SynGap Missense Server

Table of SynGAP1 Isoform α2 (UniProt Q96PV0-1) Missense Variants.

c.dna Variant SGM Consensus Domain and Structure information: based on WT protein Annotated databases Deep learning-based pathogenicity predictions Folding stability-based pathogenicity predictions Sequence/structure-based pathogenicity predictions Phase Separation Evolutionary/physical properties Molecular Dynamics-based analysis DOI
Domain IUPred2 ANCHOR2 AlphaFold MobiDB PhosphoSitePlus ClinVar gnomAD ESM1b AlphaMissense FoldX Rosetta Foldetta PremPS REVEL PROVEAN PolyPhen-2 HumDiv PolyPhen-2 HumVar FATHMM SIFT PSMutPred PAM Physical SASA Normalized B-factor backbone Normalized B-factor sidechain SynGAP Structural Annotation
Score Prediction Score Prediction pLDDT disorder disorder LTP HTP KL PTM Clinical Status Review Subm. ID Allele count Allele freq. LLR score Prediction Pathogenicity Class Optimized Average ΔΔG Prediction StdDev ΔΔG Prediction ΔΔG Prediction ΔΔG Prediction Score Prediction Score Prediction pph2_prob Prediction pph2_prob Prediction Nervous System Score Prediction Prediction Status Conservation Sequences IP RF SP RF Prediction PAM250 PAM120 Hydropathy Δ MW Δ Average Δ Δ StdDev Δ StdDev Secondary Tertiary bonds Inside out GAP-Ras interface At membrane No effect MD Alert Verdict Description
c.2729G>C
G910A
2D
AIThe SynGAP1 missense variant G910A is listed in ClinVar with an “Uncertain” status (ClinVar ID 2091237.0) and is present in gnomAD (6‑33443281‑G‑C). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. The remaining predictions are uncertain: AlphaMissense‑Default is inconclusive, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as likely benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, which does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.762850Disordered0.707319Binding0.2640.9170.250Uncertain 16-33443281-G-C16.20e-7-3.587Likely Benign0.361AmbiguousLikely Benign0.209Likely Benign-1.43Neutral0.999Probably Damaging0.999Probably Damaging2.78Benign0.10Tolerated3.7750.37530.4544102.214.03
c.425A>G
K142R
2D
AIThe SynGAP1 missense variant K142R is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also favors benign (2 benign vs. 1 pathogenic, 1 uncertain). Foldetta results are unavailable, so they do not influence the assessment. Overall, the collective evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.461924Structured0.558796Binding0.3740.8590.500-9.327Likely Pathogenic0.361AmbiguousLikely Benign0.157Likely Benign-1.87Neutral0.399Benign0.212Benign3.65Benign0.00Affected0.44590.085832-0.628.01
c.1154C>G
S385W
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S385W is listed in ClinVar as Benign (ClinVar ID 218691.0) and is present in gnomAD (ID 6‑33438059‑C‑G). Functional prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, FATHMM, AlphaMissense‑Optimized, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. Predictions that are inconclusive or unavailable are FoldX, Rosetta, Foldetta, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, the SGM Consensus as Benign, and Foldetta as Uncertain. Taken together, the majority of evidence points to a benign impact, which aligns with the ClinVar classification and does not contradict it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.733139Disordered0.425480Uncertain0.3410.9250.750Benign 16-33438059-C-G-9.353Likely Pathogenic0.362AmbiguousLikely Benign0.53Ambiguous0.20.69Ambiguous0.61Ambiguous0.00Likely Benign0.373Likely Benign-0.84Neutral0.986Probably Damaging0.968Probably Damaging4.63Benign0.00Affected4.3230.12720.6670-2-3-0.199.14260.4-71.20.51.30.70.4UncertainSer385 is located in the Gly-rich Ω loop (res. Pro364-Pro398) between two anti-parallel β sheet strands (res. Thr359-Pro364, res. Ala399-Ile411). Because the Ω loop is assumed to directly interact with the membrane, it moves arbitrarily throughout the WT solvent simulations. The Ω loop potentially plays a crucial role in the SynGAP-membrane complex association, stability, and dynamics. However, this aspect cannot be fully addressed through solvent simulations alone.Ω loops are known to play major roles in protein functions that require flexibility, and thus hydrophobic residues like tryptophan are rarely tolerated. Although no major negative structural effects are observed in the variant simulations, Trp385 may exert drastic effects on the SynGAP-membrane complex dynamics and stability. However, since the effects on Gly-rich Ω loop dynamics can only be studied through the SynGAP-membrane complex, no definite conclusions can be drawn.10.1016/j.ajhg.2020.11.011
c.2489C>T
P830L
2D
AIThe SynGAP1 missense variant P830L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also predicts benign. Foldetta results are unavailable. Overall, the majority of reliable predictors lean toward a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.590140Disordered0.618152Binding0.3330.8740.500-3.990Likely Benign0.362AmbiguousLikely Benign0.269Likely Benign-5.31Deleterious1.000Probably Damaging0.999Probably Damaging2.65Benign0.00Affected0.21380.6631-3-35.416.04
c.751A>C
K251Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant K251Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that uniformly indicate a benign effect include REVEL, FoldX, Rosetta, Foldetta, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv and polyPhen‑2 HumVar, while premPS and AlphaMissense‑Default are inconclusive. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as benign. Taken together, the majority of evidence supports a benign classification for K251Q, and this conclusion does not contradict the absence of a ClinVar entry. Based on the aggregate predictions, K251Q is most likely benign, and this is consistent with its absence from ClinVar.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.447574Structured0.226632Uncertain0.7580.3120.125-5.869Likely Benign0.362AmbiguousLikely Benign0.36Likely Benign0.10.42Likely Benign0.39Likely Benign-0.62Ambiguous0.465Likely Benign0.55Neutral0.997Probably Damaging0.879Possibly Damaging5.86Benign0.63Tolerated0.44660.1085110.4-0.04
c.796C>A
L266M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L266M is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, PROVEAN, SIFT, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Two tools remain uncertain: premPS and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, predicts a benign effect. Overall, the majority of tools (six benign vs. four pathogenic, with two uncertain) lean toward a benign classification, and this conclusion is not contradicted by ClinVar status. Thus, the variant is most likely benign based on the collective predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.232838Structured0.297157Uncertain0.9480.2640.000-9.740Likely Pathogenic0.362AmbiguousLikely Benign0.07Likely Benign0.1-0.47Likely Benign-0.20Likely Benign0.95Ambiguous0.288Likely Benign-1.66Neutral1.000Probably Damaging0.999Probably Damaging1.55Pathogenic0.07Tolerated0.05810.285342-1.918.03
c.958G>C
V320L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V320L is listed in ClinVar with an uncertain significance and is present in gnomAD (ID 6‑33437863‑G‑C). Functional prediction tools that agree on benign impact include REVEL, FoldX, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and AlphaMissense‑Optimized. Pathogenic predictions come from polyPhen‑2 HumDiv and FATHMM, while Rosetta, Foldetta, premPS, and AlphaMissense‑Default are inconclusive. The high‑accuracy consensus (SGM Consensus) derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN yields a benign verdict. AlphaMissense‑Optimized also predicts benign, whereas Foldetta remains uncertain. Overall, the majority of evidence points to a benign effect, which does not contradict the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.185198Structured0.419626Uncertain0.9050.2660.125Uncertain 26-33437863-G-C63.72e-6-6.207Likely Benign0.362AmbiguousLikely Benign-0.26Likely Benign0.21.33Ambiguous0.54Ambiguous0.51Ambiguous0.096Likely Benign-1.02Neutral0.900Possibly Damaging0.373Benign1.78Pathogenic0.92Tolerated3.38230.06610.386321-0.414.03245.8-10.20.30.90.10.3XPotentially BenignThe isopropyl side chain of Val310, located in a β hairpin loop linking two anti-parallel β sheet strands (res. Thr305-Asn315, res. Ala322-Asp330), hydrophobically packs with the side chains of nearby residues (e.g., Leu286, Val350, Pro318). The hydrophobic Leu320 side chain mostly forms the same interactions; hence, the residue swap does not seem to negatively affect the protein structure based on the variant simulations.
c.1315C>A
L439M
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant L439M is reported in gnomAD (variant ID 6‑33438220‑C‑A) but has no ClinVar entry. Functional prediction tools that agree on benign impact include REVEL, FoldX, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions come from premPS, polyPhen‑2 (HumDiv and HumVar) and SIFT. Uncertain results are reported by Rosetta, Foldetta, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as likely benign, and Foldetta as inconclusive. Overall, the majority of evidence points to a benign effect; there is no ClinVar classification to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.222385Structured0.281542Uncertain0.9420.2650.0006-33438220-C-A16.20e-7-5.840Likely Benign0.363AmbiguousLikely Benign-0.33Likely Benign0.11.34Ambiguous0.51Ambiguous1.01Destabilizing0.187Likely Benign-1.43Neutral1.000Probably Damaging0.999Probably Damaging3.24Benign0.02Affected3.38250.07200.275324-1.918.03
c.2750C>G
P917R
2D
AIThe SynGAP1 missense variant P917R is listed in ClinVar with an “Uncertain” status and is present in gnomAD (gnomAD ID 6‑33443302‑C‑G). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also as benign, while Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.599170Disordered0.863949Binding0.3140.8620.375Uncertain 16-33443302-C-G53.10e-6-4.475Likely Benign0.363AmbiguousLikely Benign0.142Likely Benign-1.70Neutral0.642Possibly Damaging0.316Benign2.68Benign0.00Affected3.7750.12700.3012-20-2.959.07
c.3284C>T
P1095L
2D
AIThe SynGAP1 missense variant P1095L is catalogued in gnomAD (ID 6‑33443836‑C‑T) but has no ClinVar record. Functional prediction tools cluster into two groups: benign predictions come from REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from PROVEAN, polyPhen‑2 (HumDiv and HumVar), and SIFT; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors benign, and Foldetta data are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.922952Disordered0.979251Binding0.3870.8701.0006-33443836-C-T16.44e-7-4.697Likely Benign0.363AmbiguousLikely Benign0.126Likely Benign-2.78Deleterious0.960Probably Damaging0.604Possibly Damaging2.74Benign0.03Affected3.7750.21990.6347-3-35.416.04
c.2926T>A
F976I
2D
AIThe SynGAP1 missense variant F976I has no ClinVar entry and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.975061Binding0.3110.8940.625-4.595Likely Benign0.364AmbiguousLikely Benign0.148Likely Benign-1.16Neutral0.666Possibly Damaging0.265Benign4.16Benign0.21Tolerated0.27900.2714101.7-34.02
c.3086A>T
Q1029L
2D
AIThe SynGAP1 missense variant Q1029L is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, favors a benign outcome (2 benign vs. 1 pathogenic, with one uncertain). AlphaMissense‑Default remains uncertain, and Foldetta results are unavailable. High‑accuracy predictions therefore point to a benign impact: AlphaMissense‑Optimized is benign, SGM Consensus is benign, and no Foldetta data are available. Overall, the computational evidence indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar claim exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.852992Disordered0.995643Binding0.3750.7340.500-3.984Likely Benign0.364AmbiguousLikely Benign0.067Likely Benign-2.65Deleterious0.891Possibly Damaging0.587Possibly Damaging2.70Benign0.16Tolerated0.06850.5866-2-27.3-14.97
c.3334G>C
E1112Q
2D
AIThe SynGAP1 missense variant E1112Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign. The Foldetta protein‑folding stability analysis is unavailable for this variant. Overall, the preponderance of evidence from multiple in silico predictors and high‑accuracy tools points to a benign impact for E1112Q, and this conclusion does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.894241Disordered0.909381Binding0.3350.9020.875-1.975Likely Benign0.364AmbiguousLikely Benign0.102Likely Benign-0.48Neutral0.611Possibly Damaging0.305Benign2.71Benign0.42Tolerated0.20310.7430220.0-0.98
c.3946A>G
N1316D
2D
AIThe SynGAP1 missense variant N1316D is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33451820‑A‑G). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also leans toward benign, with two benign and one pathogenic prediction among the four considered. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence indicates a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no classification for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.899122Disordered0.971970Binding0.3800.8850.7506-33451820-A-G-2.717Likely Benign0.364AmbiguousLikely Benign0.057Likely Benign-2.80Deleterious0.225Benign0.084Benign3.96Benign0.00Affected3.7750.20950.3745120.00.98
c.637A>G
I213V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 I213V missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). No tool predicts a pathogenic outcome. Predictions that are inconclusive are FoldX, Rosetta, Foldetta, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, while Foldetta’s stability analysis is uncertain. Overall, the evidence strongly favors a benign classification, and this is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.158265Structured0.372201Uncertain0.8500.2950.125-6.133Likely Benign0.364AmbiguousLikely Benign0.67Ambiguous0.20.58Ambiguous0.63Ambiguous0.47Likely Benign0.413Likely Benign-0.69Neutral0.128Benign0.048Benign5.82Benign0.10Tolerated0.10080.295943-0.3-14.03
c.2993C>A
A998D
2D
AIThe SynGAP1 missense variant A998D is not reported in ClinVar and has no entry in gnomAD. Consensus from multiple in‑silico predictors shows a split: benign calls come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic calls arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default remains uncertain. The high‑accuracy assessment indicates that AlphaMissense‑Optimized predicts a benign effect, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports a likely benign outcome, and Foldetta data are unavailable. Overall, the majority of robust predictors lean toward a benign impact. Therefore, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.759478Disordered0.951758Binding0.3180.9020.500-5.481Likely Benign0.365AmbiguousLikely Benign0.122Likely Benign-1.55Neutral0.971Probably Damaging0.690Possibly Damaging4.09Benign0.00Affected0.17540.21430-2-5.344.01
c.2557G>C
G853R
2D
AIThe SynGAP1 missense variant G853R is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. High‑accuracy predictions therefore point to a benign outcome: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and no Foldetta data is available. Overall, the majority of evidence supports a benign classification, which does not contradict the current ClinVar “Uncertain” status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.657645Disordered0.496246Uncertain0.2840.8150.625Uncertain 1-4.749Likely Benign0.366AmbiguousLikely Benign0.091Likely Benign-1.27Neutral0.846Possibly Damaging0.624Possibly Damaging4.18Benign0.00Affected0.09180.4323-3-2-4.199.14
c.1281T>A
H427Q
2D
3DClick to see structure in 3D Viewer
AISynGAP1 H427Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv and SIFT. Predictions that are inconclusive or unavailable are FoldX, Rosetta, Foldetta, premPS, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as likely benign, and Foldetta as uncertain. Overall, the majority of evidence points to a benign effect for H427Q. This conclusion is consistent with the absence of a ClinVar classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.081712Structured0.394261Uncertain0.9620.2870.000-5.858Likely Benign0.367AmbiguousLikely Benign0.77Ambiguous0.10.62Ambiguous0.70Ambiguous0.73Ambiguous0.142Likely Benign-2.41Neutral0.864Possibly Damaging0.088Benign3.52Benign0.02Affected0.15560.338230-0.3-9.01
c.1281T>G
H427Q
2D
3DClick to see structure in 3D Viewer
AISynGAP1 H427Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv and SIFT. Predictions that are inconclusive or unavailable are FoldX, Rosetta, Foldetta, premPS, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as likely benign, and Foldetta as uncertain. Overall, the majority of evidence points to a benign effect for H427Q. This conclusion is consistent with the absence of a ClinVar classification, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.081712Structured0.394261Uncertain0.9620.2870.000-5.858Likely Benign0.367AmbiguousLikely Benign0.77Ambiguous0.10.62Ambiguous0.70Ambiguous0.73Ambiguous0.142Likely Benign-2.41Neutral0.864Possibly Damaging0.088Benign3.52Benign0.02Affected0.15560.338230-0.3-9.01
c.134A>C
N45T
2D
AIThe SynGAP1 missense variant N45T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.401658Structured0.431853Uncertain0.4980.7410.375-2.425Likely Benign0.367AmbiguousLikely Benign0.075Likely Benign-0.81Neutral0.659Possibly Damaging0.775Possibly Damaging4.08Benign0.00Affected0.16420.8318002.8-13.00
c.2308C>A
Q770K
2D
AIThe SynGAP1 missense variant Q770K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and AlphaMissense‑Optimized also reports a benign prediction. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.436924Structured0.923732Binding0.3280.8870.250-4.768Likely Benign0.367AmbiguousLikely Benign0.106Likely Benign-0.72Neutral0.002Benign0.003Benign4.20Benign0.14Tolerated0.19840.473711-0.40.04
c.3188G>A
G1063D
2D
AIThe SynGAP1 missense variant G1063D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is likely benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the computational evidence overwhelmingly supports a benign impact for G1063D, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975134Disordered0.945784Binding0.3940.9130.875-6.950Likely Benign0.367AmbiguousLikely Benign0.057Likely Benign-0.30Neutral0.411Benign0.058Benign4.24Benign0.08Tolerated0.18780.30261-1-3.158.04
c.493A>T
S165C
2D
AIThe SynGAP1 missense variant S165C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also resolves to benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact for S165C, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.429200Structured0.509123Binding0.3240.6440.250-8.425Likely Pathogenic0.367AmbiguousLikely Benign0.304Likely Benign-1.92Neutral0.938Possibly Damaging0.498Possibly Damaging3.94Benign0.00Affected0.13060.55340-13.316.06
c.2606T>A
L869Q
2D
AIThe SynGAP1 missense variant L869Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default remains uncertain, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.501700Disordered0.688653Binding0.2720.8390.250-2.925Likely Benign0.368AmbiguousLikely Benign0.160Likely Benign-0.57Neutral0.970Probably Damaging0.801Possibly Damaging2.60Benign0.06Tolerated0.09770.1203-2-2-7.314.97
c.2942G>C
G981A
2D
AIThe SynGAP1 missense variant G981A is not reported in ClinVar and has no entry in gnomAD, indicating it is not catalogued in these databases. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.798249Disordered0.970320Binding0.2750.8970.625-3.374Likely Benign0.368AmbiguousLikely Benign0.064Likely Benign-0.95Neutral0.561Possibly Damaging0.376Benign3.95Benign0.00Affected0.35120.4925102.214.03
c.2996C>T
S999F
2D
AIThe SynGAP1 missense variant S999F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized independently predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect; this is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.950682Binding0.2620.8970.625-6.206Likely Benign0.368AmbiguousLikely Benign0.072Likely Benign-1.79Neutral0.966Probably Damaging0.837Possibly Damaging2.64Benign0.01Affected0.08650.6337-3-23.660.10
c.3419C>T
T1140I
2D
AIThe SynGAP1 missense variant T1140I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports it as likely benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, and AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of the majority of prediction tools and the high‑accuracy methods indicates that the variant is most likely benign, with no conflict with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.708094Binding0.2930.8541.000-5.205Likely Benign0.368AmbiguousLikely Benign0.058Likely Benign-1.85Neutral0.611Possibly Damaging0.398Benign2.61Benign0.08Tolerated0.09480.46480-15.212.05
c.2189T>A
I730N
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I730N is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar) and SIFT. The remaining tools—premPS, ESM1b, and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a 2‑to‑2 split, and Foldetta, which integrates FoldX‑MD and Rosetta outputs, also predicts benign. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict ClinVar status, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.733139Disordered0.420109Uncertain0.5910.6190.750-7.987In-Between0.369AmbiguousLikely Benign0.09Likely Benign0.20.04Likely Benign0.07Likely Benign0.70Ambiguous0.080Likely Benign-1.60Neutral1.000Probably Damaging0.986Probably Damaging3.46Benign0.02Affected0.09690.0533-2-3-8.00.94
c.3881C>A
A1294D
2D
AIThe SynGAP1 missense variant A1294D is listed in gnomAD (ID 6‑33447929‑C‑A) but has no ClinVar entry. Functional prediction tools show mixed results: benign calls come from REVEL, ESM1b, and AlphaMissense‑Optimized, whereas pathogenic predictions are reported by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessment further clarifies the picture: AlphaMissense‑Optimized predicts a benign effect, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—leans toward pathogenicity. No Foldetta stability analysis is available for this variant. Overall, the majority of evidence points to a pathogenic effect, which is consistent with the lack of a benign ClinVar classification and the presence of the variant in a general population database. Thus, the variant is most likely pathogenic, and this prediction does not contradict any ClinVar status because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.784345Disordered0.895011Binding0.5650.8060.6256-33447929-C-A-4.179Likely Benign0.369AmbiguousLikely Benign0.224Likely Benign-4.17Deleterious0.999Probably Damaging0.995Probably Damaging2.14Pathogenic0.00Affected3.7750.18930.2262-20-5.344.01
c.110C>A
S37Y
2D
AIThe SynGAP1 missense variant S37Y is listed in gnomAD (ID 6‑33423519‑C‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and Foldetta (FoldX‑MD/Rosetta stability assessment) has no available result. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta data is missing. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.642678Disordered0.433492Uncertain0.3170.8060.5006-33423519-C-A16.20e-7-4.447Likely Benign0.370AmbiguousLikely Benign0.132Likely Benign-1.61Neutral0.880Possibly Damaging0.888Possibly Damaging3.90Benign0.00Affected4.3210.12470.5256-2-3-0.576.10
c.1981C>G
Q661E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q661E is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, Rosetta, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. Four tools (FoldX, Foldetta, premPS, AlphaMissense‑Default) give uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta as uncertain. Overall, the majority of available predictions lean toward a benign impact. This conclusion does not contradict the ClinVar status, which currently has no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.048328Structured0.117089Uncertain0.9240.3090.000-12.121Likely Pathogenic0.370AmbiguousLikely Benign0.64Ambiguous0.10.35Likely Benign0.50Ambiguous0.61Ambiguous0.141Likely Benign-2.15Neutral0.988Probably Damaging0.619Possibly Damaging3.42Benign0.03Affected0.11990.2439220.00.98
c.211G>A
D71N
2D
AIThe SynGAP1 D71N missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also reports Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. The variant is most likely benign, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.575842Disordered0.456046Uncertain0.3500.7990.375-4.279Likely Benign0.370AmbiguousLikely Benign0.136Likely Benign-1.25Neutral0.198Benign0.021Benign4.08Benign0.00Affected0.13310.6021210.0-0.98
c.2510T>C
V837A
2D
AIThe SynGAP1 missense variant V837A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.525368Disordered0.626284Binding0.3180.8710.125-1.400Likely Benign0.370AmbiguousLikely Benign0.073Likely Benign-0.41Neutral0.992Probably Damaging0.989Probably Damaging2.70Benign1.00Tolerated0.30580.210600-2.4-28.05
c.3235A>T
S1079C
2D
AIThe SynGAP1 missense variant S1079C is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, FATHMM, and AlphaMissense‑Optimized, whereas pathogenic predictions are made by PROVEAN, polyPhen‑2 (HumDiv and HumVar), and SIFT. Two tools—ESM1b and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive, and Foldetta data are unavailable. Overall, the balance of evidence slightly favors a pathogenic interpretation, with four tools supporting pathogenicity versus three supporting benignity. This assessment does not contradict ClinVar status, as the variant has not yet been classified in that database.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.919029Disordered0.983887Binding0.3070.9000.750-7.333In-Between0.370AmbiguousLikely Benign0.138Likely Benign-2.61Deleterious0.898Possibly Damaging0.477Possibly Damaging3.81Benign0.00Affected0.09490.55360-13.316.06
c.3318A>C
Q1106H
2D
AIThe SynGAP1 missense variant Q1106H is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicting benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic. Foldetta results are unavailable. Overall, the majority of evidence points to a pathogenic impact, and this conclusion does not contradict any ClinVar annotation because no ClinVar status exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.885302Disordered0.952043Binding0.3820.8700.875-4.893Likely Benign0.370AmbiguousLikely Benign0.174Likely Benign-3.03Deleterious0.996Probably Damaging0.992Probably Damaging1.75Pathogenic0.03Affected0.14530.4214300.39.01
c.3318A>T
Q1106H
2D
AIThe SynGAP1 missense variant Q1106H is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicting benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic. Foldetta results are unavailable. Overall, the majority of evidence points to a pathogenic impact, and this conclusion does not contradict any ClinVar annotation because no ClinVar status exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.885302Disordered0.952043Binding0.3820.8700.875-4.893Likely Benign0.370AmbiguousLikely Benign0.174Likely Benign-3.03Deleterious0.996Probably Damaging0.992Probably Damaging1.75Pathogenic0.03Affected0.14530.4214300.39.01
c.1895A>C
N632T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant N632T is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include Foldetta, premPS, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are REVEL, PROVEAN, and FATHMM. The remaining tools—FoldX, Rosetta, and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic. Overall, the majority of predictions lean toward a benign impact, and this does not contradict any ClinVar annotation (none is available). Thus, based on the current computational evidence, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.042364Structured0.041437Uncertain0.9380.2540.000-6.797Likely Benign0.371AmbiguousLikely Benign1.14Ambiguous0.2-0.58Ambiguous0.28Likely Benign0.39Likely Benign0.541Likely Pathogenic-4.48Deleterious0.214Benign0.062Benign-1.49Pathogenic0.13Tolerated0.12950.6809002.8-13.00
c.2013C>A
D671E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant D671E is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools uniformly indicate a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all classify the substitution as benign. The only inconclusive result is AlphaMissense‑Default, which is listed as uncertain; all other high‑accuracy predictors support a benign outcome. In particular, AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) also reports benign. No pathogenic predictions are present. Therefore, based on the available computational evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.194234Structured0.096749Uncertain0.6770.3700.000-3.657Likely Benign0.371AmbiguousLikely Benign-0.17Likely Benign0.10.22Likely Benign0.03Likely Benign0.03Likely Benign0.066Likely Benign-0.83Neutral0.013Benign0.009Benign3.47Benign0.53Tolerated0.15200.6388320.014.03
c.2013C>G
D671E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant D671E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome. The high‑accuracy assessments are consistent: AlphaMissense‑Optimized indicates Benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports Likely Benign; and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts Benign. With all available evidence pointing to a benign effect and no ClinVar record to contradict this, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.194234Structured0.096749Uncertain0.6770.3700.000-3.657Likely Benign0.371AmbiguousLikely Benign-0.17Likely Benign0.10.22Likely Benign0.03Likely Benign0.03Likely Benign0.066Likely Benign-0.83Neutral0.013Benign0.009Benign3.47Benign0.53Tolerated0.15200.6388320.014.03
c.2803G>C
A935P
2D
AIThe SynGAP1 missense variant A935P is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction, and Foldetta results are unavailable. Overall, the majority of high‑confidence tools predict a benign impact, and there is no conflict with ClinVar status. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.736850Disordered0.980490Binding0.2860.8650.625-3.239Likely Benign0.371AmbiguousLikely Benign0.269Likely Benign-2.08Neutral1.000Probably Damaging0.999Probably Damaging2.29Pathogenic0.00Affected0.20620.54661-1-3.426.04
c.3617A>G
K1206R
2D
AIThe SynGAP1 missense variant K1206R is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. AlphaMissense‑Default is uncertain, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because it receives two benign, one pathogenic, and one uncertain signal. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. High‑accuracy AlphaMissense‑Optimized predicts a benign effect, while Foldetta data are missing. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.585406Disordered0.555819Binding0.8930.5690.375-6.357Likely Benign0.371AmbiguousLikely Benign0.126Likely Benign-1.64Neutral0.999Probably Damaging0.995Probably Damaging2.49Pathogenic0.07Tolerated0.38970.094532-0.628.01
c.1563G>C
E521D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense change E521D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Only two tools, polyPhen‑2 HumDiv and HumVar, predict a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as Benign; the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields Likely Benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, reports a Benign effect. No prediction or stability result is missing or inconclusive. Based on the collective evidence, the variant is most likely benign, and this conclusion is consistent with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.086953Structured0.062387Uncertain0.8650.3490.000-4.963Likely Benign0.372AmbiguousLikely Benign0.13Likely Benign0.00.17Likely Benign0.15Likely Benign-0.29Likely Benign0.227Likely Benign1.07Neutral0.986Probably Damaging0.989Probably Damaging3.40Benign0.92Tolerated0.20260.3721320.0-14.03
c.1563G>T
E521D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 E521D missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Prediction tools largely agree on a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) all indicate benign or likely benign. Only two tools—polyPhen‑2 HumDiv and HumVar—predict a pathogenic outcome. The high‑accuracy methods give a consistent benign signal: AlphaMissense‑Optimized is benign, the SGM‑Consensus is likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) is benign. No prediction or folding stability result is missing or inconclusive. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.086953Structured0.062387Uncertain0.8650.3490.000-4.963Likely Benign0.372AmbiguousLikely Benign0.13Likely Benign0.00.17Likely Benign0.15Likely Benign-0.29Likely Benign0.227Likely Benign1.07Neutral0.986Probably Damaging0.989Probably Damaging3.40Benign0.92Tolerated0.20260.3721320.0-14.03
c.2128A>C
K710Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 K710Q missense variant is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions from REVEL, FoldX, Rosetta, Foldetta, premPS, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. The high‑accuracy AlphaMissense‑Optimized score classifies the variant as benign, whereas the SGM Consensus—derived from a majority vote of AlphaMissense‑Default (uncertain), ESM1b (pathogenic), FATHMM (benign), and PROVEAN (pathogenic)—indicates pathogenicity. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, also predicts a benign effect. Overall, the majority of evidence points to a benign impact, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.321458Structured0.370438Uncertain0.9490.3680.000-8.920Likely Pathogenic0.372AmbiguousLikely Benign0.12Likely Benign0.00.02Likely Benign0.07Likely Benign0.49Likely Benign0.183Likely Benign-3.58Deleterious0.999Probably Damaging0.999Probably Damaging3.39Benign0.01Affected0.30430.1214110.4-0.04
c.3256C>G
P1086A
2D
AIThe SynGAP1 missense variant P1086A is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, the SGM Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors benign, and Foldetta data are unavailable. Taken together, the balance of evidence points to a benign effect for P1086A. This conclusion does not conflict with the ClinVar status, which currently contains no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.849326Disordered0.977190Binding0.3930.8851.000-4.317Likely Benign0.372AmbiguousLikely Benign0.206Likely Benign-2.98Deleterious0.999Probably Damaging0.996Probably Damaging2.78Benign0.00Affected0.30840.44631-13.4-26.04
c.3373G>T
G1125W
2D
AIThe SynGAP1 missense variant G1125W is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors a benign outcome. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the balance of evidence, especially from the high‑accuracy tools, points to a benign classification. This conclusion is not contradicted by any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.834292Disordered0.835839Binding0.3390.9230.875-11.684Likely Pathogenic0.372AmbiguousLikely Benign0.402Likely Benign-1.10Neutral1.000Probably Damaging0.999Probably Damaging4.50Benign0.00Affected0.09240.4046-7-2-0.5129.16
c.3887A>C
E1296A
2D
AIThe SynGAP1 missense variant E1296A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. High‑accuracy predictions therefore indicate a benign outcome: AlphaMissense‑Optimized is benign, the SGM Consensus is benign, and Foldetta data are missing. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.837511Disordered0.894444Binding0.5300.8090.625-2.562Likely Benign0.372AmbiguousLikely Benign0.238Likely Benign-4.08Deleterious0.980Probably Damaging0.812Possibly Damaging2.61Benign0.02Affected0.36640.55060-15.3-58.04
c.1430T>C
M477T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M477T has no ClinVar entry and is present in gnomAD (ID 6‑33438462‑T‑C). Prediction tools that agree on a benign effect include REVEL, Rosetta, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv and FATHMM. The remaining tools (FoldX, Foldetta, premPS, AlphaMissense‑Default) return uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors benign (2 benign vs. 1 pathogenic votes); Foldetta remains uncertain. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, which has no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.268042Structured0.408680Uncertain0.7610.2500.0006-33438462-T-C21.24e-6-2.509Likely Benign0.373AmbiguousLikely Benign1.62Ambiguous0.20.16Likely Benign0.89Ambiguous0.51Ambiguous0.273Likely Benign-1.33Neutral0.765Possibly Damaging0.363Benign-1.10Pathogenic0.40Tolerated3.37340.21770.1950-1-1-2.6-30.09
c.2513A>C
N838T
2D
AIThe SynGAP1 missense variant N838T is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, favors a benign outcome (2 benign vs. 1 pathogenic, with one uncertain). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. High‑accuracy predictions therefore point to a benign classification: AlphaMissense‑Optimized is benign, and the SGM Consensus is benign. Consequently, the variant is most likely benign based on current computational evidence, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.622677Disordered0.613320Binding0.2760.8610.250-4.847Likely Benign0.373AmbiguousLikely Benign0.091Likely Benign-2.59Deleterious0.997Probably Damaging0.992Probably Damaging2.69Benign0.12Tolerated0.12790.5586002.8-13.00
c.3335A>C
E1112A
2D
AIThe SynGAP1 missense variant E1112A is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.894241Disordered0.909381Binding0.3350.9020.875-3.227Likely Benign0.373AmbiguousLikely Benign0.096Likely Benign-1.86Neutral0.393Benign0.131Benign2.71Benign0.02Affected0.39290.75280-15.3-58.04
c.3514C>T
H1172Y
2D
AIThe SynGAP1 H1172Y missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports the variant as Likely Benign, while AlphaMissense‑Default remains Uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, SGM‑Consensus as Likely Benign, and the Foldetta stability analysis is unavailable. Based on the preponderance of benign predictions and the lack of pathogenic evidence, the variant is most likely benign. This conclusion is not contradicted by ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.626927Disordered0.673805Binding0.4650.7580.625-2.820Likely Benign0.373AmbiguousLikely Benign0.356Likely Benign-1.01Neutral0.925Possibly Damaging0.529Possibly Damaging5.42Benign0.01Affected0.06930.4335021.926.03
c.3866A>T
K1289M
2D
AIThe SynGAP1 missense variant K1289M is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT uniformly predict a pathogenic impact. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence—including the SGM consensus and AlphaMissense‑Optimized—points to a benign effect. There is no ClinVar entry to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.828700Binding0.5480.7870.625-4.372Likely Benign0.373AmbiguousLikely Benign0.071Likely Benign-1.79Neutral0.938Possibly Damaging0.596Possibly Damaging2.55Benign0.01Affected0.10150.27800-15.83.02
c.608A>C
D203A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 D203A missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, premPS, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as benign. All available predictions and stability analyses point to a benign impact. Therefore, the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
PH0.314870Structured0.427620Uncertain0.7400.4070.125-6.807Likely Benign0.373AmbiguousLikely Benign0.07Likely Benign0.10.49Likely Benign0.28Likely Benign0.12Likely Benign0.174Likely Benign-3.34Deleterious0.941Possibly Damaging0.607Possibly Damaging4.05Benign0.17Tolerated0.25270.41280-25.3-44.01
c.739C>G
Q247E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q247E is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), and FATHMM. Tools that predict a pathogenic effect are premPS, SIFT, and ESM1b. AlphaMissense‑Default is uncertain, while AlphaMissense‑Optimized predicts benign. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a benign consensus (2 benign vs. 1 pathogenic, with the uncertain result treated as unavailable). High‑accuracy assessments confirm benignity: AlphaMissense‑Optimized is benign, Foldetta (combining FoldX‑MD and Rosetta outputs) is benign, and the SGM Consensus is benign. Overall, the collective evidence indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
PH0.490133Structured0.283012Uncertain0.8220.3390.250-13.564Likely Pathogenic0.373AmbiguousLikely Benign0.42Likely Benign0.1-0.26Likely Benign0.08Likely Benign1.04Destabilizing0.474Likely Benign-1.46Neutral0.128Benign0.039Benign5.80Benign0.03Affected0.10550.1476220.00.98
c.73C>G
R25G
2D
AIThe SynGAP1 missense variant R25G is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in‑silico predictors shows a split: benign calls come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic calls arise from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default remains uncertain. When high‑accuracy tools are considered separately, AlphaMissense‑Optimized predicts a benign effect, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome, and Foldetta data are unavailable. Overall, the majority of robust predictors lean toward a benign interpretation. Thus, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.461924Structured0.438941Uncertain0.3730.8900.375-3.533Likely Benign0.373AmbiguousLikely Benign0.122Likely Benign-1.69Neutral0.686Possibly Damaging0.630Possibly Damaging3.95Benign0.00Affected0.36210.3572-3-24.1-99.14
c.818A>G
E273G
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 E273G missense variant has no ClinVar entry and is not reported in gnomAD. Functional prediction tools cluster into two groups: benign predictions from REVEL, premPS, SIFT, and ESM1b; pathogenic predictions from PROVEAN, polyPhen‑2 (HumDiv and HumVar), and FATHMM. Four tools (FoldX, Rosetta, AlphaMissense‑Default, Foldetta) returned uncertain results and are treated as unavailable evidence. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—labels it pathogenic; Foldetta remains uncertain. Given the split between benign and pathogenic signals and the lack of a ClinVar classification, the variant is best described as of uncertain significance, with a slight inclination toward benign based on the most reliable single‑tool prediction. This assessment does not contradict any existing ClinVar status, as none is available.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.071867Structured0.398918Uncertain0.8630.1960.125-4.784Likely Benign0.373AmbiguousLikely Benign-0.65Ambiguous0.2-0.93Ambiguous-0.79Ambiguous-0.46Likely Benign0.225Likely Benign-2.71Deleterious0.896Possibly Damaging0.519Possibly Damaging1.95Pathogenic0.26Tolerated0.27630.33410-23.1-72.06
c.1826G>T
G609V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G609V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions come from premPS and AlphaMissense‑Optimized, whereas the remaining 10 tools (SGM Consensus, REVEL, FoldX, Rosetta, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM) all predict pathogenicity. High‑accuracy assessments further highlight the discordance: AlphaMissense‑Optimized reports a benign effect, whereas the SGM Consensus (a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) and Foldetta (combining FoldX‑MD and Rosetta outputs) both indicate pathogenicity. With the majority of evidence pointing to deleterious impact, the variant is most likely pathogenic, and this assessment does not contradict any ClinVar annotation because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.179055Structured0.203786Uncertain0.8510.2520.000-11.049Likely Pathogenic0.374AmbiguousLikely Benign4.17Destabilizing0.33.77Destabilizing3.97Destabilizing0.34Likely Benign0.734Likely Pathogenic-4.47Deleterious0.974Probably Damaging0.818Possibly Damaging-1.48Pathogenic0.02Affected0.12690.3317-1-34.642.08
c.2296T>C
S766P
2D
AIThe SynGAP1 missense variant S766P is reported in gnomAD (ID 6‑33442454‑T‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while SIFT uniquely predicts it as pathogenic. The remaining tools, ESM1b and AlphaMissense‑Default, are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive, and Foldetta stability analysis is unavailable. Overall, the preponderance of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status, as none is available.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.405110Structured0.923125Binding0.3380.8740.2506-33442454-T-C11.28e-6-7.343In-Between0.374AmbiguousLikely Benign0.193Likely Benign-0.91Neutral0.006Benign0.013Benign4.07Benign0.01Affected3.6460.22160.5862-11-0.810.04
c.2441C>T
A814V
2D
AIThe SynGAP1 missense variant A814V is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority of high‑accuracy predictors (AlphaMissense‑Optimized and the SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also support a benign classification. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact, but these are the only tools in disagreement. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available, so these do not influence the overall inference. Overall, the preponderance of evidence points to a benign effect for A814V, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.411940Structured0.814830Binding0.3680.9020.250-4.147Likely Benign0.374AmbiguousLikely Benign0.119Likely Benign-0.14Neutral0.811Possibly Damaging0.489Possibly Damaging2.71Benign0.83Tolerated0.10880.6197002.428.05
c.290A>C
E97A
2D
AIThe SynGAP1 missense variant E97A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain. High‑accuracy assessments reinforce the benign prediction: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is also likely benign. Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for E97A, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.609018Binding0.3400.8670.625-3.091Likely Benign0.374AmbiguousLikely Benign0.098Likely Benign-0.58Neutral0.880Possibly Damaging0.636Possibly Damaging4.16Benign0.00Affected0.45050.77280-15.3-58.04
c.457A>C
T153P
2D
AIThe SynGAP1 missense variant T153P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. Two tools—ESM1b and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive because it contains two benign and two uncertain calls, and Foldetta data are unavailable. Overall, the balance of evidence leans toward a benign interpretation. This conclusion does not conflict with ClinVar, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.501700Disordered0.502105Binding0.2970.8180.625-7.092In-Between0.374AmbiguousLikely Benign0.269Likely Benign-1.67Neutral0.983Probably Damaging0.725Possibly Damaging4.09Benign0.03Affected0.22700.36600-1-0.9-3.99
c.1291C>A
L431M
2D
AIThe SynGAP1 missense variant L431M (ClinVar ID 4327026) is not found in gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, PROVEAN, FATHMM, AlphaMissense‑Optimized, and Foldetta, whereas premPS, polyPhen‑2 (HumDiv and HumVar), and SIFT all predict a pathogenic outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign; the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign majority; and Foldetta, which integrates FoldX‑MD and Rosetta outputs, also predicts benign. No predictions or stability results are missing or inconclusive. Overall, the majority of computational evidence indicates that the variant is most likely benign, which contradicts the ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.094817Structured0.374755Uncertain0.9590.3000.0001-7.471In-Between0.375AmbiguousLikely Benign0.18Likely Benign0.30.50Ambiguous0.34Likely Benign1.07Destabilizing0.102Likely Benign-1.50Neutral0.995Probably Damaging0.849Possibly Damaging2.94Benign0.02Affected0.07480.312142-1.918.03
c.3163G>A
G1055R
2D
AIThe SynGAP1 missense variant G1055R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors benign, while Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.982235Disordered0.872113Binding0.3790.9350.875-8.778Likely Pathogenic0.375AmbiguousLikely Benign0.275Likely Benign-0.09Neutral0.970Probably Damaging0.728Possibly Damaging3.31Benign0.08Tolerated0.10130.4733-3-2-4.199.14
c.3163G>C
G1055R
2D
AIThe SynGAP1 missense variant G1055R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. AlphaMissense‑Default is uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign outcome (2 benign vs. 1 pathogenic, 1 uncertain). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence indicates the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.982235Disordered0.872113Binding0.3790.9350.875-8.778Likely Pathogenic0.375AmbiguousLikely Benign0.275Likely Benign-0.09Neutral0.970Probably Damaging0.728Possibly Damaging3.31Benign0.08Tolerated0.10130.4733-3-2-4.199.14
c.3347G>A
G1116E
2D
AIThe SynGAP1 missense variant G1116E is reported in gnomAD (variant ID 6-33443899‑G‑A) but has no ClinVar entry. Functional prediction tools uniformly favor a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while AlphaMissense‑Default remains uncertain. No tool predicts pathogenicity. The high‑accuracy consensus (SGM‑Consensus) also indicates a likely benign outcome, and AlphaMissense‑Optimized corroborates this. Foldetta, a protein‑folding stability predictor, was not available for this variant. Overall, the collective evidence strongly supports a benign impact, and this conclusion is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.873279Binding0.3200.9090.7506-33443899-G-A-6.375Likely Benign0.375AmbiguousLikely Benign0.345Likely Benign-0.33Neutral0.043Benign0.022Benign4.06Benign0.07Tolerated4.3220.14670.4069-20-3.172.06
c.3812A>C
E1271A
2D
AIThe SynGAP1 missense variant E1271A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumVar, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, SIFT, and FATHMM. AlphaMissense‑Default remains uncertain. High‑accuracy assessment shows AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves as pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of conventional tools and the high‑accuracy consensus favor a pathogenic interpretation. This prediction does not contradict ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.483068Structured0.767529Binding0.8320.6660.375-3.817Likely Benign0.375AmbiguousLikely Benign0.298Likely Benign-4.79Deleterious0.951Possibly Damaging0.433Benign2.06Pathogenic0.00Affected0.29850.49590-15.3-58.04
c.3175G>A
G1059R
2D
AIThe SynGAP1 missense variant G1059R is listed in ClinVar with an uncertain significance and is present in the gnomAD database (ID 6‑33443727‑G‑A). Consensus among most in silico predictors leans toward a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized all report benign. In contrast, SIFT and ESM1b predict pathogenicity, while AlphaMissense‑Default remains uncertain. High‑accuracy assessment consolidates this view: AlphaMissense‑Optimized is benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields a benign classification. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its influence is unavailable. Overall, the preponderance of computational evidence supports a benign interpretation, which is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.983019Disordered0.898939Binding0.3990.9260.875Conflicting 26-33443727-G-A684.23e-5-8.452Likely Pathogenic0.376AmbiguousLikely Benign0.333Likely Benign-0.55Neutral0.001Benign0.001Benign2.53Benign0.00Affected4.3220.10520.4342-3-2-4.199.14
c.3175G>C
G1059R
2D
AIThe SynGAP1 missense variant G1059R is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in silico predictors shows a predominance of benign calls: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized all predict a benign effect, whereas SIFT and ESM1b predict pathogenicity; AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce this trend: AlphaMissense‑Optimized is benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also returns a benign prediction. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the balance of evidence points to a benign impact for G1059R, and this conclusion is consistent with the absence of any ClinVar annotation or gnomAD observation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.983019Disordered0.898939Binding0.3990.9260.875-8.452Likely Pathogenic0.376AmbiguousLikely Benign0.333Likely Benign-0.55Neutral0.001Benign0.001Benign2.53Benign0.00Affected4.3220.10520.4342-3-2-4.199.14
c.3200C>G
P1067R
2D
AIThe SynGAP1 missense variant P1067R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also predicts benign, while Foldetta’s stability analysis is unavailable. Taken together, the majority of reliable predictors and the high‑accuracy tools indicate a benign impact. This conclusion is not contradicted by ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.966441Disordered0.975099Binding0.4590.9070.875-4.878Likely Benign0.376AmbiguousLikely Benign0.167Likely Benign-2.74Deleterious0.971Probably Damaging0.580Possibly Damaging2.78Benign0.01Affected0.13000.36510-2-2.959.07
c.1174A>C
K392Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant K392Q has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are REVEL and polyPhen‑2 HumDiv. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, SGM‑Consensus as Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as Benign. No prediction or folding stability result is missing or inconclusive. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.541878Disordered0.405672Uncertain0.3190.7020.750-4.243Likely Benign0.377AmbiguousLikely Benign0.13Likely Benign0.00.05Likely Benign0.09Likely Benign0.23Likely Benign0.525Likely Pathogenic-2.09Neutral0.652Possibly Damaging0.161Benign4.61Benign0.06Tolerated0.56120.2106Weaken110.4-0.04
c.2318T>C
M773T
2D
AIThe SynGAP1 missense variant M773T is listed in gnomAD (ID 6‑33442476‑T‑C) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only polyPhen‑2 HumVar predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.408655Structured0.916222Binding0.3250.8930.2506-33442476-T-C11.28e-6-4.225Likely Benign0.377AmbiguousLikely Benign0.112Likely Benign-1.63Neutral0.106Benign0.471Possibly Damaging4.22Benign0.06Tolerated3.6460.21960.1586-1-1-2.6-30.09
c.2539C>G
Q847E
2D
AISynGAP1 missense variant Q847E is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. The remaining tools, ESM1b and AlphaMissense‑Default, return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is unavailable due to no majority, and Foldetta stability analysis is also unavailable. Overall, the predictions are split, providing no clear bias toward benign or pathogenic. Thus the variant is most likely of uncertain significance, which does not contradict its ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.653063Disordered0.577677Binding0.2820.8180.500Uncertain 1-7.864In-Between0.377AmbiguousLikely Benign0.140Likely Benign-2.12Neutral0.649Possibly Damaging0.535Possibly Damaging2.31Pathogenic0.00Affected0.13760.2083220.00.98
c.3122C>A
P1041H
2D
AIThe SynGAP1 missense variant P1041H is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction, and Foldetta’s protein‑folding stability result is unavailable. Overall, the majority of high‑confidence tools predict a benign impact, and there is no conflict with ClinVar status because the variant has not been reported there. Thus, based on current predictions, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.962114Disordered0.967463Binding0.3450.8330.625-5.312Likely Benign0.377AmbiguousLikely Benign0.476Likely Benign-3.32Deleterious0.999Probably Damaging0.917Probably Damaging5.45Benign0.03Affected0.18830.54340-2-1.640.02
c.1921T>C
S641P
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S641P is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, Rosetta, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN and SIFT. The remaining tools (FoldX, Foldetta, premPS, AlphaMissense‑Default) give uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) leaning toward benign, and Foldetta as uncertain. Overall, the majority of reliable predictions indicate a benign impact, and this conclusion does not contradict the lack of ClinVar annotation. Thus, the variant is most likely benign based on current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.125101Structured0.157322Uncertain0.7860.2700.000-6.907Likely Benign0.378AmbiguousLikely Benign1.73Ambiguous1.30.07Likely Benign0.90Ambiguous0.59Ambiguous0.205Likely Benign-3.05Deleterious0.000Benign0.000Benign3.34Benign0.04Affected0.22890.57911-1-0.810.04
c.2294G>A
S765N
2D
AIThe SynGAP1 missense variant S765N (ClinVar ID 2979632.0) is listed as “Uncertain” in ClinVar and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). In contrast, PolyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is also benign. No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect, which is consistent with the ClinVar “Uncertain” classification and does not contradict it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.370445Structured0.922652Binding0.3350.8650.250Uncertain 1-5.098Likely Benign0.378AmbiguousLikely Benign0.094Likely Benign-0.94Neutral0.985Probably Damaging0.950Probably Damaging4.11Benign0.06Tolerated3.6460.11410.465811-2.727.03
c.3359G>A
G1120D
2D
AIThe SynGAP1 missense variant G1120D is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33443911‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) resolves to a benign majority (2 benign vs. 1 pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.871313Disordered0.804931Binding0.3350.9250.8756-33443911-G-A42.65e-6-9.244Likely Pathogenic0.378AmbiguousLikely Benign0.351Likely Benign-0.82Neutral0.666Possibly Damaging0.355Benign3.60Benign0.19Tolerated3.7750.16590.1835-11-3.158.04
c.3434A>T
N1145I
2D
AIThe SynGAP1 missense variant N1145I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools cluster into two groups: pathogenic predictions come from REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; benign predictions come from ESM1b, FATHMM, and AlphaMissense‑Optimized. AlphaMissense‑Default is uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign, while Foldetta results are unavailable. Overall, the majority of conventional predictors indicate pathogenicity, whereas the high‑accuracy subset leans benign. Based on the aggregate evidence, the variant is most likely pathogenic, and this assessment does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.922952Disordered0.722723Binding0.2840.8501.000-3.172Likely Benign0.378AmbiguousLikely Benign0.504Likely Pathogenic-4.19Deleterious0.999Probably Damaging0.998Probably Damaging5.41Benign0.00Affected0.07200.6145-2-38.0-0.94
c.346T>C
Y116H
2D
AIThe SynGAP1 missense variant Y116H is listed in gnomAD (ID 6‑33432211‑T‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all indicate benign or likely benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments confirm the benign trend: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus also reports it as likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status, as none is currently assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.661982Disordered0.670235Binding0.3810.8780.6256-33432211-T-C74.34e-6-1.512Likely Benign0.378AmbiguousLikely Benign0.080Likely Benign0.11Neutral0.539Possibly Damaging0.085Benign4.21Benign0.40Tolerated3.6150.26910.048520-1.9-26.03
c.1498C>G
L500V
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant L500V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on benign effect include SIFT and AlphaMissense‑Optimized, whereas a majority of tools predict pathogenicity: SGM‑Consensus, REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. Predictions that are inconclusive are FoldX, Rosetta, Foldetta, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) as uncertain. Overall, the preponderance of evidence from multiple independent predictors indicates that the variant is most likely pathogenic, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.066181Structured0.382942Uncertain0.8930.1500.000-12.963Likely Pathogenic0.379AmbiguousLikely Benign1.92Ambiguous0.00.81Ambiguous1.37Ambiguous1.11Destabilizing0.565Likely Pathogenic-2.98Deleterious0.998Probably Damaging0.992Probably Damaging-1.24Pathogenic0.11Tolerated0.12050.1860210.4-14.03
c.2165G>A
S722N
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S722N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that reach consensus classify the change as benign: REVEL, FoldX, Rosetta, Foldetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict a neutral effect. No tool predicts pathogenicity; the only inconclusive results come from premPS and AlphaMissense‑Default, which are treated as unavailable evidence. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports a benign outcome, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates “Likely Benign,” and Foldetta (combining FoldX‑MD and Rosetta outputs) also predicts a benign impact. Taken together, the evidence overwhelmingly supports a benign classification, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.468512Structured0.457186Uncertain0.9500.4310.375-4.399Likely Benign0.379AmbiguousLikely Benign0.18Likely Benign0.10.15Likely Benign0.17Likely Benign0.79Ambiguous0.051Likely Benign-0.91Neutral0.072Benign0.028Benign2.58Benign0.27Tolerated0.12580.345211-2.727.03
c.3169A>C
S1057R
2D
AIThe SynGAP1 missense variant S1057R is catalogued in gnomAD (ID 6‑33443721‑A‑C) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.8756-33443721-A-C-6.648Likely Benign0.379AmbiguousLikely Benign0.221Likely Benign-0.24Neutral0.677Possibly Damaging0.168Benign5.30Benign0.21Tolerated3.7750.15840.3620-10-3.769.11
c.3171C>A
S1057R
2D
AIThe SynGAP1 missense variant S1057R is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign. Only polyPhen‑2 HumDiv flags it as pathogenic, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.875-6.648Likely Benign0.379AmbiguousLikely Benign0.272Likely Benign-0.24Neutral0.677Possibly Damaging0.168Benign5.30Benign0.21Tolerated3.7750.15840.3620-10-3.769.11
c.3171C>G
S1057R
2D
AIThe SynGAP1 missense variant S1057R is catalogued in gnomAD (ID 6‑33443723‑C‑G) but has no ClinVar submission. Functional prediction tools largely converge on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all report benign or tolerated. Only polyPhen‑2 HumDiv flags it as pathogenic, while AlphaMissense‑Default remains uncertain. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM Consensus confirms a benign likelihood; Foldetta data are unavailable, so no stability evidence is provided. Taken together, the preponderance of evidence indicates the variant is most likely benign, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.988291Disordered0.869507Binding0.4130.9270.8756-33443723-C-G-6.648Likely Benign0.379AmbiguousLikely Benign0.272Likely Benign-0.24Neutral0.677Possibly Damaging0.168Benign5.30Benign0.21Tolerated3.7750.15840.3620-10-3.769.11
c.3413C>T
S1138F
2D
AIThe SynGAP1 missense variant S1138F is not reported in ClinVar and is present in gnomAD (ID 6‑33444448‑C‑T). Functional prediction tools cluster into two groups: benign predictions come from REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from PROVEAN, polyPhen‑2 (HumDiv and HumVar), and SIFT. The high‑accuracy AlphaMissense‑Optimized score is benign. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default (uncertain), ESM1b (benign), FATHMM (benign), and PROVEAN (pathogenic), resolves to benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates a benign effect. This conclusion is consistent with the absence of a ClinVar classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.891961Disordered0.738250Binding0.3460.8691.0006-33444448-C-T16.20e-7-6.298Likely Benign0.379AmbiguousLikely Benign0.407Likely Benign-2.88Deleterious0.997Probably Damaging0.996Probably Damaging5.42Benign0.03Affected4.3240.09910.5623-2-33.660.10
c.3700C>A
L1234M
2D
AIThe SynGAP1 L1234M missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, ESM1b, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the balance of evidence slightly favors a pathogenic interpretation (5 pathogenic vs 4 benign predictions). This conclusion does not contradict ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.599170Disordered0.575096Binding0.8440.5270.125-8.235Likely Pathogenic0.379AmbiguousLikely Benign0.126Likely Benign-0.99Neutral0.898Possibly Damaging0.354Benign1.50Pathogenic0.03Affected0.06480.294442-1.918.03
c.3770C>T
S1257F
2D
AIThe SynGAP1 missense variant S1257F is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors a benign outcome. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing clinical database.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.541878Disordered0.482380Uncertain0.8890.5720.375-8.584Likely Pathogenic0.379AmbiguousLikely Benign0.141Likely Benign-2.41Neutral0.966Probably Damaging0.837Possibly Damaging2.55Benign0.08Tolerated0.04530.4747-3-23.660.10
c.1348G>A
A450T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 A450T missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. The remaining tools (FoldX, Rosetta, Foldetta, premPS, AlphaMissense‑Default) give uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Because the majority of conventional tools lean toward benign and no ClinVar evidence contradicts this, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.321458Structured0.306281Uncertain0.9630.2340.000-9.149Likely Pathogenic0.380AmbiguousLikely Benign0.50Ambiguous0.20.98Ambiguous0.74Ambiguous0.81Ambiguous0.233Likely Benign-3.35Deleterious0.996Probably Damaging0.973Probably Damaging3.40Benign0.06Tolerated0.09430.590210-2.530.03
c.2161A>G
I721V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I721V is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Predictions that are uncertain or inconclusive are FoldX, Rosetta, Foldetta, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as benign, while Foldetta (combining FoldX‑MD and Rosetta outputs) remains uncertain. Overall, the majority of reliable predictors classify the variant as benign, and this conclusion does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.394753Structured0.454550Uncertain0.9570.4370.125-6.730Likely Benign0.380AmbiguousLikely Benign1.22Ambiguous0.01.11Ambiguous1.17Ambiguous0.48Likely Benign0.098Likely Benign-0.40Neutral0.969Probably Damaging0.960Probably Damaging2.60Benign0.45Tolerated0.09760.307043-0.3-14.03
c.2276T>C
M759T
2D
AIThe SynGAP1 missense variant M759T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also reports a benign prediction. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence—including the SGM consensus and AlphaMissense‑Optimized—supports a benign classification, and this conclusion does not contradict the ClinVar status, which is currently unreported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.525368Disordered0.879389Binding0.2990.8640.375-4.202Likely Benign0.380AmbiguousLikely Benign0.197Likely Benign-1.90Neutral0.891Possibly Damaging0.315Benign2.58Benign0.08Tolerated0.20630.1534-1-1-2.6-30.09
c.2304C>A
D768E
2D
AIThe SynGAP1 missense variant D768E is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all classify the change as benign, and AlphaMissense‑Optimized also predicts a benign outcome. No tool predicts pathogenicity; AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the computational evidence strongly supports a benign effect for D768E, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.332115Structured0.928237Binding0.3140.8770.250-4.611Likely Benign0.380AmbiguousLikely Benign0.065Likely Benign-1.23Neutral0.393Benign0.171Benign4.16Benign0.17Tolerated0.13680.7729320.014.03
c.2304C>G
D768E
2D
AIThe SynGAP1 missense variant D768E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the computational evidence strongly suggests that D768E is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.332115Structured0.928237Binding0.3140.8770.250-4.611Likely Benign0.380AmbiguousLikely Benign0.065Likely Benign-1.23Neutral0.393Benign0.171Benign4.16Benign0.17Tolerated0.13680.7729320.014.03
c.2326G>T
G776C
2D
AIThe SynGAP1 missense variant G776C is not reported in ClinVar but is present in gnomAD (ID 6‑33442484‑G‑T). Prediction tools cluster into benign (REVEL, FATHMM, AlphaMissense‑Optimized) and pathogenic (PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT). Two tools (ESM1b, AlphaMissense‑Default) return uncertain results. High‑accuracy assessments are limited: AlphaMissense‑Optimized predicts benign, while the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive, and Foldetta data are unavailable. Overall, the majority of conventional predictors indicate pathogenicity, whereas the single high‑accuracy tool suggests benign. Given the preponderance of pathogenic predictions and the absence of a ClinVar entry, the variant is most likely pathogenic and does not contradict any existing ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.377384Structured0.886983Binding0.2960.8880.2506-33442484-G-T-7.974In-Between0.380AmbiguousLikely Benign0.181Likely Benign-2.59Deleterious1.000Probably Damaging0.998Probably Damaging4.15Benign0.01Affected3.6460.12350.4403-3-32.946.09
c.2758C>A
Q920K
2D
AIThe SynGAP1 missense variant Q920K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for Q920K, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.699094Disordered0.927260Binding0.3060.8450.250-4.234Likely Benign0.380AmbiguousLikely Benign0.145Likely Benign-1.72Neutral0.771Possibly Damaging0.412Benign2.67Benign0.00Affected0.20410.433111-0.40.04
c.1441C>A
H481N
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 H481N missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Two tools—Rosetta and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the lack of ClinVar annotation. Thus, the variant is most likely benign based on current predictive data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.257454Structured0.430977Uncertain0.7640.2470.000-8.229Likely Pathogenic0.381AmbiguousLikely Benign0.16Likely Benign0.10.54Ambiguous0.35Likely Benign0.09Likely Benign0.205Likely Benign-4.11Deleterious1.000Probably Damaging0.999Probably Damaging3.68Benign0.57Tolerated0.12050.163121-0.3-23.04
c.153C>G
I51M
2D
AIThe SynGAP1 missense variant I51M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic call comes from SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as likely benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, SGM‑Consensus indicates likely benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Based on the collective predictions, the I51M substitution is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.291804Structured0.454181Uncertain0.6060.7100.000-4.732Likely Benign0.381AmbiguousLikely Benign0.093Likely Benign-0.27Neutral0.099Benign0.075Benign4.13Benign0.00Affected0.07640.328121-2.618.03
c.2261A>C
E754A
2D
AIThe SynGAP1 missense variant E754A is not reported in ClinVar (ClinVar status: not reported) and is absent from gnomAD (gnomAD: not present). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv and FATHMM, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction (2 benign vs. 1 pathogenic votes). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.505461Disordered0.750531Binding0.3570.8720.500-4.688Likely Benign0.381AmbiguousLikely Benign0.049Likely Benign-1.56Neutral0.801Possibly Damaging0.412Benign2.49Pathogenic0.31Tolerated0.35490.62830-15.3-58.04
c.2504T>G
L835R
2D
AIThe SynGAP1 missense variant L835R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic outcome. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized independently predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.608892Disordered0.642742Binding0.3190.8630.125-4.749Likely Benign0.381AmbiguousLikely Benign0.126Likely Benign-1.05Neutral0.996Probably Damaging0.955Probably Damaging2.70Benign0.02Affected0.12390.0804-3-2-8.343.03
c.3222G>C
Q1074H
2D
AIThe SynGAP1 missense variant Q1074H is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools uniformly favor a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity, and the only uncertain call comes from AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports the variant as “Likely Benign.” High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.987006Binding0.3390.8970.750-5.051Likely Benign0.381AmbiguousLikely Benign0.053Likely Benign-0.12Neutral0.006Benign0.008Benign2.67Benign0.07Tolerated0.14360.4407300.39.01
c.3222G>T
Q1074H
2D
AIThe SynGAP1 missense variant Q1074H is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools uniformly favor a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity, and the only uncertain call comes from AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports the variant as “Likely Benign.” High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.987006Binding0.3390.8970.750-5.051Likely Benign0.381AmbiguousLikely Benign0.053Likely Benign-0.12Neutral0.006Benign0.008Benign2.67Benign0.07Tolerated0.14360.4407300.39.01
c.1526C>T
A509V
2D
3DClick to see structure in 3D Viewer
AISynGAP1 A509V is not reported in ClinVar and is absent from gnomAD. High‑accuracy predictors give mixed results: AlphaMissense‑Optimized classifies the variant as benign, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—labels it pathogenic; Foldetta, which integrates FoldX‑MD and Rosetta outputs, is inconclusive because FoldX is uncertain and Rosetta is benign. Among the remaining tools, benign predictions come from REVEL, Rosetta, premPS, polyPhen2_HumDiv, polyPhen2_HumVar, and SIFT, whereas pathogenic predictions come from SGM‑Consensus, PROVEAN, ESM1b, and FATHMM. AlphaMissense‑Default and FoldX remain uncertain. Overall, the majority of evidence points toward a benign effect, and this assessment does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.025762Structured0.250110Uncertain0.9230.2560.000-11.987Likely Pathogenic0.382AmbiguousLikely Benign0.52Ambiguous0.50.35Likely Benign0.44Likely Benign-0.25Likely Benign0.474Likely Benign-3.11Deleterious0.064Benign0.048Benign-1.15Pathogenic0.18Tolerated0.13330.5706002.428.05
c.3697A>C
I1233L
2D
AIThe SynGAP1 missense variant I1233L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, PolyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all score the substitution as benign, and AlphaMissense‑Optimized also predicts a benign outcome. No tool predicts pathogenicity; AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as likely benign. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus also indicates likely benign; Foldetta data are not available. Overall, the consensus of available predictions points to a benign effect, and this is consistent with the lack of ClinVar evidence or gnomAD observation. Thus, the variant is most likely benign, and this conclusion does not contradict ClinVar status, which has no entry for it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.525368Disordered0.564054Binding0.8810.5310.125-3.031Likely Benign0.382AmbiguousLikely Benign0.113Likely Benign-0.01Neutral0.211Benign0.108Benign2.95Benign1.00Tolerated0.06310.324622-0.70.00
c.136C>A
P46T
2D
AIThe SynGAP1 missense variant P46T is reported in ClinVar as “Not submitted” and is not present in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, all of which classify the change as benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT uniformly predict a pathogenic impact. AlphaMissense‑Default remains uncertain, and no Foldetta stability assessment is available. High‑accuracy methods give a consistent benign signal: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports “Likely Benign,” and Foldetta data are missing. Overall, the majority of reliable predictors and the consensus analysis indicate that P46T is most likely benign, and this conclusion does not contradict the ClinVar status, which contains no pathogenic assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.390993Structured0.433588Uncertain0.5490.7410.375-4.329Likely Benign0.383AmbiguousLikely Benign0.092Likely Benign-0.68Neutral0.909Possibly Damaging0.901Possibly Damaging4.13Benign0.00Affected0.21940.64000-10.93.99
c.150C>G
I50M
2D
AIThe SynGAP1 missense variant I50M is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from multiple prediction algorithms and high‑accuracy tools indicates that the I50M variant is most likely benign, and this conclusion does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.295083Structured0.449965Uncertain0.5450.7080.000-5.707Likely Benign0.383AmbiguousLikely Benign0.030Likely Benign-0.95Neutral0.637Possibly Damaging0.202Benign3.76Benign0.00Affected0.06030.252421-2.618.03
c.2027G>T
S676I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S676I is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and ESM1b. FoldX, Rosetta, Foldetta, and AlphaMissense‑Default are inconclusive. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction, while Foldetta remains uncertain. Overall, the balance of evidence (five benign versus three pathogenic predictions) indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.209395Structured0.113632Uncertain0.5510.3380.125-10.165Likely Pathogenic0.383AmbiguousLikely Benign1.25Ambiguous0.31.12Ambiguous1.19Ambiguous0.14Likely Benign0.170Likely Benign-2.46Neutral0.801Possibly Damaging0.063Benign3.38Benign0.02Affected0.08790.5720-1-25.326.08
c.2545G>T
D849Y
2D
AIThe SynGAP1 missense variant D849Y has no ClinVar entry and is not reported in gnomAD. Consensus from multiple in‑silico predictors shows a split: benign calls come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic calls arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default remains uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” status. High‑accuracy tools further support a benign interpretation: AlphaMissense‑Optimized predicts benign, SGM‑Consensus is likely benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Taken together, the majority of reliable predictors and consensus analyses indicate a benign effect. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with existing clinical evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.712013Disordered0.554191Binding0.3190.8130.500-6.200Likely Benign0.383AmbiguousLikely Benign0.150Likely Benign-1.92Neutral0.971Probably Damaging0.773Possibly Damaging4.13Benign0.00Affected0.07670.7690-4-32.248.09
c.3154G>A
G1052R
2D
AISynGAP1 missense variant G1052R is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Functional prediction tools cluster into two groups: benign predictions from REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized scores the variant as benign, and the SGM consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of evidence points to a benign effect, which does not contradict the ClinVar uncertain status but provides additional support toward a likely benign classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.984420Disordered0.892068Binding0.3670.9380.875Uncertain 1-9.050Likely Pathogenic0.383AmbiguousLikely Benign0.497Likely Benign-0.41Neutral0.990Probably Damaging0.798Possibly Damaging3.90Benign0.10Tolerated3.7750.09760.4142-2-3-4.199.14
c.3154G>C
G1052R
2D
AIThe SynGAP1 missense variant G1052R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and ESM1b predict a pathogenic outcome; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.984420Disordered0.892068Binding0.3670.9380.875-9.050Likely Pathogenic0.383AmbiguousLikely Benign0.497Likely Benign-0.41Neutral0.990Probably Damaging0.798Possibly Damaging3.90Benign0.10Tolerated3.7750.09760.4142-2-3-4.199.14
c.3274T>A
L1092M
2D
AIThe SynGAP1 missense variant L1092M is not reported in ClinVar and has no entries in gnomAD, indicating it has not been catalogued in these databases. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the substitution as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default tool remains uncertain, and no Foldetta stability assessment is available. High‑accuracy predictions from AlphaMissense‑Optimized and the SGM‑Consensus both support a benign outcome, whereas the absence of a Foldetta result precludes a stability‑based conclusion. Overall, the majority of evidence points to a benign effect for the variant, and this assessment does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.924947Disordered0.985431Binding0.3850.8901.000-5.348Likely Benign0.383AmbiguousLikely Benign0.083Likely Benign-0.15Neutral0.986Probably Damaging0.875Possibly Damaging2.66Benign0.21Tolerated0.09190.447942-1.918.03
c.3890G>T
R1297M
2D
AIThe SynGAP1 missense variant R1297M is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a pathogenic impact. This conclusion is not contradicted by ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.859585Disordered0.895222Binding0.5110.8170.625-4.286Likely Benign0.383AmbiguousLikely Benign0.139Likely Benign-3.00Deleterious0.938Possibly Damaging0.690Possibly Damaging2.45Pathogenic0.02Affected0.12940.24490-16.4-24.99
c.1469C>G
A490G
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A490G is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include only AlphaMissense‑Optimized. Those that predict a pathogenic effect comprise REVEL, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and the SGM‑Consensus (Likely Pathogenic). Predictions that are uncertain or inconclusive are FoldX, Foldetta, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the majority of evidence points to a pathogenic impact for A490G. This conclusion does not contradict ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.120615Structured0.322979Uncertain0.9380.2100.125-9.767Likely Pathogenic0.384AmbiguousLikely Benign1.24Ambiguous0.02.00Destabilizing1.62Ambiguous1.13Destabilizing0.744Likely Pathogenic-3.44Deleterious0.999Probably Damaging0.995Probably Damaging-1.46Pathogenic0.01Affected0.20510.222810-2.2-14.03
c.2336G>A
S779N
2D
AIThe SynGAP1 missense variant S779N is listed in gnomAD (ID 6‑33442494‑G‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. A high‑accuracy consensus (SGM Consensus) derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN yields a benign majority. The AlphaMissense‑Optimized score is benign, and no Foldetta stability assessment is available. Taken together, the majority of evidence points to a benign impact. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.509769Disordered0.834974Binding0.3210.8900.3756-33442494-G-A-4.880Likely Benign0.384AmbiguousLikely Benign0.087Likely Benign-0.75Neutral0.021Benign0.026Benign2.30Pathogenic0.23Tolerated3.6460.13270.498411-2.727.03
c.2420A>C
Y807S
2D
AIThe SynGAP1 Y807S variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on benign impact include REVEL, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b, while those that predict pathogenicity are PROVEAN, SIFT, and FATHMM. AlphaMissense‑Default is uncertain, whereas AlphaMissense‑Optimized predicts benign. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, leans toward pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of conventional tools (four benign vs. three pathogenic) suggest a benign effect, and the high‑accuracy AlphaMissense‑Optimized also predicts benign, while the SGM Consensus predicts pathogenic. Based on the balance of evidence, the variant is most likely benign, and this assessment does not contradict the lack of ClinVar reporting.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.699094Disordered0.853760Binding0.3360.9010.500-5.517Likely Benign0.384AmbiguousLikely Benign0.093Likely Benign-3.90Deleterious0.136Benign0.067Benign2.44Pathogenic0.01Affected0.45610.1884-3-20.5-76.10
c.2920G>T
D974Y
2D
AIThe SynGAP1 missense variant D974Y is not reported in ClinVar and has no entries in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the majority of computational evidence points to a benign impact, which is consistent with the absence of ClinVar pathogenic classification and gnomAD observations. Thus, the variant is most likely benign, and this assessment does not contradict any existing ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.964377Binding0.3890.8970.625-4.290Likely Benign0.384AmbiguousLikely Benign0.130Likely Benign-1.85Neutral0.716Possibly Damaging0.284Benign4.13Benign0.01Affected0.10720.6627-4-32.248.09
c.475A>G
I159V
2D
AIThe SynGAP1 I159V missense variant is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign consensus (2 benign vs. 1 pathogenic, with one uncertain). Foldetta results are unavailable. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.454136Structured0.529953Binding0.2780.7310.125-9.714Likely Pathogenic0.384AmbiguousLikely Benign0.113Likely Benign-0.25Neutral0.803Possibly Damaging0.847Possibly Damaging3.98Benign0.00Affected0.11110.273643-0.3-14.03
c.1231A>G
I411V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I411V is reported in ClinVar as benign (ClinVar ID 1654508.0) and is not found in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Two tools predict a pathogenic outcome: PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. Predictions that are inconclusive or unavailable are AlphaMissense‑Default, FoldX, Rosetta, premPS, and Foldetta. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta) is uncertain. Overall, the preponderance of evidence points to a benign effect for I411V, which is consistent with its ClinVar classification and does not contradict the reported status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.116183Structured0.339366Uncertain0.9270.1980.000Likely Benign 1-6.290Likely Benign0.385AmbiguousLikely Benign0.74Ambiguous0.00.82Ambiguous0.78Ambiguous0.99Ambiguous0.212Likely Benign-0.86Neutral0.935Possibly Damaging0.858Possibly Damaging3.90Benign0.27Tolerated3.38280.11120.352643-0.3-14.03233.328.2-0.20.0-0.20.0XPotentially BenignThe sec-butyl side chain of Ile411, located in the hydrophobic space between an anti-parallel β sheet strand (res. Pro398-Ile411) and an α helix (res. Asp684-Gln702), packs against multiple residues (e.g., Met409, Arg259). In the variant simulations, the side chain of Val411 is able to favorably fill the same hydrophobic niche despite its slightly smaller size. In short, the residue swap has no apparent negative effect on the structure based on the simulations.
c.137C>G
P46R
2D
AIThe SynGAP1 missense variant P46R is catalogued in gnomAD (ID 6‑33423546‑C‑G) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions come from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default is uncertain, and Foldetta (FoldX‑MD/Rosetta stability assessment) has no available result. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta data is missing. Overall, the majority of evidence points to a benign effect. There is no ClinVar status to contradict this conclusion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.390993Structured0.433588Uncertain0.5490.7410.3756-33423546-C-G16.20e-7-0.520Likely Benign0.385AmbiguousLikely Benign0.155Likely Benign0.39Neutral0.972Probably Damaging0.954Probably Damaging4.39Benign0.00Affected4.3210.16690.4543-20-2.959.07
c.2712G>A
M904I
2D
AIThe SynGAP1 missense variant M904I is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all return benign scores, and AlphaMissense‑Optimized also predicts a benign effect. No tool predicts pathogenicity, and the only uncertain result comes from AlphaMissense‑Default, which is inconclusive. The high‑accuracy consensus methods corroborate this benign assessment: the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign,” and AlphaMissense‑Optimized explicitly labels the variant as benign. Foldetta, a protein‑folding stability predictor, has no available result for this residue. Taken together, the evidence overwhelmingly supports a benign impact for M904I, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation. Thus, the variant is most likely benign, and this conclusion does not contradict the ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.589073Binding0.3500.9200.250-3.845Likely Benign0.385AmbiguousLikely Benign0.023Likely Benign-0.48Neutral0.039Benign0.023Benign2.78Benign0.07Tolerated0.16940.3633212.6-18.03
c.2712G>C
M904I
2D
AIThe SynGAP1 missense variant M904I is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all return benign scores, and AlphaMissense‑Optimized also predicts a benign effect. No tool predicts pathogenicity, and the only uncertain result comes from AlphaMissense‑Default, which is inconclusive. The high‑accuracy consensus methods corroborate this benign assessment: the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign,” and AlphaMissense‑Optimized also indicates a benign outcome. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Taken together, the evidence overwhelmingly supports a benign impact, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.589073Binding0.3500.9200.250-3.845Likely Benign0.385AmbiguousLikely Benign0.023Likely Benign-0.48Neutral0.039Benign0.023Benign2.78Benign0.07Tolerated0.16940.3633212.6-18.03
c.2712G>T
M904I
2D
AIThe SynGAP1 missense variant M904I is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Functional prediction tools uniformly classify the substitution as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all return benign scores, and AlphaMissense‑Optimized also predicts a benign effect. No tool predicts pathogenicity, and the only uncertain result comes from AlphaMissense‑Default, which is inconclusive. The high‑accuracy consensus methods corroborate this benign assessment: the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign,” and AlphaMissense‑Optimized also indicates a benign outcome. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Taken together, the evidence overwhelmingly supports a benign impact, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.589073Binding0.3500.9200.250-3.845Likely Benign0.385AmbiguousLikely Benign0.023Likely Benign-0.48Neutral0.039Benign0.023Benign2.78Benign0.07Tolerated0.16940.3633212.6-18.03
c.2810A>C
D937A
2D
AIThe SynGAP1 missense variant D937A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.819762Disordered0.963385Binding0.3480.8830.625-1.652Likely Benign0.385AmbiguousLikely Benign0.096Likely Benign-1.45Neutral0.995Probably Damaging0.895Possibly Damaging2.76Benign0.10Tolerated0.42960.72440-25.3-44.01
c.2940T>A
H980Q
2D
AIThe SynGAP1 missense variant H980Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for H980Q, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.974598Binding0.3090.8920.625-4.014Likely Benign0.385AmbiguousLikely Benign0.090Likely Benign-1.35Neutral0.802Possibly Damaging0.432Benign4.18Benign0.00Affected0.22360.393630-0.3-9.01
c.2940T>G
H980Q
2D
AIThe SynGAP1 missense variant H980Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for H980Q, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.974598Binding0.3090.8920.625-4.014Likely Benign0.385AmbiguousLikely Benign0.090Likely Benign-1.35Neutral0.802Possibly Damaging0.432Benign4.18Benign0.00Affected0.22360.393630-0.3-9.01
c.3395C>T
S1132F
2D
AIThe SynGAP1 missense variant S1132F is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from both general and high‑accuracy predictors indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.845506Binding0.2890.8940.750-5.458Likely Benign0.385AmbiguousLikely Benign0.310Likely Benign-2.02Neutral0.006Benign0.006Benign5.41Benign0.05Affected0.09210.5506-3-23.660.10
c.38T>C
I13T
2D
AIThe SynGAP1 missense variant I13T is listed in gnomAD (ID 6‑33420302‑T‑C) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign and the SGM‑Consensus is “Likely Benign.” No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.486429Structured0.482657Uncertain0.3180.9160.3756-33420302-T-C-2.856Likely Benign0.385AmbiguousLikely Benign0.132Likely Benign-0.02Neutral0.024Benign0.003Benign4.07Benign0.00Affected4.3210.14010.1778-10-5.2-12.05
c.461G>A
S154N
2D
AIThe SynGAP1 missense variant S154N is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools largely support a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports it as likely benign. Only one tool, polyPhen‑2 HumDiv, predicts a pathogenic outcome, and AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) likewise indicates likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar annotation or gnomAD observation. The variant is most likely benign based on predictions, and there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.505461Disordered0.508330Binding0.2840.7950.500-6.604Likely Benign0.385AmbiguousLikely Benign0.074Likely Benign-1.00Neutral0.900Possibly Damaging0.434Benign4.10Benign0.22Tolerated0.15450.429811-2.727.03
c.161A>C
N54T
2D
AIThe SynGAP1 missense variant N54T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence points to a benign impact, and this assessment does not contradict any ClinVar status, as no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.196879Structured0.464669Uncertain0.5040.6590.000-5.808Likely Benign0.386AmbiguousLikely Benign0.070Likely Benign-0.47Neutral0.659Possibly Damaging0.775Possibly Damaging4.20Benign0.00Affected0.12680.7498002.8-13.00
c.2933C>T
P978L
2D
AIThe SynGAP1 missense variant P978L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.819762Disordered0.975775Binding0.4250.8920.625-4.621Likely Benign0.386AmbiguousLikely Benign0.092Likely Benign-2.08Neutral0.818Possibly Damaging0.378Benign4.15Benign0.01Affected0.23260.6997-3-35.416.04
c.1040C>T
T347I
2D
3DClick to see structure in 3D Viewer
AISynGAP1 T347I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that provide definitive calls cluster into two groups: benign predictions come from REVEL, premPS, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Optimized; pathogenic predictions come from PROVEAN, polyPhen‑2 HumDiv, ESM1b, and FATHMM. Tools with inconclusive outputs (FoldX, Rosetta, Foldetta, AlphaMissense‑Default) are treated as unavailable. High‑accuracy assessments further split the evidence: AlphaMissense‑Optimized predicts benign, while the SGM consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—predicts pathogenic; Foldetta remains uncertain. Consequently, the variant’s pathogenicity is ambiguous, with an equal number of strong benign and pathogenic calls and no consensus from the most reliable methods. The variant is therefore most likely uncertain, and this assessment does not contradict any ClinVar status, as none is available.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicC20.268042Structured0.349915Uncertain0.9510.4340.000-10.148Likely Pathogenic0.387AmbiguousLikely Benign-0.79Ambiguous0.1-0.94Ambiguous-0.87Ambiguous0.29Likely Benign0.079Likely Benign-3.12Deleterious0.627Possibly Damaging0.139Benign1.70Pathogenic0.08Tolerated0.08850.62980-15.212.05
c.2270G>A
G757D
2D
AIThe SynGAP1 missense variant G757D is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign. Only polyPhen‑2 HumDiv flags it as pathogenic, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Taken together, the preponderance of evidence supports a benign interpretation, and this assessment does not contradict any ClinVar annotation (none is present). Therefore, the variant is most likely benign, with no conflict with ClinVar.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.436924Structured0.830995Binding0.3100.8690.375-4.613Likely Benign0.387AmbiguousLikely Benign0.150Likely Benign-0.90Neutral0.454Possibly Damaging0.192Benign2.71Benign0.11Tolerated0.18260.16111-1-3.158.04
c.2741A>C
D914A
2D
AIThe SynGAP1 missense variant D914A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for D914A, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.699094Disordered0.785987Binding0.3200.8920.250-1.690Likely Benign0.387AmbiguousLikely Benign0.128Likely Benign-1.48Neutral0.996Probably Damaging0.953Probably Damaging2.69Benign0.05Affected0.44130.70860-25.3-44.01
c.390A>C
Q130H
2D
AIThe SynGAP1 missense variant Q130H is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions come from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, indicates a likely benign effect. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts benign, SGM‑Consensus also predicts likely benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is assigned).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.509769Disordered0.718853Binding0.3060.8850.375-3.828Likely Benign0.387AmbiguousLikely Benign0.074Likely Benign-1.09Neutral0.990Probably Damaging0.969Probably Damaging4.10Benign0.01Affected0.17270.3970300.39.01
c.390A>T
Q130H
2D
AIThe SynGAP1 missense variant Q130H is not reported in ClinVar and has no entry in gnomAD. Consensus from multiple in‑silico predictors shows a predominance of benign calls: REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict a benign effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT each predict a pathogenic impact. The AlphaMissense‑Default tool remains uncertain, and no Foldetta stability assessment is available. High‑accuracy tools specifically highlight benign predictions: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and Foldetta data are missing. Overall, the balance of evidence points to a benign effect for the variant, and this assessment does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.509769Disordered0.718853Binding0.3060.8850.375-3.828Likely Benign0.387AmbiguousLikely Benign0.074Likely Benign-1.09Neutral0.990Probably Damaging0.969Probably Damaging4.10Benign0.01Affected0.17270.3970300.39.01
c.961C>T
R321C
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant R321C is listed in ClinVar with an “Uncertain” status and is present in gnomAD (variant ID 6‑33437866‑C‑T). Prediction tools that agree on a benign effect include REVEL, premPS, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. Five tools (SGM‑Consensus, FoldX, Rosetta, AlphaMissense‑Default, and Foldetta) report uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the majority of predictions (six out of eleven) support a pathogenic impact, while three support benign and five are inconclusive. Thus, the variant is most likely pathogenic based on current computational evidence, and this does not contradict its ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicC20.175930Structured0.423273Uncertain0.9310.2970.125Conflicting 26-33437866-C-T95.58e-6-10.025Likely Pathogenic0.387AmbiguousLikely Benign0.57Ambiguous0.10.56Ambiguous0.57Ambiguous0.18Likely Benign0.495Likely Benign-4.59Deleterious1.000Probably Damaging0.998Probably Damaging1.89Pathogenic0.01Affected3.38230.33130.2516-3-47.0-53.05
c.1136C>G
S379W
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S379W is listed in ClinVar with an uncertain significance and is present in gnomAD (ID 6‑33438041‑C‑G). Prediction tools that indicate a benign effect include premPS, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic impact comprise REVEL, FoldX, Rosetta, Foldetta, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as pathogenic, and the SGM Consensus as benign. Because the majority of conventional tools favor pathogenicity while the high‑accuracy subset is split, the overall evidence leans toward a pathogenic effect. This conclusion does not contradict the ClinVar uncertain status, which remains unresolved.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.728858Disordered0.433206Uncertain0.3270.9310.625Uncertain 16-33438041-C-G-8.898Likely Pathogenic0.388AmbiguousLikely Benign4.32Destabilizing3.43.56Destabilizing3.94Destabilizing0.16Likely Benign0.520Likely Pathogenic-1.02Neutral0.998Probably Damaging0.844Possibly Damaging3.82Benign0.01Affected4.32110.11960.6070-2-3-0.199.14271.3-75.71.41.00.60.5UncertainSer379 is located in the Gly-rich Ω loop (res. Pro364-Pro398) between two anti-parallel β sheet strands (res. Thr359-Pro364, res. Ala399-Ile411). Because the Ω loop is assumed to directly interact with the membrane, it moves arbitrarily throughout the WT solvent simulations. The Ω loop potentially plays a crucial role in the SynGAP-membrane complex association, stability, and dynamics. However, this aspect cannot be fully addressed through solvent simulations alone.Ω loops are known to play major roles in protein functions that require flexibility, and thus hydrophobic residues like tryptophan are rarely tolerated. Although no major negative structural effects are observed in the variant simulations, Trp379 may exert drastic effects on the SynGAP-membrane complex dynamics and stability. However, since the effect on Gly-rich Ω loop dynamics can only be studied through the SynGAP-membrane complex, no definite conclusions can be drawn
c.2300T>G
I767S
2D
AIThe SynGAP1 missense variant I767S is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign. Only polyPhen‑2 HumDiv flags it as pathogenic, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign outcome. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates likely benign; Foldetta results are not available. Taken together, the preponderance of evidence points to a benign classification for I767S, and this assessment does not conflict with the absence of a ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.321458Structured0.927771Binding0.3690.8720.125-3.030Likely Benign0.388AmbiguousLikely Benign0.126Likely Benign-0.64Neutral0.925Possibly Damaging0.329Benign4.13Benign0.25Tolerated0.32420.1782-1-2-5.3-26.08
c.2354G>A
R785H
2D
AIThe SynGAP1 R785H missense variant (ClinVar ID 2321588.0) is listed as “Uncertain” in ClinVar and is present in gnomAD (ID 6‑33442906‑G‑A). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized, while those that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, whereas the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a pathogenic outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, does not provide a result for this variant. Overall, the majority of computational predictions (five pathogenic versus three benign) lean toward a pathogenic interpretation. Thus, the variant is most likely pathogenic based on current predictions, and this conclusion does not contradict the ClinVar status, which remains uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.859585Disordered0.681730Binding0.3250.8960.625Uncertain 26-33442906-G-A42.50e-6-4.782Likely Benign0.388AmbiguousLikely Benign0.129Likely Benign-2.61Deleterious0.999Probably Damaging0.947Probably Damaging2.25Pathogenic0.01Affected3.6460.32600.1589201.3-19.05
c.3305C>A
A1102D
2D
AIThe SynGAP1 missense variant A1102D is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently contains no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.915074Disordered0.962659Binding0.3880.8590.875-4.647Likely Benign0.388AmbiguousLikely Benign0.081Likely Benign-1.38Neutral0.033Benign0.028Benign2.27Pathogenic0.12Tolerated0.20450.29840-2-5.344.01
c.896G>A
R299H
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant R299H is listed in ClinVar with an uncertain significance and is present in gnomAD (ID 6‑33437801‑G‑A). Functional prediction tools cluster into two groups: benign predictions from REVEL and AlphaMissense‑Optimized, and pathogenic predictions from FoldX, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; Rosetta, ESM1b, and AlphaMissense‑Default are inconclusive. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as pathogenic, and the SGM consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a tie between pathogenic and uncertain calls. Overall, the majority of evidence points to a pathogenic effect, which is consistent with the ClinVar uncertain designation rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.321458Structured0.262979Uncertain0.8190.2950.500Conflicting 26-33437801-G-A106.20e-6-7.731In-Between0.388AmbiguousLikely Benign3.97Destabilizing1.00.94Ambiguous2.46Destabilizing1.41Destabilizing0.238Likely Benign-3.35Deleterious1.000Probably Damaging0.998Probably Damaging1.69Pathogenic0.02Affected3.39190.32930.2982201.3-19.05211.272.5-0.10.2-0.20.3XPotentially PathogenicThe guanidinium group of Arg299, located in a β hairpin loop linking two anti-parallel β sheet strands (res. Met289-Pro298, res. Thr305-Asn315), forms hydrogen bonds that stabilize the tight turn. In the WT simulations, the Arg299 side chain hydrogen bonds with the loop backbone carbonyl groups (e.g., Ser302, Thr305, Leu274, Gly303), the hydroxyl group of Ser300, and even forms a salt bridge with the carboxylate group of Asp304.In the variant simulations, the imidazole ring of His299 (epsilon protonated state) hydrogen bonds with the carbonyl group of Asp304 and the hydroxyl group of Ser300. However, it does not form as many or as strong interactions as arginine, which could affect the initial formation of the secondary hairpin loop during folding. β hairpins are potential nucleation sites during the initial stages of protein folding, so even minor changes in them could be significant.Additionally, His299 prefers to hydrophobically interact with other hydrophobic residues inside the C2 domain core (e.g., Val306, Leu274), which destabilizes the C2 domain. Indeed, the β strand partially unfolds during the second simulation. Moreover, the positively charged Arg299 side chain faces the polar head group region of the inner leaflet membrane and could directly anchor the C2 domain to the membrane. In short, the residue swap could negatively affect both protein folding and the stability of the SynGAP-membrane association.
c.1828C>A
L610I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L610I is listed in gnomAD (ID 6‑33440880‑C‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized, while pathogenic predictions arise from REVEL, polyPhen‑2 (HumDiv and HumVar) and FATHMM. Four tools are uncertain (FoldX, Foldetta, premPS, AlphaMissense‑Default). High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized scores benign, the SGM consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors benign, whereas Foldetta’s stability estimate is unavailable. Overall, the balance of evidence points to a benign effect for L610I, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.271506Structured0.209504Uncertain0.8880.2530.0006-33440880-C-A16.19e-7-6.362Likely Benign0.389AmbiguousLikely Benign1.50Ambiguous0.20.18Likely Benign0.84Ambiguous0.76Ambiguous0.544Likely Pathogenic-1.86Neutral0.992Probably Damaging0.997Probably Damaging-1.34Pathogenic0.15Tolerated3.37350.09990.3219220.70.00
c.1993T>C
Y665H
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Y665H is not reported in ClinVar (ClinVar status: not reported) but is present in gnomAD (gnomAD ID: 6‑33441252‑T‑C). Prediction tools that agree on a benign effect include REVEL, Rosetta, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are premPS, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Tools with uncertain or inconclusive results are FoldX, Foldetta, and AlphaMissense‑Default. High‑accuracy methods give a benign consensus: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign, and Foldetta remains uncertain. Overall, the majority of predictions (7 benign vs. 4 pathogenic) and the high‑accuracy consensus support a benign classification. This conclusion does not contradict the ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.098513Structured0.086641Uncertain0.9220.3610.0006-33441252-T-C21.24e-6-9.303Likely Pathogenic0.389AmbiguousLikely Benign0.85Ambiguous0.00.28Likely Benign0.57Ambiguous1.12Destabilizing0.129Likely Benign-2.00Neutral1.000Probably Damaging0.996Probably Damaging3.45Benign0.48Tolerated3.38280.21220.051320-1.9-26.03
c.2669G>T
R890L
2D
AIThe SynGAP1 missense variant R890L is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a benign prediction (2 benign vs. 1 pathogenic, with one uncertain). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of high‑accuracy and consensus predictions indicate a benign impact. This conclusion is not contradicted by ClinVar status, which has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.720929Disordered0.531156Binding0.2840.9280.625-2.387Likely Benign0.389AmbiguousLikely Benign0.213Likely Benign-2.74Deleterious0.990Probably Damaging0.921Probably Damaging3.98Benign0.20Tolerated0.18760.3406-3-28.3-43.03
c.3112A>C
T1038P
2D
AIThe SynGAP1 missense variant T1038P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (both HumDiv and HumVar) predict a pathogenic outcome. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.982911Binding0.2790.7940.625-2.196Likely Benign0.390AmbiguousLikely Benign0.116Likely Benign-1.10Neutral0.965Probably Damaging0.611Possibly Damaging2.66Benign0.26Tolerated0.18560.46800-1-0.9-3.99
c.3113C>A
T1038N
2D
AIThe SynGAP1 missense variant T1038N is not reported in ClinVar and has no entries in gnomAD, indicating it has not been catalogued in these databases. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the substitution as benign, while the majority‑vote consensus from SGM (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, and AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates likely benign. No Foldetta stability analysis is available, so folding‑stability evidence is lacking. Overall, the preponderance of computational evidence supports a benign classification for T1038N, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation. Thus, the variant is most likely benign, and this is not contradicted by ClinVar, which has no pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.938133Disordered0.982911Binding0.2790.7940.625-3.837Likely Benign0.390AmbiguousLikely Benign0.054Likely Benign-1.36Neutral0.818Possibly Damaging0.355Benign2.68Benign0.10Tolerated0.11840.449000-2.813.00
c.3166G>C
G1056R
2D
AIThe SynGAP1 missense variant G1056R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are ESM1b and FATHMM, while AlphaMissense‑Default remains uncertain. High‑accuracy assessment shows AlphaMissense‑Optimized as benign, the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) favors a pathogenic outcome, and Foldetta data are unavailable. Overall, the majority of conventional predictors indicate a benign impact, whereas the SGM Consensus suggests pathogenicity. Given the preponderance of benign predictions and the lack of ClinVar evidence, the variant is most likely benign, and this assessment does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.988291Disordered0.868632Binding0.4020.9350.875-9.358Likely Pathogenic0.390AmbiguousLikely Benign0.410Likely Benign0.12Neutral0.011Benign0.010Benign1.83Pathogenic0.13Tolerated0.11270.4533-3-2-4.199.14
c.3247A>C
K1083Q
2D
AIThe SynGAP1 missense variant K1083Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions come from polyPhen‑2 HumDiv and HumVar. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign effect. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also reports likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from both general and high‑accuracy tools points to a benign impact for K1083Q, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.837511Disordered0.978906Binding0.3020.8931.000-2.214Likely Benign0.390AmbiguousLikely Benign0.099Likely Benign-0.50Neutral0.999Probably Damaging0.995Probably Damaging4.06Benign0.37Tolerated0.48210.1647110.4-0.04
c.3869G>T
R1290M
2D
AIThe SynGAP1 missense variant R1290M is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of reliable predictions indicate a benign impact, and this conclusion does not contradict any ClinVar annotation because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.784345Disordered0.844138Binding0.5670.7950.625-4.661Likely Benign0.390AmbiguousLikely Benign0.143Likely Benign-3.47Deleterious0.977Probably Damaging0.796Possibly Damaging2.60Benign0.00Affected0.10590.28990-16.4-24.99
c.2160C>A
D720E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 D720E missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign majority, and Foldetta also predicts benign stability. No prediction or folding result is missing or inconclusive. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.374039Structured0.450695Uncertain0.9550.4170.125-5.527Likely Benign0.391AmbiguousLikely Benign-0.31Likely Benign0.1-0.41Likely Benign-0.36Likely Benign0.23Likely Benign0.131Likely Benign-2.46Neutral0.975Probably Damaging0.969Probably Damaging2.46Pathogenic0.15Tolerated0.13100.5275320.014.03
c.2160C>G
D720E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 D720E missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign majority, and Foldetta also predicts benign stability. No prediction or folding result is missing or inconclusive. Overall, the variant is most likely benign based on the collective predictions, and this assessment does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.374039Structured0.450695Uncertain0.9550.4170.125-5.527Likely Benign0.391AmbiguousLikely Benign-0.31Likely Benign0.1-0.41Likely Benign-0.36Likely Benign0.23Likely Benign0.131Likely Benign-2.46Neutral0.975Probably Damaging0.969Probably Damaging2.46Pathogenic0.15Tolerated0.13100.5275320.014.03
c.3173G>A
G1058D
2D
AIThe SynGAP1 missense variant G1058D is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33443725‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict ClinVar, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.980739Disordered0.885724Binding0.4070.9290.8756-33443725-G-A16.21e-7-10.344Likely Pathogenic0.391AmbiguousLikely Benign0.177Likely Benign-0.33Neutral0.077Benign0.042Benign5.20Benign0.01Affected3.7750.18890.2435-11-3.158.04
c.3187G>C
G1063R
2D
AIThe SynGAP1 missense variant G1063R is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the collective evidence strongly supports a benign classification, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975134Disordered0.945784Binding0.3940.9130.875-5.711Likely Benign0.391AmbiguousLikely Benign0.078Likely Benign0.55Neutral0.411Benign0.114Benign4.28Benign0.09Tolerated0.10370.5133-3-2-4.199.14
c.3877G>C
D1293H
2D
AIThe SynGAP1 missense variant D1293H is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicting benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) predicts pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of predictions (five pathogenic vs. three benign) and the SGM Consensus support a pathogenic classification, whereas AlphaMissense‑Optimized suggests benign. The variant is most likely pathogenic based on the collective evidence, and this conclusion does not contradict any ClinVar status because the variant is not yet reported there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.779859Disordered0.892346Binding0.5690.8010.625-4.422Likely Benign0.391AmbiguousLikely Benign0.278Likely Benign-4.59Deleterious0.984Probably Damaging0.888Possibly Damaging2.17Pathogenic0.00Affected0.16090.37311-10.322.05
c.595A>T
N199Y
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant N199Y is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Functional prediction tools cluster into two groups: benign predictions come from REVEL, FoldX, Rosetta, Foldetta, premPS, polyPhen‑2 (HumVar), FATHMM, and AlphaMissense‑Optimized; pathogenic predictions arise from SIFT, PROVEAN, polyPhen‑2 (HumDiv), and ESM1b. AlphaMissense‑Default remains uncertain. High‑accuracy assessments further refine the picture: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves as pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) indicates benign stability. Overall, the majority of conventional tools (8 benign vs. 4 pathogenic) favor a benign effect, and this interpretation does not conflict with the absence of ClinVar annotation. Therefore, the variant is most likely benign based on the current predictive evidence, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
PH0.390993Structured0.431347Uncertain0.5710.4730.125-8.575Likely Pathogenic0.391AmbiguousLikely Benign-0.06Likely Benign0.10.14Likely Benign0.04Likely Benign0.20Likely Benign0.097Likely Benign-3.12Deleterious0.952Possibly Damaging0.395Benign4.15Benign0.04Affected0.03890.5630-2-22.249.07
c.910G>A
D304N
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant D304N is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as pathogenic, and Foldetta as benign. Overall, the majority of evidence points to a benign impact, which does not contradict the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.352862Structured0.285053Uncertain0.7640.2710.250Uncertain 1-6.194Likely Benign0.391AmbiguousLikely Benign0.30Likely Benign0.1-0.08Likely Benign0.11Likely Benign0.21Likely Benign0.345Likely Benign-4.18Deleterious0.999Probably Damaging0.997Probably Damaging1.81Pathogenic0.03Affected3.38230.13530.7205120.0-0.98
c.1309C>G
P437A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 P437A missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that classify the variant as benign include REVEL, Rosetta, FATHMM, AlphaMissense‑Optimized, and premPS. Those that predict pathogenicity are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. Tools with uncertain or inconclusive results are AlphaMissense‑Default, FoldX, and Foldetta. High‑accuracy assessments give AlphaMissense‑Optimized a benign prediction. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default (uncertain), ESM1b (pathogenic), FATHMM (benign), and PROVEAN (pathogenic), yields a pathogenic consensus. Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, is uncertain. Overall, the balance of evidence leans toward a pathogenic effect for P437A, and this conclusion does not contradict the current ClinVar status, which has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.175930Structured0.306196Uncertain0.9210.2980.000-12.059Likely Pathogenic0.392AmbiguousLikely Benign1.23Ambiguous0.0-3.14Stabilizing-0.96Ambiguous0.50Likely Benign0.266Likely Benign-6.53Deleterious0.999Probably Damaging0.998Probably Damaging3.51Benign0.03Affected0.34890.47751-13.4-26.04
c.2678A>G
Q893R
2D
AIThe SynGAP1 missense variant Q893R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.447267Uncertain0.3100.9250.750-3.338Likely Benign0.392AmbiguousLikely Benign0.056Likely Benign-1.43Neutral0.802Possibly Damaging0.333Benign2.79Benign0.09Tolerated0.15650.241211-1.028.06
c.2747T>A
V916D
2D
AIThe SynGAP1 missense variant V916D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT uniformly predict a pathogenic outcome. AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus indicates Likely Benign, and Foldetta (which integrates FoldX‑MD and Rosetta outputs) is not available for this variant. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.642678Disordered0.835395Binding0.3080.8790.250-2.653Likely Benign0.392AmbiguousLikely Benign0.139Likely Benign-1.48Neutral0.975Probably Damaging0.767Possibly Damaging2.69Benign0.01Affected0.15800.1113-2-3-7.715.96
c.3395C>A
S1132Y
2D
AIThe SynGAP1 missense variant S1132Y is listed in ClinVar as a benign alteration (ClinVar ID 845357.0) and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence supports a benign classification, which aligns with the ClinVar status and does not contradict it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.845506Binding0.2890.8940.750Likely Benign 1-5.894Likely Benign0.392AmbiguousLikely Benign0.401Likely Benign-1.76Neutral0.500Possibly Damaging0.208Benign5.40Benign0.09Tolerated4.3240.08890.5233-3-2-0.576.10
c.3877G>T
D1293Y
2D
AIThe SynGAP1 missense variant D1293Y is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicting benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) predicts pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of predictions (five pathogenic vs. three benign) and the SGM Consensus support a pathogenic classification, with no ClinVar entry to contradict this assessment. Thus, the variant is most likely pathogenic.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.779859Disordered0.892346Binding0.5690.8010.625-5.452Likely Benign0.392AmbiguousLikely Benign0.310Likely Benign-6.15Deleterious0.995Probably Damaging0.897Possibly Damaging2.15Pathogenic0.00Affected0.06270.3577-4-32.248.09
c.3946A>T
N1316Y
2D
AIThe SynGAP1 missense variant N1316Y is reported in gnomAD (variant ID 6‑33451820‑A‑T) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, polyPhen2_HumVar, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions come from polyPhen2_HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar status (none is available). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.899122Disordered0.971970Binding0.3800.8850.7506-33451820-A-T-5.579Likely Benign0.392AmbiguousLikely Benign0.101Likely Benign-2.48Neutral0.939Possibly Damaging0.396Benign3.90Benign0.00Affected3.7750.06710.5365-2-22.249.07
c.121C>A
R41S
2D
AIThe SynGAP1 missense variant R41S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for R41S, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.311707Structured0.431757Uncertain0.3440.7650.375-3.367Likely Benign0.393AmbiguousLikely Benign0.130Likely Benign-0.22Neutral0.686Possibly Damaging0.735Possibly Damaging4.24Benign0.00Affected0.31900.50130-13.7-69.11
c.2277G>A
M759I
2D
AIThe SynGAP1 missense variant M759I is listed in ClinVar (ID 3686687.0) with an “Uncertain” status and is present in gnomAD (variant ID 6‑33441742‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this is consistent with the ClinVar “Uncertain” classification rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.525368Disordered0.879389Binding0.2990.8640.375Uncertain 16-33441742-G-A16.20e-7-4.058Likely Benign0.393AmbiguousLikely Benign0.075Likely Benign-0.88Neutral0.454Possibly Damaging0.192Benign2.83Benign0.34Tolerated3.9950.12350.3129122.6-18.03
c.2277G>C
M759I
2D
AIThe SynGAP1 missense variant M759I is catalogued in gnomAD (6‑33441742‑G‑C) and has no ClinVar entry. Consensus from multiple in‑silico predictors points to a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all score the variant as benign, while only polyPhen‑2 HumDiv flags it as pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as “Likely Benign.” High‑accuracy tools reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta results are not available, so they do not influence the assessment. Overall, the computational evidence overwhelmingly supports a benign classification, and this is consistent with the absence of a pathogenic ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.525368Disordered0.879389Binding0.2990.8640.3756-33441742-G-C-4.058Likely Benign0.393AmbiguousLikely Benign0.075Likely Benign-0.88Neutral0.454Possibly Damaging0.192Benign2.83Benign0.34Tolerated3.9950.12350.3129122.6-18.03
c.2277G>T
M759I
2D
AIThe SynGAP1 missense variant M759I is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status is unavailable. Overall, the preponderance of evidence from multiple prediction algorithms and high‑accuracy tools points to a benign impact for M759I, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.525368Disordered0.879389Binding0.2990.8640.375-4.058Likely Benign0.393AmbiguousLikely Benign0.075Likely Benign-0.88Neutral0.454Possibly Damaging0.192Benign2.83Benign0.34Tolerated3.9950.12350.3129122.6-18.03
c.2378A>C
K793T
2D
AIThe SynGAP1 missense variant K793T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also reports it as likely benign. Only SIFT predicts a pathogenic outcome, and AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) indicates likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for K793T, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.971072Disordered0.426071Uncertain0.3440.9010.875-3.861Likely Benign0.393AmbiguousLikely Benign0.066Likely Benign-1.47Neutral0.174Benign0.123Benign4.12Benign0.03Affected0.27560.34730-13.2-27.07
c.2762T>C
L921P
2D
AIThe SynGAP1 missense variant L921P is recorded in gnomAD (ID 6‑33443314‑T‑C) but has no ClinVar submission. Functional prediction tools cluster into two groups: benign calls from REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized; pathogenic calls from polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. AlphaMissense‑Default is uncertain. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive because the votes are split (two benign, one pathogenic, one uncertain). Foldetta, a protein‑folding stability predictor that combines FoldX‑MD and Rosetta outputs, has no reported result for this variant. Consequently, the evidence is evenly divided, with high‑accuracy tools not providing a decisive verdict. The variant is therefore inconclusive; it does not contradict ClinVar status, which currently has no entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.608892Disordered0.943282Binding0.3110.8450.3756-33443314-T-C16.20e-7-2.087Likely Benign0.393AmbiguousLikely Benign0.215Likely Benign-1.83Neutral0.998Probably Damaging0.958Probably Damaging2.39Pathogenic0.00Affected3.7750.35810.1343-3-3-5.4-16.04
c.3812A>G
E1271G
2D
AIThe SynGAP1 missense variant E1271G is catalogued in gnomAD (ID 6‑33447860‑A‑G) but has no entry in ClinVar. Functional prediction tools show a split consensus: benign calls come from REVEL, ESM1b, and AlphaMissense‑Optimized, while pathogenic calls are made by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further clarify the picture: AlphaMissense‑Optimized predicts a benign effect, whereas the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—leans pathogenic (two pathogenic versus one benign vote). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence, including the SGM Consensus, indicates a pathogenic impact. This prediction is not contradicted by ClinVar, as no ClinVar classification exists for E1271G.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.483068Structured0.767529Binding0.8320.6660.3756-33447860-A-G-4.857Likely Benign0.393AmbiguousLikely Benign0.288Likely Benign-5.37Deleterious0.905Possibly Damaging0.538Possibly Damaging2.05Pathogenic0.00Affected3.7750.25130.5485-203.1-72.0610.1016/j.ajhg.2020.11.011
c.3320A>G
Q1107R
2D
AIThe SynGAP1 missense variant Q1107R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. AlphaMissense‑Default is uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign.” AlphaMissense‑Optimized also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.951017Binding0.3930.8800.875-2.837Likely Benign0.394AmbiguousLikely Benign0.126Likely Benign-1.76Neutral0.965Probably Damaging0.425Benign2.55Benign0.04Affected0.14820.331911-1.028.06
c.1321G>C
V441L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V441L is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Optimized. Only ESM1b predicts a pathogenic outcome, while Rosetta and AlphaMissense‑Default are uncertain. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also predicts benign. No prediction or folding result is missing or inconclusive. Overall, the variant is most likely benign based on the preponderance of evidence, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.161087Structured0.259875Uncertain0.9180.2490.000-9.546Likely Pathogenic0.395AmbiguousLikely Benign-0.43Likely Benign0.00.59Ambiguous0.08Likely Benign0.45Likely Benign0.135Likely Benign-2.27Neutral0.165Benign0.028Benign3.43Benign0.11Tolerated0.09610.388121-0.414.03
c.2083C>A
L695I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L695I is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, PROVEAN, SIFT, and FATHMM, while polyPhen‑2 (HumDiv and HumVar) and ESM1b predict a pathogenic outcome. The remaining tools—AlphaMissense‑Default, Foldetta, premPS, and Rosetta—return uncertain results and are treated as unavailable evidence. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction, whereas Foldetta remains uncertain. Overall, the majority of reliable predictions support a benign classification, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.118441Structured0.373419Uncertain0.9420.2580.000-12.096Likely Pathogenic0.395AmbiguousLikely Benign0.47Likely Benign0.10.63Ambiguous0.55Ambiguous0.93Ambiguous0.251Likely Benign-2.00Neutral0.996Probably Damaging0.905Possibly Damaging3.24Benign0.08Tolerated0.08150.2759220.70.00
c.2681G>T
G894V
2D
AIThe SynGAP1 missense variant G894V is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also leans benign, and Foldetta results are unavailable. Overall, the majority of high‑confidence tools predict a benign impact, and there is no conflict with the ClinVar status. Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.788093Disordered0.425700Uncertain0.3100.9250.750-5.047Likely Benign0.395AmbiguousLikely Benign0.188Likely Benign-2.61Deleterious1.000Probably Damaging1.000Probably Damaging2.64Benign0.02Affected0.11870.4091-1-34.642.08
c.3856G>A
E1286K
2D
AIThe SynGAP1 missense variant E1286K is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33447904‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also predicts benign. Foldetta results are unavailable. Overall, the majority of evidence (5 benign vs. 3 pathogenic) supports a benign classification. This conclusion does not contradict ClinVar status, as the variant is not yet classified there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.852992Disordered0.817022Binding0.5440.7650.7506-33447904-G-A-3.784Likely Benign0.395AmbiguousLikely Benign0.195Likely Benign-2.36Neutral0.770Possibly Damaging0.242Benign2.47Pathogenic0.02Affected3.7750.20690.511710-0.4-0.94
c.503A>G
H168R
2D
AIThe SynGAP1 missense variant H168R is reported in gnomAD (ID 6‑33432800‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized all classify the change as benign, whereas SIFT predicts it to be pathogenic. Two tools (ESM1b and AlphaMissense‑Default) return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive because it contains two benign and two uncertain calls, and Foldetta data are not available. Overall, the preponderance of evidence points to a benign impact. This conclusion does not contradict ClinVar, which currently has no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.433034Structured0.502450Binding0.4020.6780.1256-33432800-A-G16.20e-7-7.334In-Between0.395AmbiguousLikely Benign0.153Likely Benign-1.08Neutral0.016Benign0.011Benign4.26Benign0.02Affected4.3230.17520.249902-1.319.05
c.1246C>A
L416I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 L416I missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Functional prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, and FATHMM. Those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Predictions that remain inconclusive are FoldX, Rosetta, AlphaMissense‑Default, and Foldetta. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields a benign prediction. Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, is uncertain. Overall, the preponderance of evidence points to a benign effect. This conclusion is not contradicted by any ClinVar annotation, as the variant has no existing ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.104810Structured0.336105Uncertain0.9350.2270.000-8.613Likely Pathogenic0.396AmbiguousLikely Benign0.57Ambiguous0.00.69Ambiguous0.63Ambiguous0.50Likely Benign0.127Likely Benign-1.28Neutral0.997Probably Damaging0.989Probably Damaging3.38Benign0.37Tolerated0.10730.3480220.70.00
c.3496G>T
A1166S
2D
AIThe SynGAP1 missense variant A1166S is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy methods that are available—AlphaMissense‑Optimized and the SGM‑Consensus—both support a benign classification. Consequently, the variant is most likely benign according to the majority of predictive evidence, and this assessment does not contradict any ClinVar annotation because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.575842Disordered0.811691Binding0.3810.8030.375-2.587Likely Benign0.396AmbiguousLikely Benign0.308Likely Benign-0.59Neutral0.995Probably Damaging0.949Probably Damaging5.41Benign0.35Tolerated0.25680.523911-2.616.00
c.1190G>A
C397Y
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant C397Y is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are FoldX, Rosetta, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and the combined Foldetta method. Uncertain results come from AlphaMissense‑Default and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta as pathogenic. Overall, the majority of tools and the high‑accuracy consensus lean toward a benign interpretation, and this does not contradict any ClinVar classification (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.429200Structured0.395774Uncertain0.7780.5510.250-7.213In-Between0.397AmbiguousLikely Benign2.01Destabilizing2.38.64Destabilizing5.33Destabilizing0.12Likely Benign0.455Likely Benign-1.82Neutral0.952Possibly Damaging0.497Possibly Damaging4.64Benign0.07Tolerated0.12990.50840-2-3.860.04
c.2312C>A
S771Y
2D
AIThe SynGAP1 missense variant S771Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. Two tools, ESM1b and AlphaMissense‑Default, return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive because it contains two benign and two uncertain calls, and Foldetta data are unavailable. Overall, the balance of evidence favors a benign interpretation, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.436924Structured0.922503Binding0.3060.8830.250-7.041In-Between0.397AmbiguousLikely Benign0.176Likely Benign-2.13Neutral0.990Probably Damaging0.892Possibly Damaging4.02Benign0.05Affected0.07070.5155-3-2-0.576.10
c.2804C>T
A935V
2D
AIThe SynGAP1 missense variant A935V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also leans benign (2 benign vs. 1 pathogenic votes). Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for A935V, and this conclusion does not contradict any ClinVar annotation because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.736850Disordered0.980490Binding0.2860.8650.625-4.750Likely Benign0.397AmbiguousLikely Benign0.194Likely Benign-2.06Neutral0.999Probably Damaging0.996Probably Damaging2.30Pathogenic0.00Affected0.13400.5941002.428.05
c.2819G>A
G940D
2D
AIThe SynGAP1 missense variant G940D is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33443371‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Two tools, AlphaMissense‑Default and ESM1b, return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because it receives two benign and two uncertain votes, and Foldetta’s protein‑folding stability analysis is unavailable. Overall, the balance of evidence favors a benign classification, and this conclusion does not contradict the ClinVar status, which is currently unreported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.889439Disordered0.920635Binding0.3830.9020.6256-33443371-G-A63.72e-6-7.311In-Between0.397AmbiguousLikely Benign0.076Likely Benign-0.68Neutral0.770Possibly Damaging0.583Possibly Damaging2.72Benign0.17Tolerated3.7750.18370.2252-11-3.158.04
c.328G>T
V110F
2D
AIThe SynGAP1 missense variant V110F is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, SGM‑Consensus is Likely Benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.622677Disordered0.665934Binding0.3470.8600.750-4.872Likely Benign0.397AmbiguousLikely Benign0.042Likely Benign-1.63Neutral0.006Benign0.003Benign4.13Benign0.01Affected0.07940.4027-1-1-1.448.04
c.3406C>A
Q1136K
2D
AIThe SynGAP1 missense variant Q1136K is listed in gnomAD (ID 6‑33443958‑C‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.903857Disordered0.775584Binding0.3210.8840.8756-33443958-C-A-5.698Likely Benign0.397AmbiguousLikely Benign0.236Likely Benign-1.43Neutral0.625Possibly Damaging0.258Benign5.55Benign0.17Tolerated4.3220.18910.484111-0.40.04
c.710C>T
A237V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A237V is not reported in ClinVar and is absent from gnomAD. Standard in‑silico predictors are divided: benign calls come from premPS, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Optimized; pathogenic calls come from REVEL, PROVEAN, polyPhen‑2 HumDiv, and ESM1b. The remaining tools (FoldX, Rosetta, Foldetta, AlphaMissense‑Default) are uncertain. High‑accuracy assessments give a benign result from AlphaMissense‑Optimized, a pathogenic outcome from the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), and an uncertain result from Foldetta. Because the majority of conventional predictors and the optimized AlphaMissense model favor benign, the variant is most likely benign, and this assessment does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
PH0.200174Structured0.334699Uncertain0.7190.3520.000-8.927Likely Pathogenic0.397AmbiguousLikely Benign0.87Ambiguous0.40.97Ambiguous0.92Ambiguous0.18Likely Benign0.565Likely Pathogenic-3.26Deleterious0.900Possibly Damaging0.430Benign5.87Benign0.10Tolerated0.07710.4853002.428.05
c.1876A>G
I626V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I626V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Predictions that are uncertain or unavailable are AlphaMissense‑Default, FoldX, Rosetta, Foldetta, and premPS. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus also indicates a likely benign outcome, while Foldetta’s stability analysis is inconclusive. Based on the overall consensus of the available predictions, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.109221Structured0.040732Uncertain0.9700.2230.000-6.636Likely Benign0.398AmbiguousLikely Benign1.24Ambiguous0.01.06Ambiguous1.15Ambiguous0.80Ambiguous0.182Likely Benign-0.80Neutral0.969Probably Damaging0.960Probably Damaging3.33Benign0.13Tolerated0.10030.289143-0.3-14.03
c.2548G>A
G850R
2D
AIThe SynGAP1 missense variant G850R is listed in ClinVar with an uncertain significance (ClinVar ID 2042462.0) and is not reported in gnomAD. Prediction tools that classify the variant as benign include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only SIFT predicts a pathogenic effect, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized labeling the variant as benign and the SGM‑Consensus indicating a likely benign outcome; Foldetta, a protein‑folding stability method, did not provide a result for this substitution. Overall, the preponderance of evidence points to a benign impact, which aligns with the ClinVar designation of uncertain significance rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.648219Disordered0.540897Binding0.3120.8200.500Uncertain 1-5.082Likely Benign0.398AmbiguousLikely Benign0.194Likely Benign-0.07Neutral0.010Benign0.010Benign4.30Benign0.01Affected3.7750.10110.4476-3-2-4.199.14
c.2548G>C
G850R
2D
AIThe SynGAP1 missense variant G850R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus (SGM‑Consensus) derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN is “Likely Benign.” AlphaMissense‑Optimized also reports a benign prediction. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.648219Disordered0.540897Binding0.3120.8200.500-5.082Likely Benign0.398AmbiguousLikely Benign0.194Likely Benign-0.07Neutral0.010Benign0.010Benign4.30Benign0.01Affected3.7750.10110.4476-3-2-4.199.14
c.3649G>C
E1217Q
2D
AIThe SynGAP1 missense variant E1217Q is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicting benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of tools (five pathogenic vs. three benign) and the SGM Consensus support a pathogenic classification, which does not contradict the lack of ClinVar annotation. Thus, the variant is most likely pathogenic based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.599170Disordered0.493043Uncertain0.8770.5630.250-8.887Likely Pathogenic0.398AmbiguousLikely Benign0.219Likely Benign-2.16Neutral0.999Probably Damaging0.996Probably Damaging2.38Pathogenic0.00Affected0.09490.4745220.0-0.98
c.3935C>A
A1312D
2D
AIThe SynGAP1 missense variant A1312D is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors a benign outcome (2 benign vs. 1 pathogenic, with one uncertain). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the balance of evidence, particularly from the high‑accuracy tools, indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.767246Disordered0.971112Binding0.3920.9020.750-4.419Likely Benign0.398AmbiguousLikely Benign0.272Likely Benign-2.74Deleterious0.997Probably Damaging0.995Probably Damaging3.11Benign0.00Affected0.22890.29930-2-5.344.01
c.4024G>T
D1342Y
2D
AIThe SynGAP1 missense variant D1342Y is reported in gnomAD (6‑33451898‑G‑T) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions are made by polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion is not contradicted by any ClinVar status (none available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.921076Disordered0.981682Binding0.3160.6780.8756-33451898-G-T-4.108Likely Benign0.398AmbiguousLikely Benign0.095Likely Benign-1.34Neutral0.939Possibly Damaging0.496Possibly Damaging3.98Benign0.01Affected4.3240.08680.5377-3-42.248.09
c.2156A>T
N719I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant N719I is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Foldetta, premPS, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Two tools report uncertainty: Rosetta and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic. Overall, the majority of predictions lean toward a benign impact, with no conflict with ClinVar status. Thus, the variant is most likely benign based on the current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.384043Structured0.445381Uncertain0.9610.3860.000-10.794Likely Pathogenic0.399AmbiguousLikely Benign-0.19Likely Benign0.0-0.74Ambiguous-0.47Likely Benign0.40Likely Benign0.146Likely Benign-4.88Deleterious1.000Probably Damaging0.999Probably Damaging2.71Benign0.10Tolerated0.04080.4493-2-38.0-0.94
c.3122C>T
P1041L
2D
AIThe SynGAP1 missense variant P1041L is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and polyPhen‑2 HumDiv. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also resolves to benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact. This conclusion does not contradict ClinVar, which has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.962114Disordered0.967463Binding0.3450.8330.625-4.901Likely Benign0.399AmbiguousLikely Benign0.403Likely Benign-3.14Deleterious0.905Possibly Damaging0.375Benign5.46Benign1.00Tolerated0.23570.6664-3-35.416.04
c.3770C>A
S1257Y
2D
AIThe SynGAP1 missense variant S1257Y is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FATHMM, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect include PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) leans pathogenic (2 pathogenic vs 1 benign). Foldetta results are unavailable. Overall, the majority of evaluated predictors (five pathogenic vs. three benign) indicate a pathogenic impact. This conclusion does not contradict ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.541878Disordered0.482380Uncertain0.8890.5720.375-8.632Likely Pathogenic0.399AmbiguousLikely Benign0.120Likely Benign-2.65Deleterious0.989Probably Damaging0.883Possibly Damaging2.55Benign0.03Affected0.04800.4463-3-2-0.576.10
c.3799A>C
M1267L
2D
AIThe SynGAP1 missense variant M1267L is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic. Foldetta results are unavailable. Overall, the majority of evidence (five pathogenic‑predicting tools versus three benign) indicates that the variant is most likely pathogenic, and this conclusion does not contradict any ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.429200Structured0.812047Binding0.8470.6140.000-1.766Likely Benign0.399AmbiguousLikely Benign0.293Likely Benign-2.52Deleterious0.813Possibly Damaging0.456Possibly Damaging2.36Pathogenic0.00Affected0.13920.3626421.9-18.03
c.3799A>T
M1267L
2D
AIThe SynGAP1 missense variant M1267L is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence (five pathogenic‑predicting tools versus three benign‑predicting tools) indicates that M1267L is most likely pathogenic, and this conclusion does not contradict any ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.429200Structured0.812047Binding0.8470.6140.000-1.766Likely Benign0.399AmbiguousLikely Benign0.293Likely Benign-2.52Deleterious0.813Possibly Damaging0.456Possibly Damaging2.36Pathogenic0.00Affected0.13920.3626421.9-18.03
c.1981C>A
Q661K
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q661K is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. Only ESM1b predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign; the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign majority (2 benign vs. 1 pathogenic, with one uncertain), and Foldetta also predicts benign stability. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.048328Structured0.117089Uncertain0.9240.3090.000-10.581Likely Pathogenic0.400AmbiguousLikely Benign-0.01Likely Benign0.0-0.18Likely Benign-0.10Likely Benign0.04Likely Benign0.108Likely Benign-1.89Neutral0.098Benign0.030Benign3.59Benign0.42Tolerated0.17560.359211-0.40.04
c.2399G>A
G800D
2D
AIThe SynGAP1 missense variant G800D is catalogued in gnomAD (6-33442951‑G‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all classify the change as benign or likely benign. No tool predicts pathogenicity. High‑accuracy assessments reinforce this: AlphaMissense‑Optimized reports a benign outcome, and the SGM‑Consensus (derived from the majority of the four high‑accuracy predictors) also yields a benign verdict. Foldetta results are unavailable, so they do not influence the assessment. Overall, the evidence strongly supports a benign classification, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.852992Disordered0.588350Binding0.3030.8840.6256-33442951-G-A-5.929Likely Benign0.400AmbiguousLikely Benign0.088Likely Benign-0.84Neutral0.451Benign0.265Benign2.76Benign0.34Tolerated4.3220.16640.1877-11-3.158.04
c.277C>G
R93G
2D
AIThe SynGAP1 missense variant R93G is listed in ClinVar (ID 2504251.0) with an “Uncertain” clinical significance and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus (derived from the same set of predictors) labels it “Likely Benign”; Foldetta results are unavailable. Overall, the preponderance of evidence indicates that R93G is most likely benign, which does not contradict the current ClinVar status of uncertainty.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.549151Binding0.2900.8740.625Uncertain 1-2.674Likely Benign0.400AmbiguousLikely Benign0.093Likely Benign-1.69Neutral0.103Benign0.019Benign3.99Benign0.00Affected4.3210.38090.3814-2-34.1-99.14
c.3319C>A
Q1107K
2D
AIThe SynGAP1 missense variant Q1107K is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools largely support a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates a likely benign outcome. Only polyPhen‑2 HumDiv predicts a pathogenic effect, and AlphaMissense‑Default remains uncertain. High‑accuracy assessments further reinforce the benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the majority of evidence points to a benign impact, and this conclusion is not in conflict with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.951017Binding0.3930.8800.875-4.066Likely Benign0.400AmbiguousLikely Benign0.095Likely Benign-1.99Neutral0.920Possibly Damaging0.425Benign2.60Benign0.30Tolerated0.18050.527611-0.40.04
c.3223C>G
Q1075E
2D
AIThe SynGAP1 missense variant Q1075E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default remains uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. High‑accuracy assessments therefore indicate a benign outcome: AlphaMissense‑Optimized predicts benign, SGM‑Consensus is Likely Benign, and Foldetta data is missing. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.988305Binding0.3540.8940.750-2.275Likely Benign0.401AmbiguousLikely Benign0.065Likely Benign-0.70Neutral0.963Probably Damaging0.959Probably Damaging2.75Benign0.25Tolerated0.14590.2463220.00.98
c.3891G>C
R1297S
2D
AIThe SynGAP1 missense variant R1297S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the consensus of available predictions indicates that R1297S is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.859585Disordered0.895222Binding0.5110.8170.625-3.468Likely Benign0.401AmbiguousLikely Benign0.139Likely Benign-2.39Neutral0.224Benign0.096Benign2.50Benign0.07Tolerated0.28630.23470-13.7-69.11
c.3891G>T
R1297S
2D
AIThe SynGAP1 missense variant R1297S is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign classification. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions strongly suggests that R1297S is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.859585Disordered0.895222Binding0.5110.8170.625-3.468Likely Benign0.401AmbiguousLikely Benign0.139Likely Benign-2.39Neutral0.224Benign0.096Benign2.50Benign0.07Tolerated0.28630.23470-13.7-69.11
c.1076C>G
T359R
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant T359R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on benign effects include REVEL, Rosetta, Foldetta, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Optimized. Those that predict pathogenicity are SGM‑Consensus, PROVEAN, polyPhen‑2 HumDiv, ESM1b, and FATHMM. Uncertain results come from FoldX, premPS, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as benign. Overall, more tools favor a benign outcome, but a significant minority predict pathogenicity, leaving the variant’s clinical significance unresolved. The variant is most likely benign based on the prevailing predictions, and this does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicC20.281712Structured0.414952Uncertain0.9390.4800.250-8.675Likely Pathogenic0.402AmbiguousLikely Benign-0.74Ambiguous0.1-0.20Likely Benign-0.47Likely Benign0.54Ambiguous0.157Likely Benign-2.86Deleterious0.627Possibly Damaging0.091Benign1.75Pathogenic0.23Tolerated0.13230.3748-1-1-3.855.08
c.2609T>C
L870P
2D
AIThe SynGAP1 missense variant L870P is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.483068Structured0.688079Binding0.2740.8500.125-4.462Likely Benign0.402AmbiguousLikely Benign0.194Likely Benign-1.92Neutral0.999Probably Damaging0.999Probably Damaging2.59Benign0.13Tolerated0.37950.1864-3-3-5.4-16.04
c.2668C>T
R890C
2D
AIThe SynGAP1 missense variant R890C is listed in ClinVar as benign and is present in gnomAD (6-33443220-C‑T). Functional prediction tools show mixed results: benign predictions come from REVEL, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions are reported by PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM Consensus also indicates benign; Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the balance of evidence leans toward a benign effect, which is consistent with the ClinVar classification and does not contradict the reported status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.720929Disordered0.531156Binding0.2840.9280.625Benign 16-33443220-C-T95.58e-6-5.786Likely Benign0.402AmbiguousLikely Benign0.200Likely Benign-3.38Deleterious1.000Probably Damaging0.971Probably Damaging3.94Benign0.04Affected4.3240.36260.2206-4-37.0-53.05
c.3382G>T
G1128W
2D
AIThe SynGAP1 missense variant G1128W is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while ESM1b and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields an inconclusive result (two benign, two uncertain), and Foldetta data are unavailable. Overall, the balance of evidence favors a benign classification. This conclusion does not contradict ClinVar status, as the variant has no existing ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.896620Disordered0.865136Binding0.3090.9110.875-7.341In-Between0.402AmbiguousLikely Benign0.464Likely Benign-1.36Neutral0.011Benign0.008Benign4.36Benign0.02Affected0.07960.4540-7-2-0.5129.16
c.3700C>G
L1234V
2D
AIThe SynGAP1 missense variant L1234V is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. Two tools, AlphaMissense‑Default and ESM1b, return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive, and Foldetta (combining FoldX‑MD and Rosetta outputs) has no available result. Overall, the balance of evidence leans toward a benign classification, and this assessment does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.599170Disordered0.575096Binding0.8440.5270.125-7.863In-Between0.402AmbiguousLikely Benign0.090Likely Benign-1.80Neutral0.898Possibly Damaging0.602Possibly Damaging1.54Pathogenic0.50Tolerated0.13140.2918210.4-14.03
c.4019C>T
T1340I
2D
AIThe SynGAP1 missense variant T1340I is not reported in ClinVar (ClinVar status: “None”) but is present in gnomAD (ID 6‑33451893‑C‑T). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. Tools that predict a pathogenic effect are PROVEAN and SIFT. AlphaMissense‑Default is uncertain, while AlphaMissense‑Optimized predicts benign. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, resolves to benign (two benign versus one pathogenic, with the uncertain result treated as unavailable). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the high‑accuracy predictions (AlphaMissense‑Optimized, SGM Consensus) both indicate a benign impact, and no evidence contradicts this assessment with the ClinVar status. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.852992Disordered0.977899Binding0.4440.6970.7506-33451893-C-T-3.476Likely Benign0.402AmbiguousLikely Benign0.089Likely Benign-2.57Deleterious0.334Benign0.099Benign4.08Benign0.01Affected3.7750.11630.5848-105.212.05
c.802A>C
I268L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I268L is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. Two tools give uncertain results: premPS and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction, and Foldetta indicates a benign folding‑stability outcome. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.216401Structured0.314336Uncertain0.9510.2640.000-6.544Likely Benign0.402AmbiguousLikely Benign0.37Likely Benign0.1-0.07Likely Benign0.15Likely Benign0.96Ambiguous0.390Likely Benign-1.84Neutral0.981Probably Damaging0.970Probably Damaging1.65Pathogenic0.03Affected0.06350.303722-0.70.00
c.31G>T
G11W
2D
AIThe SynGAP1 missense variant G11W is catalogued in gnomAD (ID 6‑33420295‑G‑T) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions come from polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.444081Structured0.501027Binding0.3480.9150.3756-33420295-G-T-5.819Likely Benign0.403AmbiguousLikely Benign0.096Likely Benign-0.67Neutral0.959Probably Damaging0.318Benign3.87Benign0.00Affected4.3210.07470.4731-2-7-0.5129.16
c.3634T>G
S1212A
2D
AIThe SynGAP1 missense variant S1212A is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized, whereas polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM all predict a pathogenic outcome; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields benign, and Foldetta results are unavailable. Consequently, the collective evidence points to a benign classification for S1212A, and this conclusion does not conflict with the absence of a ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.566480Disordered0.548409Binding0.8520.5650.500-4.705Likely Benign0.403AmbiguousLikely Benign0.109Likely Benign-1.66Neutral0.992Probably Damaging0.987Probably Damaging2.27Pathogenic0.00Affected0.39010.3823112.6-16.00
c.949C>G
L317V
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant L317V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely disagree: benign calls come from REVEL and AlphaMissense‑Optimized, while pathogenic calls are made by FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as Likely Pathogenic. High‑accuracy assessments show AlphaMissense‑Optimized predicting Benign, SGM‑Consensus predicting Likely Pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) yielding an Uncertain result. Overall, the majority of evidence points toward pathogenicity, with only two tools indicating benign. Because ClinVar contains no entry, there is no conflict with existing clinical interpretation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicC20.106997Structured0.394031Uncertain0.8740.2400.125-8.406Likely Pathogenic0.403AmbiguousLikely Benign2.51Destabilizing0.10.97Ambiguous1.74Ambiguous1.12Destabilizing0.298Likely Benign-2.76Deleterious0.999Probably Damaging0.994Probably Damaging1.74Pathogenic0.03Affected0.15180.2950210.4-14.03
c.2189T>C
I730T
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant I730T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Predictions that are inconclusive are premPS and AlphaMissense‑Default. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized scores the variant as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign classification, and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also predicts a benign effect. Overall, the consensus of both general and high‑accuracy predictors points to a benign impact, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.420109Uncertain0.5910.6190.750-5.641Likely Benign0.404AmbiguousLikely Benign0.18Likely Benign0.20.12Likely Benign0.15Likely Benign0.54Ambiguous0.103Likely Benign-0.83Neutral0.995Probably Damaging0.934Probably Damaging3.49Benign0.08Tolerated0.10740.08850-1-5.2-12.05
c.2417T>A
F806Y
2D
AIThe SynGAP1 missense variant F806Y is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized, whereas polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM all predict a pathogenic outcome; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, the SGM Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also classifies it as benign, and Foldetta results are unavailable. Taken together, the majority of evidence points to a benign effect, and this conclusion does not contradict the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.736850Disordered0.847454Binding0.2760.9040.500-5.229Likely Benign0.404AmbiguousLikely Benign0.162Likely Benign-1.51Neutral0.997Probably Damaging0.987Probably Damaging2.32Pathogenic0.03Affected0.17460.143773-4.116.00
c.2398G>C
G800R
2D
AIThe SynGAP1 missense variant G800R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.852992Disordered0.588350Binding0.3030.8840.625-3.613Likely Benign0.405AmbiguousLikely Benign0.147Likely Benign-0.27Neutral0.003Benign0.004Benign2.84Benign0.17Tolerated0.08680.3835-3-2-4.199.14
c.3075G>C
Q1025H
2D
AIThe SynGAP1 missense variant Q1025H is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Prediction tools largely agree on a benign effect: SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the variant as benign. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence supports a benign impact, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.993410Binding0.3630.7460.500-4.976Likely Benign0.405AmbiguousLikely Benign0.051Likely Benign-1.43Neutral0.014Benign0.012Benign2.68Benign0.05Affected0.13320.3852300.39.01
c.3075G>T
Q1025H
2D
AIThe SynGAP1 missense variant Q1025H is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Prediction tools largely agree on a benign effect: SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the variant as benign. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence supports a benign impact, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.993410Binding0.3630.7460.500-4.976Likely Benign0.405AmbiguousLikely Benign0.051Likely Benign-1.43Neutral0.014Benign0.012Benign2.68Benign0.05Affected0.13320.3852300.39.01
c.3368G>A
G1123D
2D
AISynGAP1 missense variant G1123D is listed in ClinVar with an uncertain significance and is present in gnomAD (ID 6‑33443920‑G‑A). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, AlphaMissense‑Optimized, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv and ESM1b. AlphaMissense‑Default remains uncertain, and Foldetta stability analysis is unavailable. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM Consensus also benign, while Foldetta provides no result. Overall, the preponderance of evidence points to a benign effect, which does not conflict with the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.837511Disordered0.827246Binding0.3460.9340.875Uncertain 26-33443920-G-A21.33e-6-10.321Likely Pathogenic0.405AmbiguousLikely Benign0.360Likely Benign-0.78Neutral0.500Possibly Damaging0.157Benign4.34Benign0.19Tolerated3.7750.17920.20351-1-3.158.04
c.3731G>C
S1244T
2D
AISynGAP1 missense variant S1244T is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on benign effect include REVEL, PROVEAN, SIFT, and AlphaMissense‑Optimized. Tools that agree on pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments give AlphaMissense‑Optimized a benign score, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—predicts pathogenicity. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the balance of evidence leans toward pathogenicity, with four high‑confidence pathogenic predictions versus four benign predictions, and the SGM Consensus tipping the scale. This conclusion does not contradict ClinVar status, as the variant has not yet been classified in that database.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.648219Disordered0.411055Uncertain0.8330.5490.500-9.020Likely Pathogenic0.405AmbiguousLikely Benign0.149Likely Benign-1.82Neutral0.992Probably Damaging0.987Probably Damaging2.24Pathogenic0.11Tolerated0.11290.4603110.114.03
c.1408A>C
M470L
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant M470L is listed in ClinVar as benign (ClinVar ID 536996.0) and is present in gnomAD (variant ID 6‑33438440‑A‑C). Functional prediction tools cluster into two groups: benign predictions come from SIFT and AlphaMissense‑Optimized, while pathogenic predictions are made by REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. The SGM Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as likely pathogenic. High‑accuracy assessments further show AlphaMissense‑Optimized as benign, SGM Consensus as likely pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) as uncertain. No definitive folding‑stability change is reported by FoldX or Rosetta individually. Overall, the majority of predictive algorithms favor a pathogenic effect, directly contradicting the benign classification in ClinVar.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.298791Structured0.351497Uncertain0.9080.2720.000Likely Benign 16-33438440-A-C16.20e-7-8.993Likely Pathogenic0.406AmbiguousLikely Benign0.73Ambiguous0.10.84Ambiguous0.79Ambiguous1.04Destabilizing0.678Likely Pathogenic-2.72Deleterious0.484Possibly Damaging0.654Possibly Damaging-1.22Pathogenic0.16Tolerated3.37340.11920.4071421.9-18.03225.317.90.00.0-0.80.5XPotentially BenignThe thioether group of Met470, located in the middle of an α helix (res. Ala461–Phe476), interacts with hydrophobic residues in the inter-helix space (e.g., Val473, Leu558) formed by two other α helices (res. Ser604–Arg581, res. Pro562–Arg579). In the WT simulations, Met470 also packs against the positively charged guanidinium groups of Arg575, Arg429, and Arg579, which form salt bridges with the negatively charged carboxylate groups of the Asp474 and Asp467 side chains at the protein surface. In the variant simulations, the iso-butyl side chain of Leu470 packs similarly with the hydrophobic residues as methionine, resulting in no negative effects on the protein structure during the simulation.
c.1408A>T
M470L
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant M470L is not reported in ClinVar and has no gnomAD entry. Prediction tools that agree on benign effect include SIFT and AlphaMissense‑Optimized. Tools that agree on pathogenic effect include SGM Consensus, REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. AlphaMissense‑Default, FoldX, Rosetta, and Foldetta are inconclusive and are treated as unavailable. High‑accuracy assessments show AlphaMissense‑Optimized predicts a benign outcome, whereas the SGM Consensus (a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) predicts likely pathogenic. Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, is uncertain. Overall, the majority of evidence points to a pathogenic effect, and this conclusion does not contradict the ClinVar status, which currently has no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.298791Structured0.351497Uncertain0.9080.2720.000-8.993Likely Pathogenic0.406AmbiguousLikely Benign0.73Ambiguous0.10.84Ambiguous0.79Ambiguous1.04Destabilizing0.678Likely Pathogenic-2.72Deleterious0.484Possibly Damaging0.654Possibly Damaging-1.22Pathogenic0.16Tolerated3.37340.11920.4071421.9-18.03225.317.90.00.0-0.80.5XPotentially BenignThe thioether group of Met470, located in the middle of an α helix (res. Ala461–Phe476), interacts with hydrophobic residues in the inter-helix space (e.g., Val473, Leu558) formed by two other α helices (res. Ser604–Arg581, res. Pro562–Arg579). In the WT simulations, Met470 also packs against the positively charged guanidinium groups of Arg575, Arg429, and Arg579, which form salt bridges with the negatively charged carboxylate groups of the Asp474 and Asp467 side chains at the protein surface. In the variant simulations, the iso-butyl side chain of Leu470 packs similarly with the hydrophobic residues as methionine, resulting in no negative effects on the protein structure during the simulation.
c.1999A>G
I667V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 I667V missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. Only ESM1b predicts a pathogenic outcome; all other tools (FoldX, Rosetta, premPS, AlphaMissense‑Default, Foldetta) are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, while the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign majority vote. Foldetta’s stability prediction is uncertain. Overall, the preponderance of evidence points to a benign effect. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.142424Structured0.083597Uncertain0.9270.3790.000-8.482Likely Pathogenic0.406AmbiguousLikely Benign1.32Ambiguous0.01.06Ambiguous1.19Ambiguous0.85Ambiguous0.234Likely Benign-0.86Neutral0.341Benign0.052Benign3.35Benign0.15Tolerated0.11780.305943-0.3-14.03
c.3432G>C
L1144F
2D
AIThe SynGAP1 missense variant L1144F is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for the variant, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.726803Binding0.2770.8401.000-4.375Likely Benign0.406AmbiguousLikely Benign0.415Likely Benign-1.71Neutral0.999Probably Damaging0.969Probably Damaging5.69Benign0.04Affected0.06850.328320-1.034.02
c.3432G>T
L1144F
2D
AIThe SynGAP1 missense variant L1144F is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions come from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the aggregate evidence, the variant is most likely benign. This assessment does not contradict ClinVar status, as no ClinVar claim exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.950334Disordered0.726803Binding0.2770.8401.000-4.375Likely Benign0.406AmbiguousLikely Benign0.415Likely Benign-1.71Neutral0.999Probably Damaging0.969Probably Damaging5.69Benign0.04Affected0.06850.328320-1.034.02
c.413A>G
K138R
2D
AIThe SynGAP1 missense variant K138R is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support this view: AlphaMissense‑Optimized reports a benign effect, and the SGM‑Consensus likewise indicates Likely Benign; Foldetta results are unavailable. Taken together, the preponderance of evidence points to a benign impact for K138R, and this conclusion does not conflict with the absence of a ClinVar assertion. The variant is most likely benign, and this assessment does not contradict the ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.590140Disordered0.619482Binding0.3490.9010.375-5.135Likely Benign0.406AmbiguousLikely Benign0.115Likely Benign-1.58Neutral0.247Benign0.163Benign3.66Benign0.02Affected0.45550.103632-0.628.01
c.446A>G
K149R
2D
AIThe SynGAP1 missense variant K149R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields a benign classification. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that K149R is most likely benign, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.562014Disordered0.501681Binding0.3020.8390.625-8.237Likely Pathogenic0.406AmbiguousLikely Benign0.143Likely Benign-1.70Neutral0.247Benign0.125Benign3.70Benign0.00Affected0.56390.1169Weaken32-0.628.01
c.603T>A
D201E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 D201E missense variant (ClinVar ID 3004688.0) is classified as **Benign** in ClinVar and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while Rosetta, Foldetta, and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as **Benign**, the SGM‑Consensus as **Likely Benign**, and Foldetta as **Uncertain**. Taken together, the overwhelming majority of evidence points to a benign impact, and this conclusion aligns with the ClinVar designation. Thus, the variant is most likely benign, with no contradiction to its ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.366687Structured0.428570Uncertain0.6980.4470.125Benign 1-2.640Likely Benign0.406AmbiguousLikely Benign0.42Likely Benign0.21.99Ambiguous1.21Ambiguous0.23Likely Benign0.165Likely Benign-0.69Neutral0.633Possibly Damaging0.108Benign4.30Benign1.00Tolerated3.4690.10690.5505320.014.03258.7-24.80.90.1-0.30.2XUncertainAsp201, an acidic residue located in the N-terminal loop before the first anti-parallel β sheet strand (res. Ile205-Pro208), is replaced by another acidic residue, glutamate. The carboxylate groups of both Asp201 and Glu201 side chains form hydrogen bonds with the hydroxyl group of Ser221 in the simulations. Due to its shorter side chain, Asp201 can also hydrogen bond with the backbone amide groups of neighboring loop residues Ser204 and Asp203. However, since the model ends abruptly at the N-terminus, no definite conclusions can be drawn from the simulations.
c.603T>G
D201E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 D201E missense variant (gnomAD ID 6‑33435245‑T‑G) is listed in ClinVar with an uncertain significance. Across a broad panel of in silico predictors, the majority indicate a benign effect: REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all score benign. Only polyPhen‑2 HumDiv predicts pathogenicity, while Rosetta, Foldetta, and AlphaMissense‑Default remain inconclusive. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, resolves to “likely benign.” High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and Foldetta is inconclusive. Taken together, the preponderance of evidence points to a benign impact, which does not conflict with the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.366687Structured0.428570Uncertain0.6980.4470.125Conflicting 26-33435245-T-G201.24e-5-2.640Likely Benign0.406AmbiguousLikely Benign0.42Likely Benign0.21.99Ambiguous1.21Ambiguous0.23Likely Benign0.165Likely Benign-0.69Neutral0.633Possibly Damaging0.108Benign4.30Benign1.00Tolerated3.4690.10690.5505320.014.03258.7-24.80.90.1-0.30.2XUncertainAsp201, an acidic residue located in the N-terminal loop before the first anti-parallel β sheet strand (res. Ile205-Pro208), is replaced by another acidic residue, glutamate. The carboxylate groups of both Asp201 and Glu201 side chains form hydrogen bonds with the hydroxyl group of Ser221 in the simulations. Due to its shorter side chain, Asp201 can also hydrogen bond with the backbone amide groups of neighboring loop residues Ser204 and Asp203. However, since the model ends abruptly at the N-terminus, no definite conclusions can be drawn from the simulations.
c.1318A>G
N440D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant N440D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Optimized. Only ESM1b predicts a pathogenic outcome, while FoldX, Foldetta, and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta as uncertain. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.191378Structured0.267204Uncertain0.9290.2450.000-9.335Likely Pathogenic0.407AmbiguousLikely Benign-0.62Ambiguous0.0-0.41Likely Benign-0.52Ambiguous0.47Likely Benign0.074Likely Benign-1.71Neutral0.229Benign0.045Benign3.43Benign0.43Tolerated0.15440.2025210.00.98
c.3862A>G
K1288E
2D
AISynGAP1 missense variant K1288E is listed in ClinVar with an uncertain significance and is present in gnomAD (ID 6‑33447910‑A‑G). Functional prediction tools cluster into two groups: benign predictions come from REVEL, ESM1b, and AlphaMissense‑Optimized, while pathogenic predictions are made by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, whereas the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—labels the variant pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this change. Overall, the preponderance of evidence points to a pathogenic effect, which is consistent with the ClinVar designation of uncertain significance rather than a clear benign classification. Thus, the variant is most likely pathogenic, and this does not contradict the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.827927Disordered0.814714Binding0.5380.7840.625Uncertain 16-33447910-A-G53.22e-6-2.751Likely Benign0.407AmbiguousLikely Benign0.185Likely Benign-3.27Deleterious0.979Probably Damaging0.973Probably Damaging2.13Pathogenic0.00Affected3.7750.36270.0676100.40.94
c.779T>C
V260A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 V260A missense variant is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, the SGM‑Consensus (majority vote), and Foldetta. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Two tools (premPS and AlphaMissense‑Default) give uncertain results. High‑accuracy assessments—AlphaMissense‑Optimized, the SGM‑Consensus, and Foldetta—all indicate a benign outcome. Consequently, the variant is most likely benign based on the collective predictions, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignC20.254060Structured0.382651Uncertain0.8880.2590.250-3.271Likely Benign0.407AmbiguousLikely Benign0.38Likely Benign0.00.02Likely Benign0.20Likely Benign0.81Ambiguous0.487Likely Benign-1.41Neutral0.994Probably Damaging0.970Probably Damaging5.87Benign0.33Tolerated0.26760.190300-2.4-28.05
c.990C>A
D330E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 D330E missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are Rosetta and FATHMM. The remaining tools—FoldX, AlphaMissense‑Default, and Foldetta—return uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta as uncertain. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by any ClinVar annotation, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.380708Structured0.360008Uncertain0.8050.4880.250-3.427Likely Benign0.407AmbiguousLikely Benign0.98Ambiguous0.22.31Destabilizing1.65Ambiguous0.39Likely Benign0.073Likely Benign-1.38Neutral0.122Benign0.030Benign0.97Pathogenic0.67Tolerated0.14640.4416320.014.03
c.990C>G
D330E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 D330E missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are Rosetta and FATHMM. The remaining tools—FoldX, AlphaMissense‑Default, and Foldetta—return uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta as uncertain. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by any ClinVar annotation, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.380708Structured0.360008Uncertain0.8050.4880.250-3.427Likely Benign0.407AmbiguousLikely Benign0.98Ambiguous0.22.31Destabilizing1.65Ambiguous0.39Likely Benign0.075Likely Benign-1.38Neutral0.122Benign0.030Benign0.97Pathogenic0.67Tolerated0.14640.4416320.014.03
c.1286G>T
R429L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant R429L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, the SGM‑Consensus as Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as Benign. No contradictory evidence is present from ClinVar or gnomAD. **Based on the aggregate predictions, the variant is most likely benign, and this conclusion does not contradict any ClinVar status.**

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.074921Structured0.390504Uncertain0.9590.2900.000-6.495Likely Benign0.408AmbiguousLikely Benign-0.05Likely Benign0.10.06Likely Benign0.01Likely Benign-0.12Likely Benign0.241Likely Benign-1.20Neutral1.000Probably Damaging0.998Probably Damaging3.59Benign0.37Tolerated0.15550.4025-3-28.3-43.03
c.2168C>G
T723R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T723R has no ClinVar entry and is not reported in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, Rosetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify it as benign. Two tools (polyPhen‑2 HumDiv and HumVar) predict it to be pathogenic, while FoldX, Foldetta, and AlphaMissense‑Default are uncertain. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as likely benign. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM Consensus as likely benign, and Foldetta as uncertain. Overall, the preponderance of evidence points to a benign impact for T723R, and this conclusion does not contradict any ClinVar status (none available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.476583Structured0.458243Uncertain0.9450.4470.375-3.654Likely Benign0.408AmbiguousLikely Benign-0.90Ambiguous0.1-0.13Likely Benign-0.52Ambiguous0.44Likely Benign0.146Likely Benign-1.50Neutral0.931Possibly Damaging0.458Possibly Damaging3.51Benign0.29Tolerated0.07940.2437-1-1-3.855.08
c.2258C>A
A753D
2D
AISynGAP1 missense variant A753D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Consensus from multiple in‑silico predictors indicates a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all score benign, while only polyPhen‑2 HumDiv predicts pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy tools corroborate this view: AlphaMissense‑Optimized reports a benign outcome, SGM‑Consensus likewise indicates Likely Benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta) has no available result for this variant. Overall, the computational evidence overwhelmingly supports a benign classification, and this conclusion does not contradict the ClinVar status. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.521092Disordered0.722781Binding0.3810.8730.625-5.836Likely Benign0.408AmbiguousLikely Benign0.113Likely Benign-1.66Neutral0.669Possibly Damaging0.265Benign2.60Benign0.60Tolerated0.21510.22000-2-5.344.01
c.2446T>A
S816T
2D
AIThe SynGAP1 missense variant S816T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.476583Structured0.747189Binding0.3470.8980.375-3.957Likely Benign0.408AmbiguousLikely Benign0.064Likely Benign-1.05Neutral0.990Probably Damaging0.846Possibly Damaging2.65Benign0.32Tolerated0.15730.5529110.114.03
c.3326T>G
L1109R
2D
AIThe SynGAP1 missense variant L1109R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.856457Disordered0.948334Binding0.3430.8930.875-5.440Likely Benign0.408AmbiguousLikely Benign0.139Likely Benign-0.70Neutral0.586Possibly Damaging0.225Benign2.68Benign0.34Tolerated0.13520.1919-3-2-8.343.03
c.569G>C
S190T
2D
AIThe SynGAP1 missense variant S190T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus confirms Likely Benign, and Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.422041Structured0.428613Uncertain0.3380.6150.250-6.870Likely Benign0.408AmbiguousLikely Benign0.114Likely Benign-1.31Neutral0.608Possibly Damaging0.108Benign4.08Benign0.20Tolerated0.12940.6920110.114.03
c.2365C>T
P789S
2D
AIThe SynGAP1 P789S variant has no ClinVar entry (ClinVar status: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that classify it as benign include REVEL, ESM1b, and AlphaMissense‑Optimized, whereas pathogenic predictions come from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—predicts pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the balance of evidence leans toward pathogenicity, with five tools supporting a deleterious effect versus three supporting benignity. This prediction does not contradict ClinVar status, which currently has no classification for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.963420Disordered0.541575Binding0.3980.9030.750-4.793Likely Benign0.409AmbiguousLikely Benign0.221Likely Benign-4.64Deleterious1.000Probably Damaging0.999Probably Damaging2.19Pathogenic0.00Affected0.31000.34361-10.8-10.04
c.2939A>G
H980R
2D
AIThe SynGAP1 missense variant H980R is listed in gnomAD (ID 6‑33443491‑A‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.974598Binding0.3090.8920.6256-33443491-A-G16.20e-7-2.736Likely Benign0.409AmbiguousLikely Benign0.095Likely Benign-1.44Neutral0.802Possibly Damaging0.354Benign4.17Benign0.00Affected4.3210.24390.381002-1.319.05
c.3119G>C
G1040A
2D
AIThe SynGAP1 missense variant G1040A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are REVEL and FATHMM, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote among AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign prediction (2 benign vs. 1 pathogenic). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation, as the variant is not yet classified in that database.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.964893Disordered0.973805Binding0.3320.8160.625-2.625Likely Benign0.409AmbiguousLikely Benign0.606Likely Pathogenic-1.65Neutral0.114Benign0.030Benign-0.74Pathogenic0.30Tolerated0.32460.5331102.214.03
c.3707A>T
Q1236L
2D
AIThe SynGAP1 missense variant Q1236L is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also predicts benign, while Foldetta results are unavailable. Overall, the majority of high‑confidence predictions lean toward a benign impact, and there is no conflict with ClinVar status. Thus, the variant is most likely benign based on current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.680603Disordered0.567914Binding0.8830.5370.125-6.682Likely Benign0.409AmbiguousLikely Benign0.362Likely Benign-4.51Deleterious0.994Probably Damaging0.988Probably Damaging2.66Benign0.00Affected0.05070.3805-2-27.3-14.97
c.4001A>G
N1334S
2D
AIThe SynGAP1 missense variant N1334S is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and SIFT. AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields a benign consensus (2 benign vs. 1 pathogenic, 1 uncertain). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.915074Disordered0.960403Binding0.4060.7340.875-3.989Likely Benign0.409AmbiguousLikely Benign0.107Likely Benign-2.94Deleterious0.557Possibly Damaging0.348Benign3.56Benign0.00Affected0.35420.4708112.7-27.03
c.991T>C
S331P
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S331P is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, SIFT, ESM1b, polyPhen‑2 HumVar, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are Rosetta, polyPhen‑2 HumDiv, and FATHMM. Two tools give inconclusive results: AlphaMissense‑Default and Foldetta. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors benign, while Foldetta remains uncertain. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation and gnomAD presence, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.433034Structured0.346458Uncertain0.6580.4750.250-5.104Likely Benign0.409AmbiguousLikely Benign0.33Likely Benign0.22.35Destabilizing1.34Ambiguous0.44Likely Benign0.186Likely Benign-1.81Neutral0.784Possibly Damaging0.390Benign1.83Pathogenic0.26Tolerated0.23060.40861-1-0.810.04
c.1083G>C
Q361H
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q361H is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, premPS, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. The remaining tools—FoldX, Rosetta, ESM1b, and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive, and Foldetta (combining FoldX‑MD and Rosetta outputs) is also unavailable. Overall, the majority of conventional predictors lean toward pathogenicity, while the single high‑accuracy tool suggests benign. No ClinVar annotation exists to contradict these findings. Thus, based on the collective evidence, the variant is most likely pathogenic, with no conflict with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.305330Structured0.427593Uncertain0.9450.5340.250-7.269In-Between0.410AmbiguousLikely Benign0.68Ambiguous0.10.52Ambiguous0.60Ambiguous0.32Likely Benign0.281Likely Benign-2.73Deleterious0.996Probably Damaging0.986Probably Damaging1.79Pathogenic0.04Affected0.13520.4151300.39.01
c.1083G>T
Q361H
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q361H is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, premPS, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. The remaining tools—FoldX, Rosetta, ESM1b, and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive, and Foldetta (combining FoldX‑MD and Rosetta outputs) is also unavailable. Overall, the majority of conventional predictors (five pathogenic vs. three benign) lean toward a pathogenic interpretation, while the single high‑accuracy tool suggests benign. No ClinVar entry exists, so there is no contradiction with clinical database status. Based on the collective evidence, the variant is most likely pathogenic.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.305330Structured0.427593Uncertain0.9450.5340.250-7.269In-Between0.410AmbiguousLikely Benign0.68Ambiguous0.10.52Ambiguous0.60Ambiguous0.32Likely Benign0.281Likely Benign-2.73Deleterious0.996Probably Damaging0.986Probably Damaging1.79Pathogenic0.04Affected0.13520.4151300.39.01
c.2799C>A
H933Q
2D
AIThe SynGAP1 missense variant H933Q has no ClinVar record and is not present in gnomAD. Prediction tools that agree on a benign effect include REVEL, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain. The SGM Consensus, which takes a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, resolves to benign (two benign versus one pathogenic vote). High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus as benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta) is unavailable for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.666105Disordered0.987531Binding0.3050.8620.625-3.042Likely Benign0.410AmbiguousLikely Benign0.211Likely Benign-2.98Deleterious0.999Probably Damaging0.996Probably Damaging2.54Benign0.53Tolerated0.16540.393830-0.3-9.01
c.2799C>G
H933Q
2D
AIThe SynGAP1 H933Q missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation; there is no contradiction between the predictions and ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.666105Disordered0.987531Binding0.3050.8620.625-3.042Likely Benign0.410AmbiguousLikely Benign0.210Likely Benign-2.98Deleterious0.999Probably Damaging0.996Probably Damaging2.54Benign0.53Tolerated0.16540.393830-0.3-9.01
c.667A>T
T223S
2D
3DClick to see structure in 3D Viewer
AISynGAP1 T223S is listed in ClinVar as a variant of uncertain significance and is present in the gnomAD database (ID 6‑33435518‑A‑T). Functional prediction tools that reach consensus classify the variant as benign: FoldX, Foldetta, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Optimized. Tools that predict pathogenicity include REVEL, PROVEAN, and SIFT. Predictions that are inconclusive or uncertain are Rosetta, premPS, AlphaMissense‑Default, and ESM1b. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, Foldetta is benign, while the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive due to a 1‑to‑1 split between benign and pathogenic calls. Overall, the majority of evidence points to a benign effect, which does not contradict the ClinVar designation of uncertain significance.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
PH0.070400Structured0.382605Uncertain0.8670.3160.125Conflicting 26-33435518-A-T31.86e-6-7.714In-Between0.410AmbiguousLikely Benign0.26Likely Benign0.10.50Ambiguous0.38Likely Benign0.62Ambiguous0.535Likely Pathogenic-2.86Deleterious0.421Benign0.058Benign5.80Benign0.02Affected3.41130.23880.297211-0.1-14.03200.717.3-0.20.20.00.0XUncertainThe introduced residue Ser223 is located on the outer surface of an anti-parallel β sheet strand (res. Cys219-Thr224). Its hydroxyl group forms hydrogen bonds with nearby residues Thr228 and Lys207 in the variant simulations, similar to the hydroxyl group of Thr223 in the WT simulations. These hydrogen-bonding interactions at the β sheet surface contribute to the stability of the secondary structure element and may prevent it from unfolding. However, since the model ends abruptly at the N-terminus, no definite conclusions can be drawn from the simulations.
c.1522G>A
D508N
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 D508N missense variant is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions (REVEL, FoldX, premPS, FATHMM, AlphaMissense‑Optimized) and pathogenic predictions (PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b). Three tools remain uncertain (Rosetta, Foldetta, AlphaMissense‑Default). High‑accuracy assessments further clarify the picture: AlphaMissense‑Optimized classifies the change as benign; the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—returns a pathogenic verdict; Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, yields an inconclusive result. Because the consensus of the high‑accuracy methods is split, the overall prediction is ambiguous, but the balance of evidence leans toward pathogenicity. This assessment does not contradict ClinVar, as the variant has no ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.019401Structured0.255890Uncertain0.8900.2280.000-9.909Likely Pathogenic0.411AmbiguousLikely Benign0.11Likely Benign0.11.24Ambiguous0.68Ambiguous-0.12Likely Benign0.265Likely Benign-4.62Deleterious0.870Possibly Damaging0.615Possibly Damaging3.32Benign0.04Affected0.15770.4599210.0-0.98
c.2374G>C
E792Q
2D
AIThe SynGAP1 missense variant E792Q is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts it to be pathogenic, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” verdict, reflecting the majority of benign calls. High‑accuracy assessments further support this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority vote) is benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates that E792Q is most likely benign, and this conclusion does not contradict the absence of a ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.974374Disordered0.452261Uncertain0.3520.8960.875-3.782Likely Benign0.411AmbiguousLikely Benign0.052Likely Benign-1.60Neutral0.077Benign0.049Benign3.89Benign0.02Affected0.14690.7401220.0-0.98
c.2971G>A
G991R
2D
AIThe SynGAP1 missense variant G991R is listed in ClinVar (ID 1029090.0) with an “Uncertain” status and is present in gnomAD (variant ID 6‑33443523‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.911393Binding0.2860.9200.750Conflicting 36-33443523-G-A84.96e-6-3.934Likely Benign0.411AmbiguousLikely Benign0.102Likely Benign-1.20Neutral0.984Probably Damaging0.772Possibly Damaging4.11Benign0.01Affected4.3220.09560.4181-3-2-4.199.14
c.2971G>C
G991R
2D
AIThe SynGAP1 missense variant G991R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the majority of evidence points to a benign effect for G991R, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.745909Disordered0.911393Binding0.2860.9200.750-3.934Likely Benign0.411AmbiguousLikely Benign0.106Likely Benign-1.20Neutral0.984Probably Damaging0.772Possibly Damaging4.11Benign0.01Affected4.3220.09560.4181-3-2-4.199.14
c.965C>A
A322D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 A322D missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome. The remaining tools—FoldX, Rosetta, ESM1b, and AlphaMissense‑Default—return uncertain results and are treated as unavailable. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive, and Foldetta indicates no significant stability change (uncertain). Overall, the preponderance of evidence (seven benign predictions versus one pathogenic) suggests the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.175930Structured0.425745Uncertain0.9380.3340.000-7.184In-Between0.411AmbiguousLikely Benign0.65Ambiguous0.11.35Ambiguous1.00Ambiguous0.34Likely Benign0.246Likely Benign-0.95Neutral0.270Benign0.136Benign1.96Pathogenic0.32Tolerated0.16460.16600-2-5.344.01
c.110C>T
S37F
2D
AIThe SynGAP1 missense variant S37F is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster into two groups: benign (REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized) and pathogenic (polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT). AlphaMissense‑Default is uncertain, while the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, indicates a likely benign effect. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, SGM‑Consensus is likely benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Taken together, the preponderance of evidence from both general and high‑accuracy predictors points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing clinical classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.642678Disordered0.433492Uncertain0.3170.8060.500-4.258Likely Benign0.412AmbiguousLikely Benign0.131Likely Benign-1.77Neutral0.676Possibly Damaging0.828Possibly Damaging3.90Benign0.00Affected0.10600.5552-3-23.660.10
c.3752A>T
Q1251L
2D
AIThe SynGAP1 missense variant Q1251L is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FATHMM, and AlphaMissense‑Optimized, whereas a majority of tools (PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b) predict a pathogenic impact; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further clarify the picture: AlphaMissense‑Optimized remains benign, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—favors pathogenicity. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the balance of evidence points to a pathogenic effect, and this conclusion does not contradict the ClinVar status, which currently contains no classification for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.771762Disordered0.363872Uncertain0.8690.5510.875-10.298Likely Pathogenic0.412AmbiguousLikely Benign0.279Likely Benign-4.71Deleterious0.994Probably Damaging0.988Probably Damaging2.58Benign0.00Affected0.06260.4605-2-27.3-14.97
c.1103C>A
P368Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 P368Q missense variant has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. Remaining tools (AlphaMissense‑Default, FoldX, Rosetta, Foldetta, premPS) give uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the majority of definitive predictions (five pathogenic vs. three benign) indicate that the variant is most likely pathogenic, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.363090Structured0.439989Uncertain0.5800.6770.250-6.019Likely Benign0.413AmbiguousLikely Benign1.56Ambiguous0.81.71Ambiguous1.64Ambiguous0.71Ambiguous0.205Likely Benign-5.10Deleterious0.991Probably Damaging0.881Possibly Damaging1.71Pathogenic0.04Affected0.16940.52830-1-1.931.01
c.118G>C
D40H
2D
AIThe SynGAP1 missense variant D40H is reported in ClinVar as “Not submitted” and is not present in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic call comes from SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, SGM‑Consensus indicates likely benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Overall, the consensus of available predictions points to a benign impact, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.384043Structured0.432002Uncertain0.3190.7690.375-4.108Likely Benign0.413AmbiguousLikely Benign0.147Likely Benign-1.28Neutral0.172Benign0.248Benign3.99Benign0.00Affected0.31230.90071-10.322.05
c.2246G>T
R749L
2D
AIThe SynGAP1 missense variant R749L is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster around a benign effect: REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy predictors that are available—AlphaMissense‑Optimized and the SGM‑Consensus—both support a benign classification. Consequently, the overall evidence points to the variant being most likely benign, and this assessment does not conflict with the absence of a ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.626050Binding0.3370.8600.625-3.926Likely Benign0.413AmbiguousLikely Benign0.168Likely Benign-2.15Neutral0.999Probably Damaging0.997Probably Damaging2.65Benign0.01Affected0.21060.5154-3-28.3-43.03
c.2249G>A
G750E
2D
AISynGAP1 missense variant G750E is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, which does not contradict the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.618285Disordered0.646832Binding0.3480.8660.625Uncertain 1-2.618Likely Benign0.413AmbiguousLikely Benign0.146Likely Benign-2.27Neutral1.000Probably Damaging0.982Probably Damaging2.49Pathogenic0.01Affected3.9950.13260.37680-2-3.172.06
c.2419T>C
Y807H
2D
AIThe SynGAP1 missense variant Y807H is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that indicate a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. AlphaMissense‑Default is uncertain. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as pathogenic. AlphaMissense‑Optimized remains benign, while Foldetta results are unavailable. Overall, the majority of high‑accuracy and consensus predictors (five out of six) suggest a pathogenic impact, whereas only three predict benign. Consequently, the variant is most likely pathogenic based on current computational evidence, and this assessment does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.699094Disordered0.853760Binding0.3360.9010.500-5.879Likely Benign0.413AmbiguousLikely Benign0.152Likely Benign-2.74Deleterious0.989Probably Damaging0.913Probably Damaging2.44Pathogenic0.00Affected0.25300.070402-1.9-26.03
c.3125A>G
Q1042R
2D
AIThe SynGAP1 missense variant Q1042R is listed in ClinVar (ID 2662705.0) with an “Uncertain” clinical significance and is present in gnomAD (variant ID 6‑33443677‑A‑G). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized reports benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign.” Foldetta results are unavailable. Overall, the majority of evidence supports a benign impact for Q1042R, and this conclusion does not contradict the ClinVar status, which remains uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.959333Binding0.3100.8460.625Uncertain 26-33443677-A-G21.24e-6-2.928Likely Benign0.413AmbiguousLikely Benign0.300Likely Benign-1.39Neutral0.586Possibly Damaging0.120Benign5.48Benign0.12Tolerated3.7750.19290.388711-1.028.06
c.3509G>A
S1170N
2D
AIThe SynGAP1 missense variant S1170N is reported in gnomAD (6‑33444544‑G‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. AlphaMissense‑Default is uncertain, and no Foldetta stability assessment is available. High‑accuracy predictions from AlphaMissense‑Optimized and the SGM‑Consensus both indicate a benign outcome, while the absence of a Foldetta result leaves that aspect unresolved. Overall, the majority of evidence points to a benign effect for S1170N, and this conclusion is not contradicted by any ClinVar classification (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.622677Disordered0.719138Binding0.4170.7670.5006-33444544-G-A16.20e-7-3.705Likely Benign0.413AmbiguousLikely Benign0.342Likely Benign-0.18Neutral0.992Probably Damaging0.925Probably Damaging5.39Benign0.86Tolerated4.3240.11320.423811-2.727.03
c.1508A>C
Q503P
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q503P is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include only AlphaMissense‑Optimized. Those that predict a pathogenic effect comprise SGM‑Consensus, REVEL, Rosetta, Foldetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM; the remaining tools (FoldX, premPS, AlphaMissense‑Default) are inconclusive. High‑accuracy methods give a consistent pathogenic signal: AlphaMissense‑Optimized predicts benign, but the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) and Foldetta both predict pathogenic. Because the majority of evidence points to a deleterious effect, the variant is most likely pathogenic, and this assessment does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.040537Structured0.322935Uncertain0.8480.1680.000-10.915Likely Pathogenic0.414AmbiguousLikely Benign1.06Ambiguous0.75.94Destabilizing3.50Destabilizing0.75Ambiguous0.860Likely Pathogenic-5.20Deleterious0.999Probably Damaging0.991Probably Damaging-1.53Pathogenic0.03Affected0.20760.36100-11.9-31.01
c.2195G>T
R732M
2D
AIThe SynGAP1 missense variant R732M is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and ESM1b. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors a benign outcome. Foldetta results are unavailable. Overall, the balance of evidence (5 benign vs 3 pathogenic predictions) indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.846163Disordered0.412403Uncertain0.4270.6730.750-9.956Likely Pathogenic0.414AmbiguousLikely Benign0.098Likely Benign-1.42Neutral0.840Possibly Damaging0.357Benign2.55Benign0.01Affected0.14320.29800-16.4-24.99
c.2402G>A
G801D
2D
AIThe SynGAP1 missense variant G801D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the single pathogenic call comes from polyPhen‑2 HumDiv. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates likely benign. Foldetta results are not available, so they do not influence the assessment. Overall, the majority of evidence points to a benign effect, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.874069Disordered0.636323Binding0.3200.8920.625-5.312Likely Benign0.414AmbiguousLikely Benign0.066Likely Benign-0.69Neutral0.611Possibly Damaging0.346Benign2.84Benign0.25Tolerated0.16310.18351-1-3.158.04
c.3516C>A
H1172Q
2D
AIThe SynGAP1 missense variant H1172Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus confirms Likely Benign, and Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.626927Disordered0.673805Binding0.4650.7580.625-2.169Likely Benign0.414AmbiguousLikely Benign0.227Likely Benign-0.51Neutral0.451Benign0.265Benign5.47Benign0.39Tolerated0.12490.355730-0.3-9.01
c.3516C>G
H1172Q
2D
AIThe SynGAP1 missense variant H1172Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus confirms Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta) has no available result for this variant. Based on the collective predictions, H1172Q is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.626927Disordered0.673805Binding0.4650.7580.625-2.169Likely Benign0.414AmbiguousLikely Benign0.227Likely Benign-0.51Neutral0.451Benign0.265Benign5.47Benign0.39Tolerated0.12490.355730-0.3-9.01
c.839A>T
Y280F
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Y280F is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include FoldX, Rosetta, Foldetta, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. The remaining tools—premPS, ESM1b, and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as benign, while the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive and therefore unavailable. Overall, the majority of available predictions favor a pathogenic impact, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.161087Structured0.321243Uncertain0.9170.2480.125-7.844In-Between0.414AmbiguousLikely Benign0.49Likely Benign0.20.03Likely Benign0.26Likely Benign0.87Ambiguous0.544Likely Pathogenic-3.68Deleterious0.999Probably Damaging0.992Probably Damaging1.98Pathogenic0.02Affected0.22630.2398734.1-16.00
c.2372A>C
K791T
2D
AIThe SynGAP1 missense variant K791T is listed in gnomAD (ID 6‑33442924‑A‑C) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). No tool predicts pathogenicity. The high‑accuracy assessments corroborate this: AlphaMissense‑Optimized reports a benign outcome, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence overwhelmingly supports a benign classification, and this is consistent with the absence of a ClinVar pathogenic designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.966441Disordered0.478670Uncertain0.3560.8960.8756-33442924-A-C21.24e-6-1.578Likely Benign0.415AmbiguousLikely Benign0.033Likely Benign-0.92Neutral0.032Benign0.017Benign4.17Benign0.16Tolerated3.6460.27340.3340-103.2-27.07
c.2155A>G
N719D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant N719D is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that classify the variant as benign include REVEL, FoldX, premPS, SIFT, FATHMM, AlphaMissense‑Optimized, and Foldetta. Those that predict pathogenicity are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Two tools give uncertain results: Rosetta and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic. Overall, the majority of individual predictors (seven benign vs. four pathogenic) support a benign effect, and this conclusion does not contradict the lack of ClinVar annotation. Thus, based on the available predictions, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.384043Structured0.445381Uncertain0.9610.3860.000-9.016Likely Pathogenic0.416AmbiguousLikely Benign-0.03Likely Benign0.00.64Ambiguous0.31Likely Benign0.46Likely Benign0.106Likely Benign-2.56Deleterious0.999Probably Damaging0.995Probably Damaging2.75Benign0.84Tolerated0.15810.2345210.00.98
c.3401C>T
T1134I
2D
AIThe SynGAP1 missense variant T1134I is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also reports a benign prediction. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.885302Disordered0.813034Binding0.3350.8850.875-4.072Likely Benign0.416AmbiguousLikely Benign0.242Likely Benign-1.93Neutral0.453Possibly Damaging0.162Benign5.52Benign0.44Tolerated0.10710.54470-15.212.05
c.3508A>T
S1170C
2D
AIThe S1170C missense change occurs in a coiled‑coil region of SynGAP1. ClinVar has no entry for this variant, and it is not reported in gnomAD. Prediction tools that agree on a benign effect include PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized; those that predict a pathogenic effect are REVEL, polyPhen‑2 (HumDiv and HumVar), and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a “Likely Benign” status. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also as likely benign, while Foldetta results are unavailable. Overall, the balance of evidence, particularly from the high‑accuracy tools, points to a benign impact for S1170C. This conclusion is not contradicted by ClinVar, which currently contains no classification for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.622677Disordered0.719138Binding0.4170.7670.500-6.393Likely Benign0.416AmbiguousLikely Benign0.566Likely Pathogenic-2.07Neutral0.999Probably Damaging0.992Probably Damaging5.30Benign0.02Affected0.08720.58500-13.316.06
c.3828C>A
D1276E
2D
AIThe SynGAP1 missense variant D1276E is catalogued in gnomAD (ID 6‑33447876‑C‑A) but has no ClinVar submission. Functional prediction tools show a split assessment: benign calls come from REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, and AlphaMissense‑Optimized, whereas pathogenic calls arise from PROVEAN, SIFT, and FATHMM; AlphaMissense‑Default remains uncertain. A high‑accuracy consensus (SGM) that aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN yields a pathogenic verdict. AlphaMissense‑Optimized alone predicts benign, and no Foldetta stability data are available. Overall, the majority of individual predictors favor a benign effect, but the SGM consensus contradicts this by labeling the variant pathogenic. Because ClinVar contains no classification, there is no external evidence to resolve the discrepancy. Thus, based on the current computational evidence, the variant is most likely benign, though the SGM consensus suggests a possible pathogenic interpretation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.666105Disordered0.802156Binding0.6360.7050.6256-33447876-C-A-0.388Likely Benign0.416AmbiguousLikely Benign0.091Likely Benign-2.64Deleterious0.027Benign0.020Benign1.26Pathogenic0.00Affected3.7750.10270.5365230.014.03
c.3828C>G
D1276E
2D
AIThe SynGAP1 missense variant D1276E is not reported in ClinVar and is absent from gnomAD. Consensus from routine in silico predictors shows a split: benign calls from REVEL, polyPhen‑2 (HumDiv and HumVar), and ESM1b, versus pathogenic calls from PROVEAN, SIFT, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments give a benign result from AlphaMissense‑Optimized, but the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—leans pathogenic. Foldetta, a protein‑folding stability method, has no available output for this residue. Overall, the balance of evidence tilts toward a benign interpretation, and this conclusion is not in conflict with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.666105Disordered0.802156Binding0.6360.7050.625-0.388Likely Benign0.416AmbiguousLikely Benign0.092Likely Benign-2.64Deleterious0.027Benign0.020Benign1.26Pathogenic0.00Affected3.7750.10270.5365230.014.03
c.778G>C
V260L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 V260L missense change is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions come from FoldX, Rosetta, premPS, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions arise from REVEL, polyPhen‑2 (HumDiv and HumVar) and ESM1b. The high‑accuracy assessment shows AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors benign, and Foldetta predicts a benign effect on protein stability. No prediction is missing or inconclusive. Overall, the evidence points to a benign effect for V260L, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.254060Structured0.382651Uncertain0.8880.2590.250-8.785Likely Pathogenic0.416AmbiguousLikely Benign-0.26Likely Benign0.10.15Likely Benign-0.06Likely Benign0.25Likely Benign0.532Likely Pathogenic-1.84Neutral0.994Probably Damaging0.970Probably Damaging5.90Benign0.11Tolerated0.07300.436021-0.414.03
c.778G>T
V260L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 V260L missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are REVEL, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) also predicts benign stability. No prediction or folding result is missing or inconclusive. Overall, the variant is most likely benign based on the aggregate predictions, and this assessment does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.254060Structured0.382651Uncertain0.8880.2590.250-8.785Likely Pathogenic0.416AmbiguousLikely Benign-0.26Likely Benign0.10.15Likely Benign-0.06Likely Benign0.25Likely Benign0.532Likely Pathogenic-1.84Neutral0.994Probably Damaging0.970Probably Damaging5.90Benign0.11Tolerated0.07300.436021-0.414.03
c.1039A>C
T347P
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 T347P variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, Rosetta, Foldetta, PROVEAN, polyPhen‑2 HumVar, SIFT, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, ESM1b, and FATHMM. Three tools (FoldX, premPS, AlphaMissense‑Default) give uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as benign. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the lack of ClinVar annotation. Thus, the variant is most likely benign based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.268042Structured0.349915Uncertain0.9510.4340.000-9.323Likely Pathogenic0.417AmbiguousLikely Benign0.55Ambiguous0.00.28Likely Benign0.42Likely Benign0.65Ambiguous0.236Likely Benign-2.41Neutral0.627Possibly Damaging0.139Benign1.63Pathogenic0.12Tolerated0.20000.53500-1-0.9-3.99
c.2609T>A
L870Q
2D
AIThe SynGAP1 missense variant L870Q is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions come from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, indicates a likely benign effect. High‑accuracy assessments further support this view: AlphaMissense‑Optimized classifies the variant as benign, and the SGM‑Consensus itself is labeled likely benign. No output is available from the Foldetta stability analysis, so it does not influence the overall assessment. Based on the aggregate predictions, the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.483068Structured0.688079Binding0.2740.8500.125-4.029Likely Benign0.417AmbiguousLikely Benign0.185Likely Benign-1.90Neutral0.999Probably Damaging0.999Probably Damaging2.63Benign0.02Affected0.10270.1003-2-2-7.314.97
c.3989A>T
Q1330L
2D
AIThe SynGAP1 missense variant Q1330L is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and SIFT. AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction. Foldetta results are unavailable. Overall, the majority of evidence (5 benign vs 3 pathogenic) supports a benign classification. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.943310Disordered0.931969Binding0.3690.7520.875-3.780Likely Benign0.417AmbiguousLikely Benign0.110Likely Benign-2.74Deleterious0.784Possibly Damaging0.341Benign3.92Benign0.02Affected0.07410.5480-2-27.3-14.97
c.1417G>A
V473I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V473I is listed in ClinVar with an uncertain significance and is present in gnomAD (ID 6‑33438449‑G‑A). Functional prediction tools that agree on benign impact include REVEL, FoldX, premPS, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Pathogenic predictions are provided by both polyPhen‑2 HumDiv and HumVar. Predictions that are inconclusive are AlphaMissense‑Default, ESM1b, Foldetta, and Rosetta. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is unavailable due to no majority, and Foldetta is uncertain. Overall, the balance of evidence favors a benign effect for V473I, which does not contradict the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.191378Structured0.362529Uncertain0.8840.2390.000Uncertain 16-33438449-G-A16.20e-7-7.481In-Between0.418AmbiguousLikely Benign-0.12Likely Benign0.01.20Ambiguous0.54Ambiguous-0.06Likely Benign0.203Likely Benign-0.91Neutral0.929Possibly Damaging0.917Probably Damaging3.74Benign0.18Tolerated3.37340.05680.3335340.314.03
c.1433A>G
E478G
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 E478G missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and polyPhen‑2 HumDiv. Uncertain predictions come from Rosetta, ESM1b, AlphaMissense‑Default, and Foldetta. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to equal benign and pathogenic signals and two uncertain calls; Foldetta likewise yields an uncertain result. Overall, the majority of evaluated tools (seven benign vs. two pathogenic) support a benign classification. This consensus does not contradict any ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.264545Structured0.414660Uncertain0.7870.2490.000-7.897In-Between0.418AmbiguousLikely Benign0.40Likely Benign0.00.73Ambiguous0.57Ambiguous0.02Likely Benign0.306Likely Benign-4.91Deleterious0.923Possibly Damaging0.427Benign3.41Benign0.15Tolerated0.27580.55720-23.1-72.06
c.1669T>A
S557T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S557T is not reported in ClinVar (ClinVar ID None) and has no entry in gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include premPS, SIFT, and AlphaMissense‑Optimized. Those that predict a pathogenic effect comprise REVEL, FoldX, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Predictions that are uncertain (AlphaMissense‑Default and Foldetta) are treated as unavailable. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM Consensus as pathogenic, and Foldetta as uncertain. Overall, the majority of available predictions indicate a pathogenic impact. This conclusion is not contradicted by ClinVar status, which has no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.028107Structured0.010261Uncertain0.9240.2150.000-9.089Likely Pathogenic0.418AmbiguousLikely Benign2.14Destabilizing0.20.40Likely Benign1.27Ambiguous0.21Likely Benign0.744Likely Pathogenic-2.53Deleterious0.826Possibly Damaging0.872Possibly Damaging-1.64Pathogenic0.07Tolerated0.15140.6336110.114.03
c.220A>C
S74R
2D
AIThe SynGAP1 missense variant S74R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (majority of the high‑accuracy tools) also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign effect, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.505461Disordered0.450156Uncertain0.2940.8310.500-3.271Likely Benign0.418AmbiguousLikely Benign0.065Likely Benign-1.34Neutral0.361Benign0.019Benign4.08Benign0.00Affected4.3210.09430.3562-10-3.769.11
c.222C>A
S74R
2D
AIThe SynGAP1 missense variant S74R is catalogued in gnomAD (ID 6‑33425830‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all report benign or likely benign. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments confirm the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus, derived from the majority of the high‑confidence predictors, is benign. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that S74R is most likely benign, and this assessment does not contradict any ClinVar status, as none is reported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.505461Disordered0.450156Uncertain0.2940.8310.5006-33425830-C-A16.20e-7-3.271Likely Benign0.418AmbiguousLikely Benign0.070Likely Benign-1.34Neutral0.361Benign0.019Benign4.08Benign0.00Affected4.3210.09430.3562-10-3.769.11
c.222C>G
S74R
2D
AIThe SynGAP1 missense variant S74R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority of the high‑accuracy tools) is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.505461Disordered0.450156Uncertain0.2940.8310.500-3.271Likely Benign0.418AmbiguousLikely Benign0.070Likely Benign-1.34Neutral0.361Benign0.019Benign4.08Benign0.00Affected4.3210.09430.3562-10-3.769.11
c.2349G>A
M783I
2D
AIThe SynGAP1 missense variant M783I is listed in ClinVar as a benign alteration (ClinVar ID 3618151.0) and is present in the gnomAD database (gnomAD ID 6‑33442901‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). No tool in the dataset predicts a pathogenic outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates a likely benign effect. The Foldetta protein‑folding stability analysis is not available for this variant. Overall, the computational evidence strongly suggests that the variant is most likely benign, in agreement with its ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.736850Disordered0.738119Binding0.3310.8890.625Benign 16-33442901-G-A63.72e-6-3.560Likely Benign0.418AmbiguousLikely Benign0.042Likely Benign-0.54Neutral0.004Benign0.006Benign2.87Benign0.22Tolerated3.6460.15400.3710122.6-18.03
c.2349G>C
M783I
2D
AIThe SynGAP1 missense variant M783I is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Consensus from multiple in‑silico predictors classifies the change as benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all return benign scores, and AlphaMissense‑Optimized also predicts a benign effect. No tool in the set indicates pathogenicity. The high‑accuracy assessments corroborate this view: AlphaMissense‑Optimized reports a benign outcome, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a Likely Benign classification, and Foldetta data are unavailable. Consequently, the aggregate evidence strongly supports a benign interpretation for M783I, and this conclusion does not conflict with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.736850Disordered0.738119Binding0.3310.8890.625-3.560Likely Benign0.418AmbiguousLikely Benign0.042Likely Benign-0.54Neutral0.004Benign0.006Benign2.87Benign0.22Tolerated3.6460.15400.3710122.6-18.03
c.2349G>T
M783I
2D
AIThe SynGAP1 missense variant M783I is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools uniformly indicate a benign effect. Benign calls are made by REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts pathogenicity; AlphaMissense‑Default remains uncertain. The high‑accuracy AlphaMissense‑Optimized score is benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports a likely benign outcome. Foldetta stability analysis is unavailable, so it does not influence the assessment. Overall, the computational evidence strongly supports a benign classification for M783I, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.736850Disordered0.738119Binding0.3310.8890.625-3.560Likely Benign0.418AmbiguousLikely Benign0.042Likely Benign-0.54Neutral0.004Benign0.006Benign2.87Benign0.22Tolerated3.6460.15400.3710122.6-18.03
c.3134C>A
A1045D
2D
AIThe SynGAP1 missense variant A1045D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that reach consensus all indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all score the variant as benign. AlphaMissense‑Optimized also predicts a benign outcome, whereas AlphaMissense‑Default remains uncertain. The SGM‑Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as “Likely Benign.” No tools predict pathogenicity. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the collective predictions strongly suggest that A1045D is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.975609Disordered0.948874Binding0.3520.8820.750-5.734Likely Benign0.418AmbiguousLikely Benign0.066Likely Benign-1.00Neutral0.411Benign0.172Benign2.64Benign0.16Tolerated0.19540.21020-2-5.344.01
c.3245A>G
Q1082R
2D
AIThe SynGAP1 missense variant Q1082R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.819762Disordered0.979325Binding0.3470.8960.875-3.584Likely Benign0.418AmbiguousLikely Benign0.076Likely Benign-0.96Neutral0.224Benign0.058Benign4.14Benign0.10Tolerated0.15900.301411-1.028.06
c.3379G>T
G1127W
2D
AIThe SynGAP1 missense variant G1127W is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33443931‑G‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized, whereas polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b all predict a pathogenic outcome; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields benign, and Foldetta’s protein‑folding stability result is unavailable. Overall, the balance of evidence, particularly from the high‑accuracy tools, indicates that the variant is most likely benign. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.899122Disordered0.852422Binding0.3440.9150.8756-33443931-G-T32.01e-6-9.850Likely Pathogenic0.418AmbiguousLikely Benign0.394Likely Benign-1.36Neutral0.983Probably Damaging0.665Possibly Damaging4.79Benign0.03Affected4.3240.07820.4032-2-7-0.5129.16
c.1752C>G
I584M
2D
3DClick to see structure in 3D Viewer
AISynGAP1 I584M is listed in ClinVar (ID 1301269) with an uncertain significance designation and is present in gnomAD (variant ID 6‑33440804‑C‑G). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, SIFT, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as likely pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) as benign. Overall, the majority of individual predictors lean toward a benign outcome, with two high‑accuracy tools supporting benign and one supporting pathogenic. Thus, the variant is most likely benign, which is consistent with its ClinVar uncertain status and does not contradict that classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.059222Structured0.046673Uncertain0.8460.2440.000Uncertain 36-33440804-C-G16.20e-7-10.119Likely Pathogenic0.419AmbiguousLikely Benign0.11Likely Benign0.10.46Likely Benign0.29Likely Benign1.16Destabilizing0.478Likely Benign-2.62Deleterious0.983Probably Damaging0.925Probably Damaging-1.25Pathogenic0.12Tolerated3.37340.07770.212721-2.618.03247.5-20.3-0.10.3-0.10.1XPotentially BenignA hydrophobic residue, Ile584, located in an α helix (res. Glu582-Met603), is swapped for another hydrophobic residue, Met584. The sec-butyl hydrocarbon side chain of Ile584 packs hydrophobically with residues in an inter-helix hydrophobic space (e.g., Leu588, Met477, Val473, and Ile483).In the variant simulations, the thioether hydrophobic side chain of Met584 maintains similar interactions as Ile584 in the WT, as it is roughly the same size and fits well within the hydrophobic space. Thus, the residue swap does not appear to cause any negative effects on the protein structure.
c.1903A>C
N635H
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant N635H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, Rosetta, Foldetta, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. Three tools (FoldX, premPS, AlphaMissense‑Default) give uncertain results. High‑accuracy methods give the following: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic; and Foldetta predicts benign. No prediction or folding‑stability result is missing or inconclusive. Based on the available evidence, the variant is most likely benign, and this assessment does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.039760Structured0.060246Uncertain0.9000.2520.000-12.507Likely Pathogenic0.419AmbiguousLikely Benign1.07Ambiguous0.2-0.10Likely Benign0.49Likely Benign0.91Ambiguous0.429Likely Benign-4.78Deleterious0.993Probably Damaging0.879Possibly Damaging2.90Benign0.00Affected0.11840.3720210.323.04
c.2602G>A
D868N
2D
AIThe SynGAP1 D868N missense variant has no ClinVar entry and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) predict a pathogenic outcome. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus likewise indicates Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar status, as none is currently assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.525368Disordered0.676362Binding0.2620.8150.250-3.052Likely Benign0.419AmbiguousLikely Benign0.161Likely Benign-2.01Neutral0.986Probably Damaging0.922Probably Damaging2.55Benign0.21Tolerated0.19770.7152210.0-0.98
c.2672T>G
L891R
2D
AIThe SynGAP1 missense variant L891R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus methods reinforce the benign assessment: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates “Likely Benign,” and the protein‑folding stability tool Foldetta has no available result for this variant. Based on the aggregate evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.712013Disordered0.505861Binding0.3050.9230.750-4.120Likely Benign0.419AmbiguousLikely Benign0.122Likely Benign-1.83Neutral0.970Probably Damaging0.801Possibly Damaging2.65Benign0.01Affected0.12330.0863-3-2-8.343.03
c.3220C>G
Q1074E
2D
AIThe SynGAP1 missense variant Q1074E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions strongly suggests that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.930790Disordered0.987006Binding0.3390.8970.750-2.815Likely Benign0.419AmbiguousLikely Benign0.096Likely Benign-0.79Neutral0.264Benign0.103Benign2.79Benign0.24Tolerated0.13860.2856220.00.98
c.3922C>A
R1308S
2D
AIThe SynGAP1 missense variant R1308S is not reported in ClinVar (ClinVar status: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. The high‑accuracy AlphaMissense‑Optimized predicts benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) predicts pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evaluated tools (five pathogenic vs. three benign) indicate a pathogenic effect. This prediction is not contradicted by ClinVar status, which has no entry for the variant. Thus, based on current computational evidence, the variant is most likely pathogenic.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.741537Disordered0.930652Binding0.3780.9040.750-2.180Likely Benign0.419AmbiguousLikely Benign0.307Likely Benign-3.76Deleterious0.982Probably Damaging0.982Probably Damaging2.36Pathogenic0.00Affected0.30700.47440-13.7-69.11
c.1045C>A
P349T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant P349T is not reported in ClinVar and is absent from gnomAD. Prediction tools that indicate a benign effect include REVEL, SIFT, and AlphaMissense‑Optimized. Those that predict a pathogenic effect comprise PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and the SGM‑Consensus score (which is derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Tools with inconclusive results are AlphaMissense‑Default, FoldX, Foldetta, and premPS. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as pathogenic, and Foldetta as uncertain. Overall, the majority of predictions lean toward pathogenicity, and this conclusion does not contradict any ClinVar annotation because no ClinVar status exists for this variant. Thus, the variant is most likely pathogenic based on the available computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicC20.167087Structured0.348607Uncertain0.9470.3960.000-9.736Likely Pathogenic0.420AmbiguousLikely Benign1.37Ambiguous0.12.56Destabilizing1.97Ambiguous0.76Ambiguous0.246Likely Benign-6.12Deleterious1.000Probably Damaging0.996Probably Damaging1.57Pathogenic0.07Tolerated0.16150.62380-10.93.99
c.1290G>A
M430I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M430I is catalogued in gnomAD (6‑33438195‑G‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, Foldetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the only inconclusive results come from FoldX, premPS, and AlphaMissense‑Default. High‑accuracy assessments reinforce the benign classification: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports “Likely Benign,” and Foldetta (combining FoldX‑MD and Rosetta outputs) also indicates benign. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.071867Structured0.385298Uncertain0.9520.3060.0006-33438195-G-A16.19e-7-4.655Likely Benign0.420AmbiguousLikely Benign1.22Ambiguous0.1-0.29Likely Benign0.47Likely Benign0.65Ambiguous0.068Likely Benign-1.62Neutral0.134Benign0.025Benign3.54Benign0.40Tolerated3.37290.15240.4116122.6-18.03
c.1290G>C
M430I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M430I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, Rosetta, Foldetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the remaining predictions (FoldX, premPS, AlphaMissense‑Default) are uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign; the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also classifies the variant as benign. Taken together, the consensus of both general and high‑accuracy predictors is that M430I is most likely benign, and this conclusion does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.071867Structured0.385298Uncertain0.9520.3060.000-4.655Likely Benign0.420AmbiguousLikely Benign1.22Ambiguous0.1-0.29Likely Benign0.47Likely Benign0.65Ambiguous0.068Likely Benign-1.62Neutral0.134Benign0.025Benign3.54Benign0.40Tolerated3.37290.15240.4116122.6-18.03
c.1290G>T
M430I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M430I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, Rosetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome. Predictions that are inconclusive are FoldX, premPS, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, while Foldetta’s combined FoldX‑MD/Rosetta output is unavailable due to the uncertain FoldX result. Overall, the evidence overwhelmingly supports a benign classification for M430I, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.071867Structured0.385298Uncertain0.9520.3060.000-4.655Likely Benign0.420AmbiguousLikely Benign1.22Ambiguous0.1-0.29Likely Benign0.47Likely Benign0.65Ambiguous0.068Likely Benign-1.62Neutral0.134Benign0.025Benign3.54Benign0.40Tolerated3.37290.15240.4116122.6-18.03
c.2723A>T
Q908L
2D
AIThe SynGAP1 missense variant Q908L is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT uniformly predict a pathogenic impact. AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus is Likely Benign, and Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.608892Disordered0.678728Binding0.2750.9170.250-3.589Likely Benign0.420AmbiguousLikely Benign0.193Likely Benign-1.40Neutral0.985Probably Damaging0.982Probably Damaging2.53Benign0.05Affected0.07060.5655-2-27.3-14.97
c.3086A>G
Q1029R
2D
AIThe SynGAP1 missense variant Q1029R has no ClinVar entry and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (both HumDiv and HumVar) predict a pathogenic outcome. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign; Foldetta results are unavailable. Based on the preponderance of evidence from both general and high‑accuracy predictors, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.995643Binding0.3750.7340.500-3.437Likely Benign0.420AmbiguousLikely Benign0.073Likely Benign-0.72Neutral0.961Probably Damaging0.677Possibly Damaging2.73Benign0.88Tolerated0.13770.242011-1.028.06
c.3392C>T
P1131L
2D
AIThe SynGAP1 missense variant P1131L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. Tools that predict a pathogenic effect are PROVEAN and SIFT, while AlphaMissense‑Default remains uncertain. The high‑accuracy AlphaMissense‑Optimized tool classifies the variant as benign. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also yields a benign prediction (2 benign vs. 1 pathogenic, with one uncertain). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this assessment does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.919029Disordered0.855155Binding0.3600.8990.750-5.267Likely Benign0.420AmbiguousLikely Benign0.293Likely Benign-3.62Deleterious0.002Benign0.005Benign5.26Benign0.00Affected0.20430.6998-3-35.416.04
c.1669T>G
S557A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S557A is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include AlphaMissense‑Optimized and Rosetta, whereas a majority of tools (REVEL, SIFT, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and the SGM‑Consensus) predict a pathogenic impact. Uncertain or inconclusive results come from AlphaMissense‑Default, FoldX, Foldetta, and premPS. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the preponderance of evidence points to a pathogenic effect. This conclusion is not contradicted by ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.028107Structured0.010261Uncertain0.9240.2150.000-11.044Likely Pathogenic0.421AmbiguousLikely Benign1.26Ambiguous0.00.09Likely Benign0.68Ambiguous0.54Ambiguous0.801Likely Pathogenic-2.70Deleterious0.944Possibly Damaging0.987Probably Damaging-1.69Pathogenic0.05Affected0.46950.4836112.6-16.00
c.1826G>A
G609E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G609E has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include PROVEAN, SIFT, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are REVEL, FoldX, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. The remaining tools (Rosetta, Foldetta, premPS, AlphaMissense‑Default) give uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the majority of evidence points to a pathogenic impact, and this conclusion is not contradicted by any ClinVar annotation. Thus, the variant is most likely pathogenic.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.179055Structured0.203786Uncertain0.8510.2520.000-10.470Likely Pathogenic0.421AmbiguousLikely Benign2.95Destabilizing0.4-1.65Ambiguous0.65Ambiguous0.61Ambiguous0.531Likely Pathogenic-2.28Neutral0.916Possibly Damaging0.588Possibly Damaging-1.41Pathogenic0.17Tolerated0.17090.44910-2-3.172.06
c.2005A>C
N669H
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant N669H has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. Remaining tools (FoldX, Rosetta, Foldetta, premPS, AlphaMissense‑Default) are uncertain and are treated as unavailable. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the majority of evidence points toward a pathogenic impact, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.142424Structured0.086615Uncertain0.8720.3800.000-10.364Likely Pathogenic0.421AmbiguousLikely Benign1.26Ambiguous0.21.69Ambiguous1.48Ambiguous0.80Ambiguous0.432Likely Benign-4.49Deleterious0.999Probably Damaging0.993Probably Damaging3.35Benign0.01Affected0.17320.4839210.323.04
c.2111G>A
S704N
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S704N is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33441370‑G‑A). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while premPS and AlphaMissense‑Default are inconclusive. High‑accuracy assessments reinforce the benign interpretation: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is “Likely Benign”; and Foldetta (combining FoldX‑MD and Rosetta outputs) is benign. Overall, the majority of evidence points to a benign effect, which does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.096677Structured0.383620Uncertain0.9280.3630.000Conflicting 46-33441370-G-A271.67e-5-5.917Likely Benign0.421AmbiguousLikely Benign0.48Likely Benign0.1-0.12Likely Benign0.18Likely Benign0.54Ambiguous0.058Likely Benign-0.49Neutral0.771Possibly Damaging0.275Benign3.39Benign0.08Tolerated3.47100.09110.375411-2.727.03233.2-29.1-0.10.0-0.10.1XPotentially BenignSer704 is located at the end and outer surface of an α-helix (res. Thr704-Gly712), which is connected via a tight turn or loop to another α-helix (res. Asp684-Gln702). The hydroxyl side chain of Ser704 occasionally forms a hydrogen bond with the amide group of Ala707. However, in the variant simulations, the carboxamide side chain of Asn704 achieves more lasting and numerous hydrogen-bonding interactions with the residues at the helix end, such as Glu706, Ala707, and Leu708. Consequently, the residue swap could strengthen the α-helix secondary structure integrity at the helix end, which could have either positive or negative effects on its function.
c.2332A>T
N778Y
2D
AIThe SynGAP1 missense variant N778Y is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster into two groups: benign (REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized) and pathogenic (polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT). AlphaMissense‑Default is uncertain, while the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, indicates a likely benign effect. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, SGM‑Consensus is likely benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Taken together, the preponderance of evidence from both general and high‑accuracy predictors points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing clinical classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.494003Structured0.853922Binding0.2880.8870.500-5.723Likely Benign0.421AmbiguousLikely Benign0.175Likely Benign-2.48Neutral0.991Probably Damaging0.980Probably Damaging4.16Benign0.02Affected0.05890.6139-2-22.249.07
c.3922C>T
R1308C
2D
AIThe SynGAP1 missense variant R1308C is listed in ClinVar with an “Uncertain” significance and is present in the gnomAD database (ID 6‑33451796‑C‑T). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default remains uncertain. The high‑accuracy consensus (SGM Consensus) derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN yields a pathogenic verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a pathogenic impact, and this assessment does not contradict the current ClinVar “Uncertain” status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.741537Disordered0.930652Binding0.3780.9040.750Conflicting 26-33451796-C-T42.48e-6-4.994Likely Benign0.421AmbiguousLikely Benign0.352Likely Benign-4.89Deleterious0.999Probably Damaging0.993Probably Damaging2.31Pathogenic0.00Affected3.7750.31390.4274-4-37.0-53.05
c.2134G>A
G712S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G712S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic impact comprise FoldX, Rosetta, Foldetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), and SIFT. Uncertain results come from premPS, ESM1b, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as pathogenic, and the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive and therefore unavailable. Overall, the majority of evidence points to a pathogenic effect for G712S. This conclusion does not contradict ClinVar, which has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.278302Structured0.384858Uncertain0.9470.3650.000-7.942In-Between0.422AmbiguousLikely Benign2.30Destabilizing0.14.79Destabilizing3.55Destabilizing0.62Ambiguous0.282Likely Benign-4.84Deleterious1.000Probably Damaging0.998Probably Damaging3.42Benign0.02Affected0.28620.450110-0.430.03
c.2306T>A
L769H
2D
AIThe SynGAP1 missense variant L769H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, all of which classify the variant as benign. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT, all of which report the variant as pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.411940Structured0.928432Binding0.3670.8830.250-6.038Likely Benign0.422AmbiguousLikely Benign0.235Likely Benign-1.96Neutral0.977Probably Damaging0.721Possibly Damaging3.90Benign0.00Affected0.10160.0828-2-3-7.023.98
c.237C>A
N79K
2D
AIThe SynGAP1 missense variant N79K is listed in gnomAD (ID 6‑33425845‑C‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized scores benign and the SGM‑Consensus indicates “Likely Benign.” No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the preponderance of evidence points to a benign effect for the variant, and this conclusion is not contradicted by any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.618285Disordered0.457064Uncertain0.2900.8760.3756-33425845-C-A16.20e-7-2.811Likely Benign0.422AmbiguousLikely Benign0.030Likely Benign-0.91Neutral0.001Benign0.000Benign4.22Benign0.00Affected4.3210.18830.392901-0.414.07
c.237C>G
N79K
2D
AIThe SynGAP1 missense variant N79K is listed in gnomAD (ID 6‑33425845‑C‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact. There is no ClinVar classification to contradict this conclusion. Thus, based on current predictions, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.618285Disordered0.457064Uncertain0.2900.8760.3756-33425845-C-G16.20e-7-2.811Likely Benign0.422AmbiguousLikely Benign0.030Likely Benign-0.91Neutral0.001Benign0.000Benign4.22Benign0.00Affected4.3210.18830.392901-0.414.07
c.2597T>A
V866E
2D
AIThe SynGAP1 missense variant V866E is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT uniformly predict a pathogenic impact. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence—including the SGM consensus and AlphaMissense‑Optimized—points to a benign effect, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.599170Disordered0.638070Binding0.2660.7880.250-3.917Likely Benign0.422AmbiguousLikely Benign0.157Likely Benign-2.09Neutral0.998Probably Damaging0.939Probably Damaging2.72Benign0.05Affected0.09960.1629-2-2-7.729.98
c.2657C>A
A886E
2D
AIThe SynGAP1 missense variant A886E is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors a benign outcome. Foldetta, which would provide a protein‑folding stability estimate, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, which contains no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.716283Disordered0.619166Binding0.3590.9220.500-3.747Likely Benign0.422AmbiguousLikely Benign0.096Likely Benign-1.31Neutral0.423Benign0.230Benign2.17Pathogenic0.00Affected0.14830.20080-1-5.358.04
c.3290C>G
P1097R
2D
AIThe SynGAP1 missense variant P1097R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Based on the preponderance of benign predictions and the lack of pathogenic evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.974957Binding0.3840.8581.000-4.938Likely Benign0.422AmbiguousLikely Benign0.079Likely Benign-1.75Neutral0.918Possibly Damaging0.525Possibly Damaging2.58Benign0.07Tolerated0.15170.40270-2-2.959.07
c.3380G>A
G1127E
2D
AIThe SynGAP1 missense variant G1127E is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the remaining tools (ESM1b and AlphaMissense‑Default) are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a tie between benign and uncertain calls. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the evidence strongly points to a benign effect, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.899122Disordered0.852422Binding0.3440.9150.875-7.359In-Between0.422AmbiguousLikely Benign0.314Likely Benign-0.56Neutral0.224Benign0.091Benign4.88Benign0.15Tolerated0.13950.42440-2-3.172.06
c.818A>C
E273A
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant E273A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Prediction tools that classify the variant as benign include REVEL, FoldX, Rosetta, Foldetta, premPS, and AlphaMissense‑Optimized. Those that predict pathogenicity are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM; AlphaMissense‑Default is uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates Likely Pathogenic, whereas AlphaMissense‑Optimized predicts Benign and Foldetta (combining FoldX‑MD and Rosetta) predicts Benign. Overall, the majority of individual tools are split evenly, but the two high‑accuracy methods favor a benign effect. Thus, the variant is most likely benign based on current computational predictions, and this assessment does not contradict any ClinVar annotation because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicC20.071867Structured0.398918Uncertain0.8630.1960.125-8.851Likely Pathogenic0.422AmbiguousLikely Benign0.29Likely Benign0.2-0.29Likely Benign0.00Likely Benign0.16Likely Benign0.240Likely Benign-3.61Deleterious0.896Possibly Damaging0.492Possibly Damaging1.73Pathogenic0.04Affected0.31600.36150-15.3-58.04
c.899C>A
S300Y
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S300Y has no ClinVar entry and is not reported in gnomAD. Prediction tools cluster into two groups: benign predictions come from REVEL, FoldX, Foldetta, premPS, and AlphaMissense‑Optimized; pathogenic predictions come from SGM‑Consensus, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. Two tools (AlphaMissense‑Default and Rosetta) are uncertain and do not influence the consensus. High‑accuracy methods give the following results: AlphaMissense‑Optimized predicts benign; SGM‑Consensus (a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) predicts likely pathogenic; Foldetta (combining FoldX‑MD and Rosetta outputs) predicts benign. Overall, the majority of evidence points toward a pathogenic effect, and this assessment does not contradict any ClinVar status (none is available). Thus, based on current predictions, the variant is most likely pathogenic.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicC20.356642Structured0.256848Uncertain0.7420.2800.375-10.464Likely Pathogenic0.422AmbiguousLikely Benign-0.08Likely Benign0.40.55Ambiguous0.24Likely Benign0.28Likely Benign0.116Likely Benign-2.52Deleterious0.975Probably Damaging0.686Possibly Damaging1.52Pathogenic0.01Affected0.06780.5395-3-2-0.576.10
c.1853A>T
Q618L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q618L is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, SIFT, and polyPhen‑2 HumVar, while those that predict a pathogenic effect are SGM‑Consensus (Likely Pathogenic), PROVEAN, polyPhen‑2 HumDiv, ESM1b, and FATHMM. AlphaMissense‑Default is uncertain, whereas AlphaMissense‑Optimized predicts benign. High‑accuracy methods give the following results: AlphaMissense‑Optimized – benign; SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) – Likely Pathogenic; Foldetta – benign. Overall, the majority of tools (nine benign vs. five pathogenic) predict a benign impact. Thus, the variant is most likely benign based on current predictions, and this assessment does not contradict the ClinVar status, which is currently unreported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.175930Structured0.138725Uncertain0.9040.2400.000-8.561Likely Pathogenic0.423AmbiguousLikely Benign-0.07Likely Benign0.10.20Likely Benign0.07Likely Benign0.31Likely Benign0.479Likely Benign-3.94Deleterious0.712Possibly Damaging0.268Benign-1.28Pathogenic0.09Tolerated0.06120.4146-2-27.3-14.97
c.2110A>T
S704C
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S704C is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. High‑accuracy assessments give a mixed picture: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) is uncertain. Other stability‑based tools such as FoldX, Rosetta, and premPS also return uncertain results. Overall, the majority of individual predictors lean toward pathogenicity, and the high‑accuracy consensus also supports a pathogenic classification. Thus, the variant is most likely pathogenic, and this assessment does not contradict any ClinVar status (none available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.096677Structured0.383620Uncertain0.9280.3630.000-10.438Likely Pathogenic0.423AmbiguousLikely Benign1.56Ambiguous0.10.98Ambiguous1.27Ambiguous0.52Ambiguous0.251Likely Benign-3.52Deleterious0.997Probably Damaging0.789Possibly Damaging3.40Benign0.01Affected0.07890.46120-13.316.06
c.2049C>G
I683M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 I683M variant is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, FATHMM, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. The remaining tools (FoldX, Rosetta, Foldetta, premPS, AlphaMissense‑Default) give uncertain or inconclusive results and are treated as unavailable evidence. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the majority of definitive predictions (five pathogenic vs. three benign) point to a pathogenic impact. Thus, the variant is most likely pathogenic, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.200174Structured0.143268Uncertain0.8480.3140.000-9.010Likely Pathogenic0.424AmbiguousLikely Benign0.69Ambiguous0.10.68Ambiguous0.69Ambiguous0.74Ambiguous0.296Likely Benign-2.88Deleterious0.999Probably Damaging0.986Probably Damaging3.30Benign0.01Affected0.09330.266221-2.618.03
c.2401G>C
G801R
2D
AIThe SynGAP1 missense variant G801R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The high‑accuracy AlphaMissense‑Optimized score is benign, and the SGM‑Consensus also indicates a benign outcome; Foldetta data are not available. Overall, the majority of evidence points to a benign effect, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.874069Disordered0.636323Binding0.3200.8920.625-4.226Likely Benign0.424AmbiguousLikely Benign0.045Likely Benign-0.18Neutral0.846Possibly Damaging0.624Possibly Damaging2.73Benign0.64Tolerated0.08500.3793-3-2-4.199.14
c.2981A>T
K994M
2D
AIThe SynGAP1 missense variant K994M is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign. Pathogenicity is suggested only by polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus (SGM‑Consensus) classifies the variant as likely benign, and AlphaMissense‑Optimized also predicts benign. No Foldetta stability analysis is available. Overall, the majority of evidence points to a benign impact, and this assessment does not conflict with ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.930054Binding0.2890.9120.750-2.974Likely Benign0.424AmbiguousLikely Benign0.057Likely Benign-1.21Neutral0.589Possibly Damaging0.187Benign4.04Benign0.00Affected0.16120.43950-15.83.02
c.3088C>G
H1030D
2D
AIThe SynGAP1 missense variant H1030D is reported in gnomAD (variant ID 6‑33443640‑C‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all predict benign. Only SIFT predicts a pathogenic effect, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence indicates the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.849326Disordered0.995856Binding0.3750.7350.5006-33443640-C-G16.19e-7-3.500Likely Benign0.424AmbiguousLikely Benign0.189Likely Benign-0.85Neutral0.126Benign0.066Benign2.78Benign0.05Affected3.7750.22730.2422-11-0.3-22.05
c.74G>C
R25P
2D
AIThe SynGAP1 missense variant R25P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT uniformly predict a pathogenic outcome. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.461924Structured0.438941Uncertain0.3730.8900.375-3.394Likely Benign0.424AmbiguousLikely Benign0.155Likely Benign-1.56Neutral0.841Possibly Damaging0.809Possibly Damaging3.94Benign0.00Affected0.22170.45710-22.9-59.07
c.181G>A
E61K
2D
AIThe SynGAP1 E61K missense variant has no ClinVar entry and is not reported in gnomAD. Functional prediction tools cluster into two consensus groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the aggregate evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.352862Structured0.477329Uncertain0.5180.6990.125-4.953Likely Benign0.425AmbiguousLikely Benign0.120Likely Benign-0.22Neutral0.458Possibly Damaging0.678Possibly Damaging4.34Benign0.00Affected0.27360.569101-0.4-0.94
c.278G>T
R93L
2D
AIThe SynGAP1 R93L missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus indicates Likely Benign, and Foldetta results are unavailable. Overall, the preponderance of evidence points to the variant being most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.549151Binding0.2900.8740.625-2.850Likely Benign0.425AmbiguousLikely Benign0.064Likely Benign-1.72Neutral0.103Benign0.019Benign4.00Benign0.00Affected0.21970.4861-3-28.3-43.03
c.2961C>A
D987E
2D
AIThe SynGAP1 missense variant D987E is reported in gnomAD (6‑33443513‑C‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of predictions points to a benign effect, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.823549Disordered0.919118Binding0.2990.9030.7506-33443513-C-A16.20e-7-4.406Likely Benign0.425AmbiguousLikely Benign0.124Likely Benign-1.36Neutral0.049Benign0.044Benign2.64Benign0.04Affected4.3220.15860.7239230.014.03
c.2961C>G
D987E
2D
AIThe SynGAP1 missense variant D987E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus indicates Likely Benign, and Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign effect for D987E, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.823549Disordered0.919118Binding0.2990.9030.750-4.406Likely Benign0.425AmbiguousLikely Benign0.124Likely Benign-1.36Neutral0.049Benign0.044Benign2.64Benign0.04Affected4.3220.15860.7239230.014.03
c.3281C>G
S1094C
2D
AIThe SynGAP1 missense variant S1094C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. Two tools—AlphaMissense‑Default and ESM1b—return uncertain results. High‑accuracy assessments are limited: AlphaMissense‑Optimized indicates a benign effect; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields no clear consensus and is treated as unavailable; Foldetta data are not provided, so its stability prediction is also unavailable. Overall, the balance of evidence favors a pathogenic interpretation, and this conclusion does not conflict with the absence of a ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.938133Disordered0.981352Binding0.3580.8771.000-7.143In-Between0.425AmbiguousLikely Benign0.131Likely Benign-1.81Neutral0.997Probably Damaging0.946Probably Damaging2.45Pathogenic0.05Affected0.14030.63090-13.316.06
c.3314G>C
R1105P
2D
AIThe SynGAP1 missense variant R1105P is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) leans pathogenic. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of predictions (six benign vs. two pathogenic) suggest a benign impact, and this conclusion does not contradict the lack of ClinVar annotation. Thus, the variant is most likely benign based on current predictive evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.901269Disordered0.954396Binding0.3300.8630.875-3.325Likely Benign0.425AmbiguousLikely Benign0.149Likely Benign-3.22Deleterious0.007Benign0.006Benign2.44Pathogenic0.08Tolerated0.20310.51010-22.9-59.07
c.1468G>T
A490S
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant A490S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include AlphaMissense‑Optimized, whereas the majority of other in silico predictors (SGM‑Consensus, REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM) indicate a pathogenic impact. High‑accuracy assessments further support this: AlphaMissense‑Optimized classifies the variant as benign, SGM‑Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) predicts it to be likely pathogenic, and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, yields an inconclusive result. No other tools provide definitive evidence. Overall, the preponderance of pathogenic predictions suggests that A490S is most likely pathogenic, and this assessment does not contradict the current ClinVar status, which has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.120615Structured0.322979Uncertain0.9380.2100.125-8.307Likely Pathogenic0.426AmbiguousLikely Benign0.76Ambiguous0.11.55Ambiguous1.16Ambiguous0.89Ambiguous0.766Likely Pathogenic-2.82Deleterious0.983Probably Damaging0.993Probably Damaging-1.41Pathogenic0.02Affected0.23380.311611-2.616.00
c.2096T>C
V699A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V699A has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while premPS, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar predict a pathogenic impact. Tools with inconclusive results are FoldX, Rosetta, Foldetta, and AlphaMissense‑Default. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is Benign, and the high‑accuracy AlphaMissense‑Optimized also reports Benign. Foldetta, which integrates FoldX‑MD and Rosetta outputs, is Uncertain. Overall, the majority of evidence points to a benign effect, and this assessment does not contradict any ClinVar annotation because none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.069024Structured0.432975Uncertain0.9350.3150.000-6.017Likely Benign0.426AmbiguousLikely Benign1.37Ambiguous0.01.30Ambiguous1.34Ambiguous1.21Destabilizing0.236Likely Benign-2.39Neutral0.861Possibly Damaging0.625Possibly Damaging3.42Benign0.54Tolerated0.24500.212400-2.4-28.05
c.2179A>T
N727Y
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant N727Y has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, Foldetta, premPS, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. Two tools remain inconclusive: AlphaMissense‑Default and Rosetta. Separately, the high‑accuracy methods give the following results: AlphaMissense‑Optimized predicts benign; the SGM Consensus (a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports Likely Pathogenic; and Foldetta, which integrates FoldX‑MD and Rosetta outputs, predicts benign. Overall, the majority of individual predictors and the SGM Consensus lean toward a pathogenic interpretation, while the high‑accuracy folding‑stability assessment is benign. Thus, the variant is most likely pathogenic based on the available predictions, and this assessment does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.538167Disordered0.442107Uncertain0.8430.5420.625-10.106Likely Pathogenic0.426AmbiguousLikely Benign-0.12Likely Benign0.1-0.52Ambiguous-0.32Likely Benign0.35Likely Benign0.347Likely Benign-5.34Deleterious1.000Probably Damaging0.998Probably Damaging2.12Pathogenic0.02Affected0.05630.6091-2-22.249.07
c.2527A>C
M843L
2D
AIThe SynGAP1 missense variant M843L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is classified as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Based on the preponderance of benign predictions and the lack of pathogenic evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.585406Disordered0.617934Binding0.3270.8540.375-4.406Likely Benign0.426AmbiguousLikely Benign0.181Likely Benign-1.02Neutral0.699Possibly Damaging0.833Possibly Damaging2.92Benign0.33Tolerated0.17170.4571421.9-18.03
c.2527A>T
M843L
2D
AIThe SynGAP1 missense variant M843L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.585406Disordered0.617934Binding0.3270.8540.375-4.406Likely Benign0.426AmbiguousLikely Benign0.181Likely Benign-1.02Neutral0.699Possibly Damaging0.833Possibly Damaging2.92Benign0.33Tolerated0.17170.4571421.9-18.03
c.3103C>A
P1035T
2D
AIThe SynGAP1 missense variant P1035T is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default remains uncertain, and no Foldetta stability assessment is available. High‑accuracy evidence from AlphaMissense‑Optimized and the SGM‑Consensus both support a benign classification, while the absence of a Foldetta result does not alter this view. Overall, the majority of predictions indicate a benign effect, and this is consistent with the ClinVar “Uncertain” designation rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.945666Disordered0.989572Binding0.3000.7560.625Uncertain 1-4.447Likely Benign0.426AmbiguousLikely Benign0.087Likely Benign-0.96Neutral0.901Possibly Damaging0.537Possibly Damaging2.72Benign0.23Tolerated3.7750.16280.72200-10.93.99
c.4A>C
S2R
2D
AIThe SynGAP1 missense variant S2R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from both general and high‑accuracy predictors indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.543646Binding0.3820.9220.750-3.684Likely Benign0.426AmbiguousLikely Benign0.062Likely Benign-0.44Neutral0.117Benign0.008Benign4.05Benign0.00Affected4.3210.09960.4503-10-3.769.11
c.6C>A
S2R
2D
AIThe SynGAP1 missense variant S2R is present in gnomAD (ID 6‑33420270‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score all report benign or likely benign. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors benign. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.543646Binding0.3820.9220.7506-33420270-C-A16.52e-7-3.684Likely Benign0.426AmbiguousLikely Benign0.070Likely Benign-0.44Neutral0.117Benign0.008Benign4.05Benign0.00Affected4.3210.09960.4503-10-3.769.11
c.6C>G
S2R
2D
AIThe SynGAP1 missense variant S2R is not reported in ClinVar (ClinVar ID None) and has no entry in gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its status is unavailable. Overall, the preponderance of evidence from multiple prediction tools and high‑accuracy methods indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.543646Binding0.3820.9220.750-3.684Likely Benign0.426AmbiguousLikely Benign0.065Likely Benign-0.44Neutral0.117Benign0.008Benign4.05Benign0.00Affected4.3210.09960.4503-10-3.769.11
c.2248G>T
G750W
2D
AIThe SynGAP1 missense variant G750W is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL and AlphaMissense‑Optimized, while the majority of tools predict a pathogenic impact: PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all classify the variant as damaging. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as Likely Pathogenic. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus as pathogenic, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) is unavailable for this variant. Overall, the preponderance of evidence from multiple in silico predictors indicates that G750W is most likely pathogenic, and this assessment does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.618285Disordered0.646832Binding0.3480.8660.625-8.433Likely Pathogenic0.427AmbiguousLikely Benign0.135Likely Benign-3.30Deleterious1.000Probably Damaging0.994Probably Damaging2.41Pathogenic0.00Affected0.07380.4009-7-2-0.5129.16
c.2281C>G
R761G
2D
AIThe SynGAP1 missense variant R761G is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in silico predictors indicates a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all score it as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also classifies it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default tool remains uncertain, and no Foldetta stability assessment is available. High‑accuracy methods reinforce the benign prediction: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign, with no contradictory Foldetta data. Overall, the majority of evidence supports a benign classification, and this is consistent with the lack of ClinVar annotation; there is no conflict with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.538167Disordered0.900613Binding0.3530.8650.250-4.453Likely Benign0.427AmbiguousLikely Benign0.220Likely Benign-2.07Neutral0.992Probably Damaging0.900Possibly Damaging2.70Benign0.83Tolerated0.33330.3217-3-24.1-99.14
c.2414T>A
L805Q
2D
AIThe SynGAP1 missense variant L805Q is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools cluster into two groups: benign predictions come from REVEL, ESM1b, and AlphaMissense‑Optimized, while pathogenic predictions arise from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. AlphaMissense‑Default remains uncertain. High‑accuracy assessments further clarify the picture: AlphaMissense‑Optimized predicts a benign effect, whereas the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—leans pathogenic (2 pathogenic vs. 1 benign, 1 uncertain). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the balance of evidence (five pathogenic vs. three benign predictions, with a pathogenic SGM Consensus) indicates that the variant is most likely pathogenic, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.775545Disordered0.827669Binding0.3410.9030.625-6.244Likely Benign0.427AmbiguousLikely Benign0.152Likely Benign-2.66Deleterious0.927Possibly Damaging0.690Possibly Damaging2.37Pathogenic0.00Affected0.12150.1265-2-2-7.314.97
c.967C>A
L323M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 L323M missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, PROVEAN, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. The remaining tools—Foldetta, premPS, AlphaMissense‑Default, ESM1b, and Rosetta—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive, and Foldetta is also inconclusive. Taken together, the evidence leans toward a benign impact for the variant, and this assessment does not contradict any ClinVar annotation, as none exists for this change.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.268042Structured0.428564Uncertain0.9560.3690.000-7.065In-Between0.427AmbiguousLikely Benign0.11Likely Benign0.11.82Ambiguous0.97Ambiguous0.93Ambiguous0.270Likely Benign-1.02Neutral0.997Probably Damaging0.939Probably Damaging0.64Pathogenic0.03Affected0.06370.301042-1.918.03
c.137C>A
P46H
2D
AIThe SynGAP1 missense variant P46H is evaluated by multiple in silico tools. Consensus from SGM‑Consensus indicates a likely benign effect, and the variant is not reported in ClinVar or gnomAD. Functional predictors that agree on a benign outcome include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Predictors that flag a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports likely benign, while Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact for P46H, and this conclusion is not contradicted by any ClinVar annotation. The variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.390993Structured0.433588Uncertain0.5490.7410.375-4.022Likely Benign0.428AmbiguousLikely Benign0.097Likely Benign-0.43Neutral0.992Probably Damaging0.977Probably Damaging4.10Benign0.00Affected0.23600.52290-2-1.640.02
c.3024T>A
D1008E
2D
AIThe SynGAP1 D1008E missense variant is catalogued in gnomAD (6‑33443576‑T‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). In contrast, polyPhen‑2 HumDiv and HumVar both predict a pathogenic outcome. AlphaMissense‑Default remains uncertain, providing no definitive signal. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus also reports it as likely benign. No Foldetta stability analysis is available, so it does not influence the overall assessment. Based on the preponderance of evidence from both general and high‑accuracy predictors, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.694846Disordered0.919416Binding0.2800.8990.6256-33443576-T-A16.20e-7-2.809Likely Benign0.428AmbiguousLikely Benign0.151Likely Benign-0.53Neutral0.997Probably Damaging0.994Probably Damaging2.93Benign1.00Tolerated3.7750.23150.6303230.014.03
c.3024T>G
D1008E
2D
AIThe SynGAP1 missense variant D1008E is listed in gnomAD (ID 6‑33443576‑T‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and Foldetta results are unavailable. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta provides no data. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.694846Disordered0.919416Binding0.2800.8990.6256-33443576-T-G-2.809Likely Benign0.428AmbiguousLikely Benign0.151Likely Benign-0.53Neutral0.997Probably Damaging0.994Probably Damaging2.93Benign1.00Tolerated3.7750.23150.6303230.014.03
c.31G>A
G11R
2D
AIThe SynGAP1 missense variant G11R is catalogued in gnomAD (ID 6‑33420295‑G‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions come from polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.444081Structured0.501027Binding0.3480.9150.3756-33420295-G-A-3.418Likely Benign0.428AmbiguousLikely Benign0.102Likely Benign-0.47Neutral0.498Possibly Damaging0.026Benign3.92Benign0.00Affected4.3210.10220.4596-2-3-4.199.14
c.31G>C
G11R
2D
AIThe SynGAP1 missense variant G11R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.444081Structured0.501027Binding0.3480.9150.375-3.418Likely Benign0.428AmbiguousLikely Benign0.109Likely Benign-0.47Neutral0.498Possibly Damaging0.026Benign3.92Benign0.00Affected4.3210.10220.4596-2-3-4.199.14
c.2449T>G
S817A
2D
AIThe SynGAP1 missense variant S817A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also resolves to benign, while Foldetta results are unavailable. Overall, the majority of high‑confidence predictions indicate a benign impact. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.490133Structured0.727082Binding0.3140.9010.625-6.321Likely Benign0.429AmbiguousLikely Benign0.116Likely Benign-1.86Neutral0.977Probably Damaging0.846Possibly Damaging2.45Pathogenic0.00Affected0.52070.5866Strenghten112.6-16.00
c.2492A>C
E831A
2D
AIThe SynGAP1 missense variant E831A is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, SIFT, polyPhen‑2 HumVar, and ESM1b, while pathogenic predictions come from PROVEAN, polyPhen‑2 HumDiv, and FATHMM. AlphaMissense‑Default is uncertain, whereas AlphaMissense‑Optimized predicts benign. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a pathogenic verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. High‑accuracy tools therefore give conflicting signals: AlphaMissense‑Optimized benign versus SGM Consensus pathogenic, with no Foldetta data. Overall, the bulk of predictions lean toward a benign effect, and this assessment does not contradict the absence of a ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.626927Disordered0.617732Binding0.3190.8740.375-4.780Likely Benign0.429AmbiguousLikely Benign0.115Likely Benign-2.56Deleterious0.625Possibly Damaging0.315Benign2.36Pathogenic0.07Tolerated0.38450.68680-15.3-58.04
c.2568C>A
N856K
2D
AIThe SynGAP1 missense variant N856K is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority of high‑accuracy predictors (AlphaMissense‑Optimized and the SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also support a benign classification. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact, but these are the only tools in disagreement. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. Overall, the preponderance of evidence points to a benign effect for N856K, and this conclusion is not in conflict with any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.637480Disordered0.477615Uncertain0.2630.8270.500-3.511Likely Benign0.429AmbiguousLikely Benign0.079Likely Benign-1.51Neutral0.965Probably Damaging0.721Possibly Damaging4.19Benign0.26Tolerated0.20650.625210-0.414.07
c.2568C>G
N856K
2D
AIThe SynGAP1 missense variant N856K is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority of high‑accuracy predictors—AlphaMissense‑Optimized and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN)—also support a benign classification. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact, but these are the only tools in disagreement. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the preponderance of evidence points to a benign effect for N856K, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.637480Disordered0.477615Uncertain0.2630.8270.500-3.511Likely Benign0.429AmbiguousLikely Benign0.079Likely Benign-1.51Neutral0.965Probably Damaging0.721Possibly Damaging4.19Benign0.26Tolerated0.20650.625210-0.414.07
c.3295T>G
Y1099D
2D
AIThe SynGAP1 missense variant Y1099D is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in‑silico predictors indicates a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all score the change as tolerated or benign, while only polyPhen‑2 HumDiv flags it as pathogenic. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, SGM‑Consensus is Likely Benign, and Foldetta results are unavailable. Taken together, the majority of evidence points to a benign impact. This conclusion is consistent with the absence of a ClinVar assertion, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.885302Disordered0.974267Binding0.4000.8621.000-4.193Likely Benign0.429AmbiguousLikely Benign0.130Likely Benign-1.08Neutral0.818Possibly Damaging0.435Benign2.79Benign0.13Tolerated0.38190.0935-4-3-2.2-48.09
c.208C>G
R70G
2D
AIThe SynGAP1 missense variant R70G is listed in gnomAD (ID 6‑33425816‑C‑G) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions come from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default is uncertain, and Foldetta (FoldX‑MD/Rosetta stability assessment) has no result for this variant. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also indicates a likely benign outcome; Foldetta data are unavailable. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.458981Uncertain0.3920.7930.3756-33425816-C-G16.20e-7-3.555Likely Benign0.430AmbiguousLikely Benign0.095Likely Benign-0.61Neutral0.962Probably Damaging0.726Possibly Damaging4.11Benign0.00Affected4.3210.30780.3194-2-34.1-99.14
c.214C>T
R72W
2D
AIThe SynGAP1 missense variant R72W is catalogued in gnomAD (ID 6‑33425822‑C‑T) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions are reported by polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign trend: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus also indicates a likely benign outcome. The Foldetta stability analysis is unavailable, providing no additional evidence. Overall, the preponderance of computational evidence points to a benign effect for R72W, and this conclusion is not contradicted by any ClinVar classification (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.497853Structured0.455349Uncertain0.3550.8190.3756-33425822-C-T16.20e-7-5.546Likely Benign0.430AmbiguousLikely Benign0.145Likely Benign-1.82Neutral0.994Probably Damaging0.689Possibly Damaging4.07Benign0.00Affected4.3210.16010.3652-323.630.03
c.2720G>A
S907N
2D
AIThe SynGAP1 missense variant S907N is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority‑vote SGM‑Consensus also reports a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy evaluations further support a benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is likely benign, with no Foldetta data to contradict this. Overall, the preponderance of evidence points to a benign effect, and this assessment does not conflict with any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.637480Disordered0.661854Binding0.3360.9200.250-4.520Likely Benign0.430AmbiguousLikely Benign0.140Likely Benign-0.26Neutral0.951Possibly Damaging0.803Possibly Damaging2.66Benign0.08Tolerated0.13120.458511-2.727.03
c.3365G>A
G1122D
2D
AIThe SynGAP1 missense variant G1122D is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Optimized. Only ESM1b predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also favors benign (2 benign vs. 1 pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that G1122D is most likely benign, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.896620Disordered0.814918Binding0.3570.9320.875-9.991Likely Pathogenic0.430AmbiguousLikely Benign0.332Likely Benign-0.49Neutral0.411Benign0.091Benign4.49Benign0.10Tolerated0.17460.20351-1-3.158.04
c.119A>T
D40V
2D
AIThe SynGAP1 missense variant D40V is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign effect. No Foldetta stability prediction is available for this variant. Overall, the majority of computational evidence points to a benign impact, and this conclusion does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.384043Structured0.432002Uncertain0.3190.7690.375-3.350Likely Benign0.431AmbiguousLikely Benign0.222Likely Benign-1.16Neutral0.028Benign0.088Benign4.00Benign0.00Affected0.16790.8357-2-37.7-15.96
c.1711T>A
S571T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S571T is not reported in ClinVar (ClinVar ID: None) and has no entry in gnomAD (gnomAD ID: None). Prediction tools that indicate a benign effect include FoldX, Rosetta, Foldetta, premPS, SIFT, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SGM‑Consensus, REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) as benign. Overall, the majority of tools (seven) predict pathogenicity, while six predict benignity, and the high‑accuracy subset is split. Thus, the variant is most likely pathogenic based on the prevailing predictions, and this assessment does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.069024Structured0.045569Uncertain0.9280.2700.000-8.243Likely Pathogenic0.431AmbiguousLikely Benign0.37Likely Benign0.1-0.21Likely Benign0.08Likely Benign0.25Likely Benign0.564Likely Pathogenic-2.76Deleterious0.933Possibly Damaging0.933Probably Damaging-1.25Pathogenic0.10Tolerated0.13600.4014110.114.03
c.2432C>A
P811Q
2D
AIThe SynGAP1 missense variant P811Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists). Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.411940Structured0.847064Binding0.3820.9100.250-5.145Likely Benign0.431AmbiguousLikely Benign0.138Likely Benign-2.38Neutral0.982Probably Damaging0.875Possibly Damaging2.78Benign0.01Affected0.15230.53380-1-1.931.01
c.1229G>T
S410I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S410I is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, Rosetta, premPS, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Predictions that are uncertain or inconclusive are FoldX, Foldetta, and AlphaMissense‑Default. High‑accuracy methods give a mixed picture: AlphaMissense‑Optimized classifies the variant as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) leans pathogenic, and Foldetta remains uncertain. Overall, the majority of tools suggest a benign impact, but the high‑accuracy consensus indicates potential pathogenicity, leaving the variant’s effect ambiguous. Based on the aggregate predictions, the variant is most likely benign, and this assessment does not contradict the ClinVar status, which currently has no entry for it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.098513Structured0.349627Uncertain0.9080.2060.000-9.383Likely Pathogenic0.432AmbiguousLikely Benign-1.08Ambiguous0.2-0.36Likely Benign-0.72Ambiguous-0.41Likely Benign0.114Likely Benign-3.21Deleterious0.993Probably Damaging0.589Possibly Damaging4.15Benign0.21Tolerated0.09650.6579-1-25.326.08
c.1730C>T
A577V
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant A577V is catalogued in gnomAD (ID 6‑33440782‑C‑T) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, Rosetta, premPS, PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores benign; the SGM consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields benign; and Foldetta, which integrates FoldX‑MD and Rosetta outputs, also reports benign. No prediction or stability result is missing or inconclusive in these key analyses. Consequently, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.113710Structured0.019074Uncertain0.9130.2390.0006-33440782-C-T21.24e-6-4.265Likely Benign0.432AmbiguousLikely Benign0.69Ambiguous0.10.00Likely Benign0.35Likely Benign0.16Likely Benign0.417Likely Benign-2.11Neutral0.997Probably Damaging0.976Probably Damaging-1.32Pathogenic0.26Tolerated3.37340.12780.4790002.428.05
c.2927T>C
F976S
2D
AIThe SynGAP1 missense variant F976S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.975061Binding0.3110.8940.625-2.393Likely Benign0.432AmbiguousLikely Benign0.217Likely Benign-0.73Neutral0.292Benign0.102Benign4.16Benign0.49Tolerated0.44320.1134-3-2-3.6-60.10
c.3377G>A
G1126D
2D
AISynGAP1 missense variant G1126D is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Functional prediction tools show a split opinion: benign predictions come from REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized, whereas pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. The AlphaMissense‑Default result is uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields benign. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign effect, which is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.894241Disordered0.837209Binding0.3450.9180.875Uncertain 1-8.888Likely Pathogenic0.432AmbiguousLikely Benign0.376Likely Benign-0.65Neutral0.906Possibly Damaging0.473Possibly Damaging4.82Benign0.02Affected3.7750.17250.22241-1-3.158.04
c.524A>C
Q175P
2D
AIThe SynGAP1 missense variant Q175P is reported in gnomAD (ID 6‑33435166‑A‑C) but has no ClinVar entry. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all score the substitution as benign. The consensus from the SGM framework, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also classifies the variant as likely benign. High‑accuracy predictors corroborate this assessment: AlphaMissense‑Optimized predicts a benign outcome, and the SGM‑Consensus (majority vote) confirms a likely benign status. No high‑accuracy folding‑stability analysis (Foldetta) is available for this residue, so stability effects remain unassessed. Overall, the collective evidence points to a benign impact for Q175P, and this conclusion is consistent with the absence of a pathogenic ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.653063Disordered0.474689Uncertain0.3670.6180.3756-33435166-A-C16.20e-7-6.995Likely Benign0.432AmbiguousLikely Benign0.211Likely Benign1.55Neutral0.396Benign0.188Benign4.20Benign1.00Tolerated3.6150.20750.4584-101.9-31.01
c.1760G>A
R587K
2D
3DClick to see structure in 3D Viewer
AISynGAP1 R587K is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions from SIFT and AlphaMissense‑Optimized, and pathogenic predictions from REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. The remaining tools (FoldX, Rosetta, Foldetta, premPS, AlphaMissense‑Default) give uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM‑Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—indicates likely pathogenic. Foldetta, which integrates FoldX‑MD and Rosetta outputs, remains uncertain. Overall, the majority of evidence points toward a pathogenic effect, which is consistent with the SGM‑Consensus prediction but contradicts the benign calls from SIFT and AlphaMissense‑Optimized. Thus, the variant is most likely pathogenic, and this conclusion aligns with the lack of ClinVar annotation rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.054297Structured0.077330Uncertain0.8620.2160.000-10.220Likely Pathogenic0.433AmbiguousLikely Benign0.63Ambiguous0.11.14Ambiguous0.89Ambiguous0.88Ambiguous0.539Likely Pathogenic-2.55Deleterious0.967Probably Damaging0.955Probably Damaging-1.16Pathogenic0.07Tolerated0.53130.3897Weaken320.6-28.01
c.1900G>T
A634S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 A634S variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect are FATHMM and AlphaMissense‑Optimized; those that agree on a pathogenic effect are REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. The remaining tools (FoldX, Rosetta, Foldetta, premPS, AlphaMissense‑Default) are inconclusive. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the majority of evidence points to a pathogenic impact, and this conclusion does not contradict the ClinVar status, which simply lacks an entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.085092Structured0.052058Uncertain0.9320.2420.000-9.706Likely Pathogenic0.434AmbiguousLikely Benign0.91Ambiguous0.11.28Ambiguous1.10Ambiguous0.77Ambiguous0.506Likely Pathogenic-2.99Deleterious0.953Possibly Damaging0.985Probably Damaging2.67Benign0.05Affected0.26070.423111-2.616.00
c.2195G>C
R732T
2D
AISynGAP1 missense variant R732T is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Functional prediction tools cluster into two groups: benign (REVEL, PROVEAN, SIFT, FATHMM, AlphaMissense‑Optimized) and pathogenic (polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b). AlphaMissense‑Default remains uncertain. The high‑accuracy AlphaMissense‑Optimized predicts a benign effect, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also favors a benign outcome. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from both general and high‑accuracy predictors points to a benign impact, which does not contradict the current ClinVar designation of uncertain significance.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.846163Disordered0.412403Uncertain0.4270.6730.750Uncertain 1-8.545Likely Pathogenic0.434AmbiguousLikely Benign0.075Likely Benign-1.96Neutral0.999Probably Damaging0.892Possibly Damaging2.59Benign0.12Tolerated3.5970.19150.3153-1-13.8-55.08
c.2935T>G
F979V
2D
AIThe SynGAP1 missense variant F979V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for F979V, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.977500Binding0.2740.8890.625-3.325Likely Benign0.434AmbiguousLikely Benign0.199Likely Benign-1.03Neutral0.925Possibly Damaging0.629Possibly Damaging4.21Benign0.04Affected0.22600.3176-1-11.4-48.04
c.512C>T
A171V
2D
AIThe SynGAP1 missense variant A171V is catalogued in gnomAD (ID 6‑33435154‑C‑T) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as “Likely Benign.” High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the preponderance of evidence points to a benign impact for A171V, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.562014Disordered0.492272Uncertain0.3580.6520.3756-33435154-C-T16.20e-7-6.437Likely Benign0.434AmbiguousLikely Benign0.052Likely Benign-1.65Neutral0.118Benign0.026Benign4.15Benign0.03Affected3.7440.07660.4897002.428.05
c.59C>G
P20R
2D
AIThe SynGAP1 missense variant P20R is listed in ClinVar (ID 566521.0) with an “Uncertain” status and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the current ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.529623Disordered0.442804Uncertain0.4480.8990.500Uncertain 1-3.548Likely Benign0.434AmbiguousLikely Benign0.146Likely Benign-0.15Neutral0.972Probably Damaging0.804Possibly Damaging4.33Benign0.00Affected4.3210.15090.32720-2-2.959.07
c.2362T>C
S788P
2D
AIThe SynGAP1 missense variant S788P is catalogued in gnomAD (ID 6‑33442914‑T‑C) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, ESM1b, and AlphaMissense‑Optimized, whereas pathogenic predictions are reported by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. The AlphaMissense‑Default score is uncertain. A consensus derived from the SGM framework (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a pathogenic verdict. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus as pathogenic, and Foldetta (combining FoldX‑MD and Rosetta) is unavailable for this residue. Taken together, the preponderance of evidence from standard predictors and the SGM consensus points to a likely pathogenic effect, which does not contradict any existing ClinVar annotation because none is present.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.956248Disordered0.573557Binding0.3490.8950.7506-33442914-T-C-1.857Likely Benign0.435AmbiguousLikely Benign0.236Likely Benign-3.91Deleterious0.997Probably Damaging0.995Probably Damaging1.51Pathogenic0.01Affected3.6460.23380.5537-11-0.810.04
c.2966C>T
S989F
2D
AIThe SynGAP1 missense variant S989F is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also predicts benign, and Foldetta results are unavailable. Overall, the majority of reliable predictors and the consensus high‑accuracy tools indicate a benign impact. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.795062Disordered0.908835Binding0.2960.9110.750-4.115Likely Benign0.435AmbiguousLikely Benign0.109Likely Benign-3.35Deleterious0.986Probably Damaging0.876Possibly Damaging2.60Benign0.00Affected0.05980.5103-3-23.660.10
c.3107A>T
Q1036L
2D
AIThe SynGAP1 missense variant Q1036L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors a benign outcome, with two benign votes versus one pathogenic and one uncertain. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.948786Disordered0.987955Binding0.2750.7650.625-4.389Likely Benign0.435AmbiguousLikely Benign0.092Likely Benign-2.92Deleterious0.152Benign0.045Benign2.52Benign0.01Affected0.10690.5996-2-27.3-14.97
c.3142G>A
G1048R
2D
AIThe SynGAP1 missense variant G1048R is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Functional prediction tools show a split: pathogenic calls come from REVEL, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar, whereas benign calls are made by PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus, derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a benign majority, and AlphaMissense‑Optimized itself predicts benign. The SGM‑Consensus, which aggregates these four predictors, reports a likely benign classification. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the absence of a ClinVar assertion; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.923876Binding0.3460.9160.750-4.305Likely Benign0.435AmbiguousLikely Benign0.503Likely Pathogenic-0.54Neutral0.919Possibly Damaging0.728Possibly Damaging2.54Benign0.10Tolerated3.7750.09560.4332-2-3-4.199.14
c.3142G>C
G1048R
2D
AIThe SynGAP1 missense variant G1048R is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Prediction tools that agree on a benign effect include PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are REVEL, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. The high‑accuracy AlphaMissense‑Optimized score is benign, and the SGM‑Consensus also indicates a likely benign outcome; the Foldetta protein‑folding stability assessment is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.977651Disordered0.923876Binding0.3460.9160.750Uncertain 1-4.305Likely Benign0.435AmbiguousLikely Benign0.503Likely Pathogenic-0.54Neutral0.919Possibly Damaging0.728Possibly Damaging2.54Benign0.10Tolerated3.7750.09560.4332-2-3-4.199.14
c.1382C>T
A461V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A461V is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, SIFT, FATHMM, AlphaMissense‑Optimized, and polyPhen2_HumVar. Tools that predict a pathogenic effect are PROVEAN, polyPhen2_HumDiv, and ESM1b. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic. Because the majority of standard predictors (nine benign vs. three pathogenic) favor a benign outcome, the variant is most likely benign, and this assessment does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.179055Structured0.292531Uncertain0.9360.1510.125-9.968Likely Pathogenic0.436AmbiguousLikely Benign-0.08Likely Benign0.30.34Likely Benign0.13Likely Benign0.02Likely Benign0.141Likely Benign-3.05Deleterious0.983Probably Damaging0.273Benign3.43Benign0.66Tolerated0.08190.5078002.428.05
c.2113A>C
K705Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 K705Q missense variant (ClinVar ID 3699560.0) is listed as “Uncertain” in ClinVar and is present in gnomAD (variant ID 6‑33441372‑A‑C). Prediction tools that uniformly indicate a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus—derived from a majority vote of AlphaMissense‑Default (uncertain), ESM1b (benign), FATHMM (benign), and PROVEAN (benign)—also yields a benign classification; Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, predicts benign. Overall, the preponderance of evidence supports a benign impact for K705Q, and this conclusion does not contradict the ClinVar “Uncertain” status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.134866Structured0.379324Uncertain0.9220.3640.000Uncertain 16-33441372-A-C16.20e-7-5.787Likely Benign0.436AmbiguousLikely Benign-0.10Likely Benign0.00.33Likely Benign0.12Likely Benign-0.02Likely Benign0.142Likely Benign-0.24Neutral0.997Probably Damaging0.969Probably Damaging3.42Benign0.78Tolerated3.47100.30630.1014110.4-0.04
c.2122C>T
L708F
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant L708F is not reported in ClinVar and is present in gnomAD (ID 6‑33441587‑C‑T). Functional prediction tools that reach consensus classify the change as benign: REVEL, premPS, PROVEAN, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Optimized. Pathogenic predictions are limited to polyPhen‑2 HumDiv and ESM1b. The remaining tools (FoldX, Rosetta, Foldetta, AlphaMissense‑Default) return uncertain or no result. High‑accuracy assessments give AlphaMissense‑Optimized a benign score, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also predicts benign, and Foldetta indicates no significant destabilization (uncertain). Overall, the preponderance of evidence supports a benign effect for L708F, and this conclusion is consistent with the absence of a ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.250310Structured0.365875Uncertain0.9310.3780.0006-33441587-C-T21.24e-6-9.154Likely Pathogenic0.436AmbiguousLikely Benign1.48Ambiguous0.30.93Ambiguous1.21Ambiguous0.37Likely Benign0.110Likely Benign-2.46Neutral0.931Possibly Damaging0.326Benign3.29Benign0.07Tolerated3.5090.04970.236602-1.034.02
c.2173C>A
L725M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L725M is not reported in ClinVar (ClinVar status: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, FoldX, PROVEAN, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. Uncertain or inconclusive predictions come from Foldetta, premPS, AlphaMissense‑Default, and Rosetta. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) leans pathogenic (2 pathogenic vs. 1 benign). Foldetta remains uncertain and is not used as evidence. Overall, the majority of tools, including the high‑accuracy consensus, predict a pathogenic impact. This conclusion does not contradict ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.557691Disordered0.455613Uncertain0.9110.4910.625-9.531Likely Pathogenic0.436AmbiguousLikely Benign0.42Likely Benign0.11.05Ambiguous0.74Ambiguous0.80Ambiguous0.172Likely Benign-1.81Neutral1.000Probably Damaging1.000Probably Damaging1.32Pathogenic0.04Affected0.08540.415642-1.918.03
c.1514A>T
Y505F
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Y505F is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, FoldX, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Predictions that are uncertain or inconclusive are Rosetta, Foldetta, premPS, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the majority of tools (five benign versus four pathogenic) lean toward a benign interpretation, and this is consistent with the lack of ClinVar evidence; thus the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.047319Structured0.292227Uncertain0.9090.1880.000-8.855Likely Pathogenic0.437AmbiguousLikely Benign0.40Likely Benign0.00.76Ambiguous0.58Ambiguous0.69Ambiguous0.434Likely Benign-3.98Deleterious1.000Probably Damaging0.996Probably Damaging2.93Benign0.07Tolerated0.24090.2598734.1-16.00
c.190A>C
I64L
2D
AIThe SynGAP1 missense variant I64L is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus indicates Likely Benign, and Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for I64L, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.422041Structured0.475481Uncertain0.4780.7470.125-2.498Likely Benign0.437AmbiguousLikely Benign0.087Likely Benign-0.27Neutral0.010Benign0.001Benign4.13Benign0.00Affected0.06280.303022-0.70.00
c.190A>T
I64L
2D
AIThe SynGAP1 missense variant I64L is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus indicates Likely Benign, and Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.422041Structured0.475481Uncertain0.4780.7470.125-2.498Likely Benign0.437AmbiguousLikely Benign0.087Likely Benign-0.27Neutral0.010Benign0.001Benign4.13Benign0.00Affected0.06280.303022-0.70.00
c.3725A>C
E1242A
2D
AIThe SynGAP1 missense variant E1242A is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evaluated tools (five pathogenic vs. three benign) predict a pathogenic impact. This prediction does not contradict ClinVar status, as the variant is not yet catalogued there. Thus, based on current computational evidence, the variant is most likely pathogenic.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.557691Disordered0.456349Uncertain0.8700.5490.500-5.654Likely Benign0.437AmbiguousLikely Benign0.187Likely Benign-4.66Deleterious0.939Possibly Damaging0.735Possibly Damaging2.21Pathogenic0.00Affected0.27380.41690-15.3-58.04
c.686A>G
K229R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 K229R missense variant is catalogued in gnomAD (ID 6‑33435537‑A‑G) but has no entry in ClinVar. Functional prediction tools largely agree on a benign effect: FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict benign. In contrast, REVEL, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar predict pathogenic. AlphaMissense‑Default is uncertain and is treated as unavailable. The high‑accuracy consensus methods reinforce the benign assessment: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) is benign. Overall, the majority of evidence supports a benign classification, and this is consistent with the absence of a ClinVar pathogenic report.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.179055Structured0.310912Uncertain0.8430.3060.0006-33435537-A-G16.20e-7-5.651Likely Benign0.437AmbiguousLikely Benign0.09Likely Benign0.00.02Likely Benign0.06Likely Benign0.40Likely Benign0.628Likely Pathogenic-2.00Neutral0.993Probably Damaging0.971Probably Damaging5.84Benign0.19Tolerated3.43120.49210.097223-0.628.01
c.1141G>T
G381W
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G381W is not reported in ClinVar (ClinVar ID None) but is present in gnomAD (ID 6‑33438046‑G‑T). Prediction tools that agree on a benign effect include premPS, PROVEAN, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are REVEL, FoldX, Rosetta, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments give AlphaMissense‑Optimized a benign call, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) a pathogenic call, and Foldetta (combining FoldX‑MD and Rosetta outputs) a pathogenic call. No prediction or folding result is missing or inconclusive. Overall, the majority of tools and the high‑accuracy methods indicate a pathogenic impact. Thus, the variant is most likely pathogenic, and this assessment does not contradict the ClinVar status, which has no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.724957Disordered0.431692Uncertain0.3010.9510.7506-33438046-G-T16.24e-7-10.173Likely Pathogenic0.438AmbiguousLikely Benign8.81Destabilizing2.03.17Destabilizing5.99Destabilizing0.02Likely Benign0.576Likely Pathogenic-1.04Neutral0.996Probably Damaging0.920Probably Damaging1.31Pathogenic0.01Affected4.3290.09930.4000-2-7-0.5129.16
c.3313C>G
R1105G
2D
AIThe SynGAP1 missense variant R1105G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Consensus from standard in silico predictors shows a split: benign calls come from REVEL, polyPhen‑2 HumVar, SIFT, ESM1b, and AlphaMissense‑Optimized, while pathogenic calls come from PROVEAN, polyPhen‑2 HumDiv, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessment gives a benign prediction from AlphaMissense‑Optimized, a pathogenic consensus from the SGM method (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), and no result from Foldetta, so its stability impact is unavailable. Overall, the majority of tools lean toward a benign effect, but the high‑accuracy consensus is conflicted. Thus, the variant is most likely benign based on the bulk of predictions, and this assessment does not contradict any ClinVar status because the variant is not yet catalogued in ClinVar.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.901269Disordered0.954396Binding0.3300.8630.875-4.900Likely Benign0.438AmbiguousLikely Benign0.146Likely Benign-3.48Deleterious0.677Possibly Damaging0.168Benign2.45Pathogenic0.09Tolerated0.32930.4269-3-24.1-99.14
c.473A>G
Q158R
2D
AIThe SynGAP1 missense variant Q158R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and AlphaMissense‑Optimized also reports a benign prediction. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. The predictions do not contradict ClinVar status, as ClinVar contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.527565Binding0.2860.7500.375-6.873Likely Benign0.438AmbiguousLikely Benign0.090Likely Benign-0.85Neutral0.276Benign0.121Benign4.14Benign0.11Tolerated0.15270.149811-1.028.06
c.1147G>T
G383W
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant G383W is listed in ClinVar with an uncertain significance and is present in gnomAD (ID 6‑33438052‑G‑T). Functional prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are FoldX, Rosetta, Foldetta, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as benign, and Foldetta as pathogenic. Because the majority of conventional predictors favor pathogenicity while the high‑accuracy subset is split, the overall evidence leans toward a pathogenic interpretation. This conclusion does not conflict with the ClinVar uncertain status, which reflects the current lack of definitive clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.728858Disordered0.429104Uncertain0.2960.9490.750Uncertain 16-33438052-G-T16.22e-7-10.161Likely Pathogenic0.439AmbiguousLikely Benign5.81Destabilizing3.64.44Destabilizing5.13Destabilizing0.08Likely Benign0.469Likely Benign-1.01Neutral0.959Probably Damaging0.704Possibly Damaging4.09Benign0.00Affected4.3270.09720.3785-2-7-0.5129.16
c.1280A>G
H427R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant H427R is not reported in ClinVar (ClinVar ID None) but is present in gnomAD (ID 6‑33438185‑A‑G). Functional prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and SIFT, while premPS and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also resolves to benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts a benign stability change. No predictions or folding results are missing or inconclusive. Overall, the majority of evidence indicates the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.081712Structured0.394261Uncertain0.9620.2870.0006-33438185-A-G-3.259Likely Benign0.439AmbiguousLikely Benign-0.04Likely Benign0.10.48Likely Benign0.22Likely Benign0.72Ambiguous0.168Likely Benign-2.61Deleterious0.174Benign0.018Benign3.51Benign0.03Affected3.38250.21080.212102-1.319.05
c.212A>G
D71G
2D
AIThe SynGAP1 missense variant D71G is not reported in ClinVar (ClinVar ID None) but is present in gnomAD (ID 6‑33425820‑A‑G). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.575842Disordered0.456046Uncertain0.3500.7990.3756-33425820-A-G16.20e-7-3.136Likely Benign0.439AmbiguousLikely Benign0.111Likely Benign-1.82Neutral0.171Benign0.021Benign4.03Benign0.00Affected4.3210.38020.5704-113.1-58.04
c.3820C>T
R1274C
2D
AIThe SynGAP1 missense variant R1274C is listed in ClinVar with an “Uncertain” significance and is present in gnomAD (ID 6‑33447868‑C‑T). Prediction tools that agree on benign impact include REVEL, ESM1b, and AlphaMissense‑Optimized, while those that predict pathogenicity are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). AlphaMissense‑Default remains uncertain, and Foldetta results are unavailable. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus as pathogenic, and no Foldetta data to weigh in. Overall, the majority of evaluated tools (seven pathogenic vs. three benign) suggest a pathogenic effect. This consensus does not contradict the ClinVar “Uncertain” status, which remains inconclusive.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.613573Disordered0.779985Binding0.7460.6880.625Uncertain 16-33447868-C-T-6.467Likely Benign0.439AmbiguousLikely Benign0.170Likely Benign-5.22Deleterious1.000Probably Damaging0.996Probably Damaging2.46Pathogenic0.00Affected3.7750.32320.1517-4-37.0-53.05
c.5G>T
S2I
2D
AIThe SynGAP1 missense variant S2I is catalogued in gnomAD (6‑33420269‑G‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all report benign or likely benign. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments confirm the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus, derived from the majority of the high‑confidence predictors, is benign. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that S2I is most likely benign, and this assessment does not contradict any ClinVar status, as none is reported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.543646Binding0.3820.9220.7506-33420269-G-T-4.947Likely Benign0.439AmbiguousLikely Benign0.031Likely Benign-0.59Neutral0.212Benign0.020Benign4.04Benign0.00Affected4.3210.10210.5980-2-15.326.08
c.3683A>T
E1228V
2D
AIThe SynGAP1 missense variant E1228V is not reported in ClinVar and is absent from gnomAD. Prediction tools cluster into two groups: benign predictions come from REVEL and AlphaMissense‑Optimized, while pathogenic predictions arise from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and the SGM‑Consensus score, which is a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN. AlphaMissense‑Default remains uncertain. High‑accuracy assessments further separate the evidence: AlphaMissense‑Optimized indicates a benign effect, whereas the SGM‑Consensus, derived from a consensus of four high‑confidence predictors, flags the variant as pathogenic. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this change. Overall, the preponderance of pathogenic predictions, including the SGM‑Consensus, outweighs the benign calls. Therefore, the variant is most likely pathogenic, and this assessment does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicCoiled-coil0.517562Disordered0.447051Uncertain0.8920.5460.500-8.077Likely Pathogenic0.440AmbiguousLikely Benign0.293Likely Benign-4.55Deleterious0.980Probably Damaging0.833Possibly Damaging2.43Pathogenic0.00Affected0.04700.4252-2-27.7-29.98
c.430A>G
T144A
2D
AIThe SynGAP1 missense variant T144A is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also reports a benign prediction. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.666105Disordered0.524000Binding0.3350.8380.625-4.007Likely Benign0.440AmbiguousLikely Benign0.065Likely Benign-2.24Neutral0.000Benign0.001Benign3.95Benign0.00Affected0.47770.4131102.5-30.03
c.946A>C
N316H
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant N316H is not reported in ClinVar (status: None) and is absent from gnomAD. Prediction tools that classify the variant as benign include REVEL, Rosetta, Foldetta, and AlphaMissense‑Optimized. Tools that predict pathogenicity are SGM‑Consensus, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. High‑accuracy methods give the following results: AlphaMissense‑Optimized predicts a benign effect; the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default (uncertain), ESM1b (pathogenic), FATHMM (pathogenic), and PROVEAN (pathogenic), indicates a likely pathogenic outcome; Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, predicts a benign impact. FoldX and premPS are inconclusive. Overall, the balance of evidence from the majority of prediction tools points to a pathogenic effect, and this assessment does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicC20.118441Structured0.385187Uncertain0.8170.2460.125-8.141Likely Pathogenic0.440AmbiguousLikely Benign0.72Ambiguous0.40.07Likely Benign0.40Likely Benign0.62Ambiguous0.306Likely Benign-3.56Deleterious1.000Probably Damaging0.999Probably Damaging1.76Pathogenic0.02Affected0.15550.7702210.323.04
c.1301T>C
V434A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 V434A missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect comprise Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), and ESM1b; FoldX and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as pathogenic. Overall, the majority of evidence points to a pathogenic impact. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.158265Structured0.342846Uncertain0.9540.3060.000-8.531Likely Pathogenic0.441AmbiguousLikely Benign1.72Ambiguous0.02.51Destabilizing2.12Destabilizing1.00Destabilizing0.238Likely Benign-2.51Deleterious1.000Probably Damaging0.999Probably Damaging3.58Benign0.75Tolerated0.23380.229200-2.4-28.05
c.1649C>T
A550V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 A550V variant has no ClinVar entry and is catalogued in gnomAD (ID 6‑33438892‑C‑T). Prediction tools that agree on a benign effect include Foldetta, premPS, SIFT, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Uncertain results come from FoldX and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as pathogenic, and Foldetta as benign. Overall, the majority of tools (seven versus four) favor a pathogenic interpretation, and this does not contradict any ClinVar classification because none is available. Thus, based on the current predictions, the variant is most likely pathogenic.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.018106Structured0.007241Uncertain0.9540.2650.0006-33438892-C-T16.20e-7-10.461Likely Pathogenic0.441AmbiguousLikely Benign0.77Ambiguous0.2-0.05Likely Benign0.36Likely Benign0.48Likely Benign0.540Likely Pathogenic-2.93Deleterious0.984Probably Damaging0.494Possibly Damaging-1.05Pathogenic0.39Tolerated3.37330.08740.4370002.428.05
c.2600G>T
G867V
2D
AIThe SynGAP1 missense variant G867V is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Two tools—ESM1b and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because it yields a 2‑to‑2 split between benign and uncertain calls. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the balance of evidence (five benign predictions versus two pathogenic predictions, with no decisive high‑accuracy support for pathogenicity) indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.517562Disordered0.657954Binding0.2850.8010.250-7.049In-Between0.441AmbiguousLikely Benign0.111Likely Benign-2.23Neutral0.999Probably Damaging0.958Probably Damaging2.70Benign0.10Tolerated0.11250.4613-1-34.642.08
c.3518T>C
I1173T
2D
AIThe SynGAP1 missense variant I1173T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign effect for I1173T, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.501700Disordered0.653145Binding0.5210.7560.375-3.162Likely Benign0.441AmbiguousLikely Benign0.405Likely Benign-1.18Neutral0.451Benign0.265Benign5.46Benign0.05Affected0.10160.08210-1-5.2-12.05
c.1973G>A
G658D
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant G658D is listed in ClinVar with an uncertain significance and is present in gnomAD (ID 6-33441232‑G‑A). Functional prediction tools that agree on a benign effect include REVEL, FoldX, premPS, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Optimized. Only PROVEAN predicts a pathogenic outcome, while Rosetta, Foldetta, ESM1b, and AlphaMissense‑Default are inconclusive. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive, and Foldetta, which integrates FoldX‑MD and Rosetta, is also inconclusive. Overall, the preponderance of evidence points to a benign effect, and this does not contradict the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.029376Structured0.180299Uncertain0.9420.2510.000Uncertain 16-33441232-G-A31.86e-6-7.786In-Between0.442AmbiguousLikely Benign-0.40Likely Benign0.1-0.59Ambiguous-0.50Ambiguous0.46Likely Benign0.144Likely Benign-2.64Deleterious0.008Benign0.005Benign3.53Benign0.38Tolerated3.39240.21060.23331-1-3.158.04219.8-84.30.00.00.20.1XPotentially PathogenicGly658, located on the outer surface of an α helix (res. Ser641-Glu666), weakens the helix integrity at that spot, which is necessary for the kink in the middle of the long helix. In the variant simulations, the carboxylic acid side chain of Asp658 is on the surface of the α helix and is not involved in any interactions. However, aspartate is not as effective a breaker of the secondary structure element as glycine, which may lead to misfolding.
c.202C>A
L68M
2D
AIThe SynGAP1 missense variant L68M is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in‑silico predictors shows a split: benign calls come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic calls arise from polyPhen‑2 (HumDiv and HumVar) and SIFT. The AlphaMissense‑Default tool remains uncertain. High‑accuracy assessments reinforce the benign trend: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports Likely Benign, and no Foldetta stability data are available. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the lack of ClinVar annotation and gnomAD presence, so there is no contradiction with existing clinical databases.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.470567Uncertain0.4050.7680.250-5.580Likely Benign0.442AmbiguousLikely Benign0.094Likely Benign-0.13Neutral0.824Possibly Damaging0.665Possibly Damaging4.09Benign0.00Affected0.05650.276242-1.918.03
c.2315T>C
F772S
2D
AIThe SynGAP1 missense variant F772S is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority of other predictors (polyPhen‑2 HumDiv and HumVar) suggest pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign and the SGM‑Consensus likewise indicates Likely Benign; Foldetta data are not available. Overall, the preponderance of evidence points to a benign effect for F772S, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.450668Structured0.922662Binding0.3290.8840.250-2.722Likely Benign0.442AmbiguousLikely Benign0.138Likely Benign-0.26Neutral0.845Possibly Damaging0.899Possibly Damaging4.21Benign0.56Tolerated0.41340.0558-3-2-3.6-60.10
c.3386T>G
L1129R
2D
AIThe SynGAP1 missense variant L1129R is not reported in ClinVar and has no entry in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.903857Disordered0.876543Binding0.3390.9090.875-2.613Likely Benign0.442AmbiguousLikely Benign0.376Likely Benign-1.68Neutral0.005Benign0.007Benign5.48Benign0.00Affected0.13340.1636-3-2-8.343.03
c.740A>G
Q247R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q247R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Uncertain predictions come from premPS and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as benign. No prediction or folding stability result is missing or inconclusive. Based on the overall consensus of the majority of tools and the high‑accuracy methods, the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.490133Structured0.283012Uncertain0.8220.3390.250-4.022Likely Benign0.442AmbiguousLikely Benign-0.38Likely Benign0.00.21Likely Benign-0.09Likely Benign-0.91Ambiguous0.471Likely Benign1.22Neutral0.948Possibly Damaging0.533Possibly Damaging5.91Benign1.00Tolerated0.11960.132411-1.028.06
c.2117A>C
E706A
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant E706A has no ClinVar entry and is not reported in gnomAD. Prediction tools largely agree on a benign effect: REVEL, Rosetta, premPS, PROVEAN, polyPhen2_HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict benign. Only polyPhen2_HumDiv suggests pathogenicity, while FoldX, Foldetta, and AlphaMissense‑Default are uncertain. High‑accuracy methods reinforce the benign consensus: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is benign; Foldetta remains uncertain. Overall, the majority of evidence points to a benign impact, and this is consistent with the absence of ClinVar classification or gnomAD observation. Thus, the variant is most likely benign, and this is consistent with the lack of ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.200174Structured0.377033Uncertain0.9290.3630.000-4.604Likely Benign0.443AmbiguousLikely Benign0.80Ambiguous0.00.48Likely Benign0.64Ambiguous-0.12Likely Benign0.117Likely Benign-0.81Neutral0.613Possibly Damaging0.180Benign4.20Benign0.65Tolerated0.34130.40890-15.3-58.04
c.3887A>T
E1296V
2D
AIThe SynGAP1 missense variant E1296V is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta) has no available result for this variant. High‑accuracy predictions therefore indicate a benign outcome: AlphaMissense‑Optimized is benign, the SGM Consensus is benign, and no Foldetta data are available. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.837511Disordered0.894444Binding0.5300.8090.625-3.384Likely Benign0.443AmbiguousLikely Benign0.229Likely Benign-4.24Deleterious0.992Probably Damaging0.902Possibly Damaging2.62Benign0.01Affected0.06780.6040-2-27.7-29.98
c.893C>A
P298H
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 P298H missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. Remaining tools (AlphaMissense‑Default, FoldX, Rosetta, Foldetta, premPS) are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic, and Foldetta is uncertain. Overall, the majority of predictions (five pathogenic vs. three benign) and the SGM Consensus support a pathogenic interpretation. Therefore, the variant is most likely pathogenic, and this conclusion does not contradict the ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.328603Structured0.268765Uncertain0.8600.2830.500-9.777Likely Pathogenic0.443AmbiguousLikely Benign1.57Ambiguous0.21.49Ambiguous1.53Ambiguous0.83Ambiguous0.313Likely Benign-2.37Neutral0.999Probably Damaging0.964Probably Damaging1.92Pathogenic0.04Affected0.17690.49430-2-1.640.02
c.1103C>T
P368L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant P368L is not reported in ClinVar (ClinVar ID None) but is present in gnomAD (ID 6‑33438008‑C‑T). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. Predictions that are uncertain or inconclusive are FoldX, Rosetta, premPS, AlphaMissense‑Default, and Foldetta. High‑accuracy assessments give AlphaMissense‑Optimized a benign score, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is pathogenic. Foldetta, which integrates FoldX‑MD and Rosetta outputs, is uncertain. Based on the overall distribution of predictions, the variant is most likely pathogenic. This assessment does not contradict ClinVar status, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.363090Structured0.439989Uncertain0.5800.6770.2506-33438008-C-T16.33e-7-6.520Likely Benign0.444AmbiguousLikely Benign1.52Ambiguous0.71.15Ambiguous1.34Ambiguous0.52Ambiguous0.248Likely Benign-6.61Deleterious0.991Probably Damaging0.831Possibly Damaging1.77Pathogenic0.00Affected3.42190.23360.7125-3-35.416.04
c.2414T>C
L805P
2D
AIThe SynGAP1 missense variant L805P is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Functional prediction tools show a split: benign calls come from REVEL, ESM1b, and AlphaMissense‑Optimized, while pathogenic calls are made by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments give a benign result from AlphaMissense‑Optimized, a pathogenic outcome from the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), and no Foldetta data are available. Overall, the majority of predictions lean toward pathogenicity, and this conclusion does not conflict with the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.775545Disordered0.827669Binding0.3410.9030.625Uncertain 1-4.661Likely Benign0.444AmbiguousLikely Benign0.272Likely Benign-3.40Deleterious0.975Probably Damaging0.767Possibly Damaging2.36Pathogenic0.00Affected3.7750.31280.1650-3-3-5.4-16.04
c.722A>G
K241R
2D
AIThe SynGAP1 missense variant K241R is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include FoldX, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are REVEL, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, indicates a likely benign outcome. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus (majority vote) is likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts benign. No prediction or folding stability result is missing or inconclusive. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.196879Structured0.349250Uncertain0.7970.3470.000-4.615Likely Benign0.444AmbiguousLikely Benign-0.23Likely Benign0.5-0.03Likely Benign-0.13Likely Benign0.43Likely Benign0.602Likely Pathogenic-2.12Neutral0.982Probably Damaging0.679Possibly Damaging5.89Benign0.14Tolerated0.45710.124232-0.628.01
c.983A>T
Y328F
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Y328F is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) as benign. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.411940Structured0.392519Uncertain0.9160.4970.000-6.770Likely Benign0.444AmbiguousLikely Benign0.34Likely Benign0.10.43Likely Benign0.39Likely Benign0.37Likely Benign0.330Likely Benign-3.21Deleterious0.999Probably Damaging0.992Probably Damaging1.67Pathogenic0.16Tolerated0.24090.3643734.1-16.00
c.2018T>A
L673Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L673Q is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FATHMM, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect include Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. FoldX and Foldetta, as well as AlphaMissense‑Default, are inconclusive and are treated as unavailable evidence. High‑accuracy assessments show AlphaMissense‑Optimized predicting benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic. Foldetta remains uncertain. Overall, the majority of available predictions (seven pathogenic vs. three benign) indicate that the variant is most likely pathogenic, and this conclusion does not contradict any ClinVar annotation because no ClinVar claim exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.060549Structured0.104692Uncertain0.5450.3690.000-11.963Likely Pathogenic0.445AmbiguousLikely Benign1.56Ambiguous0.22.32Destabilizing1.94Ambiguous1.02Destabilizing0.190Likely Benign-3.40Deleterious1.000Probably Damaging0.968Probably Damaging3.32Benign0.03Affected0.10450.1172-2-2-7.314.97
c.2753C>A
A918D
2D
AIThe SynGAP1 missense variant A918D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic outcome. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized independently predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence—including the high‑accuracy tools—points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation; there is no contradictory ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.632174Disordered0.891459Binding0.3170.8600.250-4.281Likely Benign0.445AmbiguousLikely Benign0.102Likely Benign-0.99Neutral0.961Probably Damaging0.721Possibly Damaging2.64Benign0.01Affected0.20370.24120-2-5.344.01
c.3059G>A
R1020Q
2D
AIThe SynGAP1 missense variant R1020Q is catalogued in gnomAD (6‑33443611‑G‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), while pathogenic predictions arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign trend: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus also indicates “Likely Benign.” No Foldetta stability analysis is available, so it does not influence the overall assessment. Based on the collective predictions, the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.972945Binding0.3400.7770.5006-33443611-G-A21.24e-6-3.753Likely Benign0.445AmbiguousLikely Benign0.137Likely Benign-2.19Neutral0.995Probably Damaging0.870Possibly Damaging2.52Benign0.00Affected3.7750.30500.2997111.0-28.06
c.973C>A
L325M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L325M is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are Rosetta, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and premPS. Two tools give uncertain results: Foldetta and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta as uncertain. No prediction or folding stability result is missing or inconclusive. Overall, the majority of tools (six pathogenic vs five benign) lean toward pathogenicity, but the high‑accuracy methods and several benign predictions introduce uncertainty. Thus, the variant is most likely pathogenic based on the collective evidence, and this assessment is not contradicted by any ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.352862Structured0.424577Uncertain0.9550.4360.000-6.725Likely Benign0.445AmbiguousLikely Benign0.22Likely Benign0.02.04Destabilizing1.13Ambiguous1.05Destabilizing0.306Likely Benign-0.86Neutral0.997Probably Damaging0.939Probably Damaging1.36Pathogenic0.01Affected0.09340.394242-1.918.03
c.2332A>G
N778D
2D
AIThe SynGAP1 missense variant N778D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.494003Structured0.853922Binding0.2880.8870.500-4.838Likely Benign0.446AmbiguousLikely Benign0.093Likely Benign-0.86Neutral0.843Possibly Damaging0.893Possibly Damaging4.21Benign0.15Tolerated0.18960.4528210.00.98
c.3515A>T
H1172L
2D
AIThe SynGAP1 missense variant H1172L is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign effect for H1172L, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.626927Disordered0.673805Binding0.4650.7580.625-0.545Likely Benign0.446AmbiguousLikely Benign0.426Likely Benign-2.30Neutral0.451Benign0.265Benign5.47Benign0.01Affected0.08150.5285-2-37.0-23.98
c.3548A>T
Y1183F
2D
AIThe SynGAP1 missense variant Y1183F is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy methods give a benign consensus: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign, with no Foldetta data. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.566480Disordered0.527818Binding0.5230.6520.500-3.527Likely Benign0.446AmbiguousLikely Benign0.124Likely Benign-1.42Neutral0.951Possibly Damaging0.514Possibly Damaging2.74Benign0.23Tolerated0.18910.2829734.1-16.00
c.3824G>T
R1275L
2D
AIThe SynGAP1 missense variant R1275L is listed in ClinVar as benign and is present in gnomAD (ID 6‑33447872‑G‑T). Functional prediction tools show a split: benign calls come from REVEL, ESM1b, FATHMM, AlphaMissense‑Optimized, and polyPhen2_HumVar, while pathogenic calls come from PROVEAN, polyPhen2_HumDiv, and SIFT. Grouping by agreement, the benign‑predicted tools outnumber the pathogenic ones (5 vs 3). High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign, and Foldetta results are unavailable. Overall, the computational evidence leans toward a benign effect, consistent with the ClinVar classification and showing no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.648219Disordered0.790317Binding0.7230.6970.500Likely Benign 16-33447872-G-T16.45e-7-6.052Likely Benign0.446AmbiguousLikely Benign0.117Likely Benign-4.04Deleterious0.800Possibly Damaging0.277Benign2.55Benign0.01Affected3.7750.16870.3181-3-28.3-43.03
c.1734G>C
E578D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant E578D is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) leans toward benign (2 benign vs 1 pathogenic votes), and Foldetta also predicts benign stability. No prediction or folding result is missing or inconclusive. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.059222Structured0.020971Uncertain0.9020.2400.000-4.366Likely Benign0.447AmbiguousLikely Benign0.46Likely Benign0.10.15Likely Benign0.31Likely Benign-0.05Likely Benign0.318Likely Benign-0.53Neutral0.989Probably Damaging0.979Probably Damaging-1.43Pathogenic0.33Tolerated0.15610.3554320.0-14.03
c.1734G>T
E578D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 E578D missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) resolves to benign (2 benign vs 1 pathogenic votes), and Foldetta predicts a benign stability change. No prediction or stability result is missing or inconclusive. Overall, the majority of evidence indicates that the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.059222Structured0.020971Uncertain0.9020.2400.000-4.366Likely Benign0.447AmbiguousLikely Benign0.46Likely Benign0.10.15Likely Benign0.31Likely Benign-0.05Likely Benign0.318Likely Benign-0.53Neutral0.989Probably Damaging0.979Probably Damaging-1.43Pathogenic0.33Tolerated0.15610.3554320.0-14.03
c.3268A>C
N1090H
2D
AIThe SynGAP1 missense variant N1090H is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) predict a pathogenic outcome. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status because no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.896620Disordered0.979886Binding0.3410.8871.000-3.744Likely Benign0.447AmbiguousLikely Benign0.094Likely Benign-1.42Neutral0.999Probably Damaging0.997Probably Damaging2.67Benign0.10Tolerated0.16040.7550210.323.04
c.3777C>G
I1259M
2D
AIThe SynGAP1 missense variant I1259M is catalogued in gnomAD (ID 6‑33446769‑C‑G) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score, whereas PolyPhen‑2 (HumDiv and HumVar) classify the change as pathogenic. The high‑accuracy AlphaMissense‑Optimized tool reports a benign effect, and the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates benign. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.494003Structured0.576405Binding0.8850.5740.2506-33446769-C-G21.24e-6-5.177Likely Benign0.447AmbiguousLikely Benign0.227Likely Benign1.35Neutral0.999Probably Damaging0.998Probably Damaging2.87Benign1.00Tolerated3.7750.05760.235812-2.618.03
c.475A>T
I159F
2D
AIThe SynGAP1 missense variant I159F is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors benign (2 benign vs. 1 pathogenic, 1 uncertain). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the balance of evidence, particularly from the high‑accuracy tools, points to a benign impact. This conclusion is not contradicted by any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.454136Structured0.529953Binding0.2780.7310.125-9.530Likely Pathogenic0.447AmbiguousLikely Benign0.200Likely Benign-1.41Neutral0.995Probably Damaging0.979Probably Damaging3.87Benign0.00Affected0.04900.244610-1.734.02
c.1519A>G
K507E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 K507E missense change is not listed in ClinVar and has no gnomAD allele, indicating it is not a common polymorphism. Functional prediction tools cluster into two groups: benign predictions come from Rosetta, PROVEAN, SIFT, and AlphaMissense‑Optimized, while pathogenic predictions arise from REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. Four tools give uncertain results: FoldX, Foldetta, premPS, and AlphaMissense‑Default. High‑accuracy assessments provide a mixed picture: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) leans pathogenic, and Foldetta remains uncertain. Overall, the majority of standard predictors favor a pathogenic effect, and the high‑accuracy consensus also tilts toward pathogenicity, though not decisively. Therefore, the variant is most likely pathogenic, and this assessment does not contradict ClinVar status because the variant is not yet reported there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.019401Structured0.262601Uncertain0.8850.2220.000-11.507Likely Pathogenic0.448AmbiguousLikely Benign0.70Ambiguous0.00.31Likely Benign0.51Ambiguous0.67Ambiguous0.536Likely Pathogenic-0.84Neutral0.999Probably Damaging0.995Probably Damaging-1.45Pathogenic0.21Tolerated0.25370.0488010.40.94
c.1777C>A
L593I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 L593I missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are FoldX, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Predictions that are uncertain are Rosetta, Foldetta, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta as uncertain. Overall, the majority of evidence points to a benign effect. The variant’s predicted benign status does not contradict its ClinVar status, which is currently unreported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.009728Structured0.110534Uncertain0.9410.1510.000-8.617Likely Pathogenic0.448AmbiguousLikely Benign2.16Destabilizing0.30.76Ambiguous1.46Ambiguous0.39Likely Benign0.169Likely Benign-1.59Neutral0.999Probably Damaging0.997Probably Damaging3.14Benign0.17Tolerated0.10710.3582220.70.00
c.3109A>C
I1037L
2D
AIThe SynGAP1 missense variant I1037L is not reported in ClinVar and is absent from gnomAD, indicating no known clinical or population evidence. Functional prediction tools uniformly favor a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. No tool predicts pathogenicity, and the only uncertain call comes from AlphaMissense‑Default. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports the variant as “Likely Benign.” High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that I1037L is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-2.563Likely Benign0.448AmbiguousLikely Benign0.074Likely Benign-0.46Neutral0.421Benign0.128Benign2.82Benign0.81Tolerated0.09390.430222-0.70.00
c.4016A>C
N1339T
2D
AIThe SynGAP1 missense variant N1339T is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors benign, and Foldetta results are unavailable. Based on the most reliable predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.771762Disordered0.977585Binding0.3960.6871.000-2.682Likely Benign0.448AmbiguousLikely Benign0.251Likely Benign-3.31Deleterious0.980Probably Damaging0.956Probably Damaging2.89Benign0.00Affected0.14430.7598002.8-13.00
c.2090G>C
W697S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant W697S is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are premPS, PROVEAN, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. Four tools (FoldX, Rosetta, Foldetta, AlphaMissense‑Default) give uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta as unavailable due to uncertainty. Overall, the majority of evidence points to a benign impact. This conclusion is not contradicted by any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.175930Structured0.400169Uncertain0.9450.2970.000-4.900Likely Benign0.449AmbiguousLikely Benign1.90Ambiguous0.11.58Ambiguous1.74Ambiguous1.13Destabilizing0.322Likely Benign-8.89Deleterious1.000Probably Damaging0.992Probably Damaging3.53Benign0.13Tolerated0.37380.1089-2-30.1-99.14
c.2291A>C
N764T
2D
AIThe SynGAP1 missense variant N764T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. No Foldetta stability analysis is available, so it does not influence the assessment. Overall, the majority of computational evidence points to a benign impact, and this is consistent with the lack of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.380708Structured0.919527Binding0.3050.8610.250-4.214Likely Benign0.449AmbiguousLikely Benign0.071Likely Benign-1.57Neutral0.975Probably Damaging0.850Possibly Damaging2.63Benign0.05Affected0.12720.5168002.8-13.00
c.2501T>G
M834R
2D
AIThe SynGAP1 missense variant M834R is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and FATHMM. AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) leans toward benign (2 benign vs. 1 pathogenic votes). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence indicates a benign impact, and this conclusion does not contradict any ClinVar annotation, as none exists for M834R.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.585406Disordered0.640801Binding0.2580.8630.375-2.621Likely Benign0.449AmbiguousLikely Benign0.148Likely Benign-2.44Neutral0.812Possibly Damaging0.284Benign2.43Pathogenic0.00Affected0.13100.08370-1-6.424.99
c.3095T>C
L1032P
2D
AIThe SynGAP1 missense variant L1032P has no ClinVar entry and is not reported in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and the SGM‑Consensus score all classify the change as benign or likely benign. AlphaMissense‑Optimized also predicts a benign outcome, whereas SIFT uniquely flags the variant as pathogenic. The AlphaMissense‑Default assessment is uncertain, and no Foldetta stability data are available. High‑accuracy analyses reinforce the benign consensus: AlphaMissense‑Optimized reports a benign effect, and the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates benign. Foldetta results are missing, so they do not influence the interpretation. Overall, the majority of computational evidence supports a benign classification, which is consistent with the absence of a ClinVar pathogenic annotation. Thus, the variant is most likely benign, and this conclusion does not contradict ClinVar status, as no ClinVar pathogenic claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.865454Disordered0.995318Binding0.3650.7350.500-2.560Likely Benign0.449AmbiguousLikely Benign0.142Likely Benign-0.71Neutral0.012Benign0.017Benign2.64Benign0.05Affected0.30240.2330-3-3-5.4-16.04
c.3101C>T
P1034L
2D
AIThe SynGAP1 missense variant P1034L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Tools that predict a pathogenic effect are PROVEAN and SIFT, while AlphaMissense‑Default is uncertain. The high‑accuracy AlphaMissense‑Optimized model classifies the variant as benign. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also yields a benign prediction (2 benign vs. 1 pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that P1034L is most likely benign, and this assessment does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.926919Disordered0.991713Binding0.3430.7520.625-4.204Likely Benign0.449AmbiguousLikely Benign0.067Likely Benign-3.24Deleterious0.001Benign0.005Benign2.53Benign0.01Affected0.22670.6937-3-35.416.04
c.326G>C
S109T
2D
AIThe SynGAP1 missense variant S109T is catalogued in gnomAD (6‑33432191‑G‑C) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all report benign or likely benign. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments confirm the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus, derived from the majority of the high‑accuracy predictors, is benign. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that S109T is most likely benign, and this assessment does not contradict any ClinVar status (none).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.622677Disordered0.669335Binding0.3280.8640.7506-33432191-G-C21.24e-6-4.065Likely Benign0.449AmbiguousLikely Benign0.090Likely Benign-1.19Neutral0.231Benign0.050Benign3.59Benign0.00Affected3.6150.15190.5212110.114.03
c.3413C>A
S1138Y
2D
AIThe SynGAP1 missense variant S1138Y is listed in ClinVar with an “Uncertain” significance and is present in gnomAD (ID 6‑33444448‑C‑A). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. High‑accuracy predictions from AlphaMissense‑Optimized and the SGM Consensus both indicate a benign outcome, while Foldetta data are missing. Overall, the balance of evidence—especially from the high‑accuracy tools—suggests that the variant is most likely benign. This benign prediction does not contradict the ClinVar status, which remains uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.891961Disordered0.738250Binding0.3460.8691.000Uncertain 16-33444448-C-A31.86e-6-6.610Likely Benign0.449AmbiguousLikely Benign0.391Likely Benign-2.51Deleterious0.997Probably Damaging0.996Probably Damaging5.41Benign0.05Affected4.3240.10340.5449-2-3-0.576.10
c.3699C>G
I1233M
2D
AIThe SynGAP1 missense variant I1233M is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign. Only SIFT predicts a pathogenic effect, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign outcome. High‑accuracy assessments further support this view: AlphaMissense‑Optimized is benign, and the SGM‑Consensus also indicates likely benign; Foldetta results are not available. Overall, the consensus of the available predictions points to a benign impact for I1233M, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation. Thus, the variant is most likely benign, and this assessment does not contradict ClinVar, which contains no pathogenic claim.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.525368Disordered0.564054Binding0.8810.5310.125-4.360Likely Benign0.449AmbiguousLikely Benign0.069Likely Benign-0.70Neutral0.437Benign0.108Benign2.70Benign0.04Affected0.05620.272621-2.618.03
c.1610C>A
A537E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A537E is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, premPS, PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as benign. No prediction or stability result is missing or inconclusive. Based on the overall consensus of the available tools, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.116183Structured0.037313Uncertain0.9280.3620.000-5.120Likely Benign0.450AmbiguousLikely Benign-0.14Likely Benign0.10.00Likely Benign-0.07Likely Benign0.23Likely Benign0.378Likely Benign-1.78Neutral0.987Probably Damaging0.838Possibly Damaging-1.04Pathogenic1.00Tolerated0.13470.15660-1-5.358.04
c.614T>C
I205T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I205T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, Rosetta, Foldetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; the remaining predictions (FoldX, premPS, AlphaMissense‑Default) are uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign; the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign effect; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, classifies the variant as benign. Taken together, the consensus of both general and high‑accuracy predictors indicates that I205T is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.264545Structured0.409933Uncertain0.8210.4140.125-6.869Likely Benign0.450AmbiguousLikely Benign0.65Ambiguous0.00.28Likely Benign0.47Likely Benign0.81Ambiguous0.118Likely Benign-2.19Neutral0.421Benign0.156Benign4.16Benign0.15Tolerated0.09330.05410-1-5.2-12.05
c.2359C>G
P787A
2D
AIThe SynGAP1 P787A missense variant has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized, whereas a majority (PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM) predict a pathogenic impact. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as pathogenic, and Foldetta results are unavailable. Overall, the balance of evidence—five pathogenic versus three benign predictions, with the SGM Consensus supporting pathogenicity—suggests that the variant is most likely pathogenic. This conclusion does not contradict ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.901269Disordered0.613211Binding0.3770.8990.750-4.542Likely Benign0.451AmbiguousLikely Benign0.242Likely Benign-4.23Deleterious0.999Probably Damaging0.998Probably Damaging2.48Pathogenic0.02Affected0.34250.44441-13.4-26.04
c.3274T>G
L1092V
2D
AIThe SynGAP1 missense variant L1092V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The high‑accuracy consensus (SGM‑Consensus) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.924947Disordered0.985431Binding0.3850.8901.000-4.906Likely Benign0.451AmbiguousLikely Benign0.034Likely Benign-0.36Neutral0.051Benign0.037Benign2.79Benign0.37Tolerated0.16580.3912210.4-14.03
c.3433A>T
N1145Y
2D
AIThe SynGAP1 missense variant N1145Y is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include ESM1b, FATHMM, and AlphaMissense‑Optimized, whereas REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), and SIFT uniformly predict a pathogenic impact. AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields benign, while Foldetta results are unavailable. Overall, the majority of conventional tools predict pathogenicity, but the high‑accuracy consensus leans benign. Based on the collective evidence, the variant is most likely pathogenic, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.922952Disordered0.722723Binding0.2840.8501.000-2.945Likely Benign0.451AmbiguousLikely Benign0.543Likely Pathogenic-4.07Deleterious0.999Probably Damaging0.998Probably Damaging5.40Benign0.01Affected0.06220.6337-2-22.249.07
c.703T>A
S235T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S235T is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Optimized. Only ESM1b predicts a pathogenic outcome, while FoldX, Rosetta, and AlphaMissense‑Default are uncertain. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign majority; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also predicts benign. No prediction or folding result is missing or inconclusive. Based on the overall consensus of the available tools, the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
PH0.250310Structured0.319150Uncertain0.7430.3310.000-9.422Likely Pathogenic0.451AmbiguousLikely Benign0.80Ambiguous0.0-0.54Ambiguous0.13Likely Benign0.21Likely Benign0.453Likely Benign-2.02Neutral0.057Benign0.020Benign5.75Benign0.13Tolerated0.16740.6337110.114.03
c.2324G>C
R775P
2D
AIThe SynGAP1 missense variant R775P is listed in ClinVar (ID 2959355) as Benign and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Two tools (polyPhen‑2 HumDiv and HumVar) predict a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, the SGM‑Consensus also indicating a likely benign status, and Foldetta’s protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, which is consistent with the ClinVar classification and does not contradict the reported status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.444081Structured0.895337Binding0.3200.8960.250Benign 2-5.072Likely Benign0.452AmbiguousLikely Benign0.168Likely Benign-0.79Neutral0.971Probably Damaging0.944Probably Damaging4.13Benign0.07Tolerated3.6460.18910.4834-202.9-59.07
c.310C>G
R104G
2D
AIThe SynGAP1 missense variant R104G is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for R104G, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.678998Binding0.3390.8690.625-2.373Likely Benign0.452AmbiguousLikely Benign0.109Likely Benign-0.90Neutral0.835Possibly Damaging0.165Benign4.03Benign0.00Affected0.31110.3625-3-24.1-99.14
c.3383G>A
G1128E
2D
AIThe SynGAP1 missense variant G1128E is present in gnomAD (6‑33443935‑G‑A) and has no ClinVar entry. In silico predictors that agree on a benign effect include REVEL, PROVEAN, PolyPhen‑2 HumDiv, PolyPhen‑2 HumVar, SIFT, ESM1b, and FATHMM. The SGM‑Consensus, which is a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also classifies the variant as likely benign. High‑accuracy tools reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus itself is a high‑accuracy majority vote. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, did not provide a result for this variant, so its stability impact remains unknown. Overall, the computational evidence overwhelmingly supports a benign classification, and this is consistent with the absence of a pathogenic ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.896620Disordered0.865136Binding0.3090.9110.8756-33443935-G-A16.70e-7-5.580Likely Benign0.452AmbiguousLikely Benign0.235Likely Benign-0.24Neutral0.002Benign0.008Benign4.43Benign1.00Tolerated4.3240.16100.4497-20-3.172.06
c.3983G>T
R1328L
2D
AIThe SynGAP1 missense variant R1328L is listed in gnomAD (ID 6‑33451857‑G‑T) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; a Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.911775Binding0.3600.7620.8756-33451857-G-T-3.233Likely Benign0.452AmbiguousLikely Benign0.038Likely Benign-1.94Neutral0.784Possibly Damaging0.145Benign4.08Benign0.01Affected3.7750.19780.3555-2-38.3-43.03
c.182A>C
E61A
2D
AIThe SynGAP1 missense variant E61A is listed in ClinVar (ID 3767543.0) with an *Uncertain* clinical significance and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign, while Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the current ClinVar status of uncertainty.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.352862Structured0.477329Uncertain0.5180.6990.125Uncertain 1-5.235Likely Benign0.453AmbiguousLikely Benign0.074Likely Benign-1.52Neutral0.458Possibly Damaging0.678Possibly Damaging4.12Benign0.00Affected0.44990.58780-15.3-58.04
c.1994A>C
Y665S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Y665S is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. The remaining tools (FoldX, Rosetta, Foldetta, premPS, AlphaMissense‑Default) give uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) leans pathogenic, and Foldetta is uncertain (treated as unavailable). Overall, the balance of evidence, particularly the pathogenic signal from the SGM Consensus and the equal split among standard predictors, indicates that the variant is most likely pathogenic. This conclusion does not contradict ClinVar status, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.098513Structured0.086641Uncertain0.9220.3610.000-9.110Likely Pathogenic0.453AmbiguousLikely Benign1.24Ambiguous0.21.40Ambiguous1.32Ambiguous0.87Ambiguous0.202Likely Benign-2.50Deleterious1.000Probably Damaging0.994Probably Damaging3.55Benign0.62Tolerated0.39950.1793-3-20.5-76.10
c.2264T>G
M755R
2D
AIThe SynGAP1 missense variant M755R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from multiple prediction algorithms and high‑accuracy tools indicates that the M755R variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.490133Structured0.783855Binding0.3360.8730.375-4.247Likely Benign0.453AmbiguousLikely Benign0.104Likely Benign-2.06Neutral0.468Possibly Damaging0.206Benign2.63Benign0.18Tolerated0.14070.08370-1-6.424.99
c.2302G>A
D768N
2D
AIThe SynGAP1 missense variant D768N is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33442460‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus is “Likely Benign,” and Foldetta data are unavailable. Overall, the consensus of available predictions indicates that the variant is most likely benign, which does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.332115Structured0.928237Binding0.3140.8770.250Uncertain 16-33442460-G-A22.57e-6-6.892Likely Benign0.453AmbiguousLikely Benign0.048Likely Benign-0.77Neutral0.106Benign0.009Benign4.07Benign0.96Tolerated3.6460.11780.7843120.0-0.98
c.2501T>A
M834K
2D
AIThe SynGAP1 missense variant M834K is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and FATHMM, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also predicts benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing clinical database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.585406Disordered0.640801Binding0.2580.8630.375-3.154Likely Benign0.453AmbiguousLikely Benign0.154Likely Benign-2.21Neutral0.369Benign0.150Benign2.43Pathogenic0.00Affected0.11310.06880-1-5.8-3.02
c.651G>C
E217D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant E217D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all classify the change as benign. The only inconclusive result comes from AlphaMissense‑Default, which is listed as uncertain. High‑accuracy assessments corroborate this benign profile: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is “Likely Benign,” and Foldetta (combining FoldX‑MD and Rosetta outputs) also reports a benign outcome. No pathogenic predictions are present. Therefore, based on the available computational evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.278302Structured0.404912Uncertain0.8230.2840.000-2.268Likely Benign0.453AmbiguousLikely Benign0.24Likely Benign0.3-0.07Likely Benign0.09Likely Benign-0.34Likely Benign0.276Likely Benign0.66Neutral0.014Benign0.007Benign5.85Benign0.85Tolerated3.41130.20660.5976230.0-14.03
c.651G>T
E217D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant E217D is present in gnomAD (6‑33435293‑G‑T) but has no ClinVar entry. Functional prediction tools uniformly classify it as benign: REVEL, FoldX, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and Foldetta all report benign or benign‑like outcomes. No tool predicts pathogenicity. The high‑accuracy consensus methods corroborate this: AlphaMissense‑Optimized indicates benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields “Likely Benign”; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also reports benign. AlphaMissense‑Default remains uncertain and is treated as unavailable. Overall, the evidence strongly supports a benign effect for E217D, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.278302Structured0.404912Uncertain0.8230.2840.0006-33435293-G-T16.20e-7-2.268Likely Benign0.453AmbiguousLikely Benign0.24Likely Benign0.3-0.07Likely Benign0.09Likely Benign-0.34Likely Benign0.276Likely Benign0.66Neutral0.014Benign0.007Benign5.85Benign0.85Tolerated3.41130.20660.5976230.0-14.03
c.3014G>C
S1005T
2D
AIThe SynGAP1 missense variant S1005T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.812494Disordered0.936602Binding0.2610.8970.750-6.015Likely Benign0.454AmbiguousLikely Benign0.120Likely Benign-1.30Neutral0.992Probably Damaging0.987Probably Damaging2.66Benign0.00Affected0.16000.4937110.114.03
c.3392C>A
P1131H
2D
AIThe SynGAP1 missense variant P1131H is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus as benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta) has no available result for this variant. Overall, the balance of evidence leans toward a benign classification, and this assessment does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.919029Disordered0.855155Binding0.3600.8990.750-5.207Likely Benign0.454AmbiguousLikely Benign0.357Likely Benign-3.50Deleterious0.971Probably Damaging0.750Possibly Damaging5.24Benign0.00Affected0.15190.55460-2-1.640.02
c.353T>C
M118T
2D
AIThe SynGAP1 missense variant M118T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The high‑accuracy consensus (SGM‑Consensus) also indicates a likely benign classification, and AlphaMissense‑Optimized independently predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Overall, the evidence from multiple independent predictors and the high‑accuracy consensus strongly supports a benign impact. This conclusion is consistent with the lack of any ClinVar pathogenic annotation, so there is no contradiction with existing clinical database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.694846Disordered0.676867Binding0.3300.8830.500-2.468Likely Benign0.454AmbiguousLikely Benign0.217Likely Benign-2.41Neutral0.396Benign0.067Benign3.86Benign0.08Tolerated0.22070.2237-1-1-2.6-30.09
c.2170G>A
A724T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 A724T missense variant is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that indicate a benign effect include REVEL, premPS, and AlphaMissense‑Optimized. Those that predict a pathogenic effect comprise PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. Predictions that are inconclusive are AlphaMissense‑Default, FoldX, Rosetta, and Foldetta. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the majority of evaluated tools (seven pathogenic vs. three benign) suggest a pathogenic impact. This conclusion is consistent with the lack of ClinVar annotation, as there is no existing classification to contradict. Thus, the variant is most likely pathogenic based on current predictive evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.476583Structured0.458050Uncertain0.9230.4830.250-8.047Likely Pathogenic0.456AmbiguousLikely Benign0.95Ambiguous0.11.10Ambiguous1.03Ambiguous0.40Likely Benign0.273Likely Benign-2.87Deleterious0.998Probably Damaging0.993Probably Damaging2.09Pathogenic0.01Affected0.11490.589710-2.530.03
c.2434C>T
P812S
2D
AIThe SynGAP1 missense variant P812S is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33442986‑C‑T). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default remains uncertain, and no Foldetta stability result is available. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta data are missing. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.414856Structured0.842442Binding0.3880.9010.125Uncertain 16-33442986-C-T16.20e-7-5.689Likely Benign0.456AmbiguousLikely Benign0.162Likely Benign-0.62Neutral0.999Probably Damaging0.966Probably Damaging2.89Benign0.95Tolerated4.3240.34170.56991-10.8-10.04
c.386C>T
S129L
2D
AIThe SynGAP1 missense variant S129L is catalogued in gnomAD (ID 6‑33432251‑C‑T) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote) all report benign or likely benign. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors benign. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the preponderance of evidence indicates that S129L is most likely benign, and this assessment does not contradict any ClinVar status, as none is reported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.517562Disordered0.713635Binding0.3110.8800.6256-33432251-C-T16.20e-7-4.487Likely Benign0.456AmbiguousLikely Benign0.256Likely Benign-0.18Neutral0.000Benign0.000Benign4.14Benign0.05Affected3.7440.08850.5249-2-34.626.08
c.604G>C
E202Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 E202Q missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are polyPhen‑2 (HumDiv and HumVar) and SIFT. Two tools, ESM1b and AlphaMissense‑Default, return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a 2‑to‑2 split. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the lack of ClinVar annotation and gnomAD presence, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
PH0.363090Structured0.429450Uncertain0.7120.4150.125-7.129In-Between0.456AmbiguousLikely Benign-0.16Likely Benign0.00.23Likely Benign0.04Likely Benign-0.13Likely Benign0.175Likely Benign-1.39Neutral0.995Probably Damaging0.747Possibly Damaging4.07Benign0.02Affected0.09490.6792220.0-0.98
c.1091C>T
P364L
2D
3DClick to see structure in 3D Viewer
AISynGAP1 P364L is reported in gnomAD (ID 6‑33437996‑C‑T) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, premPS, SIFT, AlphaMissense‑Optimized, and Foldetta; pathogenic predictions come from PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Three tools—FoldX, Rosetta, and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments further clarify the picture: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates likely pathogenic, and Foldetta, which integrates FoldX‑MD and Rosetta outputs, predicts benign. Overall, the balance of evidence slightly favors a benign effect, and this conclusion does not contradict any ClinVar classification because none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicC20.390993Structured0.439474Uncertain0.9420.5900.2506-33437996-C-T-10.620Likely Pathogenic0.457AmbiguousLikely Benign0.88Ambiguous0.9-0.73Ambiguous0.08Likely Benign0.31Likely Benign0.387Likely Benign-7.78Deleterious1.000Probably Damaging0.997Probably Damaging1.54Pathogenic0.18Tolerated3.39200.22000.6207-3-35.416.04
c.2366C>T
P789L
2D
AIThe SynGAP1 P789L missense variant has no ClinVar entry and is not reported in gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, ESM1b, and AlphaMissense‑Optimized, while pathogenic predictions arise from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. AlphaMissense‑Default remains uncertain. High‑accuracy assessments further refine the picture: AlphaMissense‑Optimized predicts benign, whereas the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—leans pathogenic (2 pathogenic vs. 1 benign). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence (five pathogenic vs. three benign predictions, with the SGM Consensus supporting pathogenicity) indicates that P789L is most likely pathogenic, and this assessment does not contradict any ClinVar status, as none is currently assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.963420Disordered0.541575Binding0.3980.9030.750-4.623Likely Benign0.457AmbiguousLikely Benign0.303Likely Benign-5.91Deleterious1.000Probably Damaging0.999Probably Damaging2.02Pathogenic0.00Affected0.19580.4866-3-35.416.04
c.2714G>A
R905H
2D
AIThe SynGAP1 missense variant R905H is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443266‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta’s protein‑folding stability analysis is unavailable for this variant. Overall, the majority of computational evidence points to a benign effect, which does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.618085Binding0.2910.9200.250Uncertain 16-33443266-G-A84.96e-6-4.182Likely Benign0.457AmbiguousLikely Benign0.192Likely Benign-1.11Neutral1.000Probably Damaging0.991Probably Damaging2.59Benign0.09Tolerated3.7750.26580.2279201.3-19.05
c.3129G>C
R1043S
2D
AIThe SynGAP1 missense variant R1043S is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools cluster into two groups: benign predictions include PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions come from REVEL and SIFT. AlphaMissense‑Default is uncertain, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized scores benign, SGM‑Consensus is likely benign, and Foldetta results are unavailable. Taken together, the majority of evidence points to a benign impact for R1043S. This conclusion is consistent with the absence of a ClinVar assertion, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.954069Binding0.2990.8530.625-3.223Likely Benign0.457AmbiguousLikely Benign0.509Likely Pathogenic-2.10Neutral0.036Benign0.018Benign5.42Benign0.00Affected3.7750.27270.4628-103.7-69.11
c.3129G>T
R1043S
2D
AIThe SynGAP1 missense variant R1043S is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443681‑G‑T). Prediction tools that agree on a benign effect include PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict a pathogenic effect are REVEL and SIFT. AlphaMissense‑Default remains uncertain, and no Foldetta stability result is available. High‑accuracy assessments: AlphaMissense‑Optimized classifies the variant as benign; the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign outcome; Foldetta data are missing, so it does not contribute to the evaluation. Based on the collective predictions, the variant is most likely benign, which is consistent with its ClinVar “Uncertain” classification and does not contradict the available evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.954069Binding0.2990.8530.625Uncertain 16-33443681-G-T21.24e-6-3.223Likely Benign0.457AmbiguousLikely Benign0.509Likely Pathogenic-2.10Neutral0.036Benign0.018Benign5.42Benign0.00Affected3.7750.27270.4628-103.7-69.11
c.3821G>T
R1274L
2D
AIThe SynGAP1 missense variant R1274L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also predicts benign, while Foldetta results are unavailable. Overall, the majority of reliable predictors and the high‑accuracy consensus favor a benign classification. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.613573Disordered0.779985Binding0.7460.6880.625-5.318Likely Benign0.457AmbiguousLikely Benign0.165Likely Benign-4.48Deleterious0.997Probably Damaging0.993Probably Damaging2.50Benign0.01Affected0.16570.3006-3-28.3-43.03
c.400A>G
S134G
2D
AIThe SynGAP1 missense variant S134G is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus (SGM‑Consensus) is derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yielding a “Likely Benign” classification. AlphaMissense‑Optimized also reports a benign prediction. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from multiple independent predictors and the high‑accuracy consensus indicates that the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.447574Structured0.695837Binding0.3330.8980.250-6.722Likely Benign0.457AmbiguousLikely Benign0.120Likely Benign-2.19Neutral0.034Benign0.035Benign3.84Benign0.00Affected0.22680.4008100.4-30.03
c.1769G>C
S590T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S590T is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and ESM1b. Two tools (premPS and AlphaMissense‑Default) return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) as benign. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.022667Structured0.088943Uncertain0.9180.1990.000-12.472Likely Pathogenic0.458AmbiguousLikely Benign0.23Likely Benign0.10.42Likely Benign0.33Likely Benign0.64Ambiguous0.459Likely Benign-2.89Deleterious0.183Benign0.050Benign3.15Benign0.08Tolerated0.14200.5723110.114.03
c.3079A>G
N1027D
2D
AIThe SynGAP1 missense variant N1027D is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in‑silico predictors indicates a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all score benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also classifies it as likely benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, and AlphaMissense‑Default remains uncertain. High‑accuracy tools reinforce the benign assessment: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence supports a benign classification, and this is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.831250Disordered0.994357Binding0.3470.7450.500-2.891Likely Benign0.458AmbiguousLikely Benign0.073Likely Benign-1.27Neutral0.649Possibly Damaging0.353Benign2.74Benign0.27Tolerated0.18540.4004210.00.98
c.1406C>T
A469V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 A469V missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect comprise FoldX, Rosetta, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and Foldetta; premPS and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic, and Foldetta predicts pathogenic. With seven tools supporting pathogenicity versus four supporting benignity, the variant is most likely pathogenic, and this assessment does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.278302Structured0.343926Uncertain0.9100.2760.000-8.858Likely Pathogenic0.459AmbiguousLikely Benign2.30Destabilizing0.42.66Destabilizing2.48Destabilizing-0.77Ambiguous0.426Likely Benign0.26Neutral0.997Probably Damaging0.976Probably Damaging-1.20Pathogenic0.60Tolerated0.08270.5421002.428.05
c.169C>T
L57F
2D
AIThe SynGAP1 missense variant L57F (ClinVar ID 1973575.0) is listed as “Uncertain” in ClinVar and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion aligns with the ClinVar “Uncertain” status, as it does not contradict the current classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.254060Structured0.481044Uncertain0.5540.6420.000Uncertain 2-5.096Likely Benign0.459AmbiguousLikely Benign0.051Likely Benign-0.78Neutral0.824Possibly Damaging0.879Possibly Damaging3.96Benign0.00Affected4.3210.06790.335520-1.034.02
c.1999A>C
I667L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I667L is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. The remaining tools—FoldX, Rosetta, Foldetta, premPS, and AlphaMissense‑Default—return uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta as uncertain. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation and gnomAD presence, indicating no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.142424Structured0.083597Uncertain0.9270.3790.000-10.452Likely Pathogenic0.459AmbiguousLikely Benign0.93Ambiguous0.20.72Ambiguous0.83Ambiguous0.75Ambiguous0.300Likely Benign-1.97Neutral0.457Possibly Damaging0.392Benign3.36Benign0.13Tolerated0.09800.314522-0.70.00
c.2286C>A
D762E
2D
AIThe SynGAP1 D762E missense variant is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also predicts benign, and Foldetta results are unavailable. Overall, the majority of high‑confidence predictions lean toward a benign impact, and there is no ClinVar annotation to contradict this assessment. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.405110Structured0.910475Binding0.3080.8590.125-4.332Likely Benign0.459AmbiguousLikely Benign0.144Likely Benign-1.59Neutral0.994Probably Damaging0.891Possibly Damaging2.18Pathogenic0.05Affected0.19110.8236320.014.03
c.2286C>G
D762E
2D
AIThe SynGAP1 D762E missense variant is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also predicts benign, and Foldetta results are unavailable. Overall, the majority of high‑confidence predictions lean toward a benign impact, and there is no ClinVar annotation to contradict this assessment. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.405110Structured0.910475Binding0.3080.8590.125-4.332Likely Benign0.459AmbiguousLikely Benign0.144Likely Benign-1.59Neutral0.994Probably Damaging0.891Possibly Damaging2.18Pathogenic0.05Affected0.19110.8236320.014.03
c.2633C>T
T878I
2D
AIThe SynGAP1 missense variant T878I is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect. **Benign:** REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized. **Pathogenic:** polyPhen‑2 HumDiv, SIFT. AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus itself is benign; Foldetta results are unavailable. Overall, the computational evidence overwhelmingly points to a benign effect, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.622677Disordered0.628767Binding0.2880.8780.250-6.247Likely Benign0.459AmbiguousLikely Benign0.055Likely Benign-1.99Neutral0.761Possibly Damaging0.398Benign2.63Benign0.00Affected0.09800.65020-15.212.05
c.3314G>T
R1105L
2D
AIThe SynGAP1 missense variant R1105L is not reported in ClinVar and is present in gnomAD (ID 6‑33443866‑G‑T). Functional prediction tools cluster into two groups: benign predictions come from REVEL, polyPhen‑2 HumVar, SIFT, ESM1b, and AlphaMissense‑Optimized; pathogenic predictions come from PROVEAN, polyPhen‑2 HumDiv, and FATHMM. AlphaMissense‑Default remains uncertain. High‑accuracy assessments further refine the picture: AlphaMissense‑Optimized classifies the variant as benign, whereas the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—labels it pathogenic. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, did not provide a result for this residue, so its stability impact is unavailable. Overall, the balance of evidence leans toward a benign effect, with no conflict with ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.901269Disordered0.954396Binding0.3300.8630.8756-33443866-G-T-4.031Likely Benign0.459AmbiguousLikely Benign0.125Likely Benign-3.51Deleterious0.677Possibly Damaging0.168Benign2.46Pathogenic0.19Tolerated3.7750.17340.5373-2-38.3-43.03
c.2423T>G
V808G
2D
AIThe SynGAP1 V808G missense variant is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, SIFT, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic. Foldetta results are unavailable. Overall, the majority of individual predictors (five benign vs. three pathogenic) support a benign classification, and this is not contradicted by any ClinVar annotation. Thus, based on the available predictions, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.699094Disordered0.856438Binding0.2890.9030.500-6.635Likely Benign0.460AmbiguousLikely Benign0.268Likely Benign-2.94Deleterious0.069Benign0.135Benign2.27Pathogenic0.00Affected0.19250.3336-1-3-4.6-42.08
c.2630T>A
L877Q
2D
AIThe SynGAP1 missense variant L877Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT uniformly predict a pathogenic impact. AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, SGM‑Consensus is Likely Benign, and Foldetta (which integrates FoldX‑MD and Rosetta outputs) is not available for this variant. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.653063Disordered0.634010Binding0.2650.8750.250-5.919Likely Benign0.460AmbiguousLikely Benign0.152Likely Benign-1.58Neutral0.986Probably Damaging0.876Possibly Damaging2.57Benign0.03Affected0.12080.0919-2-2-7.314.97
c.3011A>C
H1004P
2D
AIThe SynGAP1 missense variant H1004P is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, SIFT, ESM1b, FATHMM, and the high‑accuracy AlphaMissense‑Optimized model. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. The SGM Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a benign majority vote. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation; there is no contradiction between the predictions and ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.808535Disordered0.943707Binding0.2710.9010.750-3.686Likely Benign0.460AmbiguousLikely Benign0.236Likely Benign-2.69Deleterious0.999Probably Damaging0.998Probably Damaging2.72Benign0.18Tolerated0.20760.46430-21.6-40.02
c.3046G>A
D1016N
2D
AIThe SynGAP1 missense variant D1016N is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. High‑accuracy assessments therefore indicate a benign prediction: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and no Foldetta data is available. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.801317Disordered0.944705Binding0.3230.8110.625-3.674Likely Benign0.460AmbiguousLikely Benign0.123Likely Benign-2.12Neutral0.856Possibly Damaging0.723Possibly Damaging2.50Benign0.01Affected0.19890.7529210.0-0.98
c.3244C>A
Q1082K
2D
AIThe SynGAP1 missense variant Q1082K is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all score benign, and AlphaMissense‑Optimized also predicts benign. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. No tools predict pathogenicity, and AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, SGM‑Consensus is Likely Benign, while Foldetta results are unavailable. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.819762Disordered0.979325Binding0.3470.8960.875-4.488Likely Benign0.460AmbiguousLikely Benign0.087Likely Benign-1.13Neutral0.224Benign0.058Benign4.19Benign0.12Tolerated0.20080.497211-0.40.04
c.2173C>G
L725V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L725V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools show a split: benign calls come from REVEL and AlphaMissense‑Optimized, while pathogenic calls are made by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. The remaining methods (FoldX, Rosetta, Foldetta, premPS, AlphaMissense‑Default) are inconclusive. High‑accuracy assessments further clarify the picture: AlphaMissense‑Optimized predicts a benign effect, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely pathogenic outcome, and Foldetta provides no definitive stability change. Overall, the majority of evidence points toward a pathogenic impact, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Pathogenic0.557691Disordered0.455613Uncertain0.9110.4910.625-8.291Likely Pathogenic0.461AmbiguousLikely Benign1.76Ambiguous0.11.87Ambiguous1.82Ambiguous0.77Ambiguous0.183Likely Benign-2.69Deleterious0.993Probably Damaging0.992Probably Damaging1.36Pathogenic0.01Affected0.17390.3977210.4-14.03
c.3109A>G
I1037V
2D
AIThe SynGAP1 missense variant I1037V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that I1037V is most likely benign, and this conclusion is not contradicted by ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.939629Disordered0.986140Binding0.3090.7740.625-2.326Likely Benign0.461AmbiguousLikely Benign0.085Likely Benign-0.09Neutral0.421Benign0.128Benign2.76Benign0.93Tolerated0.12290.398543-0.3-14.03
c.3218C>G
S1073C
2D
AISynGAP1 missense variant S1073C is recorded in gnomAD (ID 6‑33443770‑C‑G) but has no ClinVar submission. Functional prediction tools show mixed results: benign calls come from REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized, whereas pathogenic calls are made by polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. The AlphaMissense‑Default score is uncertain. A consensus from the SGM framework (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because the votes are split. High‑accuracy methods give a benign prediction from AlphaMissense‑Optimized; the SGM Consensus remains ambiguous, and Foldetta stability analysis is unavailable. Consequently, the evidence does not strongly favor either outcome. The variant is most likely of uncertain significance, with no contradiction to ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.916840Disordered0.985818Binding0.3130.9050.7506-33443770-C-G16.23e-7-8.862Likely Pathogenic0.461AmbiguousLikely Benign0.137Likely Benign-1.52Neutral0.997Probably Damaging0.840Possibly Damaging3.81Benign0.00Affected3.7750.13430.6088-103.316.06
c.3567G>C
E1189D
2D
AIThe SynGAP1 missense variant E1189D (gnomAD ID 6-33444602‑G‑C) is listed in ClinVar as Benign (ClinVar ID 833989.0). In silico predictors that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score (Likely Benign). Predictors that indicate a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. The high‑accuracy AlphaMissense‑Optimized tool classifies the variant as benign, and the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also favors a benign outcome. No Foldetta stability assessment is available for this residue. Overall, the majority of evidence points to a benign impact, and this conclusion aligns with the ClinVar designation, showing no contradiction.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.562014Disordered0.466885Uncertain0.7040.6230.625Likely Benign 16-33444602-G-C31.86e-6-3.582Likely Benign0.461AmbiguousLikely Benign0.359Likely Benign-1.42Neutral0.992Probably Damaging0.989Probably Damaging5.30Benign0.25Tolerated3.8240.13930.2610320.0-14.03
c.3567G>T
E1189D
2D
AIThe SynGAP1 missense variant E1189D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy methods reinforce the benign prediction: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign, while Foldetta data are missing. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.562014Disordered0.466885Uncertain0.7040.6230.625-3.582Likely Benign0.461AmbiguousLikely Benign0.359Likely Benign-1.42Neutral0.992Probably Damaging0.989Probably Damaging5.30Benign0.25Tolerated3.8240.13930.2610320.0-14.03
c.1606T>A
L536M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 L536M missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include FoldX, PROVEAN, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are REVEL, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. The remaining tools—Rosetta, Foldetta, premPS, and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the majority of evidence points toward a pathogenic impact, and this conclusion does not contradict any ClinVar annotation because no ClinVar status exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.137348Structured0.042188Uncertain0.9310.3410.000-10.124Likely Pathogenic0.462AmbiguousLikely Benign0.37Likely Benign0.11.18Ambiguous0.78Ambiguous0.93Ambiguous0.571Likely Pathogenic-1.94Neutral1.000Probably Damaging1.000Probably Damaging-1.32Pathogenic0.01Affected0.09370.329942-1.918.03
c.1885G>A
V629I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V629I is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, AlphaMissense‑Optimized, and FATHMM. Those that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar) and SIFT, with ESM1b also indicating pathogenicity. AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign, and Foldetta also predicts a benign outcome. Taken together, the preponderance of evidence supports a benign classification for V629I, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.040537Structured0.034796Uncertain0.9700.2360.000-9.876Likely Pathogenic0.462AmbiguousLikely Benign-0.22Likely Benign0.10.37Likely Benign0.08Likely Benign0.21Likely Benign0.305Likely Benign-1.00Neutral0.975Probably Damaging0.958Probably Damaging3.26Benign0.04Affected0.06500.2919430.314.03
c.2036T>A
F679Y
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant F679Y is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. Two tools give uncertain results: premPS and AlphaMissense‑Default. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) resolves to benign; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also predicts benign. Overall, the majority of evidence indicates that F679Y is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.222385Structured0.129316Uncertain0.7000.3200.000-5.842Likely Benign0.462AmbiguousLikely Benign0.48Likely Benign0.20.13Likely Benign0.31Likely Benign0.71Ambiguous0.315Likely Benign-2.71Deleterious0.993Probably Damaging0.952Probably Damaging3.47Benign0.14Tolerated0.13060.195473-4.116.00
c.3286G>C
E1096Q
2D
AIThe SynGAP1 missense variant E1096Q is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (both HumDiv and HumVar) predict a pathogenic outcome. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as likely benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from multiple prediction algorithms and high‑accuracy tools suggests that E1096Q is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.976475Binding0.3080.8581.000-3.134Likely Benign0.462AmbiguousLikely Benign0.142Likely Benign-1.08Neutral0.954Possibly Damaging0.654Possibly Damaging2.73Benign0.29Tolerated0.15270.7459220.0-0.98
c.268G>A
V90M
2D
AIThe SynGAP1 missense variant V90M is listed in gnomAD (6‑33425876‑G‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status, as none is reported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.570702Disordered0.542047Binding0.3430.8730.5006-33425876-G-A16.20e-7-5.017Likely Benign0.463AmbiguousLikely Benign0.053Likely Benign-0.15Neutral0.872Possibly Damaging0.162Benign3.98Benign0.00Affected4.3210.12210.439312-2.332.06
c.2776T>G
S926A
2D
AIThe SynGAP1 missense variant S926A is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of reliable predictions indicate a benign impact, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.461924Structured0.981753Binding0.2950.8540.250-3.042Likely Benign0.463AmbiguousLikely Benign0.186Likely Benign-2.13Neutral0.992Probably Damaging0.987Probably Damaging1.59Pathogenic0.00Affected0.46570.4488112.6-16.00
c.3074A>T
Q1025L
2D
AIThe SynGAP1 missense variant Q1025L is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.993410Binding0.3630.7460.500-6.460Likely Benign0.463AmbiguousLikely Benign0.117Likely Benign-2.48Neutral0.901Possibly Damaging0.534Possibly Damaging2.70Benign0.05Affected0.07980.5497-2-27.3-14.97
c.416G>C
S139T
2D
AIThe SynGAP1 missense variant S139T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The high‑accuracy consensus (SGM‑Consensus) also indicates a likely benign classification, and AlphaMissense‑Optimized independently predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, was not available for this variant. Overall, the majority of computational evidence supports a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.553315Disordered0.600637Binding0.3530.9000.250-4.518Likely Benign0.463AmbiguousLikely Benign0.122Likely Benign-1.70Neutral0.034Benign0.023Benign4.13Benign0.25Tolerated0.16550.4416110.114.03
c.1123G>T
G375W
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G375W is not reported in ClinVar (ClinVar ID None) but is present in gnomAD (ID 6‑33438028‑G‑T). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, and AlphaMissense‑Optimized. Those that predict a pathogenic impact are FoldX, Rosetta, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) as pathogenic. Overall, the majority of evidence, including the high‑accuracy tools, points to a pathogenic effect for G375W. This conclusion is consistent with the absence of a ClinVar classification, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.604312Disordered0.428340Uncertain0.3010.8360.6256-33438028-G-T-9.654Likely Pathogenic0.464AmbiguousLikely Benign4.33Destabilizing2.07.01Destabilizing5.67Destabilizing0.22Likely Benign0.450Likely Benign-1.26Neutral0.992Probably Damaging0.869Possibly Damaging1.31Pathogenic0.01Affected4.32120.09920.4368-2-7-0.5129.16
c.1765A>G
I589V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 I589V missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are REVEL, polyPhen‑2 (HumDiv and HumVar), and FATHMM. The remaining tools—FoldX, Rosetta, Foldetta, premPS, and AlphaMissense‑Default—return uncertain or inconclusive results. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is benign; and Foldetta is uncertain. Taken together, the majority of evidence, including the high‑accuracy predictions, points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing clinical database.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.018415Structured0.084536Uncertain0.9270.2140.000-6.966Likely Benign0.464AmbiguousLikely Benign0.98Ambiguous0.00.78Ambiguous0.88Ambiguous0.96Ambiguous0.535Likely Pathogenic-1.00Neutral0.969Probably Damaging0.960Probably Damaging-1.50Pathogenic0.31Tolerated0.13560.356843-0.3-14.03
c.2240T>A
V747E
2D
AIThe SynGAP1 missense variant V747E is evaluated by multiple in silico tools. ClinVar has no entry for this change, and it is not reported in gnomAD. Consensus from the SGM‑Consensus algorithm classifies the variant as Likely Benign. When grouping predictions by agreement, benign calls come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic calls arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates Likely Benign, and no Foldetta stability data are available. Overall, the majority of evidence points to a benign effect, and this conclusion does not conflict with the absence of a ClinVar classification. Based on the aggregate predictions, the variant is most likely benign, and this assessment does not contradict the ClinVar status, which currently has no entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.594069Binding0.3430.8730.750-4.124Likely Benign0.464AmbiguousLikely Benign0.096Likely Benign-1.31Neutral0.917Possibly Damaging0.666Possibly Damaging2.56Benign0.00Affected0.09650.1559-2-2-7.729.98
c.3307C>A
R1103S
2D
AIThe SynGAP1 missense variant R1103S is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and FATHMM, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign, and Foldetta results are unavailable. Overall, the majority of evidence (six benign versus two pathogenic predictions) indicates that R1103S is most likely benign, and this conclusion does not contradict any ClinVar annotation because no ClinVar claim exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.945666Disordered0.957363Binding0.3280.8620.875-3.611Likely Benign0.464AmbiguousLikely Benign0.111Likely Benign-1.94Neutral0.511Possibly Damaging0.187Benign2.48Pathogenic0.28Tolerated0.30250.42240-13.7-69.11
c.3598G>C
E1200Q
2D
AIThe SynGAP1 missense variant E1200Q is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available, so these do not influence the overall interpretation. High‑accuracy assessments—AlphaMissense‑Optimized (benign) and SGM‑Consensus (likely benign)—support a benign classification. Consequently, the variant is most likely benign, and this assessment does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.545602Disordered0.458056Uncertain0.8890.5960.250-4.411Likely Benign0.464AmbiguousLikely Benign0.183Likely Benign0.14Neutral0.994Probably Damaging0.946Probably Damaging2.84Benign0.30Tolerated0.07670.4012220.0-0.98
c.59C>T
P20L
2D
AIThe SynGAP1 missense variant P20L (ClinVar ID 1185912.0) is listed as “Uncertain” in ClinVar and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as likely benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar status, which remains uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.529623Disordered0.442804Uncertain0.4480.8990.500Uncertain 3-3.289Likely Benign0.464AmbiguousLikely Benign0.100Likely Benign-0.44Neutral0.909Possibly Damaging0.713Possibly Damaging4.27Benign0.00Affected4.3210.24790.7258-3-35.416.04
c.2366C>A
P789Q
2D
AIThe SynGAP1 P789Q missense change is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) favors pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a pathogenic impact, and this conclusion does not contradict the ClinVar status, which currently has no classification for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.963420Disordered0.541575Binding0.3980.9030.750-5.191Likely Benign0.465AmbiguousLikely Benign0.235Likely Benign-4.53Deleterious1.000Probably Damaging0.999Probably Damaging2.03Pathogenic0.00Affected0.12840.32150-1-1.931.01
c.2371A>G
K791E
2D
AIThe SynGAP1 missense variant K791E is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools uniformly favor a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also reports a likely benign outcome. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) indicates likely benign; Foldetta results are unavailable. Taken together, the preponderance of evidence supports a benign impact for K791E, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.966441Disordered0.478670Uncertain0.3560.8960.875-3.823Likely Benign0.465AmbiguousLikely Benign0.053Likely Benign-0.58Neutral0.451Benign0.193Benign4.22Benign0.65Tolerated0.48290.0876010.40.94
c.359G>A
G120D
2D
AIThe SynGAP1 missense variant G120D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the evidence overwhelmingly supports a benign classification, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.707965Disordered0.659993Binding0.3590.8870.750-3.483Likely Benign0.465AmbiguousLikely Benign0.037Likely Benign-0.57Neutral0.165Benign0.034Benign4.25Benign0.21Tolerated0.18470.20241-1-3.158.04
c.515G>A
R172Q
2D
AISynGAP1 missense variant R172Q is listed in ClinVar with an uncertain significance and is present in gnomAD (ID 6‑33435157‑G‑A). Functional prediction tools that agree on benign impact include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Optimized. Those that predict pathogenicity are polyPhen‑2 HumDiv and SIFT, while ESM1b and AlphaMissense‑Default are inconclusive. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also returns benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of evidence points to a benign effect, which does not contradict the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.525368Disordered0.491688Uncertain0.4110.6510.375Uncertain 16-33435157-G-A31.86e-6-7.245In-Between0.465AmbiguousLikely Benign0.135Likely Benign-1.72Neutral0.804Possibly Damaging0.091Benign4.04Benign0.04Affected3.6150.22540.2532111.0-28.06
c.1219C>G
Q407E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q407E is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FATHMM, and AlphaMissense‑Optimized, whereas premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b all predict a pathogenic outcome. AlphaMissense‑Default, FoldX, Rosetta, and Foldetta are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the majority of tools and the SGM Consensus support a pathogenic classification, while a minority predict benign. No ClinVar entry exists to contradict these predictions. Thus, the variant is most likely pathogenic based on the available computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.109221Structured0.382522Uncertain0.9160.2710.000-12.631Likely Pathogenic0.466AmbiguousLikely Benign0.50Ambiguous0.11.68Ambiguous1.09Ambiguous1.30Destabilizing0.243Likely Benign-2.66Deleterious0.989Probably Damaging0.930Probably Damaging3.96Benign0.03Affected0.11990.2000220.00.98
c.1553A>T
Y518F
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 Y518F missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, SIFT, FATHMM, AlphaMissense‑Optimized, and Foldetta. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Two tools are uncertain: Rosetta and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic. Overall, the majority of individual predictors (seven benign vs. four pathogenic) support a benign classification, and this does not contradict the ClinVar status, which has no entry for this variant. Thus, based on the available predictions, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.139895Structured0.126970Uncertain0.8970.3210.000-10.617Likely Pathogenic0.466AmbiguousLikely Benign0.34Likely Benign0.1-0.61Ambiguous-0.14Likely Benign0.41Likely Benign0.318Likely Benign-3.68Deleterious0.999Probably Damaging0.996Probably Damaging3.50Benign0.22Tolerated0.21070.2230734.1-16.00
c.2482A>C
T828P
2D
AIThe SynGAP1 missense variant T828P is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include REVEL, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain. The SGM Consensus, which aggregates the majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, resolves to benign (2 benign vs. 1 pathogenic). High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus as benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta) is unavailable. Overall, the preponderance of evidence points to a benign impact for T828P, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.604312Disordered0.631236Binding0.3210.8790.500-3.902Likely Benign0.466AmbiguousLikely Benign0.280Likely Benign-2.53Deleterious1.000Probably Damaging0.998Probably Damaging2.61Benign0.12Tolerated0.18980.44240-1-0.9-3.99
c.3004C>A
H1002N
2D
AIThe SynGAP1 missense variant H1002N is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy methods reinforce the benign interpretation: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign, with no Foldetta data to contradict. Overall, the preponderance of evidence points to a benign effect for H1002N, and this assessment does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.953758Binding0.2850.9000.500-5.622Likely Benign0.466AmbiguousLikely Benign0.076Likely Benign-1.41Neutral0.801Possibly Damaging0.596Possibly Damaging2.76Benign1.00Tolerated0.20840.305721-0.3-23.04
c.3983G>C
R1328P
2D
AIThe SynGAP1 missense variant R1328P (ClinVar ID 1258976.0) is classified as Benign in ClinVar and is observed in gnomAD (6‑33451857‑G‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and Foldetta results are unavailable. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also indicates a likely benign outcome; no Foldetta stability data are reported. Overall, the majority of evidence points to a benign impact, aligning with the ClinVar designation and not contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.911775Binding0.3600.7620.875Benign 16-33451857-G-C-1.220Likely Benign0.466AmbiguousLikely Benign0.060Likely Benign-2.01Neutral0.927Possibly Damaging0.452Possibly Damaging4.06Benign0.01Affected3.7750.22050.33610-22.9-59.07
c.1431G>A
M477I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M477I is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while FoldX, Foldetta, and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta as uncertain. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation and gnomAD presence, indicating no contradiction with existing database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.268042Structured0.408680Uncertain0.7610.2500.000-2.662Likely Benign0.467AmbiguousLikely Benign0.72Ambiguous0.10.36Likely Benign0.54Ambiguous0.45Likely Benign0.291Likely Benign-1.57Neutral0.000Benign0.001Benign-1.21Pathogenic0.09Tolerated0.13680.3176212.6-18.03
c.1431G>C
M477I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M477I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and AlphaMissense‑Optimized all predict benign. Only FATHMM predicts pathogenic, while FoldX, Foldetta, and AlphaMissense‑Default are uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is benign, and Foldetta remains uncertain. Overall, the majority of evidence supports a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.268042Structured0.408680Uncertain0.7610.2500.000-2.662Likely Benign0.467AmbiguousLikely Benign0.72Ambiguous0.10.36Likely Benign0.54Ambiguous0.45Likely Benign0.290Likely Benign-1.57Neutral0.000Benign0.001Benign-1.21Pathogenic0.09Tolerated0.13680.3176212.6-18.03
c.1431G>T
M477I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M477I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and AlphaMissense‑Optimized all predict benign. Only FATHMM predicts pathogenic, while FoldX, Foldetta, and AlphaMissense‑Default are uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is benign, and Foldetta remains uncertain. Overall, the majority of evidence supports a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no classification for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.268042Structured0.408680Uncertain0.7610.2500.000-2.662Likely Benign0.467AmbiguousLikely Benign0.72Ambiguous0.10.36Likely Benign0.54Ambiguous0.45Likely Benign0.291Likely Benign-1.57Neutral0.000Benign0.001Benign-1.21Pathogenic0.09Tolerated0.13680.3176212.6-18.03
c.1465C>G
L489V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L489V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a deleterious effect: pathogenic calls come from SGM‑Consensus, REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM, while only AlphaMissense‑Optimized predicts a benign outcome. Uncertain results are reported by Rosetta, Foldetta, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as inconclusive. Overall, the preponderance of evidence points to a pathogenic effect for L489V. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing database record.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.191378Structured0.326126Uncertain0.9490.2340.125-9.345Likely Pathogenic0.467AmbiguousLikely Benign2.09Destabilizing0.01.70Ambiguous1.90Ambiguous1.25Destabilizing0.586Likely Pathogenic-2.55Deleterious0.998Probably Damaging0.992Probably Damaging-1.34Pathogenic0.01Affected0.16650.4108210.4-14.03
c.232C>T
R78C
2D
AIThe SynGAP1 missense variant R78C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for R78C, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.505461Disordered0.448183Uncertain0.3040.8660.500-6.079Likely Benign0.467AmbiguousLikely Benign0.114Likely Benign-2.13Neutral0.991Probably Damaging0.194Benign3.80Benign0.00Affected0.32550.2804-4-37.0-53.05
c.3095T>A
L1032Q
2D
AIThe SynGAP1 missense variant L1032Q is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the aggregate evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is assigned).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.865454Disordered0.995318Binding0.3650.7350.500-2.992Likely Benign0.467AmbiguousLikely Benign0.134Likely Benign-0.78Neutral0.995Probably Damaging0.892Possibly Damaging2.66Benign0.03Affected0.12170.1677-2-2-7.314.97
c.3206A>G
Q1069R
2D
AIThe SynGAP1 missense variant Q1069R is not reported in ClinVar (ClinVar ID = None) and has no entries in gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable. Overall, the preponderance of evidence points to the variant being most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.981477Binding0.3330.9060.875-3.257Likely Benign0.467AmbiguousLikely Benign0.094Likely Benign-1.17Neutral0.666Possibly Damaging0.355Benign2.73Benign0.21Tolerated0.15570.311411-1.028.06
c.340A>C
K114Q
2D
AIThe SynGAP1 missense variant K114Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict benign. Pathogenic predictions come from polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, SGM‑Consensus is Likely Benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and there is no ClinVar annotation to contradict this assessment.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.649749Binding0.3810.8790.750-3.221Likely Benign0.467AmbiguousLikely Benign0.058Likely Benign-1.33Neutral0.608Possibly Damaging0.108Benign3.98Benign0.00Affected0.54760.1530Weaken110.4-0.04
c.3870G>C
R1290S
2D
AIThe SynGAP1 missense variant R1290S is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM, while pathogenic predictions come from PROVEAN and SIFT. The high‑accuracy consensus (SGM Consensus) – derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN – favors a benign outcome (2 benign vs. 1 pathogenic, with one uncertain). AlphaMissense‑Optimized also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence indicates a benign effect, and this assessment does not contradict any ClinVar annotation, as none exists for R1290S.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.784345Disordered0.844138Binding0.5670.7950.625-3.507Likely Benign0.467AmbiguousLikely Benign0.120Likely Benign-2.99Deleterious0.451Benign0.209Benign2.65Benign0.01Affected0.26550.27330-13.7-69.11
c.3870G>T
R1290S
2D
AIThe SynGAP1 missense variant R1290S is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and SIFT. AlphaMissense‑Default is uncertain. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is benign (2 benign vs. 1 pathogenic, 1 uncertain). High‑accuracy predictions show AlphaMissense‑Optimized as benign and the SGM Consensus as benign; Foldetta results are unavailable. Overall, the consensus of available evidence indicates that R1290S is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.784345Disordered0.844138Binding0.5670.7950.625-3.507Likely Benign0.467AmbiguousLikely Benign0.120Likely Benign-2.99Deleterious0.451Benign0.209Benign2.65Benign0.01Affected0.26550.27330-13.7-69.11
c.1180A>C
K394Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 K394Q missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. Those that predict a pathogenic outcome are SIFT and Rosetta. The remaining tools—Foldetta, premPS, ESM1b, and AlphaMissense‑Default—return uncertain results and are treated as unavailable evidence. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, while the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also leans toward benign, with two benign votes and two uncertain votes. Foldetta’s stability prediction is uncertain and thus not considered. Overall, the majority of reliable predictions indicate a benign effect, and this conclusion does not contradict any existing ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.505461Disordered0.399336Uncertain0.3870.6340.625-7.261In-Between0.468AmbiguousLikely Benign0.15Likely Benign0.02.00Destabilizing1.08Ambiguous0.64Ambiguous0.330Likely Benign-2.46Neutral0.001Benign0.009Benign4.61Benign0.01Affected0.53650.2106Weaken110.4-0.04
c.1520A>C
K507T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 K507T missense variant has no ClinVar record and is not reported in gnomAD. Prediction tools that agree on a benign effect include SIFT, Rosetta, and AlphaMissense‑Optimized. Those that predict a pathogenic impact are SGM‑Consensus, REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, SGM‑Consensus (a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifying it as likely pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) yielding an uncertain result. Overall, the majority of available predictions lean toward pathogenicity, and this conclusion does not contradict the absence of a ClinVar classification. **The variant is most likely pathogenic based on the current predictive evidence.**

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.019401Structured0.262601Uncertain0.8850.2220.000-10.244Likely Pathogenic0.468AmbiguousLikely Benign0.82Ambiguous0.10.31Likely Benign0.57Ambiguous0.78Ambiguous0.724Likely Pathogenic-2.86Deleterious1.000Probably Damaging1.000Probably Damaging-1.55Pathogenic0.12Tolerated0.15010.24510-13.2-27.07
c.182A>G
E61G
2D
AIThe SynGAP1 missense variant E61G is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus methods reinforce the benign assessment: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign,” and the protein‑folding stability tool Foldetta is not available for this variant. Overall, the majority of evidence points to a benign effect. There is no ClinVar entry to contradict this conclusion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.352862Structured0.477329Uncertain0.5180.6990.125-5.574Likely Benign0.469AmbiguousLikely Benign0.072Likely Benign-1.68Neutral0.659Possibly Damaging0.775Possibly Damaging4.08Benign0.00Affected0.35930.49650-23.1-72.06
c.2696T>A
I899N
2D
AIThe SynGAP1 missense variant I899N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions come from polyPhen‑2 HumDiv and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, SGM‑Consensus is likely benign, and Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign effect for I899N, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.443727Uncertain0.2920.9280.375-3.328Likely Benign0.469AmbiguousLikely Benign0.058Likely Benign-0.68Neutral0.611Possibly Damaging0.140Benign2.76Benign0.00Affected0.09330.0470-2-3-8.00.94
c.1993T>A
Y665N
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 Y665N variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, premPS, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Four tools (FoldX, Rosetta, Foldetta, AlphaMissense‑Default) give uncertain results and are treated as unavailable evidence. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the majority of conventional predictors lean toward a benign impact, and this assessment does not contradict ClinVar status (none). Thus, the variant is most likely benign based on the prevailing predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.098513Structured0.086641Uncertain0.9220.3610.000-11.189Likely Pathogenic0.470AmbiguousLikely Benign1.11Ambiguous0.11.43Ambiguous1.27Ambiguous0.50Likely Benign0.219Likely Benign-3.03Deleterious1.000Probably Damaging0.996Probably Damaging3.50Benign0.88Tolerated0.19290.0573-2-2-2.2-49.07
c.202C>G
L68V
2D
AIThe SynGAP1 missense variant L68V has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized independently predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.470567Uncertain0.4050.7680.250-4.079Likely Benign0.470AmbiguousLikely Benign0.028Likely Benign-0.43Neutral0.458Possibly Damaging0.364Benign4.13Benign0.00Affected0.10770.2817210.4-14.03
c.2798A>T
H933L
2D
AIThe SynGAP1 H933L missense variant is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) predicts pathogenic. Foldetta results are unavailable. Overall, the majority of evidence points to a pathogenic impact. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.666105Disordered0.987531Binding0.3050.8620.625-0.858Likely Benign0.470AmbiguousLikely Benign0.388Likely Benign-6.26Deleterious0.999Probably Damaging0.996Probably Damaging2.38Pathogenic0.02Affected0.10030.5749-2-37.0-23.98
c.805A>C
I269L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 I269L missense variant is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in silico predictors shows a predominance of benign calls: REVEL, FoldX, Rosetta, premPS, PROVEAN, SIFT, and AlphaMissense‑Optimized all predict benign. Pathogenicity is suggested by polyPhen‑2 (HumDiv and HumVar) and FATHMM, while ESM1b and AlphaMissense‑Default remain uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, Foldetta predicts benign stability, and the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to an equal split between benign and pathogenic signals. Overall, the balance of evidence favors a benign effect for I269L, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.216401Structured0.343787Uncertain0.9370.2440.125-7.588In-Between0.470AmbiguousLikely Benign0.00Likely Benign0.00.19Likely Benign0.10Likely Benign0.47Likely Benign0.348Likely Benign-1.47Neutral0.981Probably Damaging0.970Probably Damaging1.88Pathogenic0.28Tolerated0.06620.281722-0.70.00
c.805A>T
I269L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I269L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two consensus groups: eight tools (REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, SIFT, AlphaMissense‑Optimized) predict a benign effect, while three tools (polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM) predict pathogenicity. Two tools (ESM1b, AlphaMissense‑Default) return uncertain results. High‑accuracy assessments further clarify the picture: AlphaMissense‑Optimized classifies the variant as benign; Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, also predicts a benign impact. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields no clear majority and is therefore unavailable as evidence. Overall, the preponderance of evidence supports a benign classification, which is consistent with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.216401Structured0.343787Uncertain0.9370.2440.125-7.588In-Between0.470AmbiguousLikely Benign0.00Likely Benign0.00.19Likely Benign0.10Likely Benign0.47Likely Benign0.348Likely Benign-1.47Neutral0.981Probably Damaging0.970Probably Damaging1.88Pathogenic0.28Tolerated0.06620.281722-0.70.00
c.166C>G
L56V
2D
AIThe SynGAP1 missense variant L56V is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also leans benign (2 benign vs 1 pathogenic, 1 uncertain). Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for the L56V variant, and this conclusion does not contradict any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.342579Structured0.476218Uncertain0.4950.6570.000-8.104Likely Pathogenic0.471AmbiguousLikely Benign0.123Likely Benign-0.99Neutral0.458Possibly Damaging0.745Possibly Damaging3.90Benign0.00Affected0.16350.3655210.4-14.03
c.2171C>T
A724V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 A724V missense variant is not reported in ClinVar and has no entries in gnomAD. Functional prediction tools show a split assessment: benign predictions come from REVEL, FoldX, Rosetta, Foldetta, premPS, and AlphaMissense‑Optimized, whereas pathogenic predictions are reported by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as likely pathogenic. High‑accuracy assessments further clarify the picture: AlphaMissense‑Optimized predicts benign, SGM Consensus predicts pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts benign. With no ClinVar annotation, there is no contradiction between the predictions and existing clinical data. Overall, the evidence is mixed, but the majority of high‑confidence tools lean toward a benign effect, suggesting the variant is most likely benign rather than pathogenic.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.476583Structured0.458050Uncertain0.9230.4830.250-9.000Likely Pathogenic0.471AmbiguousLikely Benign0.42Likely Benign0.10.35Likely Benign0.39Likely Benign0.24Likely Benign0.241Likely Benign-3.28Deleterious0.999Probably Damaging0.988Probably Damaging2.07Pathogenic0.01Affected0.08720.5620002.428.05
c.2707G>T
G903C
2D
AIThe SynGAP1 missense variant G903C is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. AlphaMissense‑Default is uncertain and does not influence the consensus. High‑accuracy assessments show AlphaMissense‑Optimized predicts a benign outcome, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) predicts pathogenic. Foldetta, which would provide a protein‑folding stability estimate, is unavailable for this variant. Overall, the majority of evidence (five pathogenic versus three benign predictions) points to a pathogenic impact. This conclusion is not contradicted by ClinVar status, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.680603Disordered0.549818Binding0.2910.9170.375-6.593Likely Benign0.471AmbiguousLikely Benign0.151Likely Benign-3.28Deleterious1.000Probably Damaging0.990Probably Damaging2.32Pathogenic0.02Affected0.11580.4420-3-32.946.09
c.2966C>A
S989Y
2D
AIThe SynGAP1 missense variant S989Y is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. High‑accuracy predictions therefore indicate a benign outcome: AlphaMissense‑Optimized is benign, the SGM Consensus is benign, and Foldetta data are unavailable. Consequently, the variant is most likely benign based on the current computational evidence, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.795062Disordered0.908835Binding0.2960.9110.750-4.774Likely Benign0.471AmbiguousLikely Benign0.103Likely Benign-3.32Deleterious0.986Probably Damaging0.876Possibly Damaging2.60Benign0.00Affected0.06110.4815-3-2-0.576.10
c.3574C>G
L1192V
2D
AIThe SynGAP1 missense variant L1192V is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). In contrast, polyPhen‑2 (both HumDiv and HumVar models) predict a pathogenic impact. The high‑accuracy AlphaMissense‑Optimized score is benign, and the SGM‑Consensus also indicates a likely benign outcome; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this is consistent with the ClinVar “Uncertain” classification rather than contradicting it. Thus, based on current predictions, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.575842Disordered0.441757Uncertain0.7620.6090.625Uncertain 1-4.132Likely Benign0.471AmbiguousLikely Benign0.041Likely Benign-0.89Neutral0.779Possibly Damaging0.527Possibly Damaging2.69Benign0.16Tolerated0.14410.2289210.4-14.03
c.3685C>A
Q1229K
2D
AISynGAP1 missense variant Q1229K is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign calls from REVEL, PROVEAN, SIFT, and AlphaMissense‑Optimized; pathogenic calls from polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. AlphaMissense‑Default remains uncertain. High‑accuracy assessment shows AlphaMissense‑Optimized predicts benign, while the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic; Foldetta stability analysis is unavailable. Overall, the evidence is split, with an equal number of benign and pathogenic predictions, and the high‑accuracy tools provide one benign and one pathogenic call. Thus, the variant is most likely pathogenic based on the preponderance of pathogenic predictions, and this assessment does not contradict the ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.490133Structured0.466729Uncertain0.8650.5440.375-9.803Likely Pathogenic0.471AmbiguousLikely Benign0.159Likely Benign-2.36Neutral0.985Probably Damaging0.981Probably Damaging1.82Pathogenic0.22Tolerated0.13470.288311-0.40.04
c.2363C>G
S788C
2D
AIThe SynGAP1 missense variant S788C is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect are REVEL and AlphaMissense‑Optimized, while five tools (PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM) predict a pathogenic outcome. Two tools (ESM1b and AlphaMissense‑Default) return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, whereas the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—classifies the variant as pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a pathogenic effect, and this conclusion does not contradict any ClinVar status because the variant has not yet been classified in that database.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.956248Disordered0.573557Binding0.3490.8950.750-7.935In-Between0.472AmbiguousLikely Benign0.269Likely Benign-3.90Deleterious0.999Probably Damaging0.997Probably Damaging1.50Pathogenic0.00Affected0.13930.60730-13.316.06
c.2764C>G
R922G
2D
AIThe SynGAP1 missense variant R922G is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree that the change is benign: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict a benign effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic effect. AlphaMissense‑Default remains uncertain, and no Foldetta stability assessment is available. High‑accuracy tools reinforce the benign prediction: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta data are missing. Overall, the preponderance of evidence points to a benign impact for R922G, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.549308Disordered0.955308Binding0.2770.8450.375-2.490Likely Benign0.472AmbiguousLikely Benign0.104Likely Benign-1.48Neutral0.967Probably Damaging0.626Possibly Damaging2.55Benign0.10Tolerated0.34730.3768-3-24.1-99.14
c.3989A>G
Q1330R
2D
AIThe SynGAP1 missense variant Q1330R is listed in gnomAD (ID 6‑33451863‑A‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.931969Binding0.3690.7520.8756-33451863-A-G-3.601Likely Benign0.472AmbiguousLikely Benign0.031Likely Benign-1.65Neutral0.898Possibly Damaging0.341Benign3.95Benign0.03Affected3.7750.13490.233311-1.028.06
c.278G>C
R93P
2D
AIThe SynGAP1 missense variant R93P is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus indicates Likely Benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.549151Binding0.2900.8740.625-3.164Likely Benign0.473AmbiguousLikely Benign0.121Likely Benign-0.32Neutral0.361Benign0.038Benign3.99Benign0.00Affected0.22000.48440-22.9-59.07
c.3355G>A
G1119R
2D
AIThe SynGAP1 missense variant G1119R is listed in ClinVar as benign and is present in gnomAD (ID 6‑33443907‑G‑A). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and ESM1b predict a pathogenic impact. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, aligning with the ClinVar classification; there is no contradiction between the predictions and the reported ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.827927Disordered0.818538Binding0.3390.9280.875Benign 16-33443907-G-A644.23e-5-8.489Likely Pathogenic0.473AmbiguousLikely Benign0.303Likely Benign0.10Neutral0.969Probably Damaging0.462Possibly Damaging4.03Benign0.10Tolerated4.3220.11120.4733-3-2-4.199.14
c.3355G>C
G1119R
2D
AIThe SynGAP1 missense variant G1119R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. AlphaMissense‑Default is uncertain. High‑accuracy assessment shows AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also resolves to benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence points to a benign effect. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.827927Disordered0.818538Binding0.3390.9280.875-8.489Likely Pathogenic0.473AmbiguousLikely Benign0.289Likely Benign0.10Neutral0.969Probably Damaging0.462Possibly Damaging4.03Benign0.10Tolerated4.3220.11120.4733-3-2-4.199.14
c.3826G>A
D1276N
2D
AIThe SynGAP1 missense variant D1276N is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) predicts pathogenic. Foldetta results are unavailable. Overall, more tools (five) predict pathogenicity than benign (three), and the high‑accuracy consensus also leans pathogenic. Therefore, the variant is most likely pathogenic based on current predictions, and this assessment does not contradict any ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.666105Disordered0.802156Binding0.6360.7050.6253.371Likely Benign0.473AmbiguousLikely Benign0.242Likely Benign-3.68Deleterious0.899Possibly Damaging0.581Possibly Damaging1.22Pathogenic0.00Affected0.08830.5213210.0-0.98
c.1828C>G
L610V
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant L610V is reported in gnomAD (ID 6‑33440880‑C‑G) but has no ClinVar entry. Functional prediction tools largely agree on a deleterious effect: pathogenic calls are made by REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM, while only AlphaMissense‑Optimized predicts a benign outcome. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Pathogenic. High‑accuracy assessments further support this view: AlphaMissense‑Optimized indicates benign, whereas the SGM Consensus remains pathogenic and Foldetta (combining FoldX‑MD and Rosetta) is inconclusive. With the overwhelming majority of tools predicting pathogenicity and no ClinVar evidence to contradict this, the variant is most likely pathogenic.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.271506Structured0.209504Uncertain0.8880.2530.0006-33440880-C-G31.86e-6-11.304Likely Pathogenic0.474AmbiguousLikely Benign2.24Destabilizing0.30.76Ambiguous1.50Ambiguous1.21Destabilizing0.740Likely Pathogenic-2.86Deleterious0.985Probably Damaging0.992Probably Damaging-1.46Pathogenic0.01Affected3.37350.15150.3039120.4-14.03
c.2431C>T
P811S
2D
AIThe SynGAP1 missense variant P811S is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority of high‑accuracy predictors (AlphaMissense‑Optimized and the SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also support a benign classification. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact, and AlphaMissense‑Default remains uncertain. No Foldetta stability assessment is available, so it does not contribute to the evidence. Overall, the preponderance of evidence points to a benign effect for P811S, and this conclusion is not contradicted by any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.411940Structured0.847064Binding0.3820.9100.250-4.733Likely Benign0.474AmbiguousLikely Benign0.128Likely Benign-1.28Neutral0.982Probably Damaging0.824Possibly Damaging2.79Benign0.78Tolerated0.36560.59601-10.8-10.04
c.2536T>A
L846I
2D
AIThe SynGAP1 missense variant L846I is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and FATHMM. Two tools, ESM1b and AlphaMissense‑Default, return uncertain results. For high‑accuracy assessment, AlphaMissense‑Optimized classifies the variant as benign. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive because the votes are split (one pathogenic, one benign, two uncertain). Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, has no available output for this variant. Overall, the balance of evidence from the majority of prediction tools suggests the variant is most likely pathogenic, and this assessment does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.653063Disordered0.589606Binding0.3490.8250.500-7.882In-Between0.474AmbiguousLikely Benign0.151Likely Benign-1.38Neutral0.997Probably Damaging0.992Probably Damaging2.18Pathogenic0.00Affected0.09730.3475220.70.00
c.1440G>C
E480D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 E480D missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, and ESM1b, whereas polyPhen‑2 (HumDiv and HumVar) and FATHMM predict a pathogenic impact. The remaining tools—FoldX, Rosetta, premPS, AlphaMissense‑Default, and Foldetta—return uncertain or inconclusive results and are treated as unavailable evidence. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign majority, and Foldetta remains uncertain. Overall, the balance of evidence favors a benign classification for E480D, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.216401Structured0.426867Uncertain0.7980.2500.000-3.001Likely Benign0.475AmbiguousLikely Benign0.62Ambiguous0.21.39Ambiguous1.01Ambiguous0.61Ambiguous0.405Likely Benign-0.77Neutral0.989Probably Damaging0.979Probably Damaging-1.27Pathogenic0.28Tolerated0.15260.4130320.0-14.03
c.1440G>T
E480D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 E480D missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, and ESM1b, while polyPhen‑2 (HumDiv and HumVar) and FATHMM predict a pathogenic outcome. The remaining tools—FoldX, Rosetta, premPS, AlphaMissense‑Default, and Foldetta—return uncertain or inconclusive results and are treated as unavailable evidence. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) leaning toward benign, and Foldetta providing no definitive stability change. Overall, the balance of evidence favors a benign interpretation, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.216401Structured0.426867Uncertain0.7980.2500.000-3.001Likely Benign0.475AmbiguousLikely Benign0.62Ambiguous0.21.39Ambiguous1.01Ambiguous0.61Ambiguous0.405Likely Benign-0.77Neutral0.989Probably Damaging0.979Probably Damaging-1.27Pathogenic0.28Tolerated0.15260.4130320.0-14.03
c.2954G>C
S985T
2D
AIThe SynGAP1 missense variant S985T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for S985T, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.720929Disordered0.941547Binding0.3020.8960.750-5.658Likely Benign0.475AmbiguousLikely Benign0.153Likely Benign-1.62Neutral0.979Probably Damaging0.982Probably Damaging2.54Benign0.00Affected0.18890.5844110.114.03
c.310C>T
R104C
2D
AIThe SynGAP1 missense variant R104C has no ClinVar entry and is present in gnomAD (ID 6‑33432175‑C‑T). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; the Foldetta protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.678998Binding0.3390.8690.6256-33432175-C-T21.24e-6-5.716Likely Benign0.475AmbiguousLikely Benign0.109Likely Benign-1.41Neutral0.993Probably Damaging0.446Benign3.99Benign0.00Affected4.3210.29540.3292-3-47.0-53.0510.1016/j.ajhg.2020.11.011
c.3317A>G
Q1106R
2D
AIThe SynGAP1 missense variant Q1106R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. AlphaMissense‑Default is uncertain, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because it contains two benign, one pathogenic, and one uncertain call. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of high‑confidence predictors (four benign vs. three pathogenic) lean toward a benign interpretation, and this assessment does not contradict the lack of ClinVar annotation. Thus, the variant is most likely benign based on current computational predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.885302Disordered0.952043Binding0.3820.8700.875-4.211Likely Benign0.475AmbiguousLikely Benign0.133Likely Benign-2.20Neutral0.985Probably Damaging0.973Probably Damaging1.80Pathogenic0.09Tolerated0.14120.285011-1.028.06
c.1883A>G
K628R
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant K628R is reported in gnomAD (variant ID 6‑33440935‑A‑G) but has no ClinVar entry. Functional prediction tools show a split assessment: benign calls come from FoldX, Rosetta, Foldetta, and AlphaMissense‑Optimized, whereas pathogenic calls are made by REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. Two tools remain inconclusive (premPS and AlphaMissense‑Default). The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a likely pathogenic verdict, while the high‑accuracy AlphaMissense‑Optimized predicts benign. Foldetta, a protein‑folding stability method that combines FoldX‑MD and Rosetta outputs, also predicts benign. Overall, the majority of evidence leans toward pathogenicity, and this conclusion does not conflict with ClinVar status, which is currently absent.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.088832Structured0.035486Uncertain0.9570.2290.0006-33440935-A-G16.20e-7-11.324Likely Pathogenic0.476AmbiguousLikely Benign0.22Likely Benign0.1-0.11Likely Benign0.06Likely Benign0.94Ambiguous0.592Likely Pathogenic-2.99Deleterious0.996Probably Damaging0.990Probably Damaging2.49Pathogenic0.00Affected3.37340.38730.087323-0.628.01
c.1951G>C
E651Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant E651Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM—all classifying the change as benign. No tool predicts a pathogenic outcome. The high‑accuracy assessments are consistent: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign effect; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also reports a benign result. Consequently, the variant is most likely benign based on the available predictions, and this assessment does not contradict any ClinVar status (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.088832Structured0.365409Uncertain0.9550.3400.000-6.308Likely Benign0.476AmbiguousLikely Benign0.13Likely Benign0.10.15Likely Benign0.14Likely Benign-0.13Likely Benign0.158Likely Benign-1.23Neutral0.244Benign0.075Benign3.34Benign0.58Tolerated0.14380.5893220.0-0.98
c.215G>T
R72L
2D
AIThe SynGAP1 missense variant R72L is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign. Pathogenicity is suggested only by polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for R72L, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.497853Structured0.455349Uncertain0.3550.8190.375-3.102Likely Benign0.476AmbiguousLikely Benign0.108Likely Benign-1.49Neutral0.686Possibly Damaging0.250Benign4.12Benign0.00Affected0.21040.4352-3-28.3-43.03
c.219G>C
R73S
2D
AIThe SynGAP1 missense variant R73S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, the SGM‑Consensus likewise indicates Likely Benign, and Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.501700Disordered0.453164Uncertain0.3320.8260.375-2.919Likely Benign0.476AmbiguousLikely Benign0.107Likely Benign-0.89Neutral0.028Benign0.004Benign4.07Benign0.00Affected0.33360.40260-13.7-69.11
c.219G>T
R73S
2D
AIThe SynGAP1 missense variant R73S is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a Likely Benign classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, the SGM‑Consensus (majority vote) also indicates Likely Benign, and Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.501700Disordered0.453164Uncertain0.3320.8260.375-2.919Likely Benign0.476AmbiguousLikely Benign0.107Likely Benign-0.89Neutral0.028Benign0.004Benign4.07Benign0.00Affected0.33360.40260-13.7-69.11
c.2405G>A
G802D
2D
AIThe SynGAP1 missense variant G802D is listed in ClinVar with an “Uncertain” status and is present in gnomAD (6‑33442957‑G‑A). Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM—all classifying the change as benign. No tool predicts a pathogenic outcome. The high‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign effect. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions points to a benign impact, which does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.894241Disordered0.681966Binding0.2940.8980.625Uncertain 16-33442957-G-A16.20e-7-5.083Likely Benign0.476AmbiguousLikely Benign0.153Likely Benign-0.38Neutral0.126Benign0.138Benign2.72Benign0.09Tolerated3.7750.19930.27421-1-3.158.04
c.3493T>G
S1165A
2D
AIThe SynGAP1 missense variant S1165A is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority of other predictors (polyPhen‑2 HumDiv and HumVar) suggest pathogenic. When predictions are grouped by agreement, the benign‑predicating tools outnumber the pathogenic ones, and the single uncertain call from AlphaMissense‑Default does not alter this balance. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized classifies the variant as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports it as Likely Benign. Foldetta data are unavailable. Overall, the computational evidence points to a benign effect, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.509769Disordered0.835017Binding0.3080.8070.375-3.308Likely Benign0.476AmbiguousLikely Benign0.106Likely Benign-1.11Neutral0.979Probably Damaging0.982Probably Damaging2.61Benign0.60Tolerated0.53630.4236Weaken112.6-16.00
c.1300G>C
V434L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V434L is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, PROVEAN, SIFT, and FATHMM. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Two tools, Rosetta and AlphaMissense‑Default, give uncertain results. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign consensus; and Foldetta, a protein‑folding stability method, also predicts benign. No prediction or stability result is missing or inconclusive. Overall, the preponderance of evidence indicates that V434L is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.158265Structured0.342846Uncertain0.9540.3060.000-8.697Likely Pathogenic0.477AmbiguousLikely Benign-0.05Likely Benign0.01.02Ambiguous0.49Likely Benign0.20Likely Benign0.225Likely Benign-2.30Neutral0.947Possibly Damaging0.851Possibly Damaging3.64Benign0.27Tolerated0.08950.381321-0.414.03
c.308G>A
G103D
2D
AIThe SynGAP1 missense variant G103D is not reported in ClinVar and has no entry in gnomAD. Consensus from multiple in‑silico predictors shows a predominance of benign calls: REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict a benign effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT each predict a pathogenic impact. The AlphaMissense‑Default tool remains uncertain, and no Foldetta stability assessment is available. High‑accuracy tools specifically highlight benign predictions: AlphaMissense‑Optimized is benign, SGM‑Consensus is likely benign, and Foldetta data are missing. Overall, the balance of evidence points to a benign effect for G103D, and this assessment does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.687376Binding0.3810.8770.625-3.523Likely Benign0.477AmbiguousLikely Benign0.110Likely Benign-0.10Neutral0.949Possibly Damaging0.617Possibly Damaging4.26Benign0.00Affected0.22370.28961-1-3.158.04
c.3713A>G
Q1238R
2D
AIThe SynGAP1 missense variant Q1238R is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Consensus from standard predictors shows a split: benign calls come from REVEL, PROVEAN, and AlphaMissense‑Optimized, whereas pathogenic calls arise from polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessment gives AlphaMissense‑Optimized benign, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—leans pathogenic. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the balance of evidence favors a pathogenic interpretation, and this conclusion does not conflict with the ClinVar status, which currently contains no assertion for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.562014Disordered0.548882Binding0.8550.5450.250-10.216Likely Pathogenic0.477AmbiguousLikely Benign0.229Likely Benign-2.29Neutral0.994Probably Damaging0.988Probably Damaging2.40Pathogenic0.04Affected0.11650.201911-1.028.06
c.3745A>T
R1249W
2D
AIThe SynGAP1 missense variant R1249W is not reported in ClinVar and has no entries in gnomAD. Functional prediction tools show mixed results: benign predictions come from REVEL and AlphaMissense‑Optimized, whereas pathogenic predictions are returned by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Pathogenic. High‑accuracy assessments further support a pathogenic interpretation: AlphaMissense‑Optimized predicts benign, but the SGM‑Consensus (majority vote) is pathogenic, and no Foldetta stability data are available. Overall, the majority of evidence points toward a pathogenic effect, which is consistent with the SGM‑Consensus designation and contradicts the benign predictions from a minority of tools. Thus, the variant is most likely pathogenic, and this conclusion aligns with the lack of ClinVar annotation rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicCoiled-coil0.745909Disordered0.366265Uncertain0.8740.5560.875-9.841Likely Pathogenic0.477AmbiguousLikely Benign0.209Likely Benign-6.18Deleterious1.000Probably Damaging0.990Probably Damaging1.68Pathogenic0.00Affected0.12560.21792-33.630.03
c.3863A>C
K1288T
2D
AIThe SynGAP1 missense variant K1288T is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) predicts pathogenic. Foldetta results are unavailable. Overall, more tools (five) predict pathogenicity than benign (three), and the high‑accuracy consensus also leans pathogenic. Therefore, the variant is most likely pathogenic based on current predictions, and this assessment does not contradict any ClinVar status because the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.827927Disordered0.814714Binding0.5380.7840.625-2.616Likely Benign0.477AmbiguousLikely Benign0.227Likely Benign-4.84Deleterious0.991Probably Damaging0.982Probably Damaging2.09Pathogenic0.00Affected0.20660.26140-13.2-27.07
c.3990G>C
Q1330H
2D
AIThe SynGAP1 missense variant Q1330H is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools cluster into two consensus groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign effect. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, the SGM‑Consensus also reports it as likely benign, and Foldetta (which integrates FoldX‑MD and Rosetta stability calculations) has no available result for this residue. Based on the preponderance of benign predictions from multiple independent algorithms and the lack of pathogenic evidence, the variant is most likely benign. This conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.931969Binding0.3690.7520.875-3.557Likely Benign0.477AmbiguousLikely Benign0.066Likely Benign-1.91Neutral0.969Probably Damaging0.732Possibly Damaging3.91Benign0.02Affected0.11900.3996300.39.01
c.3990G>T
Q1330H
2D
AIThe SynGAP1 missense variant Q1330H is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools cluster into two consensus groups: benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign effect. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, the SGM‑Consensus also reports it as likely benign, and Foldetta (which integrates FoldX‑MD and Rosetta stability calculations) has no available result for this residue. Based on the preponderance of benign predictions from multiple independent algorithms and the lack of pathogenic evidence, the variant is most likely benign. This conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.943310Disordered0.931969Binding0.3690.7520.875-3.557Likely Benign0.477AmbiguousLikely Benign0.066Likely Benign-1.91Neutral0.969Probably Damaging0.732Possibly Damaging3.91Benign0.02Affected0.11900.3996300.39.01
c.1114G>T
G372W
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G372W has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include premPS, PROVEAN, polyPhen‑2 HumVar, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are REVEL, FoldX, polyPhen‑2 HumDiv, SIFT, ESM1b, and FATHMM. The remaining tools (Rosetta, Foldetta, AlphaMissense‑Default) give uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the majority of evidence points to a pathogenic impact, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.433034Structured0.430335Uncertain0.3220.7740.375-8.262Likely Pathogenic0.478AmbiguousLikely Benign2.28Destabilizing0.51.14Ambiguous1.71Ambiguous0.21Likely Benign0.649Likely Pathogenic-1.25Neutral0.657Possibly Damaging0.075Benign-0.74Pathogenic0.00Affected0.10570.4368-7-2-0.5129.16
c.1322T>G
V441G
2D
3DClick to see structure in 3D Viewer
AISynGAP1 variant V441G is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into three groups: benign predictions come from REVEL, FoldX, SIFT, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions arise from PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b; the remaining tools (Rosetta, Foldetta, premPS, AlphaMissense‑Default) give uncertain results. High‑accuracy assessments further refine the picture: AlphaMissense‑Optimized remains benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) favors pathogenic, and Foldetta is inconclusive. Taken together, the majority of evidence points to a benign effect, but the SGM Consensus and several individual pathogenic predictors introduce uncertainty. Therefore, the variant is most likely benign based on the overall prediction landscape, and this assessment does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.161087Structured0.259875Uncertain0.9180.2490.000-12.380Likely Pathogenic0.478AmbiguousLikely Benign0.18Likely Benign0.01.25Ambiguous0.72Ambiguous0.95Ambiguous0.273Likely Benign-5.88Deleterious0.841Possibly Damaging0.997Probably Damaging3.41Benign0.24Tolerated0.16640.1715-1-3-4.6-42.08
c.1408A>G
M470V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M470V is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Consensus from most in silico predictors indicates a pathogenic effect: SGM‑Consensus, REVEL, FoldX, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM all score it as deleterious. Only two tools—SIFT and AlphaMissense‑Optimized—classify it as benign, while Rosetta and AlphaMissense‑Default remain inconclusive. High‑accuracy assessments reinforce the pathogenic prediction: AlphaMissense‑Optimized reports a benign outcome, but the SGM‑Consensus (derived from a majority of pathogenic calls among AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) and Foldetta (combining pathogenic FoldX with uncertain Rosetta) both predict pathogenicity. Overall, the preponderance of evidence supports a likely pathogenic classification, which does not conflict with the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.298791Structured0.351497Uncertain0.9080.2720.000Uncertain 1-8.856Likely Pathogenic0.478AmbiguousLikely Benign2.73Destabilizing0.11.88Ambiguous2.31Destabilizing1.31Destabilizing0.770Likely Pathogenic-3.58Deleterious0.999Probably Damaging0.993Probably Damaging-1.20Pathogenic0.15Tolerated3.37340.27100.3256122.3-32.06
c.1480A>C
I494L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 I494L missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include FoldX, PROVEAN, SIFT, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. The remaining tools—Rosetta, Foldetta, premPS, and AlphaMissense‑Default—return uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the balance of evidence (five pathogenic versus four benign predictions, with several uncertain calls) leans toward a pathogenic interpretation. This conclusion does not contradict ClinVar status, as the variant has no ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.155435Structured0.353330Uncertain0.9410.1570.000-10.175Likely Pathogenic0.478AmbiguousLikely Benign0.28Likely Benign0.11.11Ambiguous0.70Ambiguous0.91Ambiguous0.513Likely Pathogenic-1.69Neutral0.645Possibly Damaging0.718Possibly Damaging-0.88Pathogenic0.11Tolerated0.08160.285122-0.70.00
c.1480A>T
I494L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 I494L variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include FoldX, PROVEAN, SIFT, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. The remaining tools—Rosetta, Foldetta, premPS, and AlphaMissense‑Default—return uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized predicting benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicting pathogenic, and Foldetta indicating uncertain stability change. Overall, the balance of evidence leans toward pathogenicity, with a majority of tools and the SGM Consensus supporting a deleterious effect. This conclusion does not contradict ClinVar status, as the variant is currently unreported there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.155435Structured0.353330Uncertain0.9410.1570.000-10.175Likely Pathogenic0.478AmbiguousLikely Benign0.28Likely Benign0.11.11Ambiguous0.70Ambiguous0.91Ambiguous0.513Likely Pathogenic-1.69Neutral0.645Possibly Damaging0.718Possibly Damaging-0.88Pathogenic0.11Tolerated0.08160.285122-0.70.00
c.2717T>C
L906P
2D
AIThe SynGAP1 missense variant L906P is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors a benign outcome. Foldetta, which would provide a protein‑folding stability estimate, is unavailable for this variant. Overall, the preponderance of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, which contains no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.604312Disordered0.644316Binding0.3150.9200.250-3.662Likely Benign0.478AmbiguousLikely Benign0.150Likely Benign0.08Neutral1.000Probably Damaging0.993Probably Damaging2.18Pathogenic0.10Tolerated0.34300.1458-3-3-5.4-16.04
c.3407A>G
Q1136R
2D
AIThe SynGAP1 missense variant Q1136R is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority‑vote SGM‑Consensus also reports a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The high‑accuracy AlphaMissense‑Optimized score is benign, and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also leans benign; Foldetta data are not available. Overall, the preponderance of evidence from both general and high‑accuracy predictors points to a benign classification, and this assessment does not conflict with the absence of a ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.903857Disordered0.775584Binding0.3210.8840.875-5.526Likely Benign0.478AmbiguousLikely Benign0.173Likely Benign-1.42Neutral0.801Possibly Damaging0.506Possibly Damaging6.28Benign0.09Tolerated0.15270.307311-1.028.06
c.389A>G
Q130R
2D
AIThe SynGAP1 missense variant Q130R is not reported in ClinVar and has no entry in gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions come from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, indicates a likely benign effect. High‑accuracy assessments further support this: AlphaMissense‑Optimized classifies the variant as benign, and the SGM‑Consensus also reports a likely benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from both general and high‑accuracy predictors points to a benign impact. This conclusion is consistent with the absence of a ClinVar assertion, so there is no contradiction with existing clinical database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.509769Disordered0.718853Binding0.3060.8850.375-4.043Likely Benign0.478AmbiguousLikely Benign0.166Likely Benign-0.32Neutral0.967Probably Damaging0.901Possibly Damaging4.21Benign0.05Affected0.16970.234311-1.028.06
c.194A>C
H65P
2D
AIThe SynGAP1 missense variant H65P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for H65P, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.411940Structured0.476188Uncertain0.4580.7580.125-1.732Likely Benign0.479AmbiguousLikely Benign0.103Likely Benign-1.47Neutral0.676Possibly Damaging0.227Benign4.16Benign0.00Affected0.19150.37010-21.6-40.02
c.1982A>G
Q661R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q661R is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, premPS, PROVEAN, SIFT, AlphaMissense‑Optimized, and polyPhen2_HumVar. Tools that predict a pathogenic effect are polyPhen2_HumDiv and ESM1b. FoldX, Rosetta, Foldetta, and AlphaMissense‑Default are inconclusive. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields a benign prediction, while Foldetta remains uncertain. Overall, the majority of available evidence points to a benign impact. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.048328Structured0.117089Uncertain0.9240.3090.000-10.386Likely Pathogenic0.479AmbiguousLikely Benign-1.12Ambiguous0.0-0.59Ambiguous-0.86Ambiguous-0.15Likely Benign0.281Likely Benign-2.06Neutral0.812Possibly Damaging0.251Benign3.52Benign0.18Tolerated0.15020.219611-1.028.06
c.1651C>A
L551M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L551M is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33438894‑C‑A). Prediction tools that classify the variant as benign include FoldX, Rosetta, Foldetta, PROVEAN, SIFT, and AlphaMissense‑Optimized, while those that predict pathogenicity are REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. Two tools report an uncertain outcome: premPS and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic. Overall, the majority of predictions lean toward a benign effect, and this does not contradict the ClinVar “Uncertain” classification. Thus, the variant is most likely benign based on the current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.009977Structured0.006653Uncertain0.9600.2540.000Uncertain 16-33438894-C-A74.34e-6-9.937Likely Pathogenic0.480AmbiguousLikely Benign-0.07Likely Benign0.10.13Likely Benign0.03Likely Benign0.71Ambiguous0.544Likely Pathogenic-0.56Neutral1.000Probably Damaging1.000Probably Damaging-1.48Pathogenic0.06Tolerated3.37350.08380.270142-1.918.03246.5-18.60.00.00.30.0XPotentially BenignL551 is located on an α-helix (res. Ala533-Val560). The iso-butyl side chain of Leu551 hydrophobically packs with nearby hydrophobic residues such as Cys547, Phe652, Leu633, and Ile630 in the inter-helix space. In the variant simulations, the thioether side chain of Met551 can maintain similar hydrophobic interactions as Leu551 in the WT, thus causing no negative effect on the protein structure during the simulations.
c.2089T>G
W697G
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 W697G missense change is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Functional prediction tools that agree on a benign effect include REVEL, SIFT, FATHMM, and AlphaMissense‑Optimized. In contrast, a majority of tools predict a pathogenic outcome: FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar). AlphaMissense‑Default and ESM1b are uncertain, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because it receives one benign, one pathogenic, and two uncertain calls. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as pathogenic, and the SGM Consensus remains unavailable. Overall, the preponderance of evidence from multiple independent pathogenicity predictors and the protein‑stability assessment by Foldetta indicates that W697G is most likely pathogenic. This conclusion is not contradicted by ClinVar, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.175930Structured0.400169Uncertain0.9450.2970.000-7.429In-Between0.480AmbiguousLikely Benign2.57Destabilizing0.12.38Destabilizing2.48Destabilizing1.21Destabilizing0.485Likely Benign-8.93Deleterious1.000Probably Damaging0.987Probably Damaging3.44Benign0.06Tolerated0.39650.1482-7-20.5-129.16
c.232C>G
R78G
2D
AIThe SynGAP1 R78G missense variant has no ClinVar entry and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support a benign status: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Taken together, the preponderance of evidence from both general and high‑accuracy predictors indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.505461Disordered0.448183Uncertain0.3040.8660.500-3.972Likely Benign0.480AmbiguousLikely Benign0.072Likely Benign-1.94Neutral0.385Benign0.028Benign3.83Benign0.00Affected0.32850.2986-3-24.1-99.14
c.2818G>C
G940R
2D
AIThe SynGAP1 missense variant G940R is listed in ClinVar (ID 1923639.0) as Benign and is present in gnomAD (6‑33443370‑G‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and Foldetta (FoldX‑MD/Rosetta stability assessment) has no available result for this variant. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as likely benign, and Foldetta data is unavailable. Overall, the majority of evidence points to a benign impact, which is consistent with the ClinVar classification and does not contradict it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.920635Binding0.3830.9020.625Benign 16-33443370-G-C53.10e-6-6.169Likely Benign0.480AmbiguousLikely Benign0.060Likely Benign0.02Neutral0.922Possibly Damaging0.543Possibly Damaging2.73Benign0.15Tolerated3.7750.09220.4024-3-2-4.199.14
c.3074A>G
Q1025R
2D
AIThe SynGAP1 missense variant Q1025R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (both HumDiv and HumVar) predict a pathogenic outcome. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.879233Disordered0.993410Binding0.3630.7460.500-4.435Likely Benign0.480AmbiguousLikely Benign0.101Likely Benign-1.28Neutral0.818Possibly Damaging0.453Possibly Damaging2.72Benign0.10Tolerated0.13420.265611-1.028.06
c.3662G>T
R1221L
2D
AIThe SynGAP1 missense variant R1221L is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FATHMM, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. Two tools, ESM1b and AlphaMissense‑Default, return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized predicts a benign outcome, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is uncertain because it receives one benign, one pathogenic, and two uncertain votes. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of conventional predictors lean toward pathogenicity, whereas the single high‑accuracy tool predicts benign and the consensus remains inconclusive. Thus, the variant is most likely pathogenic based on the available predictions, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.690604Disordered0.430363Uncertain0.9060.5390.375-7.995In-Between0.480AmbiguousLikely Benign0.150Likely Benign-3.71Deleterious0.992Probably Damaging0.866Possibly Damaging2.55Benign0.05Affected0.15570.3206-3-28.3-43.03
c.485G>A
R162H
2D
AIThe SynGAP1 missense variant R162H is listed in ClinVar with an uncertain significance and is present in the gnomAD database (variant ID 6‑33432782‑G‑A). Functional prediction tools cluster into two groups: benign calls are made by REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized, whereas pathogenic calls come from polyPhen‑2 (HumDiv and HumVar) and ESM1b; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also yields a benign verdict. Foldetta, a protein‑folding stability method that integrates FoldX‑MD and Rosetta outputs, did not provide a result for this variant. Overall, the preponderance of evidence points to a benign effect, which does not contradict the ClinVar uncertain classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.501700Disordered0.516348Binding0.3150.6920.250Uncertain 16-33432782-G-A21.24e-6-9.730Likely Pathogenic0.480AmbiguousLikely Benign0.167Likely Benign-1.13Neutral0.957Probably Damaging0.513Possibly Damaging4.03Benign0.12Tolerated3.7440.29810.2872201.3-19.05
c.1175A>C
K392T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant K392T is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include Rosetta, Foldetta, premPS, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are REVEL, PROVEAN, and SIFT. Two tools—FoldX and AlphaMissense‑Default—return uncertain results and are treated as unavailable. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign; and Foldetta, a protein‑folding stability method, also predicts benign. No ClinVar entry exists to contradict these predictions. Based on the collective evidence, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.541878Disordered0.405672Uncertain0.3190.7020.750-3.224Likely Benign0.481AmbiguousLikely Benign0.52Ambiguous0.1-0.29Likely Benign0.12Likely Benign0.05Likely Benign0.512Likely Pathogenic-3.14Deleterious0.276Benign0.045Benign4.60Benign0.02Affected0.28070.40530-13.2-27.07
c.2096T>G
V699G
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V699G has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include FATHMM and AlphaMissense‑Optimized, while the remaining tools (REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b) uniformly predict a pathogenic impact. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a pathogenic verdict; and Foldetta also predicts pathogenic. Consequently, the variant is most likely pathogenic based on the collective predictions, and this assessment does not contradict any ClinVar status, as none is available.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.069024Structured0.432975Uncertain0.9350.3150.000-11.912Likely Pathogenic0.481AmbiguousLikely Benign2.22Destabilizing0.03.25Destabilizing2.74Destabilizing1.77Destabilizing0.514Likely Pathogenic-5.11Deleterious0.972Probably Damaging0.999Probably Damaging3.37Benign0.01Affected0.18300.2240-1-3-4.6-42.08
c.2272T>G
Y758D
2D
AIThe SynGAP1 missense variant Y758D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized independently predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence—including the high‑accuracy tools—points to a benign effect. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical databases.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.517562Disordered0.856063Binding0.2890.8710.375-3.688Likely Benign0.481AmbiguousLikely Benign0.160Likely Benign-1.89Neutral0.973Probably Damaging0.796Possibly Damaging2.71Benign0.02Affected0.46470.0331-4-3-2.2-48.09
c.2498A>C
K833T
2D
AIThe SynGAP1 missense variant K833T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic outcome. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized independently predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Based on the aggregate predictions, K833T is most likely benign, and this assessment does not contradict any ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.625797Binding0.3150.8630.375-1.741Likely Benign0.481AmbiguousLikely Benign0.142Likely Benign-1.65Neutral0.990Probably Damaging0.921Probably Damaging2.60Benign0.02Affected0.18480.33350-13.2-27.07
c.3867G>C
K1289N
2D
AIThe SynGAP1 missense variant K1289N is reported in ClinVar as “Not submitted” and is not present in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic call comes from SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, SGM‑Consensus also predicts likely benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Based on the collective predictions, K1289N is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.828700Binding0.5480.7870.625-4.244Likely Benign0.481AmbiguousLikely Benign0.043Likely Benign-1.56Neutral0.224Benign0.120Benign2.59Benign0.02Affected0.34420.0940100.4-14.07
c.3867G>T
K1289N
2D
AIThe SynGAP1 missense variant K1289N is reported in ClinVar as “Not submitted” and is not present in gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic call comes from SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign outcome. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, SGM‑Consensus also predicts likely benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Based on the collective predictions, K1289N is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.733139Disordered0.828700Binding0.5480.7870.625-4.244Likely Benign0.481AmbiguousLikely Benign0.043Likely Benign-1.56Neutral0.224Benign0.120Benign2.59Benign0.02Affected0.34420.0940100.4-14.07
c.472C>A
Q158K
2D
AIThe SynGAP1 missense variant Q158K is not reported in ClinVar and has no entry in gnomAD, indicating it is not catalogued in these databases. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, which aggregates the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as likely benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, SGM‑Consensus indicates likely benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Overall, the computational evidence strongly suggests the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.527565Binding0.2860.7500.375-6.795Likely Benign0.481AmbiguousLikely Benign0.069Likely Benign-0.86Neutral0.276Benign0.121Benign4.20Benign0.15Tolerated0.18510.386911-0.40.04
c.502C>G
H168D
2D
AIThe SynGAP1 missense variant H168D is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Optimized. Only ESM1b predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign consensus, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This prediction is consistent with the lack of ClinVar annotation and does not contradict any existing clinical database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.433034Structured0.502450Binding0.4020.6780.125-8.519Likely Pathogenic0.481AmbiguousLikely Benign0.131Likely Benign-1.24Neutral0.016Benign0.021Benign4.24Benign0.08Tolerated0.23650.20171-1-0.3-22.05
c.77G>A
G26E
2D
AIThe SynGAP1 missense variant G26E is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus, SGM‑Consensus, classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the lack of ClinVar annotation; there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.486429Structured0.438291Uncertain0.3510.8780.375-3.966Likely Benign0.481AmbiguousLikely Benign0.199Likely Benign-2.08Neutral0.994Probably Damaging0.986Probably Damaging3.90Benign0.00Affected0.16230.42380-2-3.172.06
c.2126T>G
L709R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L709R is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, PROVEAN, SIFT, polyPhen‑2 HumVar, and FATHMM. Those that predict a pathogenic effect are polyPhen‑2 HumDiv and ESM1b. Tools with uncertain or inconclusive results are Rosetta, premPS, and AlphaMissense‑Default. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign consensus; and Foldetta (combining FoldX‑MD and Rosetta outputs) also predicts benign. Overall, the majority of evidence indicates a benign impact for the variant, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.243554Structured0.365830Uncertain0.9340.3790.000-8.636Likely Pathogenic0.482AmbiguousLikely Benign0.22Likely Benign0.00.68Ambiguous0.45Likely Benign0.62Ambiguous0.061Likely Benign-1.56Neutral0.906Possibly Damaging0.314Benign3.50Benign0.44Tolerated0.11270.0488-3-2-8.343.03
c.2168C>A
T723K
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T723K is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict benign. Only polyPhen‑2 HumDiv indicates a pathogenic outcome, while FoldX and AlphaMissense‑Default are uncertain. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, the SGM Consensus is Likely Benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts benign. Overall, the preponderance of evidence supports a benign classification for T723K, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.476583Structured0.458243Uncertain0.9450.4470.375-4.624Likely Benign0.482AmbiguousLikely Benign-0.77Ambiguous0.1-0.04Likely Benign-0.41Likely Benign0.25Likely Benign0.121Likely Benign-1.40Neutral0.674Possibly Damaging0.118Benign3.46Benign0.51Tolerated0.09240.27980-1-3.227.07
c.229A>C
S77R
2D
AIThe SynGAP1 missense variant S77R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (majority of the high‑accuracy tools) also indicates Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the collective evidence points to a benign effect for S77R, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.490133Structured0.446124Uncertain0.3100.8550.375-2.823Likely Benign0.482AmbiguousLikely Benign0.011Likely Benign-1.22Neutral0.198Benign0.015Benign4.09Benign0.00Affected0.07520.32470-1-3.769.11
c.231T>A
S77R
2D
AIThe SynGAP1 missense variant S77R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority of the high‑accuracy tools) is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.490133Structured0.446124Uncertain0.3100.8550.375-2.823Likely Benign0.482AmbiguousLikely Benign0.026Likely Benign-1.22Neutral0.198Benign0.015Benign4.09Benign0.00Affected0.07520.32470-1-3.769.11
c.231T>G
S77R
2D
AIThe SynGAP1 missense variant S77R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is classified as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (majority of the high‑accuracy tools) is also benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.490133Structured0.446124Uncertain0.3100.8550.375-2.823Likely Benign0.482AmbiguousLikely Benign0.026Likely Benign-1.22Neutral0.198Benign0.015Benign4.09Benign0.00Affected0.07520.32470-1-3.769.11
c.2369C>T
T790I
2D
AIThe SynGAP1 missense variant T790I is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is pathogenic. Foldetta, which would provide a protein‑folding stability estimate, has no available result for this variant. Overall, the majority of evidence points to a pathogenic impact. This conclusion does not contradict the ClinVar status, which currently has no classification for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.964893Disordered0.509280Binding0.3850.8960.875-3.556Likely Benign0.482AmbiguousLikely Benign0.190Likely Benign-3.08Deleterious0.999Probably Damaging0.997Probably Damaging2.28Pathogenic0.01Affected0.09870.54310-15.212.05
c.118G>T
D40Y
2D
AIThe SynGAP1 D40Y missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus indicates Likely Benign, and Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign effect for D40Y, and this conclusion does not contradict any existing ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.384043Structured0.432002Uncertain0.3190.7690.375-4.313Likely Benign0.483AmbiguousLikely Benign0.182Likely Benign-1.72Neutral0.388Benign0.328Benign3.98Benign0.00Affected0.11730.7918-4-32.248.09
c.3278A>G
Q1093R
2D
AIThe SynGAP1 missense variant Q1093R is reported in gnomAD (ID 6‑33443830‑A‑G) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic prediction comes from SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as likely benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is not contradicted by any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983312Binding0.3510.8861.0006-33443830-A-G16.40e-7-3.681Likely Benign0.483AmbiguousLikely Benign0.065Likely Benign-1.06Neutral0.224Benign0.091Benign2.73Benign0.04Affected3.7750.15370.390411-1.028.06
c.3437C>T
P1146L
2D
AISynGAP1 missense variant P1146L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include ESM1b, FATHMM, and AlphaMissense‑Optimized, whereas a separate group predicts pathogenicity: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), and SIFT. AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also favors a benign outcome, while Foldetta results are unavailable. Overall, the majority of conventional predictors indicate pathogenicity, but the most accurate tools lean benign. Thus, the variant is most likely pathogenic based on the collective predictions, and this assessment does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.919029Disordered0.732173Binding0.4150.8371.000-2.182Likely Benign0.483AmbiguousLikely Benign0.564Likely Pathogenic-5.25Deleterious0.992Probably Damaging0.912Probably Damaging5.51Benign0.00Affected0.21510.6446-3-35.416.04
c.3637A>T
N1213Y
2D
AIThe SynGAP1 missense variant N1213Y is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FATHMM, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. AlphaMissense‑Default is uncertain. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as pathogenic. AlphaMissense‑Optimized predicts benign, while high‑accuracy folding‑stability predictions from Foldetta are unavailable. Overall, more tools (five) predict pathogenicity than benign (three), and the consensus and high‑accuracy methods lean toward pathogenic. Therefore, the variant is most likely pathogenic based on current predictions, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.580690Disordered0.521638Binding0.8880.5610.500-8.972Likely Pathogenic0.483AmbiguousLikely Benign0.083Likely Benign-2.67Deleterious0.920Possibly Damaging0.657Possibly Damaging2.68Benign0.02Affected0.04390.3681-2-22.249.07
c.1309C>A
P437T
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 P437T missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, Rosetta, FATHMM, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. The remaining tools—FoldX, Foldetta, premPS, and AlphaMissense‑Default—return uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized predicting benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicting pathogenic, and Foldetta yielding an uncertain stability change. Overall, the majority of evidence points toward a pathogenic impact, and this conclusion does not contradict the lack of ClinVar annotation. Thus, the variant is most likely pathogenic based on current predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.175930Structured0.306196Uncertain0.9210.2980.000-13.011Likely Pathogenic0.484AmbiguousLikely Benign1.35Ambiguous0.0-3.46Stabilizing-1.06Ambiguous0.54Ambiguous0.305Likely Benign-6.67Deleterious0.999Probably Damaging0.985Probably Damaging3.45Benign0.01Affected0.16590.57820-10.93.99
c.2095G>A
V699M
2D
3DClick to see structure in 3D Viewer
AISynGAP1 variant V699M is listed in ClinVar with an uncertain significance and is present in gnomAD (ID 6‑33441354‑G‑A). Across in silico predictors, benign calls are made by REVEL, Rosetta, Foldetta, PROVEAN, FATHMM, and AlphaMissense‑Optimized, whereas pathogenic calls come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. Predictions that are inconclusive (FoldX, premPS, AlphaMissense‑Default) are noted but not used as evidence. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) reports benign stability. Overall, the preponderance of evidence indicates the variant is most likely benign, which does not contradict the ClinVar uncertain status but provides a stronger leaning toward benignity.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.069024Structured0.432975Uncertain0.9350.3150.000Uncertain 26-33441354-G-A84.96e-6-8.869Likely Pathogenic0.484AmbiguousLikely Benign-0.58Ambiguous0.10.29Likely Benign-0.15Likely Benign0.96Ambiguous0.276Likely Benign-2.18Neutral0.994Probably Damaging0.806Possibly Damaging3.37Benign0.03Affected3.47100.07340.307121-2.332.06257.8-47.20.00.00.90.1XPotentially BenignThe isopropyl side chain of Val699, located on an α-helix (res. Leu685-Gln702), packs against hydrophobic residues (e.g., Leu703, Leu696, Leu435, Leu439) in the inter-helix space. In the variant simulations, the thioether side chain of Met699 has similar physicochemical properties to Val699 in the WT, and thus, it is able to maintain similar interactions. Consequently, the mutation causes no apparent changes in the structure.
c.74G>T
R25L
2D
AIThe SynGAP1 missense variant R25L is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in‑silico predictors shows a predominance of benign calls: REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict a benign effect, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates a likely benign outcome. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT each predict a pathogenic impact. AlphaMissense‑Default remains uncertain, and no Foldetta stability assessment is available. High‑accuracy tools specifically highlight a benign prediction: AlphaMissense‑Optimized is benign, the SGM‑Consensus is likely benign, and Foldetta data are missing. Taken together, the majority of robust predictors and the consensus analysis support a benign classification for R25L. This conclusion is consistent with the lack of ClinVar evidence and does not contradict any existing database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.461924Structured0.438941Uncertain0.3730.8900.375-3.443Likely Benign0.484AmbiguousLikely Benign0.121Likely Benign-1.59Neutral0.686Possibly Damaging0.630Possibly Damaging3.97Benign0.00Affected0.20450.4792-3-28.3-43.03
c.2584A>T
N862Y
2D
AIThe SynGAP1 missense variant N862Y is not reported in ClinVar (ClinVar status: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) favors pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the balance of evidence—especially the high‑accuracy consensus—suggests the variant is most likely pathogenic, and this conclusion does not contradict any existing ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.525368Disordered0.564559Binding0.2570.7910.250-8.200Likely Pathogenic0.485AmbiguousLikely Benign0.216Likely Benign-3.06Deleterious0.999Probably Damaging0.992Probably Damaging4.01Benign0.06Tolerated0.08710.6246-2-22.249.07
c.2723A>G
Q908R
2D
AIThe SynGAP1 missense variant Q908R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (both HumDiv and HumVar) predict a pathogenic outcome. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status because none is available.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.608892Disordered0.678728Binding0.2750.9170.250-4.284Likely Benign0.485AmbiguousLikely Benign0.170Likely Benign-1.02Neutral0.985Probably Damaging0.982Probably Damaging2.75Benign0.10Tolerated0.13910.174311-1.028.06
c.3754C>G
Q1252E
2D
AIThe SynGAP1 missense variant Q1252E is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicting benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) predicts pathogenic. Foldetta results are unavailable. Overall, the majority of predictions (five pathogenic vs. three benign) lean toward pathogenicity, and this conclusion does not contradict the ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.759478Disordered0.371411Uncertain0.8500.5440.875-10.181Likely Pathogenic0.485AmbiguousLikely Benign0.152Likely Benign-2.32Neutral0.985Probably Damaging0.981Probably Damaging2.01Pathogenic0.00Affected0.11300.1266220.00.98
c.47T>G
M16R
2D
AIThe SynGAP1 missense variant M16R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic call comes from SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as likely benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, the SGM‑Consensus also indicates likely benign, and no Foldetta stability data are available. Taken together, the preponderance of evidence supports a benign classification for M16R, and this conclusion does not conflict with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.440853Structured0.459925Uncertain0.3460.9080.375-1.475Likely Benign0.485AmbiguousLikely Benign0.191Likely Benign-0.25Neutral0.014Benign0.003Benign4.21Benign0.00Affected0.19920.10930-1-6.424.99
c.2280G>A
M760I
2D
AIThe SynGAP1 missense variant M760I is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the collective evidence strongly suggests that M760I is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.541878Disordered0.893402Binding0.3460.8650.375-3.696Likely Benign0.486AmbiguousLikely Benign0.065Likely Benign-1.03Neutral0.029Benign0.033Benign2.67Benign0.09Tolerated0.15950.4054212.6-18.03
c.2280G>C
M760I
2D
AIThe SynGAP1 missense variant M760I is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the collective evidence strongly suggests that M760I is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.541878Disordered0.893402Binding0.3460.8650.375-3.696Likely Benign0.486AmbiguousLikely Benign0.065Likely Benign-1.03Neutral0.029Benign0.033Benign2.67Benign0.09Tolerated0.15950.4054212.6-18.03
c.2280G>T
M760I
2D
AIThe SynGAP1 missense variant M760I is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the collective evidence strongly suggests that M760I is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.541878Disordered0.893402Binding0.3460.8650.375-3.696Likely Benign0.486AmbiguousLikely Benign0.065Likely Benign-1.03Neutral0.029Benign0.033Benign2.67Benign0.09Tolerated0.15950.4054212.6-18.03
c.2346C>A
D782E
2D
AIThe SynGAP1 missense variant D782E is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign majority (2 benign vs. 1 pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact; this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.604312Disordered0.768342Binding0.2850.8830.625-4.447Likely Benign0.486AmbiguousLikely Benign0.127Likely Benign-1.75Neutral0.561Possibly Damaging0.207Benign2.14Pathogenic0.01Affected0.13510.7036320.014.03
c.2346C>G
D782E
2D
AIThe SynGAP1 missense variant D782E is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a majority benign vote (2 benign vs. 1 pathogenic). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact; this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.604312Disordered0.768342Binding0.2850.8830.625-4.447Likely Benign0.486AmbiguousLikely Benign0.127Likely Benign-1.75Neutral0.561Possibly Damaging0.207Benign2.14Pathogenic0.01Affected0.13510.7036320.014.03
c.3225G>C
Q1075H
2D
AIThe SynGAP1 missense variant Q1075H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, the SGM‑Consensus also indicates likely benign, while Foldetta data is missing. Overall, the majority of reliable predictors classify the variant as benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.988305Binding0.3540.8940.750-4.616Likely Benign0.486AmbiguousLikely Benign0.072Likely Benign-1.06Neutral0.996Probably Damaging0.992Probably Damaging2.68Benign0.13Tolerated0.14570.4214300.39.01
c.3225G>T
Q1075H
2D
AIThe SynGAP1 missense variant Q1075H is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, the SGM‑Consensus also indicates likely benign, while Foldetta data is missing. Overall, the majority of reliable predictors classify the variant as benign, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.922952Disordered0.988305Binding0.3540.8940.750-4.616Likely Benign0.486AmbiguousLikely Benign0.072Likely Benign-1.06Neutral0.996Probably Damaging0.992Probably Damaging2.68Benign0.13Tolerated0.14570.4214300.39.01
c.332C>T
P111L
2D
AIThe SynGAP1 missense variant P111L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also yields a benign prediction (2 benign vs. 1 pathogenic votes). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions indicates that P111L is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.707965Disordered0.650020Binding0.4380.8580.750-4.430Likely Benign0.486AmbiguousLikely Benign0.089Likely Benign-2.81Deleterious0.421Benign0.055Benign4.06Benign0.00Affected0.23550.7085-3-35.416.04
c.3581G>A
R1194K
2D
AIThe SynGAP1 missense variant R1194K is catalogued in gnomAD (6‑33444616‑G‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions are reported by both polyPhen‑2 HumDiv and HumVar. AlphaMissense‑Default is uncertain, and no Foldetta stability assessment is available. High‑accuracy evidence is consistent with benign impact: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus also indicates a likely benign outcome. In the absence of any pathogenic signal from these robust predictors and with no ClinVar classification to contradict, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.685117Disordered0.425297Uncertain0.7960.6020.3756-33444616-G-A16.21e-7-2.501Likely Benign0.486AmbiguousLikely Benign0.380Likely Benign-0.97Neutral0.979Probably Damaging0.982Probably Damaging5.56Benign0.14Tolerated3.7750.46370.3297230.6-28.01
c.3707A>G
Q1236R
2D
AIThe SynGAP1 missense variant Q1236R is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b all predict a pathogenic outcome; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the balance of evidence leans toward a benign classification, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.680603Disordered0.567914Binding0.8830.5370.125-8.186Likely Pathogenic0.486AmbiguousLikely Benign0.235Likely Benign-2.16Neutral0.994Probably Damaging0.988Probably Damaging2.69Benign0.01Affected0.11100.122811-1.028.06
c.1168G>T
G390W
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G390W is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include AlphaMissense‑Optimized, premPS, and PROVEAN, whereas the remaining tools—REVEL, FoldX, Rosetta, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM—consistently predict a pathogenic impact. High‑accuracy assessments further support pathogenicity: AlphaMissense‑Optimized predicts benign, but the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a pathogenic verdict, and Foldetta also indicates pathogenic. With the majority of evidence pointing to a deleterious effect, the variant is most likely pathogenic, and this conclusion does not contradict the ClinVar status, which currently contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.626927Disordered0.413274Uncertain0.3040.7630.875-9.405Likely Pathogenic0.487AmbiguousLikely Benign3.69Destabilizing1.95.31Destabilizing4.50Destabilizing0.14Likely Benign0.639Likely Pathogenic-1.11Neutral0.987Probably Damaging0.744Possibly Damaging1.31Pathogenic0.00Affected0.09170.4368-7-2-0.5129.16
c.2933C>G
P978R
2D
AIThe SynGAP1 missense variant P978R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, all of which classify the variant as benign. In contrast, polyPhen‑2 (HumDiv and HumVar) and SIFT predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports the variant as likely benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence from multiple independent predictors indicates that P978R is most likely benign, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.819762Disordered0.975775Binding0.4250.8920.625-2.852Likely Benign0.487AmbiguousLikely Benign0.105Likely Benign-2.10Neutral0.970Probably Damaging0.726Possibly Damaging4.15Benign0.01Affected0.15300.45900-2-2.959.07
c.3019A>T
S1007C
2D
AIThe SynGAP1 missense variant S1007C is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. Two tools—ESM1b and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is uncertain, and Foldetta’s stability prediction is unavailable. Overall, the balance of evidence (four benign versus three pathogenic predictions, with high‑accuracy tools favoring benign) indicates that the variant is most likely benign, and this conclusion does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.671169Disordered0.925648Binding0.2950.8990.750-7.399In-Between0.487AmbiguousLikely Benign0.132Likely Benign-1.91Neutral1.000Probably Damaging0.998Probably Damaging2.61Benign0.01Affected0.14050.51420-13.316.06
c.2047A>C
I683L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I683L is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are SIFT and ESM1b. Remaining methods (FoldX, Rosetta, Foldetta, premPS, AlphaMissense‑Default) give uncertain or inconclusive results and are treated as unavailable. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction, while Foldetta remains uncertain. Overall, the balance of evidence favors a benign impact for I683L, and this conclusion does not contradict any ClinVar annotation (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.200174Structured0.143268Uncertain0.8480.3140.000-9.988Likely Pathogenic0.488AmbiguousLikely Benign0.63Ambiguous0.10.76Ambiguous0.70Ambiguous0.69Ambiguous0.286Likely Benign-2.00Neutral0.011Benign0.056Benign3.43Benign0.04Affected0.09570.318522-0.70.00
c.2431C>A
P811T
2D
AIThe SynGAP1 missense variant P811T is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the majority of evidence points to a benign effect for P811T, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.411940Structured0.847064Binding0.3820.9100.250-5.329Likely Benign0.488AmbiguousLikely Benign0.119Likely Benign-1.94Neutral0.991Probably Damaging0.864Possibly Damaging2.77Benign0.03Affected0.16790.60950-10.93.99
c.2588T>G
L863R
2D
AIThe SynGAP1 missense variant L863R is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority of high‑accuracy predictors (AlphaMissense‑Optimized and the SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also support a benign classification. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact, but these are the only tools in disagreement. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. Overall, the preponderance of evidence points to a benign effect for the variant, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.525368Disordered0.594839Binding0.2670.7950.250-6.402Likely Benign0.488AmbiguousLikely Benign0.129Likely Benign-1.36Neutral0.999Probably Damaging0.977Probably Damaging4.02Benign0.09Tolerated0.12340.0947-3-2-8.343.03
c.3313C>T
R1105W
2D
AIThe SynGAP1 missense variant R1105W is listed in ClinVar with an uncertain significance and is present in gnomAD (ID 6‑33443865‑C‑T). Prediction tools show mixed results: benign calls come from REVEL, ESM1b, and AlphaMissense‑Optimized, while pathogenic calls are made by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. The AlphaMissense‑Default tool remains uncertain. A consensus analysis (SGM) that aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN yields a pathogenic majority. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts benign, whereas the SGM Consensus predicts pathogenic; Foldetta results are unavailable. Overall, the preponderance of evidence points to a pathogenic effect for R1105W, which does not conflict with the ClinVar designation of uncertain significance.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.901269Disordered0.954396Binding0.3300.8630.875Uncertain 16-33443865-C-T63.93e-6-6.911Likely Benign0.488AmbiguousLikely Benign0.133Likely Benign-4.34Deleterious0.999Probably Damaging0.696Possibly Damaging2.42Pathogenic0.02Affected3.7750.11540.4117-323.630.03
c.3569G>C
S1190T
2D
AIThe SynGAP1 missense variant S1190T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (both HumDiv and HumVar) predict a pathogenic outcome. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicates a likely benign classification. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.575842Disordered0.455760Uncertain0.7420.6240.625-4.362Likely Benign0.488AmbiguousLikely Benign0.320Likely Benign-1.02Neutral0.979Probably Damaging0.982Probably Damaging5.35Benign0.19Tolerated0.14520.4352110.114.03
c.3791G>T
G1264V
2D
AIThe SynGAP1 missense variant G1264V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.429200Structured0.762385Binding0.8970.5790.000-6.116Likely Benign0.488AmbiguousLikely Benign0.136Likely Benign-2.33Neutral0.966Probably Damaging0.617Possibly Damaging2.74Benign0.15Tolerated0.09720.3891-1-34.642.08
c.902C>A
A301D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A301D is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in‑silico predictors shows a predominance of benign calls: REVEL, FoldX, premPS, PROVEAN, SIFT, and FATHMM all predict benign, whereas polyPhen‑2 (HumDiv and HumVar) and ESM1b predict pathogenic. Tools with uncertain outputs—Rosetta, Foldetta, and AlphaMissense‑Default—do not provide decisive evidence. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized classifies the variant as benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also yields a benign verdict; Foldetta remains inconclusive. Taken together, the preponderance of evidence indicates that A301D is most likely benign, and this assessment does not conflict with the absence of a ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.429200Structured0.258424Uncertain0.6470.2720.375-10.276Likely Pathogenic0.488AmbiguousLikely Benign-0.37Likely Benign0.2-1.15Ambiguous-0.76Ambiguous0.23Likely Benign0.224Likely Benign-0.35Neutral0.999Probably Damaging0.995Probably Damaging4.17Benign0.07Tolerated0.15990.17050-2-5.344.01
c.1854G>C
Q618H
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant Q618H is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, Rosetta, premPS, PROVEAN, and AlphaMissense‑Optimized; pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. Four tools (FoldX, Foldetta, ESM1b, AlphaMissense‑Default) give uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, while the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive and Foldetta is uncertain. Overall, the majority of evidence points toward a benign effect, and this conclusion does not contradict the lack of ClinVar annotation or gnomAD presence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.175930Structured0.138725Uncertain0.9040.2400.000-7.092In-Between0.489AmbiguousLikely Benign0.59Ambiguous0.10.44Likely Benign0.52Ambiguous0.34Likely Benign0.475Likely Benign-1.99Neutral0.946Possibly Damaging0.638Possibly Damaging-1.35Pathogenic0.04Affected0.10150.2655300.39.01
c.1854G>T
Q618H
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q618H is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, Rosetta, premPS, PROVEAN, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. Four tools (FoldX, Foldetta, ESM1b, AlphaMissense‑Default) give uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive, and Foldetta is also uncertain. Overall, the balance of evidence leans toward a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.175930Structured0.138725Uncertain0.9040.2400.000-7.092In-Between0.489AmbiguousLikely Benign0.59Ambiguous0.10.44Likely Benign0.52Ambiguous0.34Likely Benign0.475Likely Benign-1.99Neutral0.946Possibly Damaging0.638Possibly Damaging-1.35Pathogenic0.04Affected0.10150.2655300.39.01
c.185A>T
D62V
2D
AIThe SynGAP1 missense variant D62V is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate a benign outcome, while the sole pathogenic signal comes from SIFT. AlphaMissense‑Default remains uncertain, and no Foldetta stability assessment is available. High‑accuracy methods reinforce the benign consensus: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports Likely Benign, and Foldetta data are missing. Taken together, the preponderance of evidence supports a benign classification for D62V, and this assessment does not conflict with the absence of a ClinVar entry. Therefore, the variant is most likely benign, and this conclusion does not contradict the ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.425610Structured0.476010Uncertain0.5750.7200.125-4.417Likely Benign0.489AmbiguousLikely Benign0.118Likely Benign-2.04Neutral0.028Benign0.088Benign4.04Benign0.00Affected0.10390.6129-2-37.7-15.96
c.2627C>T
S876L
2D
AISynGAP1 variant S876L is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions arise from PROVEAN, polyPhen‑2 (HumDiv and HumVar), and SIFT. AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts a benign effect; the SGM Consensus, derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive and therefore unavailable; Foldetta stability analysis is also unavailable. Overall, the majority of available predictions favor a benign impact, suggesting the variant is most likely benign. This conclusion does not conflict with the ClinVar uncertain status, which reflects the current lack of definitive evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.549308Disordered0.631130Binding0.2800.8720.250Uncertain 2-5.856Likely Benign0.489AmbiguousLikely Benign0.249Likely Benign-3.56Deleterious0.998Probably Damaging0.992Probably Damaging2.57Benign0.05Affected3.7750.12680.6053-2-34.626.08
c.3004C>T
H1002Y
2D
AIThe SynGAP1 missense variant H1002Y is not reported in ClinVar and is absent from gnomAD. Consensus from multiple in silico predictors indicates a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all score the change as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also classifies it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default tool remains uncertain, and no Foldetta stability assessment is available. High‑accuracy methods that are available—AlphaMissense‑Optimized and the SGM‑Consensus—both support a benign interpretation. Therefore, the variant is most likely benign based on the current predictive evidence, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.953758Binding0.2850.9000.500-6.159Likely Benign0.489AmbiguousLikely Benign0.181Likely Benign-1.85Neutral0.961Probably Damaging0.808Possibly Damaging2.74Benign0.14Tolerated0.12430.4427021.926.03
c.350G>A
S117N
2D
AIThe SynGAP1 missense variant S117N is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from multiple prediction algorithms and consensus analyses indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.661982Disordered0.672422Binding0.3570.8770.625-5.704Likely Benign0.489AmbiguousLikely Benign0.067Likely Benign-1.06Neutral0.005Benign0.003Benign3.71Benign0.01Affected0.14910.453011-2.727.03
c.1192C>T
P398S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 P398S missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include polyPhen‑2 (HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are REVEL, PROVEAN, polyPhen‑2 (HumDiv), and SIFT. The remaining tools (FoldX, Rosetta, Foldetta, premPS, AlphaMissense‑Default) give uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta as uncertain. Overall, the majority of definitive predictions lean toward a benign impact, and this conclusion does not contradict the lack of ClinVar annotation. Thus, the variant is most likely benign based on current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.436924Structured0.401041Uncertain0.8910.5250.250-6.757Likely Benign0.490AmbiguousLikely Benign1.86Ambiguous0.31.78Ambiguous1.82Ambiguous0.85Ambiguous0.544Likely Pathogenic-5.58Deleterious0.478Possibly Damaging0.130Benign5.68Benign0.03Affected0.36190.57371-10.8-10.04
c.1540A>C
I514L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I514L is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Two tools (premPS and AlphaMissense‑Default) give uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign, and Foldetta also predicts a benign outcome. No prediction or folding stability result is missing or inconclusive. Overall, the majority of evidence points to a benign impact, and this is consistent with the lack of ClinVar annotation—there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.049374Structured0.221408Uncertain0.9480.2660.000-10.239Likely Pathogenic0.490AmbiguousLikely Benign-0.05Likely Benign0.20.34Likely Benign0.15Likely Benign0.81Ambiguous0.310Likely Benign-1.99Neutral0.879Possibly Damaging0.985Probably Damaging3.31Benign0.12Tolerated0.07670.267822-0.70.00
c.2927T>G
F976C
2D
AIThe SynGAP1 missense variant F976C is not reported in ClinVar and is absent from gnomAD. In silico predictors cluster into two groups: benign predictions come from REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, whereas pathogenic predictions arise from polyPhen‑2 HumDiv and polyPhen‑2 HumVar. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign and the SGM‑Consensus likewise indicates Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for F976C, and this conclusion is not in conflict with the absence of a ClinVar assertion.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.876521Disordered0.975061Binding0.3110.8940.625-5.490Likely Benign0.490AmbiguousLikely Benign0.103Likely Benign-1.10Neutral0.977Probably Damaging0.840Possibly Damaging4.09Benign0.10Tolerated0.29610.2505-4-2-0.3-44.04
c.784A>T
N262Y
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant N262Y is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include premPS, FATHMM, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. The remaining tools (FoldX, Rosetta, Foldetta, AlphaMissense‑Default) are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the majority of predictions (seven pathogenic vs. three benign) lean toward a pathogenic impact, and this conclusion does not contradict the ClinVar status, which is currently unreported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.284882Structured0.399879Uncertain0.9120.2400.000-12.177Likely Pathogenic0.490AmbiguousLikely Benign1.86Ambiguous0.50.52Ambiguous1.19Ambiguous0.36Likely Benign0.858Likely Pathogenic-6.48Deleterious0.999Probably Damaging0.996Probably Damaging5.85Benign0.01Affected0.04450.3877-2-22.249.07
c.1339G>C
V447L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V447L is listed in ClinVar with an “Uncertain” status and is not reported in gnomAD. Prediction tools that classify the variant as benign include REVEL, Foldetta, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (Likely Benign). Tools that predict pathogenicity are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Uncertain results are reported by FoldX, Rosetta, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, the SGM‑Consensus as Likely Benign, and Foldetta as Benign. Overall, the majority of evidence points to a benign effect, and this consensus does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.250310Structured0.283801Uncertain0.9700.2430.000Uncertain 1-5.136Likely Benign0.491AmbiguousLikely Benign-1.13Ambiguous0.10.54Ambiguous-0.30Likely Benign0.03Likely Benign0.180Likely Benign-0.29Neutral0.947Possibly Damaging0.851Possibly Damaging3.61Benign0.90Tolerated3.37320.07570.347712-0.414.03
c.1732G>C
E578Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 E578Q missense variant is not reported in ClinVar and is absent from gnomAD. Consensus from most in silico predictors indicates a benign effect: REVEL, FoldX, Rosetta, premPS, PROVEAN, SIFT, AlphaMissense‑Optimized, and Foldetta all predict benign. Pathogenic predictions come from polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. AlphaMissense‑Default remains uncertain. High‑accuracy assessment shows AlphaMissense‑Optimized as benign, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—leans pathogenic. Foldetta, a protein‑folding stability method, also predicts benign. Overall, the majority of tools, including the high‑accuracy AlphaMissense‑Optimized and Foldetta, support a benign classification, and this is consistent with the lack of ClinVar evidence. Thus, the variant is most likely benign and does not contradict ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.059222Structured0.020971Uncertain0.9020.2400.000-9.771Likely Pathogenic0.491AmbiguousLikely Benign0.01Likely Benign0.1-0.12Likely Benign-0.06Likely Benign-0.16Likely Benign0.353Likely Benign-1.21Neutral0.994Probably Damaging0.986Probably Damaging-1.40Pathogenic0.36Tolerated0.10000.5319220.0-0.98
c.2432C>T
P811L
2D
AIThe SynGAP1 P811L missense variant has no ClinVar entry and is not reported in gnomAD. Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are PROVEAN, polyPhen‑2 (HumDiv and HumVar), and SIFT. AlphaMissense‑Default is uncertain. The SGM Consensus, which takes a majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, leans toward benign (2 benign vs. 1 pathogenic, 1 uncertain). AlphaMissense‑Optimized also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence from high‑accuracy tools and consensus methods indicates that P811L is most likely benign. This assessment does not contradict ClinVar status, as the variant is not yet reported there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.411940Structured0.847064Binding0.3820.9100.250-6.184Likely Benign0.491AmbiguousLikely Benign0.150Likely Benign-3.98Deleterious0.982Probably Damaging0.824Possibly Damaging2.71Benign0.01Affected0.23270.6621-3-35.416.04
c.2708G>T
G903V
2D
AIThe SynGAP1 missense variant G903V is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM. AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also predicts benign, while Foldetta results are unavailable. Overall, the balance of evidence (five benign predictions versus three pathogenic predictions, with no conflicting ClinVar annotation) indicates that the variant is most likely benign. This conclusion does not contradict any ClinVar status, as the variant is not currently catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.680603Disordered0.549818Binding0.2910.9170.375-4.750Likely Benign0.491AmbiguousLikely Benign0.168Likely Benign-1.93Neutral0.997Probably Damaging0.959Probably Damaging2.44Pathogenic0.95Tolerated0.12690.4266-1-34.642.08
c.3517A>T
I1173F
2D
AIThe SynGAP1 missense variant I1173F is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (both HumDiv and HumVar) predict a pathogenic outcome. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign classification. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect for I1173F, and this conclusion does not contradict any ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.501700Disordered0.653145Binding0.5210.7560.375-3.635Likely Benign0.491AmbiguousLikely Benign0.365Likely Benign-0.87Neutral0.934Possibly Damaging0.636Possibly Damaging5.39Benign0.13Tolerated0.05670.210810-1.734.02
c.1367A>T
Q456L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q456L is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, Rosetta, premPS, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Tools with uncertain or inconclusive results are FoldX, Foldetta, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the majority of predictions (six benign vs. four pathogenic) lean toward a benign interpretation, with no evidence of contradiction with the ClinVar status. Thus, the variant is most likely benign based on current computational predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.170161Structured0.302348Uncertain0.9390.1640.000-10.272Likely Pathogenic0.492AmbiguousLikely Benign-0.88Ambiguous0.1-0.30Likely Benign-0.59Ambiguous0.28Likely Benign0.347Likely Benign-6.65Deleterious0.987Probably Damaging0.914Probably Damaging3.49Benign0.36Tolerated0.05540.4317-2-27.3-14.97
c.1412C>T
S471F
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S471F is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, premPS, and AlphaMissense‑Optimized, while pathogenic predictions are made by PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. The remaining tools—AlphaMissense‑Default, FoldX, Rosetta, and Foldetta—return uncertain or inconclusive results. High‑accuracy assessments further clarify the picture: AlphaMissense‑Optimized predicts a benign effect; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, indicates a likely pathogenic outcome; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, yields an uncertain result. Taken together, the majority of evidence points toward a pathogenic impact for S471F, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.305330Structured0.355411Uncertain0.8880.2610.000-10.777Likely Pathogenic0.492AmbiguousLikely Benign-0.54Ambiguous0.1-1.51Ambiguous-1.03Ambiguous0.12Likely Benign0.423Likely Benign-4.75Deleterious0.942Possibly Damaging0.487Possibly Damaging-1.26Pathogenic0.02Affected0.05530.4691-3-23.660.10
c.1601C>T
S534F
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S534F is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that classify the variant as benign include REVEL, FoldX, Foldetta, premPS, FATHMM, and AlphaMissense‑Optimized. Those that predict pathogenicity are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b. Tools with uncertain results are AlphaMissense‑Default and Rosetta. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as pathogenic. Overall, the majority of predictions lean toward a benign effect, and this is consistent with the lack of ClinVar evidence; thus the variant is most likely benign and does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.167087Structured0.032173Uncertain0.8600.3620.000-10.948Likely Pathogenic0.492AmbiguousLikely Benign-0.03Likely Benign0.10.88Ambiguous0.43Likely Benign0.43Likely Benign0.313Likely Benign-5.09Deleterious0.998Probably Damaging0.998Probably Damaging3.26Benign0.00Affected0.06210.5379-3-23.660.10
c.2330T>A
L777H
2D
AIThe SynGAP1 missense variant L777H has no ClinVar record and is not present in gnomAD. Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors a benign outcome. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the balance of evidence—including the consensus of high‑accuracy tools—suggests that the variant is most likely benign, and this assessment does not contradict the ClinVar status, which currently contains no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.408655Structured0.876129Binding0.3360.8820.250-6.719Likely Benign0.492AmbiguousLikely Benign0.230Likely Benign-2.51Deleterious0.997Probably Damaging0.993Probably Damaging3.95Benign0.00Affected0.10520.0972-2-3-7.023.98
c.2449T>A
S817T
2D
AIThe SynGAP1 missense variant S817T is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also leans benign, and Foldetta results are unavailable. Overall, the balance of evidence from both general and high‑accuracy predictors points to a benign impact for S817T. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.490133Structured0.727082Binding0.3140.9010.625-6.544Likely Benign0.492AmbiguousLikely Benign0.157Likely Benign-1.95Neutral0.990Probably Damaging0.846Possibly Damaging2.43Pathogenic0.00Affected0.16220.6482110.114.03
c.2600G>A
G867E
2D
AIThe SynGAP1 missense variant G867E is catalogued in gnomAD (6‑33443152‑G‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions are reported by polyPhen‑2 HumDiv and polyPhen‑2 HumVar, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign effect, and this conclusion does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.517562Disordered0.657954Binding0.2850.8010.2506-33443152-G-A31.86e-6-5.204Likely Benign0.492AmbiguousLikely Benign0.105Likely Benign-1.57Neutral0.994Probably Damaging0.943Probably Damaging2.74Benign0.07Tolerated3.8240.13050.3880-20-3.172.06
c.3398T>G
I1133S
2D
AIThe SynGAP1 missense variant I1133S is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign classification. High‑accuracy assessments confirm this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is likely benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the collective evidence strongly supports a benign impact for I1133S, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.832785Binding0.3160.8920.750-4.034Likely Benign0.492AmbiguousLikely Benign0.186Likely Benign-0.60Neutral0.007Benign0.016Benign5.70Benign0.08Tolerated0.27620.1110-1-2-5.3-26.08
c.52T>A
Y18N
2D
AIThe SynGAP1 missense variant Y18N is listed in gnomAD (ID 6‑33420316‑T‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none is reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.483068Structured0.446314Uncertain0.3450.9080.3756-33420316-T-A-3.094Likely Benign0.492AmbiguousLikely Benign0.075Likely Benign-0.73Neutral0.872Possibly Damaging0.114Benign4.07Benign0.00Affected4.3210.25640.1253-2-2-2.2-49.07
c.1412C>A
S471Y
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant S471Y is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions from REVEL, FoldX, premPS, and AlphaMissense‑Optimized; pathogenic predictions from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. The high‑accuracy AlphaMissense‑Optimized scores the variant as benign, whereas the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—labels it as likely pathogenic. Foldetta, which integrates FoldX‑MD and Rosetta outputs, returns an uncertain stability change. No evidence from ClinVar contradicts these computational assessments. Overall, the preponderance of pathogenic predictions and the SGM Consensus suggest the variant is most likely pathogenic, consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.305330Structured0.355411Uncertain0.8880.2610.000-11.257Likely Pathogenic0.493AmbiguousLikely Benign-0.33Likely Benign0.1-1.31Ambiguous-0.82Ambiguous0.19Likely Benign0.446Likely Benign-4.79Deleterious0.980Probably Damaging0.584Possibly Damaging-1.27Pathogenic0.03Affected0.06070.4417-3-2-0.576.10
c.2306T>G
L769R
2D
AIThe SynGAP1 missense variant L769R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus as likely benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) is unavailable for this variant. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.411940Structured0.928432Binding0.3670.8830.250-6.245Likely Benign0.493AmbiguousLikely Benign0.206Likely Benign-1.66Neutral0.003Benign0.006Benign3.91Benign0.00Affected0.12860.0702-3-2-8.343.03
c.2639C>A
A880D
2D
AIThe SynGAP1 missense variant A880D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, the SGM Consensus (a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) indicating a likely benign outcome, and no Foldetta stability result is available. Based on the overall consensus of the available predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.703578Disordered0.621441Binding0.3090.8740.250-4.571Likely Benign0.493AmbiguousLikely Benign0.127Likely Benign-1.29Neutral0.918Possibly Damaging0.401Benign2.60Benign0.03Affected0.16640.19040-2-5.344.01
c.3008G>C
S1003T
2D
AIThe SynGAP1 missense variant S1003T is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority of pathogenic predictors—polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT—suggest a damaging impact. The AlphaMissense‑Default score is uncertain, and Foldetta stability analysis is unavailable. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely benign outcome. High‑accuracy assessments therefore lean toward a benign interpretation: AlphaMissense‑Optimized predicts benign, SGM‑Consensus is likely benign, and no Foldetta data is present. Overall, the computational evidence supports a benign classification, with no conflict with ClinVar status because no ClinVar assertion exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.834292Disordered0.947349Binding0.2720.9010.625-5.140Likely Benign0.493AmbiguousLikely Benign0.115Likely Benign-1.04Neutral0.992Probably Damaging0.987Probably Damaging2.51Benign0.00Affected0.18640.6227110.114.03
c.682A>T
T228S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 T228S missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Foldetta, premPS, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while Rosetta and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction, and Foldetta (combining FoldX‑MD and Rosetta outputs) reports a benign stability change. Taken together, the overwhelming majority of evidence indicates a benign impact for T228S. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing database status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignPH0.104810Structured0.321733Uncertain0.8290.3160.125-2.028Likely Benign0.493AmbiguousLikely Benign0.32Likely Benign0.10.63Ambiguous0.48Likely Benign0.05Likely Benign0.458Likely Benign-0.50Neutral0.734Possibly Damaging0.138Benign5.65Benign1.00Tolerated0.33950.510711-0.1-14.03
c.1289T>A
M430K
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M430K is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, Rosetta, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN and ESM1b. The remaining tools—FoldX, Foldetta, premPS, and AlphaMissense‑Default—return uncertain or inconclusive results. High‑accuracy methods give a mixed picture: AlphaMissense‑Optimized classifies the variant as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) favors a pathogenic outcome; Foldetta remains uncertain. Overall, the majority of individual predictors lean toward a benign interpretation, whereas the SGM Consensus suggests pathogenicity. Given the lack of ClinVar evidence, there is no contradiction with existing clinical annotations. Based on the aggregate predictions, the variant is most likely benign, and this assessment does not conflict with the current ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.071867Structured0.385298Uncertain0.9520.3060.000-10.816Likely Pathogenic0.494AmbiguousLikely Benign0.78Ambiguous0.10.44Likely Benign0.61Ambiguous0.86Ambiguous0.149Likely Benign-2.66Deleterious0.134Benign0.033Benign3.47Benign0.32Tolerated0.16600.12710-1-5.8-3.02
c.1511A>C
K504T
2D
3DClick to see structure in 3D Viewer
AISynGAP1 K504T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, SIFT, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Other tools (AlphaMissense‑Default, Foldetta, premPS, Rosetta) were inconclusive and are not considered evidence. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts benign. Overall, the majority of predictions support a pathogenic classification, and this is not contradicted by the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.028107Structured0.304984Uncertain0.8500.1890.000-9.572Likely Pathogenic0.494AmbiguousLikely Benign0.12Likely Benign0.3-0.85Ambiguous-0.37Likely Benign0.84Ambiguous0.498Likely Benign-5.36Deleterious0.961Probably Damaging0.990Probably Damaging-1.44Pathogenic0.10Tolerated0.14820.26190-13.2-27.07
c.2738C>G
T913R
2D
AIThe SynGAP1 missense variant T913R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of computational evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.661982Disordered0.763517Binding0.3390.8990.375-3.218Likely Benign0.494AmbiguousLikely Benign0.152Likely Benign-0.97Neutral1.000Probably Damaging0.999Probably Damaging2.68Benign0.03Affected0.10250.3373-1-1-3.855.08
c.218G>T
R73M
2D
AIThe SynGAP1 R73M missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus methods give a benign signal: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports “Likely Benign.” Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.501700Disordered0.453164Uncertain0.3320.8260.375-5.343Likely Benign0.495AmbiguousLikely Benign0.135Likely Benign-1.10Neutral0.872Possibly Damaging0.113Benign4.00Benign0.00Affected0.19100.42380-16.4-24.99
c.3346G>A
G1116R
2D
AIThe SynGAP1 missense variant G1116R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the majority of computational evidence points to a benign effect for G1116R, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.873279Binding0.3200.9090.750-6.379Likely Benign0.495AmbiguousLikely Benign0.368Likely Benign-0.60Neutral0.922Possibly Damaging0.657Possibly Damaging4.18Benign0.04Affected0.09250.4342-3-2-4.199.14
c.3346G>C
G1116R
2D
AIThe SynGAP1 missense variant G1116R is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the majority of computational evidence points to a benign effect for G1116R, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.889439Disordered0.873279Binding0.3200.9090.750-6.379Likely Benign0.495AmbiguousLikely Benign0.368Likely Benign-0.60Neutral0.922Possibly Damaging0.657Possibly Damaging4.18Benign0.04Affected0.09250.4342-3-2-4.199.14
c.517C>G
L173V
2D
AIThe SynGAP1 missense variant L173V is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Optimized. Only ESM1b predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign majority vote. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.534167Disordered0.491566Uncertain0.3900.6310.375-8.320Likely Pathogenic0.495AmbiguousLikely Benign0.100Likely Benign-0.95Neutral0.131Benign0.058Benign4.05Benign0.22Tolerated0.13430.3217210.4-14.03
c.605A>G
E202G
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 E202G missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, premPS, SIFT, and FATHMM. Those that predict a pathogenic impact are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Tools with uncertain or inconclusive results are Rosetta, AlphaMissense‑Default, and Foldetta. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) leans toward pathogenic (2 pathogenic, 1 benign, 1 uncertain). Foldetta remains uncertain. Overall, the majority of standard prediction tools suggest a benign effect, and this conclusion does not contradict the lack of ClinVar reporting. Thus, the variant is most likely benign based on the current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
PH0.363090Structured0.429450Uncertain0.7120.4150.125-8.310Likely Pathogenic0.495AmbiguousLikely Benign0.37Likely Benign0.00.74Ambiguous0.56Ambiguous0.27Likely Benign0.259Likely Benign-4.70Deleterious0.995Probably Damaging0.829Possibly Damaging4.01Benign0.07Tolerated0.30610.54050-23.1-72.06
c.1674C>A
H558Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant H558Q is not reported in ClinVar and has no entries in gnomAD. Prediction tools that classify the variant as benign include SIFT, FoldX, Rosetta, Foldetta, and AlphaMissense‑Optimized. Those that predict pathogenicity are SGM‑Consensus (Likely Pathogenic), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Two tools report uncertainty: AlphaMissense‑Default and premPS. High‑accuracy methods give mixed results: AlphaMissense‑Optimized predicts benign, SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts likely pathogenic, and Foldetta predicts benign. No prediction or folding stability result is missing. Overall, the majority of tools lean toward pathogenicity, but the presence of several benign predictions and conflicting high‑accuracy outputs suggests uncertainty. The variant is most likely pathogenic based on the prevailing evidence, and this assessment does not contradict the ClinVar status, which is currently unreported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.033407Structured0.011039Uncertain0.8970.2000.000-11.483Likely Pathogenic0.496AmbiguousLikely Benign-0.26Likely Benign0.10.05Likely Benign-0.11Likely Benign0.97Ambiguous0.522Likely Pathogenic-4.23Deleterious0.991Probably Damaging0.702Possibly Damaging-1.25Pathogenic0.13Tolerated0.11820.205830-0.3-9.01
c.1674C>G
H558Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant H558Q is not reported in ClinVar and has no entries in gnomAD. Prediction tools that classify the variant as benign include SIFT, FoldX, Rosetta, Foldetta, and AlphaMissense‑Optimized. Those that predict pathogenicity are SGM‑Consensus (Likely Pathogenic), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Two tools report uncertainty: AlphaMissense‑Default and premPS. High‑accuracy methods give mixed results: AlphaMissense‑Optimized predicts benign, SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts likely pathogenic, and Foldetta predicts benign. No prediction or folding stability result is missing. Overall, the majority of tools lean toward pathogenicity, but the presence of several benign predictions and conflicting high‑accuracy outputs suggests uncertainty. The variant is most likely pathogenic based on the prevailing evidence, and this assessment does not contradict the ClinVar status, which is currently unreported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.033407Structured0.011039Uncertain0.8970.2000.000-11.483Likely Pathogenic0.496AmbiguousLikely Benign-0.26Likely Benign0.10.05Likely Benign-0.11Likely Benign0.97Ambiguous0.522Likely Pathogenic-4.23Deleterious0.991Probably Damaging0.702Possibly Damaging-1.25Pathogenic0.13Tolerated0.11820.205830-0.3-9.01
c.1724G>A
R575H
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant R575H (ClinVar ID 1029088.0) is listed as Uncertain in ClinVar and is present in gnomAD (ID 6‑33440776‑G‑A). Prediction tools that indicate a benign effect include Rosetta, Foldetta, PROVEAN, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are REVEL, premPS, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Pathogenic. High‑accuracy assessments show AlphaMissense‑Optimized as Benign, Foldetta as Benign, and the SGM Consensus as Pathogenic. Overall, the majority of evidence points to a pathogenic impact, which contrasts with the ClinVar designation of Uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.061840Structured0.021362Uncertain0.9160.2590.000Conflicting 46-33440776-G-A2041.27e-4-11.142Likely Pathogenic0.496AmbiguousLikely Benign0.81Ambiguous0.2-0.22Likely Benign0.30Likely Benign1.31Destabilizing0.707Likely Pathogenic-2.34Neutral1.000Probably Damaging0.998Probably Damaging-1.33Pathogenic0.05Affected3.37350.23610.1292201.3-19.05244.780.60.00.00.30.0XPotentially PathogenicThe guanidinium group of Arg575, located in an α-helix (res. Arg563-Glu578), forms salt bridges with the carboxylate groups of Asp463 and Asp467, and it also hydrogen bonds with the hydroxyl group of Ser466 on an opposing α-helix (res. Ala461-Phe476) in the WT simulations. In the variant simulations, the imidazole ring of His575 (in its neutral epsilon protonated form) cannot form the same salt bridges as the guanidinium group of the non-mutated Arg575. Instead, His575 only forms weak hydrogen bonds with the hydroxyl groups of Ser466 and Ser571. Overall, the residue swap has the potential to substantially affect the tertiary structure assembly during the protein folding process.
c.2633C>G
T878R
2D
AIThe SynGAP1 missense variant T878R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar status because no ClinVar entry exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.622677Disordered0.628767Binding0.2880.8780.250-4.289Likely Benign0.496AmbiguousLikely Benign0.119Likely Benign-1.39Neutral0.611Possibly Damaging0.398Benign2.64Benign0.00Affected0.10060.2920-1-1-3.855.08
c.2677C>A
Q893K
2D
AIThe SynGAP1 missense variant Q893K is not reported in ClinVar and is absent from gnomAD. Functional prediction tools uniformly indicate a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all score the substitution as benign, and AlphaMissense‑Optimized also predicts a benign outcome. No tool predicts pathogenicity; AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as likely benign. High‑accuracy assessments corroborate this: AlphaMissense‑Optimized is benign, and the SGM‑Consensus is likely benign; Foldetta results are not available. Overall, the computational evidence strongly supports a benign classification, and this conclusion does not contradict ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.754692Disordered0.447267Uncertain0.3100.9250.750-5.622Likely Benign0.496AmbiguousLikely Benign0.053Likely Benign-1.45Neutral0.451Benign0.265Benign2.78Benign0.10Tolerated0.19010.438111-0.40.04
c.3511_3512delinsTG
A1171C
2D
AIThe SynGAP1 missense variant A1171C (ClinVar ID 1723483.0) is listed as “Uncertain” in ClinVar and is not present in gnomAD. Prediction tools that converge on a benign outcome include PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, all of which report a benign or neutral effect. In contrast, PolyPhen‑2 (HumDiv and HumVar) and SIFT uniformly predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is “Likely Benign,” reinforcing the benign signal. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM‑Consensus (majority vote) as benign, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, which does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.599170Disordered0.702689Binding0.4720.7750.500Uncertain 1-5.363Likely Benign0.496AmbiguousLikely Benign-1.16Neutral0.978Probably Damaging0.825Possibly Damaging5.32Benign0.02Affected4.3240.11020.4921-200.732.06
c.3686A>T
Q1229L
2D
AIThe SynGAP1 missense variant Q1229L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into three groups: benign predictions come from REVEL, SIFT, and AlphaMissense‑Optimized; pathogenic predictions arise from PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and FATHMM; the remaining tools (ESM1b and AlphaMissense‑Default) are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized classifying the variant as benign, while the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive, and Foldetta data are unavailable. Overall, the majority of conventional predictors favor a pathogenic effect, whereas the single high‑accuracy tool suggests benign. Given the lack of ClinVar evidence, the variant is most likely pathogenic according to the collective predictions, with no contradiction to existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.490133Structured0.466729Uncertain0.8650.5440.375-7.366In-Between0.496AmbiguousLikely Benign0.349Likely Benign-4.60Deleterious0.994Probably Damaging0.988Probably Damaging1.77Pathogenic0.09Tolerated0.05410.4253-2-27.3-14.97
c.4000A>C
N1334H
2D
AIThe SynGAP1 missense variant N1334H is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of reliable tools and the high‑accuracy consensus predict a benign impact. This conclusion is not contradicted by ClinVar, which contains no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.915074Disordered0.960403Binding0.4060.7340.875-4.954Likely Benign0.496AmbiguousLikely Benign0.164Likely Benign-2.99Deleterious0.985Probably Damaging0.927Probably Damaging3.50Benign0.00Affected0.19630.6246210.323.04
c.2023A>G
N675D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant N675D is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, Rosetta, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. High‑accuracy assessments give AlphaMissense‑Optimized a benign call, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) a pathogenic call, and Foldetta an uncertain result. With an equal split of general predictions but a pathogenic majority in the high‑accuracy consensus, the variant is most likely pathogenic. This assessment does not contradict ClinVar status, as no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.129801Structured0.111024Uncertain0.5130.3330.000-12.829Likely Pathogenic0.497AmbiguousLikely Benign1.41Ambiguous0.4-0.26Likely Benign0.58Ambiguous1.05Destabilizing0.246Likely Benign-3.87Deleterious0.997Probably Damaging0.865Possibly Damaging3.53Benign0.17Tolerated0.19140.4901210.00.98
c.3049T>G
F1017V
2D
AIThe SynGAP1 missense variant F1017V is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction. Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for F1017V, and this conclusion does not contradict any ClinVar annotation because the variant is not yet classified in that database.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.889439Disordered0.954171Binding0.3220.8010.625-2.517Likely Benign0.497AmbiguousLikely Benign0.161Likely Benign-2.97Deleterious0.905Possibly Damaging0.637Possibly Damaging2.51Benign0.03Affected0.19640.2137-1-11.4-48.04
c.3260C>T
S1087F
2D
AISynGAP1 missense variant S1087F is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Functional prediction tools show a split: benign calls come from REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic calls come from PROVEAN, polyPhen‑2 (HumDiv and HumVar), and SIFT; AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign trend: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of reliable predictors and the two high‑accuracy tools suggest a benign effect, which does not contradict the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.912647Disordered0.974805Binding0.3570.8911.000Uncertain 1-3.843Likely Benign0.497AmbiguousLikely Benign0.105Likely Benign-2.75Deleterious0.990Probably Damaging0.796Possibly Damaging2.56Benign0.03Affected3.7750.06450.6029-2-33.660.10
c.344A>G
Q115R
2D
AIThe SynGAP1 missense variant Q115R is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority of high‑accuracy predictors—AlphaMissense‑Optimized and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN)—also support a benign classification. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact, and AlphaMissense‑Default remains uncertain. No Foldetta stability analysis is available. Overall, the preponderance of evidence from both general and high‑accuracy tools points to a benign effect for Q115R. This assessment is consistent with the absence of a ClinVar claim, so there is no contradiction with existing clinical annotations.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.657256Binding0.3270.8780.750-1.429Likely Benign0.497AmbiguousLikely Benign0.109Likely Benign-0.46Neutral0.967Probably Damaging0.901Possibly Damaging4.12Benign0.24Tolerated0.14690.150711-1.028.06
c.961C>A
R321S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant R321S is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, Rosetta, Foldetta, premPS, PROVEAN, SIFT, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. Two tools—FoldX and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as benign. Overall, the majority of predictions lean toward a benign impact, and this conclusion does not contradict the lack of ClinVar annotation. Thus, the variant is most likely benign based on the available computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.175930Structured0.423273Uncertain0.9310.2970.125-10.146Likely Pathogenic0.497AmbiguousLikely Benign0.66Ambiguous0.1-0.30Likely Benign0.18Likely Benign0.24Likely Benign0.379Likely Benign-2.27Neutral0.999Probably Damaging0.997Probably Damaging2.00Pathogenic0.10Tolerated0.29580.27850-13.7-69.11
c.1549C>G
L517V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L517V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree that the change is deleterious: pathogenic predictions come from SGM‑Consensus, REVEL, FoldX, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM, while benign predictions are made by SIFT and AlphaMissense‑Optimized; the remaining tools (Rosetta, Foldetta, AlphaMissense‑Default) are uncertain. High‑accuracy assessments further support a pathogenic bias: AlphaMissense‑Optimized predicts benign, SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) is uncertain. Overall, the preponderance of evidence points to a likely pathogenic effect of the variant, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.118441Structured0.147645Uncertain0.9380.2960.000-10.691Likely Pathogenic0.498AmbiguousLikely Benign2.04Destabilizing0.31.37Ambiguous1.71Ambiguous1.14Destabilizing0.577Likely Pathogenic-2.68Deleterious0.998Probably Damaging0.992Probably Damaging-1.26Pathogenic0.17Tolerated0.14050.2398210.4-14.03
c.3124C>A
Q1042K
2D
AIThe SynGAP1 missense variant Q1042K is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates Likely Benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the collective predictions strongly suggest that the variant is most likely benign, and this conclusion does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.969315Disordered0.959333Binding0.3100.8460.625-4.331Likely Benign0.498AmbiguousLikely Benign0.304Likely Benign-1.52Neutral0.224Benign0.091Benign5.44Benign0.13Tolerated0.23380.520211-0.40.04
c.3751C>G
Q1251E
2D
AIThe SynGAP1 missense variant Q1251E is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized, whereas polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. Two tools, ESM1b and AlphaMissense‑Default, return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because it contains two uncertain and two benign calls, and Foldetta data are unavailable. Overall, the balance of evidence leans toward a benign interpretation, and this does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.771762Disordered0.363872Uncertain0.8690.5510.875-7.836In-Between0.499AmbiguousLikely Benign0.183Likely Benign-2.26Neutral0.985Probably Damaging0.981Probably Damaging2.50Benign0.00Affected0.12810.1266220.00.98
c.1279C>G
H427D
2D
3DClick to see structure in 3D Viewer
AISynGAP1 missense variant H427D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, premPS, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, polyPhen‑2 HumVar, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) all indicate benign or likely benign. Only polyPhen‑2 HumDiv predicts a pathogenic outcome. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized scores benign, SGM‑Consensus is likely benign, while Foldetta (combining FoldX‑MD and Rosetta outputs) is inconclusive. No evidence from the available tools suggests pathogenicity, and the absence of a ClinVar classification means there is no contradiction. Therefore, based on the current predictions, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignGAP0.081712Structured0.394261Uncertain0.9620.2870.000-3.684Likely Benign0.500AmbiguousLikely Benign0.76Ambiguous0.11.26Ambiguous1.01Ambiguous0.10Likely Benign0.163Likely Benign-1.43Neutral0.677Possibly Damaging0.236Benign3.58Benign0.12Tolerated0.22410.16781-1-0.3-22.05
c.1285C>T
R429W
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant R429W is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33438190‑C‑T). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions come from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b; premPS and AlphaMissense‑Default are inconclusive. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as benign. Overall, the majority of predictions lean toward a benign impact, and this does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.074921Structured0.390504Uncertain0.9590.2900.000Conflicting 56-33438190-C-T654.03e-5-10.666Likely Pathogenic0.500AmbiguousLikely Benign0.31Likely Benign0.1-0.13Likely Benign0.09Likely Benign0.52Ambiguous0.282Likely Benign-3.19Deleterious1.000Probably Damaging0.990Probably Damaging3.41Benign0.03Affected3.38250.12320.34222-33.630.03252.345.50.00.00.20.1XPotentially PathogenicThe guanidinium group of Arg429, located in an α helix (res. Met414-Glu436), either forms a salt bridge with the carboxylate group of an acidic residue (Asp474, Asp467) or a H-bond with the hydroxyl group of Ser471 in an opposing α helix (res. Ala461-Phe476). In the variant simulations, the indole ring of the Trp429 side chain cannot form ionic interactions with the acidic residues. Although it forms a H-bond with Ser471, the bonding is not as strong as that of arginine. The residue swap could affect the tertiary structure assembly during folding; however, no large-scale negative effects were seen during the simulations.
c.2471G>C
S824T
2D
AIThe SynGAP1 missense variant S824T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports the variant as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Based on the preponderance of evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.728858Disordered0.611272Binding0.3140.8840.750-4.135Likely Benign0.500AmbiguousLikely Benign0.116Likely Benign-0.74Neutral0.992Probably Damaging0.987Probably Damaging2.62Benign0.47Tolerated0.17600.6525110.114.03
c.34A>C
S12R
2D
AIThe SynGAP1 missense variant S12R is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (majority of the four high‑accuracy tools) also indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.490599Uncertain0.3550.9160.500-4.033Likely Benign0.500AmbiguousLikely Benign0.116Likely Benign-0.30Neutral0.000Benign0.000Benign4.09Benign0.00Affected4.3210.09440.36780-1-3.769.11
c.36C>A
S12R
2D
AIThe SynGAP1 missense variant S12R is present in gnomAD (ID 6‑33420300‑C‑A) but has no ClinVar entry. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus score all report benign or likely benign. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign, and the SGM‑Consensus (derived from the majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors benign. Foldetta, a protein‑folding stability predictor, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.490599Uncertain0.3550.9160.5006-33420300-C-A-4.033Likely Benign0.500AmbiguousLikely Benign0.097Likely Benign-0.30Neutral0.000Benign0.000Benign4.09Benign0.00Affected4.3210.09440.36780-1-3.769.11
c.36C>G
S12R
2D
AIThe SynGAP1 missense variant S12R is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33420300‑C‑G). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote). Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors a benign classification; Foldetta’s protein‑folding stability analysis is unavailable. Overall, the majority of evidence points to a benign effect, and this does not contradict the ClinVar “Uncertain” designation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.480142Structured0.490599Uncertain0.3550.9160.500Uncertain 16-33420300-C-G42.59e-6-4.033Likely Benign0.500AmbiguousLikely Benign0.097Likely Benign-0.30Neutral0.000Benign0.000Benign4.09Benign0.00Affected4.3210.09440.36780-1-3.769.11
c.856C>G
L286V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L286V is not reported in ClinVar (ClinVar status: none) and is absent from gnomAD (gnomAD ID: none). Prediction tools that agree on a benign effect include only AlphaMissense‑Optimized, whereas the remaining tools—SGM‑Consensus, REVEL, FoldX, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM—consistently predict a pathogenic impact; AlphaMissense‑Default and Rosetta are uncertain. High‑accuracy methods give a mixed picture: AlphaMissense‑Optimized indicates benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) also predicts pathogenic. Overall, the preponderance of evidence points to a pathogenic effect. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicC20.122885Structured0.385647Uncertain0.9320.2600.000-9.986Likely Pathogenic0.500AmbiguousLikely Benign2.44Destabilizing0.51.63Ambiguous2.04Destabilizing1.26Destabilizing0.676Likely Pathogenic-2.76Deleterious0.999Probably Damaging0.994Probably Damaging1.71Pathogenic0.01Affected0.14920.3007210.4-14.03
c.944A>T
N315I
2D
3DClick to see structure in 3D Viewer
AISynGAP1 variant N315I is not reported in ClinVar and is absent from gnomAD. In silico predictors that agree on a benign effect include REVEL, Rosetta, premPS, SIFT, and AlphaMissense‑Optimized. Predictors that agree on a pathogenic effect are SGM‑Consensus, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. The high‑accuracy AlphaMissense‑Optimized score is benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is pathogenic; Foldetta, which integrates FoldX‑MD (uncertain) and Rosetta (benign), is considered unavailable. Overall, the balance of evidence leans toward pathogenicity, and this assessment does not conflict with the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicC20.118441Structured0.379740Uncertain0.8620.2530.125-9.666Likely Pathogenic0.500AmbiguousLikely Benign-0.72Ambiguous0.4-0.17Likely Benign-0.45Likely Benign0.36Likely Benign0.496Likely Benign-5.19Deleterious1.000Probably Damaging0.999Probably Damaging1.90Pathogenic0.43Tolerated0.07630.7235-2-38.0-0.94
c.1516C>A
L506I
2D
AIThe SynGAP1 missense variant L506I is not reported in ClinVar and is absent from gnomAD. Consensus from standard in‑silico predictors shows a split: benign calls come from REVEL, PROVEAN, and AlphaMissense‑Optimized, whereas pathogenic calls arise from polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM. Uncertain results are reported by FoldX, premPS, and AlphaMissense‑Default. High‑accuracy assessments give a pathogenic verdict from Foldetta (a combined FoldX‑MD/Rosetta stability analysis) and from the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN). AlphaMissense‑Optimized, however, predicts benign. Overall, the majority of reliable tools and the high‑accuracy methods favor a pathogenic effect, and this conclusion does not conflict with the absence of a ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.034884Structured0.279180Uncertain0.9240.1960.000-10.386Likely Pathogenic0.501AmbiguousLikely Benign1.73Ambiguous1.02.85Destabilizing2.29Destabilizing0.98Ambiguous0.365Likely Benign-1.99Neutral0.998Probably Damaging0.997Probably Damaging1.65Pathogenic0.01Affected0.07450.2033220.70.00
c.133A>T
N45Y
2D
AIThe SynGAP1 missense variant N45Y is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic outcome. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized independently predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence—including the high‑accuracy tools—points to a benign impact. This conclusion is consistent with the lack of ClinVar annotation, so there is no contradiction with existing clinical databases.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.401658Structured0.431853Uncertain0.4980.7410.375-5.773Likely Benign0.502AmbiguousLikely Benign0.180Likely Benign-1.18Neutral0.943Possibly Damaging0.924Probably Damaging4.04Benign0.00Affected0.07410.7255-2-22.249.07
c.1931A>C
D644A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 D644A missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that classify the variant as benign include REVEL, FoldX, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, Foldetta, and premPS. Only PROVEAN predicts it as pathogenic, while Rosetta and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign; and Foldetta also predicts benign stability. Based on the aggregate evidence, the variant is most likely benign, and this conclusion does not contradict any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.066181Structured0.248888Uncertain0.8830.3200.000-3.358Likely Benign0.502AmbiguousLikely Benign-0.14Likely Benign0.1-0.83Ambiguous-0.49Likely Benign-0.18Likely Benign0.274Likely Benign-3.90Deleterious0.311Benign0.032Benign3.51Benign0.39Tolerated0.38830.54810-25.3-44.01
c.2617A>T
S873C
2D
AIThe SynGAP1 missense variant S873C is not reported in ClinVar (ClinVar status: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, FATHMM, and AlphaMissense‑Optimized, whereas a majority of tools (PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b) predict a pathogenic impact; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a pathogenic view: AlphaMissense‑Optimized predicts benign, while the SGM Consensus (derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a pathogenic verdict. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the balance of evidence leans toward pathogenicity, and this conclusion does not contradict the ClinVar status, which currently contains no classification for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.414856Structured0.649816Binding0.2830.8660.125-8.293Likely Pathogenic0.502AmbiguousLikely Benign0.224Likely Benign-2.71Deleterious0.999Probably Damaging0.997Probably Damaging2.62Benign0.04Affected0.11240.58870-13.316.06
c.2744G>A
G915D
2D
AIThe SynGAP1 missense variant G915D is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for G915D, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.657645Disordered0.808641Binding0.3020.8800.375-3.409Likely Benign0.502AmbiguousLikely Benign0.134Likely Benign-1.75Neutral0.978Probably Damaging0.871Possibly Damaging2.70Benign0.01Affected0.15740.15591-1-3.158.04
c.523C>G
Q175E
2D
AIThe SynGAP1 missense variant Q175E is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD. Consensus from multiple in‑silico predictors shows a benign bias: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, whereas ESM1b predicts it to be pathogenic. AlphaMissense‑Default remains uncertain. High‑accuracy assessment further supports a benign outcome: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign, and Foldetta stability analysis is unavailable. Consequently, the overall evidence points to a benign effect for Q175E. This conclusion is consistent with the absence of a ClinVar assertion, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.653063Disordered0.474689Uncertain0.3670.6180.375-11.035Likely Pathogenic0.502AmbiguousLikely Benign0.149Likely Benign-0.68Neutral0.118Benign0.039Benign4.17Benign0.40Tolerated0.13510.2028220.00.98
c.739C>A
Q247K
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q247K (PH domain) is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include FoldX, premPS, PROVEAN, SIFT, FATHMM, AlphaMissense‑Optimized, and polyPhen2_HumVar. Tools that predict a pathogenic effect are REVEL, polyPhen2_HumDiv, and ESM1b. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, favors a benign outcome (2 benign vs. 1 pathogenic). High‑accuracy methods all support benignity: AlphaMissense‑Optimized is benign, the SGM Consensus is benign, and Foldetta (combining FoldX‑MD and Rosetta) is benign. Uncertain results from AlphaMissense‑Default and Rosetta are treated as unavailable. Overall, the collective evidence points to a benign impact for Q247K, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
PH0.490133Structured0.283012Uncertain0.8220.3390.250-10.377Likely Pathogenic0.502AmbiguousLikely Benign-0.28Likely Benign0.10.74Ambiguous0.23Likely Benign-0.13Likely Benign0.529Likely Pathogenic-0.44Neutral0.787Possibly Damaging0.351Benign5.89Benign0.13Tolerated0.13660.275811-0.40.04
c.1366C>G
Q456E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant Q456E is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Functional prediction tools that agree on a benign effect include REVEL, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. The remaining tools (FoldX, Rosetta, Foldetta, premPS, AlphaMissense‑Default) yield uncertain or inconclusive results and are treated as unavailable. High‑accuracy assessments show AlphaMissense‑Optimized predicting benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicting pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) remaining uncertain. Overall, the predictions are split, but the high‑accuracy consensus leans toward pathogenicity. Thus, the variant is most likely pathogenic based on current computational evidence, and this assessment does not contradict ClinVar status, as the variant has no ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.170161Structured0.302348Uncertain0.9390.1640.000-12.982Likely Pathogenic0.503AmbiguousLikely Benign0.71Ambiguous0.10.87Ambiguous0.79Ambiguous0.65Ambiguous0.233Likely Benign-2.76Deleterious0.998Probably Damaging0.964Probably Damaging3.41Benign0.15Tolerated0.11910.1276220.00.98
c.2636C>A
A879E
2D
AIThe SynGAP1 missense variant A879E is reported in gnomAD (variant ID 6‑33443188‑C‑A) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. High‑accuracy predictions specifically show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta data is missing. Overall, the majority of evidence points to a benign effect, and this assessment does not contradict any ClinVar status because none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.608892Disordered0.622695Binding0.2770.8740.2506-33443188-C-A16.20e-7-3.786Likely Benign0.503AmbiguousLikely Benign0.070Likely Benign-0.27Neutral0.872Possibly Damaging0.659Possibly Damaging2.70Benign0.27Tolerated3.7750.11200.1903-10-5.358.04
c.28C>T
R10W
2D
AIThe SynGAP1 R10W missense variant is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33420292‑C‑T). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (which itself is “Likely Benign”). Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also indicates benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.534167Disordered0.513657Binding0.3300.9150.625Uncertain 16-33420292-C-T21.30e-6-5.707Likely Benign0.503AmbiguousLikely Benign0.236Likely Benign-0.31Neutral0.964Probably Damaging0.190Benign4.10Benign0.00Affected4.3210.14610.45422-33.630.03
c.3817C>A
L1273M
2D
AIThe SynGAP1 missense variant L1273M is catalogued in gnomAD (ID 6‑33447865‑C‑A) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign, and the Foldetta stability analysis is unavailable. Overall, the majority of evidence points to a benign effect for the variant. This conclusion is not contradicted by ClinVar, as no ClinVar classification exists for this change.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.599170Disordered0.773625Binding0.7470.6770.5006-33447865-C-A-5.375Likely Benign0.503AmbiguousLikely Benign0.161Likely Benign-1.68Neutral0.983Probably Damaging0.874Possibly Damaging2.14Pathogenic0.00Affected3.7750.08240.393224-1.918.03
c.817G>C
E273Q
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant E273Q is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, PROVEAN, and AlphaMissense‑Optimized. Tools that predict a pathogenic outcome are polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as benign. Overall, the majority of individual predictors (seven benign vs. five pathogenic) lean toward a benign classification, while the SGM Consensus and AlphaMissense‑Optimized provide conflicting signals. Thus, the variant is most likely benign based on the aggregate predictions, and this assessment does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.071867Structured0.398918Uncertain0.8630.1960.125-9.865Likely Pathogenic0.503AmbiguousLikely Benign-0.29Likely Benign0.1-0.29Likely Benign-0.29Likely Benign-0.01Likely Benign0.168Likely Benign-1.84Neutral0.946Possibly Damaging0.671Possibly Damaging1.77Pathogenic0.04Affected0.12200.3130220.0-0.98
c.2404G>C
G802R
2D
AIThe SynGAP1 missense variant G802R is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also indicates a likely benign outcome. Only SIFT predicts a pathogenic effect, and AlphaMissense‑Default remains uncertain. High‑accuracy assessments reinforce the benign interpretation: AlphaMissense‑Optimized reports benign, and the SGM‑Consensus (majority vote) likewise predicts likely benign; Foldetta results are unavailable. Overall, the preponderance of evidence supports a benign classification for G802R, and this conclusion does not contradict any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.894241Disordered0.681966Binding0.2940.8980.625-4.756Likely Benign0.504AmbiguousLikely Benign0.072Likely Benign-1.05Neutral0.259Benign0.196Benign2.68Benign0.01Affected0.09950.4514-3-2-4.199.14
c.1291C>G
L431V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 L431V missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, SIFT, FATHMM, AlphaMissense‑Optimized, and polyPhen‑2 HumVar. Those that predict a pathogenic effect are FoldX, premPS, PROVEAN, and polyPhen‑2 HumDiv. Four tools (Rosetta, Foldetta, ESM1b, AlphaMissense‑Default) give uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive due to a 1‑to‑1 split between benign and pathogenic signals, and Foldetta also yields an uncertain outcome. Overall, the balance of evidence—including the higher number of benign predictions and the benign call from the most accurate tool—suggests that the variant is most likely benign. This conclusion does not contradict the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.094817Structured0.374755Uncertain0.9590.3000.000-7.949In-Between0.505AmbiguousLikely Benign2.17Destabilizing0.01.50Ambiguous1.84Ambiguous1.32Destabilizing0.093Likely Benign-2.58Deleterious0.861Possibly Damaging0.332Benign3.04Benign0.20Tolerated0.13770.3198210.4-14.03
c.3236G>A
S1079N
2D
AIThe SynGAP1 missense variant S1079N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority of the high‑accuracy tools) also predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of predictions indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.983887Binding0.3070.9000.750-4.989Likely Benign0.505AmbiguousLikely Benign0.026Likely Benign-0.97Neutral0.001Benign0.001Benign3.93Benign0.00Affected0.12250.465711-2.727.03
c.3599A>C
E1200A
2D
AIThe SynGAP1 E1200A missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The high‑accuracy AlphaMissense‑Optimized score is benign. The SGM Consensus, derived from a majority vote of AlphaMissense‑Default (uncertain), ESM1b (benign), FATHMM (benign), and PROVEAN (pathogenic), is benign. Foldetta results are unavailable. Overall, the balance of evidence (five benign versus four pathogenic predictions, with a benign SGM Consensus and high‑accuracy benign AlphaMissense‑Optimized) indicates that the variant is most likely benign. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.545602Disordered0.458056Uncertain0.8890.5960.250-3.115Likely Benign0.505AmbiguousLikely Benign0.220Likely Benign-2.61Deleterious0.994Probably Damaging0.926Probably Damaging2.72Benign0.02Affected0.29460.45130-15.3-58.04
c.3687A>C
Q1229H
2D
AIThe SynGAP1 missense variant Q1229H is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) predicts pathogenic. Foldetta results are unavailable. Overall, the majority of evaluated predictors (five out of nine) indicate a pathogenic impact, and this conclusion does not contradict any ClinVar annotation because no ClinVar entry exists for this variant. Thus, the variant is most likely pathogenic based on current computational predictions.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.490133Structured0.466729Uncertain0.8650.5440.375-6.215Likely Benign0.505AmbiguousLikely Benign0.219Likely Benign-3.36Deleterious0.998Probably Damaging0.996Probably Damaging1.75Pathogenic0.05Affected0.09480.2494300.39.01
c.3687A>T
Q1229H
2D
AIThe SynGAP1 missense variant Q1229H is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, ESM1b, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts pathogenic. Foldetta results are unavailable. Overall, the majority of evaluated predictors (five out of nine) indicate a pathogenic impact, so the variant is most likely pathogenic. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.490133Structured0.466729Uncertain0.8650.5440.375-6.215Likely Benign0.505AmbiguousLikely Benign0.219Likely Benign-3.36Deleterious0.998Probably Damaging0.996Probably Damaging1.75Pathogenic0.05Affected0.09480.2494300.39.01
c.793A>C
K265Q
2D
3DClick to see structure in 3D Viewer
AISynGAP1 K265Q is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Among standard in‑silico predictors, five tools (REVEL, FoldX, PROVEAN, AlphaMissense‑Optimized, Foldetta) predict a benign effect, while five (polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM) predict pathogenicity. Three tools (premPS, AlphaMissense‑Default, Rosetta) are inconclusive. High‑accuracy assessments give a benign result from AlphaMissense‑Optimized, a pathogenic consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN), and a benign outcome from Foldetta. Overall, the predictions are mixed; the balance of evidence, including the two high‑confidence benign calls, suggests the variant is more likely benign, and this does not contradict the absence of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.209395Structured0.309758Uncertain0.9360.2750.000-8.533Likely Pathogenic0.505AmbiguousLikely Benign0.35Likely Benign0.1-1.15Ambiguous-0.40Likely Benign0.80Ambiguous0.386Likely Benign-2.46Neutral1.000Probably Damaging0.998Probably Damaging1.85Pathogenic0.05Affected0.44010.1062110.4-0.04
c.867G>A
M289I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M289I is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while FoldX and AlphaMissense‑Default are uncertain. High‑accuracy assessments reinforce the benign consensus: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign prediction; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also predicts benign. Overall, the preponderance of evidence indicates that M289I is most likely benign, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.127496Structured0.403499Uncertain0.8860.2760.000-6.010Likely Benign0.505AmbiguousLikely Benign0.62Ambiguous0.1-0.23Likely Benign0.20Likely Benign0.36Likely Benign0.040Likely Benign-0.72Neutral0.005Benign0.018Benign1.78Pathogenic0.31Tolerated0.10010.2758212.6-18.03
c.867G>C
M289I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M289I is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while FoldX and AlphaMissense‑Default are uncertain. High‑accuracy assessments reinforce the benign prediction: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign verdict; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also predicts benign. Overall, the preponderance of evidence indicates that M289I is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.127496Structured0.403499Uncertain0.8860.2760.000-6.010Likely Benign0.505AmbiguousLikely Benign0.62Ambiguous0.1-0.23Likely Benign0.20Likely Benign0.36Likely Benign0.040Likely Benign-0.72Neutral0.005Benign0.018Benign1.78Pathogenic0.31Tolerated0.10010.2758212.6-18.03
c.867G>T
M289I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant M289I is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome, while FoldX and AlphaMissense‑Default are uncertain. High‑accuracy assessments reinforce the benign prediction: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign verdict; and Foldetta, which integrates FoldX‑MD and Rosetta stability outputs, also predicts benign. Overall, the preponderance of evidence indicates that M289I is most likely benign, and this conclusion is consistent with the absence of any ClinVar pathogenic annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.127496Structured0.403499Uncertain0.8860.2760.000-6.010Likely Benign0.505AmbiguousLikely Benign0.62Ambiguous0.1-0.23Likely Benign0.20Likely Benign0.36Likely Benign0.040Likely Benign-0.72Neutral0.005Benign0.018Benign1.78Pathogenic0.31Tolerated0.10010.2758212.6-18.03
c.1298C>A
A433E
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant A433E is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Two tools (premPS and AlphaMissense‑Default) give uncertain results. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign prediction; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, also reports benign. No prediction is missing or inconclusive. Overall, the preponderance of evidence indicates that the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.098513Structured0.352258Uncertain0.9380.3020.000-8.210Likely Pathogenic0.506AmbiguousLikely Benign-0.20Likely Benign0.00.15Likely Benign-0.03Likely Benign0.58Ambiguous0.148Likely Benign-1.65Neutral0.998Probably Damaging0.824Possibly Damaging3.42Benign0.18Tolerated0.07830.16950-1-5.358.04
c.2002T>G
S668A
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 S668A missense variant is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, Rosetta, premPS, SIFT, FATHMM, AlphaMissense‑Optimized, and Foldetta. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Two tools—AlphaMissense‑Default and FoldX—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic. Taking all evidence together, the majority of predictions (seven benign versus four pathogenic) and the two high‑accuracy benign calls suggest that the variant is most likely benign. This conclusion does not contradict ClinVar status, as the variant has no ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.247041Structured0.084935Uncertain0.9220.3700.000-12.011Likely Pathogenic0.506AmbiguousLikely Benign0.73Ambiguous0.3-0.44Likely Benign0.15Likely Benign0.48Likely Benign0.399Likely Benign-2.99Deleterious0.887Possibly Damaging0.738Possibly Damaging3.28Benign0.19Tolerated0.48660.3967112.6-16.00
c.2497A>G
K833E
2D
AIThe SynGAP1 missense variant K833E is evaluated by multiple in silico tools. Benign predictions come from REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions are reported by polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. The AlphaMissense‑Default score is uncertain. The consensus predictor SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus confirms Likely Benign, and Foldetta data are not available. ClinVar contains no entry for this variant, and it is absent from gnomAD, so no external evidence contradicts the computational assessment. Based on the collective predictions, the variant is most likely benign, with no conflict from ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.671169Disordered0.625797Binding0.3150.8630.375-2.495Likely Benign0.506AmbiguousLikely Benign0.108Likely Benign-0.69Neutral0.997Probably Damaging0.925Probably Damaging2.72Benign0.04Affected0.31620.1039010.40.94
c.571A>G
S191G
2D
AIThe SynGAP1 missense variant S191G is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while ESM1b and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also leans toward benign (two benign versus two uncertain). Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the preponderance of evidence indicates that S191G is most likely benign, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.429200Structured0.428475Uncertain0.3220.6150.125-7.161In-Between0.506AmbiguousLikely Benign0.173Likely Benign-2.43Neutral0.131Benign0.058Benign3.77Benign0.03Affected0.28930.5335100.4-30.03
c.3364G>C
G1122R
2D
AIThe SynGAP1 missense variant G1122R is not reported in ClinVar (ClinVar status: not listed) and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, polyPhen‑2 HumVar, and FATHMM, while pathogenic predictions arise from polyPhen‑2 HumDiv, SIFT, and ESM1b; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) resolves to benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence (six benign versus three pathogenic predictions, plus a benign consensus) indicates that the variant is most likely benign, and this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.896620Disordered0.814918Binding0.3570.9320.875-9.063Likely Pathogenic0.507AmbiguousLikely Benign0.319Likely Benign-0.05Neutral0.639Possibly Damaging0.351Benign4.64Benign0.05Affected0.09760.4342-3-2-4.199.14
c.343C>A
Q115K
2D
AIThe SynGAP1 missense variant Q115K is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign interpretation: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict benign, while the majority of other predictors (polyPhen‑2 HumDiv and HumVar) indicate pathogenic. When predictions are grouped by agreement, the benign‑oriented tools outnumber the pathogenic ones, and the single uncertain call from AlphaMissense‑Default does not alter the overall trend. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized classifies the variant as benign, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports it as Likely Benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Based on the preponderance of benign predictions and the high‑accuracy consensus, the variant is most likely benign; this conclusion is consistent with the absence of a ClinVar pathogenic claim.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.784345Disordered0.657256Binding0.3270.8780.750-3.365Likely Benign0.507AmbiguousLikely Benign0.101Likely Benign-0.49Neutral0.924Possibly Damaging0.857Possibly Damaging4.18Benign0.40Tolerated0.17040.367811-0.40.04
c.1046C>A
P349Q
2D
3DClick to see structure in 3D Viewer
AISynGAP1 P349Q is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two groups: benign predictions come from REVEL, SIFT, and AlphaMissense‑Optimized, while pathogenic predictions arise from PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. The remaining tools (FoldX, Rosetta, premPS, AlphaMissense‑Default, Foldetta) give uncertain or inconclusive results. High‑accuracy assessments further clarify the variant’s likely effect: AlphaMissense‑Optimized predicts a benign outcome; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, indicates a pathogenic outcome; and Foldetta, which integrates FoldX‑MD and Rosetta stability calculations, remains uncertain. Overall, the majority of evidence points toward a pathogenic effect, and this conclusion does not conflict with the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicC20.167087Structured0.348607Uncertain0.9470.3960.000-10.545Likely Pathogenic0.508AmbiguousLikely Benign0.98Ambiguous0.11.87Ambiguous1.43Ambiguous0.91Ambiguous0.345Likely Benign-6.40Deleterious1.000Probably Damaging0.997Probably Damaging1.54Pathogenic0.06Tolerated0.14800.47660-1-1.931.01
c.3425C>T
S1142F
2D
AIThe SynGAP1 missense variant S1142F has no ClinVar record and is not present in gnomAD. Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic outcome are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign majority, and Foldetta data are unavailable. Overall, the balance of evidence—especially from the high‑accuracy tools—suggests that the variant is most likely benign. This conclusion does not contradict ClinVar status, as no ClinVar entry exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.919029Disordered0.719935Binding0.2760.8441.000-5.074Likely Benign0.508AmbiguousLikely Benign0.206Likely Benign-3.70Deleterious0.918Possibly Damaging0.827Possibly Damaging2.65Benign0.00Affected0.08610.5603-3-23.660.10
c.377T>A
F126Y
2D
AIThe SynGAP1 missense variant F126Y has no ClinVar entry and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized independently predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar status because no ClinVar classification exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.486429Structured0.712056Binding0.3160.8740.500-3.519Likely Benign0.509AmbiguousLikely Benign0.044Likely Benign-1.29Neutral0.851Possibly Damaging0.221Benign3.90Benign0.00Affected0.16310.190773-4.116.00
c.494G>A
S165N
2D
AIThe SynGAP1 missense variant S165N is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, SIFT, and ESM1b. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also resolves to benign. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, as no ClinVar classification exists for S165N.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.429200Structured0.509123Binding0.3240.6440.250-9.041Likely Pathogenic0.509AmbiguousLikely Benign0.074Likely Benign-0.49Neutral0.532Possibly Damaging0.229Benign4.03Benign0.00Affected0.15890.486211-2.727.03
c.215G>C
R72P
2D
AIThe SynGAP1 missense variant R72P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is classified as Likely Benign. High‑accuracy assessments show AlphaMissense‑Optimized as Benign and the SGM‑Consensus as Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for R72P, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.497853Structured0.455349Uncertain0.3550.8190.375-3.394Likely Benign0.510AmbiguousLikely Benign0.149Likely Benign-0.93Neutral0.841Possibly Damaging0.453Possibly Damaging4.10Benign0.00Affected0.25060.41570-22.9-59.07
c.2446T>C
S816P
2D
AIThe SynGAP1 missense variant S816P is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools cluster around a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign, while the majority of other predictors (polyPhen‑2 HumDiv and HumVar) suggest pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign and the SGM‑Consensus likewise indicates Likely Benign; Foldetta data are unavailable. Overall, the preponderance of evidence points to a benign effect for S816P, and this conclusion is not in conflict with ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.476583Structured0.747189Binding0.3470.8980.375-3.662Likely Benign0.510AmbiguousLikely Benign0.160Likely Benign-0.26Neutral0.999Probably Damaging0.966Probably Damaging2.66Benign0.45Tolerated0.22980.51021-1-0.810.04
c.311G>C
R104P
2D
AIThe SynGAP1 missense variant R104P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.795062Disordered0.678998Binding0.3390.8690.625-3.184Likely Benign0.510AmbiguousLikely Benign0.200Likely Benign-0.88Neutral0.947Possibly Damaging0.410Benign4.01Benign0.00Affected0.17590.44980-22.9-59.07
c.3128G>T
R1043M
2D
AIThe SynGAP1 missense variant R1043M is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Consensus predictions from multiple in‑silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized all predict benign, while polyPhen‑2 HumDiv and SIFT predict pathogenic. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign, and the SGM‑Consensus also indicates Likely Benign; Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign impact for R1043M, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.978672Disordered0.954069Binding0.2990.8530.625-4.800Likely Benign0.510AmbiguousLikely Benign0.471Likely Benign-1.98Neutral0.744Possibly Damaging0.229Benign5.38Benign0.00Affected0.19820.44680-16.4-24.99
c.3287A>C
E1096A
2D
AIThe SynGAP1 missense variant E1096A is listed in ClinVar (ID 2579889.0) with an uncertain significance annotation and is not reported in gnomAD. Consensus from multiple in‑silico predictors shows a predominance of benign calls: REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only polyPhen‑2 HumDiv assigns a pathogenic label, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus also indicates likely benign; Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the aggregate evidence points to a benign effect, which is consistent with the ClinVar uncertain status rather than contradicting it.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.926919Disordered0.976475Binding0.3080.8581.000Uncertain 1-4.504Likely Benign0.510AmbiguousLikely Benign0.164Likely Benign-1.37Neutral0.626Possibly Damaging0.184Benign2.77Benign0.16Tolerated3.7750.38050.7569-105.3-58.04
c.3641G>T
R1214L
2D
AIThe SynGAP1 missense variant R1214L is not reported in ClinVar (ClinVar ID: None) and is absent from gnomAD (gnomAD ID: None). Prediction tools that agree on a benign effect include REVEL, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. Two tools, ESM1b and AlphaMissense‑Default, return uncertain results. High‑accuracy assessments are limited: AlphaMissense‑Optimized classifies the variant as benign, while the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive, and Foldetta data are unavailable. Overall, the majority of available predictions (four pathogenic versus three benign) suggest a pathogenic impact. This conclusion does not conflict with ClinVar, which contains no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.497853Structured0.506868Binding0.9030.5660.375-7.058In-Between0.510AmbiguousLikely Benign0.114Likely Benign-3.65Deleterious0.992Probably Damaging0.828Possibly Damaging2.56Benign0.01Affected0.14970.2988-3-28.3-43.03
c.65G>C
R22T
2D
AIThe SynGAP1 missense variant R22T is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in silico tools show a split: benign calls from REVEL, PROVEAN, polyPhen2_HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized, while pathogenic calls come from polyPhen2_HumDiv and SIFT. The majority‑vote SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, indicates a likely benign effect. High‑accuracy predictors further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus itself is benign; Foldetta predictions are not available. Given the preponderance of benign predictions and the lack of pathogenic evidence, the variant is most likely benign. This assessment aligns with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.538167Disordered0.441505Uncertain0.3770.8910.500-4.079Likely Benign0.510AmbiguousLikely Benign0.146Likely Benign-0.21Neutral0.462Possibly Damaging0.227Benign4.23Benign0.00Affected0.21400.5599-1-13.8-55.08
c.1247T>G
L416R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 L416R missense variant is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. The remaining tools (FoldX, Rosetta, Foldetta, premPS, AlphaMissense‑Default) give uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also leans toward benign, while Foldetta remains uncertain. Overall, the majority of reliable predictors classify the variant as benign, and this conclusion does not contradict the lack of ClinVar annotation. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.104810Structured0.336105Uncertain0.9350.2270.000-8.600Likely Pathogenic0.511AmbiguousLikely Benign0.71Ambiguous0.00.97Ambiguous0.84Ambiguous0.84Ambiguous0.238Likely Benign-2.05Neutral0.999Probably Damaging0.992Probably Damaging3.35Benign0.43Tolerated0.14450.0702-3-2-8.343.03
c.184G>C
D62H
2D
AIThe SynGAP1 missense variant D62H is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic call comes from SIFT. AlphaMissense‑Default remains uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as likely benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, SGM‑Consensus indicates likely benign, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. Based on the collective predictions, D62H is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.425610Structured0.476010Uncertain0.5750.7200.125-5.253Likely Benign0.511AmbiguousLikely Benign0.070Likely Benign-1.53Neutral0.172Benign0.248Benign4.05Benign0.00Affected0.20590.65791-10.322.05
c.3760G>C
E1254Q
2D
AIThe SynGAP1 missense variant E1254Q is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, and AlphaMissense‑Optimized. Tools that agree on a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessment shows AlphaMissense‑Optimized predicts benign, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—favors pathogenic (2 pathogenic vs. 1 benign). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence from both general and high‑accuracy tools points to a pathogenic impact. This conclusion does not contradict ClinVar status, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.657645Disordered0.403242Uncertain0.8860.5550.625-9.041Likely Pathogenic0.511AmbiguousLikely Benign0.207Likely Benign-2.18Neutral0.999Probably Damaging0.996Probably Damaging2.35Pathogenic0.03Affected0.07680.5258220.0-0.98
c.1516C>G
L506V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L506V is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL and AlphaMissense‑Optimized, whereas the majority of other in silico predictors (FoldX, Rosetta, Foldetta, premPS, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and the SGM Consensus) all indicate a pathogenic impact. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized predicts a benign outcome, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) predicts likely pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) predicts pathogenic. Based on the preponderance of pathogenic predictions and the high‑accuracy tools’ results, the variant is most likely pathogenic, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicGAP0.034884Structured0.279180Uncertain0.9240.1960.000-10.220Likely Pathogenic0.512AmbiguousLikely Benign2.61Destabilizing0.23.27Destabilizing2.94Destabilizing1.36Destabilizing0.420Likely Benign-2.98Deleterious0.996Probably Damaging0.992Probably Damaging1.62Pathogenic0.04Affected0.11260.1660210.4-14.03
c.1792C>A
L598I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant L598I is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, Rosetta, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar) and ESM1b. The remaining tools (FoldX, Foldetta, premPS, AlphaMissense‑Default) give uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta as uncertain. Overall, the majority of reliable predictions indicate a benign impact. This conclusion does not contradict the ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.007259Structured0.147872Uncertain0.9530.1540.000-9.396Likely Pathogenic0.512AmbiguousLikely Benign0.80Ambiguous0.00.38Likely Benign0.59Ambiguous0.78Ambiguous0.246Likely Benign-1.96Neutral0.988Probably Damaging0.910Probably Damaging3.47Benign0.10Tolerated0.07920.2000220.70.00
c.2935T>A
F979I
2D
AIThe SynGAP1 missense variant F979I is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy methods reinforce the benign prediction: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign; Foldetta data are missing. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar annotation, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.816150Disordered0.977500Binding0.2740.8890.625-4.053Likely Benign0.512AmbiguousLikely Benign0.163Likely Benign-1.07Neutral0.925Possibly Damaging0.629Possibly Damaging4.19Benign0.06Tolerated0.23680.3009101.7-34.02
c.3706C>A
Q1236K
2D
AIThe SynGAP1 missense variant Q1236K is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized, whereas polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. Two tools—ESM1b and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive because it contains two benign and two uncertain calls, and Foldetta data are unavailable. Overall, the balance of evidence leans toward a benign classification, and this assessment does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.680603Disordered0.567914Binding0.8830.5370.125-7.379In-Between0.512AmbiguousLikely Benign0.142Likely Benign-1.64Neutral0.985Probably Damaging0.981Probably Damaging2.73Benign0.02Affected0.12420.250311-0.40.04
c.392G>C
G131A
2D
AIThe SynGAP1 missense variant G131A is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and SIFT. AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also predicts benign. Foldetta results are unavailable. Overall, the majority of evidence (5 benign vs 3 pathogenic) supports a benign classification. This conclusion does not contradict ClinVar status, as the variant is not yet catalogued there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.429200Structured0.724779Binding0.3020.8910.250-4.891Likely Benign0.512AmbiguousLikely Benign0.138Likely Benign-2.96Deleterious0.620Possibly Damaging0.157Benign3.99Benign0.01Affected0.39810.4814102.214.03
c.317G>A
R106K
2D
AIThe SynGAP1 missense variant R106K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus indicates Likely Benign, and Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign effect for R106K, and this conclusion does not contradict the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.663409Binding0.3450.8620.875-4.312Likely Benign0.513AmbiguousLikely Benign0.150Likely Benign-1.25Neutral0.004Benign0.001Benign3.82Benign0.00Affected0.56020.4129Weaken320.6-28.01
c.3712C>A
Q1238K
2D
AIThe SynGAP1 missense variant Q1238K is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields a benign prediction. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact. This conclusion is not contradicted by ClinVar, which contains no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.562014Disordered0.548882Binding0.8550.5450.250-8.631Likely Pathogenic0.513AmbiguousLikely Benign0.195Likely Benign-1.70Neutral0.985Probably Damaging0.981Probably Damaging2.51Benign0.30Tolerated0.13450.349411-0.40.04
c.3823C>T
R1275W
2D
AIThe SynGAP1 missense variant R1275W is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33447871‑C‑T). Prediction tools that agree on a benign effect include REVEL, FATHMM, and AlphaMissense‑Optimized, whereas a majority (PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b) predict a pathogenic impact; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive due to a split vote (2 pathogenic, 1 benign, 1 uncertain). Foldetta, which would provide a protein‑folding stability estimate, has no available result for this variant. Overall, the balance of evidence leans toward a pathogenic classification, and this assessment does not contradict ClinVar status because no ClinVar claim exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.648219Disordered0.790317Binding0.7230.6970.5006-33447871-C-T31.93e-6-9.895Likely Pathogenic0.513AmbiguousLikely Benign0.161Likely Benign-4.76Deleterious0.999Probably Damaging0.875Possibly Damaging2.51Benign0.00Affected3.7750.12690.2372-323.630.03
c.3982C>G
R1328G
2D
AIThe SynGAP1 missense variant R1328G is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.887230Disordered0.911775Binding0.3600.7620.875-3.470Likely Benign0.513AmbiguousLikely Benign0.076Likely Benign-2.19Neutral0.784Possibly Damaging0.145Benign4.07Benign0.01Affected0.37360.2562-3-24.1-99.14
c.2521G>C
V841L
2D
AIThe SynGAP1 missense variant V841L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Two tools—ESM1b and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive, and Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict ClinVar status, as the variant has no ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.622677Disordered0.616495Binding0.2610.8730.125-7.924In-Between0.514AmbiguousLikely Benign0.157Likely Benign-0.01Neutral0.992Probably Damaging0.989Probably Damaging2.85Benign0.56Tolerated0.08500.423321-0.414.03
c.2521G>T
V841L
2D
AIThe SynGAP1 missense variant V841L is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Two tools—ESM1b and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is inconclusive, and Foldetta results are unavailable. Overall, the balance of evidence favors a benign classification, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.622677Disordered0.616495Binding0.2610.8730.125-7.924In-Between0.514AmbiguousLikely Benign0.157Likely Benign-0.01Neutral0.992Probably Damaging0.989Probably Damaging2.85Benign0.56Tolerated0.08500.423321-0.414.03
c.277C>T
R93W
2D
AIThe SynGAP1 missense variant R93W is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) indicates a likely benign outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact for R93W, and this conclusion does not contradict any ClinVar annotation, as none exists.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.549151Binding0.2900.8740.625-5.652Likely Benign0.514AmbiguousLikely Benign0.094Likely Benign-2.22Neutral0.981Probably Damaging0.257Benign3.96Benign0.00Affected0.14130.38352-33.630.03
c.290A>T
E97V
2D
AIThe SynGAP1 missense variant E97V is listed in gnomAD (ID 6‑33425898‑A‑T) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions come from polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and Foldetta (FoldX‑MD/Rosetta stability assessment) has no available result. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta data is missing. Overall, the majority of evidence points to a benign effect. This conclusion is consistent with the absence of a ClinVar pathogenic classification, so there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.609018Binding0.3400.8670.6256-33425898-A-T16.20e-7-3.743Likely Benign0.514AmbiguousLikely Benign0.124Likely Benign-1.17Neutral0.947Possibly Damaging0.788Possibly Damaging4.07Benign0.00Affected4.3210.10150.8155-2-27.7-29.98
c.1100T>G
L367R
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 L367R missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and ESM1b. Those that predict a pathogenic effect are SIFT, FATHMM, and Rosetta. Tools with uncertain or inconclusive results are FoldX, premPS, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as benign, and Foldetta (combining FoldX‑MD and Rosetta outputs) as pathogenic. Overall, the majority of evidence points to a benign impact, with a minority of pathogenic predictions. The variant’s status is not contradicted by ClinVar, as it is not yet classified there.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.370445Structured0.441805Uncertain0.7900.6570.250-6.527Likely Benign0.515AmbiguousLikely Benign0.68Ambiguous0.46.63Destabilizing3.66Destabilizing0.70Ambiguous0.196Likely Benign-0.39Neutral0.146Benign0.057Benign1.66Pathogenic0.02Affected0.16080.1173-3-2-8.343.03
c.2102C>T
P701L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 P701L missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, Foldetta, premPS, polyPhen‑2 HumVar, SIFT, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and ESM1b. The remaining tools (FoldX, Rosetta, AlphaMissense‑Default) are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as benign. Overall, the majority of predictions (7 benign vs. 3 pathogenic) and the two high‑accuracy benign calls suggest that the variant is most likely benign. This conclusion does not contradict any ClinVar status, as no ClinVar classification exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.074921Structured0.404318Uncertain0.9180.3450.000-10.185Likely Pathogenic0.515AmbiguousLikely Benign1.15Ambiguous0.0-0.68Ambiguous0.24Likely Benign0.12Likely Benign0.116Likely Benign-3.04Deleterious0.642Possibly Damaging0.087Benign3.50Benign0.09Tolerated0.20180.5546-3-35.416.04
c.2327G>T
G776V
2D
AIThe SynGAP1 missense variant G776V is listed in gnomAD (ID 6‑33442485‑G‑T) but has no ClinVar entry. Functional prediction tools cluster into two groups: benign predictions include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Pathogenic predictions come from polyPhen‑2 (HumDiv and HumVar) and SIFT. AlphaMissense‑Default is uncertain, and Foldetta (FoldX‑MD/Rosetta stability assessment) has no result for this variant. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus also indicates a likely benign outcome; Foldetta data are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar status because none is reported.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.377384Structured0.886983Binding0.2960.8880.2506-33442485-G-T-6.541Likely Benign0.515AmbiguousLikely Benign0.180Likely Benign-2.25Neutral0.999Probably Damaging0.998Probably Damaging4.19Benign0.01Affected3.6460.09930.4223-3-14.642.08
c.2375A>C
E792A
2D
AIThe SynGAP1 missense variant E792A is catalogued in gnomAD (ID 6‑33442927‑A‑C) but has no ClinVar submission. Functional prediction tools cluster into two groups: benign (REVEL, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized) and pathogenic (PROVEAN, SIFT). The high‑accuracy AlphaMissense‑Optimized score is benign, and the SGM consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—also favors benign. Foldetta, a protein‑folding stability predictor, has no available result for this residue. Overall, the preponderance of evidence points to a benign effect. This conclusion is consistent with the absence of a ClinVar pathogenic classification; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.974374Disordered0.452261Uncertain0.3520.8960.8756-33442927-A-C16.20e-7-3.248Likely Benign0.515AmbiguousLikely Benign0.060Likely Benign-3.35Deleterious0.000Benign0.001Benign3.92Benign0.01Affected3.6460.45860.7544-105.3-58.04
c.2489C>G
P830R
2D
AIThe SynGAP1 missense variant P830R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also favors a benign outcome. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta, has no available result for this variant. Overall, the majority of reliable predictors and the high‑accuracy consensus indicate a benign impact. This conclusion is not contradicted by any ClinVar annotation, as none exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.590140Disordered0.618152Binding0.3330.8740.500-5.919Likely Benign0.515AmbiguousLikely Benign0.227Likely Benign-3.51Deleterious1.000Probably Damaging0.999Probably Damaging2.72Benign0.00Affected0.12770.29840-2-2.959.07
c.2594C>A
A865D
2D
AIThe SynGAP1 missense variant A865D is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign effect, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.521092Disordered0.626222Binding0.2710.7880.250-4.635Likely Benign0.515AmbiguousLikely Benign0.123Likely Benign-0.57Neutral0.611Possibly Damaging0.346Benign2.71Benign0.36Tolerated0.15630.15600-2-5.344.01
c.47T>C
M16T
2D
AIThe SynGAP1 missense variant M16T is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized scores the variant as benign and the SGM‑Consensus classifies it as likely benign. No Foldetta stability analysis is available for this residue, so folding‑stability evidence is lacking. Overall, the majority of computational evidence indicates that M16T is most likely benign, and this conclusion is consistent with the absence of a ClinVar pathogenic classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.440853Structured0.459925Uncertain0.3460.9080.375-2.060Likely Benign0.515AmbiguousLikely Benign0.065Likely Benign-0.46Neutral0.006Benign0.001Benign4.23Benign0.00Affected0.23850.2545-1-1-2.6-30.09
c.3085C>A
Q1029K
2D
AIThe SynGAP1 missense variant Q1029K is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default remains uncertain, and Foldetta (a protein‑folding stability method combining FoldX‑MD and Rosetta outputs) has no available result for this variant. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign, while Foldetta data is missing. Overall, the majority of evidence points to a benign impact for Q1029K, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.852992Disordered0.995643Binding0.3750.7340.500-3.698Likely Benign0.516AmbiguousLikely Benign0.075Likely Benign-1.18Neutral0.771Possibly Damaging0.482Possibly Damaging2.79Benign1.00Tolerated0.16560.419611-0.40.04
c.501C>A
D167E
2D
AIThe SynGAP1 D167E missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while ESM1b and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive because it receives two benign votes and two uncertain votes, yielding no clear majority. Foldetta, which would provide a protein‑folding stability estimate, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.429200Structured0.502306Binding0.3770.6670.375-7.636In-Between0.516AmbiguousLikely Benign0.067Likely Benign-1.52Neutral0.063Benign0.062Benign4.07Benign0.00Affected0.13920.7144320.014.03
c.501C>G
D167E
2D
AIThe SynGAP1 D167E missense variant is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while ESM1b and AlphaMissense‑Default are uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive because it receives two benign votes and two uncertain votes, yielding no clear majority. Foldetta, which would provide a protein‑folding stability estimate, has no available result for this variant. Overall, the preponderance of evidence points to a benign impact, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.429200Structured0.502306Binding0.3770.6670.375-7.636In-Between0.516AmbiguousLikely Benign0.067Likely Benign-1.52Neutral0.063Benign0.062Benign4.07Benign0.00Affected0.13920.7144320.014.03
c.1076C>A
T359K
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 T359K missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, Foldetta, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are ESM1b and FATHMM. The remaining tools—FoldX, Rosetta, premPS, and AlphaMissense‑Default—return uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) as pathogenic, and Foldetta as benign. Overall, the majority of predictions (seven benign vs. two pathogenic) support a benign classification, and this conclusion does not contradict the lack of ClinVar annotation. Thus, the variant is most likely benign based on current computational evidence.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.281712Structured0.414952Uncertain0.9390.4800.250-10.822Likely Pathogenic0.517AmbiguousLikely Benign-0.65Ambiguous0.10.66Ambiguous0.01Likely Benign0.75Ambiguous0.163Likely Benign-2.23Neutral0.255Benign0.045Benign1.79Pathogenic0.24Tolerated0.16180.34830-1-3.227.07
c.1678G>A
V560M
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 V560M missense variant is listed in ClinVar with an uncertain significance and is present in gnomAD (ID 6-33440730-G-A). Functional prediction tools that agree on a benign effect include FoldX, Foldetta, PROVEAN, SIFT, and AlphaMissense‑Optimized. Those that agree on a pathogenic effect are REVEL, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, and FATHMM. Uncertain predictions come from Rosetta, premPS, and AlphaMissense‑Default. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as benign. Overall, the majority of high‑confidence tools predict a benign impact, with only one consensus pathogenic prediction. Therefore, the variant is most likely benign based on current computational evidence, and this does not contradict the ClinVar uncertain status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.021381Structured0.013872Uncertain0.8530.2040.000Uncertain 26-33440730-G-A159.50e-6-9.598Likely Pathogenic0.517AmbiguousLikely Benign-0.33Likely Benign0.10.88Ambiguous0.28Likely Benign0.72Ambiguous0.520Likely Pathogenic-2.42Neutral0.999Probably Damaging0.863Possibly Damaging-1.25Pathogenic0.14Tolerated3.37350.11610.398021-2.332.06234.9-52.60.00.0-0.10.1XPotentially BenignVal560 is located on the surface at the end of an α-helix (res. Ala533-Val560). The iso-propyl group of Val560 favorably packs against Asp508 of the opposing α-helix (res. Gln503-Glu519). However, in the variant simulations, the bulkier thioether side chain of Met560 does not form equally favorable inter-helix interactions. Regardless, no negative structural effects are observed during the simulations.
c.242T>A
L81Q
2D
AIThe SynGAP1 missense variant L81Q is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 HumDiv and SIFT. AlphaMissense‑Default is uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) classifies the variant as Likely Benign, and AlphaMissense‑Optimized also predicts Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this assessment does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.632174Disordered0.502033Binding0.2910.8780.250-5.055Likely Benign0.517AmbiguousLikely Benign0.052Likely Benign-1.22Neutral0.919Possibly Damaging0.226Benign3.93Benign0.00Affected0.10460.0888-2-2-7.314.97
c.2479A>T
I827F
2D
AIThe SynGAP1 missense variant I827F is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also reports it as likely benign. In contrast, polyPhen‑2 (HumDiv and HumVar) predict a pathogenic impact. The AlphaMissense‑Default score is uncertain, and no Foldetta stability assessment is available. High‑accuracy methods give a benign consensus: AlphaMissense‑Optimized is benign and the SGM‑Consensus is likely benign, with no Foldetta data. Overall, the majority of evidence points to a benign effect, and this is consistent with the lack of ClinVar annotation; there is no contradiction with ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.590140Disordered0.636272Binding0.3830.8840.625-4.799Likely Benign0.517AmbiguousLikely Benign0.155Likely Benign-1.30Neutral0.999Probably Damaging0.996Probably Damaging2.65Benign0.09Tolerated0.04900.230610-1.734.02
c.2507G>T
S836I
2D
AIThe SynGAP1 missense variant S836I is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Consensus from standard in silico predictors shows five tools (REVEL, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, FATHMM, AlphaMissense‑Optimized) predict a benign effect, while two tools (PROVEAN, SIFT) predict pathogenicity. Two additional predictors (ESM1b, AlphaMissense‑Default) return uncertain results. High‑accuracy assessment further indicates a benign prediction from AlphaMissense‑Optimized; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive (one benign, one pathogenic, two uncertain). Foldetta stability analysis is unavailable. Overall, the balance of evidence favors a benign classification, and this conclusion does not conflict with the absence of a ClinVar annotation. Therefore, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.525368Disordered0.634582Binding0.2690.8590.250-7.751In-Between0.517AmbiguousLikely Benign0.149Likely Benign-3.33Deleterious0.057Benign0.053Benign2.51Benign0.03Affected0.07560.5023-1-25.326.08
c.3654G>C
E1218D
2D
AIThe SynGAP1 missense variant E1218D is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors benign, and no Foldetta stability data are available. Overall, the majority of evidence points to a benign effect, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.595080Disordered0.483050Uncertain0.8980.5650.375-3.574Likely Benign0.517AmbiguousLikely Benign0.138Likely Benign-2.42Neutral0.997Probably Damaging0.992Probably Damaging2.30Pathogenic0.00Affected0.14850.2475320.0-14.03
c.3654G>T
E1218D
2D
AIThe SynGAP1 missense variant E1218D is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Functional prediction tools cluster into two groups: benign predictions come from REVEL, PROVEAN, ESM1b, and AlphaMissense‑Optimized, while pathogenic predictions arise from polyPhen‑2 (HumDiv and HumVar), SIFT, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors benign, and no Foldetta stability data are available. Overall, the majority of evidence points to a benign effect, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Coiled-coil0.595080Disordered0.483050Uncertain0.8980.5650.375-3.574Likely Benign0.517AmbiguousLikely Benign0.138Likely Benign-2.42Neutral0.997Probably Damaging0.992Probably Damaging2.30Pathogenic0.00Affected0.14850.2475320.0-14.03
c.71T>A
V24E
2D
AIThe SynGAP1 missense variant V24E is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, the SGM‑Consensus also indicates Likely Benign, and Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this assessment does not contradict any ClinVar status (none is available).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.541878Disordered0.438970Uncertain0.3820.8900.500-3.397Likely Benign0.517AmbiguousLikely Benign0.171Likely Benign-1.73Neutral0.198Benign0.074Benign3.77Benign0.00Affected0.11330.2415-2-2-7.729.98
c.1309C>T
P437S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant P437S is not reported in ClinVar (ClinVar ID: None) but is present in gnomAD (ID 6‑33438214‑C‑T). Prediction tools that agree on a benign effect include REVEL, Rosetta, FATHMM, and AlphaMissense‑Optimized, whereas PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b all predict a pathogenic outcome; the remaining methods (FoldX, Foldetta, premPS, AlphaMissense‑Default) are uncertain and are treated as unavailable evidence. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the balance of evidence favors a pathogenic interpretation. This conclusion is not contradicted by ClinVar, which contains no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.175930Structured0.306196Uncertain0.9210.2980.0006-33438214-C-T21.24e-6-11.964Likely Pathogenic0.518AmbiguousLikely Benign1.14Ambiguous0.0-3.31Stabilizing-1.09Ambiguous0.60Ambiguous0.226Likely Benign-6.60Deleterious1.000Probably Damaging0.996Probably Damaging3.49Benign0.01Affected3.38260.35480.4843-110.8-10.04
c.3437C>A
P1146H
2D
AIThe SynGAP1 missense variant P1146H is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include ESM1b, FATHMM, and AlphaMissense‑Optimized, whereas a majority of tools (REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT) predict a pathogenic impact; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign classification: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a benign outcome (2 benign vs. 1 pathogenic, 1 uncertain). Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the preponderance of evidence points to a pathogenic effect, and this conclusion does not contradict the ClinVar status, which currently has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.919029Disordered0.732173Binding0.4150.8371.000-4.428Likely Benign0.518AmbiguousLikely Benign0.529Likely Pathogenic-4.93Deleterious1.000Probably Damaging0.983Probably Damaging5.46Benign0.00Affected0.16250.45120-2-1.640.02
c.3686A>G
Q1229R
2D
AIThe SynGAP1 missense variant Q1229R is not reported in ClinVar and has no gnomAD entry. Consensus from multiple in‑silico predictors shows a split: benign calls come from REVEL, SIFT, and AlphaMissense‑Optimized, whereas pathogenic calls arise from PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, and FATHMM. The SGM‑Consensus, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, reports a likely pathogenic verdict. High‑accuracy assessments further illustrate this divergence: AlphaMissense‑Optimized predicts benign, while the SGM‑Consensus (majority vote) indicates pathogenic; Foldetta data are unavailable. With five tools favoring pathogenicity versus two supporting benign, the overall prediction leans toward pathogenic. This conclusion is not contradicted by ClinVar, which contains no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicCoiled-coil0.490133Structured0.466729Uncertain0.8650.5440.375-8.998Likely Pathogenic0.518AmbiguousLikely Benign0.282Likely Benign-2.53Deleterious0.994Probably Damaging0.988Probably Damaging1.80Pathogenic0.16Tolerated0.11780.120011-1.028.06
c.3738G>C
K1246N
2D
AIThe SynGAP1 missense variant K1246N is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT uniformly predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the preponderance of evidence from multiple independent predictors points to a benign effect for K1246N, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.750527Disordered0.375382Uncertain0.8870.5640.625-2.506Likely Benign0.518AmbiguousLikely Benign0.125Likely Benign-1.39Neutral0.980Probably Damaging0.721Possibly Damaging2.66Benign0.02Affected0.33160.0940100.4-14.07
c.3738G>T
K1246N
2D
AIThe SynGAP1 missense variant K1246N is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT uniformly predict a pathogenic outcome. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the preponderance of evidence from multiple independent predictors points to a benign effect for K1246N, and this conclusion is not contradicted by any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignCoiled-coil0.750527Disordered0.375382Uncertain0.8870.5640.625-2.506Likely Benign0.518AmbiguousLikely Benign0.122Likely Benign-1.39Neutral0.980Probably Damaging0.721Possibly Damaging2.66Benign0.02Affected0.33160.0940100.4-14.07
c.614T>G
I205S
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 I205S missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, SIFT, FATHMM, AlphaMissense‑Optimized, and polyPhen‑2 HumVar. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and ESM1b. Tools with uncertain or inconclusive results (FoldX, Rosetta, Foldetta, premPS, AlphaMissense‑Default) are treated as unavailable. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta as uncertain. Overall, the majority of available predictions lean toward a benign impact, and this conclusion does not contradict the ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
PH0.264545Structured0.409933Uncertain0.8210.4140.125-8.694Likely Pathogenic0.518AmbiguousLikely Benign1.17Ambiguous0.20.95Ambiguous1.06Ambiguous0.88Ambiguous0.178Likely Benign-2.73Deleterious0.838Possibly Damaging0.368Benign4.12Benign0.24Tolerated0.23460.0800-1-2-5.3-26.08
c.1156G>T
G386W
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant G386W is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Computational predictors that classify the change as benign include REVEL, premPS, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are FoldX, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. High‑accuracy assessments give a benign verdict from AlphaMissense‑Optimized, a benign consensus from the SGM method (majority of the four contributing tools are benign), and a pathogenic result from Foldetta. Uncertain calls from AlphaMissense‑Default and Rosetta are treated as unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not conflict with the lack of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
C20.733139Disordered0.424156Uncertain0.3340.8980.750-10.389Likely Pathogenic0.519AmbiguousLikely Benign6.07Destabilizing5.51.28Ambiguous3.68Destabilizing-0.23Likely Benign0.471Likely Benign-0.85Neutral0.996Probably Damaging0.920Probably Damaging3.90Benign0.00Affected0.10580.4676-7-2-0.5129.16
c.2279T>C
M760T
2D
AIThe SynGAP1 missense variant M760T is reported in gnomAD (ID 6‑33441744‑T‑C) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) also indicates Likely Benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the consensus of available predictions indicates that the variant is most likely benign, and this conclusion is not contradicted by any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.541878Disordered0.893402Binding0.3460.8650.3756-33441744-T-C16.20e-7-2.365Likely Benign0.519AmbiguousLikely Benign0.096Likely Benign-1.56Neutral0.425Benign0.252Benign2.71Benign0.41Tolerated3.9950.25150.2875-1-1-2.6-30.09
c.2982G>C
K994N
2D
AIThe SynGAP1 missense variant K994N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic call comes from SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, SGM‑Consensus confirms a Likely Benign status, and Foldetta data are unavailable. Taken together, the preponderance of evidence indicates that K994N is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.930054Binding0.2890.9120.750-3.724Likely Benign0.519AmbiguousLikely Benign0.011Likely Benign-0.73Neutral0.255Benign0.113Benign4.09Benign0.01Affected0.40100.2376100.4-14.07
c.2982G>T
K994N
2D
AIThe SynGAP1 missense variant K994N is not reported in ClinVar and is absent from gnomAD. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while the only pathogenic call comes from SIFT. AlphaMissense‑Default is uncertain, and the SGM‑Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) reports the variant as Likely Benign. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized predicts benign, SGM‑Consensus confirms a Likely Benign status, and Foldetta data are unavailable. Taken together, the preponderance of evidence indicates that K994N is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.862302Disordered0.930054Binding0.2890.9120.750-3.724Likely Benign0.519AmbiguousLikely Benign0.009Likely Benign-0.73Neutral0.255Benign0.113Benign4.09Benign0.01Affected0.40100.2376100.4-14.07
c.3332A>C
K1111T
2D
AIThe SynGAP1 missense variant K1111T is reported in gnomAD (ID 6‑33443884‑A‑C) but has no ClinVar entry. Consensus from multiple in silico predictors indicates a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM all classify it as benign, and AlphaMissense‑Optimized also predicts benign. No tool predicts pathogenicity; AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports “Likely Benign,” and Foldetta results are unavailable. Based on the collective evidence, the variant is most likely benign, and this conclusion is not contradicted by ClinVar status, which currently has no classification for this change.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.910643Disordered0.921455Binding0.3000.9020.8756-33443884-A-C21.32e-6-4.037Likely Benign0.519AmbiguousLikely Benign0.080Likely Benign-0.90Neutral0.292Benign0.110Benign2.64Benign0.28Tolerated4.3220.22500.4425-103.2-27.07
c.3349G>C
G1117R
2D
AIThe SynGAP1 missense variant G1117R is not reported in ClinVar and is absent from gnomAD. Consensus among most in silico predictors is benign: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, FATHMM, and AlphaMissense‑Optimized all classify the change as tolerated or benign. No tool predicts pathogenicity. Two predictors (ESM1b and AlphaMissense‑Default) return uncertain results, but these do not alter the overall benign consensus. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, the SGM Consensus (derived from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is inconclusive due to a 2‑to‑2 split, and Foldetta data are unavailable. Consequently, the variant is most likely benign, and this assessment does not contradict the absence of a ClinVar entry.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.882776Disordered0.853192Binding0.3230.9140.750-7.132In-Between0.519AmbiguousLikely Benign0.253Likely Benign-0.68Neutral0.006Benign0.008Benign4.62Benign0.08Tolerated0.09370.4542-3-2-4.199.14
c.1746G>C
E582D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant E582D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two consensus groups: a benign group comprising REVEL, premPS, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized, and a pathogenic group containing polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Remaining tools (FoldX, Rosetta, ESM1b, AlphaMissense‑Default) yield uncertain results and are treated as unavailable. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) leans toward benign, and Foldetta indicates no significant destabilization. Consequently, the variant is most likely benign, and this assessment does not contradict the ClinVar status, which currently has no entry for this change.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.102787Structured0.033838Uncertain0.8450.2350.000-7.974In-Between0.520AmbiguousLikely Benign0.57Ambiguous0.20.95Ambiguous0.76Ambiguous0.40Likely Benign0.093Likely Benign-1.63Neutral0.986Probably Damaging0.989Probably Damaging3.22Benign0.27Tolerated0.14810.2236320.0-14.03
c.1746G>T
E582D
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant E582D is not reported in ClinVar and is absent from gnomAD. Functional prediction tools cluster into two consensus groups: a benign group comprising REVEL, premPS, PROVEAN, SIFT, FATHMM, and AlphaMissense‑Optimized, and a pathogenic group consisting of polyPhen‑2 HumDiv and polyPhen‑2 HumVar. Remaining tools (FoldX, Rosetta, ESM1b, AlphaMissense‑Default) yield uncertain results. High‑accuracy assessments further clarify the picture: AlphaMissense‑Optimized predicts benign; the SGM Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, is inconclusive because two of the four inputs are uncertain; Foldetta, which integrates FoldX‑MD and Rosetta outputs, also reports an uncertain stability change. Consequently, the preponderance of evidence points to a benign effect. This conclusion aligns with the absence of a ClinVar assertion, so there is no contradiction with existing clinical data.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.102787Structured0.033838Uncertain0.8450.2350.000-7.974In-Between0.520AmbiguousLikely Benign0.57Ambiguous0.20.95Ambiguous0.76Ambiguous0.40Likely Benign0.093Likely Benign-1.63Neutral0.986Probably Damaging0.989Probably Damaging3.22Benign0.27Tolerated0.14810.2236320.0-14.03
c.3398T>A
I1133N
2D
AIThe SynGAP1 missense variant I1133N is not reported in ClinVar and is absent from gnomAD. Consensus predictions from multiple in‑silico tools cluster around a benign effect: REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized all indicate benign. Pathogenicity is suggested only by polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates Likely Benign; Foldetta stability analysis is unavailable. Overall, the preponderance of evidence points to a benign effect for I1133N, and this conclusion does not conflict with the absence of a ClinVar classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.919029Disordered0.832785Binding0.3160.8920.750-5.887Likely Benign0.520AmbiguousLikely Benign0.290Likely Benign-1.07Neutral0.453Possibly Damaging0.162Benign5.51Benign0.02Affected0.09610.1140-2-3-8.00.94
c.3950G>A
G1317D
2D
AIThe SynGAP1 missense variant G1317D is not reported in ClinVar (ClinVar status: none) but is present in gnomAD (ID 6‑33451824‑G‑A). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, and SIFT. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) yields a benign prediction (2 benign vs. 1 pathogenic, with one uncertain). Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact. This conclusion does not contradict ClinVar, which has no entry for the variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.908098Disordered0.971158Binding0.3850.8790.7506-33451824-G-A-4.860Likely Benign0.520AmbiguousLikely Benign0.081Likely Benign-3.54Deleterious0.588Possibly Damaging0.212Benign4.03Benign0.00Affected3.7750.21150.2859-11-3.158.04
c.1663G>C
V555L
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant V555L is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, Rosetta, premPS, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, and AlphaMissense‑Optimized. Only FATHMM predicts a pathogenic outcome. The remaining tools—FoldX, Foldetta, ESM1b, and AlphaMissense‑Default—return uncertain or inconclusive results. High‑accuracy assessments show AlphaMissense‑Optimized as benign; the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) is unavailable due to a tie between pathogenic and benign calls, and Foldetta is uncertain. Overall, the preponderance of evidence points to a benign effect. This conclusion is consistent with the lack of ClinVar annotation and does not contradict any existing clinical classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.013265Structured0.008218Uncertain0.9430.2250.000-7.816In-Between0.521AmbiguousLikely Benign-1.43Ambiguous0.1-0.14Likely Benign-0.79Ambiguous0.16Likely Benign0.260Likely Benign-0.97Neutral0.025Benign0.015Benign-1.22Pathogenic0.14Tolerated0.10360.295821-0.414.03
c.2309A>T
Q770L
2D
AIThe SynGAP1 missense variant Q770L is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Prediction tools that agree on a benign effect include SGM‑Consensus (Likely Benign), REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized is benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is Likely Benign. No Foldetta stability prediction is available, so it does not influence the assessment. Overall, the majority of evidence points to a benign effect for Q770L, and this conclusion is consistent with the lack of ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.436924Structured0.923732Binding0.3280.8870.250-5.524Likely Benign0.521AmbiguousLikely Benign0.197Likely Benign-2.17Neutral0.095Benign0.030Benign4.14Benign0.01Affected0.07760.6230-2-27.3-14.97
c.2696T>C
I899T
2D
AIThe SynGAP1 missense variant I899T is not reported in ClinVar (ClinVar ID None) but is present in gnomAD (ID 6‑33443248‑T‑C). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict ClinVar status, which currently has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.675549Disordered0.443727Uncertain0.2920.9280.3756-33443248-T-C21.24e-6-2.472Likely Benign0.521AmbiguousLikely Benign0.103Likely Benign-0.25Neutral0.245Benign0.096Benign2.75Benign0.01Affected4.3240.10060.1014-10-5.2-12.05
c.542A>G
H181R
2D
AIThe SynGAP1 missense variant H181R is not reported in ClinVar (ClinVar ID None) and has no entries in gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Only polyPhen‑2 HumDiv predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus likewise indicates Likely Benign; Foldetta results are unavailable. Based on the collective predictions, the variant is most likely benign, and this assessment does not contradict any ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.505461Disordered0.439530Uncertain0.2940.6160.500-3.668Likely Benign0.521AmbiguousLikely Benign0.174Likely Benign-0.11Neutral0.818Possibly Damaging0.188Benign4.35Benign1.00Tolerated0.15850.178220-1.319.05
c.862G>A
D288N
2D
3DClick to see structure in 3D Viewer
AISynGAP1 D288N is listed in ClinVar with an uncertain significance (ClinVar ID 2572204.0) and is present in gnomAD (6‑33437767‑G‑A). Computational predictors are divided: benign calls come from REVEL, FoldX, Rosetta, Foldetta, premPS, and AlphaMissense‑Optimized, while pathogenic calls come from PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as likely pathogenic. Because the majority of high‑accuracy tools predict benign and the overall split of predictions is even, the variant is most likely benign, which does not contradict the ClinVar status of uncertain.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely PathogenicC20.125101Structured0.395525Uncertain0.8730.2610.000Uncertain 16-33437767-G-A21.24e-6-10.535Likely Pathogenic0.521AmbiguousLikely Benign-0.39Likely Benign0.10.01Likely Benign-0.19Likely Benign-0.03Likely Benign0.321Likely Benign-3.73Deleterious0.999Probably Damaging0.997Probably Damaging1.78Pathogenic0.05Affected3.38230.13980.5770120.0-0.98
c.2021C>T
T674I
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant T674I is not reported in ClinVar (ClinVar status: not listed) but is present in gnomAD (ID 6‑33441280‑C‑T). Functional prediction tools cluster into two groups: benign predictions come from REVEL, FoldX, Rosetta, Foldetta, premPS, SIFT, FATHMM, and AlphaMissense‑Optimized; pathogenic predictions come from PROVEAN, polyPhen‑2 HumDiv, and ESM1b (polyPhen‑2 HumVar is benign). AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, Foldetta as benign, and the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict the ClinVar status, which has no entry for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.129801Structured0.109297Uncertain0.5210.3490.0006-33441280-C-T21.24e-6-8.951Likely Pathogenic0.522AmbiguousLikely Benign-0.05Likely Benign0.10.28Likely Benign0.12Likely Benign-0.04Likely Benign0.289Likely Benign-3.18Deleterious0.981Probably Damaging0.444Benign3.46Benign0.11Tolerated3.40240.08980.6945-105.212.05
c.2410G>A
D804N
2D
AIThe SynGAP1 D804N variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN and FATHMM; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus—derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN—leans toward pathogenic. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of conventional tools predict a benign impact, and this assessment does not contradict the lack of ClinVar annotation. Thus, based on the current predictions, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
SH3-binding motif0.801317Disordered0.786762Binding0.2940.9000.625-4.681Likely Benign0.522AmbiguousLikely Benign0.104Likely Benign-2.62Deleterious0.400Benign0.212Benign1.22Pathogenic0.06Tolerated0.15280.7393210.0-0.98
c.268G>C
V90L
2D
AIThe SynGAP1 missense variant V90L is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Functional prediction tools largely agree on a benign effect: REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized all classify the change as benign, while SIFT uniquely predicts it as pathogenic. The consensus from the SGM framework, which aggregates AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, yields a Likely Benign verdict. High‑accuracy assessments reinforce this view: AlphaMissense‑Optimized reports a benign outcome, the SGM Consensus also indicates Likely Benign, and Foldetta data are unavailable. With the majority of evidence pointing to a benign effect and no conflicting ClinVar annotation, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.570702Disordered0.542047Binding0.3430.8730.500-3.676Likely Benign0.522AmbiguousLikely Benign0.056Likely Benign-0.24Neutral0.103Benign0.015Benign4.02Benign0.00Affected0.13340.448721-0.414.03
c.268G>T
V90L
2D
AIThe SynGAP1 missense variant V90L is not reported in ClinVar and has no entries in gnomAD, indicating it is not catalogued in these databases. Prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), ESM1b, FATHMM, and AlphaMissense‑Optimized. Only SIFT predicts a pathogenic outcome, while AlphaMissense‑Default remains uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts Benign, SGM‑Consensus indicates Likely Benign, and Foldetta results are unavailable. Overall, the preponderance of evidence points to a benign effect for V90L, and this conclusion does not contradict any ClinVar status, as none is assigned.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.570702Disordered0.542047Binding0.3430.8730.500-3.676Likely Benign0.522AmbiguousLikely Benign0.056Likely Benign-0.24Neutral0.103Benign0.015Benign4.02Benign0.00Affected0.13340.448721-0.414.03
c.2735C>T
T912I
2D
AIThe SynGAP1 missense variant T912I is listed in gnomAD (ID 6‑33443287‑C‑T) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain, and Foldetta (FoldX‑MD/Rosetta stability assessment) has no available result for this variant. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta data is missing. Overall, the majority of reliable predictors indicate a benign effect, and this is consistent with the absence of a ClinVar pathogenic classification. Thus, the variant is most likely benign, with no contradiction to ClinVar status.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.724957Disordered0.740671Binding0.2850.9090.2506-33443287-C-T21.24e-6-4.461Likely Benign0.522AmbiguousLikely Benign0.117Likely Benign-1.27Neutral0.999Probably Damaging0.977Probably Damaging3.95Benign0.00Affected3.7750.09450.5615-105.212.05
c.3376G>C
G1126R
2D
AIThe SynGAP1 missense variant G1126R is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. Two tools—ESM1b and AlphaMissense‑Default—return uncertain results. High‑accuracy assessments show AlphaMissense‑Optimized as benign, while the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) is uncertain due to a 2‑to‑2 split between benign and uncertain calls; Foldetta’s protein‑folding stability analysis is unavailable. Overall, the balance of evidence leans toward a benign interpretation, and this conclusion does not contradict any ClinVar annotation because no ClinVar record exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.894241Disordered0.837209Binding0.3450.9180.875-7.760In-Between0.522AmbiguousLikely Benign0.345Likely Benign-0.56Neutral0.971Probably Damaging0.597Possibly Damaging4.77Benign0.01Affected0.09460.4532-3-2-4.199.14
c.1447A>G
I483V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 missense variant I483V is listed in ClinVar with an uncertain significance and is not reported in gnomAD. Functional prediction tools show mixed results: benign predictions come from REVEL, Rosetta, PROVEAN, FATHMM, and AlphaMissense‑Optimized, while pathogenic predictions are reported by premPS, polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b. Predictions marked as uncertain include FoldX, Foldetta, and AlphaMissense‑Default. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, the SGM Consensus (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also yields benign, whereas Foldetta remains uncertain. Overall, the balance of evidence from both general and high‑accuracy tools leans toward a benign effect, which does not contradict the ClinVar designation of uncertain significance.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
GAP0.206376Structured0.415850Uncertain0.7980.2540.000Conflicting 2-10.121Likely Pathogenic0.523AmbiguousLikely Benign1.00Ambiguous0.00.27Likely Benign0.64Ambiguous1.02Destabilizing0.228Likely Benign-0.86Neutral0.914Possibly Damaging0.921Probably Damaging3.23Benign0.03Affected3.37320.08760.269134-0.3-14.03
c.192A>G
I64M
2D
AIThe SynGAP1 missense variant I64M is listed in gnomAD (ID 6‑33425800‑A‑G) but has no ClinVar entry. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 HumVar, ESM1b, FATHMM, AlphaMissense‑Optimized, and the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN). Tools that predict a pathogenic outcome are polyPhen‑2 HumDiv and SIFT, while AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence points to a benign impact, and this conclusion does not contradict any ClinVar status (none reported).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.422041Structured0.475481Uncertain0.4780.7470.1256-33425800-A-G21.24e-6-4.327Likely Benign0.523AmbiguousLikely Benign0.047Likely Benign-0.05Neutral0.637Possibly Damaging0.047Benign4.04Benign0.00Affected4.3210.05680.231012-2.618.03
c.2606T>C
L869P
2D
AIThe SynGAP1 missense variant L869P is not reported in ClinVar (no ClinVar ID) and is absent from gnomAD (no gnomAD ID). Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. AlphaMissense‑Default remains uncertain. The high‑accuracy consensus from SGM (majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) yields a “Likely Benign” classification, and AlphaMissense‑Optimized independently predicts benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the majority of evidence—including the high‑accuracy tools—supports a benign interpretation. This conclusion does not contradict ClinVar status, as no ClinVar assertion exists for this variant.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.501700Disordered0.688653Binding0.2720.8390.250-2.394Likely Benign0.523AmbiguousLikely Benign0.174Likely Benign-0.99Neutral0.990Probably Damaging0.900Possibly Damaging2.58Benign0.04Affected0.36870.1503-3-3-5.4-16.04
c.3127A>T
R1043W
2D
AIThe SynGAP1 missense variant R1043W is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, ESM1b, FATHMM, and AlphaMissense‑Optimized. Those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, and SIFT. AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN) also yields a benign prediction; Foldetta results are unavailable. Overall, the majority of high‑confidence tools predict a benign impact, and there is no ClinVar annotation to contradict this assessment. Thus, the variant is most likely benign.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.978672Disordered0.954069Binding0.2990.8530.625-6.382Likely Benign0.523AmbiguousLikely Benign0.444Likely Benign-3.43Deleterious0.971Probably Damaging0.729Possibly Damaging5.38Benign0.00Affected0.14030.36962-33.630.03
c.3232G>C
V1078L
2D
AIThe SynGAP1 missense variant V1078L is not reported in ClinVar and is absent from gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, also indicates a likely benign classification. High‑accuracy assessments further support this: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus (majority vote) is likely benign. Foldetta results are unavailable, so they do not influence the assessment. Overall, the collective evidence strongly suggests that V1078L is most likely benign, and this conclusion is not contradicted by any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.882776Disordered0.986989Binding0.2940.8980.750-2.547Likely Benign0.523AmbiguousLikely Benign0.091Likely Benign-0.16Neutral0.451Benign0.209Benign4.13Benign0.56Tolerated0.08890.534921-0.414.03
c.464G>C
S155T
2D
AIThe SynGAP1 missense variant S155T is not reported in ClinVar (ClinVar ID = None) and is absent from gnomAD (gnomAD ID = None). Prediction tools that agree on a benign effect include REVEL, PROVEAN, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are polyPhen‑2 (HumDiv and HumVar), SIFT, and ESM1b; AlphaMissense‑Default is uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, and the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) also favors a benign outcome. Foldetta, a protein‑folding stability method, has no available result for this variant. Overall, the majority of reliable predictors and the consensus analysis indicate that S155T is most likely benign, and this conclusion does not contradict any ClinVar annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.497853Structured0.515359Binding0.2920.7870.500-8.635Likely Pathogenic0.523AmbiguousLikely Benign0.153Likely Benign-1.60Neutral0.956Probably Damaging0.931Probably Damaging3.84Benign0.00Affected0.11510.5694110.114.03
c.608A>T
D203V
2D
3DClick to see structure in 3D Viewer
AIThe SynGAP1 D203V missense variant is not reported in ClinVar (ClinVar ID None) and is absent from gnomAD (gnomAD ID None). Prediction tools that agree on a benign effect include REVEL, FoldX, Rosetta, Foldetta, premPS, FATHMM, and AlphaMissense‑Optimized, while those that predict a pathogenic effect are PROVEAN, polyPhen‑2 HumDiv, polyPhen‑2 HumVar, SIFT, and ESM1b; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta (combining FoldX‑MD and Rosetta outputs) as benign. Overall, the majority of tools and the SGM Consensus lean toward a pathogenic interpretation, whereas two high‑accuracy methods (AlphaMissense‑Optimized and Foldetta) suggest benign. Because ClinVar contains no entry for this variant, there is no contradiction between the predictions and existing clinical annotation.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
PH0.314870Structured0.427620Uncertain0.7400.4070.125-10.660Likely Pathogenic0.523AmbiguousLikely Benign0.32Likely Benign0.00.44Likely Benign0.38Likely Benign0.05Likely Benign0.289Likely Benign-4.07Deleterious0.991Probably Damaging0.781Possibly Damaging3.98Benign0.02Affected0.05340.4084-2-37.7-15.96
c.2434C>A
P812T
2D
AIThe SynGAP1 missense variant P812T is not reported in ClinVar and is absent from gnomAD. Prediction tools that agree on a benign effect include REVEL, PROVEAN, ESM1b, FATHMM, and AlphaMissense‑Optimized, while polyPhen‑2 (HumDiv and HumVar) and SIFT all predict a pathogenic impact. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign outcome: AlphaMissense‑Optimized predicts Benign, and the SGM‑Consensus likewise indicates Likely Benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign effect, and this conclusion does not contradict any ClinVar annotation (none exists).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely BenignSH3-binding motif0.414856Structured0.842442Binding0.3880.9010.125-6.956Likely Benign0.524AmbiguousLikely Benign0.105Likely Benign-1.50Neutral0.994Probably Damaging0.927Probably Damaging2.73Benign0.04Affected0.14130.61140-10.93.99
c.3053C>T
T1018I
2D
AIThe SynGAP1 missense variant T1018I is listed in ClinVar with an “Uncertain” status and is present in gnomAD (ID 6‑33443605‑C‑T). Prediction tools that agree on benign impact include REVEL, polyPhen‑2 HumVar, ESM1b, and AlphaMissense‑Optimized, while those that predict pathogenicity are PROVEAN, polyPhen‑2 HumDiv, SIFT, and FATHMM; AlphaMissense‑Default remains uncertain. High‑accuracy assessments show AlphaMissense‑Optimized as benign, the SGM Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) as pathogenic, and Foldetta results are unavailable. Overall, the predictions are split, with no clear majority leaning toward either benign or pathogenic. Thus, the variant’s impact remains inconclusive, and this uncertainty aligns with ClinVar’s current “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
0.849326Disordered0.959985Binding0.3480.8010.500Uncertain 16-33443605-C-T42.48e-6-3.264Likely Benign0.524AmbiguousLikely Benign0.076Likely Benign-2.55Deleterious0.586Possibly Damaging0.304Benign2.24Pathogenic0.01Affected3.7750.10220.4776-105.212.05
c.346T>G
Y116D
2D
AIThe SynGAP1 missense variant Y116D is not reported in ClinVar and is absent from gnomAD, indicating no known population frequency data. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, polyPhen‑2 (HumDiv and HumVar), SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. No tool predicts a pathogenic outcome; AlphaMissense‑Default is uncertain. The SGM‑Consensus, derived from a majority vote of AlphaMissense‑Default, ESM1b, FATHMM, and PROVEAN, classifies the variant as Likely Benign. High‑accuracy assessments further support a benign interpretation: AlphaMissense‑Optimized predicts benign, and the SGM‑Consensus likewise indicates Likely Benign. Foldetta, a protein‑folding stability method combining FoldX‑MD and Rosetta outputs, has no available result for this variant. Overall, the consensus of available predictions strongly suggests that Y116D is most likely benign, and this conclusion does not contradict any ClinVar annotation (none is present).

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.661982Disordered0.670235Binding0.3810.8780.6250.542Likely Benign0.524AmbiguousLikely Benign0.302Likely Benign-0.14Neutral0.000Benign0.001Benign4.24Benign0.83Tolerated0.46030.0545-4-3-2.2-48.09
c.3502A>G
I1168V
2D
AIThe SynGAP1 missense variant I1168V is listed in ClinVar (ID 936001.0) with an “Uncertain” status and is not reported in gnomAD. Functional prediction tools that agree on a benign effect include REVEL, PROVEAN, SIFT, ESM1b, FATHMM, and AlphaMissense‑Optimized. Tools that predict a pathogenic effect are PolyPhen‑2 HumDiv and PolyPhen‑2 HumVar. AlphaMissense‑Default is uncertain, while the SGM‑Consensus (majority vote from AlphaMissense‑Default, ESM1b, FATHMM, PROVEAN) reports a “Likely Benign” outcome. High‑accuracy assessments show AlphaMissense‑Optimized as benign and the SGM‑Consensus as likely benign; Foldetta results are unavailable. Overall, the majority of evidence points to a benign impact, and this consensus does not contradict the ClinVar “Uncertain” classification.

Disclaimer: This summary was generated using AI and should be interpreted alongside expert review.
Likely Benign0.642678Disordered0.763262Binding0.4230.7960.500Uncertain 1-3.263Likely Benign0.524AmbiguousLikely Benign0.363Likely Benign-0.14Neutral0.876Possibly Damaging0.643Possibly Damaging5.47Benign0.84Tolerated3.8830.13390.437443-0.3-14.03

Found 8751 rows. Show 800 rows per page. Page 5/11 « Previous | Next »