusion is consistent with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988695Disordered0.850554Binding0.3580.9190.750-7.171In-Between0.105Likely BenignLikely Benign0.296Likely Benign-1.11Neutral0.586Possibly Damaging0.303Benign4.93Benign0.01Affected0.14430.3507-1-34.642.08
c.2845G>A
G949S
2D
AIThe SynGAP1 missense variant G949S is listed in ClinVar as a benign alteration (ClinVar ID 212352.0) and is present in the gnomAD database (6‑33443397‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as likely benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, aligning with the ClinVar classification and indicating no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988861Disordered0.874971Binding0.3650.9230.750Benign/Likely benign 46-33443397-G-A1227.56e-5-5.693Likely Benign0.072Likely BenignLikely Benign0.321Likely Benign0.30Neutral0.611Possibly Damaging0.102Benign2.23Pathogenic0.00Affected4.3240.25280.515910-0.430.0310.1016/j.ajhg.2020.11.011
c.2845G>C
G949R
2D
AIThe SynGAP1 missense variant G949R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Consensus from standard in silico predictors shows a split: benign calls come from REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized, while pathogenic calls come from polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; ESM1b is uncertain. High‑accuracy assessment further supports a benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign outcome, and Foldetta data are unavailable. Overall, the preponderance of evidence indicates the variant is most likely benign, and this conclusion does not conflict with any ClinVar annotation because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988861Disordered0.874971Binding0.3650.9230.750-7.650In-Between0.301Likely BenignLikely Benign0.317Likely Benign-0.14Neutral0.997Probably Damaging0.934Probably Damaging2.21Pathogenic0.01Affected0.10950.4569-3-2-4.199.14
c.2845G>T
G949C
2D
AIThe SynGAP1 missense variant G949C is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. The SGM Consensus, which takes a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (two benign vs. two pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of available predictions (five pathogenic vs. four benign) indicate that the variant is most likely pathogenic. This assessment does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988861Disordered0.874971Binding0.3650.9230.750-10.580Likely Pathogenic0.091Likely BenignLikely Benign0.345Likely Benign-1.02Neutral1.000Probably Damaging0.975Probably Damaging2.21Pathogenic0.01Affected0.14800.4097-3-32.946.09
c.2846G>A
G949D
2D
AIThe SynGAP1 missense variant G949D is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. The SGM Consensus, which takes a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (2 benign vs. 2 pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of high‑confidence predictors (5 pathogenic vs. 4 benign) indicate a pathogenic impact. This conclusion is not contradicted by ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988861Disordered0.874971Binding0.3650.9230.750-8.692Likely Pathogenic0.239Likely BenignLikely Benign0.316Likely Benign0.25Neutral0.945Possibly Damaging0.753Possibly Damaging2.21Pathogenic0.02Affected0.19270.28261-1-3.158.04
c.2846G>C
G949A
2D
AIThe SynGAP1 missense variant G949A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is “Likely Benign” (3 benign vs. 1 pathogenic votes). High‑accuracy methods confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988861Disordered0.874971Binding0.3650.9230.750-6.838Likely Benign0.072Likely BenignLikely Benign0.274Likely Benign-0.08Neutral0.779Possibly Damaging0.425Benign2.28Pathogenic0.08Tolerated0.33850.4414102.214.03
c.2846G>T
G949V
2D
AIThe SynGAP1 missense variant G949V is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors a benign outcome. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988861Disordered0.874971Binding0.3650.9230.750-7.364In-Between0.102Likely BenignLikely Benign0.328Likely Benign-0.55Neutral0.992Probably Damaging0.834Possibly Damaging2.21Pathogenic0.01Affected0.14930.3165-1-34.642.08
c.2881C>A
H961N
2D
AIThe SynGAP1 missense variant H961N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as likely benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence indicates that H961N is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750-8.561Likely Pathogenic0.096Likely BenignLikely Benign0.084Likely Benign-0.32Neutral0.069Benign0.036Benign4.17Benign0.81Tolerated0.20740.369521-0.3-23.04
c.2881C>G
H961D
2D
AIThe SynGAP1 missense variant H961D is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750-12.522Likely Pathogenic0.224Likely BenignLikely Benign0.115Likely Benign-0.98Neutral0.069Benign0.036Benign4.19Benign0.09Tolerated0.24870.27231-1-0.3-22.05
c.2881C>T
H961Y
2D
AIThe SynGAP1 missense variant H961Y is listed in ClinVar with an uncertain significance (ClinVar ID 862637.0) and is present in gnomAD (ID 6‑33443433‑C‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this is not in conflict with the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750Conflicting 26-33443433-C-T31.86e-6-8.051Likely Pathogenic0.157Likely BenignLikely Benign0.102Likely Benign-1.07Neutral0.716Possibly Damaging0.147Benign4.10Benign0.55Tolerated3.7750.13690.4563021.926.03
c.2882A>C
H961P
2D
AIThe SynGAP1 missense variant H961P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign, while only SIFT and ESM1b predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a Likely Benign verdict (3 benign vs. 1 pathogenic). High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Consequently, the collective evidence indicates that H961P is most likely benign, and this conclusion is not in conflict with ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750-8.434Likely Pathogenic0.071Likely BenignLikely Benign0.210Likely Benign-0.58Neutral0.000Benign0.000Benign4.15Benign0.02Affected0.20610.47010-21.6-40.02
c.2882A>G
H961R
2D
AIThe SynGAP1 missense variant H961R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b. The SGM‑Consensus, which is a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign (3 benign vs. 1 pathogenic). High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750-9.258Likely Pathogenic0.189Likely BenignLikely Benign0.101Likely Benign-0.90Neutral0.144Benign0.078Benign4.16Benign0.02Affected0.22010.326720-1.319.05
c.2882A>T
H961L
2D
AIThe SynGAP1 missense variant H961L is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only SIFT and ESM1b predict pathogenicity, but these are outliers among the consensus. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as likely benign. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, SGM‑Consensus is benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Overall, the preponderance of evidence indicates the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750-8.547Likely Pathogenic0.109Likely BenignLikely Benign0.155Likely Benign-1.21Neutral0.144Benign0.078Benign4.13Benign0.01Affected0.14650.5344-2-37.0-23.98
c.2883C>A
H961Q
2D
AIThe SynGAP1 missense variant H961Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only SIFT and ESM1b predict pathogenicity. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a “Likely Benign” verdict (3 benign vs. 1 pathogenic). High‑accuracy assessments reinforce this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750-8.368Likely Pathogenic0.118Likely BenignLikely Benign0.088Likely Benign-0.49Neutral0.255Benign0.105Benign4.17Benign0.02Affected0.20220.374330-0.3-9.01
c.2883C>G
H961Q
2D
AIThe SynGAP1 missense variant H961Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT and ESM1b predict a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a majority‑benign vote and is reported as “Likely Benign.” High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the available predictions indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.989835Disordered0.984562Binding0.3230.8930.750-8.368Likely Pathogenic0.118Likely BenignLikely Benign0.088Likely Benign-0.49Neutral0.255Benign0.105Benign4.17Benign0.02Affected0.20220.374330-0.3-9.01
c.2890C>A
H964N
2D
AIThe SynGAP1 missense variant H964N is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-8.073Likely Pathogenic0.084Likely BenignLikely Benign0.098Likely Benign-0.30Neutral0.000Benign0.000Benign4.18Benign0.64Tolerated0.19880.349521-0.3-23.04
c.2890C>G
H964D
2D
AIThe SynGAP1 missense variant H964D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic prediction comes from ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-11.061Likely Pathogenic0.207Likely BenignLikely Benign0.124Likely Benign-0.45Neutral0.000Benign0.000Benign4.18Benign0.24Tolerated0.23130.29231-1-0.3-22.05
c.2890C>T
H964Y
2D
AIThe SynGAP1 missense variant H964Y is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. Only SIFT predicts a pathogenic outcome, and ESM1b remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized predicts benign, SGM‑Consensus indicates likely benign, and the Foldetta stability analysis is unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-7.385In-Between0.139Likely BenignLikely Benign0.069Likely Benign-1.13Neutral0.000Benign0.001Benign4.11Benign0.02Affected0.14220.4363021.926.03
c.2891A>C
H964P
2D
AIThe SynGAP1 missense variant H964P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign, while the only pathogenic call comes from SIFT. ESM1b is uncertain, and the SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign consensus. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates likely benign. Foldetta stability analysis is unavailable. Overall, the collective evidence points to a benign impact for H964P, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-7.466In-Between0.063Likely BenignLikely Benign0.156Likely Benign-0.34Neutral0.000Benign0.000Benign4.12Benign0.04Affected0.19780.43010-21.6-40.02
c.2891A>G
H964R
2D
AIThe SynGAP1 missense variant H964R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b. The SGM‑Consensus, which is a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign (3 benign vs. 1 pathogenic). High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-8.275Likely Pathogenic0.163Likely BenignLikely Benign0.129Likely Benign-0.68Neutral0.000Benign0.000Benign4.19Benign0.05Affected0.22370.346720-1.319.05
c.2891A>T
H964L
2D
AIThe SynGAP1 missense variant H964L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. Only SIFT predicts a pathogenic outcome, and ESM1b remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) indicates likely benign; Foldetta stability analysis is unavailable. Overall, the preponderance of evidence points to a benign effect, and this conclusion does not conflict with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-7.568In-Between0.092Likely BenignLikely Benign0.129Likely Benign-1.20Neutral0.000Benign0.000Benign4.15Benign0.02Affected0.14090.5195-2-37.0-23.98
c.2892C>A
H964Q
2D
AIThe SynGAP1 missense variant H964Q is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. The only tool with an uncertain call is ESM1b, and no pathogenic predictions are reported. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments further support this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is likely benign; Foldetta results are unavailable. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-7.279In-Between0.102Likely BenignLikely Benign0.058Likely Benign-0.38Neutral0.000Benign0.000Benign4.18Benign0.07Tolerated0.19690.359330-0.3-9.01
c.2892C>G
H964Q
2D
AIThe SynGAP1 missense variant H964Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the only uncertain result comes from ESM1b. The high‑accuracy consensus methods also support a benign classification: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the evidence overwhelmingly indicates that H964Q is most likely benign, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.990547Disordered0.982486Binding0.3640.8860.750-7.279In-Between0.102Likely BenignLikely Benign0.058Likely Benign-0.38Neutral0.000Benign0.000Benign4.18Benign0.07Tolerated0.19690.359330-0.3-9.01
c.2884C>A
H962N
2D
AIThe SynGAP1 missense variant H962N is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.984483Binding0.3690.8860.750-8.481Likely Pathogenic0.098Likely BenignLikely Benign0.058Likely Benign-0.61Neutral0.174Benign0.045Benign4.18Benign0.24Tolerated0.19570.321621-0.3-23.04
c.2884C>G
H962D
2D
AIThe SynGAP1 missense variant H962D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect. There is no ClinVar entry to contradict this conclusion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.984483Binding0.3690.8860.750-12.472Likely Pathogenic0.237Likely BenignLikely Benign0.178Likely Benign-1.08Neutral0.001Benign0.002Benign4.20Benign0.20Tolerated0.24020.26431-1-0.3-22.05
c.2884C>T
H962Y
2D
AIThe SynGAP1 missense variant H962Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while ESM1b is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as Likely Benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for H962Y, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.984483Binding0.3690.8860.750-7.735In-Between0.167Likely BenignLikely Benign0.093Likely Benign-1.27Neutral0.878Possibly Damaging0.232Benign4.12Benign0.03Affected0.17410.4411021.926.03
c.2885A>C
H962P
2D
AIThe SynGAP1 missense variant H962P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all predict benign. Only two tools—polyPhen‑2 HumDiv and ESM1b—suggest a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.984483Binding0.3690.8860.750-8.419Likely Pathogenic0.066Likely BenignLikely Benign0.197Likely Benign-0.94Neutral0.748Possibly Damaging0.170Benign4.16Benign0.07Tolerated0.20110.43520-21.6-40.02
c.2885A>G
H962R
2D
AIThe SynGAP1 missense variant H962R is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic prediction comes from ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” status. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion is consistent with the lack of any ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.984483Binding0.3690.8860.750-9.166Likely Pathogenic0.212Likely BenignLikely Benign0.117Likely Benign-1.04Neutral0.325Benign0.129Benign4.18Benign0.07Tolerated0.22760.333720-1.319.05
c.2885A>T
H962L
2D
AIThe SynGAP1 missense variant H962L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact for H962L, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.984483Binding0.3690.8860.750-8.478Likely Pathogenic0.108Likely BenignLikely Benign0.151Likely Benign-1.49Neutral0.494Possibly Damaging0.170Benign4.15Benign0.03Affected0.17380.5487-2-37.0-23.98
c.2886C>A
H962Q
2D
AIThe SynGAP1 missense variant H962Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.984483Binding0.3690.8860.750-8.161Likely Pathogenic0.130Likely BenignLikely Benign0.114Likely Benign-1.04Neutral0.325Benign0.045Benign4.19Benign0.06Tolerated0.19430.384430-0.3-9.01
c.2886C>G
H962Q
2D
AIThe SynGAP1 missense variant H962Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect. There is no ClinVar entry to contradict this conclusion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.984483Binding0.3690.8860.750-8.161Likely Pathogenic0.130Likely BenignLikely Benign0.114Likely Benign-1.04Neutral0.325Benign0.045Benign4.19Benign0.06Tolerated0.19430.384430-0.3-9.01
c.2887C>A
H963N
2D
AIThe SynGAP1 missense variant H963N is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical databases.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.983973Binding0.3250.8860.750-8.274Likely Pathogenic0.099Likely BenignLikely Benign0.089Likely Benign-0.21Neutral0.369Benign0.120Benign4.18Benign0.16Tolerated0.20940.359621-0.3-23.04
c.2887C>G
H963D
2D
AIThe SynGAP1 missense variant H963D is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic prediction comes from ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” status. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates benign; Foldetta results are not available. Overall, the consensus of the majority of tools and the high‑accuracy predictions point to a benign impact for H963D, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.983973Binding0.3250.8860.750-12.082Likely Pathogenic0.204Likely BenignLikely Benign0.167Likely Benign-0.81Neutral0.369Benign0.159Benign4.16Benign0.46Tolerated0.24820.30231-1-0.3-22.05
c.2887C>T
H963Y
2D
AIThe SynGAP1 missense variant H963Y is catalogued in gnomAD (ID 6‑33443439‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all indicate a benign or likely benign outcome. Only polyPhen‑2 HumDiv predicts a pathogenic effect, while ESM1b remains uncertain. High‑accuracy assessments confirm this trend: AlphaMissense‑Optimized reports benign, and the SGM‑Consensus likewise classifies the variant as likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.983973Binding0.3250.8860.7506-33443439-C-T16.20e-7-7.557In-Between0.158Likely BenignLikely Benign0.105Likely Benign-1.13Neutral0.812Possibly Damaging0.298Benign4.09Benign0.10Tolerated3.7750.16270.4464201.926.03
c.2888A>C
H963P
2D
AIThe SynGAP1 missense variant H963P is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the substitution as benign. Only ESM1b predicts a pathogenic outcome, while the consensus score from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized reports benign, and the SGM Consensus also indicates Likely Benign; Foldetta data are not available. Overall, the majority of evidence points to a benign effect, and this conclusion is not in conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.983973Binding0.3250.8860.750-8.158Likely Pathogenic0.074Likely BenignLikely Benign0.223Likely Benign-1.10Neutral0.000Benign0.001Benign4.10Benign0.14Tolerated0.21010.44870-21.6-40.02
c.2888A>G
H963R
2D
AIThe SynGAP1 missense variant H963R is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443440‑A‑G). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Only ESM1b predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized reports benign, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign consensus. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no reported result for this variant, so its status is unavailable. Overall, the preponderance of evidence indicates the variant is most likely benign, which does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.983973Binding0.3250.8860.750Uncertain 16-33443440-A-G84.96e-6-8.952Likely Pathogenic0.169Likely BenignLikely Benign0.081Likely Benign-1.28Neutral0.001Benign0.003Benign4.15Benign0.24Tolerated3.7750.23300.338020-1.319.05
c.2888A>T
H963L
2D
AIThe SynGAP1 missense variant H963L is not reported in ClinVar and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. Only ESM1b predicts a pathogenic outcome, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as likely benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized indicates benign, and the SGM‑Consensus likewise suggests a benign effect; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for H963L, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.983973Binding0.3250.8860.750-8.110Likely Pathogenic0.109Likely BenignLikely Benign0.172Likely Benign-1.58Neutral0.224Benign0.091Benign4.13Benign0.43Tolerated0.16260.5680-2-37.0-23.98
c.2889T>A
H963Q
2D
AIThe SynGAP1 missense variant H963Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the only uncertain result comes from ESM1b. The high‑accuracy consensus methods also support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the evidence overwhelmingly indicates that H963Q is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.983973Binding0.3250.8860.750-7.798In-Between0.116Likely BenignLikely Benign0.104Likely Benign-0.75Neutral0.411Benign0.132Benign4.17Benign0.29Tolerated0.21120.397930-0.3-9.01
c.2889T>G
H963Q
2D
AIThe SynGAP1 missense variant H963Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, AlphaMissense‑Default, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity; the only uncertain result comes from ESM1b. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” consensus. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the collective evidence strongly supports a benign classification, and there is no ClinVar annotation to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.991070Disordered0.983973Binding0.3250.8860.750-7.798In-Between0.116Likely BenignLikely Benign0.104Likely Benign-0.75Neutral0.411Benign0.132Benign4.17Benign0.29Tolerated0.21120.397930-0.3-9.01

Found 8751 rows. Show 800 rows per page. Page 11/11 « Previous | Next »